User. Manual. cmt-hdm Startup Guide. Weintek USA, Inc. (425)

Similar documents
User. Manual. cmt-fhd Startup Guide. Weintek USA, Inc. (425)

cmt Quick Start Guide

User. Manual. cmt-3103 Wireless Network Settings Guide. Weintek USA, Inc. (425)

4-1. This chapter explains HMI settings.

4-1. This chapter explains HMI settings.

cmt-g01 with OPC UA Server and Modbus Gateway

cmt-g04 with OPC UA Server and MQTT Sparkplug B cmt-g04 with OPC UA Server and MQTT Sparkplug B

SQL Synchronization and SQL Query to MS SQL Database. SQL Synchronization and SQL Query to MS SQL Database

13-1. This chapter explains how to use different objects.

User Manual. cmt-svr Startup Guide

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Weintek HMI to Control Techniques M400 AC Drive via Modbus TCP/IP Ethernet Module

3.1 Updating Web Package Updating OS... 16

EasyBuilder 8000 Version

Firmware User Manual. Firmware version v1.0. Suitable for Product Series: Touch Panel PC Panel PC Box PC. QD-FW_Manual_v1.0

WISP Setup Guide for TP-Link TL-WR841N 300 Mbps Wireless N Router AARP Foundation Tax-Aide Colorado Technology Specialist

Setup Guide for Hard-Wire Ethernet Connected TP-Link TL-WR841N 300 Mbps Wireless N Router AARP Foundation Tax-Aide Colorado Technology Specialist

1. Introduction P Package Contents 1.

User Manual. cmt-svr Startup Guide

Nextiva Drive The Setup Process Mobility & Storage Option

This handbook contains important security measures and product information, to help avoid accidents. Please

IdeaTab A1000L-F. User Guide V1.0. Please read the Important safety and handling information in the supplied manuals before use.

ST-HD-CVR4CH ST-HD-CVR8CH ST-HD-CVR16CH. Professional Digital Video Recorders QUICK START GUIDE

EasyBuilder Pro V screen and editing the project with the Work Space window open.

hp l1619a smart attachment module

HomeTroller Zee S2 Getting Started Guide

1. Introduction P Package Contents 1.

Using AORUS Notebook for the First Time

State of the art hyper-optimized video management platform designed for ease, speed and efficiency. Blackjack BOLT-LX

Amcrest 960H DVR Quick Start Guide

Instruction Manual. Wi-Fi Full HD 1080p IP Concealed Junction Box Hidden Camera. V 1.3

EasiShare ios User Guide

EasyBuilder Pro V This model is a gateway device; therefore, it is not possible to generate a

Welcome to Playlist, the world s easiest to use digital signage software

Table Of Content 1. What s in the box 3 2. About the unit 4 3. Getting started 5 4. Networking options 6 5. Turning on the MTC-5000 Unit 7 6.

SAS Mobile BI 8.1 for Windows 10: Help

Touch Screen Digital Signage (Network) User Manual

DENT Instruments ELITEpro Mobile App

M73 Series Network Projector Operation Guide

AMC Manager User's Manual

AM-101 AM-101AirMedia Presentation Gateway. Supplemental Guide Crestron Electronics, Inc.

VEGA. Operation Manual T A B L E T P C. advent vega operation manaul_new.indd 1

Network Digital Menu Board Hardware User Manual

NovoConnect B360. Wireless Presentation & Collaboration System. User Manual Version 0.98

HomeTroller SEL Getting Started Guide

8-1. This chapter explains how to set and use Data Sampling.

Quick Installation Guide

Wireless HDMI Display Receiver User s Manual

POS Android Digital Advertising Display (Network) Hardware User Manual

Multi-NVR Manager. Quick Start Configuration Usage

10.User Password and Object Security

Tablet PC User Manual

Remote Access Application Viewer User Guide. Version 2.3

PDF Expert for ipad User guide

DMS Local. User Manual. For Projector Management V 1.01

NovoConnect B360. Wireless Presentation & Collaboration System. User Manual Version 0.99

Atlona Manuals Software AMS

Remote Access Application Viewer User Guide. Version 2.5

HD Ovi Digital Clock WiFi Hidden Camera. User s Guide WHEN YOU NEED TO KNOW.

