Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Similar documents
Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Universal Expander Module in Low Profile Enclosure. P/N: INSTALLATION MANUAL

Fibre Modem - Single-mode

Installation Manual. Contents

Revision 1.4 October Integriti. Security Controller (ISC) SECURITY, ACCESS CONTROL & AUTOMATION SYSTEM INSTALLATION MANUAL

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

Revision 3.1 March IP Door Controller. P/No: IPD INSTALLATION MANUAL OVERVIEW

Intelligent 4 Door Access Module P/No: / INSTALLATION MANUAL

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

2-Way Wireless I/O Expander Installation Guide

Model 3OOO ACCESS 4000

Quick Start Installation Guide

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

High Level Lift Protocol Controller Model TS0868

Two Door Controller GEN-045

PRT-RDS2 Standard 2 Reader Expander

IPassan Installation guide

Installing Sentor. Hardware Installation

Simple & Easy Installation

PRT-PX16 16 PGM Output Expander

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010

CA-A480-A Elevator Controller. Reference & Installation Manual

Colour Graphic Terminal User Manual. Rev 3.1

Model HM-535 Power Supply Installation and Service Instructions

6222 Two Door Module Technical Operations Manual

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Sigma XT Ancillary Board (K588)

CONCEPT 3000/Access 4000 User Manual UK Supplement

CA111x-series Arming Station

EA500. Installation Instructions Transponder

C5S120 Installation and Connection Guide

Installation & User Manual

TruPortal Output Expansion Board Quick Reference

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Connecting a Cisco Input Module

Installation & User Manual V2.08

Product Data Sheet. BMS/Graphics Interface. Features

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

PRT-PSU-DIN-2A. Protege DIN Rail 2A Intelligent Power Supply. Installation Manual

EnCell Battery Cell Monitor

Connecting a Cisco Output Module

UC-2000 Installation Manual Unicorn Computers Technology Limited

Installation Guide Serial Interface T942SI

Installation Instructions

PRT-RDE2 Ethernet 2 Reader Expander

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

ATS125x 4-Door DGP Installation Manual

Features. Description. Physical

Connecting a Cisco Reader Module

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

D/E Remote Relay Panel User Guide

genesis genesis I/O Expander - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured I/O Expander GEN-020

Integriti User Manual. Elite / EliteX LCD Terminal Keypads

PR602LCD v1.0 Installer Manual Rev. A

Installation guide for PR302 v2.0 Rev. E

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Wireless Key fob, Key pad & Receiver Range

DIN-RAIL EXPANDER int-iors_en 10/14

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

Measurement Systems Datascan Installation and User Guide

Electrical Demand Specification (Reference SOP: )

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

JVA Z Series Keypad Bus Wiring Installation Manual

Installation Manual for D244X Series 24-volt Power Supplies

Cardax FT Controller 3000

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Installation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...

PRO3200 Professional Modular Access Control Hardware

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

SOFTWARE VERSION 3.10

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

ACTpro Single Door IP Controller. Operating & Installation Instructions

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Innovative Circuit Technology Ltd.

G3 Series DeviceNet TM Technical Manual

PRODUCT DESCRIPTION PACKAGE CONTENTS

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

Expansion Module HZS 541-1S

KT-300 DOOR CONTROLLER INSTALLATION MANUAL DN KANTECH SYSTEMS INC.

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

TruPortal Dual Door Interface Module Quick Reference

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Sigma-XT-ECU-LCS Extinguishant Control Unit Local Control Station Operation and Maintenance Manual

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DMX36 USER MANUAL Features Revision 1 Suits PCB revision June, 2014

NS1 Connection Unit Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Remote units Hands free or telephone handset options available. Master to remote and remote to master calling

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Transcription:

Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs, 2 Auxiliary outputs and 2 Siren drivers. The Module is supplied as a PCB and Installation Kit for installation in a suitable Integriti enclosure. The number of Zones or Auxiliaries can be further expanded using UniBus expander boards. See page 8 for details of the expansion options. The 8Zone Expander is one type of Wired Zone Expander Module in the Integriti hardware platform. Up to 99 Wired Zone Expander Modules can be installed on an Integriti Controller. The number of 8Zone Expander Module Zone Inputs that can be utilized in a single system will depend on the licensing options. IMPORTANT NOTES: 1) This Revision 2 Installation Manual is for Revision B PCBs only. For Revision A PCBs please refer to Revision 1 of this manual available from the Inner Range Support Web page. The PCB Part Number and Revision is printed at the top centre and bottom right of the PCB. e.g. 936005_B. See PCB layout item 16 on page 3. 2) Integriti 8Zone Expander firmware in Revision B PCBs must be V1.30 or later. The firmware is installed in the factory, but if the firmware is changed in the field, do NOT use any version prior to V1.30. Downgrading the firmware to an earlier version may cause damage to Siren speakers. 3) The Integriti 8 Zone LAN Expander Module is identified on the Integriti Controller LAN as a Wired Expander Module (E). 4) Integriti Software and Controller Compatability. Latest Integriti Software and Controller Firmware is recommended. Firmware prior to V2.5.2 is not advised. Parts List Integriti 8 Zone Expander Module PCB. Installation Manual. (This document) Installation Kit containing: 6 x Metal M3 PCB Mounting Clips. 1 x Cable; Chassis Earth to PCB. 6 x M3x10mm screws. 1 x 6.3mm QC connector (Spare) 3 x 8 Way plugon screw terminals. 2 x 4 Way plugon screw terminals. 1 x 6 Way plugon screw terminals. 1 x 2 Way plugon screw terminals. 10 x 2k2 Endofline resistors. (redredblackbrownbrown). For 8 Zone Inputs plus 2 x spare. 10 x 6k8 Endofline resistors. (bluegreyblackbrownbrown) For 8 Zone Inputs plus 2 x spare.

2 Integriti 8 Zone LAN Expander Module. Installation Manual. Installing the Module Installation environment should be maintained at a temperature of 0º to 50º Celsius and 15% to 85% Relative humidity (noncondensing) 1 The Module can be mounted in a suitable metal enclosure using the PCB standoffs provided, or other suitable PCB standoffs. The enclosure should be installed in a suitable and convenient location according to the instructions supplied with the enclosure. 2. If installed in an Inner Range metal enclosure, the Normally Closed Tamper Switch is inserted into the hole provided in the Tamper switch bracket. The Tamper Switch bracket must then be positioned in either of the two slots provided in the chassis before the chassis is mounted on the wall. The Tamper switch is wired between the TAMP and 0V terminals on T1. (Switch is Open circuit when plunger depressed) 3. The Module Number is set using DIPswitches 1 to 7. See table below. Assembled Tamper switch in the Tamper bracket LINKS. No Link Options are currently available on this Module. Module Numbering SW1. DIPswitches 1 to 7: Set the Expander Module number. See table below. SW1. DIPswitch 8: Not currently used. Must be set to OFF. The Module number equals n + 1, where n is the binary number set on the DIPswitches. Module No: DIPswitch: 1 2 3 4 5 6 7 8 Binary value: 1 2 4 8 16 32 64 n/a 1 off off off off off off off Always Off. 2 ON off off off off off off 3 off ON off off off off off 4 ON ON off off off off off 5 off off ON off off off off 6 ON off ON off off off off 7 off ON ON off off off off 8 ON ON ON off off off off 9 off off off ON off off off 10 ON off off ON off off off 11 off ON off ON off off off 12 ON ON off ON off off off 13 off off ON ON off off off 14 ON off ON ON off off off 15 off ON ON ON off off off 16 ON ON ON ON off off off through to 64 ON ON ON ON ON ON off...99 off ON off off off ON ON

Revision 2.1 July. 2014 3 INTEGRITI 8ZONE LAN EXPANDER PCB 1 2 3 4 16 5 6 7 8 9 10 11 12 13 14 15 16 1. P2 External Power Supply connection. Connect to P2 on an appropriate Integriti Power Supply using the cable provided with the Power Supply. 2. P7 / L25 / L26 Ethernet Connector & status LEDs. Not Fitted. 3/4 LK1 / Port 0. Not Fitted (Factory Only). 5. DIPswitch SW1. Module number. See page 2. 6. L24. 3.3V Microprocessor supply is present. 7. L1 / L2 / L3 L1 LAN Data Receive / Fault indication. L2 LAN Data Transmit / Fault indication. L3 Fault. See details and table on page 7. 8. T1. Tamper Switch Connection. Connections for Normally Open Tamper Switch. No EndofLine resistors required. See Installing the Module on Page 2. 9. T7. Siren Connections. See page 5. S1INT: To internal 8 Ohm Siren speaker. S2EXT: To external 8 Ohm Siren speaker. 10. P3 / L14. UniBus. Connector & Status LED for local UniBus boards. e.g. UniBus 8 Zone Expander or 8 Auxiliary Expander. See pages 7 and 8. 11. T9. Earth Terminal. Connect to chassis using earth wire supplied in the installation kit. 12 T11 / T12. Zone Input connections. See Page 4. 13. T18. Detector Power. Power Supply output for +12V Detector Power. See pages 4 and 5. 14. T5 / L9 / L10. Auxiliary outputs. T5 Aux1 and Aux 2 Relay output connections. (See page 5) L9 / L10 Auxiliary On indication. 15. T8 / P6. RS485 LAN Connections. See page 6. POS: Connect LAN +ve to power the Module or to power subsequent modules if required. NEG: Connect LAN Common 0V (VE). A: LAN Data A connection. B: LAN Data B connection. Note: P6 provides a temporary LCD Terminal connection via the LAN Ancillary Cable (P/N: 993028) for commisioning, fault finding, etc. 16. PCB Part Number and Revision. See Important Note 1 on Page 1. 936005_A = Rev. A. 936005_B = Rev. B.

