BNI IOL E012. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

Similar documents
BNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide

BNI IOL Z046. IO-Link 1.1 Sensor hub with extension port User's Guide

BNI IOL Z019. IO-Link 1.1 sensor hub With extension port User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL Z012 BNI IOL-302-S01-Z012 BNI IOL Z042

BNI IOL A027 BNI IOL A027

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K006 BNI IOL K006-C01 BNI IOL-302-S01-K006 BNI IOL-302-S01-K006-C01. IO-Link 1.1 Sensor-Hub / Actuator-Hub User s Guide

BNI IOL K006 BNI IOL-106-S01-K006 BNI IOL-106-S01-K006-C01. User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL-104-S01-Z012-C02

BNI IOL K006. IO Link Sensorhub digital User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z036 BNI IOL Z BNI IOL Z037 BNI IOL Z Smart Light User s Guide

BNI IOL Z012. User s Guide

BNI USB A501. User s Guide

BNI IOL Z012. User s Guide

BNI IOL Z036 BNI IOL Z036

BNI IOL Z036 BNI IOL Z037. Smart Light User s Guide

BNI IOL K023 BNI IOL K023. User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI IOL-75x-Vxx-K007 Valve Plug Short Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI PBS Z001. IP67 module, Profibus IO-Link Master Short Guide

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

BNI EIP E002. EtherNet/IP IP69 modules User's Guide

BIC 1B0-ITA50-Q40KFU-SM4A4A BIC 1B0-IT005-Q40KFU-SM4A4A BIC 2B0-ITA50-Q40KFU-SM4A5A. User s Guide

BNI USB A501. USB IO-Link Master User's Guide. english

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI EIP Z016 IP67 Modules, 16 In-/Outputs User s Guide

BNI EIP Z040. IP67 Module 4 IO-Link Class A and 8 in- and outputs 4 IO-Link Class B and 4 inputs User's Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI DNT Z001 DeviceNet IO-Link Master User s Guide

BIS L x-07-S4

BNI PNT Z015 BNI006C. IP67 Module User s Guide

BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 modules User's Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005. User s Guide

BNI CIE Z015 BNI CIE Z015 BNI CIE Z015 BNI CIE Z015. CC-Link IE Field Standard I/O Modules User's Guide

BNI CIE Z015 BNI CIE Z015. CC-Link IE Field IO-Link Master User's Guide

BNI PNT Z031 BNI PNT Z IP67 Module User s Guide

BNI EIP Z015. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

BNI EIP R015 BNI EIP R015. EtherNet/IP IP67 modules User's Guide

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI CCL Z001. CC-Link IO-Link Master User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI EIP Z015-C06. IP67 Modules 8 IO-Link/In-/Outputs, 8 In-/Outputs User s Guide

Balluff Network Interface / CC-Link BNI-CCL Z001 BNI CCL Z001. Extended User Manual. 1

BNI CCL Z001. CC-Link IO-Link Master User s Guide

BNI EIP Z015-C06. EtherNet/IP IP67 modules User's Guide

BNI EIP Z015 IP67 Modules 16 Inputs User s Guide

SCHMIDT Sensor interface PROFIBUS Instructions for use

GFK-2415A March Type of sensor connection

User's Manual. english

BIS V-6102 PROFIBUS. Technical Description, User s Guide. english 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

BIS M _ 0 _ -07-S4 BIS M _ 0 _ -07-S4

BTL6-A_10-M -A1-S115. Data Sheet. english

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Profibus IO Modules User's Guide

BIS V-6102 Profibus. Technical Description, User's Guide. English 42,7 61,9 5,3 168,3 +6,0 157,6 +6,0 36,4 2,5 48,2

BNI EIP Z015 BNI EIP Z015 BNI EIP Z015. EtherNet/IP IP67 Modules User s Guide

BTL6-V1 _ E-M -A1-S115 User's Guide

2-Axis Counter BDD 622

BIS L x-07-S4

Manual LioN-P - IO-Link Device - I/O Hub

VersaMax IP I/O Module

Operating instructions AC010S Compact AS-i E-STOP safety module

Pressure Transmitters with IO-Link BSP-Bxxx-xx004-xxxS1A-xx, BSP-Vxxx-xx004-xxxS1A-xx

BNI PNT Z015 BNI PNT Z015. IP67 Module User s Guide

BNI PNT Z063. IP67 Module User's Guide

BTL6-V11V-M -A1-S115 User's Guide

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions Memory plug E /02 11/2011

BIS M xx-ST4 PROFINET

Profibus I/O Modules BNI PBS Z001 BNI PBS Z001

BNI PNT Z033. IP67 Module User s Guide

BIS V-6108 PROFINET. Technical Description, User s Guide. english

BIS M _ -07-S4 BIS M _ -07-S4

Single-Axis Counter BDD 611

VersaMax IP Input Module

AXL E IOL AO1 U M12 R

SK TU4-IOE-M12-C Part Number

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

Operating instructions. Switching amplifier DN0210 DN / / 2015

BIS M x-ST4 EtherNet/IP

Operating instructions ClassicLine module AC / / 2012

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Hardware Manual RM CANview Gateway

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

READ/WRITE MODULES (RWM) RLS

Transcription:

