1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

American Weigh Scales, Inc. AMW-BENCH. D i g i t a l T a b l e t o p S c a l e. User Manual

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

9. FUNCTION MENU SETTINGS -TION FUNCTION DESCRIPTION DEFAULT. VALUE F0 H-L SEt Lo Set a value for the Low

Trade Approved Version NMI: S520

Oxford E Series. Instruction Manual

TWP series. Weighing Indicator Service Manual

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

TWP-W. Weighing Indicator Service Manual

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

User Manual MODEL DIGI SERI DS

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

AELP PALLET BEAMS SCALES

NB/NHB Precision Balance

MC Piece Counting Scale

SAC / SHC / SHC-CH SERIES

Totalcomp TLI Indicator. Operation and Maintenance Manual Manual

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

TRWS series. Waterproof indicator User s guide UGTRWS-E1.1

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

Integrator C15/C30 Manual

! User Manual Rev. 1

Weighing Indicator M701. Handrail scales. REV: M1, April,05,2014 (v )

DL Series NEWDOLBO OWNER S MANUAL. Simple Weighing Scale 9002-DL

BBA-Series Precision Balances

EDGE. Digital Kitchen Scale. 11lb x 0.1oz 5000g x 1g

1.0 Description. 2.0 Unpacking. 3.0 Installation

Weighing Indicator Service Manual V1.24X

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL

PS-C60K-D. Counting Scale Service Manual

BW/BWS Weighing Indicator

EC100. Counting Scale. Operations Manual (V1611)

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

YJ Carat and Gold Scales

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

PS-IN202 Weighing Indicator User Manual

OHAUS Asia-Pacific Dealer Meeting March 23-25, 2010 Hua Hin, Thailand Compact & Counting Scales

Visit for discount prices on Acculab Scales SVI SERIES PROFESSIONAL PRECISION INDUSTRIAL SCALE SVI-10A SVI-20B SVI-50C SVI-100E SVI-200F

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED


AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

Simple Weighing Scale. SW-1S / 1C Series OWNER S MANUAL 9002-SW

STANDARD OPERATING PROCEDURE AA SERIES AA-160 PRECISION BALANCE

What s In The Box. Key Descriptions. - ON/OFF - Turns the scale MOXIE ON or OFF. PCS - Enter counting mode. Hold to set sample quantity for average

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY

Adam Equipment LBK SERIES. (P.N. 9596, Revision D, July 2014)

1. Introduction Specifications Operation Guide Trouble-shooting Note... 13

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050

Multi-Function Smart Indicator User Manual

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

PLATINUM PRO6000 PROFESSIONAL SERIES DIGITAL COUNTERTOP / PORTABLE BALANCE

PLATINUM PRO1001DXP DIGITAL COUNTERTOP / PORTABLE BALANCE

MI101 / MI102 / MI102S INDICATOR

This document hosted by: Ranger 7000 Scales Instruction Manual

OMEGA SERIES COUNTING SCALE

BW/BWS/VW/CW/NTW/NSW. Weighing Indicator

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale

uline.com OVERVIEW OF CONTROLS. k g. Tare Menu. Exit. Print. Units PRINT

OHAUS SCOUT BALANCE SCALE

Compact Balances. EK-610j EK-6100j. in an Authorized A&D Dealer

Instruction Manual for. Torbal AGZN Series Balances

INTRODUCTION INSTALLATION

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

OP-W Series User Manual

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

Precision Balance W3200 Series Operating Manual

Price Computing Scale ER Series

ES210. Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd

Instruction Manual for. Torbal AGCN Series Balances

PX Series Balances. Quick Start Guide. Please download the user manual from

PLATINUM PRO1001V DIGITAL COUNTERTOP / PORTABLE BALANCE

Counting Scales. HC-i Series

Model Bulk Sampling Scale. User s Manual

Division Services. Model: DPAS-300. Division Portable Bulk Load Accumulator Scale INDUSTRIAL PH (901) FAX (901)

Operating instruction Platform scale

Operating instructions METTLER TOLEDO BD balances

QB Series. Operation Manual. Precision Balance. To be the best by every measure

AJ Series. Intelligent-Lab NTEP Centigram Balance. Made in Japan

Acaia Pearl Operation Manual

SELECTING THE LOCATION PREPARATION FOR USE. Pan Calibration Mass (only for SJX/E models with 64g capacity) Scoop (only for models with 64g capacity)

Sartorius Research. R 160 P Electronic Semi-Microbalance

CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...

