VectorStar ME7838A4 Multiport Broadband/Banded Millimeter-Wave System

Similar documents
VectorStar ME7838A Broadband/Banded Millimeter-Wave System

VectorStar Broadband/Banded Millimeter-Wave Modules

VectorStar ME7828A Series Broadband/Millimeter Wave System

R System Verification Software (SVS)

Direct Connection of OML Frequency Extenders to Keysight s PNA-C (E836xC) VNA for 1-Path 2-Port S-Parameter Measurements

Agilent PNA Series Microwave Network Analyzers

Agilent ENA-L RF Network Analyzers

Keysight N9030A Signal Analyzer Option BBA Analog Baseband IQ Inputs Retrofit Kit

Agilent PNA Series Microwave Network Analyzers

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

Keysight Technologies PNA Series Microwave Network Analyzers

Installation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number

Agilent Upgrade Guide for the 8510 Vector Network Analyzer Product Note

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Keysight Technologies Millimeter Wave Network Analyzers (N5290A/N5291A) Configuration Guide

Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz)

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

PXI Vector Network Analyzer

Software User s Guide

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Lightning 37xxxE Series Vector Network Analyzer

Installation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Agilent RF Network Analyzers PNA Series

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

ATEC (2832) Models 8757A, 85027A/B/C, 85020A/B

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

NV1000 Terminal Equipment Operations Manual Introduction. Manual Part No. MI February, 1996

Model 2657A-LIM-3 LO Interconnect Module

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight Technologies N9020B MXA Signal Analyzer

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number

Agilent ENA RF Network Analyzer

S-Band Redundant LNA Systems

RF Characterization Report

Model GHz 50 Ohm RF Module

Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement

Ku-Band Solid-State Power Amplifier

LevelOne. KVM-0115/KVM / 17-inch LCD KVM Rack Console. User Manual. Version

SERIES MS462XX VECTOR NETWORK MEASUREMENT SYSTEM VERIFICATION KITS OPERATION AND MAINTENANCE MANUAL

Agilent. E5092A Configurable Multiport Test Set. Configuration Guide

5 Performance Verification

Instruction Manual Model Block Translator

LASER PLUS OPERATING INSTRUCTIONS

Precision N Coaxial Calibration Kit

C-Band Solid-State Power Amplifiers

Installing the Cisco 2524 and Cisco 2525 Routers

User Manual VX4234 Digital Multimeter Module

EMSwitch RF Switch Plug-In Card

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution

Modular Block Converter Systems

Agilent. E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

Installation Job Aid for VSP 4850GTS

Agilent Technologies U3020AY03

User Manual LKS-CD17SR 17 LCD Single Rail Console Drawer with Modular KVM Switch

Installation Job Aid for VSP 4450GTX-HT- PWR+

Compact Redundancy Switch 2:1 RSCC-2

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installing the IPS 4345 and IPS 4360

HP 8714B Calibration

MONITORING INTELLIRACK USER MANUAL

RFS Ferrocom Isolators/Circulators

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Infiniium Q- Series Oscilloscopes

Application Note FOR SMA Calibration Kit for VNA. LCAL06A A female calibration kit and used for DC ~ 6.0 GHz VNA test cable with male end connector.

RF switch network. RFB 2000, RFC 2010 or 2020

14.5U 4X SDR/DDR InfiniBand Switch Platform User s Manual. Rev 0.10

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

TRC-190 User s Manual

M250 (M LL) Safety

Agilent 84904, 6, 7K/L Programmable Step Attenuators

System Storage EXP3000 Rack Installation Instructions

M215 (M215-60) Safety

PicoVNA. USB vector network analyzer. Quick Start Guide

Keysight Technologies E5071C Network Analyzer

High Voltage Power Supplies

Replacing the Power Supply

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

120Ra-1 Pentium III Processor Installation Insert

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Advanced Test Equipment Rentals ATEC (2832)

EDGES Receiver Calibration Steps Tom Mozdzen

Application Note. Use of Palm Switches with QuadTech Hipot Testers

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

TABLE OF CONTENTS 1. OVERVIEW... 1

Racal Instruments 1257A. Scalable RF Interface Unit. Product Information. The Racal Instruments 1257A is a Commercial-Off-The

Service Manual. P GHz Active Probe

DANTE BRIDGE. Operation Manual

MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction

Warning - Read the entire VDI User guide for this product prior to operation.