BNI IOL322E12 IOLink 1.1 sensor/actuator hub with extension port User's Guide

Balluff Network Interface / IOLink BNI IOL322E12 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical Conventions 4 Enumerations 4 Actions 4 Syntax 4 Crossreferences 4 1.3. Symbols 4 1.4. Abbreviations 4 1.5. Deviating views 4 2 Safety 5 2.1. Intended use 5 2.2. Installation and Startup 5 2.3. General Safety Notes 5 2.4. Resistance to Aggressive Substances 5 3 First Steps 6 3.1. Connection Overview 6 3.2. Mechanical Connection 7 3.3. Electrical Connection 7 Function ground 7 IOLink connection 7 Connecting the sensor hub 8 Module variants 8 Sensor interface 8 Extension port 55hex 8 4 General Configuration 9 Extension port configuration 55hex 9 Setting the serial number 54hex 9 5 Configuration: "Extension Off" 1 5.1. IOLink data 1 5.2. Process Data/Input Data 1 5.3. Process Data/ Output Data 1 5.4. Parameter Data / Demand Data 11 Inversion of the inputs 4hex 12 Configuration of inputs/outputs 41hex 12 Safe state of Outputs 42hex 12 Safe state of the outputs on Pin 4 42hex 13 Safe state of the outputs on Pin 2 43hex 13 Voltage monitoring 44hex 13 Monitoring the outputs 45hex 14 Monitoring the outputs 46hex 14 Setting the serial number 54hex 14 Configuration of the extension port 55hex 14 6 Configuration: Extended with BNI IOL322E12 15 6.1. IOLink data 15 6.2. Process Data/Input Data 15 6.3. Process Data/ Output Data 16 6.4. Parameter Data / Demand Data 17 Parameter Data / Demand Data 17 Inversion of the inputs 4hex 18 Configuration of inputs/outputs 41hex 19 Safe state of Outputs 42hex 19 Safe state of the outputs on Pin 4 42hex 2 Safe state of the outputs on Pin 2 43hex 21 Voltage monitoring 44hex 22 www.balluff.com 2

Setting the serial number 54hex 22 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves 23 7.1. IOLink data 23 7.2. Process Data/Input Data 23 7.3. Process Data/ Output Data 24 7.4. Parameter Data / Demand Data 25 Inversion of the inputs 4hex 26 Configuration of inputs/outputs 41hex 26 Safe state of Outputs 42hex 27 Safe state of the outputs on Pin 4 42hex 27 Safe state of the outputs on Pin 2 43hex 28 Voltage monitoring 44hex 29 Monitoring the outputs 45hex 3 Setting the serial number 54hex 3 7.5. Errors 31 7.6. Events 31 8 IOLink functions 32 8.1. IOLink Version 1. / 1.1 32 8.2. Data Storage 32 8.3. Block Configuration 32 8.4. Resetting to Factory Settings 32 9 Technical Data 33 9.1. Dimensions 33 9.2. Mechanical Data 33 9.3. Electrical Data 33 9.4. Operating conditions 33 1 Function indicators 34 1.1. Function indicators 34 LED indicator module status 34 Digital LED indicators for inputs/outputs 35 Extension port 35 11 Appendix 36 11.1. Type code 36 11.2. Ordering information 36 www.balluff.com 3

Balluff Network Interface / IOLink BNI IOL322E12 1 General 1.1. Structure of the Manual 1.2. Typographical Conventions Enumerations Actions Syntax Crossreferences The manual is organized so that the sections build on one another. Chapter 2: Basic Safety Information... The following typographical conventions are used in this manual. Enumerations are shown as a list with an endash. Entry 1, Entry 2. Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow. Action instruction 1. Action result. Action instruction 2. Numbers: Decimal numerals are shown without an additional indicator (e.g. 123), Hexadecimal numerals are shown with the additional indicator hex (e.g. hex). Crossreferences indicate where additional information on the topic can be found. 1.3. Symbols Attention! This symbol indicates a security notice which must be observed. Note This symbol indicates general notes. 1.4. Abbreviations BNI DPP I/O port EMC FE IOL LSB MSB SPDU US UA HF noise Balluff Network Interface Direct Parameter Page Digital input/output port Electromagnetic compatibility Function ground IOLink Least Significant Bit Most Significant Bit Service Protocol Data Unit Sensor supply undervoltage Actuator supply undervoltage Highfrequency noise 1.5. Deviating views Product views and illustrations in this manual may differ from the actual product. They are intended only as illustrative material. www.balluff.com 4

2 Safety 2.1. Intended use The BNI IOL acts as a decentralized input/output sensor module, which is connected to a higherlevel IOLink master module through an IOLink interface. 2.2. Installation and Startup 2.3. General Safety Notes 2.4. Resistance to Aggressive Substances Attention! Installation and startup must only be carried out by trained technical personnel. Qualified personnel are people who are familiar with installation and operation of the product and have the necessary qualifications for these tasks. Any damage resulting from unauthorized tampering or improper use voids the manufacturer's guarantee and warranty. The operator must ensure that appropriate safety and accident prevention regulations are observed. Commissioning and inspection Before commissioning, carefully read the user's guide. The system must not be used in applications in which the safety of persons is dependent upon proper functioning of the device. Authorized personnel Installation and startup must only be carried out by trained technical personnel. Intended use Warranty and liability claims against the manufacturer are rendered void by: Unauthorized tampering Improper use Use, installation or handling contrary to the instructions provided in this user's guide Obligations of the operating company The device is a piece of equipment in accordance with EMC Class A. This device can produce RF noise. The operator must take appropriate precautionary measures. The device may only be used with an approved power supply. Use only approved cables. Malfunctions In the event of defects and device malfunctions that cannot be rectified, the device must be taken out of operation and protected against unauthorized use. Intended use is ensured only when the housing is fully installed. Attention! The BNI modules always have good chemical and oil resistance. When used in aggressive media (such as chemicals, oils, lubricants and coolants, each in a high concentration (i.e. too little water content)), the material must first be checked for resistance in the particular application. No defect claims may be asserted in the event of a failure or damage to the BNI modules caused by such aggressive media. Note In the interests of product improvement, Balluff GmbH reserves the right to change the technical data of the product and the content of this manual at any time without notice. Attention! Before maintenance, disconnect the device from the power supply. www.balluff.com 5

