MarCator. Digital and Dial Indicators MarCator. Dial and Digital Indicators Digital Indicators Overview 5-2 MarCator 175 R Standard versions with digital display 5-4 MarCator 186 R / 186 WR With tolerance function 5-6 MarCator 187 R With combined digital and analog display 5-1 MarCator 188 / 188 W With background lit display 5-12 MarCator 187 BR For 2-point inside measurement 5-14 Accessories for MarCator 186 R / 187 R / 188 5-15 Dial Indicators Overview 5-16 MarCator 83 A / 85 A / 83 S / 83 SW / 83 SB / 83 AZ Small Dial Indicators 5-18 MarCator 81 A / 81 AT / 81 S / 81 SW / 81 SB / 81 SM / 81 SRM / 81 AZ Standard versions 5-2 MarCator 81 AU / 81 AX / 81 SV / 81 AG Special versions 5-22 Contact Points and Accessories for Dial / Digital Indicators, Mechanical / Digital Comparators & Probes 5-24
- 5- overview Functions of Digital Indicators 175 R 175 R 175 R 186 R Catalog page 5-4 5-4 5-4 5-6 Measuring ranges mm / inch 12.5 /.5 12.5 /.5 12.5 /.5 12.5 /.5 IP51 IP51 IP51 25 / 1 5 / 2 1 / 4 Resolution metric.1 mm.5 mm.1 mm.1 mm inch.5.1.5.5 metric.1mm inch.5 Mounting shank 8h6 8h6 8h6 8h6 Protection class IP class acc. to IEC 6529 Functions: ON/OFF Set display to zero Switch between mm/inch Reversal of counting direction Enter numerical value - PRESET Data /REL-switchable Tolerance display Dynamic measuring functions MIN. MAX MAX MIN MAX-MIN (TIR) Search for reversal point START/STOP Factor can be set / adjusted Analog display Switch the analog value Key lock function LOC Data output USB Opto RS232C RS232C Control output:
5-186 ZR 186 WR 187 R 187 ZR 187 BR 188 188 W 5-6 5-9 5-1 5-1 5-14 5-12 5-12 12.5 /.5 12.5 /.5 12.5 /.5 12.5 /.5 12.5 /.5 12.5 /.5 25 / 1 25 / 1 25 / 1 25 / 1 25 / 1 5 / 2.1 mm.1 mm.1 mm.1 mm.1 mm.1 mm.1 mm.5.5.5.5.5.5.5.1mm.1mm.5.5 3/8 8h6 8h6 3/8 8h6 8h6 8h6
- 5- Digital Indicators 175 R IP52 Features Functions: ON/OFF RESET (Set display to zero) mm/inch Reversal of counting direction PRESET (for entering a numerical value) DATA (data transmission with a data connection cable) LOCK-Function: Individual buttons can be locked Auto-OFF (selectable) Immediate measurement due to the Reference system Operating time approx. 3 years (2 work. h/year) Max measuring speed 1.5 m/sec (6 /sec) MarConnect Data output: choose either USB OPTO RS232C High contrast Liquid Crystal Display with12 mm high digits Operating temperature 1-4 C Class of protection IP52 according to IEC 6529 Scope of supply: Battery, Operating instructions Reference System - Just set once to zero The new Digital Indicators 175 R are equipped with the innovative Reference-System. The zero position only has to be set one time: once it is set, the zero remains stored for all further measurements. Therefore, when the indicator is switched ON or the measuring spindle is moved the indicator is immediately ready for measurement; thus the need to reset as with a conventional indicator is now obsolete. Technical Data Measuring range Resolution Span of error G * Measuring force Weight mm (inch) mm/inch mm N g Order no. 12.5 (.5 ).1 /.5.2.5-1 18 43361 12.5 (.5 ).5 /.1.15.5-1 18 43362 12.5 (.5 ).1 /.5.5.5-1 18 43363 * in any zero point
5-5 Technical Data Accessories Order no. Battery 3V, Type CR 232 41252 Data Connection Cable USB (2 m) 16 EXu 412357 Data Connection Cable Opto RS232C (2 m), with SUB-D jack 9-pin 16 EXr 41241 Data Connection Cable (2 m), Flat plug 1-pin 16 EXd 412411 Additional Accessories Page Contact Points 91-913 5-24 Special Holder 941 5-25 Sensor Lever 943 5-25 Accessories for Data Processing see Chapter 11 Adapter Bush for adapting mounting shank 8h6 mm to inch bore.375 94 43113 Cable Release to raise the measuring spindle 951 4372 Lifter Protection Cap 186 a 433732 Lug Back, horizontal 175 Rbh 433641 Lug Back, vertical 175 Rbv 433642
