1 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual

2 The specifications and descriptions of products and services contained in this document were correct at the time of printing. Integrated Control Technology Limited reserves the right to change specifications or withdraw products without notice. No part of this document may be reproduced, photocopied, or transmitted in any form or by any means (electronic or mechanical), for any purpose, without the express written permission of Integrated Control Technology Limited. Designed and manufactured by Integrated Control Technology Limited. Protege and the Protege Logo are registered trademarks of Integrated Control Technology Limited. All other brand or product names are trademarks or registered trademarks of their respective holders. Copyright Integrated Control Technology Limited All rights reserved. Publication Date: January PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

3 Contents 1 Welcome Document Conventions Mounting Removal Cabinet Tamper Switch AC Power Supply 7 4 Backup Battery 8 5 Encrypted Module Network 9 6 Output Load Connection Output Current Influence on Output Load Operation Core Temperature on Output Load Operation Inputs (Zones) Trouble Inputs Outputs Online Mode PGM Outputs Offline Mode AC Fail Status Output Battery Fail Status Output Intelligent Monitoring Monitoring Setup Address Configuration LED Indicators Status Indicator Fault Indicator Power Indicator V1 Output/V2 Output Indicators Battery Indicator Temp Indicator Over Current Indicator PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

4 12 Error Code Indication Error Code Display Mechanical Diagram Mechanical Layout Technical Specifications Ordering Information Warranty Contact 28 4 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

5 1 Welcome Thank you for purchasing the Protege DIN Rail 2A Intelligent Power Supply by Integrated Control Technology. The Protege System is an advanced technology security system designed to provide integration with building automation, apartment complex control and HVAC in one flexible package. Communication is over a proprietary high speed protocol across an encrypted local area network and AES Encrypted Proprietary RS-485 module network. Using modular-based hardware design, system installers have the flexibility to accommodate any installation whether it's small, large, residential or commercial. The Intelligent Power Supply provides 12VDC power suited to powering security, access control or automation devices along with large numbers of Protege network powered modules. The Intelligent Power Supply allows for simple and powerful monitoring of supply currents and voltages. Flexible module network architecture allows large numbers of modules to be connected to the RS-485 module network. Up to 250 modules can be connected to the Protege system in any combination to the network, over a distance of up to 900M (3000ft). Further span can be achieved with the use of a network repeater module. Locking a network prevents the removal, substitution or addition of modules to the module network effectively preventing any tampering with the system. The current features of the Intelligent Power Supply include: Industry standard DIN Rail mounting Online and remote upgradeable firmware Secure encrypted RS-485 module communications When receiving the Intelligent Power Supply you should find the kit contains the items listed below. Please note that if you do not have the correct contents, you should contact your distributor immediately. Protege DIN Rail 2A Intelligent Power Supply Protege DIN Rail 2A Intelligent Power Supply Installation Manual DIN Rail mounting strip Ohm EOL termination resistor Red/Black backup battery wires For more information on the Protege DIN Rail 2A Intelligent Power Supply and other Integrated Control Technology products please visit our website ( 1.1 Document Conventions i Indicates a warning or cautionary message Indicates an important note or advisory information Indicates a hint or suggestion [TEXT] Bold text enclosed in brackets is used to show a section number or address of a programmable option or information on programming shortcut sequences PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

6 2 Mounting The Intelligent Power Supply is designed to mount on standard DIN Rail either in dedicated DIN cabinets or generic DIN Rail mounting strip. A section of this DIN Rail strip has been provided as a mounting option. When installing the Intelligent Power Supply ensure that there is adequate clearance around all sides of the device and that air flow to the vents of the unit is not restricted. It is recommended to install the Intelligent Power Supply in a location that will facilitate easy access for wiring. It is also recommended that the Intelligent Power Supply is installed in electrical rooms, communication equipment rooms, closets or in an accessible area of the ceiling. 1. Hook the lower tabs under the bottom edge of the DIN Rail. 2. Push the Intelligent Power Supply against the DIN Rail mount until the upper tab clips over the upper rail. 2.1 Removal The Intelligent Power Supply can be removed from the DIN Rail mount using the following steps: 1. Insert a flat blade screwdriver into the hole in the tab at the top of the Intelligent Power Supply. 2. Lever the tab up and rotate the unit off the DIN Rail mount. 2.2 Cabinet Tamper Switch The enclosure tamper input signals to the monitoring station or remote computer that the Intelligent Power Supply enclosure has been opened. The tamper input switch should be mounted into the steel bracket provided and connected to the tamper connection terminal and the V- terminal as shown below. The tamper input opens and closes trouble input AExxx:01 on the Intelligent Power Supply. Tamper Switch Bracket V2+ V- V1+ V- 12VDC OUTPUT 2 12VDC OUTPUT 1 TP TAMPER C NO C NC BATT OK AC OK FORM B CONTACTS (50mA max) Tamper Input Connection 6 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

