ABB MEASUREMENT & ANALYTICS DATA SHEET. JDF200 Field Indicator

Similar documents
General Specifications

General Specifications

TEPI11 P/I signal converter

C160 Wall-/Pipe Mounted Universal Process Indicator

Dräger Polytron 8200 Stationary gas detector (CatEx)

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

Series 3730 Type Electropneumatic Positioner

Digital Indicator DS 48/24 E

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

FICHA TÉCNICA DE PRODUTO

Resistance thermometer With spring-loaded tip Model TR55

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Threaded thermocouple Miniature design Model TC10-D

Threaded resistance thermometer Miniature design Model TR10-D

Indicomp 4 Bargraph Indicator

Supplementary Components WirelessHART products

FICHA TÉCNICA DE PRODUTO

WirelessHART Adapter SWA70

LST300 Compact ultrasonic level transmitter

Flow Measurement SITRANS F M

LineMaster 100 Continuous-line Recorder

Flow Measurement SITRANS F M

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Technical Information Promonitor NRF560

KINAX WT720 absolute, programmable angular postion transmitter

General Specifications

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Sensor boxes SRBE Key features and product range overview

CombiView DFON Graphical display

Wall-/Pipe Mounted Universal Process Indicator

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Model DHH805 Handheld communicator. HART fieldbus tools Handheld configuration devices

Using the WirelessHART transmitter TTF300-W as repeater to extend the availability of a WirelessHART network

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Control IT Booster Pump Controller

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Series 3730 Type Electropneumatic Positioner

General Specifications

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Explosion Proof Weighing System

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Level-Lance Model 5400A

BA414DF Fieldbus indicator Single variable

T EN TROVIS Electropneumatic Positioner

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

FLEX Ex Spring Clamp Terminal Base

Conveyor Belt Alignment Switches from IDEM

Precision digital pressure gauge Model CPG1500

Linear Luminaire with LED Series 6412/5

SM2000 Videographic recorder Spare parts and upgrade kits

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

ExCos-P Pressure sensor 20 Pa Pa

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

100mm Process Indicator Recorder

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Load Disconnect Switches and Motor Switches

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

LS 6600 Technical Datasheet

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Series 3730 Electropneumatic Positioner Type

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Installation & Operation Manual

Continuous level measurement Radar transmitters

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

The iwap107 supports 100/1000Base-T, offering a significant increase in speed over the older fast Ethernet standard.

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive sensor NI3-EG08K-Y1-H1341

Technical Data. General specifications. Rated operating distance s n 3 mm

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

FICHA TÉCNICA DE PRODUTO

SM1000 Videographic recorder Spare parts and upgrade kits

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Precision digital pressure gauge Model CPG1500

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

ControlMaster CM10, CM30, CM50 and CM15 Universal process controllers and indicator Spare parts

SCADAPack Modbus multivariable transmitter

SITRANS F flowmeters SITRANS F US

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

LME620-AI/-AN (Contrac) Electrical Linear Actuator

Velomitor* CT Velocity Transducer

EX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom

Linear Luminaire with LED Series 6012/5

Inductive sensor BI1.5-EG08-Y1-H1341

ControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy

Transcription:

ABB MEASUREMENT & ANALYTICS DATA SHEET JDF200 Field Indicator

2 JD F 200 F IE LD IN D ICATO R DS /JDF200-E N RE V. G Measurement made easy Engineered solutions for all applications Digital LCD provides reliable and clear indications Flexible configuration facilities provided locally via local LCD keypad, with 1 or 2 lines numeric indication and Easy setup menu Signal characterization improves local indication by selectable transfer function Rugged, compact, lightweight, enclosure to IP67 and Nema 4x enables installation in industrial environments High reliability redundant acquisition system ensures enhanced dependability Comprehensive certification approvals give extended applicability in plant hazardous areas Compatible with all 4 to 20 ma, 2-wire systems Product in compliance with Directive 2011/65/UE (RoHS II)

