FLEXIBLE INTELLIGENT RACK POWER DISTRIBUTION. Contact. About Anord Mardix.

Similar documents
Zenith Series DPB Distributed Power Busway

Zenith Series DPB. Distributed Power Busway

MODULAR CIRCUIT MONITORING SYSTEM

PDI Modular Compact Remote Power Panel

PowerPak 2 Power Distribution Unit. Flexible. Configurable. Intelligent. Safe.

ArmorConnect Power and Control Media

NT-2300 Series Dual Circuit Track System & Accessories

SECTION SWITCHBOARDS

The Different Types of AC Power Connectors in North America

NEW Titan II A & B Distribution Boards

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Configurable power distribution

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

1492-SP Supplementary Protectors

Innovation for MV distribution

SECTION ( ) LIGHTING CONTROL PANELBOARD

PLUG-IN UNITS Table of Contents GM100/GM100G/GM100NG/GM225/ GM400/GM400G/GM400N/GM400NG/GM800

for a perfect electrical installation. The range of rail-mounted terminal blocks

These specifications describe requirements for a power distribution unit (PDU) distributing power to sensitive loads.

Model DMX24DIM Installation and Operations Manual

POWER CABLES FOR MISSION CRITICAL FACILITIES

EnerSure Installation Guide

High-density multi-pin connectors

Switch rated plugs and receptacles with NEMA 4X protection

Specification Sheet: HT SERIES

PowerLogic High Density Metering System 1-Meter Enclosure

IT power distribution Power distribution units (PDU) Basic. Versions available:

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

SPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120

SUNCLIX Connection technology for photovoltaics

US Catalog July 2016 SMISSLINE TP

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

Key Topic. Three Phase UPS Systems

Product Brochure. Series 70 erpp-fs. Web-Enabled Remote Power Panel

Revolutionizing control wiring

TP&N DISTRIBUTION BOARD TYPE B RANGE

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Compact plugs and receptacles standard or high temperature rated

Miniature Circuit Breakers and Supplementary Protectors. Contents

Product Brochure. Eaton epdu G3 Managed

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)

Product Brochure. Eaton epdu G3 Managed

The Foundation Layer. Series 70 erpp-fs. Web-Enabled Remote Power Panel. Product Brochure

SECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].

US CATALOG SMISSLINE TP

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

Connectors DIN 41612/IEC

SACE Emax 2 Specification guide

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution Architecture

High-density multi-pin connectors

Product brochure. Cyberex. Remote Power Panel (RPP) Power distribution system

Rack- and Panel-Mount Power Distribution Units (PDUs)

60103 Circuit Breaker

WIRELESS ENVIRONMENTAL MONITORS

Data Center Integrated solutions

Data Center Integrated solutions

Powering innovation. Powering efficiency. Powering home

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Technical data: Pin Spacing

Isobar UL 1363 Hospital-Grade 6-Outlet Surge Protector, 15 ft. Cord, 3330 Joules, LEDs, Not For Patient-Care Vicinities

Advantys ETB. DATA SHEET Advantys ETB IP 67 Ethernet Digital I/O Modules. Description. Features

Zenith Series MDU & RDU. Critical Power Distribution Units

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

ABB DATA CENTER FORUM 2017, 11 JULY 2017, TUESDAY Remote Power Panels with unique power density - giving you more in less space Nico Ninov, Market

Two Circuit Track Power System IS24 / IS26 / IS28

CS8 Industrial Control Relays

SENTRON 3VL Molded Case Circuit Breakers

Haworth Power Technical Sheets January 2018

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

TeSys IEC Contactors and Overload Relays

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

TABLE OF CONTENTS. IEC and IEC Pin and Sleeve Devices. IEC and IEC Mechanical Interlocks. Manual Disconnect Switches

Rack- and Panel-Mount Power Distribution Units (PDUs)

Posi-Lok Plugs and Panels

Power Base AI. Power Base AI. Technical Sheets

PLPC905GL-3-KNX / PLPC905GL-3-HD-KNX / PLPC905GL-4-KNX / PLPC905GL-4-HD-KNX LightMaster Dimmer Actuator

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

Isobar Surge Suppressors by Tripp-Lite (Most Popular Models)

2013 ESL Power Systems, Inc. All Rights Reserved.

Allen-Bradley 1492-RCDA4A40

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BSPD Surge Protective Devices

