No longer for sale. Generator Controller GC-1. Data sheet. Standard functions

Similar documents
Generator Controller GC-1

Engine Controller EC-1

Generator Controller GC-1F

DATA SHEET Genset Controller, GC-1F

SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions

Basic Gen-set Controller multi-line F SW version 2.31.X or later

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

AGC 200 Advanced Gen-set Controller DATA SHEET

Generator Protection Unit, GPU-3 DATA SHEET

Automatic Gen-set Controller Multi-line D

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

Generator Protection Unit, GPU-3 DATA SHEET

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

Generator Paralleling Controller, GPC-3 DATA SHEET

PPM Protection and Power Management DATA SHEET

Genset Controller Unit Model EMS - GC10. Installation Manual Section

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

AGC 200 Automatic Advanced Gen-set Controller DATA SHEET

DATA SHEET Compact Genset Controller, CGC 200

INSTALLATION INSTRUCTIONS

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

DATA SHEET Paralleling and Protection Unit, PPU-3

Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

DATA SHEET IOM 200 analogue interface for AGC 200

Installation Manual. Multi Power Controller MPC-1 multi-line D

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Genset Controller, GC-1F

DATA SHEET Automatic Genset Controller, AGC-3

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

PPU Power Management (PPM)

Multiple Generator Automatic Synchronising System

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management

INSTALLATION INSTRUCTIONS

Genset control and protection with safety system

Delomatic 4, DM-4 Marine & Offshore DATA SHEET

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Delomatic 4, DM-4 Land DATA SHEET

Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring

Engine & Genset Controls Z, page 1 of 12

DATA SHEET Automatic Genset Controller, AGC-4

MIC-2 Multi-instrument DATA SHEET

Comprehensive Modular Genset Controller

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

InteliNano NT. MRS Lite GEN-SET CONTROLLER. Description. Benefits

NOT RECOMMENDED FOR NEW DESIGNS

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

Compact Genset Controller, CGC 200 Mounting Terminals and wiring Commissioning, using the Utility Software and/or the front panel

HMC9000A DIESEL ENGINE CONTROLLER (With J1939 Interface) USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD.

DATA SHEET Selectable AC transducer, TAS-321 DG

APC715 Pump Unit Controller USER MANUAL. Smartgen Technology

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

HGM9510 Genset Parallel (With Genset) Unit USER MANUAL. Smartgen Technology

InteliLite MRS17 Click Here to Learn More

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Comprehensive Modular Genset Controller

DELOMATIC - MULTI-FUNCTION SYSTEM PART 2 INSTALLATION INSTRUCTION

Product Description. Contents. Fusion Series. New Information December 2003

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

DATA SHEET Selectable AC transducer, TAS-331DG

HGM7200/HGM7100A Series Automatic Genset Controller User Manual Smartgen Technology

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

DATA SHEET Advanced Graphical Interface, AGI 100 series

Micro Contactor MA Series

MIC-2 MKII, Multi-instrument DATA SHEET

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

PGR-3200 MANUAL INSULATION MONITOR

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

DEIF A/S. Description of options. Option C2, Generator add-on protection package Automatic Gen-set Controller. Description of option

HGM9520 Genset Parallel (With Mains) Unit USER MANUAL. Smartgen Technology

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

InteliNano NT GEN-SET CONTROLLER. Description. Benefits MEMBER

100% electricity. Automatic transfer switch controllers ATL series

Engines & Gen-sets N, page 1 of 6

HT-DST4602 Evolution. Genset Controller. AMF and PARALLEL genset controller. Parallel Applications HUEGLI TECH SWITZERLAND

QUICK START GUIDE Paralleling and Protection Unit PPU 300

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Digital Clamp-on Meter Amp Plus. Instruction Manual

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Digital Clamp-on Meter Instruction Manual

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Digital Clamp-on Meter Amp Plus. Instruction Manual

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Option H3 Serial communication Profibus DP

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

GC2000 Generator Controller Power Management and Protection

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Circuit Breaker Analyzer & Timer CAT65

Transcription:

4921240293F DEIF A/S Engine control Start preparation (preheater or prelubrication) Start/stop sequences with selectable no. of start attempts Fuel solenoid selection (coil type) Idle speed control Local or remote start/stop Stop sequence with cool-down Running speed detection selectable o Charger alternator input (W terminal) or tacho generator o Binary input (D+) o Oil pressure based run detection o Voltage/frequency Generator monitoring 3 or 1-phase generator monitoring o Voltage/current/frequency/ power/reactive power Generator protection (ANSI) Over-/undervoltage (27/59) Over-/underfrequency (81) Overcurrent (51) Reverse power (32) Standard functions Engine monitoring 3 configurable inputs o VDO or o 4-20 ma from active transducer or o Binary with cable supervision 6 binary inputs, configurable RPM input, selectable o Magnetic pick-up o NPN or PNP pick-up o Tacho generator o Charger alternator W terminal Clear text display 122 x 32 pixel backlight STN Graphic symbol messaging Clear text alarm messages Clear text diagnostics for both hardwired inputs and CANbus messages (J1939) Log book holding 30 log entries Real time clock for time and date DEIF A/S