TL-Series. User Manual. American Weigh Scales. TL-330 (330lb x 0.2lb) TL-440 (440lb x 0.5lb)

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

Cautions for Your Safety

WUNDER SA.BI.SRL EN USER MANUAL. MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual

Transcription:

EHC-WF User/Technical Manual Contents subject to change without notice Version 1.0 7/2017

TABLE OF CONTENTS 1. INTRODUCTION... 1 General and Safety Information... 1 Specifications... 1 2. Unpacking and Setup... 2 Contents... 2 3. OVERVIEW OF CONTROLS AND FUNCTIONS... 2 3.1 Front Display... 2 3.2 Indicator Display Character Definitions... 3 3.3 Key Functions... 4 4. OPERATIONS... 5 4.1 Power on / Power off scale... 5 4.2 Zeroing the display... 5 4.3 Taring... 6 4.4 Switching measuring unit... 6 4.5 Normal Weighing Mode... 6 4.6 Gross and Net weight... 6 4.7 Checking Weighing Mode... 6 4.8 Counting Mode... 7 4.9 Percent Weighing Mode... 7 5.10 Mannual Accumulation... 8 5.11 Automatic Accumulation... 8 4.12 Print (output) data via RS232 interface... 9 5. Calibration... 9 6. Parameter Setup Mode... 10 7. Display and Key test... 11 8. Display A/D code and working voltage... 11 9. Display symbol meaning... 12 10. Troubleshooting... 13 10.1 Troubleshooting... 13 10.2 Battery and Charging... 13

1. INTRODUCTION General and Safety Information For use in dry environments only. This product uses a Lead-acid rechargeable battery. Dispose of according to local laws and regulations. Read and understand all operating instructions before using this product. Keep this manual for future reference. Allow sufficient warm up time. Turn the scale on and allow up to 10 minutes for internal components to stabilize before weighing. Record the weight shortly after placing a load on the platter. Leaving loads in place for extended periods may vary the load cell s output signature and may result in a less accurate reading. Avoid extended exposure to extreme heat or cold. Optimum operation is at normal room temperature. See operating temperature range in the specifications table. Allow the scale to acclimate to room temperature before using. When storing the scale for extended periods, the battery must be charged every 90 days to avoid premature performance degradation. Over time, the operating time per charge will degrade. If the operating time is no longer acceptable even after recharging, the battery must be replaced. Electronic scales are precision instruments. Do not operate near cell phones, radios, computers or other electronic devices that emit radio frequencies that may cause unstable readings. Specifications Model EHC-WF-0612 EHC-WF-1530 EHC-WF-3060 EHC-WF-60120 Max. Capacity 6 kg (12 lb) 15 kg (30 lb) 30 kg (60 lb) 60 kg (120 lb) Readability 0.2 g (0.0005 lb) 0.5 g (0.001 lb) 1 g (0.002 lb) 2 g (0.005 lb) Display Resolution 1:30000 Min. Recommended Weight 4 g (0.01 lb) 10 g (0.02 lb) 20 g (0.04lb) 40 g (0.1 lb) Min. Recommended Sample Weight (1%FS) 60 g 150 g 300 g 600 g Construction Stainless steel pan, plastic housing Weighing Units kg /g/lb/oz Calibration unit kg / lb Modes Weighing, Counting, Check Weighing, % weighing, Accumulation, G/N weight Weight Display 1-Window backlit LCD display, 50mm (2 ) high, 6 1/2 digits, 7-segment Zero Range Power-on zero range: calibration zero point±10%fs; ZERO key range: power-on zero±5%fs Tare Range Full capacity Stabilization Time <5 seconds Operating Temperature 14 to 105 F (-10 to 40 C) Humidity Range <90% relative humidity, non-condensing Power Supply 6V 4Ah lead-acid battery or AC power adapter (12Vdc/500mA with central positive) Battery Performance 80 hours continuous use with 12 hour recharge time (with backlit OFF) External Interface RS232 and USB Safe Overload Capacity 150% of capacity Platter Dimensions (L x W) 335 x 225 mm; 13.2" x 8.9" Scale Dimensions(L x W x H) 355 x 370 x 133 mm; 14" x 14.6" x 5.24" EHC WF. 1.