Adapter 2.92 mm-f to 2.92 mm-m

Keysight Combiner and Mechanical Switches Upgrade Kit

Dell MD1280 Storage Enclosure Getting Started Guide

MPI TS150-AIT 150 mm Manual Probe System

Model 2380 Rack-Mount Kit

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Transcription:

Quick Start Guide VectorStar ME7A4 Multiport Broadband/Banded Millimeter-Wave System High Performance Modular Broadband/Banded Millimeter-Wave Vector Network Analyzer (VNA) Multiport Measurement System ME7A4, 70 khz to 0 () GHz Anritsu Company 490 Jarvis Drive Morgan Hill, CA 907-09 USA Part Number: 040-007 Revision: A Published: March 0 Copyright 0 Anritsu Company

. ME7A4 Main Components High Performance Modular Broadband/Banded Millimeter-Wave Vector Network Analyzer (VNA) Measurement System, 70 khz to GHz This guide provides quick setup instructions for the ME7A4 Multiport Broadband/Banded mm-wave VNA System assembly. For additional safety and compliance information, and for more details about the assembly, configuration, setup, and initial testing of the equipment, refer to the VectorStar ME7A4 Series Multiport Broadband Vector Network Analyzers Installation Guide 040-0074. This and all other documentation that supports the ME7A4 is available on the VectorStar User Documentation Disc 090-0007. Calibration, Verification, and System Performance Verification documents are included on a separate disc included with each calibration/verification kit.. ME7A4 Main Components ME7A4 Broadband Systems The ME7A4 Multiport Broadband system consists of the following components: MS447A or MS447B VNA with Option 007 (Receiver Offset) and Option 0x (Modular Broadband Connection Capability) MN497C Multiport Test Set 7B Broadband Test Set 79C Broadband Test Set Four 74A Millimeter-Wave Modules Front and rear panel cables ME7A4 Banded Systems The ME7A4 Multiport Banded system consists of the following components: MS44xA/B VNA with Option 0x MN494C Multiport Test Set 7B Broadband Test Set 79C Broadband Test Set Four 744A-EE, 744A-EW, or four OML/VDI Millimeter-Wave Modules Front and rear panel cables Caution A MS44xA/B VNA unit is heavy. To avoid personal injury, it must be lifted and maneuvered by at least two people during installation. If mounting on a workbench surface, first position the 79C Broadband Test Set with access to its front and rear panels. Stack the remaining test sets on top of one another, then finally the VNA. If mounting into rack or console, make sure the Test Sets have been installed, and that the rack/console is carefully positioned on a flat and level surface. If equipped, make sure any casters are locked. Use two people to lift the VNA unit and two to guide it into its shelf rails. The test loops on the front and rear panels of the VNA are delicate. Be careful not to bump or bend the test loops. QSG- PN: 040-007 Rev. A VectorStar ME7A4 QSG

. Rear Panel Connections Between System Components (MS44xA VNA). Rear Panel Connections Between System Components (MS44xA VNA) In this section, connect the cables between the VNA and the Test Sets as shown in Figure and Table. 7 7 7 7 9 MS44xA VNA 9 4 7 0 MN49xC Test Set 9 7 7 7 7 7B Test Set 4 Ext Alc Out Ext Analog In IF Outputs a b a b External I/O Module Interface Cable Length WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47- Hz -40 VAC 0 VA Max Fuse 0V A T CAUTION 79C Test Set Standard Extended For continued fire protection replace only with specified type and rated fuse. Figure ME7A4 Rear Panel Cable Connections (MS44xA VNA) VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-