Application The is a micro-processor based control unit containing all necessary functions for protection and control of a diesel engine. Furthermore, it contains a three-phase AC voltage measuring circuit. The unit is equipped with an LCD display presenting all values and alarms. GC-1 is a compact all-in-one unit designed for the following applications: 1. Automatic engine start/stop 2. Engine protection 3. Breaker control 4. Generator protection Optional applications: 5. Automatic Mains Failure 6. CANbus J1939 engine communication GC-1 automatically carries out a cyclical self test. If any errors are found, then the status relay output will deactivate (normally closed). In order to save battery power, the display can be set to switch off automatically after a given period of time. Terminals Terminal Technical data Description The display will turn on again, if events or alarms take place, or if one of the push-buttons is activated. Setup Setup is easily done via a PC Windows based utility software (password protected) using the RJ11/RS232 PC connection. The PC interface box RJ11/RS232 needed for this operation is optional equipment for GC- 1. The PC utility software offers additional features such as monitoring of all relevant information during commissioning, saving and downloading of settings and downloading of software updates. Furthermore, the most frequently used settings can be accessed via the display push-buttons (password protected). Options The options selected by the customer will be integrated in the standard GC-1 hereby securing the same user interface unaffected by whether the application needs a basic or a more complex generator controller. 4 Common for terminals 5-7 5 VDO1, 4..20 ma, dig. inp. Fuel level/configurable 6 VDO2, 4..20 ma, dig. inp. Oil pressure/configurable 7 VDO3, 4..20 ma, dig. inp. Water temp/configurable 8-9 Tacho input Magnetic pick-up/pnp/npn/tacho generator/charge alternator W terminal 10-11 Status out, 1A 30V DC/V AC General status output for marine approvals 12 Common Common for term. 13-18 13 Digital input term. 13 Start enable/configurable 14 Digital input term. 14 Remote start/configurable 15 Digital input term. 15 Charge alternator D+ (running)/configurable 16 Digital input term. 16 Overspeed/configurable 17 Digital input term. 17 Coolant temperature/configurable 18 Digital input term. 18 Oil pressure/configurable 23 Common Common for term. 24, 25 and 32 and emergency stop* 24 NO relay output 1, 2A 30V DC/V AC Horn 25 NO relay output 2, 2A 30V DC/V AC Alarm/configurable 26 Power supply (gnd) 27 Power supply + 6 36V DC 28-31 Not used 32 NO relay output 3, 2A 30V DC/V AC Start prepare/configurable 33-34 NO relay output 4, 8A 30V DC/V AC Run coil/stop coil/configurable 35-36 NO relay output 5, 8A 30V DC/V AC Starter (crank)/configurable 37 Generator L3 voltage 38 No Generator neutral voltage 39 Generator L2 voltage Voltage range 50-480V AC Ph-Ph value 41 Generator L1 voltage 49-50 Generator breaker control relay, 2A 30V DC/V AC 53 I L3 s1 Generator current L3 54 I L3 s2 55 I L2 s1 Generator current L2 56 I L2 s2 57 I L1 s1 Generator current L1 58 I L1 s2 longer for sale DEIF A/S Page 2 of 8

43 Mains L3 voltage 45 Mains L2 voltage 46 Mains neutral voltage 47 Mains L1 voltage Optional AMF control 51-52 Mains breaker control relay, 2A 30V DC/V AC Configurable 1 CAN-L 2 CAN-GND 3 CAN-H Optional CANbus engine interface Available options Voltage range 50-480V AC Ph-Ph value CAN J1939 engine communication Option Description Type Note B Generator protection H J K B3 H5 Automatic Mains Failure - Generator and mains breaker control - Change-over (no synchronisation) Communication CANbus J1939 - Detroit Diesel DDEC - John Deere JDEC - Deutz EMR - Volvo Penta D12 AUX - Scania DEC Cables Software option Software option J5 PI-1 converter box kit (for PC connection) Hardware option Documentation K1 Installation Instructions and Reference Handbook (hard copy) Other K2 CD-ROM with complete documentation Other L Gasket for IP54 Hardware option (ANSI# as per IEEE Std C37.2-1996 (R2001) in parenthesis). Option B3 display layout DEIF A/S Page 3 of 8