Balluff Network Interface / IOLink BNI IOL322E12 3 First Steps 3.1. Connection Overview 1 13 12 2 11 3 1 4 9 5 8 6 7 1 Figure 31: Connection overview BNI IOL322E12 1 Mounting hole/ground 2 Status LED: communication 3 Port 1 4 Port 3 5 Port 5 6 Port 7, extension port 7 Pin/Port LED: signal status 8 Port 6 9 Port 4 1 Port 2 11 Port 12 Status LED: supply module 13 IOLink Interface www.balluff.com 6

3 First Steps 3.2. Mechanical Connection 3.3. Electrical Connection The BNI IOL modules are attached using 2 M6 screws and 2 washers. The modules do not require a separate supply voltage connection. Supply voltage is provided via the IOLink interface and the higherlevel IOLink master module. Function ground Fig. 33: Ground connection using mounting screw Note The function ground connection from the housing to the machine must have lowimpedance and is made using the mounting screw. IOLink connection The IOLink connection is established via an M12 connector (Acoded, male). IOLink (M12, Acoded, male) Pin Requirement 1 Supply voltage for controller/sensors US, +24V 2 Supply voltage for actuators UA, +24V 3 GND, reference potential 4 C/Q, IOLink data transmission channel www.balluff.com 7

Balluff Network Interface / IOLink BNI IOL322E12 3 First Steps Connecting the sensor hub Connect ground conductor to the functional ground connection, if available. Connect the incoming IOLink cable to the sensor hub. Note A standardized sensor cable is used to connect to the higherlevel to the IOLink master module. Maximum length of 2 m. Module variants Sensor hub variants Digital port BNI IOL322E12 16 inputs/outputs Sensor interface Digital input port (M12, Acoded, female) Pin Requirement 1 +24 V 2 Input / output 2 3 V, GND 4 Input / output 1 5 Function GND Note For the digital inputs, the input guideline specified in EN 611312, Type 3 applies Note Unused input port sockets must be fitted with blind caps to ensure the IP69 degree of protection. Extension port 55hex Extension port (M12, Acoded, female) The port acts like a sensor/actuator interface if the extension function is disabled. Pin Requirement 1 +24 V 2 Extension port for actuator power supply 3 V, GND 4 Communication 5 FE Note A standardized sensor cable is used to connect to the device/sensor to be expanded. Maximum length of 2 m. www.balluff.com 8

4 General Configuration The modules gives you the ability to use the No. 7 slot in various ways. By default, it is used as a digital input slot, where both pin 2 and pin 4 can be used as a digital input. This slot can be used as an extension port by making a corresponding entry in the parameter with an index of 55hex. This makes it possible to operate one of the following modules using the No. 7 slot. BNI IOL322E12 BNI IOL751V8K7 BNI IOL751V1K7 BNI IOL751V13K7 Extension port configuration 55hex Configuration 55hex value BNI IOL322E12 BNI IOL322E12 with BNI IOL322E12 1 BNI IOL322E12 with BNI IOL751V8K7 2 BNI IOL322E12 with BNI IOL751V1K7 3 BNI IOL322E12 with BNI IOL751V13K7 4 Note The "Factory reset" command does not affect the configuration of the extension port in any way. Note The process data length depends on the configuration. The extension port can be configured using parameter x55 (table). If data storage or validation is used, validation (identical) must be used for configuring. Depending on the system, the Device ID has to be entered (parameter data table) or the Device ID is read out from the IODD. Setting the serial number 54hex The serial number has a default value of 16xhex. In order to use the "Identity" master validation mode, a serial number can be set using this parameter. This prevents a device from connecting to the wrong master port. www.balluff.com 9

Output Port 7 Pin 4 Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3 Pin 4 Output Port 2 Pin 4 Output Port 1 Pin 4 Output Port Pin 4 Output Port 7 Pin 2 Output Port 6 Pin 2 Output Port 5 Pin 2 Output Port 4 Pin 2 Output Port 3 Pin 2 Output Port 2 Pin 2 Output Port 1 Pin 2 Output Port Pin 2 Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin 2 Input Port Pin 2 Balluff Network Interface / IOLink BNI IOL322E12 5 Configuration: "Extension Off" 5.1. IOLink data BNI IOL322E12 extension off Transmission rate COM2 (38.4 kbaud) Minimum cycle time 4. ms Process data length 2 byte input, 2 byte output 5.2. Process Data/Input Data 5.3. Process Data/ Output Data www.balluff.com 1

Parameter data Identification data Read only 5 Configuration: "Extension Off" 5.4. Parameter Data / Demand Data DPP SPDU Parameter Data Subindex width 7hex 7 8hex 8 9hex 9 Ahex 1 Bhex 11 1hex 16 11hex 17 12hex 18 13hex 19 14hex 2 15hex 21 16hex 22 Vendor ID 2 bytes Access rights Default value 378hex Device ID 3 bytes x5 D 8 Vendor Name BALLUFF Vendor text www.balluff.com Product Name BNI IOL322E12 Product ID BNIAR Product text M12 sensor/actuator hub Serial number 16 bytes hex Hardware revision 17hex 23 Firmware revision 18hex 24 Applicationspecific tag 32 bytes hex DPP SPDU Parameter Data width Access rights Default Subindex Value 4hex 64 41hex 65 42hex 66 43hex 67 44hex 68 45hex 69 46hex 7 116 116 116 18 116 116 116 Inversion of the inputs 2 bytes Read/write hex Config. inputs/outputs 2 bytes Read/write hex Safe state on Pin 4 4 bytes Read/write hex Safe state on Pin 2 2 bytes Read/write hex Voltage monitoring 2 bytes Read Output monitoring 2 bytes Read Actuator warning 2 bytes Read 54hex 84 55hex 85 Serial number 16 bytes Read/write 16xhex Extension port 1 byte Read/write hex www.balluff.com 11

