FIT 7A. Digital load cell dynamic weighing. Special features. Data sheet
|
|
- Sherman Fitzgerald
- 6 years ago
- Views:
Transcription
1 FIT 7A Digital load cell dynamic weighing Special features - Accuracy class up to C4 and maximum scale interval factor Y up to 25,000 with OIML R60 test report - Off-center load compensated (OIML R76) - Dosing mode - 4 limit value switches - Trigger mode (external or level) - Automatic parameterization for dynamic applications - Stainless steel - Degree of protection IP66 - Integral overload protection - PC software for parameter setup and dynamic analysis - arious options and accessories are available Dimensions (in mm; 1 mm = inches) Data sheet M6 7mm deep 25± ± ± ± ±0.2 6 H7 8mm deep
2 Specifications Accuracy class 1) FIT7A Number of load cell verification intervals n LC 3000 Fraction P lc 0.8 Maximum capacity E max kg Minimum load cell verification interval (standard and option 6 = A) Maximum scale interval factor Y (standard and option 6 = A) Temperature coefficient of the zero signal per 10 K (standard and option 6 = A) v min g Y , , TC 0 % of C n Maximum platform size (L x W) mm 400 x x 500 Nominal (rated) sensitivity C n digit 1,000,000 Zero signal 0 100,000 Temperature coefficient of the sensitivity per 10 K 3) in the temperature range C TC S C % of Non linearity 3) d lin C n Relative reversibility error 3) d hy Minimum dead load output return MDLOR Off load error 2) C Nominal (rated) ambient temperature range B T Operating temperature range B tu C Storage temperature range B tl Limit load at 20 mm eccentricity E L 1000 Service load at centric load input % of 150 Relative vibrational stress at max. 50 mm E max F eccentricity srel 70 Nominal (rated) displacement 4) s nom mm 0.1 Weight, approx. m kg 3 Degree of protection per DIN EN (IEC 529) oltage supply Operating voltage (DC) Power consumption Start up current Material Housing Diaphragm Bonded seals Base plate U B W A IP66 5) Stainless steel ) Silicone rubber R830 Stainless steel 316L 7) Stainless steel ) 1) As per OIML R60, with P LC = ) As per OIML R76. 3) The values for non linearity (d lin ), relative reversibility error (d hy ) and temperature coefficient of sensitivity (TC S ) are recommended values. The sum of these values is within the cumulated error limits according to OIML R60. 4) Loading with E max and center of gravity in center of platform. 5) When vent hose is properly connected. 6) As per EN ) Gaskets may need protecting against aggressive cleaning agents. HBM 2
3 Specifications (continued) Accuracy class 1) FIT7A Number of load cell verification intervals n LC 4000 Fraction P lc 0.8 Maximum capacity E max kg Minimum load cell verification interval (standard and option 6 = A) Maximum scale interval factor Y (standard and option 6 = A) Temperature coefficient of the zero signal per 10 K (standard and option 6 = A) v min g Y , , TC 0 % of C n Maximum platform size (L x W) mm 400 x x 500 Nominal (rated) sensitivity C n 1,000,000 digit Zero signal 0 100,000 Temperature coefficient of the sensitivity per 10 K 2)3) in the temperature range C TC S C % of Non linearity 3) d lin C n Relative reversibility error 3) d hy Minimum dead load output return MDLOR Off center load error 2) C Nominal (rated) ambient temperature range B T Operating temperature range B tu C Storage temperature range B tl Limit load at 20 mm eccentricity E L 1000 Service load at centric load input % of 150 Relative vibrational stress at max. 50 mm E max F eccentricity srel 70 Nominal (rated) displacement 4) s nom mm 0.1 Weight, approx. m kg 3 Degree of protection per DIN EN (IEC 529) oltage supply Operating voltage (DC) Power consumption Start up current Material Housing Diaphragm Bonded seals Base plate U B W A IP66 5) Stainless steel ) Silicone rubber R830 Stainless steel 316L 7) Stainless steel ) 1) As per OIML R60, with P LC = ) As per OIML R76. 3) The values for non linearity (d lin ), relative reversibility error (d hy ) and temperature coefficient of sensitivity (TC S ) are recommended values. The sum of these values is within the cumulated error limits according to OIML R60. 4) Loading with E max and center of gravity in center of platform. 5) When vent hose is properly connected. 6) As per EN ) Gaskets may need protecting against aggressive cleaning agents. 3 HBM