. Rear Panel Connections Between System Components (MS44xA VNA) Table. ME7A4 Multiport Rear Panel Cable Connections ( of ) Index Part Number Cable Description Connection From Connection To -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in 4-0- BNC (male-male), 4 in 7 79- a ( cable bundle) -074 a ( cable bundle) DB- DB- 9 00- GPIB, m SMA male-male flexible: -74- -74- -74- -74-4 SMA male-male flexible: -74- -74- -74- -74-4 - a SMA male-male -0 a SMA male-male - a SMA male-male 4-0 a SMA male-male - a SMA male-male -0 a SMA male-male 7 - a SMA male-male MS44xA port Ext Analog Out MS44xA port Ext ALC 7B port (To Test Set) EXT ANALOG OUT 7B port (To Test Set) EXT ALC IN 7B port TO TEST SET EXTERNAL I/O 7B ports (IF INPUTS) a b a b MS44xA ports (Inputs/Outputs) a IF b IF a IF b IF MS44xA port External I/O MS44xA port Dedicated GPIB MS44xA port b loop out MS44xA port b loop in MS44xA port P source loop out MS44xA port P source loop in MS44xA port b loop out MS44xA port b loop in MS44xA port P source loop out 7B port EXT ANALOG IN 7B port EXT ALC OUT 79C port EXT ANALOG IN 79C port EXT ALC OUT 79C port EXTERNAL I/O 79C ports (IF OUTPUTS) a b a b 7B ports (IF OUTPUTS) a IF b IF a IF b IF 7B port TO VNA EXTERNAL I/O MN49xC port IEEE 4. GPIB MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT MN49xC port TO VNA Port Src OUTPUT MN49xC port TO VNA Port Src INPUT MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT MN49xC port TO VNA Port Src OUTPUT QSG-4 PN: 040-007 Rev. A VectorStar ME7A4 QSG

. Rear Panel Connections Between System Components (MS44xA VNA) Table. ME7A4 Multiport Rear Panel Cable Connections ( of ) Index Part Number Cable Description Connection From Connection To -0 a SMA male-male 9 MS44xA VNA 0 MN49xC Test Set 7B Test Set 79C Test Set MS44xA port P source loop in a. Tighten each cable in this group using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). MN49xC port TO VNA Port Src INPUT VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-

. Rear Panel Connections Between Components (MS44xB VNA). Rear Panel Connections Between Components (MS44xB VNA) In this section, connect the cables between the VNA and the Test Sets as shown in Figure or Figure, and Table. Cable Connections (Systems with Option 0 Dual Source Architecture) 7 7 7 7 Ext In ALC and Ext In ALC (With Option 0) 9 MS44xB VNA 9 4 7 0 MN49xC Test Set Ext ALC (With Option 0) 9 7 7 7 7 7B Test Set Ext ALC (With Option 0) 4 Ext Alc Out Ext Analog In IF Outputs a b a b External I/O Module Interface Cable Length Standard Extended WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47- Hz -40 VAC 0 VA Max Fuse 0V A T CAUTION For continued fire protection replace only with specified type and rated fuse. 79C Test Set Figure ME7A4 Multiport BB/mmW VNA System Rear Panel Cables (With Option 0) QSG- PN: 040-007 Rev. A VectorStar ME7A4 QSG

Cable Connections (Systems without Option 0). Rear Panel Connections Between Components (MS44xB VNA) 7 7 7 7 9 MS44xB VNA 9 4 7 0 MN49xC Test Set 9 7 7 7 7 7B Test Set 4 Ext Alc Out Ext Analog In IF Outputs a b a b External I/O Module Interface Cable Length WARNING No operator serviceable parts inside. Refer servicing to qualified personnel. CAUTION Do not operate with power cord ungrounded. ~ LINE INPUT 47- Hz -40 VAC 0 VA Max Fuse 0V A T CAUTION 79C Test Set Standard Extended For continued fire protection replace only with specified type and rated fuse. Figure ME7A4 Multiport BB/mmW VNA System Rear Panel Cables (No Option 0) VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-7