Direction Port 7 Pin 4 Direction Port 6 Pin 4 Direction Port 5 Pin 4 Direction Port 4 Pin 4 Direction Port 3 Pin 4 Direction Port 2 Pin 4 Direction Port 1 Pin 4 Direction Port Pin 4 Direction Port 15 Pin 4 Direction Port 14 Pin 4 Direction Port 13 Pin 4 Direction Port 12 Pin 4 Direction Port 11 Pin 4 Direction Port 1 Pin 4 Direction Port 9 Pin 4 Direction Port 8 Pin 4 Inversion of Port 7 Pin 4 Inversion of Port 6 Pin 4 Inversion of Port 5 Pin 4 Inversion of Port 4 Pin 4 Inversion of Port 3 Pin 4 Inversion of Port 2 Pin 4 Inversion of Port 1 Pin 4 Inversion of Port Pin 4 Inversion of Port 7 Pin 2 Inversion of Port 6 Pin 2 Inversion of Port 5 Pin 2 Inversion of Port 4 Pin 2 Inversion of Port 3 Pin 2 Inversion of Port 2 Pin 2 Inversion of Port 1 Pin 2 Inversion of Port Pin 2 Balluff Network Interface / IOLink BNI IOL322E12 5 Configuration: "Extension Off" Inversion of the inputs 4hex 8 7 6 5 4 3 2 1 16 15 14 13 12 11 1 9 Inversion of port (x): Normal 1 Inverted. Configuration of inputs/outputs 41hex Subindex 8 7 6 5 4 3 2 1 16 15 14 13 12 11 1 9 Direction of port (x): Input 1 Output Safe state of Outputs 42hex The safe state parameter makes it possible to configure the outputs in case of a fault. If no IO Link communication is possible or the "valid flag" of the output process data has not been set by the master, then each output adopts the configured status. The following statuses can be configured for each pin. www.balluff.com 12

Shortcircuit Port 7 Pin 1 Shortcircuit Port 6 Pin 1 Shortcircuit Port 5 Pin 1 Shortcircuit Port 4 Pin 1 Shortcircuit Port 3 Pin 1 Shortcircuit Port 2 Pin 1 Shortcircuit Port 1 Pin 1 Shortcircuit Port Pin 1 Output off (UA too low) Undervoltage UA Undervoltage US1 Safe state Port 3 Pin 2 Safe state Port 2 Pin 2 Safe state Port 1 Pin 2 Safe state Port Pin 2 Safe state Port 7 Pin 2 Safe state Port 6 Pin 2 Safe state Port 5 Pin 2 Safe state Port 4 Pin 2 Safe state Port 3 Pin 4 Safe state Port 2 Pin 4 Safe state Port 1 Pin 4 Safe state Port Pin 4 Safe state Port 7 Pin 4 Safe state Port 6 Pin 4 Safe state Port 5 Pin 4 Safe state Port 4 Pin 4 5 Configuration: "Extension Off" Safe state of the outputs on Pin 4 42hex 4 3 2 1 8 7 6 5 Safe state of the outputs on Pin 2 43hex 4 3 2 1 8 7 6 5 Value bin dec Output state Output is V 1 1 Output is 24V 1 2 Current status is maintained 11 3 Not defined Voltage monitoring 44hex 8 7 6 5 4 3 2 1 12 11 9 www.balluff.com 13

Warning Port 7 Pin 4 Warning Port 6 Pin 4 Warning Port 5 Pin 4 Warning Port 4 Pin 4 Warning Port 3 Pin 4 Warning Port 2 Pin 4 Warning Port 1 Pin 4 Warning Port Pin 4 Warning Port 7 Pin 2 Warning Port 6 Pin 2 Warning Port 5 Pin 2 Warning Port 4 Pin 2 Warning Port 3 Pin 2 Warning Port 2 Pin 2 Warning Port 1 Pin 2 Warning Port Pin 2 Shortcircuit Port 7 Pin 4 Shortcircuit Port 6 Pin 4 Shortcircuit Port 5 Pin 4 Shortcircuit Port 4 Pin 4 Shortcircuit Port 3 Pin 4 Shortcircuit Port 2 Pin 4 Shortcircuit Port 1 Pin 4 Shortcircuit Port Pin 4 Shortcircuit Port 7 Pin 2 Shortcircuit Port 6 Pin 2 Shortcircuit Port 5 Pin 2 Shortcircuit Port 4 Pin 2 Shortcircuit Port 3 Pin 2 Shortcircuit Port 2 Pin 2 Shortcircuit Port 1 Pin 2 Shortcircuit Port Pin 2 Balluff Network Interface / IOLink BNI IOL322E12 5 Configuration: "Extension Off" Monitoring the outputs 45hex 8 7 6 5 4 3 2 1 16 15 14 13 12 11 1 9 Monitoring the outputs 46hex 8 7 6 5 4 3 2 1 16 15 14 13 12 11 1 9 Setting the serial number 54hex Configuration of the extension port 55hex The serial number has a default value of 16xhex. In order to use the "Identity" master validation mode, a serial number can be set using this parameter. This prevents a device from connecting to the wrong master port. Configuration 55hex value BNI IOL322E12 BNI IOL322E12 with BNI IOL322E12 1 BNI IOL322E12 with BNI IOL751V8K7 2 BNI IOL322E12 with BNI IOL751V1K7 3 BNI IOL322E12 with BNI IOL751V13K7 4 Note! The "Factory reset" command does not affect the configuration of the extension port in any way. www.balluff.com 14

