Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

Similar documents
Raven Adapter Harness

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19

InSight Single Implement

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

Cab Box Kit Dome Plug Cab Box Cab Box Lid

DirectCommand Installation DirectCommand Complete Wiring Harness

DirectCommand Installation RoGator Model Year Ag Leader Technology

Direct Injection Module

Ag Leader Technology. DirectCommand Installation RoGator Model Years

DirectCommand Installation RoGator 864/874/1064/1074 (MY 2006 & Earlier) Ag Leader Technology

Ag Leader Technology. DirectCommand Installation Miller Nitro 5000 & 6000 ISO Kit

Ag Leader Technology. DirectCommand Installation Rogator 900/1100/1300 Sprayers

DirectCommand Installation 5 Channel Spreader Control Module Technology

DirectCommand Installation Hardi Spray Box II 39-pin Kit. Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 16

Ag Leader Technology. DirectCommand Installation GVM Cab Kit (MY 2007 and Up) Important Notices

Part Name/Description Part Number Quantity

Note: Indented items indicate parts included in an assembly listed above

Part Name/Description Part Number Quantity

Part Name/Description Part Number Quantity

Note: Indented items indicate parts included in an assembly listed above

Note: Indented items indicate parts included in an assembly listed above

Miller Nitro 4000 Series

DirectCommand Installation Case/Flexi-Coil/New Holland Air Cart Kit (Variable Rate Electro Hydraulic Systems) Ag Leader Technology

Tile Plow Installation O Connell

Tile Plow Installation Gold Digger

Battery Operated Acre Counter User Manual SOFTWARE VERSION 6.0. Loup Electronics

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Megatouch FORCE Monitor Chassis Board Replacement

Rexroth Controller Installation & Operations Manual

General Information. Installation Instructions. 3S-4000 Folding Min-Till Drill Acre Counter Update. Used with: 3S-4000

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Moving-Minds.com Treadmill Desk Operation

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Installation Instructions

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

641G-001A PRINTER KIT INSTRUCTIONS

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

APES-14 HD-6500 & HD-7000 Version Operator s Training Manual

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Upgrade Instructions Printer Terminal Holder

LINEAR ACTUATOR CONTROL Use with NEW LEADER 7 manual

Q2 XBee Handheld Controller Assembly Guide

BRB Systems USA Co. Instruction Manual. USA Trap Solo Voice Release System. 12V & 120V Versions.

E1135C PDU and Pod Upgrade Procedure

Encore XT Manual Gun Upgrade Kit

Service & Maintenance

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

SCdefault. 900 Installation instructions. Accessories Part No. Group Date Instruction Part No. Replaces :36-26 May

Installing the PSU for the S50 and S50N

Cutter Option Installation Instructions

TDM To MiniMech conversion ProceDure

PN Rev A

VM VM

Digital Keypad Introduction

Installing a Power over Ethernet injector

P/S Accessory Cabinet Installation Manual

Please read thoroughly before starting installation and check that kit contents are complete.

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

Replacement Instructions

Basketball Shot Clock Set LX2180 Manual

Control Box Setup - PRSalpha

Parts and Service Manual IMCO

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

INSTRUCTION BULLETIN

Copy Machine Reader. Installation and Setup Guide

E2460GS Oscilloscope Upgrade Kit

RS3000 SERIES BILL ACCEPTORS

Printhead alignment. 1. Turn the printer off. 2. Remove the top cover. See Additional information top cover removal on page 8.