JDF200 FIELD INDICATOR DS/JDF200-EN REV. G 3 Field indication as you need Model JDF field indicator provides simple and low cost remote indication of a process variable on an easy to read meter, ensuring the most useful display for any specific application. A reliable measurement is implemented by a redundant acquisition chain and by a diagnostic process that guarantee always the correct output value. In addition to parallel wiring to the transmitter, JDF200 allows series mode wiring, acting as junction box facility. JDF200 features a programmable signal display, providing alphanumeric plus bargraph indications: Two 5-digit numeric indication One graphic bargraph indication one 8-digit alphanumeric TAG indication a membrane keypad with 4 tactile feedback keys The functionality as METER is achieved by the graphic bargraph which gives an analog 0-100% indication and by the 5-digit display which gives a digital indication selectable from the following options: 4 to 20 ma 0 to 100% engineering unit Specification Functional Input range 4 to 20 ma nominal Operating range 3.2 to 23 ma (current less than 3.2 ma will blank the display) Maximum overload 400 ma up to 30 minutes Maximum voltage drop 2.4 V DC @ full scale range (5.6 V DC in case of hardware failure) Update time 0.5 sec. Transfer functions (input to indication) User-selectable for indication as linear or square root, power of 3 /2 or 5 /2, horizontal or spherical tank. Predefined 22 points linearization table available on request. Specification Operative limits Temperature limits C ( F) Ambient The operating temperature is: 20 to 70 C ( 4 to 158 F). Loop integrity is granted without damage to the field indicator in the range 40 to 85 C ( 40 to 185 F), with display not clearly readable or blank. IMPORTANT For Hazardous Atmosphere applications see the temperature range specified on the certificate/approval relevant to the aimed type of protection. Storage 40 to 85 C ( 40 to 185 F)

4 JDF200 FIELD INDICATOR DS/JDF200-EN REV. G...Specification Operative limits Environmental limits Electromagnetic compatibility (EMC) Comply with EN 61326-1. Surge immunity level: 2 kv (according to IEC 61000-4 5 EN 61000 4 5) Humidity Relative humidity: up to 100 % Condensing, icing: admissible Vibration resistance Accelerations up to 2 g at frequency up to 1000 Hz (according to IEC 60068 2 6) Shock resistance Acceleration: 50 g Duration: 11 ms (according to IEC 60068 2 27) Wet and dust-laden atmospheres The transmitter is dust and sand tight and protected against immersion effects as defined by IEC 60529 (2001) to IP 67 (IP 68 on request) or by NEMA Type 4X. Hazardous atmospheres Type of protection "Intrinsic safety": ATEX Europe (code E1) approval II 1G Ex ia IIC Tx Ga and II 1D Ex ta IIIC Tx Da IP67 and II 1D Ex ia IIIC Tx Da IP67 IECEx (code E8) approval Ex ia IIC Tx Ga and Ex ta IIIC Tx Da IP67 and Ex ia IIIC Tx Da IP67 Type of protection EXPLOSION PROOF : ATEX Europe (code E2) approval II 2G Ex db IIC Tx Gb and II 2D Ex tb IIIC Tx Db IP67 IECEx (code E9) approval Ex db IIC Tx Gb and Ex tb IIIC Tx Db IP67 Type of protection Type n and Intrinsically safe Ex ic : ATEX Europe (code E3 ) type examination II 3G Ex na IIC Tx Gc and II 3G Ex ic IIC Tx Gc and II 3D Ex tc IIIC Tx Dc IP67 IECEx (code ER) type examination Ex na IIC Tx Gc and Ex ic IIC Tx Gc and Ex tc IIIC Tx Dc IP67 Intertek US (code EV) and Intertek Canada (code EU): Explosionproof US: Canada: Non-sparking US: Canada: Intrinsically safe US: Canada: Enclosure type 4X Class I, Div. 2, Groups A, B, C, D T6...T4 Class II, Div 2 Groups F, G T6...T4 Class I, Zone 1 AEx d IIC T6...T4 Gb Class II, Div 1 Groups E, F, G T6...T4 Zone 20 AEx ta IIIC T85 C...T135 C Da Ex d IIC T6...T4 Gb Ex tb IIIC T85 C...T135 C Db Ex ta IIIC Tx Da IP67 Class I, Zone 2 AEx na IIC T6...T4 Gc Class I, Div 2 Groups ABCD T6...T4 Ex na IIC T6...T4 Gc Class I, Zone 0 AEx ia IIC T6...T4 Ga Class I, Division 1 Group A, B, C, D T6...T4 Class II, Division 1 Group E, F, G T6...T4 When connected per drawing No. DH3260 Class I, Division 2 Group A, B, C, D T6...T4 Class I, Zone 2 AEx ic IIC T6...T4 Gc When connected per drawing No. DH3260 Ex ia IIC T6...T4 Ga Ex ia IIIC T85 C...T135 C Da When connected per drawing No. DH3260 Ex ic IIC T6...T4 Gc When connected per drawing No. DH3260 COMBINED ATEX (code EW = E1 + E2 + E3), (code E7 = E1 + E2) COMBINED ATEX, Intertek, IECEx (code E5 = EW + EV + EU+ EI) COMBINED Intertek Approvals US and Canada Intrinsically safe (code EJ) Explosionproof (code EK) Nonincendive (code EL) COMBINED IECEx (code EH = E8 + E9), (code EI = E8 + E9 + ER) Kosha (Korea) Intrinsic Safety, Explosion Proof REFER TO CERTIFICATES OR OPERATING INSTRUCTIONS FOR AMBIENT TEMPERATURE RANGES (WITHIN THE LIMITS OF -50 TO 85 C) RELATED TO THE DIFFERENT TEMPERATURE CLASSES

