VersaPrint Operator s Manual

Similar documents
P1322 Operator s Manual

Library Vault Operator s Manual

AM8074 User s Manual

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

User Manual. Thermo Scientific Orion

Table of Contents.

Mott Community College

PhotoPDF User Guide. PhotoPDF. Photo to PDF Converter

INSTALLING THE PS3 XBOX READY SOFTWARE:

C75/J75 Simple Image Quality Adjustment (SIQA) v2.0 Software Installation Instructions

Abila MIP DrillPoint Reports. Installation Guide

Alpha-Numeric Display Pager MODEL :AL-A28. Gold Apollo Co., Ltd.

Sage Fixed Assets Lite Depreciation

Sage Fixed Assets Single User

BenchMike - NMS Operator s Manual

Reno A & E, 4655 Aircenter Circle, Reno, NV (775) Release Date: February 5, 2008 All Reno A&E monitors. All versions of RaeComM.

BitLocker Drive Encryption Guide

TM Printer Service and Support Utility for Windows Version 2.xx User s Manual (English)

Sage Fixed Assets Single User. Installation guide

VSM Manager. The VSM Manager is a Windows GUI that can be installed to serially control Genesis Matrixes with a firmware of version 2.5 or later.

Storing a Scan to a Folder

User manual. «Parking RFID ver. 2.0» Fresh USA, Inc. 707 Skokie blvd. Suite 600,

RELAY TIMER R8X. V2.5 Software Tutorial. Ginkgo LLC. Serial Port & Network Communication Software

ProtoCOL 3 Software Installation - Quick Guide

Installing ProjectSpec from the ProjectMatrix DVD

Setting up the PC ready for BESA 11

Optimizer Collect User Manual. for MFC/MFM calibration with Integrator 110 and Drycal

PROGRAMMING INSTRUCTIONS

PT Data Management Software User s Guide

DEPOSITPARTNER INSTALLATION GUIDE Desktop Application

ALMS Desktop Application User Manual

Pursuit 7 for Windows

Sage Fixed Assets Lite Depreciation. Quick start guide

CipherLab Workstation Setup (Windows 7/8/10)

Created December 2008

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.

Personal Radiation Detectors Data Collection and Processing Software User Guide

Installing FileMaker Pro 11 in Windows

PropertyBoss Upgrade

Newage hardness testing

Configuring the Switch

WLAN MIERUZZO BASIC SOFTWARE

Table of Contents.

Configuring the Switch with the CLI Setup Program

STATISTICA VERSION 10 STATISTICA MONITORING AND ALERTING SERVER (MAS) INSTALLATION INSTRUCTIONS

Installation instructions for the PARTNER TECH PT 6215 Hardware with Corner Store POS

Manual for User PTTEP EXTRADRIVE

User Manual. MPPTracker. Management Software for Solar Charge Controller. Version: 1.2

PAS. Installation Guide. BG0608 Rev. A1. Copyright SATEC Ltd.

Procomm Plus Installation Guide. Prophet 21 FASPAC 4.1

CCC ONE Comp-Est. Reference Guide for Upgrading to CCC ONE Comp-Est. version 4.2 and above

Installing VersaWorks on Windows Vista and Windows 7 Follow the steps below to install VersaWorks on Windows Vista or Windows 7:

How to install the software of ZNS8022

SolarPower Pro. User s Manual. Management Software for Solar Inverter

Software Package Installation Instructions

Instructions for Communicating with AMS Suite: Machinery Health Manager 5.0 Using the CSI 2130 Machinery Health Analyzer

Batch Watermark Creator Software

USB driver and Software Installation. UPS Monitoring and Management Software

Historical Viewer. ETC5000 User manual 312/15

Expert PR Taxes User s Manual Payroll November p f P.O. Box San Juan PR

PC Agent Quick Start. Opening the Agent. Logging in to the Agent. Connected Backup. Version 8.6. Revision 0

Dell Streak Unlock Software

ModeChanger

HOW TO: Upgrade Windows XP to Windows 7 with Windows Easy Transfer

INSIGHT Installation Instructions

Bluetooth Micro Dongle User s Guide. Rating: 5V DC 80mA Made in China

Celadon Password Self-Service

i-weight - Acquistion and Statistics analysis Software for Balances Software version 2.0 (V8) User Manual

Sage Fixed Assets Network

WINARTU3. Windows BHT Communications Utility. Installation & User Guide

CCC ONE Total Claims Solution. New Install and Set Up Reference Guide. version and above

TS MANAGER OPERATIONS MANUAL

1320 Electronics LLC USB-ALDL Cable User s Guide Electronics LLC. User s Guide for: USB-ALDL Cable

RTE for WIN32. Installation Manual (Rev.7.0) Midas lab

Setup Smart Login for Windows V2

CCC ONE Appraisal Platform

Metasys Export Utility Installation Instructions Code No. LIT Software Release 9.0 Issued August 2017

Device Set-Up. User s Guide

Boxed messages as shown below need your special attention. Read them carefully.

Installation and Programming Instructions Part: Service Gateway

CITO2 Installation & User Instructions

INST.NO. INE-919. DI5000 Setting Software

PV101-C Configuration Software V3.2. Installation and Operations Manual Section 78

Upgrade EZ-Pay V6 Guide

Document Management Upgrade Guide

Instruction for data transfer via data export software for QUANTOFIX Relax

WorldShip Install on a Single or Workgroup Workstation

CCC ONE Comp-Est. New Install Reference Guide. version 4.5 and above

DT-CONFIG SOFTWARE USER S MANUAL

Smart Flash Drive SecurePRO User Manual. Version_010

Data Capture System for Windows. Documentation. TSW Automation, Inc Robertson Ave. Nashville, TN phone: fax:

MESURgauge Software. User s Guide

OUTLOOK ATTACHMENT EXTRACTOR 3

JANOME ELECTRO PRESS. Operation Manual. <PC Operation>

Océ Account Center. User manual

USB 598. Quick Start Guide. USB Modem With.