7 3 AC Power Supply The Intelligent Power Supply shall be supplied by a dedicated electrical power source rated for a minimum 10Amp load and have a dedicated circuit breaker. Do not use a switch controlled breaker or a switched electrical point to supply electrical power. Connect the primary of a 16 to 16.5 VAC, 50-60Hz, 40VA or greater transformer to the electrical circuit and run the secondary to the AC Input on the Intelligent Power Supply terminals. Transformer B+ B- B+ B- AC AC Mains Input AC Power Connection Specific regional regulations may allow the transformer to be mounted inside the cabinet enclosure. In this case wire the electrical circuit to the electrical termination point inside the cabinet enclosure and the secondary wires of the transformer to the AC Input on the Intelligent Power Supply. The earth wire shall be routed to the terminal on the Intelligent Power Supply when using an internal transformer. Warning: This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Codes (NEC US) or the Canadian Electrical Codes (CEC Canada). Termination of wiring to the Intelligent Power Supply while power is applied or the battery is connected may cause serious damage to the Intelligent Power Supply and will VOID ALL WARRANTIES OR GUARANTEES. Power the unit only after all wiring, configuration and jumper settings are completed. Extra care must be taken when wiring the AC inputs. Improper connection will cause permanent damage to the Intelligent Power Supply. PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

8 4 Backup Battery It is recommended that a minimum of a 7Ah battery is used as the main backup battery. From the accessory bag provided, connect the RED and BLACK battery termination wires to the B+ and B- plugs. Connect the spade terminals to the battery as shown below. Connection of the battery in reverse will not damage the Power Supply but will cause the battery fuse (6A resettable fuse) to open, requiring resetting by removal of all connections to the B+ and B- plugs for approximately 30 seconds. An additional pluggable connector allowing for the use of an alternative or any additional backup battery(s) is located next to the standard backup battery connector. The connections of this extra connector are in parallel with the standard connector. B+ B- B- B+ AC AC - + Gel Cell Backup Ba ery Battery Connection Warning: Only attach standard lead acid batteries. Do not connect the battery wires or B+ and B- plugs of the Power Supply to any other ancillary device (siren, lock or mag clamp etc). An incorrect connection may cause erroneous faults or serious damage to the Power Supply and will VOID ALL WARRANTIES OR GUARANTEES. The battery test procedure uses a special algorithm to prevent deep discharge and increase battery endurance. A dynamic battery test is performed every ten minutes when mains power is present and a battery condition alarm will be generated if the battery is either disconnected or shows poor capacity. Battery fault conditions will activate the battery trouble zone associated with the address assigned to the Power Supply. In addition to the dynamic battery test procedure, the Power Supply performs a battery presence test every 60 seconds, which determines whether the presence of a backup battery is detected. Similarly, a battery condition alarm will be generated and the battery trouble zone associated with the address assigned to the Power Supply will also be activated. 8 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

9 5 Encrypted Module Network The Intelligent Power Supply incorporates encrypted RS-485 communications technology. Network power is supplied by the N+ and N- terminals. N+ N- NA NB Network communications input from the Protege Integrated System Controller or previous Protege module Standard Communications Connection Connection of the communications and network power should be performed according to the diagram shown. It is important that the N+ network communications power be 12VDC supplied from an independent battery backed power supply unit or a networked module capable of supplying the required voltage to all devices on the RS-485 network. Always connect the Intelligent Power Supply NA and NB terminals to the NA and NB terminals of the communication network. + AUX - Z1 COM Z2 Z3 COM Z4 AUX power from module or external power supply Protege Controller or module supplying power to networked devices N+ N- NA NB N+ N- NA NB N+ N- NA NB Next module on network Network Power Supplied by Network Module Warning: The 12V N+ and N- communication input must be supplied from only ONE point. Connections from more than one 12V supply may cause failure or damage to the Intelligent Power Supply or device supplying network power. The 330 Ohm EOL (End of Line) resistor provided in the accessory bag MUST be inserted between the NA and NB terminals of the FIRST and LAST modules on the RS-485 network. These are the modules physically located at the ends of the RS-485 network cabling. PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

10 First Module on RS-485 Network Last Module on RS-485 Network N+ N- NA NB N+ N- NA NB 330R 330R To Next Module From Previous Module End of Line Resistors 10 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