Input Port 7 Pin 4 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin 2 Input Port Pin 2 Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port Pin 4 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin 2 Input Port Pin 2 6 Configuration: Extended with BNI IOL322E12 6.1. IOLink data BNI IOL322E12 extended with BNI IOL322E12 Transmission rate COM2 (38.4 kbaud) Minimum cycle time 5. ms Process data length 4 bytes input, 4 bytes output 6.2. Process Data/Input Data Byte 2 3 Extension port www.balluff.com 15

Output Port 7 Pin 4 Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3 Pin 4 Output Port 2 Pin 4 Output Port 1 Pin 4 Output Port Pin 4 Output Port 7 Pin 2 Output Port 6 Pin 2 Output Port 5 Pin 2 Output Port 4 Pin 2 Output Port 3 Pin 2 Output Port 2 Pin 2 Output Port 1 Pin 2 Output Port Pin 2 Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3 Pin 4 Output Port 2 Pin 4 Output Port 1 Pin 4 Output Port Pin 4 Output Port 6 Pin 2 Output Port 5 Pin 2 Output Port 4 Pin 2 Output Port 3 Pin 2 Output Port 2 Pin 2 Output Port 1 Pin 2 Output Port Pin 2 Balluff Network Interface / IOLink BNI IOL322E12 6 Configuration: Extended with BNI IOL322E12 6.3. Process Data/ Output Data Byte 2 3 Extension port www.balluff.com 16

Parameter data Identification data Read only 6 Configuration: Extended with BNI IOL322E12 6.4. Parameter Data / Demand Data DPP SPDU Parameter Data Subindex width 7hex 7 8hex 8 9hex 9 Ahe x 1 Bhex 11 1hex 16 11hex 17 12hex 18 Vendor ID 2 bytes Access rights Default value 378hex Device ID 3 bytes x5 D 81 Vendor Name BALLUFF Vendor text www.balluff.com Product Name BNI IOL322E12 with BNI IOL322E12 13hex 19 14hex 2 15hex 21 16hex 22 Product ID BNIAR with BNIAR Product text Serial number Hardware revision 16 bytes Sensor hub M12 extended with sensor hub M12 hex 17hex 23 Firmware revision 18hex 24 Applicationspecific tag 32 bytes hex Parameter Data / Demand Data DPP SPDU Parameter Data width Access rights Default Subindex Value 4hex 64 132 Inversion of the inputs 4 bytes Read/write hex 41hex 65 116 Config. inputs/outputs 2 bytes Read/write hex 42hex 66 116 Safe state on Pin 4 4 bytes Read/write hex 43hex 67 18 Safe state on Pin 2 2 bytes Read/write hex 44hex 68 132 Voltage monitoring 4 bytes Read 45hex 69 116 Output monitoring 2 bytes Read 46hex 7 116 Actuator warning 2 bytes Read 54hex 84 55hex 85 Serial number 16 bytes Read/write 16xhex Extension port 1 byte Read/write 1hex www.balluff.com 17

Inversion of Port 7 Pin 4 Inversion of Port 6 Pin 4 Inversion of Port 5 Pin 4 Inversion of Port 4 Pin 4 Inversion of Port 3 Pin 4 Inversion of Port 2 Pin 4 Inversion of Port 1 Pin 4 Inversion of Port Pin 4 Inversion of Port 7 Pin 2 Inversion of Port 6 Pin 2 Inversion of Port 5 Pin 2 Inversion of Port 4 Pin 2 Inversion of Port 3 Pin 2 Inversion of Port 2 Pin 2 Inversion of Port 1 Pin 2 Inversion of Port Pin 2 Inversion of Port 6 Pin 4 Inversion of Port 5 Pin 4 Inversion of Port 4 Pin 4 Inversion of Port 3 Pin 4 Inversion of Port 2 Pin 4 Inversion of Port 1 Pin 4 Inversion of Port Pin 4 Inversion of Port 6 Pin 2 Inversion of Port 5 Pin 2 Inversion of Port 4 Pin 2 Inversion of Port 3 Pin 2 Inversion of Port 2 Pin 2 Inversion of Port 1 Pin 2 Inversion of Port Pin 2 Balluff Network Interface / IOLink BNI IOL322E12 6 Configuration: Extended with BNI IOL322E12 Inversion of the inputs 4hex 8 7 6 5 4 3 2 1 16 15 14 13 12 11 1 9 Byte 2 3 24 23 22 21 2 19 18 17 32 31 3 29 28 27 26 25 Extension port Inversion of port (x): Normal 1 Inverted www.balluff.com 18

Direction Port 7 Pin 4 Direction Port 6 Pin 4 Direction Port 5 Pin 4 Direction Port 4 Pin 4 Direction Port 3 Pin 4 Direction Port 2 Pin 4 Direction Port 1 Pin 4 Direction Port Pin 4 Direction Port 7 Pin 2 Direction Port 6 Pin 2 Direction Port 5 Pin 2 Direction Port 4 Pin 2 Direction Port 3 Pin 2 Direction Port 2 Pin 2 Direction Port 1 Pin 2 Direction Port Pin 2 Direction Port 6 Pin 4 Direction Port 5 Pin 4 Direction Port 4 Pin 4 Direction Port 3 Pin 4 Direction Port 2 Pin 4 Direction Port 1 Pin 4 Direction Port Pin 4 Direction Port 6 Pin 2 Direction Port 5 Pin 2 Direction Port 4 Pin 2 Direction Port 3 Pin 2 Direction Port 2 Pin 2 Direction Port 1 Pin 2 Direction Port Pin 2 6 Configuration: Extended with BNI IOL322E12 Configuration of inputs/outputs 41hex 7 6 5 4 3 2 1 15 14 13 12 11 1 9 Byte 2 3 24 23 22 21 2 19 18 17 32 31 3 29 28 27 26 25 Extension port Direction of port (x): Input 1 Output Safe state of Outputs 42hex The safe state parameter makes it possible to configure the outputs in case of a fault. If no IOLink communication is possible or the "valid flag" of the output process data has not been set by the master, then each output adopts the configured status. The following statuses can be configured for each pin. www.balluff.com 19

