sales@jumo.co.uk info.us@jumo.net Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology Brief description This pressure transmitter is used as the core product for the MIDAS range for applications requiring reliable implementation of measuring tasks with long-term stability and excellent priceperformance ratio. The MIDAS range provides solutions for all applications on the basis of this core product. The innovative and patented sensor design of the specifically developed ceramic sensor provides excellent long-term stability of < 0. %. It can be used for recording relative pressures of.6 bar to 60 bar in gaseous or liquid media. Type 4000 with QUICKON Type 4000 with M connector Customer benefits process-reliable Through constructive measures, the pressure transmitter achieves excellent vibration resistance and enables application under high vibration load, as occurs in commercial vehicles for example. The throughput through the fully automatic measuring and calibration devices, the diagnostic function of the switching circuit, and the full final inspection complete the high standard of quality. economic The QUICKON quick-clamp technology enables quicker and safer installation. The connection is even guaranteed with any temperature fluctuations that may occur thanks to the spring contacts. This electrical connection means that installation times can be shortened and as a result, costs are reduced by 60 % compared to conventional connection options. versatile The universal application is reflected by the wide choice of measuring ranges, process connections, and electrical connections. Special features long-term stability < 0. % new level of quality for the OEM sector 60 % quicker device installation with the QUICKON quick-clamp technology temperature compensation range increased by 50 % to -0 C to +00 C.5 times more vibration resistance than the industry standard made in Germany
sales@jumo.co.uk info.us@jumo.net Page /0 Technical data General Information Reference conditions DIN 6086 and DIN EN 60770 Sensor Measuring principle Thick film on ceramic bodies (piezo-resistive) Admissible load changes > 0 million, 0 % to 00 % measuring range Position Mounting position Any Calibration position Device upright, process connection at the bottom Output Analog output a Current Output 405 4 ma to 0 ma, -wire Voltage Output 4 DC 0.5 V to 4.5 V, -wire, ratiometric 0 % to 90 % of the voltage supply Output 45 DC 0 V to 0 V, -wire Output 48 DC V to 5 V, -wire Output 40 DC V to 6 V, -wire Step response T 90 ms Burden Current 4 ma to 0 ma, -wire R L (U B -8 V) 0.0 A (Ω ) Voltage DC 0.5 V to 4.5 V, -wire R L 5kΩ DC 0 V to 0 V, -wire R L 0 kω DCV to5v, -wire R L 0 kω DCV to6v, -wire R L 0 kω a Further outputs are available upon request. Mechanical features Process connection Material Stainless steel 04 for push-in fitting Brass, nickel-plated (process connection 8) Process seal Material, internal a Seal 600 EPDM Seal 60 FPM, standard Seal 60 CR Seal 604 FFPM Seal 609 NBR Material, external a for G /4 FPM (process connection 5) Sensor Material Ceramic Al O 96 % Case Material Stainless steel 04
sales@jumo.co.uk info.us@jumo.net Page /0 Electrical connection Material Attached cable PBT-GF0, PVC (electrical connection ) QUICKON PBT-GF0 (electrical connection ) Round plug M PBT-GF0, stainless steel 0 L (electrical connection 6) Bayonet connector PBT-GF0 (electrical connection 5) Cable socket PBT-GF0, PA, silicone (electrical connection 6) Weight 70 g with process connection 50 (G /4) a Ensure the medium durability of the seal material! Environmental conditions Admissible temperatures Medium -0 C to +5 C Ambient -0 C to +85 C Storage -40 C to +5 C Admissible humidity Operation 00 % rel. humidity including condensation on the device outer case Storage 90 % rel. humidity without condensation Admissible mechanical load Vibration resistance a 50 g for 0 Hz to 000 Hz Shock resistance b 50 g for ms 00 g for ms Electromagnetic compatibility Interference emission c Class B Interference immunity c Industrial requirement Protection type d Attached cable IP67 (electrical connection ) QUICKON e IP67 (electrical connection ) Round plug M f IP67 (electrical connection 6) Bayonet connector f IP67 (electrical connection 5) Cable socket f, g IP65 (electrical connection 6) a IEC 60068--6 b IEC 60068--7 c EN 66-- d EN 6059 e Connecting cable diameter, minimum.5 mm, maximum 6 mm f The protection type is only achieved with a suitable mounted counter piece. g Connecting cable diameter, minimum 6 mm, maximum 8 mm