11 + - 6 Output Load Connection The Intelligent Power Supply provides two sets of 12VDC output terminals, V1+ and V2+. Both V1+ and V2+ outputs are individually fused. i A maximum current output of 1.0 Amps at 12VDC can be provided across each output at any one time. However, if a single current output of 2.0 Amps is required, then both outputs need to be connected together in parallel. When any inductive load including electric locking devices is powered by the Intelligent Power Supply, a reverse EMF protection diode must be placed across the positive (V1+ or V2+) and negative (V-) terminals at the device. 12VDC Electric Locking Device IN4007 Diode V2+ V- V1+ V- 12VDC OUTPUT 2 12VDC OUTPUT 1 Example Output Load Connection i The 1N4007 diode shown MUST be installed across the + and terminals of any inductive load such as electric locks, magnetic or motorized devices. 6.1 Output Current Influence on Output Load Operation In addition to the comprehensive front panel diagnostic indicators, the following table illustrates how the total output current drawn from the Power Supply will influence the operation of the V1 and V2 Outputs. Output Load Current Output Load Operation Status 0 ~ 2.0A 2.0 ~ 2.5A 2.5A ~ Short Circuit Outputs Enabled (Mains Power) Outputs Supplied by Battery Output Over-Current Failure Trouble Input Activated Over-Current Output Shutdown Activated PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

12 6.2 Core Temperature on Output Load Operation In addition to the comprehensive front panel diagnostic indicators, the following table illustrates how the core temperature of the PSU will influence the operation of the V1 and V2 Outputs. Core Temperature Output Load Operation Status < 70 C 70 C ~ 85 C > 85 C Outputs Enabled (Mains Power) Outputs Supplied by Battery Output Over-Current Failure Trouble Input Activated Over-Current Output Shutdown Activated 12 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

13 7 Inputs (Zones) The Intelligent Power Supply has no physical input (zone) connections. The Intelligent Power Supply monitors 8 trouble inputs used to report trouble conditions. A trouble input is in most cases not physically connected with an input in to the Intelligent Power Supply; rather it is related to a status condition within the system. For example a module communication fault causes a trouble input to open as a result of the communication failure. 7.1 Trouble Inputs Each Intelligent Power Supply can monitor up to 8 trouble inputs. Trouble inputs are used to monitor the status of the Intelligent Power Supply and in most cases are not physically connected to an external input. The following table details the trouble inputs that are configured in the system and the trouble type and group that they activate. Input Number Description Type Group AExxx:01 Module Tamper System Tamper System AExxx:02 Mains Failure Power Fault General AExxx:03 Low Battery/Battery Failure Power Fault General AExxx:04 Output Voltage Low Power Fault General AExxx:05 Output Over-Current Failure Power Fault General AExxx:06 Core Temperature Over-Temp Failure Power Fault General AExxx:07 Reserved None None AExxx:08 Module Offline Module Offline System Replace 'xxx' with the appropriate address of the Intelligent Power Supply that you are programming. i The Intelligent Power Supply emulates an Analog Expander module on the Protege module network. This means that all programming, trouble input and PGM output information is stored in and reported by the Analog Expander records when programming via the Protege Alphanumeric LCD Keypad or Protege software. PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

14 8 Outputs The Intelligent Power Supply has 2 outputs that can operate as either programmable outputs (PGMs) or as predefined status outputs, depending on the network status of the module on the Protege system. 8.1 Online Mode Upon successfully completing the initial registration with any Protege System Controller, the outputs of the Intelligent Power Supply operate in Online Mode. The module will then continue to operate in online mode until a firmware update is carried out. While in online mode, the 2 outputs function as programmable outputs (PGMs) and can be used to activate bell sirens, lighting circuits, door locks, relay accessory products and other automation points. PGM Outputs The 2 PGM Outputs each have a Solid State relay. The connection example below shows the control of an external LED indicator. LED 1K5 OHM V2+ V- V1+ V- 12VDC OUTPUT 2 12VDC OUTPUT 1 TP TAMPER C NO C NC BATT OK AC OK FORM B CONTACTS (50mA max) PGM Connection i Switching inductive loads that can produce high back EMF voltages or large voltage induced spikes can cause the Intelligent Power Supply to behave unexpectedly and should be avoided. A suitable isolation circuit must be installed between the relay contacts of the Intelligent Power Supply and the inductive load. The outputs used for both PGMs are rated for low power use only (50mA, 12V Max). Incorrect use may cause erroneous faults or serious damage to the Intelligent Power Supply and will VOID ALL WARRANTIES OR GUARANTEES. 14 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

15 8.2 Offline Mode Until connection to any Protege System Controller is established, the outputs of the Intelligent Power Supply operate in Offline Mode. While in offline mode, the 2 outputs function as status outputs. In addition to the comprehensive front panel diagnostic indicators, these status outputs offer additional information that can aid the installer in diagnosing faults and conditions. AC Fail Status Output The AC Fail Status Output has a Solid State relay. The output relay contacts disconnect (Normally Open) when AC power is removed and the unit remains running on backup battery power. Upon restoring AC power, the output relay will revert back to its default state (Normally Closed). Ensure common ground between devices V+ V- Z1 Z2 Z3 C Z4 C TP C NO C NC BATT OK AC OK TAMPER FORM B CONTACTS (50mA max) PRT-ZX16-DIN PRT-PSU-DIN-2A AC Fail Connection This output is suited for connection to an input on a Protege module with spare inputs available so that the Power Supply AC status can be externally monitored. The connection example above shows monitoring of the AC Status set up in conjunction with a Protege DIN Rail 16 Zone Input Expander. PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