4 Specifications (continued) Measurement signal resolution bit 24 FIT7A Data rate 1/s Digital filter bandwidth Hz RS-485 interface baud rates baud 1200/2400/4800/9600/19 200/38 400/57 600/ Maximum number of bus nodes 90 CANopen interface (CANopen/DeviceNet) Baud rate Maximum cable length DeviceNet Baud rate Maximum cable length Diagnostics bus RS wire (extended version E) Baud rate Maximum cable length Asynchronous interface RS wire (socket 1) Baud rate Maximum cable length Trigger input (socket 1) Input voltage Low level High level Input resistance Control inputs (extended version E, socket 2) 1) Input voltage Low level High level Input resistance Control outputs (extended version E, socket 2) 1) External supply voltage Max. current per output Max. total current of all outputs 1) The signals apply to GND of socket 1. baud m baud m baud m baud m kω kω A A Standard CiA DS (10 kbaud) 100 (500 kbaud) 25 (1 MBaud) Release 2.0 DA (10 kbaud) 100 (500 kbaud) /2400/4800/9600/19 200/38 400/57 600/ HBM 4
5 Mounting instructions Connection for valve coupling plug (included among the items supplied) Socket 1 Socket 2 *) Mounting plate (not included among the items supplied) Mounting plate flatness <0.02 mm *) ersion E only Electrical connection Device socket 1 Device socket M12 device socket(s), 8 pin FIT7A pin assignment - type S Device socket 1 Pin RS 485 CANopen/DeviceNet Wiring code for 1-KAB165 1) Wiring code for 1-KAB173 1) 1 GND GND White White Brown Brown 3 RA CAN High IN Green Green 4 Trigger input 2) Trigger input 2) Yellow Yellow 5 RB CAN Low IN Gray Gray 6 TB CAN Low OUT Pink Black 7 TA CAN High OUT Blue Blue 8 U B1 U B1 Red Red 1) For digital load cells, HBM recommends two cable types, 1-KAB165 or 1-KAB173, depending on the application. Detailed information about these cables is available in data sheet B3643, which can be found under "Product Data Sheet & Literature" on our website 2) The trigger input is referenced to the GND of pin 1. 5 HBM
6 FIT7A pin assignment - type E Device socket 1 digital communication Pin RS 485 CANopen/DeviceNet Wiring code for 1-KAB165 1) Wiring code for 1-KAB173 1) 1 GND GND White White 2 Diagnosis RbTb Diagnosis RbTb Brown Brown 3 RA CAN High IN Green Green 4 Diagnosis RaTa Diagnosis RaTa Yellow Yellow 5 RB CAN Low IN Gray Gray 6 TB CAN Low OUT Pink Black 7 TA CAN High OUT Blue Blue 8 U B1 U B1 Red Red Device socket 2 inputs and outputs Pin Wiring code for 1-KAB165 1) Wiring code for 1-KAB173 1) 1 - White White 2 IN2 Brown Brown 3 OUT2 Green Green 4 IN1 Yellow Yellow 5 OUT4 Gray Gray 6 OUT3 Pink Black 7 OUT1 Blue Blue 8 U B2 2) Red Red 1) For digital load cells, HBM recommends two cable types, 1-KAB165 or 1-KAB173, depending on the application. Detailed information about these cables is available in data sheet B3643, which can be found under "Product Data Sheet & Literature" on our website 2) For U B2, choose either the same voltage source as for U B1, or a separate voltage source. In both cases, the signals are referenced to the GND with which pin 1 of socket 1 is connected. If a separate voltage source is chosen for the inputs and outputs, this must be connected with the common GND of pin 1. Accessories Suitable connection cables Connection cable with M12 M plug, 8 pin, TPU IP67, PUR cable sheath, 3 m long Connection cable with M12 M plug, 8 pin, TPU IP67, PUR cable sheath, 6 m long Connection cable with M12 M plug, 8 pin, TPU IP67, PUR cable sheath, 12 m long Connection cable with M12 M plug, 8 pin, stainless steel IP68/IP69K, TPE cable sheath, 3 m long Connection cable with M12 M plug, 8 pin, stainless steel IP68/IP69K, TPE cable sheath, 6 m long Ordering number 1-KAB KAB KAB KAB KAB Additional connection cable data can be found in the HBM cables and plugs data sheet (B3643). HBM 6