HomeTroller S6 Quick-Start Guide

User Manual. pdoc Pro Client for Windows. Version 2.1. Last Update: March 20, Copyright 2018 Topaz Systems Inc. All rights reserved.

Using AORUS Notebook for the First Time

Setup and Configuration

Battery Charging The tablet has a built-in rechargeable Li-polymer battery.

User Manual. cmt-iv5 Startup Guide

Amcrest 650 TVL DVR Quick Start Guide

ASUS AIMESH SETUP GUIDE

Network Camera Firmware Upgrade Quick Guide

Windows quick start instructions Pg. 1. OS X quick start instructions Pg. 4. ios quick start instructions Pg. 6

Technoversity Tuesdays

CyberDiscovery User Guide Version 0.1

JOOAN Wireless Network Camera

Catalogue. Assembling... 1 Unpack Charge the Battery Install the Memory Card Product Basics Buttons and Connections...

Amcrest Eco HDCVI DVR Quick Start Guide

StatMonitr Screen. Operating Your StatBroadcast. On Game Day (Mark V Model Surface RT)

SAS Mobile BI 8.15 for Android: Help

User Manual. BioTime Web

Using AORUS Notebook for the First Time

ShareLink 200 N Setup Guide

Do not place or mount Ocli 1 in an area where it will be exposed to water. Ocli 1 is designed for indoor use.

HooToo IP Camera User Manual(part two)

College of Pharmacy Windows 10

SAS Mobile BI 8.14 for ipad and iphone: Help

Using the SHARP touchscreen

EC-11 Ethernet Converter

Table of Contents. Manual Overview

SC550W WIFI IP HIDDEN CAMERA

ShareLink 200 N Setup Guide

Aimetis Thin Client 2.7. User Guide

User Manual For AT-100BW/200BW

Lutron Home Control+ App for the Apple ipad TM, iphone TM and ipod touch

INNOV.NET PTY LTD. User guide

Point of View SmartTV-500 Center - Android 4.2. General notices for use...2 Disclaimer...2 Box Contents...2

Bush Baby Wi-Fi Wall Outlet Hidden Camera

IPC Online Operation Manual

WebStation User Manual

uremote User Manual Version 1.3 Jan 2017

Operating Instructions. Windows. Video Wall Adjustment & Calibration Software. Video Wall Manager Ver. 1.8

X-Sign 2.0 User Manual

3G WIFI ROUTER/POWERBANK Quick Guide

Transcription:

User Weintek USA, Inc. www.weintekusa.com (425) 488-1100 Manual cmt-hdm Startup Guide The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. Rev. Dec 7 2018

Table of Contents 1. Supported Touch Screen 3 2. Network Wiring Diagram 4 3. Setup... 5 4. Web Interface... 16 5. How to Load a Project via USB Drive... 19 6. How to Retrieve Historical Data via USB Drive... 20 7. How to Delete All Historical Data... 21 8. OS Upgrade... 22 9. How to Calibrate Resistive Touch Screen.. 24 10. How to Adjust the Resolution of cmt-hdm. 25 11. cmt-viewer. 27 12. Monitor Mode 35 13. cmt-viewer Limitations.. 39 14. cmt Objects Introduction. 41 15. cmt-hdm Gestures Operation 48

1. Supported Touch Screen The following industrial touch screens are verified to be compatible with cmt-hdm. Brand Name Model Touch Screen Type Screen Size (Inch) Requires OS Version of cmt- HDM IEI DM-F22A/PC-R11 USB projected capacitive touch 21.5" 20171208 or greater Aplex ARCDIS-121AP USB projected capacitive touch 21.5" 20171208 or greater Indumicro IMD-C220PT USB projected 21.5" 20171208 or Hope Industrial Systems HIS-ML19.5-CTBA capacitive touch USB analog resistive touch greater 19.5" 20180523 or greater ELO ET1590L-7CWB-1-ST-NPB-G USB AccuTouch 5- wire Resistive Touch 15" 20180523 or greater ELO ET1593L-2UWB-0-MT-ZB-NPB-G TouchPro PCAP 15.6" 20180523 or greater ELO ET2094L-8CWB-0-ST-NPB-G USB IntelliTouch 19.5" 20180523 or greater Weintek cmt-im21 Capacitive touch 21.5" 20171208 or greater

2. Network Wiring Diagram Connect a cmt-hdm to a router via an Ethernet cable as the diagram shows below. The default IP address of LAN 1 is DHCP. The default IP address of LAN 2 is static IP 192.168.100.1. The IP addresses of LAN 1 and LAN 2 must be configured to the different subnets. cmt-hdm LAN Ports: cmt-hdm HMI is equipped with two independent Ethernet ports which isolates the device network from the company/factory network. LAN1 is a WAN (Wide Area Network) port which is allowed to connect to a public network or another network via a gateway. LAN2 is a LAN (Local Area Network) port.

