PERMANENT DOCUMENT. Annex AU to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

Similar documents
CONTENTS 3 EN :2006

UL TEST REPORT AND PROCEDURE

Please use the Q & A utility to ask us any questions concerning the material being presented.

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

Protection against electric shock

LED Driver Compact fixed output

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

PAT-Cal 2 TECHNICAL MANUAL

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

F550e E-learning course Residual current devices basics RCDs Standards. ABB Group April 2, 2009 Slide 1

File E Project 91SC COMPONENT POWER SUPPLIES INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

LED Driver Linear / area dimming

LOW WEIGHT, SMALL SIZE,

LED Driver Compact fixed output

LED Driver Compact fixed output

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

UL TEST REPORT AND PROCEDURE

Operating Instructions

LED Driver Linear / area fixed output

LED Driver Compact fixed output

UL TEST REPORT AND PROCEDURE

LED Driver Compact fixed output

Standards Update Notice (SUN) Issued: April 25, 2017

LED Driver Linear / area fixed output

UL TEST REPORT AND PROCEDURE

Great Western Painting Assured Equipment Grounding Conductor Program OR Ground Fault Circuit Interrupter (GFCI)

C E R T I F I C A T E O F C O M P L I A N C E

AC/DC TRUE RMS CLAMP METER ACM-2036

Operating Instructions

LED Driver DC-String

LED Driver Compact fixed output

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 3

LED Driver Linear / area fixed output

LED Driver Compact fixed output

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

110.4 Use of Equipment.

UL TEST REPORT AND PROCEDURE

M E M O R A N D U M I.S.

ETSI EN V1.2.1 ( )

LED power supplies Constant voltage. Uconverter LCU 180W 12/24V IP67 TOP Outdoor IP67 series

Application Note. CPE Industry Specifications: UL60950 and TIA-968-A

LED Driver Compact fixed output

S82S (3/7.5-W Models)

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

LED Driver Compact fixed output

Test Report S

Line Impedance Stabilization Network (LISN)

Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

LED Driver DC-String

LED Driver Constant voltage. Udriver LCU 100/96W 12/24V IP67 EXC EXCITE outdoor IP67 series

OPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT MODEL

LED Driver Constant voltage. Udriver LCU 180W 12/24V IP67 EXC EXCITE outdoor IP67 series

LED Driver Compact fixed output

ClareHAL 104 Electrical Safety Tester

Specification Voltage Limiting Device

UL TEST REPORT AND PROCEDURE

REYROLLE 2RMLG. Operating Recommendations

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

GROUND FAULT CIRCUIT INTERUPTERS

CENTRAL MARKS DEPARTMENT-III

Miniature Circuit Breakers for Railway Applications

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

UL TEST REPORT AND PROCEDURE

Portable Appliance Tester KT75 OPERATORS MANUAL

Application Note. Table 1. Test requirements by equipment type

Safety and Radio-Frequency Interference

C E R T I F I C A T E O F C O M P L I A N C E

PAT300 Series Portable Appliance Testers User Manual

UL TEST REPORT AND PROCEDURE

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

SRI LANKA STANDARD CODE OF PRACTICE FOR GRID CONNECTED PHOTOVOLTAIC POWER SYSTEMS SLS 1522:2016

LED Driver Compact dimming

OPERATOR S MANUAL BOP (M) (D) 100W, 200W, 400W BIPOLAR POWER SUPPLY

Certification Process Household and Similar Equipment

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

LED Driver Compact fixed output

LED Driver Linear / area dimming

Zener Barriers Bulletin 937Z

E A54-UL 2012-AUGUST-29 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

High Performance Network Isolator

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

UL TEST REPORT AND PROCEDURE

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

LED Driver Constant voltage. Driver LC 200W 24V SC SNC essence series

Applying branch circuit breakers and supplementary protectors in North America

LED Driver Compact dimming

Bulletin Installation of Solar Photovoltaic Systems Section 50; Rules: , , ; Tables 11 and 19 Issued July 2010

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

Transcription:

PERMANENT DOCUMENT ENEC 303 Annex AU Annex AU to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement) Safety requirements of Audio/video, information and communication technology equipment covered by EN 62368-1 Approved by: Secretary General No. of pages: 6 Date of issue: September 2015 Supersedes: New document page 1 of 6 EEPCA, the European Electrical Products Certification Association 17 rue de l Amiral Hamelin F-75783 Paris Cedex 16 Tel.: +33 (0)140373563 Email: secretariat@eepca.eu Document issued and distributed by EEPCA EEPCA 2015 all rights reserved

Annex AU to PD ENEC 303 Safety requirements of Audio/video, information and communication technology equipment covered by EN 62368-1 1 ROUTINE TESTS (100%) 1.1 Visual check of marking and workmanship. 1.2 Resistance of protective bonding system. For class I equipment, the continuity of the protective bonding system shall be checked between the protective earth contact of the mains plug or appliance inlet, or the protective earthing terminal in case of a permanently connected equipment, and the accessible conductive parts that need to be connected to the protective earthing terminal for compliance with the requirements of the standard, and the protective earth contact of the socket-outlets respectively, if provided to deliver mains power to other equipment. NOTE 1 Functional earth is not considered a part of the protective bonding system and as a consequence, it does not need to be tested. The minimum test current is 150 % of the rating of the overcurrent device protecting the protective bonding conductor (the protective current rating), but not less than 10 A and not more than 25 A (a.c. or d.c.), applied for any duration between 1 s and 4 s. The source shall have a no-load voltage not exceeding 12 V. The resistance, calculated from the voltage drop, shall not exceed 0,1 Ω. It is permitted to include the power cord (if any) in the resistance measurement and, if the result exceeds 0,1 Ω, to subtract the resistance of the protective earthing conductor of the power cord. NOTE 2 Care should be taken that the contact resistance between the tip of the measuring probe and the conductive part under test does not influence the test result. 1.3 Electric strength test Routine tests for electric strength shall be carried out between circuits connected to the mains (primary circuits) and accessible conductive parts. For accessible circuits not connected to the mains (secondary circuits), it is permitted to test separately, before final assembly, subassemblies and components, such as transformers, if the PD ENEC 303 Annex AU - September 2015 page 2 of 6

relevant insulation cannot be tested in the complete equipment, provided that the complete equipment complies with EN 62368-1 as appropriate. The insulation of the equipment shall be checked by the following test. For an equipment supplied by an a.c. mains, an a.c. test voltage of substantially sinewave form, having mains frequency, or a d.c. test voltage or a combination of both with a peak value as specified in Table 1 is applied. For equipment supplied by a d.c. mains, a d.c. voltage according to Table 2 is applied. The test voltages given are the minimum test voltages to be applied. Higher voltages are allowed at the discretion of the manufacturer provided the insulation is not damaged due to overstress by the voltage applied. NOTE 1 Applying an electrical strength test voltage that is too high may result in deterioration or partial damage of the insulation. The test voltage is applied between the supply terminals connected in parallel and terminals regarded as accessible, and accessible conductive parts respectively, that may become hazardous live (ES3) in the event of an insulation fault as a result of incorrect assembly. NOTE 2 Terminals regarded as accessible and accessible conductive parts may be connected together during the electric strength test. Table 1 Test voltage for equipment with a.c. mains Test voltage V (peak) a.c or d.c. Application of test voltage Accessible parts connected to protective earth Accessible parts not connected to protective earth Rated mains voltage 150 1 130 (800 r.m.s.) 2 120 (1 500 r.m.s.) Rated mains voltage > 150 2 120 (1 500 r.m.s.) 3 540 (2 500 r.m.s.) Functional earth is not considered to be protective earth. Accessible parts connected to functional earth have to be tested as not being connected to protective earth. Table 2 Test voltage for equipment with d.c. mains Application of test voltage Up to and including 60 V Test voltage V d.c. Over 60 V up to and including 10 kv Accessible parts connected to protective earth No test see Va in Table 3 Accessible parts not connected to protective earth No test see Vb in Table 3 Functional earth is not considered to be protective earth. Accessible parts connected to functional earth have to be tested as not being connected to protective earth. PD ENEC 303 Annex AU - September 2015 page 3 of 6