7 Product numbers (overview) 1-FIT7A Accuracy class C3 (OIML) Maximum capacity Ordering number Remarks 3 kg 1-FIT7ASB3/3KG 1 socket, RS kg 1-FIT7ASC3/3KG 1 socket, CANopen 3 kg 1-FIT7ASD3/3KG 1 socket, DeviceNet 10 kg 1-FIT7AEB3/10KG 2 sockets, RS-485, 2 inputs & 4 outputs, diagnosis channel 10 kg 1-FIT7ASB3/10KG 1 socket, RS kg 1-FIT7ASC3/10KG 1 socket, CANopen 10 kg 1-FIT7ASD3/10KG 1 socket, DeviceNet 20 kg 1-FIT7AEB3/20KG 2 sockets, RS-485, 2 inputs & 4 outputs, diagnosis channel 20 kg 1-FIT7ASB3/20KG 1 socket, RS kg 1-FIT7ASC3/20KG 1 socket, CANopen 20 kg 1-FIT7ASD3/20KG 1 socket, DeviceNet 7 HBM
8 K-FIT7A, optional versions Order no. K-FIT7A N Option 1: Mechanical design Standard C3 C4 Option 2: Accuracy class C3 C4 Option 3: Maximum capacity 3 3 kg 5 5 kg kg kg kg kg kg N Option 4: Explosion protection No ATEX N Option 5: Electrical connection Socket A B Option 6: Miscellaneous 3, 30 kg: Y = 6000; 5, 10, 20, 50 kg: Y = 10,000; 75 kg: Y = , 30, 75 kg: Y = 15,000; 50 kg: Y = 25,000; 10, 20 kg: Y = 20,000 B C D Option 7: Interface Serial interface RS-485 Serial interface CANopen Serial interface DeviceNet S E Option 8: ariant 1 socket, with trigger 2 sockets, with diagnostics bus as well as inputs and outputs K-FIT7A - N - C N - N - A - B - E Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure and predict with confidence HBM 8 Hottinger Baldwin Messtechnik GmbH Im Tiefen See Darmstadt Germany Tel Fax info@hbm.com
WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet
WTX110 Legal-for-trade industrial weighing terminal Special features - Up to 8 SG load cells can be connected (350 ohms) - Stainless steel housing shapes for desktop and wall mounting or control cabinet
More informationWTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet
WTX120 Legal-for-trade industrial weighing terminal Special features - Connection of up to 8 SG load cells (350 ohm) via plug terminals - Display resolution up to 30,000, legal for trade up to 10,000e
More informationU10M. Data Sheet. Force transducers. Special features. Mounting dimensions of the connection variants in mm [inch] B en
U10M Force transducers Data Sheet Special features - Tensile/compressive force transducer - For dynamic and static applications - High endurance at high vibration bandwidths - Electronic bending moment
More informationMX590B-R. Pressure amplifier. Special features. Data sheet. Block diagram
MX590B-R Pressure amplifier Data sheet Special features - Configurable with up to 5 individual pressure transducers - Pressure measurement: absolute, up to 10 ; relative, up to 25 - Sampling rate up to
More informationdigiclip Data sheet DF31CAN Special features B en
digiclip DF31CAN Data sheet Special features Digital amplifier for industrial automation tasks and production process monitoring 600 Hz CF measurement technology with TEDS sensor detection for SG full
More informationdigiclip Data sheet DF31DP Special features B en
digiclip DF31DP Data sheet Special features Digital amplifier for industrial automation tasks and production process monitoring 600 Hz CF measurement technology with TEDS sensor detection for SG full bridges
More informationPrecise weighing fine batching accurate filling
Dynamic weighing with HBM Precise weighing fine batching accurate filling Digital data acquisition in highly dynamic processes using FIT and Dynamic weighing Weighing, batching, filling at high speed Rely
More informationIncremental encoders Solid shaft with clamping or synchro flange pulses per revolution
GI55, GI56 Features Encoder with solid shaft ø mm or ø6 mm Max. 6000 pulses per revolution Optical sensing method Clamping or synchro flange Industrial standard High rotation speed up to 000 rpm Optional
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More informationCX27C. Industrial Ethernet Gateway. Special features. Data sheet. Block diagram
CX27C Industrial Gateway Special features - Gateway between QuantumX measurement modules and -based fieldbuses - Integration with Industrial real-time : PROFINET IRT - Parallel integration with standard
More informationLMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.
