Revision 1 1 Revision INFORMATION This revision applies to the manual "MOVIPRO ADC with PROFINET interface", part number 19298412, edition 04/2012. The following chapter of the manual "MOVIPRO ADC with PROFINET interface" are completely replaced by this revision: Chapter 8.2.1 "Module "SEW Controller" The following chapter amends chapter 9 "Operation" of the manual "MOVIPRO ADC with PROFINET interface": Chapter "Important notes" (page 10) Revision MOVIPRO ADC with PROFINET Interface 3
2 I 0 "SEW Controller" Module MOVIPRO control word 2 "SEW Controller" Module The "SEW Controller" module is always available with MOVIPRO ADC and cannot be deleted. The module occupies two process data words and provides general device information. The following figure gives an overview of process ouptut and input data: MOVIPRO Master SEW Controller MOVIPRO control word MOVIPRO status word 0 4DO... POn... PO120 12 16DI... PIn... PI120 2.1 MOVIPRO control word The following figure shows the assignment of the MOVIPRO control word: Master 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MOVIPRO 0: Download data set 1: Upload data set 2: Upload data set and autorestore 3: Reserved = 0 4: Reserved = 0 5: Reserved = 0 6: System restart 7: Reserved = 0 8 15: Reserved = 0 The following table shows the functions of the MOVIPRO control word: Bit Meaning Explanation 0 Download data set The data on the SD memory card is downloaded to MOVIPRO. Important: Data can only be downloaded when the power section is inhibited. (Controller inhibit or safe stop) 4 Revision MOVIPRO ADC with PROFINET Interface
"SEW Controller" Module MOVIPRO status word I 0 2 Bit Meaning Explanation 1 Upload data set The data is uploaded from MOVIPRO to the SD memory card and is saved. 2 Upload data set and auto-restore The data is uploaded from MOVIPRO to the SD memory card and is saved. In the event of a unit replacement, the saved data is automatically loaded from the SD memory card to the new MOVIPRO unit. 3 5 Reserved 0 = Reserved 6 System restart Irrespective of an error or the status of the communication and control unit "PFH-..", a 0-1-0 changeover of this bit causes a system restart. 7 15 Reserved 0 = Reserved 2.2 MOVIPRO status word The following figure shows the assignment of the MOVIPRO status word: Master 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MOVIPRO 0: Maintenance switch (mains OFF) 1: Toggle 2, 3: Reserved = 0 4: Dataset available 5: Auto-restore configured 6: MOVIPRO warning 7: MOVIPRO error 8 15: Unit status/warning/error number Bits 8 15 are assigned depending on the value of bits 6 and 7 according to the following table: Bit 6 Bit 7 Assignment of bits 8 15 0 0 MOVIPRO unit status 1 0 MOVIPRO warning 0 1 MOVIPRO error The following table shows the diagnostic information of MOVIPRO that is set up for evaluation in the higher-level PLC application. The signals are transferred to the controller via parameters and, if necessary, via the process data channel. The logical communication status "0" signals the status "OK" for each signal to ensure that no asynchronous startup sequences from the bus master and the PLC can cause Revision MOVIPRO ADC with PROFINET Interface 5
2 I 0 "SEW Controller" Module MOVIPRO status word incorrect diagnostic messages when the systems are started up (bus startup with user data = 0). Bit Diagnostic name via bus 0 Maintenance switch (mains OFF) Function and coding Maintenance switch (mains OFF) 1 = Maintenance switch activated (mains off) 0 = OK (not activated) 1 Toggle The toggle bit changes between "0" and "1". The default is 100 ms. The toggle bit shows the correct function of the internal communication and control unit. If the toggle bit fails (no edge change), make sure that the connected drive is switched off via appropriate measures. Appropriate measures are, for example: Disconnection Activate safe stop 2 3 Reserved 0 = Reserved 4 Dataset available 5 Auto-restore configured 6 MOVIPRO warning 7 MOVIPRO error Data are present on the SD memory card and they are identical with those of MOVIPRO. Automatic unit replacement is configured. In the event of a unit replacement, the saved data is automatically downloaded from the SD memory card to the new MOVIPRO unit. For more information, refer to chapter "Service" > "Unit replacement". MOVIPRO warning 1 = MOVIPRO warning present 0 = OK MOVIPRO error 1 = MOVIPRO error present 0 = OK 6 Revision MOVIPRO ADC with PROFINET Interface
