VersaPro Non-Metallic Fluorescent

Similar documents
AllPro Hazardous/Corrosive Area Fluorescent

Applications: Page 60. Chemical manufacturing / processing plants Paint manufacturing facilities Bulk truck terminals Refineries

FLUORESCENT FIXTURES

Contender LED Luminaires Enclosed and Gasketed Fixtures

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Applications: Page 54. Waste treatment plants Marine loading terminals Pipeline pumping stations Solvent / cleaning areas

Viamaster LED Series Luminaires For NEC and CEC Governed Hazardous Locations

Nominal. Mounting. Length foot foot RUN Nominal Lengths* Suspension Bracket 1 Studs (Factory installed) Rotating Crossbar

Rig-A-Lite. LED Solutions for Oil and Gas Drilling Applications Advanced lighting for demanding environments

ATX FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

Viamaster LED Series Luminaires For ATEX and IECEx Governed Hazardous Locations

Industrial Baymaster HL LED Luminaire High Bay for Ordinary Locations

Industrial Baymaster LED Luminaire High Bay for Ordinary Locations

FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

EJB Junction Boxes Dimensions Pg. 132

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Project Name. Date. Cat. Number. Type

High Bay Lighting. (ABV2-Series)

Mercmaster LED Low Profile Luminaires Enclosed and Gasketed Fixtures

Rig-A-Lite. LED Solutions for Industrial Applications Advanced lighting for demanding environments

Lighting Fixtures. Abtech offers a full line of our Cleanroom. Lay-In Light Fixtures: Teardrop Light Fixtures:

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

2018 New Models. Table of Content LED FIXTURES. LED Ceiling Fixture LED Wall Sconce LED Mini Pendant 10 LED Vanity 10-13

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

DuroSite TM High Bay Lighting. LED White Lighting Brochure for Industrial Applications.

RL70 INDUSTRIAL FLUORESCENT TUBE LIGHT

11W & 22W: Ex d e mb IIC T6 Gb, Ex tb IIIC T85 C Db II 2GD ABS Assessed: #11-LD PDA

Overall Dimensions AE2M-1000 MADJ MW(X)CBLKMP 1000-MPBM. For Reference Only

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Albeo LED Luminaire LED High Bay Lighting (ABV3 - Series)

CLiP 4X 24VAC EXTERIOR IP67 LINEAR LED ACCENT LIGHTING, LOW-POWER

SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications

PROJECT INFORMATION. Project Name. Catalog #

RSS Series Wired Electronic Ballasts

ROAM Decorative Node Control Specification Guideline Division 16520

LED T8 EXTERNAL DRIVER EXTERNAL DIMMABLE T8 PLASTIC SERIES UL TYPE-C

Decorative luminaires for commercial and retail applications. Acuity Brands Indy Commercial/Retail Lighting

RSS Series Wired Electronic Ballasts

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Diffuser Color (when not illuminated) Light amber hue

LED High Bay FBX. An economical LED high bay Enjoy flexibility and savings along with quality illumination

ROAM 120V-277V Node Control Specification Guideline Division 16520

60 Watt Portable LED Work Area Light - Waterproof - Aluminum Frame - Adjustable Light Head

RSS Series Wired Electronic Ballasts

Supplementary Components WirelessHART products

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Installation & Operation Manual

Terminal Boxes Series 8118

RSS Series Wired Electronic Ballasts

Product Brochure Edition 1. t: f: e: doncastercables.com

ULTRA LED RT8. Recessed Downlight Kit.

PANELITE ENCLOSURE LIGHTS OVERVIEW

Golight Radioray GL-2000-F Flood & Spot Light Combo - wireless remote control - permanent mount

Type 330SA High-Performance Electric Actuator

NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories

Push Buttons and Operator Interface Specifier s Guide Type XVA Indicating Banks and Beacons

KEPLERO MINI HE Efficiency & Interchangeability

Copyright 2012 Lumascape Lighting Industries Pty. Ltd. ABN SPECIFICATIONS IK10 IP68

EESB Parallel Wired Electronic Ballasts

ML20 Series Long-Range Miniature Sensors

SCADAPack Modbus multivariable transmitter

lumenfacade Specification Sheet

Performance Chart Electrical Data

ML17 Series Tru-Vue TM Sensors

Wireless Remote Controlled 50 Watt HID Light (4500 Lumens) with Magnetic Base

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Basic Series 18 mm Diameter Cylindrical Sensors