16 Battery Fail Status Output The Battery Fail Status Output has a Solid State relay. The output relay contacts connect (Normally Closed) when either the backup battery has been disconnected, or when the Power Supply is running on backup battery power without AC power and the backup battery voltage drops below 11.2V. Upon reconnecting a backup battery with a voltage greater than 12.5V, the output relay will revert back to its default state (Normally Open). Ensure common ground between devices V+ V- Z1 Z2 Z3 C Z4 C TP C NO C NC BATT OK AC OK TAMPER FORM B CONTACTS (50mA max) PRT-ZX16-DIN PRT-PSU-DIN-2A Battery Fail Connection This output is suited for connection to an input on the Protege System for early detection of complete power failure. The connection example above shows monitoring of the Battery Status set up in conjunction with a Protege DIN Rail 16 Zone Input Expander. The outputs used for both the AC Fail and Battery Fail Status Outputs are rated for low power use only (50mA, 12V Max). Incorrect use may cause erroneous faults or serious damage to the Power Supply and will VOID ALL WARRANTIES OR GUARANTEES. 16 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

17 9 Intelligent Monitoring The Intelligent Power Supply is able to relay information about critical system voltages, currents and temperature to the Protege Integrated System Controller by registering as an Analog Expander module on the Protege network. The Protege Integrated System Controller can then store these values in system registers that can be viewed live from the Protege System Management Suite. 9.1 Monitoring Setup The Intelligent Power Supply will register with the Protege Integrated System Controller as an Analog Expander module, AExxx. The channels for each Intelligent Power Supply will monitor: Channel 1: Voltage at V1+ output Channel 2: Voltage at V2+ output Channel 3: Battery voltage Channel 4: Total current i The Log Channel Data option may also be selected to view the raw data as it is received in the event log. However, this will create a large amount of events and should only be used for verifying the reception of data. For information on configuring analog outputs for use in the Protege System, please refer to Application Note AN017: Configuring Variables and Analog Inputs available at PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

18 10 Address Configuration The address of the Intelligent Power Supply is configured via programming and will require entry of the module serial number. The serial number can be found on the identification sticker as shown in the example below. Protege DIN Rail Intelligent Power Supply PRT-PSU-DIN-2A HW Version Boot Version App Version Language English AB34CD Serial Number Please refer to the Protege GX DIN Rail Integrated System Controller Installation Manual for address programming details. 18 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

19 11 LED Indicators The Intelligent Power Supply includes comprehensive front panel diagnostic indicators that can aid the installer in diagnosing faults and conditions. In some cases an indicator may have multiple meanings depending on the status indicator display at the time Status Indicator The Status indicator displays module status of the Intelligent Power Supply. State Continuous fast flash (green) Continuous slow flash (green) Description Module attempting registration with controller Module successfully registered with controller i Single flash (red) Module communications activity When the fault and status indicators are flashing alternately, the module is in the identification mode, enabling the installer to easily identify the module in question. Upon either a module update or the identification time period set expiring, the module will return to normal operation Fault Indicator The Fault indicator is lit any time the module is operating in a non-standard mode. State i Continuous slow flash (red) Constantly on (red) Description Module is in boot mode awaiting firmware update Module is in error state and will flash an error code with the status indicator. Refer to the Error Code Display section to determine the error. When the fault indicator is on, the status indicator will show an error code. Refer to the Error Code Display section for more information. PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

20 11.3 Power Indicator The Power indicator is lit whenever the correct module input voltage is applied across the AC input terminals. State Description Constantly on Correct module input voltage applied Constantly off Incorrect module input voltage applied 11.4 V1 Output/V2 Output Indicators The V1 Output and V2 Output indicators will show the status of the 12VDC output. State Description Constantly on 12VDC output operating OK Constantly off 12VDC output failure 11.5 Battery Indicator The Battery indicator will show the status of the backup battery. State Description Continuous flash (red) Backup battery is disconnected Constantly on (red) Backup battery failed its dynamic battery test Constantly on (green) Last backup battery dynamic test successful 11.6 Temp Indicator The Temp indicator will show the status of the unit's core temperature. State Description Constantly on (red) Core temperature exceeded. Over Temp Shutdown Activated Continuous flash Core temperature within 15 C of Over Temp Shutdown Constantly on (green) Core temperature OK 20 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

