Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

Similar documents
Environmental Conditions

MP211 HARDWARE MANUAL

Quick Installation Guide

UR72 & UR75 Industrial Cellular Router

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide

HARDWARE MANUAL MMS100. M-BUS TO MODBUS GATEWAY Series 07 / 2017 MIKRODEV_HM_MMS100_EN

OnCell G3100 Series Quick Installation Guide

iologik 2500 HSPA/GPRS/WLAN Series

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Panoramic Power Installation and configuration guide

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Installation and Configuration Quick Guide. R3000 Quad. Industrial Cellular VPN Router with 4 Ethernet Ports (4 Eth + 1 RS-232/1 RS USB Host)

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents

NetBiter Serial Server User Manual

KX ROUTER 4G WIFI PRO VPN

UR51 Industrial Cellular Router

QUICK START G U I D E. GWG Gateway GWG-30, GWG-40

Netbiter EC300 Series

802.11n Wireless. ADSL 2/2+ Router ADN Quick Installation Guide

Ethernet Interface Module

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Installation and Configuration Quick Guide

User manual Compact Web PLC WP240 series IEC-line. update:

iologik 2500 HSPA/GPRS/WLAN Series

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host.

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

RTU300 SERIES HARDWARE MANUAL

NetComm Commercial. NetComm NTC-6000 CallDirect Series HSPA Cellular Routers Quick Start Guide

3.1 Updating Web Package Updating OS... 16

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

IGAR G is a reliable IEEE a/b/g/n WLAN VPN router with 2 ports 10/100/1000Base-T(X) router where

Quick Start Guide REX 100 3G LTE. Version. 2 en. as of FW

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

R O U T E R М Т 0 1 V e r s i o n v А Т O M e v e r i t h i n g n e w e m e r g e s n o w

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

User Manual Anybus Serial Server

NetComm NTC-5000 CallDirect Series HSPA Cellular Routers Quick Start Guide

icex-cmtm General specs and Installation guide

Turck Cloud Gateway UMTS Gateway TCG20-UMTS-1ETH-CRS-01

VIRTUALSCADA. CommunicatewithAnyDeviceAnywhereatAnytime. SCADAServerUserManual EC150/VS150 EC220/VS220 EC250/VS250 EC310/VS310 EC350/VS350. Rev:2.

User Manual Edition: v a

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

InRouter600-S Series 4G LTE or 3G, WI-FI, VPN Industrial Router

3G Router 431R/421R/321R/311R/221R/211R. Quick Start Guide

Features and Benefits. Certifications

SXPi Linux box version 1.0

IG601 Intelligent Gateway Quick Guide

Ursalink UR55 Industrial Cellular Router Datasheet

SEVIO User Guide. Document ID: sv_user_guide_en_v17_05

iologik 2500 Series Quick Installation Guide

Reliable and Remote-Manageable for Large Scale M2M Deployment

WRM 247+ QUICK GUIDE

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

Baltos ir Contact Online. More Pictures. Click on the thumbnails for the large picture

Wireless Solutions. 5.1 Wireless LAN & Wireless Modem. Wireless Modems. Intelligent GPRS/GSM Modules. Mini-Programmable Automation Controllers

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

WBD-222. Hardware Manual. Revision September Copyright 2010 WILIGEAR

gridcomm GC1310 Master Light Controller Hardware Installation Guide

3G/4G OUTDOOR ROUTER Instruction Manual

Hardware Installation

KX/3G ADSL2+ ROUTER MAIN FEATURES

BROADBAND 3G/4G MODEM Instruction Manual

Features and Benefits. Certifications

NETCOMM GATEWAY SERIES Dual ADSL2+ / 3G Wireless N Gateway. 3G29WN2 Quick Start Guide

Industrial Serial Device Server

Alekto 2. Contact Online. More Pictures. Klick on the thumbnails for the large picture

