Connections to PAD-LA Series

Similar documents
Connecting to the PAK-A Series

Power Supply Controller Power Supply Controller PIA4800 Series

Connection to the PWR Series

Variable Regulated DC Power Supplies PAD-LA Series

Variable Regulated DC Power Supplies PAD-LA Series

Variable-switching Regulated DC Power Supplies PAS Series

Digital Keypad Introduction

MAIN PCB (The small one)

Connection to the PIA4820

BehringerMods.com. Instructions for modification of Behringer SRC analog inputs and outputs

High Power (15W + 15W) Stereo Amplifier

Connecting a Cisco Reader Module

User's Guide. Model W 3-in-1 Switching DC Power Supply

Microsystems. SCI-6 Sound Card Interface Kit Version 1.09 January 2015

Images Scientific OWI Robotic Arm Interface Kit (PC serial) Article

Analog Input and Output Options for Syringe Pumps

Wavy for PAS&PWR Ver. 5.0

LCD Readout Digital Pressure Switch

Absolute Rotary Encoder E6C-N. Ordering Information. Ideal for Stepping Motor Tripping Detection and Position Control of Loaders or Unloaders

Wavy for PAT-T Ver. 5.2

Phi-panel backpack assembly and keypad options Dr. John Liu 12/16/2012

These are the illustrated step-by-step guidelines for upgrading your Quad 306 with the Dada Electronics upgrade-kit.

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

V TU24 V350-J-TU24

Installation Instructions

4 Channel DMX Driver Instruction Manual

BuffaloLabs WiFi Lantern Assembly guide version 1

Blue Point Engineering

Additional board ZIB2-PDx-N for Plug & Drive motors PDx-N

CM-110SK Standalone Keypad Installation Instructions

INSTALLATION INSTRUCTIONS

1. PRODUCT INTRODUCTION Description 1-2. Feature...

4.7 Expansion Module MAC00-FS1/FS4

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series

Single Door Standalone Access Control User Manual

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

User s Manual PWR1201L PWR1201ML PWR1201MH PWR1201H. Regulated DC Power Supply PWR-01 Series. 400W model. 800W model. 1200W model

8000 Series: Installation Supplement R2-1-12

EQ573 Assembly guide. EQ573 Assembly guide Main board 1. Diodes. 2. Resistors (1) 3. Test pins. 4. Ceramic capacitors.

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

HSY-S209 EM Metal waterproof access control system User Manual

GL2200 MIXING CONSOLE

IB080QM65VA3 Part Number

the Interactive Catalog

MAIN PCB (The small one with the square cut out from one side)

Pico Amiga ATX power adaptor install guide

SDG1400 User s Guide

Uzebox Kit Assembly Guide

Multi-Axis Step Motor Controller

MobileView Junction Box

Industrial Power Supply Connectors

TEC 2000 INSTRUCTION MANUAL TEC SERIES

ANSI C Dimming Receptacles

Through/Ground Conductor/Ex and Double-Potential Terminal Blocks 1 (1.5) mm, 2000 Series

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

Series Watt DC Power Supplies

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Muti-Range Bench-Top DC Power Supply PSB-2000 series

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx

solutions for teaching and learning

Track Power Control. General:

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

FITTING INSTRUCTIONS

Programmable D.C. Electronic Load

Insert the male, 90 angled, 2x10 connectors into the corresponding 2x10 sockets and put them in place, flat under the PCB. Solder.

USB-to-I2C. Ultra Hardware User s Manual.

4 Connection and interface

Power Supply and Fan Module Installation

Information. EX260 Integrated Type (For Output) Serial Transmission System 5 Port Solenoid Valve mm. Series SY/SV/VQC/S0700

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

SRI-02 Speech Recognition Interface

Subject: 24 Volt Hand Dryer Replacement Option Conversion Kit Package v Hand Dryer to 115v / 230v Hand Dryer

Tubbutec SH-1oh1 µtune

Connecting a Cisco Input Module

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

This connector has been added along with the signals needed by the REEL SAFE system

JetI/O 6500 Demo Box

GSV-1A4 M12/2 M12/2. Highlights

Micro USB Lamp Kit ESSENTIAL INFORMATION. Version 2.0 DESIGN A STYLISH LAMP WITH THIS

ENGR 210 Lab1. Ohm's Law

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution

CHAPTER Wi r i n g NOTICE:

BC-5000 Field Calibration Procedure 55 AMP

Installing Keypad and Backplate

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

WINSTA. Full Line Catalog 2008/2009

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Single cable kit for the FCB1010