3. Setup Press the system toolbar button at the upper left of the screen to open Setup. Information This page shows general information about cmt-hdm and network information.

Language Select a language for Setup. The language selected on the project of the cmt-hdm won t be changed by this setting. Input Method Select languages for system keyboard input use.

Reset Options This page is used to reset cmt-hdm to the factory default setting. Press [Start] to reset if needed. Enter yes into the box and click on [OK] to start reset process.

Advanced Settings To access more system settings, click on the lock icon at the top left corner. There are two different levels of password protection. Select [System Setting] and enter System Setting password. The default password of System Setting is 111111. The OS Upgrade tab will be accessible to System Setting. After clicking on [OK], the icon will become unlocked. General [Direction]- Click on the button to change the direction of the screen display. [Popup download window]- If enabled, after inserting a USB drive to the USB port of the cmt-hdm, the Upload/Download dialog window will pop up. [FTP Port]- Click the > button to change FTP port number. [FTP client can modify USB/SD data]- If enabled, historical data stored in USB drive can be modified via FTP(File Transfer Protocol).

Network Set the IP addresses of Ethernet 1 and Ethernet 2. The default IP address of Ethernet 1 is DHCP. The default IP address of Ethernet 2 is 192.168.100.1. The IP addresses of Ethernet 1 and Ethernet 2 must be on the separate subnets. Click on one of the > button. Enable [Obtain an IP address automatically] (DHCP) or set the IP address manually (Static IP).

Time/Date Adjust cmt-hdm RTC manually.

HMI Name Change the name of cmt-hdm to identify this HMI when retrieving historical data or loading a project on a PC. This saves time remembering the IP address of each cmt-hdm. Clear History This page is used to clear historical data, recipe, and database stored in the internal memory of cmt-hdm.

Project Management Restarts the project of the cmt-hdm and restores it to its initial state without cycling power. System Password There are three different levels of password protection, User, Update Project, and System Setting. This page is used to change the passwords for operating a project via cmt viewer, loading a project to the HMI, accessing FTP server and so on. The default passwords of the three levels are 111111. [User]- This level can operate cmt projects via cmt viewer. [Update project]- This level can load and retrieve the HMI project, as well as retrieve historical data, such as data log and event log. In addition, it can operate cmt projects via cmt viewer. [System Setting]- This level has access to change all system settings, load and retrieve the project, retrieve historical data, and operate cmt projects via cmt viewer. It is the highest level. [History]- FTP server access. The default password is 111111. Password hierarchy - System setting -for administrator Update projectfor supervisors User- for operators

Enhanced Security (Objects authorized to operators in HMI project) This function provides user passwords and security classes to prevent unauthorized operators from accessing objects such as the Motor Start button in cmt-hdm project. For more information, refer to the section 5.6.2 Enhanced Security Mode in Easybuilder pro user manual.

VNC Setting The VNC server provides remote HMI monitoring and controlling via Ethernet connection. [Start VNC]- It allows VNC connection with only one VNC client. [VNC multi connection]- It allows connection with multiple VNC clients. Connecting the VNC server to too many VNC clients may slow down the communication speed and HMI performance. [VNC login password]- Specify a password. Logging in the VNC server will require the password. EasyAccess2.0 EasyAccess 2.0 is a tool that allows users to access the screen of cmt-hdm remotely around the world. cmt-hdm is NOT a pre-licensed model, so purchasing a activation card is necessary. For more information, refer to EasyAccess2.0 user manual.

OS Upgrade This page is used to upgrade the firmware of cmt-hdm.

4. Web Interface Configuring Setup of the cmt-hdm via a web browser is available. Before configuration, connect cmt-hdm (LAN1) to a router via an Ethernet cable. Open a web browser (IE, Chrome, or Firefox) and enter the IP address of the cmt-hdm. For example, enter 192.168.1.15. Select an identity and enter its password. The tabs of the web interface are displayed as shown. They are Network, Date/Time, HMI Name, History, Email, Project Management, System Password, Enhanced Security, EasyAccess2.0, and Touch Calibration.