JDF200 FIELD INDICATOR DS/JDF200-EN REV. G 5 Specification electrical characteristics and options Optional indicator Integral display with integral keypad (code L1) Wide screen LCD, 128 x 64 pixel, 52.5 x 27.2 mm (2.06 x 1.07 in.) dot matrix. Multilanguage. Four keys for configuration and management of device. Easy setup for quick commissioning. User selectable application-specific visualizations. Display may also indicate customizable diagnostic messages and provides configuration facilities. The indicator is user orientable, selecting one of 4 possible positions at 90. Indications The LCD display provides the following vizualizations: 8-digit alphanumeric for tag, in the top line (left corner) one line of 6-digit with height of 8 mm. or two lines of 8-digit with height of 5 mm., including decimal point, for numeric indication of variables, selectable between current or other 2 process values, plus relevant engineering units a bargraph of 30 mm. for indication of the input current signal in percentage with 0 to 100%.Environment Specification Performance specifications Stated at reference condition to IEC 60770 ambient temperature of 20 C (68 F), relative humidity of 65 %, atmospheric pressure of 1013 hpa (1013 mbar). Indication accuracy digital: ±0.10 % of span (16 ma) ± 1 digit. bargraph: ±1 % Resolution 16-bit conversion. Ambient temperature effect ±0.15 % of span (16 ma), for a temperature variation from 20 C (68 F) to the operating temperature limits of 20 or 70 C ( 4 or 158 F) Electromagnetic field Meets all the requirements of EN 61326-1. Specification Physical (Refer to ordering information sheets for variant availability) Materials Electronic housing and covers Aluminium alloy (copper content 0.3 %) with baked epoxy finish (colour RAL9002); AISI 316 L ss. Covers O-ring Buna N. Kit for pipe mounting AISI 316 L ss V-bolt with nuts and washers allowing installation on vertical and horizontal 60 mm. (2in) pipe. The field indicator housing provides 4 holes in the casting allowing wall mounting by 6 mm. dia. screws (not supplied). Plates Identification and certification plates: self-adhesive attached to the electronics housing or AISI 316 ss fastened to the electronics housing with rivets or screws. Optional wired-on customer data plate: AISI 316 ss. Laser printing on metal or thermal printing on selfadhesive. For AISI 316 L ss housing it is mandatory to select option I2 or I3 for plates in AISI 316 ss. Display (code Lx) 4-position (at 90 ) user orientable. Optional extras Metal plates (code Ix) Code I2: AISI 316 ss identification plate with laser printed tag (up to 31 characters) and scale details (up to 31 characters: lower and upper scale values and engineering unit) screwed to housing. AISI 316 ss certification plate fixed to housing by rivets. Code I1: AISI 316 ss wired-on plate with laser printed customized data (4 lines of 32 characters with 4 mm/0.16 in. height). Code I3 = I1 + I2. Design and calibration certificates (codes Cx) Tag and manual language (codes Tx and Mx) Electrical connection plug (code Z1) One certified stainless steel plug to match electrical connection thread