**** Never plug in your LED driver to AC power until all wiring is complete ****

XYLOPHONE KIT ESSENTIAL INFORMATION. Version 2.0 CREATE YOUR OWN ELECTRONIC MUSICAL INTRUMENT WITH THIS

RTC 300/RTC 600 Installation instructions scan

MegaTrak MCU-9000 Harness Wiring

Transcription:

Connections to PAD-LA Series 1. Control Parameters Four different methods (PAD-LA-1 through PAD-LA-4 connections) can be used to make connections to the PAD-LA series, depending on the control parameters. The following parameters can be controlled. Table 1 Control Parameters Can be controlled No mark Uncontrollable Subject to certain conditions Connection PAD-LA-1 PAD-LA-2 PAD-LA-3 PAD-LA-4 Control board OP01-PIA *1 OP02-PIA Peripheral option TU02+SH TU02 Output voltage setting Output current setting Output voltage readback Power switch OFF *2 *2 Output current readback (accuracy 0.3 % of full scale) Output ON/OFF C.V mode monitoring *2 *2 C.C mode monitoring *2 *2 Alarm monitoring *3 *2 *2 *1. OP01-PIA cannot control models with a rated output voltage exceeding 500 V. *2. Installation by us of a DIN connector is required (some types are not supported) *3. Monitors the activation of the overvoltage protection circuit, overheat protection circuit, voltage detection circuit, and overcurrent protection circuit.

2. PAD-LA-1 When the OP01-PIA and the terminal unit are used together with the shunt-unit SH series. OP01-PIA cannot control models with a rated output voltage exceeding 500 V. To perform C.C mode monitoring, C.V mode monitoring, or alarm monitoring, a modification by installing a DIN connector on the PAD-LA series is necessary. For details, contact your Kikusui distributor/agent. The application of the SH series allows readback of accurate current values (with an accuracy of 0.3 % of full scale). To connect the OP01-PIA to the SH series, use the flat cable accompanying the OP01-PIA. To connect the SH series to the, use the flat cable accompanying the SH series. To connect the to the PAD-LA series, use the cable accompanying the. For the connection procedure, see the operation manual for each device. Setting of ID is unnecessary J3 connection cable accompanying OP01-PIA J1 / J2 Flat cable accompanying SH series J1 J3 J2 PAD-LA series J2 connection cable accompanying + J1 J2 Shunt unit SHXXX + Flat cable accompanying OP01-PIA or optional shielded flat cable Check the polarity. + Load Fig.1 PAD-LA-1 connections

Angle attachment Attach the angle to the 5th hole from the bottom Attach the angle to the 3rd hole from the bottom Detailed wiring To the terminal board on the rear panel of the PAD-LA series T U0 2- PI A J2 DIN PLUG To the DIN connector ID J1 J3 GN D Connection flat cable provided Fig.2 connections 15 Brown CONTROL terminal board No. 32 (TRIP)*1 14 Brown CONTROL terminal board No. 31 (TRIP COM)*1 13 Black CONTROL terminal board No. 11 (OUTPUT)*1 12 Black CONTROL terminal board No. 10 (OUTPUT COM)*1 10 White Negative output terminal (PAD110-20LA or 250-8LA)*2 8 Gray Negative output terminal (PAD36-60LA, 60-35LA, or 72-30LA)*2 7 Violet Negative output terminal (PAD16-100LA)*2 6 Blue Not used. Remove the wire. 5 Green Not used. Remove the wire. 4 Yellow CONTROL terminal board No. 7 (CC)*1 3 Orange CONTROL terminal board No. 2 (COM)*1 2 Red Not used. Remove the wire. 1 Brown CONTROL terminal board No. 3 (CV)*1 *1 Since the J3 Wire Kit that comes with the has crimp terminals at the tip of the wires, cut the crimp terminals off from the wires that are to be connected to the control terminal of the PAD-LA. Then, strip 9 mm of the covering and attach the wires. *2 One of the wires 7, 8, and 10 of the J3 Wire Kit is used depending on the model. Remove the wires for the models that are not applicable. In addition, replace the applicable wire with the extension cable for PAN-A with M4 crimped terminal that comes with the.