Feature Introduction Date/Time [Sync with host.] - Synchronizes the HMI RTC with the PC RTC. To confirm the action, click on [Save]. History [Clear]- It is used to clear historical data, recipe, and database stored in cmt-hdm. Select boxes that need to be cleared, and click on [Clear]. [Backup] - Select boxes to transfer historical data or recipe files from the cmt-hdm to the PC and click on [Download].

Project Management [Restart Project] - Restarts cmt-hdm and restores it to its initial state. [Update Project]- Loads a project and recipes from the PC to cmt-hdm. [Backup Project]- Retrieves a project from cmt-hdm to the PC.

5. How to Load a Project via USB Drive (USB Drive ->HMI) Step 1. Use [Build Download Files] function to build *.cxob file into a USB drive. Step 2. Plug the USB drive into to the USB port of cmt-hdm. When a window pops up for download/upload, click on [Download]. Step 3. Enter the password. The password requires the levels of Update Project or System Setting. Step 4. Step 5. Navigate to the folder containing *.cxob file and highlight it. Click on [Download] to start.

6. How to Retrieve Historical Data via USB Drive (HMI-> USB Drive) Step 1. Plug a USB drive to the USB port of cmt-hdm. A window will pop up for download/upload, and then click on [Upload]. Step 2. Select logs and enter the password. The password requires the levels of Update Project or System Setting. Step 3. Specify a folder path for storing historical data.

Step 4. Click on [Upload] to start. 7. How to Delete all Historical Data Step 1. Return to this main page and click on [Download]. Step 2. Enter the password and select logs you want to delete. The password requires the levels of Update Project or System Setting. Click on [Download] to start.

8. OS Upgrade Step 1. Copy the new OS image to a designated folder in a USB drive. In this demonstration, I create a folder named OS_cMT_HDM, and place the OS image onto the folder. The OS image takes the form of a *.bin file. Step 2. Plug the USB drive into the USB port of cmt-hdm. If a window pops up and prompts you to download or upload, click close to dismiss it. Step 3. Press on the button Step 4. Press on the lock icon on the screen. and choose *System Setting+. Enter the correct password to gain access. The default password is 111111. Step 5. Scroll down and find *OS upgrade+ tab.

Step 6. Click on the folder symbol, and then navigate to the folder containing the OS image. In this demonstration, locate the folder OS_cMT_HDM, highlight the image, and then click *OK+. Step 7. Click the *Upgrade+ on the top right corner. OS upgrade will begin, which may take a short while. Do not unplug the power cable during OS upgrade. It may result in all data being lost. The progress bar indicates the progress of the OS upgrade. Reboot the HMI by following the instructions shown on the screen.

9. How to Calibrate Resistive Touch Screen 1. Connect the touch screen to the USB port of the cmt-hdm via USB cable. 2. Open a web browser on a laptop. Make sure both the laptop and the cmt-hdm have connected to the router via Ethernet cables. 3. Log in the web interface with the correct password. The default password is 111111. 3. Go to [Touch Calibration] tab. 4. Click on [Start calibration] button to start Calibration process. Note: If you are required to update the driver of the touch screen, click on the [Update Driver] button. The pop-up window will prompt you to select a *.bin file. 5. The touch screen will enter the calibration mode. Press the target sign shown in the corner of the screen.

6. When the window pops up, drag the sign into [OK] box in ten seconds to finish the process. 10. How to Adjust the Resolution of cmt-hdm 1. Launch Easybuilder pro software. 2. Select cmt-hdm model and select customized from [Project resolution]. Enter the resolution size. The maximum resolution allowed to enter is based on the maximum resolution of the touch screen you have. cmt-hdm supports display resolution up to 1920x1080. Note: In Easybuilder pro v6.02.01 or greater, cmt-hdmi is renamed to cmt-hdm. 3. If you want to adjust the resolution during programming, go to [Home] tab on the toolbar» [System Parameters]» [Model] tab. 4. The resolution setting will be displayed as shown.

