Installation Instructions Model ZAM-180

Similar documents
Installation Instructions Model FMT

Installation Instructions Model PSC-17C

Installation Instructions Model SNC Serial Network Card for USB Application with Windows

Installation Instructions Model LPB

Installation Instructions Model PSX-12

Installation Instructions Model NIC-C

INSTALLATION INSTRUCTIONS Model VCA2002-A1 Card Cage

INSTALLATION INSTRUCTIONS Model VCC2002-A1 Voice input/output Card

Installation Instructions Models CC-5 / CC-2

Installation Instructions Models FCM-6 / LCM-8 / SCM-8 Model CSB

INSTALLATION INSTRUCTIONS Model VTO2001-U2/U3 Option Module (24 Switches)

Quick Start Installation Guide

VersaMax IP Input Module

Advanced Visual Solutions Ltd

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Connecting a Cisco Input Module

The Model Scalance X204-2 Multimode and X204--2LD Single

INTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module

Installation & Operation Guide

High Power (15W + 15W) Stereo Amplifier

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

16-Way Input 48-Way Output Card

INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

and Network Interface Modules Installation Instructions

Quick Start Installation Guide

RECORD & PLAYBACK KIT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Room Pressurization Controller Pneumatic Output

BS 15 BASIC SERIES USER MANUAL FOR THE SINGLE CHANNEL BELTPACK CONTENTS

Product Data Sheet. Hochiki 8 Way I/O Card. Features

EP/2 Installation Instructions

(Cat. No A1B, -A2B, -A3B, -A3B1, -A4B Series B) Installation Data. Make sure you have these items:

Installation Guide Serial Interface T942SI

Product Data Sheet. BMS/Graphics Interface. Features

EA500. Installation Instructions Transponder

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

N8VEM S-100 BACKPLANE VERSION 04 MAY 3, 2015 J.B.

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

CA-A480-A Elevator Controller. Reference & Installation Manual

TEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.

User s Manual Pulse Encoder Interface Module OTAC-01

Installation Instructions & User Manual

Cerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)

Quick Start Installation Guide

4100/4120-Series Class A / Class B Zone Modules Installation Instructions

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

CAB-BATT, CAB-BATT-R, CAB2-BB, CAB2-BD, CAB3-BB, CAB3-BD, CAB-MP, ID-MP, ID-SP, ID-FP, BCM, OD-LP, OD-BP, OD-GP, REMBOX2, REMBOX4, XLS-MLE6-ADPT,

VersaMax IP I/O Module

V-9939C MICROPHONE ADAPTER

Installation Instructions Model RNI

MAXIMA + Series ROTARY LEVEL CONTROL

PROTECH.

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

GSV-1A4 M12/2 M12/2. Highlights

INSTALLATION INSTRUCTIONS. FST-420 Fiber Station Transceiver

Room Pressurization Controller Electronic Output

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video

TRC-190 User s Manual

Model HM-535 Power Supply Installation and Service Instructions

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

The Shop Interface Unit allows MxPro 4 control panels to send and receive alarm signals from other equipment.

RTU560 Connections and Settings DIN Rail RTU 560CIG10

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Moxa TCC-100 Series User s Guide

MAXIMA+ Series Rotary Level Indicator

HVG400. Installation Guide

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

HARDWARE OPERATIONS MANUAL

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

SoundwebTM. Installation Guide

4.7 Expansion Module MAC00-FS1/FS4

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

Operating instructions. ProcessLine analogue module AC / / 2012

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

INSTALLATION INSTRUCTIONS

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Installing Sentor. Hardware Installation

Installation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...