Table 3 d.c. test voltages U d.c. V a d.c. V b d.c. > 60 62 64 66 68 70 72 74 76 78 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 152 a 155 a 160 a 165 a 170 a 175 a 180 a 184 185 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 380 400 420 440 460 480 500 520 540 560 580 588 600 921 935 947 962 976 988 1001 1014 1027 1039 1052 1082 1110 1138 1167 1193 1219 1244 1268 1294 1316 1340 1363 1386 1407 1551 1571 1608 1644 1681 1717 1751 1783 1817 1848 1881 1910 1941 1971 1999 2029 2057 2084 2113 2166 2219 2269 2319 2367 2414 2460 2506 2549 2593 2636 2651 2677 1472 1495 1517 1538 1560 1581 1602 1622 1643 1663 1683 1731 1777 1821 1865 1909 1950 1991 2031 2069 2107 2145 2180 2217 2253 2262 2286 2320 2353 2387 2419 2450 2476 2482 2513 2573 2631 2689 2746 2800 2853 2906 2958 3008 3057 3105 3153 3200 3247 3292 3336 3379 3466 3549 3630 3709 3787 3862 3937 4009 4079 4149 4217 4242 4242 NOTE Linear interpolation is permitted between the nearest two points. a At these voltages, the values of V b are determined by the general curve V b = 155,86 U 0,4638 and are not 1,6 V a. Before the test voltage is applied, intimate contact shall be made between the equipment and the connection devices. The voltage applied to the insulation under test may be gradually raised from zero to the prescribed voltage and maintained at that value for 1 s to 4 s. PD ENEC 303 Annex AU - September 2015 page 4 of 6

During the test, mains switches and functional switches conductively connected to the mains, if any, shall be in the on-position and it shall be ensured by suitable means that the test voltage is effectively connected to the equipment. No flash-over or breakdown shall occur during the test. The test voltage source shall be provided with a current sensing (over-current) device which, when activated, gives an indication "unacceptable". When loaded up to and including the overcurrent activation point, the voltage source shall still deliver the prescribed voltage. NOTE The manufacturer may define what the minimum tripping current must be, making sure it is high enough to detect breakdown but at the same time taking into account possible operator safety issues. Activation of the current sensing device is regarded as a flash-over or breakdown. 1.4 Components It is assumed that components comply if they bear a certification mark of an ECS certification body. If components are manufactured by the supplier and do not bear a certification mark, he has to add to each delivery a confirmation that the relevant tests on the components are performed. The manufacturer of information technology equipment is responsible for the proper performance of the tests. In any doubt, the certification body is allowed to inspect the component manufacturer. 2 PERIODIC TESTS A sample of each series/family (same basic construction) shall be subject to complete tests or the main critical tests depending on the results of the pre-license according to the standard at least once a year. The above mentioned tests have to be specified by the manufacturer in a testing or working instruction. 3 RECORDS All test results shall be kept available. The choice of support and format for reports is left to the manufacturers; separate forms (one for each equipment), or grouped according to the most suitable parameters (periods of time, model, etc.) are equally acceptable. The only obligation is the availability of data and their immediate interpretability for all equipment leaving the production line. For every device tested, the following data shall be filled: date of test PD ENEC 303 Annex AU - September 2015 page 5 of 6

model or type designation of the device serial number of the device or another identifier permitting the identification without ambiguity value of earthing circuit resistance with the corresponding current value (*) value of voltage applied during the electric strength test (*) quick-reference information that the whole set of tests has/has not been successful reference to test equipment used for the tests. As an alternative to the values referred with an (*) above, the information of the accomplishment of each test (e.g. pass or fail) is permitted, if the pass/fail criteria are described elsewhere on the test report. PD ENEC 303 Annex AU - September 2015 page 6 of 6