LIGHTING S. Table of Contents. Lighting Kimball Surfaces & Storage. Price List Effective Dates: Pricing Revision

Ravenna TM. Fixture Options: Ordered Separately from Fixture See page 2. Mounting Options: Ordered Separately from Fixture See pages 3-5

LEONARDO MULTIPOWER Quartz Halogen Fresnel Spotlight

N2S and N2SC Series Control Stations

PLEDFHB-V2. Full-Body LED High Bay WARRANTY & LISTINGS FEATURES MOUNTING OPTIONS ORDERING INFORMATION. Color Temperature. Lumens Watts.

SUN3 LED REV

Make your site feel more secure, maintain your image

COLONIAL BOLLARD LED SERIES

General Specifications

Model KBW 720 Growth chambers with light

Vix 1W Monochromatic - Transparent Screen Model No: VIX US

Performance Chart Electrical Data

Typical Applications Heavy industrial Light manufacturing Warehousing Large indoor ORDERING INFORMATION V V V 2

Ravenna TM. Fixture Options: Ordered Separately from Fixture. See page 2. Mounting Options: Ordered Separately from Fixture.

Plexineon Color Series

DTL DSN Itron Ready Networked Photocontrol Specification Guideline

Technical Datasheet #TDAXTC20 Thermocouple Scanner 20 Thermocouple Channels CAN, SAE J1939 with Electronic Assistant P/N: AXTC20 Description:

3' 0" 6' 0" 5' 6" 5' 6" 5' 0" 5' 0" 5' 7 1/8"

For (2) Single Receptacles: dia. Hole Standard Depth

ER DATALOGGER ER-200. Bluetooth Communication Easy data transfer via wireless bluetooth Wireless range up to 32 ft (10m) No more cables required

OPTICALLY CLEAR DIFFUSERS CT2-LIRA-2L2 CT2-LIRA-2L4 CT2-LIRA-2L8 CT2-CIRA-1L4 CT2-CIRA-2L4

Linear Luminaire with LED Series 6012/5

Bulletin 855E 50 mm Control Tower Stack Lights

CHEP ATEX. IECEx. Explosion proof Camera Housing. and. Certified

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

2" max. 51 mm Ceiling thickness. 10 ¾" 273 mm. Series Lumens Installation Input voltage Version Dimming Options. VB Version B

Level-Lance Model 5400A

Load Disconnect Switches and Motor Switches

COMPACT30 Warning Tower Lights - General Description...J17 Complete Assemblies...J19 Accessories...J20 Technical Information...J21

Flow Measurement SITRANS F M

WE-EF LIGHTING North American Edition RAIL66 Projectors and Floodlights

Transcription:

CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 2 - Groups F & G CSA - Class III CSA - Type 3 R Enclosed & Gasketed Features: Non-Metallic Fluorescent Two models to choose from: enclosed and gasketed or hazardous area. Corrosion resistant, non-metallic FRP housing. Full steel interior channel assembly that reinforces hub entry, and provides continuous ground. Lens catches are non-metallic or optional stainless steel. Standard diffused acrylic lens (optional polycarbonate lens). Closed cell neoprene gasket poured in place for permanent mounting. Spring loaded sockets on all HO models. Locking sockets on RS models made of industrial grade high temperature PBT. Available in standard feed-thru design or optional pendant hub design. Various mounting hardware systems available. 2, 4 & 8 foot models with 2 lamp T8 or T12 designs. 8 foot models are also available with four, 4 foot lamps Compact fluorescent 2 lamp, 2 foot & 4 lamp, 4 foot models Applications: Wash-bays Dairy & livestock facilities Textile mills Workshop areas Processing plants Chemical storage areas Lubrication pits Marine applications Page 36