- 5-6 MarCator 186 R The new Digital Indicator MarCator 186 R. With the large display and the integrated tolerance function, your measurement results are clearly visual. Clear display Tolerance indication with the diplayed value Displayed is the actual measured value and the tolerance zone position Tolerance indication without the value in the display. In and Out of tolerance will be indicated in the display as a symbol. Error free operation Lock function: This prevents unintentional activation of an operating button. Either all the operating buttons or only certain individual buttons can be locked. If a locked operating button is pressed the LOC symbol will appear in the display. Universal Data-Interface USB No interface box is required! Simple and inexpensive way to set up a multiple measuring instruments via a USB hub IP Protection class IP54 (optional) Protection cap is sealed Rubber bellows for the measuring spindle Sealed battery compartment RS232C To connect a compatible evaluation instrument Mahr Opto RS232C For direct connection to a COM port on a PC Code Initial IP International Protection First Numeral 5 Dust protected Second Numeral 4 Protection against splash water in all directions Absolute function: Digital Indicator can be set in any position to. without losing the reference to the preset value. Battery service life is 3 years Just set once to zero The new Reference system is extremely energy efficient as when the caliper is in standby mode; almost no power is required, thus extending the life of the battery up to 3 years. - System 2 Years Conventional 1 Year 2 Years 3 Years The new Digital Indicators 186 R are equipped with the innovative Reference-System. The zero position only has to be set one time: once it is set, the zero remains stored for all further measurements. Therefore, when the indicator is switched ON or the measuring spindle is moved the indicator is immediately ready for measurement; thus the need to reset as with a conventional indicator is now obsolete.
5-7 Digital Indicators MarCator 186 R / 186 ZR, Resolution.1 mm /.5 12,5 mm Dimensions 25 mm Measuring range a b c mm (inch) mm mm mm 12.5 (.5 ) 126.3 23 13.5 25 (1 ) 153.4 26.8 26.5 5 (2 ) 267.3 4 52 1 (4 ) 42.3 91 13 5 mm Features Functions: ON/OFF RESET (Set display to zero) mm/inch Reversal of the counting direction PRESET (Allows the entry of any value using set buttons) (Enter tolerance limit values) (Display can be set to zero, without losing the reference to the Preset value) <> (Tolerance GO / NO GO display mode) DATA (when connected with a data connection cable) Factor (adjustable) Immediate measurement due to the Reference system Individual buttons can be locked - Lock Function Operating and display unit (bezel) can be rotated 28 High contrast LCD with 11 mm high digits Operating time approx. 3 years (2 work. h/year) Maximum measuring speed 1.5 m/s (6 /s) Lifter protection cap on the measuring spindle MarConnect data output: choose either USB OPTO RS232C Operating temperature 1-4 C Class of protection IP42 in accordance to IEC 6529 Supplied with: Battery, operating instructions Technical Data Measuring Resolution Span of error* Repeatability Measuring Weight Mounting Order no. range force shank mm (inch) mm/inch mm mm N g dia. 12.5 (.5 ).1/.5.2.1.65 -.9 13 8h6 433713 25 (1 ).1/.5.2.1.65-1.15 14 8h6 4337131 5 (2 ).1/.5.2.1 1.25-2.7 19 8h6 4337132 1 (4 ).1/.5.2.1 1.6-3.5 235 8h6 4337133 12.5 (.5 ).1/.5.2.1.65 -.9 15 3/8 4337155 25 (1 ).1/.5.2.1.65-1.15 16 3/8 4337156 * in any zero point
- 5-8 Digital Indicators MarCator 186 R / 186 ZR, Resolution.1 mm /.5 Dimensions 25 mm Measuring range a b c mm (inch) mm mm mm 12.5 (.5 ) 126.3 23 13.5 25 (1 ) 153.4 26.8 26.5 5 (2 ) 267.3 4 52 1 (4 ) 42.3 91 13 5 mm Features Functions: ON/OFF RESET (Set display to zero) mm/inch Reversal of the counting direction PRESET (Allows the entry of any value using set buttons) (Enter tolerance limit values) (Display can be set to zero, without losing the reference to the Preset value) <> (Tolerance GO / NO GO display mode) DATA (when connected with a data connection cable) Factor (adjustable) Immediate measurement due to the Reference system Individual buttons can be locked - Lock Function Operating and display unit (bezel) can be rotated 28 High contrast LCD with 11 mm high digits Operating time approx. 