Zavio P5111/ P5116/ P5210 Quick Installation Guide

NTC-30WV-03. Outdoor Industrial Router. December 2012

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

GenIP : Intelligent gateway dedicated to most critical industrial applications

Smart Sensor Gateway Installation Manual

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

MF10 3G Wireless Router

MOBILE BROADBAND FOR SMART METERS

-SMS Alert Gateway. EzSMS-Lite USER S MANUAL

User Manual Anybus Modbus TCP/RTU Gateway

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

LogicMachine5 Reactor GSM

SysLINK 1000/1500 Family Quick Start Guide

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

RM6000 GPRS Modem / Router

WAVE-4G-GPS. Technical Specifications Sheet. Waveloc IT Solutions LTD. Wave-4G-GPS Technical Specifications Sheet

TGAR G-M12 series

Hardware Specifications

Quick Start Guide BEC G/LTE Outdoor Router

WLAN Products 2.1 Overview P WLAN Remote Maintenance Device P WLAN Converter P Applications P2-4-1

+70 C -25 C 95% RH EMC

Quick Start Guide NTC-40 Series - M2M WiFi Router

Quick Installation Guide DSL-2650U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522

EAP150 EAP150. Long Range Ceiling Mount Access Point PRODUCT OVERVIEW

Transcription:

1 (http://nethix.com) Portal (../portal/portal.html) WE110 (../we110/we110.html) WE120 (../we120/we120.html) WE300 (../we300/we300.html) WE500 (we500.html) Quick start guide (we500_qsg.html) Hardware manual () 1. Overview 2. Technical characteristics 3. Connections 3.1. Top connector 3.2. Bottom connector 3.3. Front panel 4. Installation 4.1. SIM card and connections 4.2. System start-up 4.3. Logging in the web interface 5. Power off and reboot 6. Stand-by mode 6.1. Entering the Stand-by mode 6.2. Leaving the Stand-by mode 7. Network recovery Software Manual (we500_sw_manual.html) Plugins (we500_plugins.html) Application notes (we500_app_notes.html) Hardware manual 1. Overview 2. Technical characteristics 3. Connections

2 3.1. Top connector 3.2. Bottom connector 3.2.1. Connector electrical characteristics 3.3. Front panel 4. Installation 4.1. SIM card and connections 4.2. System start-up 4.3. Logging in the web interface 5. Power off and reboot 6. Stand-by mode 6.1. Entering the Stand-by mode 6.2. Leaving the Stand-by mode 7. Network recovery 1. Overview The WE500 is a remote monitoring, data logging and system control device based on GSM/UMTS wireless networks that allows to continuously monitor unmanned processes and to remotely control devices and electronic systems. The WE500 provides a built-in web server that allows the configuration, monitoring and system control of a given device through a LAN, WLAN or GPRS/HSPA connection. The WE500 is a powerful wireless generic platform with the following characteristics:

3 2. Technical characteristics Characteristic CPU RAM Flash Operating System Ethernet Modem CPU ARM9 AT91SAM9260 @ 210MHz 64 MBytes 1 GByte NAND Linux 2.6 10/100 Mbit/s 3G 14.4Mbps downlink / 5.76Mbps uplink (HSPA) Quad band GSM/GPRS/EDGE Quad band HSDPA/HSUPA 2G Quad band GSM/GPRS Dual modem 3G + 2G with above characteristics Communication 2 RS232 serial ports 1 RS485 serial port Digital inputs Analog inputs 8 inputs, non isolated, dry contact 2 inputs, non isolated, 0-5V, 0-10V 0..20mA (configurable for 4..20 ma), NTC 10K Digital outpus 2 relays, 1A 30VDC

4 Characteristic Power source Average absorption Peak absorption Weight Dimensions (L x W x H) Box Storage temperature Working temperature Humidity 9-32 VDC 300 ma @ 12VDC 500 ma @ 12VDC 275 gr 45 x 120 x 100 mm Plastic, DIN bar mountable -25 C - +85 C -10 C - +60 C 5% - 95% (non condensing) If the analog inputs are 0..20 ma, they can be used in the 4..20 ma by simply setting an offset when configuring the analog input. 3. Connections