. Rear Panel Connections Between Components (MS44xB VNA) Table. ME7A4 Multiport Rear Panel Cable Connections (MS44xB) ( of ) Index Part Number Cable Description Connection From Connection To -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in -0- BNC (male-male), 4 in 4-0- BNC (male-male), 4 in 7 79- a ( cable bundle) -074 a ( cable bundle) DB- DB- 9 00- GPIB, m SMA male-male flexible: -74- -74- -74- -74-4 SMA male-male flexible: -74- -74- -74- -74-4 - a SMA male-male -0 a SMA male-male - a SMA male-male MS44xB port Ext Analog Out Ext In ALC (No Option 0) (Figure ) Ext In ALC (With Option 0) (Figure ) Ext In ALC (With Option 0) (Figure ) 7B port (To Test Set) EXT ANALOG OUT 7B port (To Test Set) EXT ALC IN (Figure ) (Not used with Option 0) 7B port TO TEST SET EXTERNAL I/O 7B ports (IF INPUTS) a b a b MS44xB ports (Inputs/Outputs) a IF b IF a IF b IF MS44xB port External I/O MS44xB port Dedicated GPIB MS44xB port b loop out MS44xB port b loop in MS44xB port P source loop out 7B port EXT ANALOG IN 7B port EXT ALC OUT 79C port EXT ALC OUT 7B port EXT ALC OUT 79C port EXT ANALOG IN 79C port EXT ALC OUT 79C port EXTERNAL I/O 79C ports (IF OUTPUTS) a b a b 7B ports (IF OUTPUTS) a IF b IF a IF b IF 7B port TO VNA EXTERNAL I/O MN49xC port IEEE 4. GPIB MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT MN49xC port TO VNA Port Src OUTPUT QSG- PN: 040-007 Rev. A VectorStar ME7A4 QSG

. Rear Panel Connections Between Components (MS44xB VNA) Table. ME7A4 Multiport Rear Panel Cable Connections (MS44xB) ( of ) Index Part Number Cable Description Connection From Connection To 4-0 a SMA male-male - a SMA male-male -0 a SMA male-male 7 - a SMA male-male -0 a SMA male-male 9 MS44xB VNA 0 MN49xC Test Set 7B Test Set 79C Test Set MS44xB port P source loop in MS44xB port b loop out MS44xB port b loop in MS44xB port P source loop out MS44xB port P source loop in MN49xC port TO VNA Port Src INPUT MN49xC port TO VNA b OUTPUT MN49xC port TO VNA b INPUT a. Tighten each cable in this group using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). MN49xC port TO VNA Port Src OUTPUT MN49xC port TO VNA Port Src INPUT VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-9

4. Semi-rigid Cable Connections Between System Components 4. Semi-rigid Cable Connections Between System Components Make the cable connections as shown in Figure 4 or Figure, and in Table. If your system has Option 0 Dual Source Architecture (MS44xB only), use Figure 4. If your system does not have Option 0, use Figure. Frequency Calibration Power Measurement Sweep Application Channel Avg System Response 7 Trace Display File Help Scale Marker Preset Standby Operate ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE 4 RF LO Out In In Out 9 Install Termination Removed from VNA RF or RF 0 Figure 4 ME7A4 Multiport Semi-rigid Cable Connections (with Option 0 Dual Source Architecture) QSG-0 PN: 040-007 Rev. A VectorStar ME7A4 QSG

4. Semi-rigid Cable Connections Between System Components Frequency Calibration Power Measurement Sweep Application Channel Avg System Response File 7 Trace Display Scale Help Marker Preset Standby Operate ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE RF LO Out In In Out 9 4 0 Figure ME7A4 Multiport Cable Connections (No Option 0) VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-

4. Semi-rigid Cable Connections Between System Components Table. ME7A4 Multiport Cable Interconnect Part Numbers and Locations ( of ) Index Part Numbers Description/Torque Connection From Connection To -09-4 V (m-m) (MN497C) -77- K (m-m) (MN494C) 77-0 77-4 77- (With Option 0) 77- (No Option 0) 77-9 Front Panel RF Cable (4 each) V or K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel RF Cable K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel LO Cable ( each) K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel RF Cable K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Front Panel LO Cable ( each) K male-male Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). b (In) b (Out) Port Source (In) Port Source (Out) Port Source (In) Port Source (Out) b (In) b (Out) RF (Figure 4) (With Option 0) RF (Figure ) (No Option 0) LO LO RF (Figure 4) (With Option 0) 7B Test Set port RF Out (Figure ) (No Option 0) 7B Test Set port LO Out 7B Test Set port LO Out MN49xC port b (In) MN49xC port b (Out) MN49xC port Port Source (In) MN49xC port Port Source (Out) MN49xC port Port Source (In) MN49xC port Port Source (Out) MN49xC port b (In) MN49xC port b (Out) 7B Test Set port RF In 7B Test Set port RF In 7B Test Set port LO In 7B Test Set port LO In 79C Test Set port RF 79C Test Set port RF 79C Test Set port LO 79C Test Set port LO QSG- PN: 040-007 Rev. A VectorStar ME7A4 QSG