Safe state Port 3 Pin 4 Safe state Port 2 Pin 4 Safe state Port 1 Pin 4 Safe state Port Pin 4 Safe state Port 7 Pin 4 Safe state Port 6 Pin 4 Safe state Port 5 Pin 4 Safe state Port 4 Pin 4 Safe state Port 3 Pin 4 Safe state Port 2 Pin 4 Safe state Port 1 Pin 4 Safe state Port Pin 4 Safe state Port 6 Pin 4 Safe state Port 5 Pin 4 Safe state Port 4 Pin 4 Balluff Network Interface / IOLink BNI IOL322E12 6 Configuration: Extended with BNI IOL322E12 Safe state of the outputs on Pin 4 42hex 4 3 2 1 7 6 5 Byte 2 3 12 11 1 9 16 15 14 13 Extension port www.balluff.com 2

Safe state Port 3 Pin 2 Safe state Port 2 Pin 2 Safe state Port 1 Pin 2 Safe state Port Pin 2 Safe state Port 7 Pin 2 Safe state Port 6 Pin 2 Safe state Port 5 Pin 2 Safe state Port 4 Pin 2 Safe state Port 3 Pin 2 Safe state Port 2 Pin 2 Safe state Port 1 Pin 2 Safe state Port Pin 2 Safe state Port 7 Pin 2 Safe state Port 6 Pin 2 Safe state Port 5 Pin 2 Safe state Port 4 Pin 2 6 Configuration: Extended with BNI IOL322E12 Safe state of the outputs on Pin 2 43hex 4 3 2 1 8 7 6 5 Byte 2 3 12 11 1 9 16 15 14 13 Extension port Value bin dec Output state Output is V 1 1 Output is 24V 1 2 Current status is maintained 11 3 Not permitted www.balluff.com 21

Shortcircuit Port 7 Pin 1 Shortcircuit Port 6 Pin 1 Shortcircuit Port 5 Pin 1 Shortcircuit Port 4 Pin 1 Shortcircuit Port 3 Pin 1 Shortcircuit Port 2 Pin 1 Shortcircuit Port 1 Pin 1 Shortcircuit Port Pin 1 Output off (UA too low) Undervoltage UA Undervoltage US1 Shortcircuit Port 7 Pin 1 Shortcircuit Port 6 Pin 1 Shortcircuit Port 5 Pin 1 Shortcircuit Port 4 Pin 1 Shortcircuit Port 3 Pin 1 Shortcircuit Port 2 Pin 1 Shortcircuit Port 1 Pin 1 Shortcircuit Port Pin 1 Output off (UA too low) Undervoltage UA Undervoltage US1 Balluff Network Interface / IOLink BNI IOL322E12 6 Configuration: Extended with BNI IOL322E12 Voltage monitoring 44hex 8 7 6 5 4 3 2 1 12 11 9 Byte 2 3 24 23 22 21 2 19 18 17 32 31 3 29 28 27 25 Extension port Setting the serial number 54hex The serial number has a default value of 16xhex. In order to use the "Identity" master validation mode, a serial number can be set using this parameter. This prevents a device from connecting to the wrong master port. www.balluff.com 22

Input Port 6 Pin 4 Input Port 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port Pin 4 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin 2 Input Port Pin 2 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves 7.1. IOLink data BNI IOL322E12, extended with valve terminal connector with 22/24 valves Transmission rate COM2 (38.4 kbaud) Minimum cycle time 5.1 ms Process data length 2 byte input, 6 byte output 7.2. Process Data/Input Data www.balluff.com 23

* Valve 12 Coil B Valve 11 Coil B Valve 1 Coil B Valve 9 Coil B Valve 8 Coil B Valve 7 Coil B Valve 6 Coil B Valve 5 Coil B Valve 4 Coil B Valve 3 Coil B Valve 2 Coil B Valve 1 Coil B * Valve 12 Coil A Valve 11 Coil A Valve 1 Coil A Valve 9 Coil A Valve 8 Coil A Valve 7 Coil A Valve 6 Coil A Valve 5 Coil A Valve 4 Coil A Valve 3 Coil A Valve 2 Coil A Valve 1 Coil A Output Port 7 Pin 4 Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3 Pin 4 Output Port 2 Pin 4 Output Port 1 Pin 4 Output Port Pin 4 Output Port 7 Pin 2 Output Port 6 Pin 2 Output Port 5 Pin 2 Output Port 4 Pin 2 Output Port 3 Pin 2 Output Port 2 Pin 2 Output Port 1 Pin 2 Output Port Pin 2 Balluff Network Interface / IOLink BNI IOL322E12 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves 7.3. Process Data/ Output Data Byte 2 3 Valve terminal on extension port * No function for V13 Byte 4 5 Valve terminal on extension port * No function for V13 www.balluff.com 24