5 Connector 1 Top connector Pluggable screw terminal, 10 poles, 3.81 mm step 2 Bottom connector Pluggable screw terminal, 20 poles, 3.81 mm step 3 RF SMA antenna connector 4 SIM card slot 5 Ethernet 10/100 MB/s RJ-45 connector 6 Front panel button 3.1. Top connector Connector RX1 TX1 RX2 for UART1 RS232 RX UART1 RS232 TX UART1 for UART2 RS232 RX UART2

6 Connector TX2 RS232 TX UART2 for RS485 B RS485 signal B ( - ) A RS485 signal A ( + ) +VAUX +5VDC out The Pluggable screw terminals are listed from the front to the back of the device. 3.2. Bottom connector Connector Digital inputs ground DI1 Digital input 1 DI2 Digital input 2 DI3 Digital input 3 DI4 Digital input 4 Digital inputs ground DI5 Digital input 5 DI6 Digital input 6 DI7 Digital input 7 DI8 Digital input 8 Analog inputs ground AN1 Analog input 1 Analog inputs ground AN2 Analog input 2 Power source ground

7 Connector +VIN Power source input +VDC RL1A Relay 1 RL1B Relay 1 RL2A Relay 2 RL2B Relay 2 The pluggable screw terminals are listed from the front to the back of the device. 3.2.1. Connector electrical characteristics Power source Polarized VDC input, with internal protection diode compatible with the following tension rate: Vnom = 12VDC [9.6V 32V] Analog input Factory configured non isolated Analog Inputs Admissible input range: 0 5 V 0 10 V 0..20 ma (4..20 ma configurable via software) NTC Digital input Dry contact, non isolated, low tension Digital Input

8 Error These inputs were design to operate at low tensions, avoid to connect them directly to 230VAC network. Relays Relay load: 1A at 30VDC Error Avoid to connect them directly to 230VAC network. Serial ports There are three serial ports: Serial 1: Standard RS 232 Serial 2: Standard RS 232 Standard RS 485 3.3. Front panel (../_images/front_panel1.png) LED GPRS HSPA/GPRS connection Turned on when the HSPA/GPRS data connection is active MODEM Modem activity Turned on when the modem is active, even if there is no data connection active.

9 4. Installation This chapter describes the installation procedure and first device start up. In order to have a normal operating device, it is necessary to have a SIM card that allows to establish an HSPA/GPRS data connections. Please check the carrier s data planning for prices and costs of the service. Verify that the device is installed in a physical position in which it receives sufficient 2G/3G network coverage. Note The device has been tested and verified with SIM cards of the major European carriers such as Vodafone (Italy), T-Mobile (Germany) and O2 (Ireland). It has also been used with SIM cards of carriers in different parts of the world such as Africa and Asia. However, there is no warranty that it will work with all the existent SIM cards in the market. Please contact Nethix for further information. 4.1. SIM card and connections Insert the SIM card in the WE500 as the image shows. The SIM card contacts must face the pluggable screw terminal and the cut angle faced to the front of the device. Avoid to insert the SIM card when the device is turned on. After turning off the device and removing the power source, the SIM card can be inserted/removed.

Mount the WE500 in a DIN bar allowing access to the SIM card and the pluggable screw terminals. Prepare the input and output connections to the pluggable screw terminals as required by the application. If required, connect the modbus cables using the signals TX1, RX1 and or TX2, RX2 and or A, B, for the RS232 A, RS232 B or RS485, respectively. Connect a quad band GSM antenna with the right cable and, if required, the extension being sure to have a satisfactory GSM signal. Check the network coverage with any mobile phone. Connect to the pluggable screw terminals the +VIN and of the bottom connector to an adequate power source. The digital inputs are not galvanic isolated, they have an internal pull-up and are activated by closing the circuit with through a dry contact. The analog inputs are not galvanic isolated. If necessary, for avoiding interference, analogical isolators can be placed externally. 4.2. System start-up 1. The POWER LED will turn on when the WE500 is connected to the power source. 2. After ~40 seconds, the RUN and BUS LEDs will turn on. At this point all the application and services will be active. The monitoring, control and logging applications will be running and the web interface will be reachable. 3. After ~30 seconds of step 2, the HSPA/GPRS service will become active and the GPRS LED will turn on. The services that depend on this connection such as VPN, data delivery to a portal and email will be active. The initial WE500 configuration must take place locally in one of the two following modes: 10

