Double-channel measuring and control instrument for free chlorine and ph-value - additionaly ORP optional

Similar documents
Neon pr. ph/ ORP measurement. Applications. Description

Control and automatic dosing

Sensor for car parks and tunnels

MID approval no. DE-08-MI004-PTB004 Date of release

world class water monitoring series 42

LDCL DIGITAL CONTROLLER OPERATING MANUAL

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Process Indicator Controller (Digital) (Product code 3.1 to 3.15)

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

Neon EC Neon EC IL CLEAR. CONTROL. CONNECT.

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

SX90 Process Controller

Technical specification Marine Master Clock

Transmitter / Controller Series J dtrans ph 01, Rd 01, Lf 01, Rw 01, Az 01

Neon DIS Krypton DIS CLEAR. CONTROL. CONNECT.

Process displays For current and voltage

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

DISOMAT T Weigh Transmitter

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

EL300. Multi-Channel Water Controller. Specialist Of UV Spectroscopy

LD MULTICHANNEL - LD MULTICHANNEL PLUS

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

*suitable both for membrane sensors or chlorine open cell

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

for measuring ph values and redox potential, conductivity and dissolved oxygen Content

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Pen Drive USB Datalogger!

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

Displays Transducers. Displays and transducers

Electronic SD1, AS 8, ASR 14, ASR 20

DMT345 and DMT346 Dewpoint Transmitters

Indicators. Product Mounting Display Height Page

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Product data sheet accessories control and regulation Accessories AIRWIN

Faults on the system Proximity switch connection technology:

Power Meter PowerMonitor 500

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

7110 MTF-FG. Transmitter for Turbidity and Solids Content ISO Technical Information TI 232e

CERTIFICATE of EU TYPE-APPROVAL

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Millenium II +: general characteristics

Stratos Pro A4 PH. Connection

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

Weighing Indicator. Features. Description. Applications

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II

InBin-P Pressure switches from 5 Pa Pa

Presented By. NicolScales.com Contact Us

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

How to build a Conductivity Measurement System

LDCL DIGITAL CONTROLLER O P E R A T I N G M A N U A L

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)

Electronic Temperature Controller. Instruction Manual Version

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

iologik 4000 Series (M) Modules

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

SINGLE-CHANNEL PROCESS INDICATOR series 8001

Electrochemistry Meters. Series SD (IP 67 waterproof) Electrochemistry Meters

N420 R420 R423. series

Gas Controller System DGC-06

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

PXR Series Advanced Self-Tuning Temperature and Process Controllers

Easy To Use OEMS Take Note

Flow simulation system PROline FieldCheck

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line

DIGITAL INDICATING CONTROLLER

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

BASE LOAD UNLOAD 3 PRODUCTS 6 PRODUCTS 14 PRODUCTS Multiprogram

EngyVolt RV12 and RV15

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

InCos-P Pressure sensor 20 Pa Pa

iothinx 4500 Series (45MR) Modules

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters

HOBO Motor On/Off Data Logger (UX90-004x) Manual

Signet ph/orp Transmitter * *

PTU300 Combined Pressure, Humidity and Temperature Transmitter

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

LBVR1718. Description. Features channel paperless recorder

DTM Distributed Transmitter Monitor

Transcription:

Double measurement of free chlorine and ph -optionally with additional ORP measurement Easy and safe operation by plain text menu guidance Log book function Graphical trend display of the last 3 h applications Drinking Water / Beverages Waste Water Treatment Disinfection description The dialog W 2 CL2 PR R is a sophisticated instrument for the precise measurement and control of the chlorine concentration and the ph-value - additionally an ORP measurement is optional. It is available in a wall mounted housing.

particular characteristics Variable assignment of relay and current outputs 2 limit values with delay Dosage check Semi-automatic two point-calibration for ph Slope and zero point monitoring for ph Automatic or manual ph-value compensation for ph Serial interface RS 485 2 or 3 scaleable, galvanically isolated 0/4.. 20 ma outputs 2 separate PID-controller Real time clock Background illuminated two-line LC-Display Password function information Measuring and control instruments of the dialog series are also available for 117 VAC and 24 VDC (only wall mounted housing) - wihtout additional charge.

technical data measuring parameter free Chlorine ph-value ORP input characteristics accuracy temperature measuring range temperature coefficient conditions 0.. 4.00 mg/l 0.. 20.00 mg/l 0.. 14.00 ph -1500.. +1500 mv 1 % mg/l Cl2 of range, +/- 0,01 ph, +/- 1 mv -30.. +140 C non-linear min. flow 10 l/h recommended: 30 l/h ph-range 6.0.. 8.0 ph output characteristics output signal 3 0/4.. 20 ma (scaleable, galvanically isolated) load max. 500 Ohm registration range Free scaleable within the measuring range voltage output +/- 6 VDC for impedance converter serial interface RS 485 Baud rate 9600 data format 8 bit power supply line voltage power consumption ambient conditions ambient temperature relative humidity protection class 24 / 117 / 230 VAC, +6 / -10 %, 40.. 60 Hz optional: 24 VDC 10 VA operation 0.. +50 C, storage -20.. +65 C max. 90% rh at 40 C (non-condensing) wall mounted housing IP 65 controller control response On/off controller (adjustable hysteresis) P/PI/PID-controller (pulse-pause, pulse-frequency or continous controller output) relays 3 relays, each with potential-free CO contact, max. 250 V, 6 A, 550 VA onset delay 0.. 200 sec till controller active digital input Controller stop via external contact

certificates and approvals CE-symbol Declaration of conformity: The product meets the requirements of the harmonized European standards. It thus complies with the legal requirements of the EC directives. The manufacturer confirms successful testing of the product by affixing the CE symbol. mechanical construction - wall mounted housing material ABS dimensions 165x160x85 mm weight 1.25 kg connection Spring-loaded terminals order information name description article number dialog W 2 CL2/ PR R dialog W 2 CL2/ PR R 20 mg wall mounted housing, 230 VAC, 0.. 4 mg/l 115212K wall mounted housing, 230 VAC, 0.. 20 mg/l 115230K

accessories accessories CHECKIT Comparator The CHECKIT Comparator is a compact handy colorimeter unit which is suitable for both mobile and static analysis work. CHECKIT Comparator is a colorimetric rapid test for easy determination of Free Chlorine, Total Chlorine, Chlorine Dioxide or Ozone concentrations that can be used as an indication measurement for our amperometric measuring systems. Naturally, regarding resolution and accuracy, the rapid test does not come close to the Krypton systems, and it cannot replace a fotometric measurement. However, it provides a quick orientation and can therefore prove helpful during installation or routine comparison. The CHECKIT Comparator comes in a robust plastic casing with all necessary equipment. PKV 30-DPS Converter for PROFIBUS-DP for max. 32 instruments of the K 100 oder dialog series. Converting of RS 485 to PROFIBUS-DP interface, instrument in a housing for installation on a top hat trail, dimension 105 X 105 x 80 mm (HxBxT), connectioncable inclusive S-341 data logger The bus data logger S-341 on the base of the RS-485 with Kuntze protocol reads, shows, and stores measuring data of up to 10 Kuntze instruments with up to 8 parameters each.