LMP 08i Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mh O up to 0... 00 mh O Output signals wire:... 0 ma wire:
More informationMX1609TB. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en
MX1609TB Thermocouple amplifier Type T Data sheet Special features 16 individually configurable inputs (electrically isolated) Thermocouple mini type T Optional measuring point identification (RFID) and
More informationAnalog output linear. Wear free, high resolution High shock resistance Servo flange mounting U8 I1
PTAM2 Robust Inclination Sensor with Analog Output Analog Inclination Sensor for 1 axis or 2 axes in MEMS technology Measurement range ±180 for 1 axis or ±60 for 2 axes class IP67 / IP69K Analog output
More informationInclination sensors 1-dimensional, measuring range
Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R
More informationOperating Manual. Digital Transducer Electronics AED9101D Basic device for AD103C with RS 232, RS 422, RS 485. English. I
Operating Manual English Digital Transducer Electronics Basic device for AD103C with RS 232, RS 422, RS 485 I3563-1.0 en 1 Safety instructions... 3 2 Markings used... 7 2.1 Symbols on the device... 7 2.2
More informationMX809B. Amplifier for thermocouples and voltages (insulated) Data sheet. Special features. Block diagram. Double isolation.
MX809B Amplifier for thermocouples and voltages (insulated) Special features - 8 individually configurable inputs, thermocouples of types K, J, T, B, E, N, R, S, C or electrical voltages up to 5 - Insulation
More informationLMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO
Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signals wire:... 0 ma wire: 0... 0 V others
More informationInclination sensors 2-dimensional, measuring range up to ±90
Features Size 52 mm MEMS capacitive measuring principle EN13849 compliant firmware E1 compliant design Interface CANopen, SAE J1939, Analog Connection M12 and cable Protection up to IP 69K Optional GIM500R
More informationAccessories Fieldbus Box
Power cables, sensor cables, connection cables and further accessories see the EtherCAT Box chapter from page 514 Pre-assembled cables for fieldbus components include a wide range of cable assemblies.
More informationSM9000. Magnetic-inductive flow meter. Made in Germany
Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous
More informationValve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)
Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface
More informationEncoder WDGA 58B CANopen
Encoder WDGA 58B CANopen www.wachendorff-automation.com/wdga58bcan Wachendorff Automation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and
More informationTechnical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means
Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE Switch output and analog output Selectable sound lobe width Synchronization options
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99
More informationM8, M12, 3-, 4-, 5-, 8-, 12-pin, LED, shielded
ACCESSORIES M8, M12, 3-, 4-, 5-, 8-, 12-pin, LED, shielded ipf electronic gmbh Kalver Straße 25-27 58515 Lüdenscheid Germany Tel +49 2351 9365-0 Fax +49 2351 9365-19 111 1000 CABLE SOCKETS NOTES 112 ipf
More informationDigital weighing technology solutions
HBM technology for dynamic weighing processes Digital weighing technology solutions Fast, precise and cost-efficient Overview of measurement applications Clever solutions for dynamic and static applications
More informationFLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet
Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system
More informationThe pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document.