Catalog Number Logic VPH 8-2 8 1 0 C - ** (1) (2) (3) (4) (5) (6) (7) (8) (1) Series VP - Enclosed & Gasketed VPH - Hazardous Area Non-metallic housing complete with impact resistant acrylic lens. (2) Length (nominal) 2-2 foot 4-4 foot 8-8 foot (3) Number of Lamps 2 - For 2 lamps 4 - For 4 lamps (4 foot fixture, ballast type 2 only and 8 foot fixtures with four, 4 foot lamps, ballast types 1, 4 & 8) (4) Ballast Type 1-265 ma, T8 (0º F & -18º C starting temp, 50/60Hz electronic ballast) 2-270 ma, 2G11 - compact fluorescent (0º F & -18º C starting temp, 50/60Hz electronic ballast) 3-425 ma, T12, IS, (8 foot models only) (+50º F & +10º C starting temp, magnetic ballast) 4-430 ma, T12 (+50º F & +10º C starting temp, magnetic ballast) 7-800 ma, T8, HO (+50º F & +10º C starting temp, electronic ballast) 8-800 ma, T12, RS, HO (-20º F & -29º C starting temp, magnetic ballast) (5) Voltage / Frequency 1-120 Volt 60 Hz. 3-220 to 240 Volt 50/60 Hz.(ballast types 1 & 2 only) 4-240 Volt 60 Hz.(T12 magnetic only) 5-277 Volt 60 Hz. 6-347 Volt 60 Hz. 7-120 to 277 Volt 50/60 Hz.(ballast type 1 only) (6) Mounting Style 0 - Feed-thru c/w 2- ½ npt. hub (standard design) 1 - Feed-thru c/w 2- ¾ npt. hub 2 - Pendant c/w 2- ½ npt. hub 3 - Pendant c/w 2- ¾ npt. hub 4 - Feed-thru c/w 2- ½ KO (VP Series only) (Ceiling / wall brackets & chain suspension kits shown in mounting options) (7) Labels: C - CSA (C/US) (8) Special Options EM1 - Emergency ballast, all areas, 700 lumen L - Lamps (energy saving except on HO) P - Prismatic polycarbonate lens PC - Polycarbonate catches S - Switch, on/off SSC - Stainless steel catches TSSC - Tamperproof stainless steel catches Notes: 1. Lamps are not included. 2. All emergency units have an integral test switch and charging circuit indicator lamp. 3. Consult factory for any catalog number or options not listed above for price and availability. Page 37

Ordering Guide, 120 Volt only Fixture Ballast No. of Raw Lumen Catalog Lamp Type Length Type Lamps Output Number F17T8 2 2,393 VPH2-2110C Two Foot Electronic FT40W/2G11 2 6,300 VPH2-2210C F32T8 2 6,962 VPH4-2110C Electronic Four FT40W/2G11 4 12,600 VPH4-4210C Foot F40/ES 2 4,770 VPH4-2410C Magnetic F48T12/HO 2 6,885 VPH4-2810C F32T8 4 13,924 VPH8-4110C Electronic Eight F96T8/HO 2 14,432 VPH8-2710C Foot F96T12/ES 2 10,010 VPH8-2310C Magnetic F96T12/HO 2 16,910 VPH8-2810C Notes: Catalog number shown is for hazardous area feed-thru design. (fixture is c/w two ½ npt. hubs). All models available in non-hazardous design, change VPH to VP. Certification Guide Magnetic ballast approved @ 40C ambient Electronic ballast approved @ 55C ambient Ballast Type No. of Lamps Class I Div. 2 Groups A, B, C & D Class I Zone 2 Groups IIA, IIB & IIC Class II Div. 2 Class III Approval T-Rating Approval T-Rating Approval Groups Electronic, 265mA, T8, RS 2 CSA T5 CSA T5 CSA F & G Electronic, 270mA, 2G11, RS 2 & 4 CSA T5 CSA T5 CSA F & G Magnetic, 430mA, T12, RS 2 CSA T5 CSA T5 CSA F & G Magnetic, 800mA, T12, HO 2 CSA T4A CSA T4 CSA F & G For detailed test results and approvals consult factory Page 38

