Multidimensional Noise Reduction in C-arm Cone-beam CT via 2D-based Landweber Iteration and 3D-based Deep Neural Networks

Similar documents
Iterative CT Reconstruction Using Curvelet-Based Regularization

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Scaling Calibration in the ATRACT Algorithm

Separate CT-Reconstruction for Orientation and Position Adaptive Wavelet Denoising

Edge-Preserving Denoising for Segmentation in CT-Images

The Near Future in Cardiac CT Image Reconstruction

One Network to Solve Them All Solving Linear Inverse Problems using Deep Projection Models

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation

Total Variation Regularization Method for 3D Rotational Coronary Angiography

Patch-Based Color Image Denoising using efficient Pixel-Wise Weighting Techniques

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay

Image-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees

Image-based Compensation for Involuntary Motion in Weight-bearing C-arm CBCT Scanning of Knees

Total Variation Regularization Method for 3-D Rotational Coronary Angiography

Respiratory Motion Estimation using a 3D Diaphragm Model

Automatic Removal of Externally Attached Fiducial Markers in Cone Beam C-arm CT

Respiratory Motion Compensation for C-arm CT Liver Imaging

Quality Guided Image Denoising for Low-Cost Fundus Imaging

CoE4TN4 Image Processing. Chapter 5 Image Restoration and Reconstruction

Improved Non-Local Means Algorithm Based on Dimensionality Reduction

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

Optimizing the Deblocking Algorithm for. H.264 Decoder Implementation

Depth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences

Image Restoration Using DNN

Non-Stationary CT Image Noise Spectrum Analysis

CT Image Denoising with Perceptive Deep Neural Networks

DUE to beam polychromacity in CT and the energy dependence

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

IMAGE DENOISING TO ESTIMATE THE GRADIENT HISTOGRAM PRESERVATION USING VARIOUS ALGORITHMS

Int. J. Pharm. Sci. Rev. Res., 34(2), September October 2015; Article No. 16, Pages: 93-97

Accelerated C-arm Reconstruction by Out-of-Projection Prediction

Image Denoising Based on Hybrid Fourier and Neighborhood Wavelet Coefficients Jun Cheng, Songli Lei

Guided Noise Reduction with Streak Removal for High Speed Flat Detector CT Perfusion

ONE of the issues in radiology today is how to reduce the. Efficient 2D Filtering for Cone-beam VOI Reconstruction

Accelerated quantitative multi-material beam hardening correction(bhc) in cone-beam CT

MEDICAL IMAGE NOISE REDUCTION AND REGION CONTRAST ENHANCEMENT USING PARTIAL DIFFERENTIAL EQUATIONS

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

Optimization of Cone Beam CT Reconstruction Algorithm Based on CUDA

Central Slice Theorem

Digital Image Processing

Detecting Bone Lesions in Multiple Myeloma Patients using Transfer Learning

Towards full-body X-ray images

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Deep learning for dense per-pixel prediction. Chunhua Shen The University of Adelaide, Australia

Estimation of Missing Fan-Beam Projections using Frequency Consistency Conditions

Non-local Means for Stereo Image Denoising Using Structural Similarity

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

Make the Most of Time

Comparison of Default Patient Surface Model Estimation Methods

Detecting Salient Contours Using Orientation Energy Distribution. Part I: Thresholding Based on. Response Distribution

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

DEEP RESIDUAL LEARNING FOR MODEL-BASED ITERATIVE CT RECONSTRUCTION USING PLUG-AND-PLAY FRAMEWORK

Guided Image Super-Resolution: A New Technique for Photogeometric Super-Resolution in Hybrid 3-D Range Imaging

PRINCIPAL COMPONENT ANALYSIS IMAGE DENOISING USING LOCAL PIXEL GROUPING

Comparative Analysis in Medical Imaging

Image Processing

Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network

Single Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction

Denoising an Image by Denoising its Components in a Moving Frame

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

CT vs. VolumeScope: image quality and dose comparison

Digital Image Processing COSC 6380/4393

Single Image Super Resolution of Textures via CNNs. Andrew Palmer

Acknowledgments and financial disclosure

A Novel Image Super-resolution Reconstruction Algorithm based on Modified Sparse Representation

Edge and local feature detection - 2. Importance of edge detection in computer vision