4. Semi-rigid Cable Connections Between System Components Table. ME7A4 Multiport Cable Interconnect Part Numbers and Locations ( of ) Index Part Numbers Description/Torque Connection From Connection To V0 7 MS44xA VNA MS44xB VNA MS447A VNA MS447B VNA MN494C Test Set MN497C Test Set 9 7B Test Set 0 79C Test Set Termination (With Option 0) Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Option 0, 0, or 0, and 0x (Banded) Option 0, 0, or 0, and 0x (Banded) Option 0, 0, or 0, and 0x (Broadband) Option 0, 0, or 0, and 0x (Broadband) (Banded) (Broadband) Remove from VNA port RF or RF (With Option 0) Add to 7B Test Set port RF Out VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-

. Front Panel Cable Connections. Front Panel Cable Connections Make the cable connections as shown in Figure and in Table 4. 9 ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE 0 4 RF LO Out In Port 7 In Out Port 4 Port Port Port Module Port Module Test Port to Module SRC (74A only) Test Port to Module SRC (74A only) Port Module 7 Port 4 Module Test Port to Module SRC (74A only) 4 Test Port 4 to Module SRC (74A only) Figure Front Panel to mm-wave Module Connections QSG-4 PN: 040-007 Rev. A VectorStar ME7A4 QSG

. Front Panel Cable Connections Note The cables for Test Port through Test Port 4 to Module SRC are not used with mm-wave modules 744A-EE, 744A-EW, or 744A-Rx. Table 4. ME7A4 Cable Interconnect Part Numbers and Locations ( of ) Index Part Number Description Connection From Connection To 4 0-09 a,b Coaxial Phase Stable Cable (4 each) V male-female flexible, in Used with 74A Broadband Modules only Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). MN49xC port Port Port Port Port 4 74A port (Port Module) SRC (Port Module) SRC (Port Module) SRC (Port 4 Module) SRC 7 7- a mm-wave Module Interface Cables (for 74A, 744A-EE, 744A-EW modules) Group of cables for each port Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). 79C Test Set: Port, Port RF, LO, Test, Ref, Power/Signal 7B Test Set Port, Port (Port, Port 4) RF, LO, Test, Ref, Power/Signal mm-wave Modules: Port, Port Modules RF, LO, Test, Ref, Power/Signal mm-wave Modules Port, Port 4 Modules RF, LO, Test, Ref, Power/Signal OML Module Interface Cables Group of 4 cables for each port 79C Test Set Port, Port RF, LO, Test, Ref OML Modules Port, Port Modules RF, LO, Test IF, Ref IF 7 7- a Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). VDI Module Interface Cables Group of 4 cables for each port Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). 7B Test Set Port, Port (Port, Port 4) RF, LO, Test, Ref 79C Test Set Port, Port RF, LO, Test, Ref 7B Test Set Port, Port (Port, Port 4) RF, LO, Test, Ref OML Modules Port, Port 4 Modules RF, LO, Test IF, Ref IF VDI Modules Port, Port Modules RF Input, LO Input, Meas. IF, Ref IF VDI Modules Port, Port 4 Modules RF Input, LO Input, Meas. IF, Ref IF 7 7- a mm-wave Module Interface Cables (for 744A-Rx modules) Group of cables for each port Tighten at Test Set using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). 79C Test Set Port, Port LO, Test, Power/Signal 7B Test Set Port, Port (Port, Port 4) LO, Test, Power/Signal Rx Modules Port, Port Modules LO, Test, Power/Signal Rx Modules Port, Port 4 Modules LO, Test, Power/Signal VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-

. Front Panel Cable Connections Table 4. ME7A4 Cable Interconnect Part Numbers and Locations ( of ) Index Part Number Description Connection From Connection To 9 MS44xA VNA - Option 0, 0, or 0, and 0x (Banded) MS44xB VNA - Option 0, 0, or 0, and 0x (Banded) MS447A VNA - Option 0, 0, or 0, and 0x (Broadband) MS447B VNA - Option 0, 0, or 0, and 0x (Broadband) 0 MN494C Test Set (Banded) MN497C Test Set (Broadband) 7B Test Set 79C Test Set a. Do not yet connect the cable ends to the Millimeter-Wave modules. Module connection instructions follow this section. b. Cable 0-09 Coaxial Phase Stable Cable is not included or required when using the 744A-EE, 744A-EW mm-wave modules, or the 744A-Rx Receiver Module. QSG- PN: 040-007 Rev. A VectorStar ME7A4 QSG