21 11.7 Over Current Indicator The Over Current indicator will show the status of the output current for both V1+ and V2+. State Description Constantly on Output current exceeded. Over Current Shutdown Activated Constantly off Maximum output current not exceeded PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

22 12 Error Code Indication When the Intelligent Power Supply attempts to register or communicate with the system controller a registration error can be generated indicating that it was not successful Error Code Display The following table is only valid if the FAULT indicator is CONSTANTLY ON and the STATUS indicator is FLASHING RED. If the fault indicator is FLASHING the Intelligent Power Supply requires a firmware update or is currently in firmware update mode. The status indicator will FLASH RED with the error code number. The error code number is shown with a 250ms ON and OFF period (duty cycle) with a delay of 1.5 seconds between each display cycle. Flash Error Description Unknown Error Code The error code returned by the system controller could not be understood by the Intelligent Power Supply. Contact Integrated Control Technology. Firmware Version The firmware version on the Intelligent Power Supply is not compatible with the system controller. To clear this error, update the module using the module update application. Address Too High The Intelligent Power Supply address is above the maximum number available on the system controller. To clear this error change the address to one within the range set on the system controller, restart the Intelligent Power Supply by disconnecting the power. Address In Use The Address is already in use by another Intelligent Power Supply. To clear this error set the address to one that is not currently occupied. Use the view network status command to list the attached devices, or the network update command to refresh the registered device list. Controller Secured Registration Not Allowed Controller is not accepting any module registrations. To allow module registrations use the network secure command to change the secure setting to not secured. Serial Number Fault The serial number in the device is not valid. Return the unit to the distributor for replacement. Locked Device The Intelligent Power Supply or system controller is a locked device and cannot communicate on the network. Return the unit to the distributor for replacement. 22 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

23 13 Mechanical Diagram The mechanical diagram shown below outlines the essential details needed to help ensure the correct installation of the Intelligent Power Supply. V1 / V2 Outputs Tamper Input Battery Fail Output / PGM 2 AC Fail Output / PGM 1 Status Indicators Over Current Indicator 12VDC Input RS-485 Input Battery / AC Input Connections PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

24 14 Mechanical Layout The mechanical layout shown below outlines the essential details needed to help ensure the correct installation of the Intelligent Power Supply. 78.4mm 90mm PRT-PSU-DIN-2A FRONT 44.1mm 36.4mm PRT-PSU-DIN-2A BACK 90mm 66.6mm 78.4mm 24 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

25 15 Technical Specifications i The following specifications are important and vital to the correct operation of the Intelligent Power Supply. Failure to adhere to the specifications will result in any warranty or guarantee that was provided becoming null and void. Integrated Control Technology continually strives to increase the performance of its products. As a result these specifications may change without notice. We recommend consulting the ICT website ( for the latest documentation and product information. Power Supply AC Input Voltage 16 to 16.5VAC 60Hz Operating AC Input Current 16.5VAC, 16VAC when Total Combined Current = 2.5A 16.5VAC, 16VAC when Total Combined Current = 1.7A Operating Current 140mA (Typical) Total Combined Current 1.7A (Max) using a 37/40VA transformer 2.5A (Max) using a 60VA or greater transformer Electronically limited at 2.5A DC Output (Auxiliary) 11.0V-12.3V, 1.0A (Typical) Electronic Shutdown at 1.85A Battery Charging Battery Low Battery Restore Electronic Disconnection Communication RS-485 Inputs Tamper Trouble Inputs 8 Outputs PGM Outputs Dimensions 350mA (Typical) 11.2VDC 12.5VDC 9.4VDC Isolated Module Network Dedicated Hardware Tamper Input 2 Solid State Relay Outputs, 50mA 12V Max Dimensions (L x W x H) 78.4 x 90 x 60mm (3.08 x 3.54 x 2.36") Weight Temperature Operating Storage Humidity i 183g (6.46oz) 0-49 C ( F) C ( F) 0%-93% non condensing, indoor use only (relative humidity) It is important that the unit is installed in a dry cool location that is not affected by humidity. Do not locate the unit in air conditioning or a boiler room that can exceed the temperature or humidity specifications. PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

26 16 Ordering Information Please use the following product codes when placing an order for the Protege DIN Rail 2A Intelligent Power Supply. PRT-PSU-DIN-2A Manuals and additional literature are available on the ICT Website ( under the Support section. 26 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

27 17 Warranty Integrated Control Technology (ICT) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. ICT does not install or connect the products and because the products may be used in conjunction with products not manufactured by ICT, ICT cannot guarantee the performance of the security system. ICT's obligation and liability under this warranty is expressly limited to repairing or replacing, at ICT's option, any product not meeting the specifications. In no event shall ICT be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits, stolen goods, or claims by any other party caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January

28 18 Contact Integrated Control Technology welcomes all feedback. Please visit our website ( or use the contact information below. Integrated Control Technology P.O. Box North Harbour Post Centre Auckland New Zealand 11 Canaveral Drive Albany North Shore City 0632 Auckland New Zealand Phone: Fax: Web: or 28 PRT-PSU-DIN-2A Protege DIN Rail 2A Intelligent Power Supply Installation Manual January 2013

29

30

PRT-PX16 16 PGM Output Expander

PRT-PX16 16 PGM Output Expander PRT-PX16 16 PGM Output Expander Installation Manual CONTENTS Protégé System Introduction... PGM Expander... Features... PGM Expander Specifications... Protégé System Management Suite... Protégé Modules...