2. Unpacking and Setup Remove the scale from the box and place it on a firm, level surface. Avoid locations with rapid temperature changes, excessive dust, moisture, air currents, vibrations, electromagnetic fields, heat or direct sunlight. Adjust the leveling feet until the bubble is centered in the circle of the level indicator (located on the front panel). NOTE: Ensure that the scale is level each time its location is changed. The internal rechargeable battery should be fully charged for up to 12 hours before using the scale for the first time. Connect the supplied AC adapter to the power input receptacle underneath the scale. Plug the AC adapter into a properly grounded power outlet. The battery will begin charging. If the scale will be stored or transported in the future, save the packaging material to ensure the best possible protection for the scale. Contents Scale 12Vdc/500mA adapter Manual 3. OVERVIEW OF CONTROLS AND FUNCTIONS 3.1 Front Display - Scale is zeroed, gross weight is 0, tare is 0. - Scale is stable. NET - Display reading is net weight; tare is not 0. GROSS - Display reading is gross weight; - Display data is accumulated total times, weight, pieces. TARE - Display reading is net weight; tare is not 0. lb - Measure unit is lb. oz - Measure unit is oz. kg - Measure unit is kg or g. % - Measure unit is % (in percentage weighing mode). Pcs - Measure unit is pieces (in counting mode). HI - Check-weighing is enabled. Current data is above the specified upper limit. OK - Check-weighing is enabled. Current data is between the specified upper and lower limits. LO - Check-weighing is enabled. Current data is below the specified lower limits. - Battery level. EHC WF. 2.

3.2 Indicator Display Character Definitions EHC WF. 3.

3.3 Key Functions ~ Press to enter number in counting and checking weighing modes and calibration Press to clear the input number or accumulated value Press to tare the weight when reading is stable, tare range: 100%FS Press to confirm the operation or entered data Press to set the zero point after the scale is stable, zero range:power-on zero point±5%fs Press to add the value to the accumulation memory Press and hold to display the accumulated total value Press to switch the measuring unit between kg, g, lb and oz Press to confirms the operation or saves the data Press to output data via RS232 port Press to enter checking weighing mode, set Hi and Lo value EHC WF. 4.

Press to enter % weighing mode In counting mode, press to display unit weight(g/pcs), total weight(kg) or count(pcs) Press to enter into counting mode Press to exit the current working mode and return to normal weighing mode In weighing mode, obtain piece weight and enter into counting mode; In counting mode, obtain piece weight by weighing a known quantity In weighing mode, input piece weight and enter into counting mode; In counting mode, input piece weight In weighing mode, switch between gross weight and net weight + + + Press to power on the scale when the scale is off Press and hold to power off the scale when the scale is on Press to return normal weighing mode when scale is in parameter setting mode Press to enter calibration mode Press to enter parameter setting mode Press to check inner code and voltage 4. OPERATIONS 4.1 Power on / Power off scale Place the scale on a flat, stable surface. Level the scale using the leveling bubble at the lower left side of the display. With the weighing platter empty, turn on power switch (located underneath on the left-hand side of the scale). Press and hold the ON/OFF key to power on the scale. The self-check will run and the scale will display a zero reading. When the scale is beyond the power-on zero point range (calibration zero point +/- 10%FS), after powering on, the scale displays Err04 or Err05. To power off the scale, press and hold ON/OFF key again. 4.2 Zeroing the display You can press the ZERO key at any time to set the zero point from which all other weighing and counting is measured, within + 5% of power up zero. This will usually only be necessary when the platform is empty. When the zero point is obtained the display will show the indicator for zero. When the scale is beyond the zero key range (Power-on zero point +/- 5%FS), after powering on, the scale displays Err04 or Err05. EHC WF. 5.