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

Pan assemblies and installation accessories

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Transcription:

Contact Anord Mardix (USA) Inc. 3930 Technology Court Sandston, VA 23150 Email: us.sales@anordmardix.com Call: +1 800 228 4689 www.linkedin.com/company/anordmardix www.twitter.com/anordmardix About Anord Mardix Anord Mardix is a leading provider of power distribution and protection equipment to the global market. We are a vendor of choice to many of the world s leading data center and cloud computing industries. We produce the most comprehensive product range in the market - from power, control, and monitoring solutions to our unique service capability. Our ability to customize and produce on a large scale delivers the most reliable end-to-end power systems to all our customers, from independent providers to hyper-scale leaders. FLEXIBLE INTELLIGENT RACK POWER DISTRIBUTION MADE IN THE USA

Optional Wired or Wireless Class 1 Metering Actuator Interlock Intelligent Data Hall Busway Plug-n-play Extensibility The Databar busway system is a unique open channel modular busway system designed for mission critical rack power distribution in data centers. The system has been developed to be extremely compact and features patent pending design innovations in the integral plug-n-play coupling system. This allows for simpler and faster installation and tap-off actuator mechanisms that put safety at the forefront. Thermal Imaging Grids Wide Range of Connectors or Flying Leads Data center operators can rest assured that they not only have the ability to add tap-offs as needed, but also easily extend or reconfigure the busway system over their evolving white space. Databar benefits from over fifty years of design and engineering expertise and its seamless integration with IBAR busbar trunking systems and power management systems delivers a complete package solution. Safety in Simplicity Safe and simple were at the heart of Databar s development which is why there are only two sizes that cover all ratings, one size for 160A - 400A and a second for 600A - 800A. In each size, the same low profile housing accommodates both 4 and 5 pole configurations while still maintaining the smallest possible footprint design. Installing or extending the busway requires no separate joint pack. Fully factory tested busway assemblies feature custom integrated connectors that provide true plug-n-play functionality. Easy Installation Tap-off fitting is carried out in two simple steps. First, the tap-off box is installed on the busway using our fast fit system. Second, the power contacts are engaged via a unique connection actuation system which not only controls the tap-off contacts, but also interlocks with the switching device to ensure that no load is connected during the engage operation. Compact Design Databar s market leading range of tap-offs are extremely compact and, thanks to the small form factor busway design and actuation system, only require 1.2 of mounting clearance - the smallest in the industry! Databar s combination of compact tap-off design and plug-n-play open-channel busway delivers a highly flexible solution to meet the needs of high density, mission critical, over-rack power distribution. The compact design goes a long way towards optimizing over rack space utilization where low ceiling head height and IT / fiber conduits compete. Testing & Certification The Databar product has undergone extensive testing which has been independently certified by Underwriters Laboratories in accordance with UL857. Additionally, the busbar trunking system has been independently tested for resistance to Arc Flash in accordance with IEEE 1584 and major seismic events in accordance with IEEE Std 344-2013 & IEC 60068-3-3 (Richter magnitude 7.0-7.9). Features Independently tested and listed by Underwriters Laboratories to UL857 160, 250, 400, 600 or 800A systems with 4 or 5 poles in the same footprint design Continuous open channel permits tap-offs to be installed anywhere along the bar (Finger Safe, IP2X) Ships in standard lengths up to 10ft (3m) Integral plug-n-play jointing system with miniature busway joint zone (no separate joint parts) Optional over-rated neutrals (see Technical Overview) or 100% integral ground conductor 100% ground path via one piece extruded aluminium housing (see Technical Overview) 600A & 800A 160A, 250A & 400A 3.5in 1.9in 6.5in 1.2 inches Mounting Clearance Integral Comms Channel Copper Conductor Aluminium Housing (100% Case Ground) 1 2