Note: When 1920 x 1080 resolution is chosen, the Window Transition Animation and Media Player object won t be accessible. Window Transition Animation (in Direct Window object and Indirect Window object)- Media Player object -

11. cmt-viewer cmt-viewer is a free client application, which can remote access the screen of cmt-hdm located on the LAN (Local Area Network) via Wi-Fi connectivity or Ethernet cable connection. To use it, users need to download and install the cmt-viewer App to mobile devices or PCs. When the cmt-viewer App runs on a device and connects to a cmt-hdm, only data is exchanged between the device and the cmt-hdm instead of graphical desktop sharing. Three client devices can remotely view and control the project of a cmt-hdm simultaneously. Supported Operating System Where to Download Compatibility Android phones or tablets Google Play store V4.1 or greater ios devices App Store V6 or greater Windows PC Weintek USA official website (Stand-alone App. or Easybuilder pro ) Windows 7 or Windows 10 Note: cmt-viewer is installed with Easybuilder pro package on a PC. To find it, launch Utility Manager» Select *cmt Series+ model» *Maintenance+tab» *cmt-viewer+. Typical Application Diagram

cmt-viewer App Interface Some operation options of the cmt-viewer App opened on different operating systems may vary. This document discusses how to operate the cmt-viewer App running on a PC. First, launch cmt-viewer App. Note: 1.In this demonstration, the version 2.6.38 of cmt-viewer App is used. 2.Edit, Auto Play, and Page Indicator icons are only present when Monitor Mode functionality is enabled in the *Settings+ page. Connect Menu- Click the Connect button and search for cmt-hdm HMIs on *Search+ tab. The available cmt-hdm HMIs will be shown as below when existing on the local network. Tap an Add icon on the desired cmt-hdm, and it will bring up a window requiring enter the password.

After that, the corresponding project will be loaded. If you want to go back to Connect menu, click on the Start (Home) button at the upper left corner.

Add the second project to cmt-viewer App to switch and view different projects. The small pictures of the images as shown below are images of the cmt-hdm projects before leaving the projects. On *History+ tab, you can connect the recently accessed projects. If cmt-hdm HMIs are configured to DHCP, the history records may not be usable anymore since the IP addresses are changed. Click clear button to delete history records if needed. The gear buttons nearby each cmt-hdm can open web interface to configure Setup of cmt-hdm.

Settings Menu - [Information] tab: Displays the version of the cmt-viewer App. [General] tab: Provides general settings. Change password- Allows users to change the password of more settings at the bottom left corner. Display datetime bar - Determines if the time bar is shown on the top of cmt-viewer. Adjust cmt Viewer to windows size - Adjusts cmt-viewer to fit the window when users maximize the window of cmt Viewer App. Portrait mode- Allows cmt Viewer to switch to Portrait mode.

[Language] tab: Select a language for cmt-viewer menus. The language selected on the project of the cmt-hdm won t be changed by this setting. To enable Monitor Mode and use Password Protection functionalities, click on more settings icon and log in with the password set on Change password. The default password is 111111. There are more options available on the General tab, and the Password Protection tab is added to the menu. [Monitor mode]- Allows multiple projects displayed on cmt-viewer and shows important real-time data for the projects of each cmt-hdm. [Show Start button] - If disabled, the Home icon on the project will be hidden.

[Password Protection] - Accessing the protected actions will require the password if actions are selected below. Specify a password on [Change password] of this page. Open Project: The action to connect to cmt-hdm and load its project. Close Project: The action to close projects on cmt-viewer. Server Settings: The action to go to web interface of cmt-hdm. Clear History: The action to clear recently accessed projects on the History tab of the Connect menu. If selecting any actions, the Password Protect icon will be present.

In Password Protection mode, protected actions are locked. To access them, click on Password Protect icon and enter the corresponding password. The protected actions are accessible to users with knowledge of assigned password. There is a countdown timer displayed as shown below. When the time runs out, the Password Protection mode will be activated.

12. Monitor Mode The small images of the cmt-hdm project as shown below will be updated automatically, so users will see the latest data without entering each cmt-hdm project. Click on Auto Play button. cmt-viewer will automatically go to the next page. To pause the Auto Play mode, click the Pause button highlighted in red. To leave the Auto Play mode, click the Stop button highlighted in orange.