4.3 Taring Zero the scale by pressing the ZERO key if necessary when reading is stable. The zero indicator will be on. Place a container on the platform, a value for its weight will be displayed. Press the TARE key to tare the scale. The weight that was displayed is stored as the tare value and that value is subtracted from the display, leaving zero on the display. The "NET" and "Tare" indicator will be on. As product is added, only the weight of the product will be shown. The scale could be tared a second time if another type of product was to be added to the first one. Again only the weight that is added after taring will be displayed. When the container is removed a negative value will be shown. If the scale was tared just before removing the container this value is the gross weight of the container plus all product that was removed. The zero indicator will also be on because the platform is back to the same condition it was when the ZERO key was last pressed. 4.4 Switching measuring unit In normal weighing mode, press Unit key to switching the measuring units between kg, g, lb and oz. 4.5 Normal Weighing Mode When scale is powered on and back to 0, first tare the empty container then place the sample in the container. The display will show the weight and the units of weight currently in use. 4.6 Gross and Net weight In tare mode, press G/N key to switch between gross weight and net weight. When gross weight is displayed, GROSS light will be lit; when net weight is displayed, NET light will be lit. 4.7 Checking Weighing Mode Check-weighing is a procedure to cause an alarm to sound when the weight, quantity or % weight on the scale meets or exceeds values stored in memory. The memory holds values for a high limit and a low limit. Either limit can be used or both can be used. Press the Hi/Lo key. The display will show COMP, then show HIGH, then display 0, user 0-9 keys to input the value, press the Enter key to confirm. If you want to reset the value to zero press the Clear key to clear the value. After pressing the Enter key the display will then show Low. Enter the low limit in the same way the high limit was entered. After pressing the Enter key the scale will return to weighing with the Check weighing function enabled. When a weight is placed on the scale the HI/OK/LO symbol will be shown if the weight is above or below the limits and the beeper will sound as described below. BOTH LIMITS SET The display will show OK and the beeper will sound when the weight is between the limits. LOW LIMIT SET, HIGH LIMIT is set to zero The display will show OK and the beeper will sound when the weight is less than the Low Limit. Above the Low Limit the display will show HI and the beeper will be off. HIGH LIMIT SET, LOW LIMIT is set to zero The display will show LO and the beeper will be off when the weight is less than the High Limit. Above the High Limit the EHC WF. 6.

display will show OK and the beeper will be on. BOTH LIMITS SET. LOW is set greater than HIGH The beeper will never sound and the display will show LO if the weight is less that the LOW limit, and HI if the weight is greater than the Low Limit. NOTE: The weight must be greater than 20 scale divisions for the check weighing to operate. To disable the Check-Weighing function enter zero into both limits by pressing the Clear key when the current limits are shown then pressing the Enter key to store the zero values Note: you can set high/low limit in all normal weighing, percentage weighing and counting mode. 4.8 Counting Mode Before beginning, tare the weight of any container that will be used, leaving the empty container on the scale. 1. To enter a piece weight by weighing a known quantity (calculate the piece weight): Place the samples on the scale, press the SPL key to begin. The scale will show "SPL. ---", use 0-9 keys to input the samples quantity (001-999), press the ENTER key to confirm. If you want to reset the value, press the Clear key to clear the value. Now put more weight on the scale, the display will show the number of parts (pcs). 2. To manually enter a known piece weight: Press PcWt key to enter piece weight entry mode. Use the number keys to input the known piece weight. Press the Enter key to confirm or press the ON/OFF key to exit this mode without storing the piece quantity. If you want to reset the value, press the Clear key to clear the value. Now put more weight on the scale, the display will show the number of parts (pcs). Press the % key to display unit weight (g/pcs), Total weight (kg) or the count (pcs). Press the FUNC key to return to normal weighing. NOTE: Sample piece weight should not be less than 0.5d, otherwise, scale will display LO.PC.WT, then back to normal weighing mode in 2s. 4.9 Percent Weighing Mode The scale will allow a sample weight to be shown as 1% - 100%. Then any other weight placed on the scale will be displayed as a percentage of the original sample. Press % key to enter percentage weighing mode, the display will show SPL.100%. Press 0 Press 1 Press 2 key to set to 1%, display shows SPL.001 key to set to 2%, display shows SPL.002 key to set to 5%, display shows SPL.005 EHC WF. 7.