BIPOLAR OPERATIONAL POWER SUPPLY

PO Box 409 Hanover, MD TEL (410)

4100/4120-Series and 4010ES Relay Modules Installation Instructions

EP-ELVCTL Elevator Control (NION-16C48M)

Installation Instructions

D1V Rotary Control Panel D4S Button Panel PS Power Distribution Module USER MANUAL

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

BACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Cisco ONS CL Shelf Assembly Hardware

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

WA-210. Wall Mounted Amplifier with USB/FM and Bluetooth. Item ref: UK, UK User Manual. Version 1.0

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

INSTALLATION/OPERATION INSTRUCTIONS U3800 MASTER STATION

Installation Instructions

Transcription:

s Installation Instructions Model ZAM-80 Zone Amplifier Module 80W (500-035600 / S24235-B6-A5 (70V)) Installation Instructions for North America INTRODUCTION The Model ZAM-80 from Siemens Industry, Inc. is a CAN data bus module that contains two speaker zones and one audio amplifier, capable of operating at 25 (50W) or 70 (80W) VRMS. The two speaker zones can be wired and operate as either a single Class A zone or a single Class B zone or as two Class B zones independently protected to provide split zone or interleaved speaker zones. The ZAM-80 can also be used as a backup amplifier to serve as a backup for other ZAM-80 amplifiers in a to backup or to many backup. The ZAM-80 mounts at the back of the enclosure of the system and occupies ¼ of the total space of the Mounting Plate. Features ZAM-80 features are as follows: Digital (Class D) audio power amplifier with 80W RMS output power Over all efficiency about 80% under full load Amplifier is supervised for functionality Amplifier is protected against open, short circuit, over current and over modulation Figure ZAM-80 s

Speaker lines are supervised for open, short circuit and ground fault The ZAM-80 is micro controller controlled A FPGA controls the digital audio data stream (ASI Bus) transmitted by the DAC-NET SW update via PMI/PMI-2/PMI-3 (XLS), FCM204-U2 (Desigo Fire Safety Modular), FCM204-U3 (Cerberus PRO Modular) OPERATION The ZAM-80 receives its control and communication data from the DAC-NET and sends its status data to the DAC-NET via the CAN Bus. Therefore it takes sub-address of the DAC-NET. The transmission of compressed or uncompressed audio data from the DAC- NET to the ZAM-80 is realized via ASI (Audio Serial Interface). Transmission on the ASI is executed with a timeslot method and is synchronized with Frame and Bit Synchronize Signals. Via control data on the CAN Bus, the timeslots are allocated to each ZAM-80. Each ZAM- 80 is configured to listen to its corresponding timeslot. Terminal Connections A local audio input is provided to connect an external audio source. The audio input is isolated on the ZAM-80 to prevent ground loops. The local audio input is activated via an external contact. The control of this input will be executed by the amplifier directly. The ZAM-80 will send a message informing the DAC-NET that the ZAM-80 has turned on the local input. It is also possible to activate/ deactivate the local input on the control panel via CAN bus. The speaker lines are individually supervised for open and short circuit. Ground fault is detected in common for both speaker lines on each ZAM-80. CAN TO CC-5 OR PSC-2 / PSX-2 Controls and Indicators The speaker lines are supervised in both the inactive and active state. The speakers must be AC-coupled. The ZAM-80 has one Reset button, seven diagnostic LEDs, level adaptation of the local external audio input and the CAN address switches, one terminal block, two terminal connections and two 60 pin flat ribbon connections as shown in Figure 2. 24V Power Input Figure 2 Terminal Blocks, Controls and Indicators 0V A reset switch is located on the top of the front panel. Pushing the reset switch re-initializes the ZAM-80 operation. 2