More information

PRT-RDS2 Standard 2 Reader Expander

PRT-RDS2 Standard 2 Reader Expander PRT-RDS2 Standard 2 Reader Expander Installation Manual CONTENTS Protégé System... Introduction... Reader Expander... Features... Reader Expander Specifications... Protégé System Management Suite... Protégé

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

PRT-RDE2 Ethernet 2 Reader Expander

PRT-RDE2 Ethernet 2 Reader Expander PRT-RDE2 Ethernet 2 Reader Expander Installation Manual PUBLICATION INFORMATION This manual covers firmware versions 1.44 or higher of the Protégé 2 Reader Ethernet Expander when operating on hardware

More information

Proximity Card and Pin Reader Installation Manual

Proximity Card and Pin Reader Installation Manual Multi Prox Proximity Card and Pin Reader Installation Manual PUBLICATION INFORMATION 60A9 - Draft Release Version 0.1.2 71D0 - Version 1.0.5 CONTENTS Introduction... 1 Legend... 2 Terminology... 2 Mounting...

More information

2-Way Wireless I/O Expander Installation Guide

2-Way Wireless I/O Expander Installation Guide 2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...

More information

Protégé Eclipse LED Keypad Installation Manual PRT-KLES

Protégé Eclipse LED Keypad Installation Manual PRT-KLES Protégé Eclipse LED Keypad Installation Manual PRT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated Control Technology

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications 12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception

More information

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,

More information

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

Introduction. 1. RF Module

Introduction. 1. RF Module Introduction RISCO Groupʹs 2 Way Wireless I/O & X10 Module is an extension module enabling wired devices to be connected to the Agility Wireless system. The Wireless I/O Module supports 4 hardwired zones,

More information

PWRguard PLUS Spring City Drive Waukesha, WI

PWRguard PLUS Spring City Drive Waukesha, WI PWRguard PLUS www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2016, All rights reserved. All trademarks are the property of their respective

More information

Wireless Expansion Module V2.0 OMN-RCV3. Reference & Installation Manual. Stand-Alone System

Wireless Expansion Module V2.0 OMN-RCV3. Reference & Installation Manual. Stand-Alone System Wireless Expansion Module V2.0 OMN-RCV3 Reference & Installation Manual Stand-Alone System Table of Contents Introduction...3 What s New with Version 2.0... 3 Technical Specifications... 3 System Features...

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. Pro Series DC Power Supply INSTRUCTION MANUAL 855-343-001 Models: ICT690-12S/ICT690-12SB ICT690-24S/ICT690-24SB ICT690-48S/ICT690-48SB ICT1190-12S/ICT1190-12SB ICT1190-24S/ICT1190-24SB

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

X-18s Users Manual. X-18s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

X-18s Users Manual. X-18s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc. X-18s User Manual Revisions Revision Description 1.0 Page 2 Initial release Introduction Section 1: Introduction The X-18s expansion module is used with the X-600M controller. The X-18s has ten, high-current

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

Broadband Automatic Disconnect Switch. User Manual

Broadband Automatic Disconnect Switch. User Manual Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved. R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.

More information

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc. X-12s User Manual Revisions Revision Description 1.0 Page 2 Initial release Introduction Section 1: Introduction The X-12s 8-Relay expansion module is used with the X-600M controller. The X-12s has eight

More information

SOFTWARE VERSION 3.10

SOFTWARE VERSION 3.10 738PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

INTELLIGENT DOCKING STATION USERS MANUAL

INTELLIGENT DOCKING STATION USERS MANUAL Kodiak Mobile by Jotto Desk 209 W. Easy St., Rogers, AR USA 72756 Customer Service: 877.455.6886 http://www.kodiakmobile.com PART NUMBER: 450-4011 - Last Update: 06.2009 INTELLIGENT DOCKING STATION USERS

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

MCX402DR-BRD I/O expander. Operating Manual

MCX402DR-BRD I/O expander. Operating Manual Roger Access Control System MCX402DR-BRD I/O expander Operating Manual Product version: 1.0 Firmware version: 1.0.2.255 Document version: Rev. B Design and application The MCX402DR-BRD is I/O expander