Press 3 key to set to 10%, display shows SPL.010 Press 4 key to set to 20%, display shows SPL.020 Press 5 key to set to 50%, display shows SPL.050 Press 6 key to set to 100%, display shows SPL.100 Put weighing objects on the platter, then press Enter key to confirm. Remove the sample, and put another weight on the scale, it will display the percentage of the original sample. For example, if 6kg is placed on the scale and the % key is pressed the display will show 100.00%. Press Enter key. Removing the 6kg weight and putting a 3kg weight on the scale the display will show 50% as 3kg is 50% of 6kg. Press the FUNC key will return the scale to normal weighing mode. Note: if sampling weight is set to 1%, the weight must be more than 50d, if set to 2%, the weight must be more than 100d. The rest % need to be set in the same manner. 5.10 Mannual Accumulation Accumulation can be used in both weighing and counting modes. When the scale is set to manual accumulation the weight displayed will be stored in memory when the ACC key is pressed and the weight is stable. The display will show "ACC.01" and then the total in memory for 2 seconds before returning to normal. Remove the weight, allowing the scale to return to zero and put a second weight on. Press ACC, the display will show "ACC 002" and then show the new total, then show the total of the second weight Continue until all weights have been added. To view the totals in memory, press and hold the ACC key when the scale is at zero. The display will show the total number of items "ACC xxx" then the total weight before returning to zero. Note: In all cases the scale must return to zero or a negative number before another sample can be added to the memory. More product can then be added and ACC pressed again. This can continue for up to 99 entries, or until the capacity weight display is exceeded. 5.11 Automatic Accumulation When the scale has been set to Automatic Accumulation the value is stored in memory automatically (refer to setting in section 6). Put a weight to the scale, the beeper will sound when the scale is stable to signify the value is accepted, remove the weight, 2 seconds later the total symbol will be on, scale will show "ACC.01", then display the total value. Then total symbol will be off after 2s and back to weighing mode. Remove the weight, and add a second weight on the scale, repeat the process. To view the totals in memory, press and hold the ACC key when the scale is at zero. The display will show the total number of items "ACC xxx" then the total weight before returning to zero. EHC WF. 8.