4 Integriti 8 Zone LAN Expander Module. Installation Manual. ZONE INPUT WIRING The Endofline Resistors must be installed on the detection device. Typical Detection devices with Normally Closed Alarm contacts and Normally Closed OR Normally Open Tamper Contacts are wired as follows: Schematic diagram Norm. Closed Tamper Contact 2k2 e.g. For 2k2/6k8 EOL scheme. 2k2 = Sealed 9k (2k2 + 6k8) = Unsealed (Alarm) Open or Short Circuit = Tamper Z1 Z2 Z3 Norm. Open Tamper Contact 6k8 Norm. Closed Alarm Contact Detection devices with Normally Open Alarm contacts are wired in exactly the same manner as shown. When programming the Zone Input, however, the option to Swap Alarm and Seal must be enabled. (Set to [Y]es) Example. PIR Movement Detector NC COM + TAMPER DET DET + 6k8 2k2 4core Security Cable ZONE INPUT Note that the connector terminals may be arranged and labelled differently to the example shown above. Please check the manufacturers documentation. The table opposite provides details of some of the more common Detector terminal labelling. Example. Reed Switch Label NC in example COM Alternative labels N/ C ALARM NC RELAY NC Descriptio n Normally contacts + + 12V DC Power Supply Input TAMPER TAMPER NC 24 HR Closed Alarm output Normally Closed Tamper Contacts 6k8 2k2 Figure8 or Security Cable ZONE INPUT

S2EXT S1INT DET+ DET AX2 AX1 Revision 2.1 July. 2014 5 AUXILIARY WIRING Auxiliary Relay Outputs AX1 and AX2 can switch up to 2A at 30Volts DC. It is NOT recomended to switch AC loads. A separate external power supply must be used for the auxiliary devices if the combined current draw by the Auxiliary devices + LAN current + Detectors + Other peripheral expansion boards exceeds the current available from the normal Power Supply source. e.g. The connected Integriti Smart Power Supply or the LAN. See Power Supply specifications for details. If an Inductive load (eg door lock) is connected then a Clamp diode should be fitted across the load. Cathode (bar) to +ve. (see diagram below) T5 NC COM NO Clamp Diode MUST be fitted across Lock. Cathode to +ve. Lock + External Power Supply. (Batterybacked) NC COM NO 12V Strobe + 1.2k Lock or Solenoid control. An External Power Supply is used to power inductive loads to protect the Controller, provide longer battery backup & minimise the possibility of earth loops. T2 12V Strobe or LED control. The Common (COM) and Normally Open (NO) contacts are used. One is connected to DET. The load is then connected between DET+ and the other contact taking note of the polarity. SIREN WIRING A maximum of two 8 Ohm Siren speakers may be connected to each siren output, wired in parallel. Normally Closed Siren cover Tamper switches may be wired in series with the speaker cable. This method utilizes the siren speaker circuit monitoring. T7 > 0V > 0V Cable: 14/0.2 Minimum When wiring 2 speakers in parallel, the Siren Cover Tamper Switches should be connected to Zone Inputs and programmed for Tamper processing. Siren cover tamper switch. (Normally Closed) Siren cover tamper switches Normally Closed NOTE: If highimpedance devices such as Piezo Siren speakers are used, a 6k8 Resistor should be fitted across the Piezo Siren device terminals to Seal the Siren Tamper System Input.

6 Integriti 8 Zone LAN Expander Module. Installation Manual. LAN Wiring MODULE POWERED FROM INTEGRITI EXTERNAL POWER SUPPLY (Recommended) The LAN is connected using twisted pair cable. e.g. RS485 / RS422 data cable or Category 5 cable. One pair is used for Data A & B, and the other pair is used for POS & NEG. If the Module has a local Power Supply connected, the LAN+ terminal may be used to provide power to LCD Terminals, etc. in the vicinity of the Expander module. However, if used in this way, note that this terminal must not be connected to the POS terminal on other Expanders, Control module, Power Supplies or any other Module where LAN+ is a power source. If required, the LAN to subsequent Modules may derive +12V from the incoming LAN cable. * See diagram. Current drawn from LAN POS and DET+ must not exceed the limit of the Power Supply source. LAN+ 0V A B TAMP From Previous LAN module A B + * + A B To next LAN module MODULE POWERED FROM THE LAN NOTES: 1. * If both LAN + wires provide a Power supply source, the one that is not required to power the Module must not be connected. 2. If UniBus boards are to be connected to this Module, an external Power Supply must be used. 3. Ensure that adequate power supply current and backup battery capacity are available from the power supply source when powering the Module from LAN+. See Note 1. * LAN+ 0V A B TAMP 0V + A B + A B From Previous LAN module To next LAN module