6 JDF200 FIELD INDICATOR DS/JDF200-EN REV. G...Specification Physical Electrical connections Two 1 /2 in. 14 NPT or M20x1.5 threaded conduit entries, direct on housing. Terminal block Three terminals for signal wiring up to 2.5 mm 2 (14 AWG), also with connection points for test and communication purposes. Grounding Internal and external 6 mm 2 (10 AWG) ground termination points are provided. Mounting position Indicator can be mounted in any position. Mass (without options) 0.9 kg approx (2 lb); add 0.1 kg (0.2 lb) for mounting kit; add 1.05 kg (2.3 lb) for AISI housing. Packing Carton 27 x 24 x 20 cm approx (11 x 10 x 8 in.).

JDF200 FIELD INDICATOR DS/JDF200-EN REV. G 7 Mounting dimensions (not for construction unless certified) dimensions in mm (inch) 121 (4.76) 91 (3.58) 130 (5.12) 18 (0.71) 100 (3.93) Space for cover removal 54 (2.13) 120 (4.72) 107 (4.21) 54 (2.13) 31 (1.22) 107 (4.21) 55 (2.17) 26 (1.02) Integral display housing Terminal side Certification plate Identification plate Figure 1 JDF200 dimentional drawing

8 JDF200 FIELD INDICATOR DS/JDF200-EN REV. G Dimensions Wiring as remote indicator Internal ground termination point TX + + _ External ground termination point Power source JDF200 field indicator 266 pressure trasnmitter NOTE This wiring as remote indicator is not applicable for 266 pressure transmitter with surge protection option code S2 NOTE JDF200 to be used as indicator with all devices ensuring minimum voltage drop on the ext. meter terminal Wiring as junction box Internal ground termination point External ground termination point TX + + _ Power source 266 pressure trasnmitter JDF200 field indicator Figure 2 JDF200 Wiring drawings

JDF200 FIELD INDICATOR DS/JDF200-EN REV. G 9 Ordering Information Basic ordering information model JDF Field Indicator Select one character or set of characters from each category and specify complete catalog number. Refer to additional ordering information and specify one or more codes for each instrument for required additional options. Base model - 1st to 6th characters Field Indicator Housing material and electrical connection - 7th character J D F 2 0 0 X X Aluminium alloy 1/2 in. 14 NPT A Aluminium alloy M20 x 1.5 (CM 20) B AISI 316 L ss (I2 or I3 additional code required) 1/2 in. 14 NPT S AISI 316 L ss (I2 or I3 additional code required) M20 x 1.5 (CM20) T AISI 316 L ss painted (I2 or I3 additional code required) 1/2 in. 14 NPT C AISI 316 L ss painted (I2 or I3 additional code required) M20 x 1.5 (CM20) D Input signal/additional options - 8th character 4 to 20 ma Options requested by Additional ordering code 7