UNIQUE INTEGRAL COUPLING SYSTEM

Technical Overview 5 Installation and Busway Accessories Installation Busway is typically suspended on drop rods from supporting T-slot ceilings or Uni-strut style support hardware. Three hangers are supplied with each length. Our team of installers can offer a one-stop-shop for install, testing (including load bank testing), commissioning, and power management systems integration. Alternative underfloor or server rack-top supports are also available to meet project specific requirements. End Caps Cable End Feeds Each length of busway is terminated with an end cap. If there is a later requirement to extend or reduce the busway this end cap can be removed and re-fitted to the end of the run. Male and female end caps allow for left or right hand fed systems. Channel Closure Strip is a clip in cover supplied in 10ft (3m) lengths, and is typically cut to length on-site and provides a blanking cover to the open channel busway. It can be fitted between tap-offs or across unutilized lengths. Comms Channel Cover clips on to the housing to retain Ethernet cables in wired metering applications. Supplied in 10ft (3m) lengths with options to color code for different power streams. Busway is typically fed by cable from switchboards or high power busbar tap-offs. End feeds accommodate cable terminations and can be configured to left hand or right hand feed locations. Optional end-feed metering, indication or integral switch isolators are available to meet the specific project requirements. Other customization options include custom RAL colors and pre-punched glanding plates to suit specific cable requirements. Elbows The vast majority of installations are straight runs, but, where there is a requirement to change direction, the system can employ elbows in left and right 90 degree angles as standard. Combinations of elbows can be used to circumnavigate building supports. Breaks in runs can also be engineered with cable connections between end feed units. Specification System Ratings System ampacity A 160 250 400 600* 800* Operating voltage V Up to 600V Frequency Hz 50/60 Hz Degree of protection Casing material Conductor material Finger Safe (IP2X) Aluminium Copper Conductor finish Plain (Plated Opt.) Plated Short Circuit Current Rating (unprotected) 42 kaic up to 208VAC** 50 kaic up to 600VAC Case overall dimensions (4P & 5P) Phase Conductor CSA Neutral Conductor CSA Isolated Ground Conductor CSA Housing CSA (Ground) System Weight (4 pole) System Weight (5 pole) 35 kaic up to 600VAC Dimensions 160 250 400 600* 800* in 6.5 x 1.9 6.5 x 1.9 6.5 x 1.9 6.5 x 3.5 6.5 x 3.5 mm 165 x 47 165 x 47 165 x 47 165 x 90 165 x 90 in2 0.3 0.3 0.3 0.8 0.8 mm2 194 194 194 514 514 in2 0.3 0.3 0.3 0.8 0.8 mm2 194 194 194 514 514 in2 0.3 0.3 0.3 0.8 0.8 mm2 194 194 194 514 514 in2 2.26 2.26 2.26 4.94 4.94 mm2 1457 1457 1457 3189 3189 lbs/ft 8.7 8.7 8.7 19.6 19.6 kg/m 12.9 12.9 12.9 29.1 29.1 lbs/ft 9.7 9.7 9.7 22.9 22.9 kg/m 14.5 14.5 14.5 34.1 34.1 System Configurations Ampacity Phase configuration Total No. Poles Phases [3 Poles] Neutral [No. Poles] Ground 160 TP/N 4 100% 100% [1] 100% Case TP/1.5N 4 100% 150% [1] 100% Case TP/2N 4 100% 200% [1] 100% Case TP/E 4 100% - 100% Isolated TP/N/E 5 100% 100% [1] 100% Isolated TP/1.5N/E 5 100% 150% [1] 100% Isolated TP/2N/E 5 100% 200% [1] 100% Isolated 250 TP/N 4 100% 100% [1] 100% Case TP/1.5N 4 100% 150% [1] 100% Case TP/2N 5 200% [2] 100% Case TP/E 4 100% - 100% Isolated TP/N/E 100% 100% [1] 100% Isolated TP/1.5N/E 5 100% 150% [1] 100% Isolated 400 TP/N 4 100% 100% [1] 100% Case 600* & 800* TP/1.5N 4 150% [2] 100% Case TP/2N 5 100% 200% [2] 100% Case TP/E 4 100% - 100% Isolated TP/N/E 5 100% 100% [1] 100% Isolated TP/N 4 100% 100% [1] 100% Case TP/1.5N 4 100% 150% [2] 100% Case TP/2N 5 100% 200% [2] 100% Case TP/E 4 100% - 100% Isolated TP/N/E 5 100% 100% [1] 100% Isolated Case refers to aluminium casing used as ground. Isolated refers to internal insulated pole for ground. *Available Q4 2018, all values TBC. **Option to upgrade to 42kA, standard rating is 35kA 6