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

DEEP LEARNING OF COMPRESSED SENSING OPERATORS WITH STRUCTURAL SIMILARITY (SSIM) LOSS

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

arxiv: v2 [cs.cv] 21 Dec 2018

Ch. 4 Physical Principles of CT

Super-resolution Reconstruction of Fetal Brain MRI

Respiratory Motion Compensation for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Whole Body MRI Intensity Standardization

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

GRID WARPING IN TOTAL VARIATION IMAGE ENHANCEMENT METHODS. Andrey Nasonov, and Andrey Krylov

A novel noise removal using homomorphic normalization for multi-echo knee MRI

A Novel Approach for Deblocking JPEG Images

Deep Scatter Estimation (DSE): Feasibility of using a Deep Convolutional Neural Network for Real-Time X-Ray Scatter Prediction in Cone-Beam CT

Research Article CT Image Reconstruction from Sparse Projections Using Adaptive TpV Regularization

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Enhancement Image Quality of CT Using Single Slice Spiral Technique

Frequency split metal artifact reduction (FSMAR) in computed tomography

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

PROCEEDINGS OF SPIE. Projection image-to-image translation in hybrid x-ray/mr imaging

An Iterative Approach to the Beam Hardening Correction in Cone Beam CT (Proceedings)

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Deep Learning Computed Tomography

Reduction of Metal Artifacts in Computed Tomographies for the Planning and Simulation of Radiation Therapy

Image Acquisition Systems

Spatial-temporal Total Variation Regularization (STTVR) for 4D-CT Reconstruction

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

arxiv: v1 [cs.cv] 11 Apr 2018

A New Orthogonalization of Locality Preserving Projection and Applications

Transcription:

Multidimensional Noise Reduction in C-arm Cone-beam CT via 2D-based Landweber Iteration and 3D-based Deep Neural Networks Dahim Choi 1, Juhee Kim 2, Seung-Hoon Chae 3, Byeongjoon Kim 4, Jongduk Baek 4, Andreas Maier 5, Rebecca Fahrig 6, Hyun-Seok Park 1, Jang-Hwan Choi 2 1 Computer Science and Engineering, Ewha Womans University, Seoul 03760, Korea; 2 Division of Mechanical and Biomedical Engineering, Ewha Womans University, Seoul 03760, Korea; 3 Electronics and Telecommunications Research Institute, Daejeon 34129, Korea; 4 School of Integrated Technology, Yonsei University, Incheon 406840, Korea; 5 Friedrich-Alexander University Erlangen-Nuremberg, Erlangen 91058, Germany; 6 Siemens Healthcare GmbH, Erlangen 91052, Germany ABSTRACT Recently, the necessity of using low-dose CT imaging with reduced noise has come to the forefront due to the risks involved in radiation. In order to acquire a high-resolution image from a low-resolution image which produces a relatively small amount of radiation, various algorithms including deep learning-based methods have been proposed. However, the current techniques have shown limited performance, especially with regard to losing fine details and blurring high-frequency edges. To enhance the previously suggested 2D patch-based denoising model, we have suggested the 3D block-based REDCNN model, employing convolution layers paired with deconvolution layers, shortcuts, and residual mappings. This process allows us to preserve the image structure and diagnostic features of an image, increasing image resolution by smoothing noise. Finally, we applied a bilateral filter in 3D and utilized a 2D-based Landweber iteration method to reduce remaining noise under a certain amplitude and prevent the edges from blurring. As a result, our proposed method effectively reduced Poisson noise level without losing diagnostic features and showed high performance in both qualitative and quantitative evaluation methods compared to ResNet2D, ResNet3D, REDCNN2D, and REDCNN3D. Keywords: deep neural networks, noise reduction, imaging of lower extremities, C-arm cone-beam CT, Landweber type iteration, bilateral filtering, medical image processing 1. INTRODUCTION The use of CT for diagnosis has increased rapidly and widely, and some patients in high-risk situations now need repeated scans to monitor their conditions. Meanwhile, as the deleterious effects of exposure to radiation have been uncovered, the potential risks of radiation have been brought to common awareness. One way to reduce radiation exposure to patients is to lower the dose of radiation administered in each CT scan. However, lowering the radiation dose increases noise in the image