Ion Memory Upgrade. Visit the AMI Entertainment Web site PM

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Field Update Guide. for Raven Viper Pro

HDR TM K HOIST DRUM ROTATION INDICATOR KIT

INSTALLATION INSTRUCTIONS

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Installation Instructions

Operation Manual. 4Bank DMX

INSTALLATION INSTRUCTIONS

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features

UCIT LIVE HD 4 Camera DVR. Installation Manual. 1/18 Version 1.0

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

ACCREDITED SOLUTION. EXPLORER CPN Enclosure

EASTERN LABS. Instructions Model RM /25/2007. Operation. Junction Box Assembly. Different Types of Switch Installations

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

xtablet T1600 Vehicle Holder Installation Guide

M-2300-ZX Focus SVT Brake Conversion Kit INSTRUCTION SHEET

INSTALLATION MANUAL. LO SIDE BOX ADD-ON KIT For driver or passenger side configurations TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK

Seeburg JCU-DEC Kit Convert Your Seeburg DEC Wallbox Into a Jukebox

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

JAN 16 Rev B

Now with Picture Memory

Installation Instructions

ARC-CDJPLAYER INSTALLATION MANUAL Full plug and play kit, universal fit for use in Chrysler vehicles with RA1, RA2, RA3, or RA4 radios.

Security and Convenience Components 519H Three-Channel Receiver

Transcription:

Note: Indented items indicate parts included in an assembly listed above. Part Name / Description Part Number Quantity Direct Command Spra-Coupe 7000 Kit 4100531 1 Liquid Product Control Module 4000394 1 Display Cable 4000727-10 1 Power Cable 3 ft. 4000852-3 1 Power Control Relay 4000379 1 Spra-Coupe Adapter Harness 4000976 1 Implement Cable 3 ft. 4000726-3 1 Spra-Coupe Control Signal Internal 4000946 1 Spra-Coupe Control Signal External 4000945 1 CAN Bus stub 8 in. 4000450-1 1 Module Mounting Plate 40001063 1 Installation Instructions 2005866 1 Dielectric Grease 2002872 2 Cable Install Kit 2000901-1 1 Hardware Kit Large Module 2001354-1 1 Hardware Kit Spra-Coupe 2001360 1. Direct Command Auxiliary Input Module Kit 4100506 1 Auxiliary Input Module 4000437 1 CAN Bus Stub 1 ft. 4000219-1 1 Quick Reference Card 2002831-38 1 Deutsch Dust Plug 12-pin 2002899-12N 1 Deutsch Dust Plug 6-pin 2002899-6 1 PN: 2005866 November 2006-Rev N/C Page 1 of 13

Important Notices You will save time and prevent wrong installation of components by closely following these step-by-step instructions. If you have questions, call Ag Leader Technology at 515-232-5363 x 1. Direction words (LEFT and RIGHT) are commonly used when describing an installation procedure. Interpret direction words as if standing behind equipment looking forward. Signal words (CAUTION, IMPORTANT and NOTE) are provided to draw attention to information that is important for the safe/correct installation and operation of this product. CAUTION will alert you to situations that will impact the physical safety of you or others. IMPORTANT will alert you to the potential for damage to the product or loss of data. NOTE will provide you with additional information to simplify a procedure or clarify a process. Keep parts list and installation instructions for use as a reference after completing installation. Section Contents Item Page Common Components 3 Component and Cable Layout 4 Monitor 5 Display and Power Cables 5 Control Modules 7 Internal Cab Cabling 9 External Cab Cabling 10 Page 2 of 13 November 2006-Rev N/C PN: 2005866

Common Components This section contains illustrations of components common to all installations. Their purpose is to ensure proper identification and installation in the sections that follow. Brown Blue Figure 1. CAN Bus connectors 1. Terminator 2. Plug plugs are not used in all installations. 3. Y-Splice 1. 2. Figure 2. Modules 1. Auxiliary Input Module 2. Liquid Product Control Module PN: 2005866 November 2006-Rev N/C Page 3 of 13