More information

LCI Load Cell Junction Box with Fault Monitor

LCI Load Cell Junction Box with Fault Monitor LCI Load Cell Junction Box with Fault Monitor User Manual www.mantracourt.co.uk The LCI Load Cell Failure Alarm Manual Chapter 1 Introduction to the LCI...2 Chapter 2 Installing the LCI...3 Figure 2.1

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1 AXS-100 I/O Expander 1. INTRODUCTION The is an input / output expander for the AXS-100 access control panel. It contains eight analog inputs and eight dry contact relays output. Up to four boards may be

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

THOR Battery Backed DC Power Supply Reference Manual

THOR Battery Backed DC Power Supply Reference Manual THOR Battery Backed DC Power Supply Reference Manual Revision A Firmware Compatibility: V1.03 P/N 60098001 Revised: 4/26/2012 INDUSTRIAL CONTROL LINKS, INC. 12840 Earhart Avenue Auburn, CA 95602 Tel: (800)

More information

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION

Power Hub Cat. No. 83A00-1. Installation Manual WEB VERSION Power Hub Cat. No. 83A00-1 Installation Manual WARNINGS AND CAUTIONS Read and understand all instructions. Follow all warnings and instructions marked on the product. Do not use this product near water

More information

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B OPERATIONS MANUAL n.form I/O Expander (RACK MOUNT) Document Number: 200-0009 Rev B table of contents INTRODUCTION FEATURES & CAPABILITIES 1 WIRING General I/O Configuring The System Using The System 4

More information

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions BlueGuard FE Bluetooth Enabled Access Control MODEL BG-FE Operating Instructions CAUTION AND SAFETY INFORMATION IMPORTANT: If the equipment is used in a manner not specified in this manual, the protection

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D244X Series 24-volt Power Supplies Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

MR51e Reader Interface

MR51e Reader Interface J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA

More information

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1 BrewTroller Phoenix Owners Manual Updated - March 14, 2016 BREWTROLLER PHOENIX 1 2016 BrewTroller All Rights Reserved. Product warranty or service will not be extended if: (1) the product is repaired,

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

One Channel and Two Channel DALI Relay Device

One Channel and Two Channel DALI Relay Device Installation Guide DGOZ-RLY-10A-01 DGOZ-RLY-10A-02 One Channel and Two Channel DALI Relay Device REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU

More information

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs EIDX_M Series A Line of Managed Ethernet Switching Hubs INTRODUCTION INSTALLATION GUIDE The EIDX_M Series of managed Industrial Ethernet switches provides the user with a sophisticated instrument with

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. DC UPS Series 2 INSTRUCTION MANUAL 855-146-200 Models: ICT24012-15IBD ICT24012-15IBDM ICT24012-30IBDM WARNING Risk of serious personal injury or damage to equipment and

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

X-11s Users Manual. X-11s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

X-11s Users Manual. X-11s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc. X-11s User Manual Revisions Revision Description 1.0 Page 2 Initial release Introduction Section 1: Introduction The X-11s 2-relay expansion module is used in conjunction with the X-600M controller. The

More information

Expandable Power Systems

Expandable Power Systems Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision: INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console ACC1-25 (Part # 63971-002) ECM Motors Revision: 10.01.13 Page: 2 of 11 Table of Contents Safety Precautions...3 Overview...3 Specifications...4

More information

ACLD Channel Opto-isolated Digital Input Board

ACLD Channel Opto-isolated Digital Input Board ACLD-9182 16 Channel Opto-isolated Digital Input Board @ Copyright 1996 All Rights Reserved. Manual edition 01, January 1996 The information in this document is subject to change without prior notice in

More information

Cardkey S300 Enclosures

Cardkey S300 Enclosures Cardkey S300 Enclosures Product Bulletin Code No. LIT-12011184 Issued March 13, 2007 Supersedes April 10, 2006 Introduction Johnson Controls S300 enclosures provide a secure tamper-resistant housing for

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other

More information

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA PD10 Pulse Divider Instructions PROUDLY MADE IN THE USA ISO 001:200 Certified Company General Information General Information...Page 3 Features...Page 3 Specifications...Page 4 Installation Mounting...Page

More information

Rapier Series Switch Quick Install Guide

Rapier Series Switch Quick Install Guide Rapier Series Switch Quick Install Guide Rapier 24i Rapier 48i Rapier 16fi Rapier Series Switch Quick Install Guide Document Number. Copyright 1999-2006 Allied Telesis Inc. 19800 North Creek Parkway, Suite

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

ZC Series Zone Monitoring Controllers

ZC Series Zone Monitoring Controllers ZC Series Zone Monitoring Controllers Installation Instructions MANUAL Reset Controllers Model Description Part Number ZC-1 1 Zone Controller 0421 ZC-2 2 Zone Controller 0422 ZC-3 3 Zone Controller 0423

