Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signals wire:... 0 ma wire: 0... 0 V others on request Special characteristics diameter 5 mm cable and sensor section separable excellent accuracy communication connection thermal error in compensated range 0... 70 C: 0. % FSO TC 0.0 % FSO / 0K TurnDown :0 Optional versions ISversion zone 0 cable protection via corrugated pipe mounting accessories as cable gland and terminal clamp in stainless steel different kinds of cables different kinds of seal materials The separable precision stainless steel probe is designed for continuous fill level and level measurement of water and liquid mediums. The signal processing of sensor signal is done by digital electronics with 6bit analogue digital converter. Consequently it is possible to conduct an active compensation of sensor intrinsic deviations from normal conditions like nonlinearity and thermal error. In order to facilitate stockkeeping and maintenance the transmitter body is plugged to the cable assembly with a connector and can be changed easily. Preferred areas of use are Water / filtrated sewage ground water level measurement level measurement in wells and open waters rain spillway basin level measurement in container water treatment plants water recycling BD SENSORS GmbH BDSensorsStraße Tel: +9 (0) 9 5 / 98 0 www.bdsensors.com D 9599 Thierstein Fax: +9 (0) 9 5 / 98 info@bdsensors.de
Technical Data Input pressure range Nominal pressure gauge [bar] 0.0 0 0 Level [mh O] 0 0 0 00 00 Overpressure [bar] 5 0 0 0 80 Burst pressure [bar] 7.5 5 5 50 0 On request we adjust the device within the turndownpossibility by software on the required pressure range. Output signal / Supply Standard wire:... 0 ma / V S =... 6 V DC with RS communication interface Option ISprotection wire:... 0 ma / V S =... 8 V DC Options wire: 0... 0 V / V S =... 6 V DC Performance Accuracy Performance after turndown (TD) TD :5 TD > :5 Permissible load IEC 60770 : ± 0. % FSO no change of accuracy formula for accuracy calculating (for nominal pressure gauge 0.0 bar see note ): ± [0. + 0.05 x turndown] % FSO with turndown = nominal pressure range / adjusted range e.g. following accuracy can be calculated for turndown :0: ± (0. + 0.05 x 0) % FSO i.e. the accuracy is ± 0.5 % FSO current wire: R max = [(V S V S min ) / 0.0 A] voltage wire: R min = 0 k Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / k Long term stability ± (0. x turndown) % FSO / year at reference conditions Response time ca. 00 msec Adjustability following parameters can be adjusted (interface / software needed ) electronic damping: 0... 00 sec offset: 0... 90 % FSO turndown of span: max. :0 accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) nominal pressure gauges 0,0 bar are excluded; for these the calculation of accuracy is as follows: ± (0. + 0.0 x turndown) % FSO e.g. torndown :: ± (0. + 0.0 x ) % FSO i.e. the accuracy is ± 0.6 % FSO software, interface and cable must separate be ordered (software is compatible with Windows 95, 98, 000, NT from version.0 or higher and XP) Thermal effects (Offset and Span) Tolerance band [% FSO] ± (0. x turndown) in compensated range 0... 70 C TC [% FSO / 0 K] ± (0. x turndown) in compensated range 0... 70 C Permissible temperatures medium: 0... 70 C storage: 5... 70 C electronics / environment: 5... 65 C Electrical protection 5 Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 5 additional external overvoltage protection unit in terminal box KL or KL with atmospheric pressure reference available on request Cable with sheath material 6 PVC (5 70 C) grey PUR (0 70 C) black FEP 7 (0 70 C) black others on request 6 cable with integrated air tube for atmospheric pressure reference 7 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expected Materials (media wetted) Housing stainless steel.0 (6L) Seals FKM, EPDM, others on request Diaphragm stainless steel.5 (6L) Protection cap POM Explosion protection (only for... 0 ma / wire) Approvals DX9LMP 08 i IBExU 0 ATEX 068 X / IECEx IBE.007X zone 0: II G Ex ia IIC T Ga zone 0: II D Ex ia IIIC T 85 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 H, the supply connections have an inner capacity of max. 7 nf to the housing Ambient temperature range in zone 0: 0... 60 C with p atm 0.8 bar up to. bar in zone or higher: 0... 65 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Current consumption max. 5 ma Weight approx. 50 g (without cable) Ingress protection IP 68 CEconformity EMC Directive: 0/0/EU ATEX Directive 0//EU pressure and level