3 years (2 work. h/year) Maximum measuring speed 1.5 m/s (6 /s) Lifter protection cap on the measuring spindle MarConnect data output: choose either USB OPTO RS232C Operating temperature 1-4 C Class of protection IP42 in accordance to IEC 6529 Supplied with: Battery, operating instructions Technical Data Measuring Resolution Span of error* Repeatability Measuring Weight Mounting Order no. range force shank mm (inch) mm/inch mm mm N g dia. 12.5 (.5 ).1/.5.5.2.65 -.9 13 8h6 433712 25 (1 ).1/.5.5.2.65-1.15 14 8h6 4337121 5 (2 ).1/.5.8.2 1.25-2.7 19 8h6 4337122 1 (4 ).1/.5.9.2 1.6-3.5 235 8h6 4337123 12.5 (.5 ).1/.5.5.2.65 -.9 15 3/8 433715 25 (1 ).1/.5.5.2.65-1.15 16 3/8 4337151 * in any zero point
5-9 Digital Indicators MarCator 186 W, Waterproof version 12,5 mm Dimensions 25 mm Measuring range a b c mm (inch) mm mm mm 12.5 (.5 ) 144.3 23 28.6 25 (1 ) 193.2 26.8 5 Features Functions: ON/OFF RESET (Set display to zero) mm/inch Reversal of the counting direction PRESET (Allows the entry of any value using set buttons) (Enter tolerance limit values) (Display can be set to zero, without losing the reference to the Preset value) <> (Tolerance GO / NO GO display mode) DATA (when connected with a data connection cable) Factor (adjustable) Immediate measurement due to the Reference system Individual buttons can be locked - Lock Function Operating and display unit (bezel) can be rotated 28 High contrast LCD with 11 mm high digits Operating time approx. 3 years (2 work. h/year) Maximum measuring speed 1.5 m/s (6 /s) Sealed protection cap Measuring spindle is sealed with a rubber bellows, thus preventing contamination by liquids and impurities MarConnect data output: choose either USB OPTO RS232C Operating temperature 1-4 C Class of protection IP54 in accordance to IEC 6529 Supplied with: Battery, operating instructions Technical Data Measuring Resolution Span of error* Repeatability Measuring Weight Order no. range force mm (inch) mm/inch mm mm N g 12.5 (.5 ).1/.5.5.2.65-1.4 135 433714 25 (1 ).1/.5.5.2 1. - 2.25 145 4337141 12.5 (.5 ).1/.5.2.1.65-1.4 135 4337145 25 (1 ).1/.5.2.1 1. - 2.25 145 4337146 * in any zero point
- 5-1 MarCator 187 R The new Digital Indicator MarCator 187 R. The multi-functional Digital Indicator with a combined analog and digital display as well as tolerance and dynamic measuring functions. Dynamic measuring functions MAX-MIN-Function ideal for testing flatness and concentricity MAX and / or MIN for searching the reversal point MAX MIN Universal Data-Interface USB No interface box is required! Simple and inexpensive way to set up a multiple measuring instruments via a USB hub To connect a compatible evaluation instrument Clear display Tolerance indication The integrated bar graph visualizes the tolerance deviation. The out of tolerance; whether above the upper or below the lower tolerance limit is represented by arrows shown in the display. RS232C Mahr Opto RS232C For direct connection to a COM port on a PC Absolute function: Digital Indicator can be set in any position to. without losing the reference to the preset value. Just set once to zero Battery service life is 3 years The new Digital Indicators 187 R are equipped with the innovative Reference-System. The zero position only has to be set one time: once it is set, the zero remains stored for all further measurements. Therefore, when the indicator is switched ON or the measuring spindle is moved the indicator is immediately ready for measurement; thus the need to reset as with a conventional indicator is now obsolete. The new Reference system is extremely energy efficient as when the caliper is in standby mode; almost no power is required, thus extending the life of the battery up to 3 years. - System 2 Years Konventionell 1 Year 2 Years 3 Years Error free operation Lock function: This prevents unintentional activation of an operating button. Either all the operating buttons or only certain individual buttons can be locked. If a locked operating button is pressed the LOC symbol will appear in the display.