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INSTALLATION GUIDE

A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INSTALLATION GUIDE EISwitch A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INTRODUCTION INSTALLATION GUIDE The EIS series Ethernet Interconnect Switch in the CTRLink family provides a solution for those industrial

More information

Please take serious note of the following warnings:

Please take serious note of the following warnings: TPDIN-SC48-20 MPPT Solar Controller with Passive PoE Switch Wireless Base Stations and Client Devices Surveillance Cameras Remote Control Remote Lighting Off Grid Electronics Congratulations! on your purchase

More information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY CUSTOMER SERVICE If you have any questions or require additional information please contact Customer Service at 877-455-6886, Monday though Friday, 8:00am - 5:00pm CST. TECHNICAL SUPPORT Kodiak Mobile

More information

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01 ROSSLARE MODE 1 2 DOOR 3 4 5 6 7 8 9 0 # AC-115 Hardware Installation and User s Guide 10/01 ROSSLARE Hardware Installation and User s Guide for the AC-115 Access Control System MODE 1 2 DOOR 3 4 5 6 7

More information

High Speed Remote I/O Module

High Speed Remote I/O Module High Speed Remote I/O Module EXF-RC15 The Unitronics EXF-RC15 is a High Speed Remote I/O Module that offers three High Speed Counter inputs and four high speed outputs. Overall, the EXF-RC15 offers 9 digital

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Telephone Line Monitor USER GUIDE

Telephone Line Monitor USER GUIDE Telephone Line Monitor USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC OPERATION Our Telephone

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc

Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc Quick Start Guide ELPRO 105UL Wireless I/O Receiver Unit man_105ulr_quickstart_v18.doc ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide About this document This document is the ELPRO 105UL Wireless

More information

DCM Digital Control Modules

DCM Digital Control Modules DCM Digital Control Modules TECHNICAL MANUAL Version 1.2 November 2011 Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions before using the equipment.

More information

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK INTRODUCTION NSI DIGITAL DIMMING SYSTEM INSTALLATION AND OPERATION GUIDE The NSI DDS 5300 and DDS 5600 dimmers represent a key part of a state of the art, integrated lighting control system. These dimmers

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 3YEAR WARRANTY & LIMITATION OF LIABILITY TRI-TRONICS COMPANY, INC. warrants that the products delivered by it will be of the kind and quality described in the order or contract

More information

Installation & Operation

Installation & Operation LED Readout Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon

More information

Installation Instructions

Installation Instructions Lucci Remote Fan Control Non Dimming SKU# 210019 Rated Voltage 240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions

More information

Installation Instructions Model PSC-17C

Installation Instructions Model PSC-17C Installation Instructions Model PSC-17C 17 Amp Power Supply INTRODUCTION The Model PSC-17C from Siemens Industry, Inc. is a high current power supply that provides the Fire Alarm system (Sprachalarmsystem

More information

TB-100 ControLynx Terminal Block

TB-100 ControLynx Terminal Block TB-100 ControLynx Terminal Block TECHNICAL MANUAL Version 1.3 September 2006 Copyright This technical manual and the equipment, firmware and software described herein are copyrighted by INTENT DIGITAL

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

MTGW. Installation Guide. CAN-RS-485 BUS Gateway

MTGW. Installation Guide. CAN-RS-485 BUS Gateway MTGW EN Installation Guide CAN- BUS Gateway MTGW Installation Instructions 1.0 Overview Trademarks Microsoft Windows 98/2000/XP are registered trademarks of Microsoft Corporation in the United States and

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

EP-ELVCTL Elevator Control (NION-16C48M)

EP-ELVCTL Elevator Control (NION-16C48M) EP-ELVCTL Elevator Control (NION-16C48M) Product Installation Document This document covers the procedures and specifications for installing the above listed unit and when appropriate, information regarding

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1. WPP-531-X-ADA-STROBE(LP3P)-SPK1.07UNVLr3-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1.07UNVLr3 FIRMWARE Serving the Telephone

More information

Quick Start Guide. ELPRO 905U-L Wireless I/O Receiver Unit. man_905u-l-r_quickstart_v1.9.doc

Quick Start Guide. ELPRO 905U-L Wireless I/O Receiver Unit. man_905u-l-r_quickstart_v1.9.doc Quick Start Guide ELPRO 905UL Wireless I/O Receiver Unit man_905ulr_quickstart_v1.9.doc ELPRO 905UL Wireless I/O Receiver Unit Quick Start Guide About this document This document is the ELPRO 905UL Wireless

More information

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849

More information

Tomorrow s Technology Today.

Tomorrow s Technology Today. Tomorrow s Technology Today. ICTProtegeWX: The future is here. Introducing ProtegeWX At ICT we re committed to delivering industry-leading technology straight to the people who need it most. We already

More information