and degrades image quality, which negatively affects the practitioner s ability to make an accurate diagnosis. Therefore, developing methods to obtain diagnostic-quality images from low-dose CT scans by implementing noise reduction techniques has become an undisputed necessity. To suppress noise in low-dose CT imaging, some state-of-the-art techniques utilizing Convolutional Neural Networks (CNN) including ResNet [1] and REDCNN [2] have been suggested [1, 3-7]. Image denoising methods based on deep learning have shown improved performance compared to conventional denoising algorithms such as BM3D [8], wavelet thresholding [9], wavelet multi-frame denoising [10], and Bayesian estimation denoising [11]. However, denoising with CNN architectures has the tendency to lose fine image details and blur out high-frequency edges. This is because the accumulated loss is not suitable for image reconstruction when the network goes deeper. In addition, when the network depth increases, the gradient diffusion makes the network difficult to train [2]. ResNet and REDCNN tried to overcome these problems by utilizing residual mapping. To further improve image quality, our research team proposed a multidimensional noise reduction algorithm in C- arm Cone-beam CT. We hypothesized that 3D block-based architectures may perform better than 2D patch-based architectures because the adjacent image slices in a CT volume have strong correlative features [12]. Therefore, we intended to improve performance by modifying the previously suggested 2D networks into 3D. Moreover, we applied a 3D bilateral filter and a 2D-based one-step Landweber-type iteration. In the research described in this paper, we have implemented ResNet and REDCNN in both patch-based and block-based models, and have compared the results with our proposed model. 2.1 Patient data acquisition 2. MATERIALS AND METHODS Under an IRB-approved protocol, 18 volunteers were imaged while lying supine using two different C-arm cone-beam CT systems (Artis Zeego and Axiom Artis dta, Siemens Healthcare GmbH, Forchheim, Germany) with a flat panel detector. The detector produced a matrix of 1240 960 pixels with 0.308 mm isotropic resolution after 2 2 binning. The acquisition protocol used the minimum allowed value of the kvp of 70, a detector dose request of 1.2 µgy/frame, and 496 frames over π plus fan angle in 20 seconds. Projection-specific values of mas and kv were modulated by a built-in automatic exposure control system [13]. The projection images were reconstructed in a 32-bit depth volumetric image of 512 voxels with an isotropic spacing of 0.5 mm using filtered back projection (FBP) using CONRAD [14]. The forward and backward projection processes were GPUaccelerated [15]. 2.2 Multidimensional noise reduction process 2.2.1 Noise reduction in 3D via CNN with 3D kernels REDCNN consists of encoder and decoder layers [2]. In encoder layers, there are two types of layers: convolutional layers and ReLU units. Similarly, decoder layers have transposed convolutional layers and ReLU units. Since the encoder and decoder should match up, REDCNN is composed of the same number of convolutional and deconvolutional layers. The network has shortcuts which connect the matching convolutional and deconvolutional layers, and both layers have the same kernel size. We used a 3 3 3 kernel size and a 32 32 32 block size, measured in pixels. Figure 1 shows that the patches went into the

network featuring the symmetry of paired convolution and deconvolution layers. The L 2 loss function was optimized by Adam [2]. The two subjects volumetric images were used as a test dataset to unbiasedly evaluate a final CNN model fit on the training dataset. The noisy low-dose images paired with the high-dose FBP-reconstructed images were generated by imposing Poisson noise into each voxel. Figure 1. Multidimensional noise reduction process. First, 3D blocks of low-dose CT imaging are sent through the REDCNN3D model. Then, the reconstructed outcome is filtered by a bilateral filter in 3D. With forward projection, the 2D result of denoised CT and filtered CT can be compared, and the difference contains information that we want to reduce or retain. 2.2.2 Noise reduction in 2D via a Landweber-type iteration Although the REDCNN3D network showed outstanding performance in Poisson noise reduction, reducing noise through the CNN network has the drawback of blurring the edges. In medical imaging, the edge is crucial for diagnosis because it contains information about lesions. Therefore, to deal with the edge-blurring problem and to smooth the remaining noise, we applied a bilateral filter to image voxel vector x, an outcome of the REDCNN3D network. Using a non-linear, bilateral filter allowed us to preserve the border line and decrease the Poisson noise level. Based on spatial distance (σ ) and radiometric differences (σ ), the filter smoothed noise below a certain intensity of amplitude. The radiometric differences (σ ) used in our method were determined by the intensity interval between fat and muscle, the minimum we want to conserve. Finally, we utilized the FDK algorithm [16] to create a 3D bilateral filtered image, thus implementing a Landweber-type reconstruction in one step [17]. The performance of the combination of bilateral filtering and Landweber iterations was similar with that of a total variation regularized iterative reconstruction [18], and the cost associated with the combination was relatively low. The whole process is described as follows: 1) Acquire REDCNN3D applied reconstruction CT image (x ). 2) Apply a 3D bilateral filter on voxel vector x with σ and σ. 3) Implement one step Landweber-type reconstruction using the following FDK algorithm: x x λa b Ax, where A is a forward-projector, A is a backward-projector, λ is a step size, and b is projected data in 2D. In this study, λ was determined as 0.7 heuristically.