Revision 2.1 July. 2014 7 Status and Fault LEDs L1 L1 (RX) Valid LAN packet received or LAN Fault indication. See table below. L2 L2 (TX) LAN packet sent or LAN Fault indication. See table below. L3 FAULT. ON = LAN Fault. Refer to LAN Problems table below for fault details. L9 L10 ON = Auxiliary 1 On ON = Auxiliary 2 On L14 UniBus Flashing Idle. No UniBus cards connected. OFF OK. UniBus Card/s communicating correctly. ON Fault. Problem with one or more UniBus Cards. e.g. Address conflict. L24 3V3 3.3V Microprocessor supply OK. LAN Problems L1 L2 EXPLANATION / REMEDY ON OFF NO ROOM. Too many Modules on the Network. Check limits and licencing. Flash ON EXISTS. Duplicate Module. Module number already in use by a module of the same type. Flash Flash DIM. Dimensions. Module number selected is too big. Select a lower Module number that is not already in use or check limits and licencing. OFF ON UNKNOWN. Module type unknown. Controller firmware upgrade required. ON ON NO ADDRESS. Module is unaddressed. (Not communicating with the Controller) ON Flash Module disabled.

8 Integriti 8 Zone LAN Expander Module. Installation Manual. Expansion Options P3 is the Integriti UniBus Port. UniBus is a connection bus for local expansion boards which are typically installed in the same enclosure using the cable supplied with the board. The UniBus port on an 8 Zone Expander Module can be used to provide additional Zones and Auxiliary outputs. The following UniBus options are compatible with this Module: Inner Range Part Number. Description. 996500 UniBus 8 Zone Expander board. 996510 UniBus 4 Relay Expander board. 996515 UniBus 8 Relay Expander board. 996540 UniBus 16Floor Lift Interface board. Up to 6 UniBus boards in total may be connected to a host Module. The limit on the number of any particular type of UniBus board that can be connected is determined by the total number of entities supported by the Module and the UniBus board. e.g. Integriti Wired Expander Modules such as the 8 Zone Expander, support up to 32 Zones in total. Therefore up to 3 UniBus 8Zone Exander boards may be connected. When a new UniBus board is added to a Module, the Unsecured System Input will be triggered to indicate that a new UniBus board is present. IMPORTANT NOTES: 1. A suitable Integriti Smart Power Supply must be connected to the Module when UniBus boards are used. Integriti 2A Smart Power Supply. P/N: 996090PCB&K Integriti 3A Smart Power Supply. P/N: 996091PCB&K Integriti 8A Smart Power Supply. P/N: 996092 2. Ensure that adequate power supply current is available for any UniBus boards connected to the 8Zone LAN Expander Module. Specifications Mechanical PCB dimensions: L: 200mm. W: 94mm H: Allow 45mm. Installation environment: 0º to 50ºC. 1585% relative humidity (noncondensing) Electrical Power Supply Input: 11V to 14V DC Current Consumption. 70mA idle (with 2k2 EOL on all 8 Zones) 110mA with both Auxilairy relays On. (i.e. 20mA per Relay) NOTE. These figures do NOT include the current required by: Any peripherals such as UniBus boards, Lamps or Warning devices, etc. being powered from the UniBus Port, DET+ or LAN+ Siren speakers. Relay Contact rating: Overcurrent Protection. 2 Amps @ 30VDC. Provided via selfresetting electronic fuses on the Integriti Power Supply connected to the P2 External Power connector. If activated, removing the additional load or short circuit from the relevant output will restore the output to normal operation. Disclaimer: 1. The manufacturer &/or it s agents take no responsibility for any damage, financial loss or injury caused to any equipment, property or persons resulting from the correct or incorrect use of the system or it s peripherals. The purchaser assumes all responsibility in the use of the system and it s peripherals. 2. While every effort has been made to ensure the accuracy of this manual, the manufacturer assumes no responsibility or liability for any errors or omissions. Due to ongoing development, this manual is subject to change without notice. 2013 2014. Inner Range Pty. Ltd. Document Part No: 636005