Parameter data Identification data Read only 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves 7.4. Parameter Data / Demand Data 7hex 7 8hex 8 9hex 9 Ahe x 1 Bhe x 11 1hex 16 11hex 17 12hex 18 Vendor ID Device ID Vendor Name 2 bytes 3 bytes Access rights Default value 378hex x5 D 82 x5 D 83 x5 D 84 BALLUFF Vendor text www.balluff.com Product Name BNI IOL322E12 with BNI IOL751V8K7 BNI IOL322E12 with BNI IOL751V1K7 BNI IOL322E12 with BNI IOL751V13K7 13hex 19 14hex 2 15hex 21 16hex 22 17hex 23 18hex 24 Product ID Product text DPP SPDU Parameter Data Subindex width Serial number Hardware revision Firmware revision Applicationspecific tag 16 bytes 32 bytes BNIAR with BNI6N BNI6P BNI6R Sensor hub M12 extended with valve plug CG25 24 25 Sensor hub M12 extended with Valve plug CG13 24 23 Sensor hub M12 extended with Valve plug CG2324 22 23 hex hex DPP SPDU Parameter Data Access rights Default Subindex width Value 4hex 64 116 Inversion of the inputs 2 bytes Read/write hex 41hex 65 116 Config. inputs/outputs 2 bytes Read/write hex 42hex 66 138,4 Safe state output 1 bytes Read/write hex 43hex 67 18 Safe state on Pin 2 2 bytes Read/write hex 44hex 68 123 Voltage monitoring 3 bytes Read 45hex 69 14 Output monitoring 6 bytes Read 46hex 7 116 Actuator warning 2 bytes Read 54hex 84 55hex 85 Serial number 16 bytes Read/write 16xhex Extension port 1 byte Read/write 2, 3, 4hex www.balluff.com 25

Direction Port 7 Pin 4 Direction Port 6 Pin 4 Direction Port 5 Pin 4 Direction Port 4 Pin 4 Direction Port 3 Pin 4 Direction Port 2 Pin 4 Direction Port 1 Pin 4 Direction Port Pin 4 Direction Port 14 Pin 4 Direction Port 13 Pin 4 Direction Port 12 Pin 4 Direction Port 11 Pin 4 Direction Port 1 Pin 4 Direction Port 9 Pin 4 Direction Port 8 Pin 4 Inversion of Port 6 Pin 4 Inversion of Port 5 Pin 4 Inversion of Port 4 Pin 4 Inversion of Port 3 Pin 4 Inversion of Port 2 Pin 4 Inversion of Port 1 Pin 4 Inversion of Port Pin 4 Inversion of Port 7 Pin 2 Inversion of Port 6 Pin 2 Inversion of Port 5 Pin 2 Inversion of Port 4 Pin 2 Inversion of Port 3 Pin 2 Inversion of Port 2 Pin 2 Inversion of Port 1 Pin 2 Inversion of Port Pin 2 Balluff Network Interface / IOLink BNI IOL322E12 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves Inversion of the inputs 4hex 8 7 6 5 4 3 2 1 16 15 14 13 12 11 1 9 Inversion of port (x): Normal 1 Inverted Configuration of inputs/outputs 41hex Direction of port (x): Input 1 Output www.balluff.com 26

Valve 8 Coil A Valve 7 Coil A Valve 6 Coil A Valve 5 Coil A Valve 4 Coil A Valve 3 Coil A Valve 2 Coil A Valve 1 Coil A * Valve 12 Coil A Valve 11 Coil A Valve 1 Coil A Valve 9 Coil A Safe state Port 3 Pin 4 Safe state Port 2 Pin 4 Safe state Port 1 Pin 4 Safe state Port Pin 4 Safe state Port 6 Pin 4 Safe state Port 5 Pin 4 Safe state Port 4 Pin 4 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves Safe state of Outputs 42hex Safe state of the outputs on Pin 4 42hex The safe state parameter makes it possible to configure the outputs in case of a fault. If no IOLink communication is possible or the "valid flag" of the output process data has not been set by the master, then each output adopts the configured status. The following statuses can be configured for each pin. 4 3 2 1 8 7 6 5 Byte 2 3 Valve terminal on extension port 23 21 19 17 * No function for V13 Byte 4 5 Subindex Subindex 15 13 11 9 7 5 3 1 Valve terminal on extension port www.balluff.com 27

Safe state Port 3 Pin 2 Safe state Port 2 Pin 2 Safe state Port 1 Pin 2 Safe state Port Pin 2 Safe state Port 6 Pin 2 Safe state Port 5 Pin 2 Safe state Port 4 Pin 2 Valve 8 Coil B Valve 7 Coil B Valve 6 Coil B Valve 5 Coil B Valve 4 Coil B Valve 3 Coil B Valve 2 Coil B Valve 1 Coil B * Valve 12 Coil B Valve 11 Coil B Valve 1 Coil B Valve 9 Coil B Balluff Network Interface / IOLink BNI IOL322E12 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves Byte 6 7 Valve terminal on extension port 24 22 2 18 * No function for V13 Byte 8 9 16 14 12 1 8 6 4 2 Valve terminal on extension port Safe state of the outputs on Pin 2 43hex 4 3 2 1 8 7 6 5 bin Value dec Output state Output is V 1 1 Output is 24V 1 2 Current status is maintained 11 3 Not defined www.balluff.com 28

Overload UA Outputs off (UA too low) Undervoltage UA Undervoltage US Shortcircuit Port 7 Pin 1 Shortcircuit Port 6 Pin 1 Shortcircuit Port 5 Pin 1 Shortcircuit Port 4 Pin 1 Shortcircuit Port 3 Pin 1 Shortcircuit Port 2 Pin 1 Shortcircuit Port 1 Pin 1 Shortcircuit Port Pin 1 Outputs off (UA too low) Undervoltage UA Undervoltage US1 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves Voltage monitoring 44hex 8 7 6 5 4 3 2 1 12 11 9 Byte 2 Bit 7 6 5 4 3 2 1 23 2 19 17 Valve terminal on extension port www.balluff.com 29