Component and Cable Layout Page 4 of 13 November 2006-Rev N/C PN: 2005866

the Monitor Step-by-step for installing Monitor Parts required for procedure: (1) Display---------------------------- PN: 4000100 NOTE: Monitor can be mounted using the U bracket included in the monitor kit or purchase a RAM mount kit PN: 4100100 at the operators preference. 1. Turn on the Raven console and copy down the boom section widths and flow meter calibration number. 2. Run the machine one last time to make sure all of the components are in working order before removing the console. Verifying that all of the rate control components work will help with any potential trouble shooting issues during the installation. NOTE: The Raven flow meter calibration is in pulses per 10 gallons, the requires pulses per gallon for calibration. To calculate the appropriate values divide the Raven calibration number by 10 before entering into the. NOTE: The Raven boom section widths are in inches; the requires boom widths in feet. Divide the Raven widths by 12 before entering the widths into the. 3. Disconnect the cable from the back of the Raven console. 4. Remove the Raven console from the cab. 5. Mount the Display in a convenient place for operation but out of the operator s line of sight. the Display and Power Cables Step by Step for the Display and Power Cables Parts required for procedure: From Spra-Coupe Kit: (1) Power cable-------------------------------- PN: 4000852-3 (1) Display cable------------------------------- PN: 4000727-10 (1) Power Control Relay--------------------- PN: 4000379 From Auxiliary Input Module Kit: (1) CAN Bus Stub 1 ft.----------------------- PN: 4000219-1 IMPORTANT: Disconnect battery ground. By not disconnecting battery ground you may damage machine or components. 1. Remove outside electrical panel on right side of cab to gain access to terminals. PN: 2005866 November 2006-Rev N/C Page 5 of 13

2. Connect ring terminals of Power Cable PN: 4000852-3 to power connections as shown in picture. Red wire goes to positive connection under red boot and black wire goes to ground stud below it. Positive Negative 3. Feed the gray 4-pin connector thru the hole at the rear of the electrical box and into the cab exiting under the control console. 4. In the cab connect the smaller circular terminal of the Display Cable PN: 4000727-10 to the Monitor rotating the terminal to align it and tighten the collar firmly. 5. Plug the Power Control Relay PN: 4000379 into the 4-pin square Weather Pack connector found on the Display Cable. Press until the latch snaps, locking the two together. 6. Route the Display Cable under the control console and towards the rear of the cab. 7. Plug the Power Cable into the gray 4-pin receptacle of the Display Cable. 8. Plug the one-foot CAN Bus stub PN: 4000219-1 into the round gray connector of the Y splice found half way down the length of the Display Cable. NOTE: To properly connect the Y splice firmly pinch the metal clip against the plastic connection and then mate the ends. Page 6 of 13 November 2006-Rev N/C PN: 2005866

the Control Modules Step by Step for the Control Modules Parts required for procedure: From Spra-Coupe Kit: (1) Liquid Product Control Module ------- PN: 4000394 (1) Module Mounting Plate------------------ PN: 4001063 (1) Hardware Kit-Large Module------------ PN: 2001354-1 From Auxiliary Input Module Kit: (1) Auxiliary Input Module------------------- PN: 4000437 (1) Deutsch Dust Plug 12-pin PN: 2002899-12N 1. Mount the Liquid Product Control Module PN: 4000394 and the Auxiliary Input Module PN: 4000437 to the Module Mounting Plate PN: 4001063 using the hardware from the Large Module Kit PN: 2001354-1 as shown in the picture below. Install Deutsch Dust Plug 12-pin PN: 2002899-12N in maroon receptacle marked SWITCH B. PN: 2005866 November 2006-Rev N/C Page 7 of 13

2. Access the inside of the console by raising the armrest. Remove the top two 5/16 bolts and save them. Install the Module Mounting Plate with modules attached using the same bolts that were just removed. Page 8 of 13 November 2006-Rev N/C PN: 2005866