The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document. Rotary Encoder Solutions Limited Dutton Road Redwither Business
More informationDCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor
DCT 5 Industrial Pressure Transmitter with RS85 Modbus RTU Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar output
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationTechnical Data Sheet SONOFLOW CO.55/xxxSD(H) V2.0
Technical Data Sheet SONOFLOW CO.55/xxxSD(H) V2.0 The sensor series SONOFLOW CO.55/xxxSD V2.0 with stainless steel housing and display designed as clamp-on-sensors detect the flow rate of liquids in plastic
More informationAbsolute encoders - bus interfaces Solid shaft with synchro flange Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT
EAM60 - solid shaft CANopen - MAGRES Features Encoder single- or multiturn / CANopen Precise magnetic sensing Angular accuracy up to ±0.1 Additional incremental signals High protection up to IP 67 High
More informationLinear Position Transducer HLT 1000-R2
7 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
sales@jumo.co.uk info.us@jumo.net Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology
More informationAbsolute encoders - bus interfaces Solid shaft with clamping or synchro flange Optical multiturn encoders 13 bit ST / 12 bit MT, RS485
Optical multiturn encoders 1 bit ST / 12 bit MT, RS485 Features Encoder multiturn / RS485 Optical sensing method Resolution: singleturn 1 bit, multiturn 12 bit Clamping or synchro flange Fieldbus protocol
More informationTechnical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 0--9 07:6 Date of issue: 0-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
More informationIB080QM65VA3 Part Number
Inductive Proximity Switch with increased Switching Distance IB080QM65VA3 Part Number Technical Data Inductive Data Switching Distance 8 mm Correction Factors V2A/CuZn/Al 0,93/0,40/0,36 quasi-flush A/B/C/D
More informationAbsolute encoders - bus interfaces Solid shaft with clamping or synchro flange Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT
Features Encoder single- or multiturn / CANopen Precise magnetic sensing Angular accuracy up to ±0.15 Additional incremental signals High protection up to IP 67 High resistance to shock and vibrations
More informationTECHNICAL DATASHEET Absolute Encoder AC 58 - CANlayer2
Diagnostic LED Poll and auto mode Programmable: Direction, limit values Option: Display "tico" Clamping flange TECHNICAL DATA mechanical Housing diameter 58 mm Shaft diameter 6 mm / 10 mm (Solid shaft)
More informationEncoder WDGA 58A CANopen
Encoder WDGA 58A CANopen www.wachendorff-automation.com/wdga58acan Wachendorff Automation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and
More informationInstallation Manual. WKC Weigh Modules
Installation Manual Weigh Modules Table of Contents 1 Installation 3 1.1 Mechanical installation... 3 1.1.1 Support Interface (Support Surface)... 3 1.1.2 Weighing Interface (Weighing Platform)... 3 1.2
More informationPOSIROT. PRAS2EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet
Magnetic Angle Sensors (Dust-Ex-proof) Magnetic Angle Sensor Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part of
More informationEncoder WDGA 36A CANopen
Encoder WDGA 36A CANopen www.wachendorff-automation.com/wdga36acan Wachendorff Automation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
Data Sheet 4000 Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology Brief description
More informationGEN series G070A. Data sheet. Torque/RPM adapter. Special features
GEN series G070A Torque/RPM adapter Data sheet Special features - Connect up to two torque transducers - Connect to T12/T40B using standard cables - RS422 differential input signals for highest immunity
More informationEPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number
Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mh O up to 0... 50 mh O Output signals -wire: 4... 0 ma -wire: 0...
