CU-8R Installation Instructions

Similar documents
Area of Refuge Command Unit Installation Instructions Model AOR-24/AOR-32

Area of Rescue Command Unit Installation Instructions Model AOR-8 / Model AOR-16

WEBS-ZPS Zone Paging System Instructions

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA

BL-FLOWSTN-P FlowStation Module Installation Guide

Quick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1

ADDENDUM FOR 20, 27, & 28 OPTIONS

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Installation Instructions

StationPro II Network Manual rev. 06/27/2010

AMERICAN CHANGER & HOFFMAN MINT

Installing and Setting Up the Components

Installing Sentor. Hardware Installation

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

INSTALLATION INSTRUCTIONS

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Telephone Accessories

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

SERVICE MANUAL MODEL SSW-521-D2-ADA

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

Quick Start Guide. Mounting the Essential Plus and Elite

Digital Keypad Introduction

527F Dual PC Option Installation Guide as replacement for 32MP made by Fadal

Star Trac Fitness E-ST 5090 Stepper. Install Guide

Product Manual MNX10043 REV A MODEL DSB. Dual Sensor Modular Switch box

INSTALLATION INSTRUCTIONS

Tile Plow Installation O Connell

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

Megatouch FORCE Monitor Chassis Board Replacement

Connecting a Cisco Output Module

Power Supply (48Vdc, 2.5A)

YOU FOR CHOOSING UNITEC PARTS COMPANY UNITEC PARTS COMPANY

Assembly and Setup Manual

Quick Draw Electronics. Shooting Sports Timer User Manual. Model CLUB All In One

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Leased Line. NIONs. NCB Routers. Typical Application of NCB Routers

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

FITTING INSTRUCTIONS

EMC 10T "CE" Mechanical Upgrade Procedure

Ion Memory Upgrade. Visit the AMI Entertainment Web site PM

Installing a Power over Ethernet injector

GARDEN SPEAKERS GS4 INSTALLATION GUIDE RevA-GS4-SpkManual.indd 1

HUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide

E1135C PDU and Pod Upgrade Procedure

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Contents Copyright 2013 By Small Bear Electronics LLC

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)

INSTALLATION INSTRUCTIONS

Technical manual for two-family Kit Art. KAE5062

INTERCOM AMBULANCE/RESCUE VEHICLE MODEL ICA100 SURFACE MOUNT SERIES MODELS ICA200, ICA300 FLUSH MOUNT SERIES MODELS ICA400, ICA500

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

LMH-100 Installation Instructions

L-80 SERIES HOME & COMMERCIAL HIGH-TECH ENTERTAINMENT CENTER DIAGNOSTIC ADDENDUM

Rexroth Controller Installation & Operations Manual

FEATURES. AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Procedure to Replace a TCD DPM with an IS TCD DPM in a Maxum or Maxum II Analyzer

TracKing for Precedent Single Temperature and Multi-Temperature Installation Instructions

7403 K321. Display Wall Mount. Kit Instructions. Issue A

This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

C5 Series Stainless Steel Photoelectric

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

INTERCOM SYSTEM Model ICA900

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

The Packs Infotel. GSM Converter V2. Installation Manual V7

Copy Machine Reader. Installation and Setup Guide

SERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)

INSTRUCTION BULLETIN

Installing the DX LCD Display

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

2400 Series. Installation & Operations Manual. 42 Central Drive Farmingdale, NY

Energy Management System. Operation and Installation Manual

Thermometer / Barometer System

INSTALLATION GUIDE FOR IRRIGATION

Wiring Instructions v4

Galaxy Rectifier Shelf Field Replacement

Wiring Instructions. Gatekeeper h4.0. Technical Support.