The LEDs functions are defined as follows: LED COLOR NORMAL STATE OFF NORMAL STATE ACTION IN OFF NORMAL STATE POWER green ON OFF external voltages fail Check for failure on PSC-2, CC-5, wiring MODULE FAIL yellow OFF ON general trouble at ZAM-80 Failure on ZAM, ZAM-80 needs to be replaced CAN FAIL yellow OFF ON CAN interface trouble Failure on AIC, DAC-NET, CC-5 backplane or other CAN cards/modules ASI FAIL yellow OFF ON ASI interface trouble Failure on ASI OUT and/or ASI IN at this ZAM-80 ZONE ACTIVE green OFF ON Speaker zone active Indicates normal operation on speaker zone ZONE TRBL yellow OFF ON Speaker zone trouble, open circuit or short circuit Check wires to the speakers, EOL resistor(s) and de-coupling capacitors on every speaker ZONE GND FAULT yellow OFF ON unwanted earth ground connection on a speaker line Check wires to the speakers for earth ground connections OVERLOAD yellow OFF ON Refers to Local Audio input only: Press DOWN push button until OVERLOAD LED turns off and NORMAL LED turns on NORMAL green ON OFF Refers to Local Audio input only: No audio signal or audio signal too high/low LOW yellow OFF ON Refers to Local Audio input only: Press UP push button until LOW LED turns off and NORMAL LED turns on Terminal Connections: Power Input: These terminals are used for field wiring as shown in Figure 2-4. This terminal block is non power limited and can supply up to 2A. This Input is connected to the output terminal TB4 of the PSC-2/PSX-2 as shown in Figure. 3

PRE-INSTALLATION The ZAM-80 takes one sub-address on the DAC-NET. To configure the CAN address use the two rotary-switches on the front panel (refer to Figure 2) Remove screws as shown in Figure 3 on the left and the right side of the ZAM-80 housing and remove the front plate. Securing screws for the front plate Securing screws for the front plate Figure 3 Position Of The Securing Screws For setting the speaker line voltage and the low frequency cutoff see Figure 4. Figure 4 Position Of Connectors And Jumpers For Setting The Speakerline Voltage And The Low Frequency Cutoff 4

Setting the Speaker Line Voltage The amplifier supervision has to be configured for the appropriate line voltage, too. Amplifier supervision is configured with jumpers on header X28. Speaker Line Voltage 70V Plug in the coded connector in the position marked 70 V. and set Jumper X28 position 2-3. 70V 25V 00V X28 2 3 Figure 5 Jumper Position 70V Speaker Line Voltage 25V Plug in the coded connector in the position marked 25 V. There is No jumper on X28. 70V 25V 00V X28 2 3 Setting the low frequency cutoff Figure 6 Jumper Position 25V Low frequency cutoff can be set for 240Hz or 0Hz. This setting acts on both local audio input and on all digital channels. Setting for 240 Hz protects small speakers from being overload with bass impulses. Speech intelligibility may be improved. This setting is not recommended for higher quality music reproduction. For 520 Hz low frequency usage, use the 0 Hz setting. 0Hz: Set no jumper on X2 0/240Hz 4 Figure 7 Jumper Position 0 Hz 240Hz: For 240Hz low frequency cut-off two jumpers have to be set. Never set only one jumper. 0/240Hz 4 Figure 8 Jumper Position 240 Hz 5

After having done these pre-installations install the front plate and secure it again. INSTALLATION Remove ELECTRICAL POWER prior to working on equipment. Figure 9 Location Of The ZAM-80 On The Mounting Plate The ZAM-80 can occupy any position on the mounting plate (Refer to Figure 9). When the ZAM-80 is mounted correctly on the Mounting Plate it will be flush on the top, bottom, and right with the Mounting Plate and the mounting screw holes of the PSC-2 will align with the threaded posts. Figure 0 Mounting the ZAM-80 On The Mounting Plate 6