5-11 Digital Indicators MarCator 187 R / 187 ZR, with analog display Dimensions MAX MIN 12,5 mm Measuring range a b c mm (inch) mm mm mm 12.5 (.5 ) 126.3 23 13.5 25 (1 ) 153.4 26.8 26.5 Analog display Readings mm / inch 25 mm Display range mm / inch.1 /.5 ±.2 / ±.1.2 /.1 ±.4 / ±.2.4 /.5 ±.8 / ±.1.1 /.1 ±.2 / ±.2 Features Functions: ON/OFF RESET (Set display to zero) mm/inch Reversal of the counting direction PRESET (Allows the entry of any value using set buttons) (Enter tolerance limit values) Tolerance band max. 1.6 mm MAX/MIN memory, ideal for searching the reversal point TIR (MAX-MIN) ideal for testing concentricity and flatness (Display can be set to zero, without losing the reference to the Preset value) (Set analog display to zero) DATA (when connected with a data connection cable) Factor (adjustable) Immediate measurement due to the Reference system Individual buttons can be locked - Lock Function Operating and display unit (bezel) can be rotated 28 High contrast LCD with 8.5 mm high digits Operating time approx. 3 years (2 work. h/year) Maximum measuring speed 1.5 m/s (6 /s) MarConnect data output: choose either USB OPTO RS232C Operating temperature 1-4 C Class of protection IP42 in accordance to IEC 6529 Supplied with: Battery, operating instructions Technical Data Measuring Resolution Span of error* Repeatability Measuring Weight Mounting Order no. range force shank mm (inch) mm/inch mm mm N g dia. 12.5 (.5 ).1/.5.5.2.65 -.9 14 8h6 433716 25 (1 ).1/.5.5.2.65-1.15 15 8h6 4337161 12.5 (.5 ).1/.5.5.2.65 -.9 15 3/8 433717 25 (1 ).1/.5.5.2.65-1.15 16 3/8 4337171 * in any zero point
- 5-12 MarCator 188 The new Digital Indicator MarCator 188. Tolerance monitoring is simplified with the changing of the color in the background lit display. D y n a m i c m e a s u r i n g f u n c t i o n s MAX-MIN memory: ideal for testing flatness and concentricity MAX-MIN memory: for searching the reversal point MAX MIN Universal Data-Interface USB No interface box is required! Simple and inexpensive way to set up a multiple measuring instruments via a USB hub To connect a compatible evaluation instrument Tolerance function: clearly visual tolerance excess due to the change of color in the background lit display. RS232C Mahr Opto RS232C For direct connection to a COM port on a PC Control output can be connected to a SPS Absolute function: Digital Indicator can be set in any position to. without losing the reference to the preset value. Protection class IP54 according to IEC 6529. Especially suited for use in a manufacturing environment (excludes measuring range 5 mm) Analog display 3.I 3 Code Initial IP International Protection First Numeral 5 Dust protected Second Numeral 4 Protection against splash water in all directions Readings (switchable) mm / inch mm Display range mm / inch.1 /.5 ±.3 / ±.15.2 /.1 ±.6 / ±.3.5 /.5 ±.15 / ±.15.1 /.1 ±.3 / ±.3
5-13 Digital Indicators MarCator 188 / 188 W, with analog display MAX MIN 12,5 mm 25 mm 5 mm Features Functions: ON/OFF RESET (set digital and analog displays to zero) - - (set the analog display to zero) PRESET (enter any numerical values) DATA (data transmission) mm/inch-switchable Reversal of counting direction (switch value in digital display) MAX-MIN memory, ideal for searching the reversal point MAX-MIN memory, e.g. for testing flatness and concentricity (Enter tolerance limit values) Tolerance band max. 1.6 mm LOCK: operating functions can be blocked via PC-Software Power supply via the main power adapter MarConnect data output: USB, OPTO RS232C, or Can be remotely operated via the interface (Opto RS232C) Control output