3. PAD-LA-2 When the OP01-PIA and the terminal unit are used. OP01-PIA cannot control models with a rated output voltage exceeding 500 V. To perform C.C mode monitoring, C.V mode monitoring, or alarm monitoring, a modification by installing a DIN connector on the PAD-LA series is necessary. For details, contact your Kikusui distributor/agent. To connect the OP01-PIA to the, use the flat cable accompanying the OP01-PIA. To connect the TU02- PIA to the PAD-LA series, use the connection cable accompanying the. For the connection procedure, see the operation manual for each device. Setting of ID is unnecessary J3 connection cable accompanying OP01-PIA J1 / J2 J3 J2 J1 J2 connection cable accompanying Flat cable accompanying OP01-PIA or optional shielded flat cable PAD-LA series + + Load Fig.3 PAD-LA-2 connections

4. PAD-LA-3/PAD-LA-4 When the OP01-PIA or OP02-PIA is used. OP01-PIA cannot control models with a rated output voltage exceeding 500 V. In PAD-LA-3 connections, connect J1/J2 on the OP01-PIA to the PAD-LA series (on the rear of the control terminal board) in accordance with the pin layout shown below, see Chapter 8, OP01-PIA of PIA4800 series operation manual. In PAD-LA-4 connections, connect CH1/CH2 on the OP02-PIA to the PAD-LA series (on the rear of the control terminal board) in accordance with the pin layout shown below, see Chapter 9, OP02-PIA of PIA4800 series operation manual. OP01-PIA(PAD-LA-3) or OP02-PIA(PAD-LA-4) OP02-PIA(PAD-LA-4) If the cable length exceeds 50 cm, use a shielded cable. The cable length must not exceed 2 m. PAD-LA series TYPE III On the rear of the control terminal board Fig.4 Table 2 PAD-LA-3/PAD-LA-4 connections Pin layout for PAD-LA-3 and PAD-LA-4 PAD-LA series CONTROL terminal board OP01-PIA J1/J2 OP02-PIA CH1/CH2 Remarks Terminal 3 4 A Output voltage control Terminal 2 2 B Common for output voltage common Terminal 7 5 C Output current control Terminal 6 2 D Common for output current control Terminal 11? E Output ON/OFF Terminal 10? F Common for output ON/OFF

5. Preparation for Starting Control Settings on PAD-LA unit Before starting control operation, make the following settings: 1 Set switches S1 and S2 on the front control panel to the upper position (remote settings for C.C and C.V). 2 Turn the output setting knob clockwise until it stops. To prevent the output setting knob from rotating, use of a guard cap is recommended. Note that the calibration value changes if the output setting knob is turned following calibration. Setting and checking PAD-LA Model ID The newest version of ID list can be downloaded from download service of Kikusui website (http://www.kikusui.co.jp/en/download/). Table 3 ID list ID No. Model Outputcurrent setting range [V] Outputcurrent setting range [A] SH series Switch setting position on *1 the control board 100/200 *2 101/201 *2,*3 140 PAD16-100LA 0-16.000 0-100.00 Special orders H L/NC 141 PAD36-60LA 0-36.000 0-60.00 Special orders H L/NC 146 PAD36-100LA 0-36.000 0-100.00 Special orders H L/NC 142 PAD60-35LA 0-60.00 0-35.000 SH50 H L/NC 147 PAD60-60LA 0-60.00 0-60.00 Special orders H L/NC 143 PAD72-30LA 0-72.00 0-30.000 SH50 H L/NC 144 PAD110-20LA 0-110.00 0-20.000 SH50 H L/NC 149 PAD110-32LA 0-110.00 0-32.000 SH50 H L/NC 145 PAD250-8LA 0-250.00 0-8.000 SH10 H L/NC 150 PAD250-15LA 0-250.00 0-15.000 SH50 H L/NC *1. The setting positions for the switch of OP01-PIA or OP02-PIA *2. The number "100" and "101" are applied for the switch of Channel 1, "200" and "201" are for the switch of Channel 2. *3. The setting positions of "L" is used for OP01-PIA, "NC" is used for OP02-PIA. Set the OFF-MODE switch of the remote control setup switch to A. For the ID settings, see 3.4, Configuration Software of PIA4800 series operation manual.

Calibrating the PAD-LA series When a new Model ID has been set, be sure to conduct calibration. Calibration can be performed for two parameters: output voltage and output current. For the calibration procedure, see Chapter 3, Calibration by Device Configuration of PIA4800 series operation manual. Checking PAD-LA performance Following calibration, set a voltage via GPIB or RS232C to check the performance of the PAD-LA. Checking procedure (example) By sending the message NODE 1;CH 1;VSET 12.00 to the PIA4800 series, make sure the preset voltage for the PAD-LA series is set at 12.00 V. 6. Commands For the commands, see Device Messages of Connecting & Programming Guide.