"SEW Controller" Module MOVIPRO status word I 0 2 Bit Diagnostic name via bus 8 15 Unit status/warning/error number/ Function and coding Unit status (bit 6 = 0, bit 7 = 0): 0: System startup 1: Ready 10: Data backup: Dataset is uploaded from the MOVIPRO unit to the SD memory card 11: Data backup: Dataset successfully uploaded from MOVIPRO to SD memory card 12: Data backup: Dataset is downloaded from the SD memory card to MOVIPRO 13: Data backup: Dataset successfully downloaded from SD memory card to MOVIPRO Warning (bit 6 = 1, bit 7 = 0) Error number (bit 6 = 0, bit 7 = 1) 1: Configuration No connection to internal power section 2: External IO error 3: Configuration No IPOS present 4: Process data stopped to lower-level devices (GATEWAY) 10: Configuration No configuration available 11: Configuration Connection to configured units could not be established 20: Data backup Upload failed 21: Data backup Upload failed: SD memory card is write protected 22: Data backup Download failed 23: Data backup Safe stop necessary 99: Internal system error 110: Overload on digital outputs 120: Overload sensor voltage group 1 121: Overload sensor voltage group 2 Revision MOVIPRO ADC with PROFINET Interface 7
2 "SEW Controller" Module Data backup via PLC process data specification 2.3 Data backup via PLC process data specification The following figure shows data backup via PLC process data specification: MOVIPRO control word MOVIPRO status word Bit 2: Upload data set and auto restore 0x0A: Data set upload in progress During the data upload, the status display of MOVIPRO indicates ''InI''. Do not switch off MOVIPRO during the upload process! Bit 2: PLC must reset the bit. 0x0B: Upload of data set finished 0x01: Ready 5259008011 8 Revision MOVIPRO ADC with PROFINET Interface
"SEW Controller" Module Digital inputs and outputs I 0 2 2.4 Digital inputs and outputs The following figure shows the assignment of the output and input data for the digital inputs/outputs (12 DI/4 DIO): 4 15:Reserved = 0 3: Binary output DO03 2: Binary output DO02 1: Binary output DO01 0: Binary output DO00 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Master MOVIPRO 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0: Binary input DI00 / status of binary output DO00 1: Binary input DI01 / status of binary output DO01 2: Binary input DI02 / status of binary output DO02 3: Binary input DI03 / status of binary output DO03 4: Binary input DI04 5: Binary input DI05 6: Binary input DI06 7: Binary input DI07 8: Binary input DI08 9: Binary input DI09 10: Binary input DI10 11: Binary input DI11 12: Binary input DI12 13: Binary input DI13 14: Binary input DI14 15: Binary input DI15 Revision MOVIPRO ADC with PROFINET Interface 9
3 Important Information 3 Important Information WARNING Risk of crushing if the drive keeps running unintentionally. The internal bus timeout mechanism of the power section has been implemented on telegram level. All telegram types cause a restart of the timeout mechanism. This includes, for example, read or write parameter services that are used by the following devices/applications: MOVITOOLS MotionStudio Visualization software Control and diagnostics devices Control and diagnostics software If the IEC program stops (MOVI-PLC, CCU), the process data communication between the internal communication and control unit and the internal power section is interrupted. Thus, the drive can keep running with the last valid process data. A stop of the IEC program can be triggered by the following actions: In MOVITOOLS MotionStudio in the parameter tree "Program execution = stop" In the PLC Editor [Online] > [Stop] Severe or fatal injuries. A stop action of the IEC program is only permitted in the following states of the power section: Safe stop Controller inhibit No enable 10 Revision MOVIPRO ADC with PROFINET Interface