Wiring, engine interface F: Fuse: 2A slow-blow. H5 Charging alternator D- D+ Running 1N4007 VDO 3 VDO 2 VDO 1 Starter RUN coil Start prep. Alarm Alarm Horn Emer. STOP Battery + Rex Status F Engine communication Can H Com Can L 3 2 1 Multi-functional inputs VDO sensors 7 6 5 4 Tacho input Magnetic pickup/ Tacho generator 9 8 GC-1 15 36 35 34 33 32 25 24 23 11 10 27 26 R5 R4 R3 R2 R1 3 2 1 Multi-functional inputs 4-20 ma transmitters + + + - - RJ11 plug 18 17 16 15 14 13 12 Converter Oil pressure Coolant temp Overspeed Spare* Remote start Start enable Programming tool 7 3 2 R 6-1 5 R 4 R + R= 100 Ohm Tacho input NPN/PNP pickup +24 VDC C out 9 8 *: Term.15 is shown as D+ input If D+ is not used term. 15 can be used for other purposes Rex: 12V systems: 47 Ohm 2W 24V systems: 100 Ohm 2W Multi-functional inputs Binary input w. cable superv. Tacho input W input from charger alternator 7 6 5 4 B+ W C 9 out B+ 8 C= 1µF/100V foil type C= 1µF/100V foil type DEIF A/S Page 4 of 8

Wiring, AC interface Connection of the 3-phase voltage and current The AC current grounding can be made as required to s1 or s2. GB: Use a contactor. The ON output from the GC-1 is a constant signal. Remember to use free-wheel diodes across the contactor coils, if DC voltage is used as supply for these. Fuse for AC voltage: Max. 2A slow-blow. DEIF A/S Page 5 of 8

Wiring, AMF (option B3) The AC current grounding can be made as required to s1 or s2. GB and MB: Use contactors. The ON outputs from the GC-1 AMF are constant signals. Remember to use free-wheel diodes across the contactor coils, if DC voltage is used as supply for these. Fuse for AC voltage: Max. 2A slow-blow. DEIF A/S Page 6 of 8

Accuracy: Class 2.0 to EN 60688/IEC 688 Operating temp.: (UL/cUL Listed: Storage temp.: Measuring input voltage: (UL/cUL Listed: Load: Frequency: Measuring input current: Consumption max.: Current overload: (UL/cUL Listed: Pickup input voltage: Frequency: Aux. supply: (UL/cUL Listed: Passive binary in voltage: Impedance: VDO inputs: Analogue input: Current: Impedance: -25 70 C (-13 158 F) Max. ambient temp. 40 C/104 F) -40 70 C (-40 158 F) 50 550V AC phase to phase 50 300V AC) 1.5 M 30 70 Hz 1 or 5A AC from current transformer 0.3 VA/phase 10A continuously, 20A, 5 sec. Use listed or R/C (XODW2.8 current transformers)) 0.5 70 V peak 10-10000 Hz 6-36V DC continuously 12/24V DC) Max. 8 W consumption Bi-directional optocoupler 8 36V DC 4.7 k Resistor inputs, internal 4 V supply From active transducer 4 20 ma 50 Active binary in internal voltage: Dry contact inputs (note 1) 4V DC supply, with cable supervision Impedance: 240 ~ 16 ma Only 3 inputs are available. Technical specifications Relay outputs: 5 relays: 30V DC/AC 2A (UL/cUL Listed: 30V DC 2A resistive) 2 relays: 30V DC/AC 8A (UL/cUL Listed: 30V DC 4A resistive) 1 status relay: 24V DC 1A (UL/cUL Listed: 24V DC 1A) Mounting: Panel mounted Size: 78 x 106 mm (3.07 x 4.17 ) Climate: 25 70 C to IEC 60068-2-1/2 97% RH to IEC 60068-2-30 Display: Safety: Protection: 122 x 32 pixel backlight STN To EN 61010-1, installation category (overvoltage category) III, 600 V, pollution degree 2 Front: IP52 (IP54 with gasket, option L) Terminals: IP20 To IEC 529 and EN 60529 EMC/CE: To EN 61000-6-1/2/3/4 SS4631503 (PL4) and IEC 255-3 Material: Plug connections: PC connection: All plastic materials are selfextinguishing according to UL94 (V1) AC voltage inputs: 3.5 mm 2 multi-stranded AC current inputs: 4.5 mm 2 multi-stranded Other: 1.5 mm 2 multi-stranded RS232 converter box (option J5) Approval: UL/cUL to UL 508 Weight: UL markings: Wiring: Terminal tightening torque: Mounting: Installation: Approx. 0.9 kg (1.9 lbs) Use 60/75 C copper conductors only AWG 30-12 It is possible to combine VDO inputs with binary and 4 20 ma inputs in a mix. 5-7 lb-in For use on a flat surface of a type 1 enclosure To be installed in accordance with the NEC (US) or the CEC (Canada) DEIF A/S Page 7 of 8

Unit dimensions in mm (inches) 106mm (4.17 in) 78mm (3.07 in) 140mm (5.51 in) 10mm (0.39 in) GC-1 Option Option TEMP 120h 90mm (3.54 in) 34 C 11.0 66.5mm (2.62 in) Order specifications 55.0 Panel cutout H x W = 68 x 92 +0.3 mm H x W = 2.68 x 3.62 +0.01 DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark Due to our continuous development we reserve the right to supply equipment which may vary from the described. Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: deif@deif.com, URL: www.deif.com