When clicking on the Device Information button, the names of cmt-hdm HMIs, as well as their IP addresses, will be displayed as below. Tap the Gear (Setup) buttons to go to the web interface of cmt-hdm. Click the Edit button to configure the page layout.

Edit Menu - [Page] - Click the Add button to create a new page or delete the current page with the Delete button. Up to 9 pages can be created in each cmt-viewer. [Move the current page] - Switch to the first page, the previous page, the next page, or the last page. [Layout] - Set up the maximum number of projects in each page. It provides 3x3(9) format and 5x4(20) format. [AutoPlay] - Set up the time interval for Auto Play mode to go to the next page after the given time interval. Note: To show real-time data for the project of a cmt-hdm like below, you must enable Monitor Mode in Easybuilder pro and create a screen for visualization. Here are steps to configure. 4. Launch Easybuilder pro software v6.01.01 or greater. 5. Create a project of cmt-hdm. 6. Go to [Home] tab» [System Parameters]. 7. In [System Parameters], click on [General] tab. 8. Enable Monitor Mode checkbox. This option is turned off by default.

9. Close [System Parameters] settings. Open the window no.3, titled Monitor Mode. 10. Place Text object, Bit Lamp object, Word Lamp object, Numeric Display object, ASCII Display object, Bar Graph object or Alarm Display object to show up-to-date data on this screen, so you can see the data shown and updated on the cmt-viewer App. 8. Download this project to a cmt-hdm.

13. cmt-viewer Limitations Feature Limitation Some features do not work on a cmt Viewer client (PC, ios, Android, cmt-iv5), even if they work on the local cmt HMI. Please take this into consideration when programming projects. Features (Objects) that do not work remotely on cmt Viewer App are listed below. File Browser Media Player Video In: USB Camera Video In: IP Camera Video In: Video Input (analog) Picture View PDF Reader VNC Viewer Selected features of Function Key: Screen hardcopy, Import user data/user [USB Security Key] Selected features of PLC Control i. Screen hardcopy: Files are saved in the external drive on HMI ii. Backlight: Backlight control of HMI screen Selected features of Operation Log i. Operation Log printing: Logs are saved in the external drive on HMI Above objects won t be displayed on a cmt Viewer App, but can be accessed via a VNC client.

Maximum Connect Count Three cmt-viewer clients are allowed to remotely view and control the project of a cmt-hdm simultaneously. When the fourth cmt-viewer client connects to the cmt-hdm, the warning message as shown below will pop up and reject the connection. The maximum capacity can be adjusted in Easybuilder pro software. Here are the steps. 1. Launch Easybuilder pro v6.01.01 or greater. 2. Go to *Home+ tab» *System Parameters+. 3. Click on *Remote+ tab. 4. Within cmt-viewer, set up a number of cmt-viewer max connections. Up to 10 cmt-viewer clients are allowed to connect to one cmt-hdm. Warning: Allowing a number of cmt-viewer connections up to 4 or over will affect HMI performance. Please take this into consideration when programming projects.

14. cmt Objects Introduction Basic objects (Features): Bit type object [Bit Lamp] displays the state of a designated bit. If the bit state is OFF, the State 0 shape will be displayed. If the bit state is ON, the State 1 shape will be displayed. [Set Bit] triggers a designated bit address to change the state to ON or OFF when the object is touched. [Toggle Switch] is a combination of Bit Lamp object and Set Bit object. Word type object [Word Lamp] displays the state with a shape according to the value of a designated word register. [Set Word] changes the value in a designated word register when the object is touched. [Multi-state Switch] is a combination of Word Lamp object and Set Word object. [Combo button] allows operators to execute multiple commands with one object, including bit and word register. [Numeric] can be used to input or display the value of a designated word register. [Ascii] can be used to input or display ASCII or UNICODE characters held in designated word registers. [Bar Graph] displays the value of a designated word register with a bar graph. [Slider] will change the value of a designated word register when operators move the tick of the Slider object.

[Meter Display] displays the value of a designated word register with a meter. [Moving Shape] is an object defined by the states and tracks of a program developer. The state and the location depend on consecutive word registers. Other basic objects - [Option List] displays a list of items that can be viewed and selected. Once an item is selected, the specified value will be written to a designated word register. [Scheduler] turns bit ON/OFF, or writes values to word registers at designated start times. It works on a weekly basis. [Timer] turns bit ON when time reaches set point. [PLC Control] executes task when it is triggered.