10 JDF200 FIELD INDICATOR DS/JDF200-EN REV. G...Ordering information Additional ordering information for model JDF200 Add one or more 2 digit code(s) after the basic ordering information to select all required options. XX XX XX Integral LCD Digital LCD integral display with integrated keypad L1 Hazardous area certifications ATEX Intrinsic Safety II 1G Ex ia IIC Tx Ga and II 1D Ex ta IIIC Tx Da IP67 and II 1D Ex ia IIIC Tx Da IP67 E1 ATEX Explosion Proof II 2G Ex db IIC Tx Gb and II 2D Ex tb IIIC Tx Db IP67 E2 ATEX No sparking and Intrinsic Safety II 3G Ex na IIC Tx Gc and II 3G Ex ic IIC Tx Gc and II 3D Ex tc IIIC Tx Dc IP67 E3 Combined ATEX - Intrinsic Safety, Explosion Proof and No sparking Ex na and Intrinsic Safety Ex ic (E1 + E2 + E3) EW Combined ATEX - Intrinsic Safety and Explosion Proof (E1 + E2) E7 Combined ATEX, IECEx, Intertek (USA) and Intertek (Canada) (PENDING) (EW + EV + EU + EI) Note A E5 Intertek (Canada) approval EU Intertek (USA) approval Note A EV Intertek (USA and Canada) Intrinsic Safety and Dustproof Note A EJ Intertek (USA and Canada) Explosion Proof Note A EK Intertek (USA and Canada) Nonincendive Note A EL IECEx Intrinsic Safety Ex ia IIC Tx Ga and Ex ta IIIC Tx Da IP67 and Ex ia IIIC Tx Da IP67 E8 IECEx Explosion Proof Ex db IIC Tx Gb and Ex tb IIIC Tx Db IP67 E9 IECEx No sparking and Intrinsic Safety Ex na IIC Tx Gc and Ex ic IIC Tx Gc and Ex tc IIIC Tx Dc IP67 ER Combined IECEx - Intrinsic Safety, Explosion Proof and No sparking Ex na and Intrinsic Safety Ex ic (E8 + E9 + ER) EI Combined IECEx - Intrinsic Safety and Explosion Proof (E8 + E9) EH Kosha (Korea) Intrinsic Safety Ex ia IIC, ExiaD 20, Ex td A20, IP67 WM Kosha (Korea) Explosion Proof Ex d IIC, Ex td A21, IP67 WN Combined Kosha (Korea) - Intrinsic Safety and Explosion Proof WP Operating manual (multiple selection allowed) German M1 Italian M2 Spanish M3 French M4 English M5 Chinese M6

JDF200 FIELD INDICATOR DS/JDF200-EN REV. G 11 ADDITIONAL ORDERING INFORMATION for model JDF200 XX XX XX XX XX Plates language German Italian Spanish French Tag plates Supplemental wired-on stainless steel plate Identification and certification stainless steel plates Identification, certification and supplemental wired-on stainless steel plates Temperature Limit (mandatory for US Certifications) Installation to be performed down to -40 C (-40 F) ambient temperature Installation to be performed in an extended range down to -50 C (-58 F) ambient temperature Certificates (multiple selection allowed) Inspection certificate EN 10204 3.1 of calibration (9-point) Certificate of compliance with the order EN 10204 2.1 of instrument design Electrical connection plug One certified stainless steel plug (supplied loose) T1 T2 T3 T4 I1 I2 I3 NB NC C1 C6 Z1 Note A: US Certifications require additional digit selection under Temperature Limit characteristic. For applications performed at ambient temperature range down to -50 C (option NC ) it is mandatory to permanentely protect window cover from accidental impact before installing (see specific details in the instruction manual OI/JDF200) Standard delivery items (can be differently specified by additional ordering code) Self-adhesive plastic labels in English General purpose (no hazardous area certification) Kit for pipe mounting Operating instruction manual and labels in english (self-adhesive) No inspection certificate No electrical connection plug

ABB Ltd. Measurement & Analytics Howard Road St. Neots Cambridgeshire PE19 8EU UK Tel: +44 (0)1480 475321 Fax: +44 (0)1480 217948 ABB S.p.A. Measurement & Analytics Via Luigi Vaccani 4 22016 Tremezzina (CO) Italy Tel: +39 0344 58111 ABB Inc. Measurement & Analytics 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2018 ABB All rights reserved 3KXP726002R1001 DS/JDF200-EN Rev. G 12.2018