2.3 Measurement of noise reduction and the line profile In order to assess the performance of each method, we measured the structural similarity index (SSIM) and noise level (% standard deviation) between a low-dose image (x ) and an outcome reconstructed image (x. Generally, SSIM is used to evaluate the similarity between two images and is designed to improve on traditional metrics such as peak-signal-to noise ratio (PSNR) and mean squared error (MSE) [19]. The closer the index is to 1, the better the performance of the model. We calculated the SSIM over the whole region of reference in the testing images, including the standard deviation over the space between the legs. We also measured the intensity across the border between fat and muscle, and the boundary between cortical bone and fat, as indicated by the arrows in Fig. 3(a). 3.1 Qualitative evaluation 3. RESULTS Representative reconstructed slices of the test dataset of two healthy subjects are displayed in Fig. 2. In this study, the main causes of the low-frequency background noise in the low-dose images were found to be the Poisson noise imposed and limitations of a standard FBP reconstruction. As the arrows in the low-dose images (a4 and a5) indicate, severe background noise appeared like a white band especially around the central region in the sagittal plane which degraded soft tissue visibility. Between REDCNN3D (e5) and ResNet3D (c5), REDCNN3D reduced the background noise better. When comparing the performance of 2D and 3D models, REDCNN3D (e5) better suppressed the noise than REDCNN2D (d5). Among all the methods tested, the proposed method (f5) showed the best performance, suppressing the noise almost completely to the noise level in the reference image (g5). As the arrows in e3 and f3 indicate, streak artifacts and the background noise present in REDCNN3D were effectively suppressed when using the proposed method. The pattern of the performance difference of the method mentioned above was relatively clear in the fourth and fifth rows (a-g4 and a-g5) of a sagittal plane, but similar patterns were found in other rows.

Figure 2. The left and rightmost columns in the figure show the noisy low-dose input (a) and reference (g), respectively. The remaining columns correspond to images processed with ResNet2D (b), ResNet3D (c), REDCNN2D (d), REDCNN3D (e), and the proposed method (f). To better appreciate the differences in image quality, it is recommended to magnify the images as much as possible. 3.2 Quantitative evaluation Representative line profiles of the low and high contrast edges are shown in Fig. 3, and they were extracted from the same subject data as in Fig. 2. The current state-of-the-art denoising method, REDCNN2D, was not capable of recovering edges with low contrast well, as seen with its line profiles showing the noise-like fluctuation and the Hounsfield unit (HU) values of fat that did not decrease even after passing through the muscle-fat edge (see Fig. 2[b]). In contrast, the line profiles of 3D block-based REDCNN3D confirmed that in this method, edges with low contrast were reconstructed well without degrading spatial resolution. As seen in Fig. 3(b-c), the proposed method achieved even sharper line profiles over both the weak and strong edges by reducing artifacts and noise in the uniform area of low density material (fat), indicated by the magnitude of the first peaks on the right side of the solid vertical line.

(a) Region of interest (ROI) for line profiles in (b) and (c) (b) Line profiles over the weak edge in (a) (c) Line profiles over the strong edge in (a) Figure 3. Comparison among the line profiles of noisy input, reference, and images processed with three correction methods over the weak edge and strong edge marked on (a). (a) Line profiles ROI in central slice. (b) The line profiles of the weak edge across muscle and fat. (c) The line profiles of the strong edge across bone and fat. As observed qualitatively, the proposed method showed the best performance, achieving the highest SSIM (see Table 1). The proposed algorithm suppressed noise by approximately 24% compared with the noisy input image (82% 58%). This noise reduction was enabled by the edge-preserving property of a bilateral filter preserving edges over the threshold level (σ r ). SSIM [0-1] Noise, σ [HU] Noisy input (low-dose) 0.7737 (±0.0493) 82.52 (±2.94) ResNet2D 0.8667 (±0.0027) 72.15 (±3.17) ResNet3D 0.9233 (±0.0026) 65.58 (±2.70) REDCNN2D 0.8954 (±0.0019) 58.56 (±2.95) REDCNN3D 0.9258 (±0.0021) 65.58 (±2.91) Proposed method 0.9399 (±0.0023) 58.73 (±3.14) Table 1. Quantitative results in terms of image quality (the SSIM) and the background noise (the standard deviation [σ] of the background intensity) in HU. The results are associated with different algorithms. 4. CONCLUSIONS Denoising with current CNN architectures has the tendency to lose fine image details and blur out a high-frequency edge. In this research, we overcame these problems using the proposed multidimensional noise-reduction algorithm working on both the 2D projection and the 3D image domains incorporating a Landweber-type iteration in 2D and a volumetric block-based CNN architecture in 3D into one step. The newly proposed method suppressed background noise effectively and also reduced streak artifacts while preserving fine spatial resolution. The proposed method showed better performance both qualitatively and quantitatively than current state-of-the-art CNN denoising models including ResNet and REDCNN.