Installing the ILC LightSync 4.3 or 7 Touch Screen Station. Rev. B

Installation Manual. for Mobile Link Adapter for Liquid-cooled Generators

Tile Plow Installation Gold Digger

Assembly and Setup Manual

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

ILC LightLEEDer MicroLite 1000P Retrofit Installation

BACnet Protocol Converter Kit for Use with Bacharach MultiZone Gas Monitors. Installation Manual

BACnet Protocol Converter Kit for Use with Bacharach MultiZone Gas Monitors. Installation Manual

Ethernet Setup Guide. Overview. Before you start. Tools and Equipment

Power-Style QED-2, Series 2 Low Voltage Switchboards

TOYOTA YARIS HATCHBACK Preparation

AC-500 XCEL DIRECT FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST

TABLE OF CONTENTS INTRODUCTION... 2

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

PACSystems* RX3i IC695ACC650

Installing the Cisco MDS 9020 Fabric Switch

Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2

Transcription:

CU-8R Installation Instructions I. Components Model CU-8R is shipped with the following components: QTY Item 1 Stainless Steel Enclosure 2 Lexan Panels 18 Nuts 1 Wall Mount Style Phone with RJ-11 Cable 1 EC-8 Consolidator 1 Strobe/Siren Assembly 1 Power Source / Uninterruptible Power Source (UPS) 2 Batteries 1 Wiring Harness 2 Low Voltage Relays 1 Door Handle Knob 1 Self-Adhesive Instruction Label 1 Installation and Operation Instruction Manual II. Assembly 1) Remove the five (5) screws holding the cover of the stainless steel enclosure in place. Carefully remove cover and place in a safe location for re-attachment later. Remove all loose components that are packed into the enclosure; you will install these in the following steps. 2) Mount enclosure in wall as described. NOTE: Openings are provided on bottom for providing power. Determine method of bringing power to enclosure before mounting enclosure in wall. 3) Mount the Strobe/Siren Assembly on wall in an appropriate location, per the instructions packed with the Strobe/Siren Assembly. 4) Complete self-adhesive instruction label by filling in the location of each rescue station in your system. Remove the label backing and place label well above the phone mounting studs in the handset compartment. 5) Plug one end of the RJ11 cable into the back of the telephone, routing the cable through the back of the phone as indicated on the phone. Mount telephone onto screw/studs in the accessible telephone section of the enclosure. Route the RJ-11 cable through the hole in the wall separating the two compartments and plug into the LOCAL PHONE Port on the EC-8 Consolidator. 6) Attach RJ11 connectors from Emergency Phone communication lines to ports 1-8 on EC-8 Consolidator. If a telephone or PBX line is to be used in addition to the phone in the enclosure, attach phone line to the TELCO IN Port on the EC-8. See attached drawing. 7) Remove the protective covering on the front and back of the two Lexan windows. Carefully place each window over the studs in the rear of the cover as shown. Secure with twenty (20) nuts (provided). 8) Connect 120VAC to the Power Source as indicated L N-GND (symbol). The green LED will illuminate. Talk-A-Phone Co. 7530 North Natchez Avenue Niles, Illinois 60714-3804 Rev. 12/19/12

9) Place the two batteries on the shelf inside the enclosure, below the power source. Connect the cable from the BAT terminal point on the power source to the two batteries (Red cable positive to the positive of one battery and Black cable negative to the negative of the other battery. The two batteries are connected in series via two quick disconnect terminals on either end of the cable). 10) Place cover over enclosure and re-secure with screws removed in step 1. III. Programming 1) Program EC-8 per Instructions packed with that unit. Be sure the EC-8 is set for LOCAL PHONE ONLY operation or LOCAL/TELCO alternation if an outside phone line or a PBX line is used in the system. 2) Program each Emergency Phone per Instructions packed with that phone. Be sure to program feature *78* in addition to any other features selected. NOTE: If no outside phone line or PBX line is used, program the number to be called as *13*5551234*. This is necessary for proper system function. Strobe/Siren Assembly Talk-A-Phone Co. 7530 North Natchez Avenue Niles, Illinois 60714-3804 Page 2 of 5

CU-8R Command Unit with Cover Talk-A-Phone Co. 7530 North Natchez Avenue Niles, Illinois 60714-3804 Page 3 of 5

CU-8R Command Unit Internal View Talk-A-Phone Co. 7530 North Natchez Avenue Niles, Illinois 60714-3804 Page 4 of 5

CU-8R Wire Harness Connections Talk-A-Phone Co. 7530 North Natchez Avenue Niles, Illinois 60714-3804 Page 5 of 5