compatible to Dial Comparators with limit contacts Operating and display unit (bezel) can be rotated 28 Class of protection IP54 in accordance to IEC 6529 Operating temperature 5-4 C High contrast backlit LCD with 6.5 mm high digits Analog display with 4 mm pointer ensures better visual recognition, ideal when checking concentricity or flatness as well as searching for the reversal point when measuring bores Supplied with: Mains adapter, rubber bellows, operating instructions Technical Data Measuring range Resolution Measuring force Span of error* Protection class mm (inch) mm/inch N mm Order no. 23 V Order no. 115 V 12.5 (.5 ).1 /.5.65-1.4.5 IP54 4337 43371 25 (1 ).1 /.5 1. - 2.25.5 IP54 43371 433711 5 (2 ).1 /.5 1.25-2.7.8 IP42 43372 433712 * in any zero point
- 5-14 Digital Indicator MarCator 187 BR for 2 point inside measurement MAX MIN Dimensions 12,5 mm Measuring range a b c mm (inch) mm mm mm 12.5 (.5 ) 131 23 13.5 Example of application With a 2 point inside measuring instrument the point of reversal is automatically determined through rocking back and forth. The actual value is detected and stored by the MIN function and indicated in the display (3). Analog display Readings mm / inch Features Functions: ON/OFF RESET (Set the display to zero) mm/inch Reversal of the counting direction PRESET (Allows the entry of any value using set buttons) (Enter tolerance limit values) Tolerance band max. 1.6 mm START/STOP for searching the reversal point MAX/MIN memory, ideal for searching the reversal point (Display can be set to zero, without losing the reference to the Preset value) (Set analog display to zero) DATA (when connected with a data connection cable) Factor (adjustable) Immediate measurement due to the Reference system Individual buttons can be locked - Lock Function Operating and display unit (bezel) can be rotated 28 High contrast LCD with 8.5 mm high digits Operating time approx. 3 years (2 work. h/year) Maximum measuring speed 1.5 m/s (6 /s) Sealed protection cap MarConnect data output: choose USB, OPTO RS232C, Operating temperature 1-4 C Class of protection IP42 in accordance to IEC 6529 Supplied with: Battery, operating instructions Display range mm / inch.1 /.5 ±.2 / ±.1.2 /.1 ±.4 / ±.2.4 /.5 ±.8 / ±.1.1 /.1 ±.2 / ±.2 Technical Data Measuring Resolution Span of error* Repeatability Measuring Weight Mounting Order no. range force shank mm (inch) mm/inch mm mm N g dia. 12.5 (.5 ).1/.5.5.2.65 -.9 14 8h6 4337162 * in any zero point
5-15 Accessories for MarCator 186 R, 187 R und 188 Accessories for MarCator 186 R and 187 R Order no. Battery 3V, Type CR 245 884464 Data Connection Cable USB (2 m) 16 EXu 412357 Data Connection Cable Opto RS232C (2 m), with SUB-D jack 9-pin 16 EXr 41241 Data Connection Cable (2 m), Flat plug 1-pin 16 EXd 412411 Mounting Lug 186 b 4337421 Rubber bellows for 186 W - 12.5 mm 4337472 Rubber bellows for 186 W - 25 mm 4337474 Accessories for MarCator 188 Order no. Data Connection Cable USB (2 m) 2 usb 434623 Data Connection Cable Opto RS232C (2 m), with SUB-D jack 9-pin 2 r 43462 Data Connection Cable (2 m), Flat plug 1-pin 2 d 434621 Cable to connect control output to an SPS sps 434631 Mounting Lug 185 b 631 Rubber bellows for 188 W - 12.5 mm 4337472 Rubber bellows for 188 W - 25 mm 4337474 Control Instrument for remote control 2 sg 434635 operation 185 a 182 p (12,5/25) Accessories for MarCator 186 R, 187 R and 188 Order no. Cable Release for measuring ranges 12.5 and 25 mm 185 a 4336311 Pneumatic Lifter for measuring ranges 12.5 and 25 mm 182 p 4336237 Pneumatic Lifter for measuring ranges 5 and 1 mm 182 p 433623 Additional Accessories Page Contact Points 91-913 5-24 Special Holder 941 5-25 Sensor Lever 943 5-25 182 p (5/1) Accessories for Data Processing see Chapter 11
