Neon pr. ph/ ORP measurement. Applications. Description

Similar documents
Double-channel measuring and control instrument for free chlorine and ph-value - additionaly ORP optional

Power Meter PowerMonitor 500

SX90 Process Controller

Evolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors

Technical specification Marine Master Clock

Neon EC Neon EC IL CLEAR. CONTROL. CONNECT.

Control and automatic dosing

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

world class water monitoring series 42

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Type Multichannel Transmitter/Controller multicell for Flow and Analytical Sensors

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

Millenium II +: general characteristics

Pen Drive USB Datalogger!

APP 700 Technical Specification

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water

Energy Management Modular Energy meters Type EM2-96

Voltage Transducer UMT516 / MT516

Displays Transducers. Displays and transducers

MID approval no. DE-08-MI004-PTB004 Date of release

DTM Distributed Transmitter Monitor

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

mxcontrol Multifunction Controller

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Sensor for car parks and tunnels

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

N420 R420 R423. series

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

SINGLE-CHANNEL PROCESS INDICATOR series 8001

Neon DIS Krypton DIS CLEAR. CONTROL. CONNECT.

NF760 Batch Controller

DIGITAL INDICATING CONTROLLER

16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II

Technical Manual Nova: Cabinet Security Management System (CSMS)

LBVR1718. Description. Features channel paperless recorder

UNIVERSAL CURRENT CONVERTER

PXR Series Advanced Self-Tuning Temperature and Process Controllers

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

Andover ContinuumTM Infinet II

/8 DIN Motorized Valve Controller

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

KS5 SYNCHRONIZATION METER

Technical data sheets

Temperature/Process Controllers Manual

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

Stratos Pro A4 PH. Connection

User s manual. Programmable panel meter IPD

Measure & Control Temperature & CO2 levels with analog & digital I/O

THERMOSTATS & CONTROLLERS

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

SENSORLESS VECTOR CONTROL

LUMIOS MkIII Luminance Photometer for Tunnels

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters

MIC-2 MKII, Multi-instrument DATA SHEET

ISOMETER isoev425 with coupling device AGH420

MULTICHANNEL DATA RECORDERS

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

Faults on the system Proximity switch connection technology:

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

iologik 4000 Series (M) Modules

BACnet. b3810 Series Local Controllers

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Process Indicator Controller (Digital) (Product code 3.1 to 3.15)

PCM SLK- Series Inverter Specification

Features and Benefits. Certifications

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

with Backlight Graphic LCD Screen

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Multifunction Transducer MT440

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

Easy To Use OEMS Take Note

MPC / 6. First interface. distance up to 15m, speed up to 19,2Kbit/s, GSM modem support. 4 band 850/900/1800/1900 MHz

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

Technical data. Safety notes. Product features

RXTP ROOM TEMPERATURE

Transcription:

Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment Neon Touch wall mounted housing Description The Neon is a leading edge measurement and control instrument and its range of functions can be tailored according to your application. The entry level version contains input / outputs for measurement and temperature, key operation, a digital input, a alarm relay. The Neon is expandable through software upgrades and add on modules. It is possible to add up to two additional analogue outputs, control functions either concentration-based or volume-based, modbus interface and Datalogger. The information displayed on the screen can be selected by the user. With multiple installations the same settings within the software can be duplicated in additional instruments using industry standard SD cards. The new Neon 'Touch' is simplicity in a small package, it has an up to date touch screen to navigate through the Neon menus easily and intuitively. The Neon PR can be used for the measurement of ph and ORP.

Particular characteristics 85.. 265 V AC power supply 90x50 mm display - optional Touch Real time clock Automatic or manual temperature compensation Guided two point calibration Logging of the last 10 calibration data 2 limit values with delay, assigned to the alarm relay Alerts selectable for alarm relay Safety by autolock function Eventlog and event help Test menu for wiring check SD card function: firmware update, configuration and diagnosis file Power saving adjustable 2 user levels by password function Intuitive and easy menu Functional upgrade by activation code or with modules Option: 24 V DC Option: RS 485 - modbus RTU Option: 2 ma outputs 0/4 to 20 ma adjustable with fault current Option: 2 PID controller with 2 control relays Option: volume-based dosage with 2 control relays Option: 2nd digital input Option: data log function

Interface diagram Technical data Measuring parameter ph-value ORP -2.00.. +16.00 ph -1500.. +1500 mv Input characteristics Temperature measuring range -30.0.. +140.0 C Temperature coefficient Non-linear Digital input 1 as controller stop by external contact option: 2nd as controller stop or flow measurement for volume based dosing

Output characteristics Alarm relay Output signal Voltage output Storage media Serial interface 1 potential-free NO contact, max. 250 V, 6 A, 550 VA (invertable) Option: 2 x 0/4.. 20 ma (scaleable, galvanically isolated) Load 500 Ohm Registration range Scaleable within the measuring range +/- 6 VDC for impedance converter Accessory: SD card up to 2 MB - Industry standard Option: RS 485 - modbus RTU Baud rate 19200 bps Data format 8 bit Power supply Line voltage Power consumption 85.. 250 V AC, +6/-10%, 40.. 60Hz option: 24 V DC 10 VA Ambient conditions Temperature Storage -20.. +65 C Operation -5.. +50 C Humidity max. 90% rh at 40 C (non-condensing) Protection class Wall mounted IP 65 Panel mounted IP 54 (front), IP 30 (housing) Controller Control response Relay Start delay Controller stop Option: on/off controller (adjustable hysteresis) P/PI/ PID controller (pulse-pause, pulse-frequency or continuous output) servo motor control 2 relays, each with a potential-free NO contact, max. 250V, 6 A, 550 VA 0.. 200 sec until controller active Digital input Proportion to volume Control mode Option: volume based by flow measurement Flow measurement Impulse measurement NPN (by digital input 2) Flow measurement Engine speed 0.030.. 9.999 l/imp Relay 1 Potential-free NO contact, max. 250V, 6 A, 550 VA output of control variable as pulse frequency or pulse pause. Relay 2 Activating circulation pump Certificates and approvals CE-Symbol The product meets the requirements of the harmonized European standards and complies with the legal requirements of the EC directives. EMV/EMC EN 61000 6-1 (3) EN 61000 6-2 (4) EN 61326-1

Design configuration Material Dimensions Mounting dimension Weight Connection ABS Panel mounted housing: 138x138x83 mm; Wall mounted housing: 144x144x156 mm Panel mounted housing: 138x138x42 mm 0.6 kg (wall mounted housing: 1 kg) Cable inlet: 2x M16, 2x M12 + optional: 2x M12 and 1x M25 plug-in terminal: rigid /flexible 0.2-2.5 mm² / 0.2-2.5 mm² measurement rigid /flexible 0.2-1 mm² / 0.2-1.5 mm² Mechanical drawing Neon panel mounted

Neon wall mounted

Powered by TCPDF (www.tcpdf.org) Order information Choose the components you need and that s how your "assembly version" is designed. We will have to technically inspect and approve a free combination of individual key features.