Technical Data Wiring diagram / connector wiresystem (current) wiresystem (voltage) Binder series 7 8 (5pin) supply + supply + p p VS Binder series 7 8 (7pin) VS supply I supply U signal + V Pin configuration Supply + Supply Signal + (for wire) RxD TxD GND Binder series 7 8 (5pin) / wire Binder series 7 8 (5pin) / wire Binder series 7 8 (7pin) / wire with communication interface / wh (white) / bn (brown) (6) / gn (green) / ye (yellow) 5 / gr (grey) 7 / gn (green) cable colours (IEC 60757) wh (white) bn (brown) gn (green) Shield 5 5 / gnye (greenyellow) gnye (greenyellow) 8 in separated version Dimensions (in mm) standard option separated version version with corrugated pipe www.bdsensors.com
Technical Accessories Data Mounting flange with cable gland Technical data Suitable for all probes Flange material stainless steel.0 (6L) Material of standard: brass, nickel plated cable gland on request: stainless steel.05 (0); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / PN0 D = 5, k = 85, b = 8, n =, d=. kg DN50 / PN0 D = 65, k = 5, b = 0, n =, d= 8. kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= 8.8 kg Ordering type Ordering code DN5 / PN0 with cable gland brass, nickel plated ZMF50 DN50 / PN0 with cable gland brass, nickel plated DN80 / PN6 with cable gland brass, nickel plated Terminal clamp Technical data Suitable for all probes with cable 5.5... 0.5 mm Material standard: steel, zinc plated optionally: stainless steel.0 (0) Weight approx. 60 g Ordering type Terminal clamp, steel, zinc plated Terminal clamp, stainless steel.0 (0) Display program ZMF500 ZMF806 Ordering code Z0058 Z0057 CIT 00 Process display with LED display CIT 50 Process display with LED display and contacts CIT 00 Process display with LED display, contacts and analogue output CIT 50 Process display with LED display, bargraph, contacts and analogue output CIT 00 Process display with LED display, contacts, analogue output and Exapproval CIT 600 Multichannel process display with graphicscapable LC display CIT 650 Multichannel process display with graphicscapable LC display and datalogger CIT 700 Multichannel process display with graphicscapable TFT monitor, touchscreen and contacts PA 0 Field display with digit LC display For further information please contact our sales department or visit our homepage: http://www.bdsensors.com cable gland M6x.5 with seal insert (for cable... mm) 08 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. pressure Tel and +9 level (0) 9 5 / 98 0 www.bdsensors.com Fax +9 (0) 9 5 / 98 info@bdsensors.de LMP08 i_d_8
Ordering code Pressure 0 Input [mh O] [bar].0 0.0 0 0 0 0.0 0 0 0.0 0 0 0.0 0 0 00 0 0 0 00 0 0 0 cable with integrated air tube for atmospheric pressure reference available on request: calibration of individual pressure range higher than 00 mbar with accuracy 0. % software, interface and cable have to be order separately (ordering code: CISG; software appropriate for Windows 95, 98, 000, NT Version.0 or newer and XP) stainless steel pipe is not part of the supply in bar in mh O 9 9 9 Housing stainless steel.0 (6L) Diaphragm stainless steel.5 (6L) Output 0 ma / wire intrinsic safety 0 ma / wire 0 0 V / wire E Seals FKM EPDM PVCcable PURcable FEPcable Accuracy 0. % FSO Cable length in m 9 9 Version standard with communicaton interface prepared for mounting with stainless steel pipe 6 consult cable protection with stainless steel corrugated pipe 9 9 with pipe length in m 9 9 Windows is a registrated trademark of Microsoft Corporation 0.06.0 0 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.