Ink-Dot Series II Driver

Similar documents
Standard icontrol Power Supply Kit

Series 3000V Input/Output Board

AutoScan to MultiScan Replacement Kit

Coolwave 2 Control Board Upgrade Kit

Pro-Flo System Digital Controller EPROM Upgrade

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Sure Coat Modular Gun Control System Part C: UCS ProfiBus Interface Card. Customer Product Manual Part B

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

o-o Nordson Manual (S)46.10 Series 2000 Hose/Gun Temperature Controller (S)46.10=Issued Corporation 1987 Publication No.

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

AFC Control Kit Installation Kit P/N

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PLC Racks IC697CHS782/783

Replacing a Precision Controller Circuit Board

BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE

Instruction Sheet WPC 2000 Option 1

OBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

P1 PowerStation Backlight Bulb

WARNING ELECTRICAL SHOCK HAZARD

KEYSTONE OM13 - EPI-2 3-WIRES MODULE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Sure Coat Modular Gun Control System Part C: Discrete I/O Interface Card. Customer Product Manual Part B

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

User's Guide. Model W 3-in-1 Switching DC Power Supply

This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

ILC LightLEEDer MicroLite 1000P Retrofit Installation

INSTALLATION INSTRUCTIONS

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G)

Prodigy Color-on-Demand System Generation III

13 MMC for PC Option Modules

Sure Coat Modular Gun Control System Part C: Purge Timer Interface Card. Customer Product Manual Part B

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Installation & Operation Guide

icontrol 2 Opto Input Interface Card Replacement

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

PACSystems RX7i IC698CHS009/119

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

INSTALLATION INSTRUCTIONS

Encore XT Manual Gun Upgrade Kit

PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

PowerLogic ION7550 / ION7650 Hardware Lockable Meter

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Superfeed SVF 888 Variable Frequency Controller

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Pegasus HC Lighting Control Panel

Model HM-535 Power Supply Installation and Service Instructions

THE CTB08D LIGHT CONTOLLER

SmartVFD Disconnect Panel Assemblies

INSTALLATION INSTRUCTIONS

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Connecting a Cisco Output Module

TDM To MiniMech conversion ProceDure

Fredenstein Bento 10 Module Carrier

Troubleshooting Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions

EPROM Replacement for Contrbl Systems

Basketball Shot Clock Set LX2180 Manual

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Document Accelerometer Kit KBTXACTEXT

SM Sygnus Hybrid Quick Installation Guide Version

EcoBead Programmer. Safety. Description. Instruction Sheet P/N _01. Qualified Personnel

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

PS/IO Circuit Board Retrofit

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

InView Firmware Update

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Dell Edge Gateway. Service Manual Series

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

VS510SZ Tech Sheet. Balboa Instruments. System PN System Model # VSP-VS510SZ-DCAH Software Version # 43 EPN # 2765

Trigger I/O Board for the LogiComm Gun Driver

Instructions to Install Retrofit Kit 6/7000 Machine

VM 6.1. Capacitive Air Gap Measuring Chains User s Manual P/N: M7A-110

CS5100DV Tech Sheet. Cal Spas. System PN System Model # VSP-CS5100DV-BCAH Software Version # 46 EPN # 3288

Installation & Operation Guide

Installing and Configuring Rialto Analytic Appliances

PACSystems* RX3i IC695PSA140

Model 2380 Rack-Mount Kit

E1135C PDU and Pod Upgrade Procedure

5401 and 5402 Digital I/O Modules

InView Marquee Message Display

FOR SERVICE TECHNICIAN S USE ONLY

Robocolor II System. users guide

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Series 3700 Screw Terminal Assemblies Installation Instructions

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Transcription:

Instruction Sheet P/N 766B Ink-Dot Series II Driver Introduction See Figure. Ink-Dot Series II controllers can have from one to three driver modules. Any existing controller can easily be retrofit with the Series II driver. The Ink-Dot Series II Driver provides the following features: NOTE: Any combination of delay, duration, and double-dotting can be selected by the customer. To make adjustments, refer to Dot Adjustment on page 5. Adjustable dot duration Adjustable delay Double-dot option Extended masking time (to assist in the reduction of unwanted double dots) Figure Ink-Dot Series II Controllers/. One or two applicator controller (one driver module). Three or four applicator controller (two driver modules). Five or six applicator controller (three driver modules) 005A 00 Nordson Corporation Part 766B