sales@jumo.co.uk info.us@jumo.net Page 4/0 Measuring range and accuracy Measuring range Linearity a Accuracy at Long-term 0 C d -0 C to +85 C e -0 C to +00 C e stability b Auxiliary energy Overload capacity c Burst pressure bar % MSP % MSP % MSP % MSP % MSP bar bar per year 0 bar to.6 bar relative pressure 0.5 0.5 0.5 0. 6 0 bar to.5 bar relative pressure 6 0 bar to 4 bar relative pressure 5 0 bar to 6 bar relative pressure 5 0 bar to 0 bar relative pressure 0 8 0 bar to 6 bar relative pressure 50 75 0 bar to 5 bar relative pressure 50 75 0 bar to 40 bar relative pressure 0 00 0 bar to 60 bar relative pressure 0 00 - bar to +0.6 bar relative pressure 6 - bar to +.5 bar relative pressure 6 - bar to + bar relative pressure 5 - bar to +5 bar relative pressure 5 - bar to +9 bar relative pressure 0 8 - bar to +5 bar relative pressure 50 75 - bar to +4 bar relative pressure 50 75 a Linearity according to limit point setting b Reference conditions EN 698- c All pressure transmitters are vacuum-proof. d Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring range end value e Includes: linearity, hysteresis, repeatability, deviation of measuring range initial value and measuring range end value, thermal effect on measuring range start and measuring span Voltage supply U B a 4 ma to 0 ma, -wire (output 405) DC 8 V to 0 V, rated voltage supply DC 4 V DC 0.5 V to 4.5 V, -wire (output 4) DC V to 5.5 V, rated voltage supply DC 5 V, ratiometric output 0 % to 90 % of the voltage supply DC 0 V to 0 V, -wire (output 45) DC.5 V to 0 V, rated voltage supply DC 4 V DC V to 5 V, -wire (output 48) DC 8 V to 0 V, rated voltage supply DC 4 V DC V to 6 V, -wire (output 40) DC 8 V to 0 V, rated voltage supply DC 4 V Current consumption 4 ma to 0 ma, -wire (output 405) 5 ma DC 0.5 V to 4.5 V, -wire (output 4) ma DC 0 V to 0 V, -wire (output 45) ma DC V to 5 V, -wire (output 48) ma DC V to 6 V, -wire (output 40) ma Reverse voltage protection Yes Electrical circuit SELV a Residual ripple: the voltage peaks must not exceed or fall below the specified voltage supply values!
sales@jumo.co.uk info.us@jumo.net Page 5/0 Dimensions Electrical connection Attached cable QUICKON 6 Round plug M 5 Bayonet connector 6 Cable socket
sales@jumo.co.uk info.us@jumo.net Page 6/0 Process connection 8 Plug connector for pipe/hose 6 4 DN 6 50 G/4 504 G/ 5 /4-8 NPT 5 G/4 547 RP /8 inside * * 56 7/6-0 UNF A Profile seal G /4 * Extra code 60 pressure channel Ø 8 mm
sales@jumo.co.uk info.us@jumo.net Page 7/0 Connection diagram The connection diagram in the data sheet provides preliminary information about the connection options. For the electrical connection only use the installation instructions or the operating manual. The knowledge and the correct technical execution of the safety information/instructions contained in these documents are mandatory for installation, electrical connection, startup, and for safety during operation. Connection Terminal assignment a 4 Attached cable QUICKON 6 Round plug M 5 Bayonet connector 4 ma to 0 ma, -wire (output 405) Voltage supply DC 8 to 0 V U B /S+ 0V/S- WH BN DC 0.5 V to 4.5 V ratiometric (output 4) Voltage supply DC V to 5.5 V Ratiometric output 0 % to 90 % of the voltage supply U B 0V/S- S+ WH BN GN DC 0 V to 0 V, -wire (output 45) Voltage supply DC.5 V to 0 V U B 0V/S- S+ WH BN GN DC V to 5 V, -wire (output 48) DC V to 6 V, -wire (output 40) Voltage supply DC 8 V to 0 V U B 0V/S- S+ WH BN GN Functional bonding conductor FB b - - 4 - - 6 Cable socket a b Figure: Connection to the pressure transmitter The pressure transmitter has to be connected to the potential equalization system of the plant through the electrical connection or process connection. Colour coding: connecting cable round plug M BN Brown WH White BU Blue 4 BK Black The colour coding is only valid for A-coded standard cables!