. Front Panel to Millimeter-Wave Module Connections. Front Panel to Millimeter-Wave Module Connections Connect the 7B and 79C Broadband Test Set test port cables to the 74A, 744A-EE, 744A-EW, or 744A-Rx Modules as shown below, observing the correct torque limits for each connector. See Figure 7 and Table. Route the cable assemblies through the module cable restraint. Note It is easier to first connect the cables to the module and then mount the module in its bracket. Observe torque instructions where indicated. Each module (except the 744A-Rx) is characterized for a specific VNA Serial Number and VNA Test Port as designated on the module port assignment label. Ensure the module matches the correct VNA and Test Set port. For more detailed information on the modules including DUT Waveguide (WG) connection alignment and custom bracket mounting, refer to 040-00-VectorStar Broadband/Banded Millimeter-Wave Modules Reference Manual. Inverting a Module If necessary, a module can be turned over in the bracket to change the elevation of the W connector. To turn the module over:. Remove the six knurled head thumbscrews from the module.. Turn the module over.. Install the six thumbscrews. TEST 4 REF Power/Signal LO 7 9 RF SRC 74A LO SRC (Not used) RF 74A 0 TEST TEST REF (Not used) Power/Signal Power/Signal REF 744A-EE, 744A-EW LO 744A-Rx (Not used) RF SRC (Not used) Figure 7 Millimeter-Wave Module Connections VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-7

. Front Panel to Millimeter-Wave Module Connections Table. Millimeter-Wave Module Connections Index Cable P/N Description N/A Millimeter-Wave Module in bracket N/A W - mm Connector (74A, 744A-Rx modules) Tighten using a torque end wrench and a plain end wrench mm Torque End Wrench set to 0.4 N m (4 lbf in). Recommended is Anritsu 0-04. mm / 7 mm Open End Wrench. Recommended is Anritsu 0-0. WR-0 or WR- Adapter - mm connector (744A-EE, 744A-EW modules) Use Waveguide Adapter Toolkits (7494-, 7494-, or 7494-4). Tighten using a torque end wrench and a plain end wrench. mm Torque End Wrench set to 0.4 N m (4 lbf in). Recommended is Anritsu 0-04. mm / 7 mm Open End Wrench. Recommended is Anritsu 0-0. TEST - SSMC Connector (74A, 744A-EE, 744A-EW, and 744A-Rx modules) Tighten using a 4 mm (/ in) torque end wrench set to less than 0. N m ( lbf in). Recommended is Anritsu 0- torque wrench. 7- a REF - SSMC Connector (74A, 744A-EE, and 744A-EW modules) 4 Tighten using a 4 mm (/ in) torque end wrench set to less than 0. N m ( lbf in). or Recommended is Anritsu 0- torque wrench. 7- b,c Power/Signal Bi-Lobe Connector (74A, 744A-EE, 744A-EW, 744A-Rx) LO - K Connector (74A, 744A-EE, 744A-EW, and 744A-Rx modules) Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. 7 Module Power and I/O Cable Restraint 0-09 d Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). SRC - V Connector (74A module only) Recommended is Anritsu 0-0. 9 7- a Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). RF - V Connector (74A, 744A-EE, and 744A-EW modules) Recommended is Anritsu 0-0. 0 N/A Factory Calibrated Port Assignment Label N/A Module Serial Number Label a. 74A, 744A-EE, and 744A-EW modules use cable assembly 7-. b. The REF cable is not used in the 7- cable assembly. c. 744A-Rx module uses cable assembly 7-. d. Cable 0-09 Coaxial Phase Stable Cable is used only with the 74A modules. Millimeter-Wave Module Operating Environment The following notes should be observed when operating the 74A and 744A-xx mm-wave Modules: Thermal heat sinking similar to the supplied mounting brackets of the Millimeter-Wave Module should be considered in custom mounting applications. Each 74A Module consumes a maximum of watts. Each 744A-EE and 744A-EW Module consumes a maximum of watts. Each 744A-Rx Module consumes a maximum of 7 watts. The primary heat sink paths for the module is the two side mounting surfaces of the mounting bracket. With the attached cable mounting brackets, the case temperature rise is approximately C to 0 C above ambient. A three () Year warranty is valid for all versions of 744A and 74A modules, with or without mounting brackets attached. QSG- PN: 040-007 Rev. A VectorStar ME7A4 QSG