ACKNOWLEDGEMENT This research was supported by the National Research Foundation of Korea (NRF) grant funded by the Korean government, MSIP (grant no: NRF-2015M3A9A7029725 and NRF-2017M2A2A6A02070522, URL: http://nrf.re.kr). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. This work was never submitted, published, or presented before. REFERENCES [1] K. Zhang, W. Zuo, Y. Chen et al., Beyond a gaussian denoiser: Residual learning of deep cnn for image denoising, IEEE Transactions on Image Processing, 26(7), 3142-3155 (2017). [2] H. Chen, Y. Zhang, M. K. Kalra et al., Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network, IEEE Trans Med Imaging, 36(12), 2524-2535 (2017). [3] C. Dong, C. C. Loy, K. He et al., "Learning a deep convolutional network for image super-resolution." 184-199. [4] L. Gondara, "Medical image denoising using convolutional denoising autoencoders." 241-246. [5] X. Mao, C. Shen, and Y.-B. Yang, "Image restoration using very deep convolutional encoder-decoder networks with symmetric skip connections." 2802-2810. [6] T. Würfl, F. C. Ghesu, V. Christlein et al., "Deep learning computed tomography." 432-440. [7] T. Wurfl, M. Hoffmann, V. Christlein et al., Deep Learning Computed Tomography: Learning Projection-Domain Weights From Image Domain in Limited Angle Problems, IEEE Trans Med Imaging, 37(6), 1454-1463 (2018). [8] K. Dabov, A. Foi, V. Katkovnik et al., "BM3D image denoising with shape-adaptive principal component analysis." [9] F. Luisier, T. Blu, and M. Unser, A new SURE approach to image denoising: Interscale orthonormal wavelet thresholding, IEEE Transactions on image processing, 16(3), 593-606 (2007). [10] M. A. Mayer, A. Borsdorf, M. Wagner et al., Wavelet denoising of multiframe optical coherence tomography data, Biomedical optics express, 3(3), 572-589 (2012). [11] E. P. Simoncelli, [Bayesian denoising of visual images in the wavelet domain] Springer, (1999). [12] H. Shan, Y. Zhang, Q. Yang et al., 3D convolutional encoder-decoder network for low-dose CT via transfer learning from a 2D trained network, arxiv preprint arxiv:1802.05656, (2018). [13] M. Soderberg, and M. Gunnarsson, Automatic exposure control in computed tomography--an evaluation of systems from different manufacturers, Acta Radiol, 51(6), 625-34 (2010). [14] A. Maier, H. G. Hofmann, M. Berger et al., CONRAD--a software framework for cone-beam imaging in radiology, Med Phys, 40(11), 111914 (2013). [15] H. Scherl, B. Keck, M. Kowarschik et al., [Fast GPU-based CT reconstruction using the common unified device architecture (CUDA)], (2007). [16] L. A. Feldkamp, L. C. Davis, and J. W. Kress, Practical Cone-Beam Algorithm, Journal of the Optical Society of America a- Optics Image Science and Vision, 1(6), 612-619 (1984). [17] L. Landweber, An iteration formula for Fredholm integral equations of the first kind, American journal of mathematics, 73(3), 615-624 (1951). [18] M. T. Manhart, M. Kowarschik, A. Fieselmann et al., Dynamic iterative reconstruction for interventional 4-D C-arm CT perfusion imaging, IEEE Trans Med Imaging, 32(7), 1336-48 (2013). [19] A. Hore, and D. Ziou, "Image quality metrics: PSNR vs. SSIM." 2366-2369.