SINGLE TAP-OFF RANGE FOR 160A TO 800A

Tap-offs Example Tap-off - Single Pole 30A MCB with Straight IEC 309 Receptacle Databar tap-offs have been designed for simple and safe installation. The range includes unique features which have been developed to vastly improve speed and ease of installation. Front View Side View Tap-off units can be installed on the busway in just a few seconds using the fast fit system - a unique tool free mounting mechanism. The units are available with a range of devices including MCBs and MCCBs. The standard range employs MCBs and these are typically available in 10, 14, 22 and 50kAIC variants in ratings of 15, 20, 30, 50 and 60A and in Single Pole (SP), Double Pole (DP) and Triple Pole (TP); either with or without metering. Outlet connector options include: Panel mounted straight or angled IEC 309 receptacles NEMA Twist Lock and straight blade receptacles Drop cords / flying leads terminated with the required coupler Tap-off Installation Overview The tap-off actuator cannot be operated without the tap-off first being mounted on the busway. This feature works in combination with the switching device interlock which is fitted as standard. The interlock prevents the switching device(s) from being turned on before installation / actuation. Both the tap-off and busway have mechanical features which control orientation to ensure that the tap-off cannot be mounted incorrectly. The tap-off conductor connection springs are fully shrouded throughout the mounting operation which also provides for the make first, break last of the case ground. Once installed on the busway the patent applied for actuator can then be operated with the supplied actuator key. With the actuator turned ON the interlock is released and can be retracted to allow the switching device to be turned ON. Features Bottom View Mechanically and electrically interlocked with the busway Case ground - make first, break last Vendor neutral 15, 20, 30, 50 and 60A SP/DP/ TP MCBs or MCCBs Fast fit; takes only seconds to install on busway Requires only 1.2 mounting clearance Same Tap Offs fit all Databar ratings from 160A - 800A A wide range of options can be added including LED supply available / phase indication and breaker status monitoring NEMA Twistlock (Front Mount) NEMA Twistlock (Drop Cord) NEMA Twistlock (Bottom Mount ) IEC 309 (Bottom Mount ) 9 10

MCB Tap-offs MCB Tap-offs Single Outlet Tap-offs Triple Outlet Tap-offs Quad Outlet Tap-offs Double Outlet Tap-offs Part Numbering Overview System System Config Device Poles & Manuf. Outlet Type Meter Type 3PA [30] d 1 M DX1 T2 5PA 2E Tap Off Type Tap Off Size Outlet Rating [A] No. of Outlets 11 12

Power and Environmental Monitoring Typical Meter Connection Arrangement The Databar product offers a fully vendor neutral approach to provide the very latest technologies in full power branch circuit metering. Fully integrated systems which include tapoff circuit and end-feed power monitoring or circuit breaker status are available alongside a range of environmental monitoring solutions. Databar power metering allows for multi-tariff sub-billing at Class 1 accuracy. Communication protocols include Modbus RTU, Ethernet and SNMP. Power measurements include: Active and reactive power Active and reactive energy Voltage per phase Current per phase Circuit breaker status is also available via a range of auxiliaries which can then provide open / closed / tripped status. returning to Ethernet gateways in the end feeds or application specific power / energy management outstations / HMI. Power Management from Anord Mardix Anord Mardix holds approvals as a Schneider Electric EcoXpert Critical Power Master for supply and system integration of Power Monitoring Expert, PowerSCADA Expert/ CitectSCADA solutions and also as a Janitza Approved System Integration Partner for GridVis solutions. Typical arrangements include Modbus chains for the tap-offs RJ45 Modbus In / Out Integral Comms Channel with Comms Cover Anord Mardix DCIM Modules Anord Mardix ims - Data Hall Rack Power Management and Billing The ims system has been developed by Anord Mardix to sit above data harvesting applications such as EMS, BMS and other suitable databases. ims provides users with a secure web based portal to manage customer or departmental billing through a wealth of standard or custom reporting tools and innovative graphic interfaces. Modbus Wired Metering In wired metering solutions CAT5e/CAT6 cabling is employed to daisy chain tap-offs back to Ethernet gateways. The aluminium housing has dedicated cabling channels on both the front and back faces and each can carry up to four cables. A comms channel closure strip is provided for cable containment as well. Metered tapoffs are supplied with RJ45 terminals for linking out the Modbus chain. Employed by some of the world s largest data centers in private financial and colocation sectors, this powerful tool provides reporting and management of over 21 million points of data and annual billing of $350 million. 13 14