4.12 Print (output) data via RS232 interface In normal weighing mode, when reading is stable, press Print key to output data via RS232 interface or USB interface: Gross: xxx.xxxkg/g/lb/oz Tare: xxx.xxxkg/g/lb/oz Net: xxx.xxxkg/g/lb/oz ACC.N: xxxxxxxxx Total: xxxxxxxxxkg/lb/oz In counting mode, when reading is stable, press Print key to output data via RS232 interface or USB interface: Gross: xxx.xxxkg Tare: xxx.xxxkg Net: xxx.xxxkg Pc.wt.: xxxx.xxg Count: xxxxxxxxxpcs ACC.N: xxxxxxxxx Total: xxxxxxxxxpcs In % weighing mode, when reading is stable, press Print key to output data via RS232 interface or USB interface: Gross: xxx.xxxkg Tare: xxx.xxxkg Net: xxx.xxxkg 100%.WT:xxx.xxxkg Precent: xxxxx.xx% 5. Calibration 5.1 Under the normal weighing mode,press and hold 1 and ON/OFF key until scale displays CAL. 5.2 Then scale displays Unit.KG or Unit.LB for the calibration unit choosing. 5.3 Use UNIT key to choose the calibration unit kg or lb (the corresponding unit indicator will be lighted on), use ON/OFF key to exit the mode, or ENTER key to confirm the unit and go to the next step. 5.4 The scale displays unload (this means that the scale is ready to calibrate the zero point, please move away any weight on the scale). When scale is stable, press ENTER key to confirm the zero point calibration and go to the next step automatically., or use ON/OFF key to exit the mode. 5.5 The scale displays Load 1,(this means the scale is ready to calibrate the first calibration point). Place a standard weight (>10% FS) on the center of the scale platter, press ENTER to confirm the standard weight calibration after the scale is stable and go to the next step automatically. Or use ON/OFF key to exit the calibration mode. 5.6 The scale displays InP.Ld (Input Load Weight), then displays 0, use 0-9 key and Clear key to input loaded standard weight, then press ENTER key for confirmation. Or use ON/OFF key to exit the calibration mode. 5.7 The scale displays Load 2,(this means the scale is ready to calibrate the second calibration point). Place a standard weight (> first calibration point weight + 10d) on the center of the scale platter, press ENTER to confirm the standard weight calibration after the scale is stable and go to the next step automatically. Or use ON/OFF key to exit the calibration mode. 5.8 The scale displays InP.Ld (Input Load Weight), then displays 0, use 0-9 key and Clear key to input loaded standard weight, then press ENTER key for confirmation. Or use ON/OFF key to exit the calibration mode. 5.9 The scale displays Load 3,(this means the scale is ready to calibrate the third calibration point). Place a EHC WF. 9.

standard weight (> second calibration point weight + 10d) on the center of the scale platter, press ENTER to confirm the standard weight calibration after the scale is stable and go to the next step automatically. Or use ON/OFF key to exit the calibration mode. 5.10 The scale displays InP.Ld (Input Load Weight), then displays 0, use 0-9 key and Clear key to input loaded standard weight, then press ENTER key for confirmation. Or use ON/OFF key to exit the CAL mode. 5.11 When the scale displays unload again, the scale is ready to re-confirm the zero point, move away any weight on the scale, press ENTER key to confirm. 5.12 After the calibration completes, the scale will re-initialize to be ready for normal weighing. Note: If there is an error occurred in calibration, the scale will display CAL.Er (this normally means incorrect data input or loading weight), please return back to the last step or use ON/OFF to exit the calibration mode. 6. Parameter Setup Mode 6.1 In normal weighing mode, press ON/OFF and 2 key until scale displays SETUP. 6.2 Then scale displays A.O.T xx, it means entering parameter setup mode. 6.3 In setup mode, use 0-9 key to input numbers, use Clear key to clear the input value, use ENTER key to confirm and go to the next parameter, use ON/OFF key to exit the mode. Parameter menu: Parameter meaning option Default setting A.O.T xx Auto off time setting 00~30 minutes 5 BLT. x blacklight 0 - Backlight always off 1 - backlight always on 2 - Auto auto on when key operation or weight changing; auto off if no operation in 15s 2 CST. x LCD contraction 0~7 4 level selection ACC.xxx Accumulation 0 - MAN, manual accumulation MAN BEEP.xx mode Beeper mode in check weighing mode 1 - AUT, auto accumulation 0-beeper always off 2 1-compare result is LO, beeper on 2- compare result is OK, beeper on 3- compare result is HI, beeper on BPS.xxx Baud rate 1200bps, displays as 12 2400bps, displays 24 4800bps, displays 48 9600bps, displays as 96 19200bps, displays as 192 DFT.xxx Byte format 1-8N1=8 data bits, No parity check bit, 1 stop bit; 2-7O1=7 data bits, 1 parity check bit, 1 stop bit; 3-7E1=7 data bits, 1 parity check bit, 1 stop bit; CFT. x Output mode 0-no communication 1-output after reading is stable 2-output after PRINT key is pressed 3-output after reading is stable or after PRINT key is pressed 96 1 2 EHC WF. 10.