Ink-Dot Series II Driver Installation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. WARNING: Disconnect equipment from line voltage. Failure to observe this warning could result in personal injury, equipment damage, or death. Reusing the Series I Input and Output Connectors. Pull the connectors off of the Series I driver, leaving the wires intact.. Pull the input and output connectors from the Series II driver and save them as replacements.. Disconnect the wires from the Series I driver module s power connector.. Disconnect the Series I driver s ground wire from the enclosure. Removing the Existing Driver. Shut off all power to the controller. Allow two minutes for the driver to dissipate any residual electrical charge.. See Figure. Remove the screws () and washers () to remove the existing driver module () from the enclosure ().. Carefully pull the driver module out of the enclosure. Input and Output Wiring See Figure. There are two input (, ) and two output connectors (6, 8) on each driver module (). The input connectors receive the sensor signal. The output connectors relay the sensor signal to the applicator so the proper delay and duration of the dot is achieved. The four input and output connectors are orange. The Series I driver s input and output connectors may be reused if they are in good condition when you replace the Series I driver module with the Series II driver module. Replacing the Input and Output Connectors. If the input connectors (, ) and output connectors (6, 8) on the driver module () need to be replaced, remove the wiring from the connectors.. Match up the numbers on the wires with the numbers on the Series II orange input and output connectors and attach the wires. Table Gun Driver Wire Designations Code on Wire Code Description First Position Second and Third Position through 9 Applicator 0 through 09 Connection. Disconnect the wires from the Series I driver module s power connector.. Disconnect the Series I driver s ground wire from the enclosure. Part 766B 00 Nordson Corporation

Ink-Dot Series II Driver 8 7 0 9 6 Figure Ink-Dot Series II Driver (One or Two Applicator Driver Shown). Enclosure 6. Applicator output connector. Applicator input connector (orange) (orange). Applicator input connector (orange) 7. Applicator head dip switches. Power connector (gray) 8. Applicator output connector (orange) 5. Fuses 9. RUN/OFF/TEST switch 5 005A 0. Front panel dip switches. Screws (). Washers (). Driver module 00 Nordson Corporation Part 766B

Ink-Dot Series II Driver Power Wiring WARNING: Ground each driver module to the controller cabinet. Connect each driver module s ground wire to the controller cabinet ground stud. Failure to observe this warning may result in personal injury, equipment damage, or death. See Figure. Power and neutral wires are connected and daisy-chained to each module s gray power connector (). Use Table to connect the input power wires to the driver modules and daisy-chain power to other modules. Installing the Driver. See Figure. Snap the gray power connector () into the Series II driver module. NOTE: The gray power connector is keyed to fit only into the power socket.. Snap the input connectors (, ) and output connectors (6, 8) into the Series II driver module. NOTE: Be careful to properly position the input and output connectors on the Series II driver.. After all connections are complete, place the Series II driver module () into the enclosure () and secure it with the screws () and washers (). Table Input Power Wiring/Daisy-Chaining the Quantity of Terminal Function L: Input Power L: Single Driver Output Power Module L: L: Quantity of Terminal Function L: Input Power L: Two Driver Output Power Modules L: L: Quantity of Terminal Function L: Input Power Three Driver Not Used Modules L: Not Used Part 766B 00 Nordson Corporation

Ink-Dot Series II Driver 5 Dot Adjustment NOTE: When you first start up the driver, make sure that the front panel dip switches are in the factory-set positions illustrated in Figure.. See Figure. Put the RUN/OFF/TEST switch (9) in the TEST position.. Observe the dots being produced.. See Figure. Use the following guidelines to adjust the front panel dip switches to achieve the desired results. NOTE: Each set of dip switches controls one channel (applicator) of the driver. The dip switches allow individual adjustment for each applicator. Switches Function Double Dot Factory Default Setting Off Adjustment Range On/Off,, Delay 0 MS 0-8 MS ( MS increments) 5, 6, 7, 8 Duration.0 MS 0.-.9 MS (0. MS increments). When all necessary adjustments have been made, put the RUN/OFF/TEST switch in the RUN position. Figure Front Panel Dip Switches. Double dot switch. Duration switches. Delay switches Note: The shaded areas in Figure represent the actual dip switch. 005A 00 Nordson Corporation Part 766B

6 Ink-Dot Series II Driver Parts See Figure. Item Part Description Quantity Note,, 6, 8 6875 INPUT/OUTPUT CONNECTOR, plug, orange, pin, with label 9755 POWER CONNECTOR, plug, gray, pin, with label 5 99967 FUSE,.5 amp, fast acting, 50 V, 5 x 0 mm 0 7686 SWITCH, dip, 8 position 5 DRIVER MODULE, series II, Ink-Dot AR Issued 9/0 Original copyright date 997. Nordson and the Nordson logo are registered trademarks of Nordson Corporation. Ink-Dot is a trademark of Nordson Corporation. Part 766B 00 Nordson Corporation