11 Point-to-point connection between the PC and the WE500 using a normal or cross Ethernet RJ-45 cable: LAN wired connection through a switch or hub: The default network configuration of the WE500 is the following: Parameter Value IP address 192.168.1.160 Netmask 25.255.255.0 Gateway 192.168.1.1 DNS 8.8.8.8 4.3. Logging in the web interface In order to establish a connection enter the IP address of the device in the browser s URL: http://192.168.1.160 (http://192.168.1.160) The default credentials are: Username admin Password admin Hint It s strongly recommended to change the default

password after the first login. It s necessary that the PC belongs to the same subnet of the device. In this case the private network 192.168.1.X. For connecting to the WE500 a standard Internet browser is needed. No drivers or specific software are required. The recommended browsers that were also used for validating the web-interface are Firefox and Chrome. However, other browsers are known to work properly. Successive access to the web interface can take place through different channels assuming that the device is properly configured: LAN ADSL WLAN HSPA/GPRS VPN The VPN can use any of the above channels to establish a secure connection between the WE500 and the PC. It needs a client software in the PC and 12

13 a server that provides the service such as the Nethix Portal (http://nethix.com/en/products /portal). 5. Power off and reboot Powering off the WE500 can be done in two ways: 1. Using the proper icon at the right top of web interface. Only an administrator can power off or reboot the device. 2. Using the Stand-by mode described later. Error Powering off the device by removing unexpectedly the power source could cause data loss or corruption. 6. Stand-by mode The Stand-by functionality turns off all the system applications, such as the web server and the variables monitoring, setting the system to a low power consumption state. This functionality must be always used before removing the power source from the device. Not doing so, could cause data loss or corruption. 6.1. Entering the Stand-by mode For entering the Stand-by mode, press the front panel button and leave it pressed for approximately three seconds. During this time, the power LED will blink fast, then all the LEDs will blink together indicating that the system will enter the Stand-by mode When the LEDs start blinking together fast, release the button immediately. The power LED will turn-on again for several seconds and start blinking again slowly, approximately once every two seconds, indicating that the system has entered the Stand-by mode and that is in a low power consumption state.

14 The whole procedure takes approximately fifteen seconds. Notice that leaving the front panel button pressed after all LEDs blink three times starts the network recovery procedure. 6.2. Leaving the Stand-by mode When in Stand-by mode, the power LED blinks slowly, approximately once every two seconds. Press the front panel button and leave it pressed. The power LED will start blinking fast for approximately three seconds, then it will remain turned-on. At this point the button can be released and the system will start-up normally. 7. Network recovery For executing a Network Recovery, press the front panel button and leave it pressed for approximately six seconds. During this time the following actions will be executed twice: * The power LED will blink fast for approximately 3 seconds * Then, all the LEDs will blink together three times After these six seconds, the power LED will turn-on and start blinking again slowly, approximately once every two seconds, indicating that the network recovery has been executed and the system is in Stand-by mode. Execute the procedure for leaving the Stand-by mode for booting the device normally. This is the default network configuration after the Network Recovery: Parameter Value IP address 192.168.1.160 Netmask 25.255.255.0 Gateway 192.168.1.1

15 Notice that the Network Recovery procedure is applied only to the Ethernet interface and not to the Wi-Fi or GPRS/HSPA interfaces. nethix.com (http://nethix.com) Back to top Copyright 2015, Nethix Srl.