sales@jumo.co.uk info.us@jumo.net Page 8/0 Order details () Basic type 4000 JUMO MIDAS C08 OEM pressure transmitter basic () Basic type extension 000 None 999 Special version () Input 455 0 bar to.6 bar relative pressure 456 0 to.5 bar relative pressure 457 0 bar to 4 bar relative pressure 458 0 bar to 6 bar relative pressure 459 0 bar to 0 bar relative pressure 460 0 bar to 6 bar relative pressure 46 0 bar to 5 bar relative pressure 46 0 bar to 40 bar relative pressure 46 0 bar to 60 bar relative pressure 479 - bar to +0.6 bar relative pressure 480 - bar to +.5 bar relative pressure 48 - bar to + bar relative pressure 48 - bar to +5 bar relative pressure 48 - bar to +9 bar relative pressure 484 - bar to +5 bar relative pressure 485 - bar to +4 bar relative pressure 999 Special measuring range for relative pressure (4) Output 405 4 ma to 0 ma, -wire 4 0. 5 V to 4.5 V, -wire, ratiometric 45 0 V to 0 V, -wire 48 V to5v, -wire 40 V to6v, -wire 999 Special version (5) Process connection 8 Push-in fitting for pipe/hose 6 4 DN 6 50 G/4 DIN EN 87 504 G/ DIN EN 87 5 /4-8 NPT DIN EN 87 5 G/4 DIN 547 Rp /8 inside 56 7/6-0 UNF (6) Process connection material 0 CrNi (stainless steel) (7) Material seal 600 EPDM 60 FPM a 60 CR 604 FFPM 609 NBR 999 Special material (8) Electrical connection Attached cable b
sales@jumo.co.uk info.us@jumo.net Page 9/0 Quickon 6 Round plug M 5 Bayonet connector DIN 7585-A.-.-Sn/K 6 Cable socket DIN EN 750-80, Form A, ex DIN 4650 99 Special version (9) Extra codes 000 None 59 Choke in the pressure channel 64 Oil and grease free 60 Enlarged pressure channel c 876 Test report a Standard b The standard cable length is m. Further lengths are available upon request. c Diameter Ø 8 mm for process connection 5 and 5; ean enlarged pressure channel is only available in connection with the seal material 60. () () () (4) (5) (6) (7) (8) (9) Order code / - - - - - - /,... a Order example 4000 / 000-460 - 4-504 - 0-600 - 6 / 59 a List extra codes in sequence, separated by commas. Minimum order volume for manufacturing devices: Minimum order volume for warehouse devices: 5 pieces piece Stock versions Item Description Part no. 4000/000-456-405-50-0-60-/000 0 bar to.5 bar, 4 ma to 0 ma, G /4, FPM, QUICKON 005478 4000/000-458-405-50-0-60-/000 0 bar to 6 bar, 4 ma to 0 ma, G /4, FPM, QUICKON 0054740 4000/000-459-405-50-0-60-/000 0 bar to 0 bar, 4 ma to 0 ma, G /4, FPM, QUICKON 005474 4000/000-460-405-50-0-60-/000 0 bar to 6 bar, 4 ma to 0 ma, G /4, FPM, QUICKON 0054746 4000/000-46-405-50-0-60-/000 0 bar to 5 bar, 4 ma to 0 ma, G /4, FPM, QUICKON 0054748 4000/000-456-405-50-0-60-6/000 0 bar to.5 bar, 4 ma to 0 ma, G /4, FPM, cable socket 00546 4000/000-457-405-50-0-60-6/000 0 bar to 4 bar, 4 ma to 0 ma, G /4, FPM, cable socket 005469 4000/000-458-405-50-0-60-6/000 0 bar to 6 bar, 4 ma to 0 ma, G /4, FPM, cable socket 005460 4000/000-459-405-50-0-60-6/000 0 bar to 0 bar, 4 ma to 0 ma, G /4, FPM, cable socket 00546 4000/000-460-405-50-0-60-6/000 0 bar to 6 bar, 4 ma to 0 ma, G /4, FPM, cable socket 00546 4000/000-46-405-50-0-60-6/000 0 bar to 5 bar, 4 ma to 0 ma, G /4, FPM, cable socket 00546 4000/000-46-405-50-0-60-6/000 0 bar to 5 bar, 4 ma to 0 ma, G /4, FPM, cable socket 005464 4000/000-48-405-50-0-60-6/000 - bar to + bar, 4 ma to 0 ma, G /4, FPM, cable socket 005465
sales@jumo.co.uk info.us@jumo.net Page 0/0 Accessories Item Description Part no. Cable box, straight The PVC connecting cable is m in length and has a 4-pin, straight M 00404585 connector with gold-plated contacts on the device side. Cable box, angled The PVC connecting cable is m in length and has a 4-pin, angled M connector with gold-plated contacts on the device side. 004094