7. Display and Key test 7.1 When power off, press ON/OFF key to power the scale on. When full capacity is displayed, press and hold CLEAR key until TEST is displayed, then release. 7.2 Use any key to test all segments of LCD 7.3 Display test: The LCD will be displayed as per the order F-G-E-D-A-B-C-P, pls watch and observe if any unusual. 7.4 Keypad test: It will automatically enter into keypad testing after the display test. Display KEY.---, press each key to display key value. Press ENTER key to enter into AD testing status. 7.5 AD test: Display inner code and observe if any unusual. For operation, please refer to 8. 7.6 Press ON/OFF key to exit the mode. 8. Display A/D code and working voltage 8.1 In normal working mode, press and hold ON/OFF and 3 key until scale displays CODE, then displays inner code (if inner code is bigger than 999999, it will display on two pages H xxxx and L xxxx). Press Unit key to display H xxxx, L xxxx or display both automatically. 8.2 Press TARE key to tare the inner code and display net inner code, NET symbol will be on. Press TARE key again to display the inner code and NET symbol will be off. 8.3 Press FUNC. key to check the working voltage, shows U.x.x (Voltage x.x V), this means the inner working voltage is x.x V. If the scale uses AC power adaptor, the voltage is the power adaptor voltage after regulating. If AC adaptor is not used, this around voltage is battery s voltage. EHC WF. 11.

9. Display symbol meaning Err01:weight is too big Err04:exceed zero range Err05:less than zero range Err12:parameter is not correctly set Err20:calibration error Err30:inner code is too big CAP.:capacity UOL.: voltage UNIT: measuring units UnLoAd:no loading LoAd:load weight INP.Ld:input loaded weight value EHC WF. 12.

10. Troubleshooting 10.1 Troubleshooting SYMPTOM PROBABLE CAUSE REMEDY Err01 Weight reading exceeds the overload limit or the weight value cannot be displayed in the current unit of measure. measure. Err04 Err05 Err30 Err10 Err12 Err20 Will not power on Unable to zero the display or will not zero when turned on Weight exceeds Power On Zero limit (+10%), or over ZERO key range (+10%). Weight is below Power On Zero limit (-5%) or below ZERO key range (-5%). Load cell wires to indicator are incorrectly connected, shorted, or open; or ADC, load cell are damaged. EEPROM is damaged. Setup parameters are not set, not correctly set, or settings have been lost. Calibration error. Input data or loaded weight is too small, too large, unstable, or not linear. Power cord not plugged in or properly connected. Power outlet not supplying electricity. Battery discharged. Other failure. Load on scale exceeds allowable limits. Load on scale is not stable. Load cell damage. Lo.bAt is shown Battery is discharged Charge battery Reduce load on scale until weight value can be displayed, or use an alternate unit of Make sure scale platform is empty. Power off scale and power on again. Perform zero calibration. Install platform on scale. Perform zero calibration. Make sure wires are correctly connected. Service required to replace load cell or ADC chip. Service required to replace main EEPROM IC chip. Re-set parameters. Perform calibration. Input correct data, load correct weight onto platform, or service is required. Check power cord connections. Make sure power cord is plugged into the power outlet. Check power source. Replace batteries. Or service required. Remove load on scale. Wait for load to become stable. Service required. 10.2 Battery and Charging Power is supplied by an internal rechargeable 6V lead-acid battery (4Ah). When Lo.bAt is displayed, the battery must be recharged. Plug in the AC power adapter to recharge the battery. The scale may continue to be used on AC power during charging. Full charging time is approximately 10-12 hours. Battery life and recharge time will vary with use. Over time, the operating time per each full charge will degrade. If the operating time is no longer acceptable, the battery must be replaced. When storing the scale for extended periods, the battery must be charged every 90 days to avoid premature performance degradation. EHC WF. 13.