[Pie Chart] draws a pie chart that divides a circle into several slices to illustrate proportion, according to the value of a designated word register. [Function Key] provides several functions, such as switching to another page, opening a pop-up window, keypad design, Macro execution and so on. Multi language supported- Up to 8 languages can be added to the project of the cmt Series HMI. Use the language menu (System register LW-9134) to select a desired language for the project. Enhanced Security (Objects protected) - Up to 11 users can be set in an HMI program, and one Admin user has all privileges and can operate all object classes. User passwords must be alphanumeric and each user can have up to 12 classes (A to L). Recipe Database - Allows operators to view, add, update, delete, and use recipes.

Direct Window (Controlled by bit) - Operators can open or close a pop-up window by a designated bit at the predefined location. Indirect Window (Controlled by word register) - Operators can open or close a pop-up window by a designated word register at the predefined location. The background transparency of Direct Window and Indirect Window is adjustable in the HMI program.

Application This demo program demonstrates the application for a cheese factory. There are four main steps in the production process, pasteurization, coagulation, mixing, and pressing. The first page is an overview page that shows important data, alarms, and real-time trending charts. Overview page [Event Display] displays alarm messages which are predefined in Event Log object (Event dector) and have met a trigger condition. [Trend Display] displays data in a chart. The data must be predefined in Data Sampling object (Data logger). [History Data Display] displays data in a table. The data must be predefined in Data Sampling object (Data logger). Scroll down and scroll horizontally to view more data shown on the two tables and the chart. Pasteurization page [Flow block] displays the flow speed in a pipe or the speed in a transportation line.

Coagulation page Animations are configured by Bit Lamp objects and Word Lamp objects. Bit Lamp Word Lamp Mixing page Animations are configured by Word Lamp objects. Word Lamp Pressing page Animations are configured by Bit Lamp objects and a Word Lamp object. Word Lamp Bit Lamp

Packaging page Animations are configured by Bit Lamp objects. Bit Lamp

15. cmt-hdm Gestures Operation Tap: This is the most common gesture. Briefly touch HMI screen with fingertip. Drag: Move fingertip over HMI screen without losing contact. Press: Touch HMI screen for extended period of time. Pinch: Touch HMI screen with two fingers and bring them closer together. Spread: Touch HMI screen with two fingers and move them apart. Gestures may vary when operating project on different touch screens. On resistive touch screen: Gestures Tap Drag (Scroll horizontally, scroll up, and scroll down on the object to view more data) Press Supported Objects (Features) All Input objects Data log: Trend Display, History Data Display Event log: Event Display, Event Bar Chart(Gantt) Operation log: Operation Log View Recipe: Recipe View SQL: SQL Query Result Viewer Others: Option-List, Data Block Display This gesture can be configured on the property of the object in HMI program if needed. On cmt Viewer APP or capacitive touch screen: Gestures Supported Objects (Features) Tap All Input objects *1 Drag Data log: Trend Display, History Data Display (Scroll horizontally, scroll up, and Event log: Event Display, Event Bar Chart(Gantt) scroll down on the object to view Operation log: Operation Log View more data) Recipe: Recipe View SQL: SQL Query Result Viewer Others: Option-List, Data Block Display Press This gesture can be configured on the property of the object in HMI program if needed. Pinch Data log: Trend Display Spread Data log: Trend Display *1 Input objects refers to objects that are allowed operators to open a window as well as pop-up window, press a button to turn bit ON/OFF, or enter a value to a word register. Note: 1. cmt-hdm doesn t support page switching by drag and flick gestures. 2. For more information about Press, refer to the section 10.5 Object Security Settings in Easybuilder pro user manual and see Min. press time (Sec).

Reference Link: Weintek Labs website: http://www.weintek.com Founded in 1996, WEINTEK LABS is a global-leading HMI manufacturer and is dedicated to the development, design, and manufacturing of practical HMI solutions. WEINTEK LAB s mission is to provide quality, customizable HMI-solutions that meet the needs of all industrial automation requirements while maintaining customer satisfaction by providing on-demand customer service. WEINTEK LABS brought their innovative technology to the United States in 2016, WEINTEK USA, INC., to provide quality and expedient solutions to the North American industrial market. 6219 NE 181s Street STE 120 Kenmore, WA 98028 425-488-1100