Dimensions B A C Nominal Dimensions in Inches / Centimeters Cubic Size Weight Length A B C Feet / Meter lb. / kg 2 Foot All Models 25.8 / 65.6 5.0 / 12.7 7.0 / 17.78 1.26 / 0.0356 12.0 / 5.5 4 Foot RS T8/T12 Models 49.81 / 126.5 5.0 / 12.7 7.0 / 17.78 2.23 / 0.0631 20.3 / 9.2 4 Foot HO Models 49.81 / 126.5 5.4 / 13.72 7.0 / 17.78 2.23 / 0.0631 25.5 / 11.6 8 Foot All Models 97.81 / 248.4 5.4 / 13.72 7.0 / 17.78 4.17 / 0.1181 46.0 / 20.1 Weights shown are for magnetic ballasts Deduct 2 lb. / 0.91 kg. for electronic ballasts Bottom View (Two Foot Models) Drill Points (4) For Standard Direct Ceiling Mount 14.75 17.5 21.88 Bottom View (Four Foot Models) 1/4"-28 Brass Studs (2) Drill Point (2) For Optional Hub Entry 38.75 41.25 45.75 Bottom View (Eight Foot Models) Drill Points (8) For Standard Direct Ceiling Mount 5.125 13.75 86.75 89.25 93.75 3.375 Page 39

Mounting Options 8.25 0.3125 Dia. 38.75 C TO C 5.125 to 5.875 VP1091MTK Fixed ceiling / wall mounting kit. Consisting of 2 pairs of stainless steel brackets & hardware to mount brackets to fixture. 6.2 38.75 C TO C 7.0 to 7.4 6.2 VP1093MTK Fixed corner mounting kit. Consisting of 2 pairs of stainless steel brackets & hardware to mount brackets to fixture. 0.3125 Dia. 7.0 to 7.4 HP1095MTK Hazardous area pendant mounting kit. Consisting of 1 saddle strap and 1 universal junction box & pendant cover (¾ npt.) 41.5 C TO C Page 40

Parts List Item No. Part No. Description No Req d Item No. Part No. Description No Req d 1 008-4000 Lens, deep acrylic, for 4 ft., HO model 1 6 309-6851 Screw, socket mounting for 2G11 CF models 2 1* 008-8000 Lens, deep acrylic, for all 8 ft. models 1 7 380-1011 Mounting hardware, inner channel to housing 2 sets 1* 008-4100 Lens, shallow acrylic, 4 ft. model, except HO 1 8 758-0700 Socket, RDC, fixed for all HO models 2 or 4 1* 008-2100 Lens, shallow acrylic, for all 2 ft. models 1 8A 758-0701 Socket, RDC, spring loaded for all HO models 2 or 4 2 008-0400 Housing for all 4 ft. models 1 8B 754-8701 Socket, Bi-pin, for all T8 / T12 models 4 or 8 2* 008-0800 Housing for all 8 ft. models 1 8C 752-6050 Socket, 2G11 type, for all 2G11 CF models 2 or 4 2* 008-0200 Housing for all 2 ft. models 1 8* 752-5766 Support, lamp, for all 2G11 CF models 2 or 4 3 008-0148 Inner channel for 4 ft., HO model 1 8* 755-0314 Socket, single pin, fixed for F40T12, 8 ft. 2 3A 008-0144 Inner channel for 4 ft., T8 / T12 models 1 8* 755-0315 Socket, single pin, spring loaded for F40T12, 8 ft. 2 3B 008-0142 Inner channel for 4 ft., 2G11 CF model 1 9 008-0048 Radiator for all HO models 1 or 2 3* 008-0180 Inner channel for all 8 ft. models 1 10 380-0011 Mounting hardware for ballast to inner channel 2 or 4 sets 3* 008-0124 Inner channel for 2 ft., T8 models 1 11 380-1435 Grounding hardware assembly for all models 1 or 2 sets 3* 008-0122 Inner channel for 2 ft., 2G11 CF models 1 12 008-0601 Lens catches, standard Celcon type, all models 4, 6 or 12 4 008-0348 Channel cover / reflector, 4 ft., HO model ** 1 13 360-0500 Hub, standard ½ npt. all hazardous area models 2 4* 008-0344 Channel cover / reflector, 4 ft., except HO ** 1 14 350-0500 Plug, standard ½ npt. all hazardous area models 1 4* 008-0388 Channel cover / reflector, 8 ft. c/w 8 foot lamps 2 14* 008-0030 Plug, snap-in, ½ KO type, vapor proof models 2 4* 008-0324 Channel cover / reflector for all 2 ft. models 1 15 Ballast (See ballast chart page for type) 1 or 2 5 309-1003 Screw, channel cover mounting for all models 2 or 4 16 Lamps (See lamp chart page for type) 2 or 4 * Item not shown in drawing Page 41