7. Front Panel to OML/VDI Module Connections 7. Front Panel to OML/VDI Module Connections Connect the front panel cables between the 7B and 79C Test Sets, and the OML or VDI frequency extension modules as shown in Figure, Figure 9, and Figure 0, and as described in Table, Table 7, and Table. Caution To avoid connector damage, observe torque requirements where indicated. ALL PORTS: CAUTION +7 dbm MAX AVOID STATIC DISCHARGE RF LO Out In In Out Port Port 4 7 Port Port Port Module Port Module Port RF, LO, Test, Ref to OML/VDI Module Port RF, LO, Test, Ref to OML/VDI Module Port Module 4 Port 4 Module Port RF, LO, Test, Ref to OML/VDI Module Port 4 RF, LO, Test, Ref to OML/VDI Module Figure Cable Connections between 7B, 79C Test Sets, and OML or VDI Frequency Extension Modules VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-9

7. Front Panel to OML/VDI Module Connections Table. ME7A4 OML/VDI Cable Interconnect Part Numbers and Locations Index Part Number Description Connection From Connection To 4 7- ( each) 7- ( each) MN49xC Test Set 7B Test Set 7 79C Test Set OML Module Interface Cable Assembly Group of 4 cables for each port OML Module Interface Cable Assembly Group of 4 cables for each port VDI Module Interface Cables Assembly Group of 4 cables for each port VDI Module Interface Cables Assembly Group of 4 cables for each port 79C Test Set Port, Port Ref RF LO Test 7B Test Set Port, Port (Port, Port 4) Ref RF LO Test 79C Test Set Port, Port RF Ref Test LO 7B Test Set Port, Port (Port, Port 4) RF Ref Test LO OML Modules: Port, Port Modules Ref IF RF Input LO Input Test IF OML Modules: Port, Port 4 Modules Ref IF RF Input LO Input Test IF VDI Modules: Port, Port Modules RF Input Ref. IF Meas. IF LO Input VDI Modules: Port, Port 4 Modules RF Input Ref. IF Meas. IF LO Input QSG-0 PN: 040-007 Rev. A VectorStar ME7A4 QSG

7. Front Panel to OML/VDI Module Connections From ME7-79C Test Set Port, Port From ME7-7B Test Set Port, Port 4 Ref RF 4 LO Test OML Frequency Extension Modules (Typical) Ref RF LO Test Ref IF RF Input DC Power LO Input Test IF Ref IF RF Input DC Power LO Input Test IF OML Power Supply OML Power Supply Figure 9 VNA/ Test Set Cable Connections to OML Modules Table 7. OML Module Connections Index Cable P/N Description N/A OML Module 4 7- Ref IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. RF Input - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. LO Input - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. Test IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. N/A OML Module Power Supply Connector VectorStar ME7A4 QSG PN: 040-007 Rev. A QSG-

7. Front Panel to OML/VDI Module Connections From ME7-79C Test Set Port, Port From ME7-7B Test Set Port, Port 4 RF Ref Test 4 LO VDI VNA Extender Modules (Typical) RF Ref Test LO RF Input Ref. IF Power Meas. IF LO Input RF Input Ref. IF Power Meas. IF LO Input VDI Power Supply VDI Power Supply Figure 0 VNA/ Test Set Cable Connections to VDI Modules Table. VDI Module Connections Index Cable P/N Description N/A VDI Module 4 a 7- RF Input - K (.9 mm) Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. Ref. IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. Meas. IF - SMA Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. LO Input- K (.9 mm) Connector Tighten using an mm (/ in) torque end wrench set to 0.9 N m ( lbf in). Recommended is Anritsu 0-0. VDI Module Power Supply Connector a.the VDI module connectors may differ slightly than on the illustration shown above. For example, depending on the model and date built, the power supply connector may be round instead of rectangular. QSG- PN: 040-007 Rev. A VectorStar ME7A4 QSG

Anritsu utilizes recycled paper and environmentally conscious inks and toner. Anritsu Company 490 Jarvis Drive Morgan Hill, CA 907-09 USA http://www.anritsu.com