. Install four M5 screws in the threaded posts at the mounting position. Screw each of the M5 screws into the threaded posts 5-6 turns. 2. Place the ZAM-80 over the four screws on the Mounting Plate and slide it down or towards you to rest on the four screws. (Refer to Figure 0.) When the ZAM-80 is in the correct position it will be flush with the top, bottom and right side of the Mounting Plate. 3. Tighten the four screws. WIRING Remove ELECTRICAL POWER prior to working on equipment. All field wiring of the ZAM-80 is connected to the terminal blocks on the upper side of the ZAM-80. The screw terminals can accommodate one 2-8 AWG (Ø 0,5mm-2,5mm²) or two 6-8 AWG, (Ø 0,5mm-,0mm²). To connect external wiring Loosen the screw of the terminal by turning it counterclockwise. Insert the wire into the side of the terminal block. Tighten the screw of the terminal block by turning it clockwise Input Power Wiring NOTES. 4-8 AWG (Ø,0mm -,5mm²) 2. Not power limited. Figure ZAM-80 Input Power Wiring 7

Speaker Line Wiring The configuration of the speaker lines is selectable between Class A, Class B, or 2 x Class B. NOTE: For U.S. installation only, reference to Power Limited is deemed Class 2 and reference to Power Limited 70V speaker circuits is deemed Class 3. Class 2 and Class 3 designations do not apply to Canadian installations. Please refer to the appropriate product installation instructions for further details. Class A: The speaker line is looped back to the system. The end of line resistor (EOL) is connected directly at the ZAM-80 (CC-5/-2). In this configuration the line works during an open circuit condition by feeding it from both sides. In the short circuit condition, the speaker line is not functional. NOTES (Speaker Lines and Backup Amplifier). Use twisted pair or shielded twisted pair. 2. Terminate shields at one end only. 3. Supervised and not power limited. 4. Positive or negative ground faults detected at <0k Ohms for terminals 9-2. Figure 2 ZAM-80 Class A Wiring 8

Class B: A configuration, where the end of line resistor is at the end of the speaker line. The ZAM-80 is capable of single Class B wiring if the unused speaker line is connected to an EOL. NOTES (Speaker Lines and Backup Amplifier). Use twisted pair or shielded twisted pair. 2. Terminate shields at one end only. 3. Supervised and not power limited. 4. Positive or negative ground faults detected at <0k Ohms for terminals 9-0. Figure 3 ZAM-80 Class B Wiring 9

2x Class B: Both lines are used and have the end of line resistor at the end of the speaker line NOTES (Speaker Lines and Backup Amplifier). Use twisted pair or shielded twisted pair. 2. Terminate shields at one end only. 3. Supervised and not power limited. 4. Positive or negative ground faults detected at <0k ohms for terminals 9-2. Figure 4 2x Class B Configuration 0

ELECTRICAL RATINGS Input Power 24V Back Plane Current 0mA 24V Screw Terminal Current @ 80W @ 90W @ 45W @ 0W 9.5A 4.9A 2.7A 0.3A 6.2V Back Plane Current 0mA 24V Standby Current 300mA Maximum Output Power 25 VRMS 50W 70 VRMS 80W Dry Contact Input 24V/0mA power limited

Cyber security disclaimer Siemens products and solutions provide security functions to ensure the secure operation of building comfort, fire safety, security management and physical security systems. The security functions on these products and solutions are important components of a comprehensive security concept. It is, however, necessary to implement and maintain a comprehensive, state-of-the-art security concept that is customized to individual security needs. Such a security concept may result in additional site-specific preventive action to ensure that the building comfort, fire safety, security management or physical security system for your site are operated in a secure manner. These measures may include, but are not limited to, separating networks, physically protecting system components, user awareness programs, defense in depth, etc. For additional information on building technology security and our offerings, contact your Siemens sales or project department. We strongly recommend customers to follow our security advisories, which provide information on the latest security threats, patches and other mitigation measures. http://www.siemens.com/cert/en/cert-security-advisories.htm Siemens AG, I BT DE FS SYS, 2003-200 Siemens Industry, Inc., Building Technologies Division, Florham Park, NJ Siemens Canada Ltd., Oakville, Ontario L6H 0H6 Canada Order No. A24205-A334-B832 (Edition 0) Issued by Siemens AG I BT DE FS SYS D-8379 Munich Delivery subject to availability; right of technical modifications reserved. Document ID A6V0259386