More informationTechnical data. General specifications. Indicators/operating means
Release date: 08-0-08 0:7 Date of issue: 08-0-09 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
More informationOperating instructions Memory plug E /02 11/2011
Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5
More informationCurrent ma Redundant second channel as option
PRAS2 Magnetic Angle Sensor with Analog Output Magnetic angle sensor 0-360 degrees in a flat housing with 36 mm dia. Protection class IP67/IP69K Non-contact with external position magnet Wear free Flat
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationDimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31
OBEM-R00-SEP-IO-V Dimensions. 8.7. 7..9. M (x).. ø... 0 9.9 7. 7. Release date: 08-06-08 :0 Date of issue: 08-06-08 80998_eng.xml Model Number OBEM-R00-SEP-IO-V Thru-beam sensor with -pin, M8 x connector
More informationAMG 11. Features. Optional. Additional incremental output (TTL / HTL) AMG 11. Technical data - mechanical design. Technical data - electrical ratings
Features Multiturn SSI / Profibus / CANopen / DeviceNet / PROFINET Optical sensing method Singleturn 1 bit, multiturn 1 bit / 16 bit EURO-flange B10 / solid shaft ø11 mm Multiturn sensing with microgen
More informationPosition Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX
Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle
More informationLevel sensor Stainless steel version Model RLT-1000, for industrial applications
Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring
More informationDS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.
Pressure Port With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: 0. % FSO Nominal pressure from 0... 60 bar up to 00 bar Contacts, or independent PNP contacts, freely configurable
More informationPosition Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX
Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle
More informationTECHNICAL DATASHEET Absolute Encoder AC 58 - Profibus
Diagnostic LED Cable or M12 connector Output of speed, acceleration Programmable: Resolution, Preset, Direction, Operation time Option: Display "tico" Address via interface parameterizable (optional) hubshaft
More informationstandard, short, preferential, top
ipf electronic gmbh Kalver Straße 27 standard design short design preferential series top series standard, short, preferential, top norm sensing ranges, increased sensing ranges 1100 1 2 1100 norm sensing
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationProximity sensors SME-8, for T-slot Technical data Magnetic reed
Function e.g. N/O contact, with cable, 3-wire Magnetic reed measuring principle Insertable in the slot lengthwise e.g. N/O contact, with plug, 3-pin SME-8-SL Sturdy thanks to long guides Plug directly
More informationSK TU4-CAO-C Part number:
SK TU4-CAO-C Part number: 275 281 151 CANopen External Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their
More informationIncremental encoders Solid shaft with EURO flange B pulses per revolution
Solid shaft with EURO flange B 0 5000 pulses per revolution EIL580 - EURO flange B - OptoPulse Features Size ø58 mm Precise optical sensing Output signal level TTL or HTL EURO flange B Connection axial,
More informationAbsolute encoders - bus interfaces Encoder kit Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT
Magnetic single- or multiturn encoders 1 bit ST / 18 bit MT Features single- or multiturn / CANopen Precise magnetic sensing Angular accuracy up to ±0.1 Additional incremental signals High protection up
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)
More informationModular pressure transmitters for harsh environments DST P500, DST P507 and DST P550
Data sheet Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550 The P500 / P507 / P550 utilizes the thin film strain gauge sensing technology, incorporating an hermetically
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationProduct Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide
Product Information LS 1679 Incremental Linear Encoder with Integrated Roller Guide April 2016 LS 1679 Incremental linear encoder for measuring steps to 5 µm or 1 µm Integrated wear-free roller guide with
More informationAbsolute Encoders Multiturn
The multiturn encoders 5868 and 5888 with interface and optical sensor technology are ideal for use in all applications with a interface. The encoder supports the isochronous (IRT) mode and is therefore
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationMiniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm
Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic
More informationDatasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *
09005318 DB_EN_DE44_LCD Rev. ST4-C 07/17 *09005318* Datasheet DE44 Digital 2-channel differential pressure switch/transmitter with colour-change LCD 1 Product and functional description FISCHER Mess- und
More informationLVX Control Unit. Features:
Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count
More informationAbsolute encoders - SSI
Features Encoder multiturn / SSI Optical sensing Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics Counting direction input Available
More informationInductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationHMG 11. Features. Optional Additional incremental output (TTL / HTL) HMG 11. Technical data - mechanical design. Technical data - electrical ratings
Features Multiturn / SSI / Profibus / CANopen / DeviceNet / PROFINET Optical sensing method Singleturn 1 bit, multiturn 1 bit / 16 bit Blind or through hollow shaft or cone shaft ø16-0 mm Multiturn sensing
More informationP30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application
P30-2 Pressure Transmitter Datasheet At a Glance *High Quality* 3 Years Warranty Premium Pressure Transmitter for gauge and pressure measurement with 3 years warranty High repeatability and long-term stability
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing
More informationMPreC - Pressure Relief Device Order specification sheet
- Pressure Relief Device Order specification sheet -Series LARGE MESSKO PRESSURE RELIEF DEVICE Complete the Order-N o by choosing the specific add-on s: e.g.: LMPRD 685-08-22-N01-00 Order-N o : Parameter
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling
More informationElectrical adapters, Sub-D socket, 9-pin Technical data
Electrical adapters, Sub-D socket, 9-pin Fieldbus adapter FBA Fieldbus adapter Sub-D, 9-pin on M12 or screw terminal, for CANopen and DeviceNet General technical data Electrical connection 1 Straight socket,
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationBL67 electronic module 4 analog inputs for current/voltage BL67-4AI-V/I
Independent of the type of fieldbus and connection technology used Protection class IP67 LEDs indicate status and diagnostic Electronics galvanically separated from the field level via optocouplers 4 analog
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMultiturn absolute encoder
Release date: 207-0-2 :0 Date of issue: 207-0-2 t79_eng.xml Model Number Features Industrial standard housing Ø58 mm PROFINET IRT 0 Bit multiturn Servo or clamping flange Network loop through by means
More informationTechnical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm
Model Number Features 5 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications Switching element function
More informationIncremental Encoder with Hollow Shaft
Incremental Encoder Type RI 36-H n miniature industry encoder for high number of pulses n short mounting length n easy mounting procedure n Application e.g.: - Motors - Machine tools - Packaging Machines
More informationReference Guide METTLER TOLEDO WMH Weighing Platforms
Reference Guide METTLER TOLEDO Weighing Platforms Mettler-Toledo GmbH 2005 Doc.No. KA021, 42908713C Weighing Platforms Reference Guide Contents 1 Initial Setup... 4 1.1 Installation... 4 1.2 Electrical
More informationDigital electropneumatic positioner SideControl
Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Integrated diagnostic functions for valve monitoring (optional) Dynamic positioning
More informationUser Manual AD101B. Digital Transducer Electronics Amplifiers Hardware and Functions. I en
User Manual AD101B Digital Transducer Electronics Amplifiers Hardware and Functions I1690-1.2 en Content 1 Content Typographical conventions... 3 Important information... 3 Safety instructions... 4 1
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:
More informationTechnical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 480 a at 40 C Mission Time (T M ) L 10
Model Number Features Very small housing Up to 31 bit overall resolution CANopen interface Free of wear magnetic sampling High resolution and accuracy Description This absolute rotary encoder provides
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationUser Manual AED9301B. Digital Transducer Electronics Basic Device PROFIBUS. I en
User Manual Digital Transducer Electronics Basic Device PROFIBUS I1694-2.0 en Content 1 Content Typographical conventions... 3 Important information... 4 Safety instructions... 5 1 Introduction and appropriate
More informationInductive displacement measurement system model series IE25P with programmable analogue interface
Inductive displacement measurement system Document No.: IE 12781 BE Date: 05.01.16 Contactless, wear-free sensor system Analogue interface Measuring range programmable Measuring range up to 0 mm Stainless
More informationRK-4 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH THREADED HEAD
RK-4 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH THREADED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-4- -N/E/S) Digital output
More informationATM 60/ATM 90: Multiturn Absolute Encoders extremely robust and exceptionally reliable.
ATM 60/ATM 90: Multiturn Absolute Encoders extremely robust and exceptionally reliable. With SSI- or RS 422 configuration interface, Profibus, CANopen or DeviceNet field bus technology, all current interfaces
More informationTechnical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B
Model Number Cable pull rotary encoder with PROFI- NET interface Features Robust aluminum drum housing Drum travel when cable retracted using threaded spindle Bellows with steel tip Comprehensive accessories
More information