* Valve 12 Coil B Valve 11 Coil B Valve 1 Coil B Valve 9 Coil B Valve 8 Coil B Valve 7 Coil B Valve 6 Coil B Valve 5 Coil B Valve 4 Coil B Valve 3 Coil B Valve 2 Coil B Valve 1 Coil B * Valve 12 Coil A Valve 11 Coil A Valve 1 Coil A Valve 9 Coil A Valve 8 Coil A Valve 7 Coil A Valve 6 Coil A Valve 5 Coil A Valve 4 Coil A Valve 3 Coil A Valve 2 Coil A Valve 1 Coil A Shortcircuit Port 7 Pin 4 Shortcircuit Port 6 Pin 4 Shortcircuit Port 5 Pin 4 Shortcircuit Port 4 Pin 4 Shortcircuit Port 3 Pin 4 Shortcircuit Port 2 Pin 4 Shortcircuit Port 1 Pin 4 Shortcircuit Port Pin 4 Shortcircuit Port 7 Pin 2 Shortcircuit Port 6 Pin 2 Shortcircuit Port 5 Pin 2 Shortcircuit Port 4 Pin 2 Shortcircuit Port 3 Pin 2 Shortcircuit Port 2 Pin 2 Shortcircuit Port 1 Pin 2 Shortcircuit Port Pin 2 Balluff Network Interface / IOLink BNI IOL322E12 7 Configuration Extended with Valve Terminal Connector with 22/24 Valves Monitoring the outputs 45hex 8 7 6 5 4 3 2 1 16 15 14 13 12 11 1 9 Byte 2 3 23 21 19 17 15 13 11 9 7 5 3 1 Extension port * No function for V13 Byte 4 5 Subindex 24 22 2 18 16 14 12 1 8 6 4 2 Extension port * No function for V13 Setting the serial number 54hex The serial number has a default value of 16xhex. In order to use the "Identity" master validation mode, a serial number can be set using this parameter. This prevents a device from connecting to the wrong master port. www.balluff.com 3

7 Configuration Extended with Valve Terminal Connector with 22/24 Valves 7.5. Errors Error Code x811 not available x812 Subindex not available x823 Access Denied x833 Parameter length overrun x834 Parameter length underrun x835 Function not available x836 Function temporarily unavailable 7.6. Events IOLink Revision 1. Event Code x5112 Low sensor voltage (US) x5114 Low actor voltage (UA) x541 Output Stages x8df Retry at the extension port x8df1 Device lost at the extension port x8df2 Wrong device at the extension port IOLink Revision 1.1 Event Code x5111 Low sensor voltage (US) x5112 Low actor voltage (UA) x771 Short circuit x8df Retry at the extension port x8df1 Device lost at the extension port x8df2 Wrong device at the extension port www.balluff.com 31

Balluff Network Interface / IOLink BNI IOL322E12 8 IOLink functions 8.1. IOLink Version 1. / 1.1 This device can be operated with an IOLink master according to IOLink version 1. and version 1.1. Versionspecific functions such as data storage (version 1.1) are only supported in combination with a suitable IOLink master. 8.2. Data Storage Each IOLink master of IOLink version 1.1 features data storage in which an image of the IOLink device configuration can be stored. When a device is replaced, the stored configuration is automatically transferred to the new device. This guarantees minimal downtime. Validation must be switched on in order to use the data storage. For information about the configuration of data storage and validation, please refer to the user's guide of the respective IOLink master. 8.3. Block Configuration 8.4. Resetting to Factory Settings The device supports block configuration. This allows all parameters in a data block to be consistently imported from a controller or a configuration tool into the device. The factory settings on the device can be restored by running the "restore factory settings" system command. x82 must be written to 2 Subindex for the command. The extension port setting is not reset in this process. www.balluff.com 32

9 Technical Data 9.1. Dimensions 9.2. Mechanical Data Housing material Stainless steel (V4A) IOLink Port IOLink port M12, Acoded, male I/O ports Weight Dimensions (L W H) M12x1, Acoded, female (8 piece) ca 53 g 181.6 7 37.9 mm 9.3. Electrical Data Operating voltage 18 3.2 V DC, corresponding to EN 611312 Ripple < 1% Current consumption without load (extension off) 4 ma Load current (PIN 1) Max. 2 ma (temperaturedependent) Total current US 3.5 A Inputs PNP, type 3 9.4. Operating conditions Operating temperature 5 C +7 C Storage temperature 25 C +7 C EMC Immunity tests: Emission tests: EN 6162:25 AC:25 EN 6164:27 A1:211 Degree of protection IP69 (only when pluggedin and screwed together) Vibration/shock EN 668 Part 26/27 www.balluff.com 33

Balluff Network Interface / IOLink BNI IOL322E12 1 Function indicators 1.1. Function indicators UA US1 COM LED indicator module status Indicator Function COM Green No communication Green, negative pulsed Communication OK US1 LED Green Module supply OK Red Undervoltage < 18 V UA LED Green Actuator supply OK Red Undervoltage < 18 V www.balluff.com 34

1 Function indicators Digital LED indicators for inputs/outputs Extension port LED 2, input/output on Pin 4 and LED 1, input/output on Pin 2 Indicator Yellow Input/output signal = 1 Red Sensor supply shortcircuit Off Input/output signal = Request / Signal The table is valid if the extension port is active. If the extension port is used as a standard I/O, then the description from "Digital LED indicators for inputs/outputs" can be used. Status Green Green, flashing Flashing red rapidly Red Function IOLink connection active No IOLink connection or faulty IOLink device Incorrect IOLink device or incorrect configuration (x55) Short circuit www.balluff.com 35

Balluff Network Interface / IOLink BNI IOL322E12 11 Appendix 11.1. Type code BNI IOL322E12 Balluff Network Interface IOLink interface Functions 32 = 16 inputs/outputs Variants 2 = with IOLink 1.1 extension port Mechanical configuration E12 = Stainless steel V4A Bus connection: 1x M12x1 external threads, I/O ports: 8 x M12x1, internal thread 11.2. Ordering information Type code BNI IOL322E12 Order code BNIAR www.balluff.com 36

Notes www.balluff.com 37

No. 931699 E Edition J16 Subject to modification www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Phone +49 7158 173 Fax www.balluff.com +49 7158 51 balluff@balluff.de