l l l - 5-24 MarCator. Dial Indicators Contact Points and Accessories for Dial Indicators, Dial Comparators and Probes Standard Contact Points 91 Ball dia. 3 mm 91 92 93 Catalog no. order no. 91 with steel ball 4361 91 H with carbide ball 4362 91 R with ruby ball 4363 Spherical Contact Points 92 Flat Contact Points 93 6 5 R 1,5 ø4,2 R 6 ø4,2 ø4 ø4,2 92 92 H 93 93 H Steel Carbide Steel Carbide contact face tipped Length Order no. Order no. Order no. Order no. mm 4 4367 67 6 4369 671 43611 3 8 4361 4364 43672 43612 R,3 1 43611 43641 43673 43613 ø4 12 43612 43642 43674 43614 15 43613 43643 43675 43615 2 43614 43644 43676 43616 97 98 H 25 43615 43645 43677 43617 3 43616 43646 4363 43611 35 43617 43647 43678 43618 4 43619 43649 43631 436111 45 43626 4365 43633 5 43618 43648 43679 43619 ø11,3 ø12 55 43631 65 43635 75 4362 85 43636 95 43629 Special Contact Points 5 5 1 94 R3 5 1 5 95 96 H R,3 ø4 5 913 3 ENt 426 M d 4 1 (,5) ø7,5 ø7,5 Ball Contact Point 96 H with carbide ball. accuracy ball dia. /-6µm Ball dia. d l order no. Ball dia. d l Order no. mm mm mm mm 1 8.5 43615 5.5 9 436161 1.25 8.5 436151 6 9 436162 1.5 8.5 436152 6.35 (1/4 ) 9 436163 1.75 8.5 436153 6.5 1 436164 2 8.5 436154 7 1 436165 2.5 8.5 436155 7.5 11 436166 3 8.5 436156 8 11 436167 3.5 8.5 436157 8.5 12 436168 4 8.5 436158 9 12 436169 4.5 8.5 436159 1 13 43617 5 9 43616 Contact Rollers 99 Concentricity error 3 µm 99 A 18 order no. Conical Contact Points, Steel 9 613 Carbide tipped 94 H 436131 Wedge Shaped Contact Points, Steel 95 614 Carbide tipped 95 H 436141 Flat Contact Points, Steel, A = 1 cm 2 97 4362 Carbide tipped, dia. 7 mm 97 H 43621 Spherical Contact Points, Steel 98 621 Carbide tipped 98 H 436211 Flat Contact Point, for mounting Pin Gage Holder 426 M for measuring threads using three-wire method 913 4364 Disc Type anvil thickness.5 mm, hardened 3 ENt 412631 Disc Type anvil thickness 1 mm, hardened 3 ENt 488222 order no. Cylindrical Roller 99 A 43622 Radiused Roller, R = 5 mm 99 B 436221 4 1
13 5-25 l MarCator. Dial Indicators Contact Points and Accessories for Dial Indicators, Dial Comparators and Probes Measuring Attachment 91 H order no. with parallel adjustable carbide blades 91 H 623 Pin Contact Point 911 dia. 1.5 mm, flat Length l order no. Length l Order no. mm mm 15 43628 35 436284 2 436281 4 436285 25 436282 5 436286 3 436283 912 Pin Contact Point 911 H order no. Carbide tipped, dia 1 mm, flat 911 H1 624 Carbide tipped, dia 1.5 mm, flat 911 H 6241 Measuring Spindle Extensions 912 Length l Order no. Length l Order no. mm mm 1 43625 35 436254 15 436251 5 436255 2 436252 75 436256 25 436253 1 436257 941 G ø8h7 941 W 8H7 2 Special Holder 941 For all types of measuring equipment For placing a dial indicator at a certain distance or angle Travel of the measuring spindle 3 mm Contact Point 91 (interchangeable) 13 l 1 47 6 ø12 ø8h6 ø4 l 1 l 2 4 8h6 Straight Holder 941 G Angular Holder 941 w Mounting shank length l 1 Order no. Order no. l 2 Order no. l 2 Order no. l 2 mm Angle α=45 mm Angle α=6 mm Angle α=9 mm } } } 25 4365 43651 652 653 5 43651 436511 53.7 436521 49.3 436531 34.5 75 43652 43651 65 6532 Transmission error with the 941 W max. 1%; for travel 3 mm =.3 mm Sensor Level 943 order no. 943 ø8h7 For testing concentricity in bore holes as well as difficult to reach outside diameters To be inserted in a measuring stand with a lifting device Contact Point 91 interchangeable Travel ±1 mm 4367 11 45 5 94 ø1 ø12 12 4 6 ø8h6