Internal Cab Cabling Parts required for procedure: From Spra-Coupe Kit: (1) Spra-Coupe Adapter Harness------- PN: 4000976 (1) Implement Cable 3 ft.------------------- PN: 4000726-3 (1) Control Signal Internal Cable-------- PN: 4000964 (1) CAN Bus stub 8 in.---------------------- PN: 4000450-1 (1) Dielectric Grease------------------------ PN: 2002872 IMPORTANT: Use the Dielectric grease to coat the seals and terminals of each connector as you plug them in. Step by Step for Internal Cab Cabling 1. Route the Spra-Coupe Control Signal Internal Cable PN: 4000964 from the inside of the cab thru the same hole below the console that the Power Cable passed thru. Gray circular connector goes outside. 2. Plug the gray 4-pin connector of the CAN Bus Stub from the Display Cable into the 4-pin receptacle marked CAN BUS of the Auxiliary Input Module. 3. Connect the Implement Cable PN: 4000726-3 to the Display Cable at the large circular connector, rotate the connectors to align them and tighten the nut firmly. 4. Plug round end of CAN Bus Stub 8 in. to gray terminal of Y Splice on Implement Cable then plug gray 4-pin connector into gray 4-pin receptacle marked CAN BUS of Liquid Product Control Module. 5. Plug gray 2-pin connector of Implement Cable into gray 2-pin receptacle on red and black power lead from Liquid Product Control Module. 6. From the Control Signal Internal Cable, plug the gray 6-pin connector into the gray 6-pin receptacle of the Auxiliary Input Module marked RADAR. 7. Plug the black 12-pin connector into the black 12-pin receptacle marked AUXILIARY of the Liquid Product Control Module. Weather Pack connector with red jumper wire or optional Implement Switch must be in place for system to function. 8. Plug gray 8-pin connector into gray 8-pin receptacle marked CHANNEL ONE of Liquid Product Control Module. 9. Under control console, disconnect the left hand or inside circular cable from the bottom of the console. PN: 2005866 November 2006-Rev N/C Page 9 of 13

10. Connect the Spra-Coupe Adapter Cable PN: 4000976 to the bottom of the console then connect the original Spra-Coupe cable to the Spra-Coupe Adapter Cable, aligning ends and tighten connections firmly. 11. Plug the green 12-pin connector into the green12-pin receptacle marked SWITCH A of the Auxiliary Input Module. 12. Plug the gray 12-pin connector into the gray 12-pin receptacle marked BOOM of the Liquid Product Control Module. External Cabling Parts required for procedure: From Spra-Coupe Kit: (1) Control Signal External Cable ------ PN: 4000495 (1) Spra-Coupe Hardware Kit------------- PN: 2001360 Page 10 of 13 November 2006-Rev N/C PN: 2005866

Step by Step for External Cabling 1. On right rear corner of cab remove filter cover by turning black knob counter-clockwise. 2. Knock out large center plug and four smaller plugs. 3. Place the gray round receptacle end of the Control Signal Internal Cable installed earlier thru the large hole and secure it to the bulkhead with the four #4-38 screws and nuts provided in Hardware Kit Spra-Coupe PN: 2001360. 4. On left side of sprayer drop the dry hopper to make access easier. Route the circular gray cable end of the Control Signal External Cable PN: 4000495 towards right rear corner of cab. Pull cable up thru bottom of filter cavity and connect it to gray bulkhead receptacle installed in step 2. 5. Back on left side of sprayer find Raven product control module as shown in picture. Remove black 12-pin plug from bottom receptacle of module. Connect the unplugged sprayer cable to the black 12-pin receptacle end of the Control Signal External Cable. Use the Deutsch Dust Plug Narrow12-pin included with the cable to seal the sprayer module from dirt and moisture. PN: 2005866 November 2006-Rev N/C Page 11 of 13

Black 12-pin connector 6. Locate the gray 4-pin connector on the sprayer and connect both the plug and receptacle ends of cable in series as shown in picture below. Gray 4-pin connector Page 12 of 13 November 2006-Rev N/C PN: 2005866

7. Tie cables up out of the way of operator and secure them outside where they will not be damaged or caught in pinch points as sprayer is operated. 8. Replace any covers removed during installation. 9. Reconnect battery ground. Setting Up the Monitor 1. Refer to the Quick Reference guide for setting up the monitor. Installation Notes PN: 2005866 November 2006-Rev N/C Page 13 of 13