Upgrading and Networking SK 7

LE840/LE850. Printer Setting Tool Manual Technical Reference

GP-N100 Utility Software Manual

V-STATS 4.01 HB g Copyright: SenTec AG. Installation Manual. for V-STATS with. V-CareNeT Package. Copyright:

Transcription:

VersaPrint Operator s Manual BadgerWare, LLC PO Box 292 Dayton, OH 45409 877.298.3759 www.badgerware.net

Table of Contents Section 1: Introduction... 1 Section 2: VersaPrint Main Window... 4 Section 3: System Setup... 6 Section 4: Configure COM Port... 7 Section 5: Security... 8 Section 6: Batch Reports... 9 BadgerWare, LLC Table of Contents

Section 1 Introduction Introduction The VersaPrint software collects individual measurement values from the serial port (or USB serial adapter) on a PC (running Windows XP, Windows Vista, or Windows 7) for batch reporting. Reports are printed automatically when the timeout period is reached or manually upon clicking the Print button. Installation To install the VersaPrint software, run the installation program named VersaPrint Setup.exe. A folder will be created on the C: drive named C:\VersaPrint and the executable file (VersaPrint.exe) and a PDF of the manual (VersaPrint.pdf) will be copied to that folder. Also, a shortcut to the executable file will be placed on the Windows desktop. To run VersaPrint, use the shortcut on the Windows desktop, click Run on the Windows Start Menu and select C:\VersaPrint\VersaPrint.exe, or double click C:\VersaPrint\VersaPrint.exe from within Windows Explorer. Running VersaPrint for the First Time The first time VersaPrint is run, communications with the measurement gauge are defaulted to OFF and the communication parameters are defaulted to 9600 baud, no parity, 8 data bits, and 1 stop bit. Be sure to match the serial port configuration of the measurement gauge (refer to the gauge s Operator s Manual) to the communications settings of VersaPrint. Measurement Gauge Configuration In addition to matching the communications settings of the measurement gauge to those of VersaPrint, the measurement gauge must be configured to transmit a single data value terminated by a carriage return at the completion of each measurement. BadgerWare, LLC Page 1 of 9

Registration The VersaPrint software must be registered for use on each computer on which it is installed. Until registration is complete and the unlock code has been entered, the registration form will be displayed each time VersaPrint is run. Additionally, although measurement values will be displayed within VersaPrint, they will not be exported to the external windows program (e.g. Excel). To register, complete the form and click OK. A file named VersaPrint.rgs will be created in the VersaPrint directory. Attach the VersaPrint.rgs file to an e-mail message and send to register@badgerware.net. An e-mail response containing the unlock code (for that particular computer) will be sent within 24 hours. The actual response time will usually be much less than 24 hours depending on what time of day (Eastern Time) the registration is received. Click Cancel to postpone registration and close the form without creating the VersaPrint.rgs file. To redisplay the form without having to restart the program, click Registration on the VersaPrint Menu. BadgerWare, LLC Page 2 of 9

To display the Unlock window, click Unlock on the VersaPrint Menu. To unlock the software, enter the unlock code received in the registration e-mail response and click OK. Click cancel to close the window without attempting to unlock. BadgerWare, LLC Page 3 of 9

Section 2 VersaPrint Main Window Menu To access the VersaPrint Menu, click Menu in the upper left hand corner of the Main Window. System Setup Report Folder Security COM Port Exit About Click System Setup to display the System Setup window. Click Report Folder to select a folder where report files are to be saved. Click Security to enable or disable security. When security is enabled (indicated by a check mark), changes to the VersaPrint configuration are not allowed. Click COM Port to display the Configure COM Ports window. Click Exit to exit from VersaPrint. Click About to display the VersaPrint version information. BadgerWare, LLC Page 4 of 9

Function Buttons Clear Data Print Click Clear Data to manually clear the data without printing a report. Click Print to manually print a report and clear data for the next batch. Data Display Sample Avg Std Dev Max Min Diff The current sample number and value received from the measurement gauge are displayed. The average of all samples in the batch is displayed. The standard deviation of all samples in the batch is displayed. The maximum value of all samples in the batch is displayed. The minimum value of all samples in the batch is displayed. The difference between the maximum and the minimum is displayed. BadgerWare, LLC Page 5 of 9

Section 3 System Setup Click System Setup on the Menu to display the System Setup window. Timeout Specify the timeout period (in seconds). After a measurement value is received, another must be received before the timeout period expires or a batch report will be automatically printed and the data will be cleared. Note: A timeout period of 0 seconds will disable automatic printing. Output Type Select the output type for the reports. The choices are Printed Report, Report File, or Both. BadgerWare, LLC Page 6 of 9

Section 4 Configure COM Port Click COM Port on the Menu to display the Configure COM Port window. COM Port settings are configurable for communication with the measurement gauge. These settings must match those of the measurement gauge. COM Port Baud Rate Parity Data Bits Stop Bits Specifies the COM Port of the PC to which the measurement gauge is connected. Specifies the baud rate of the serial communication between the PC and the measurement gauge (1200, 2400, 4800, 9600, or 19200). Specifies the parity for the serial communication between the PC and the measurement gauge (none, odd, or even). Specifies the number of data bits for the serial communication between the PC and the measurement gauge (7 or 8). Specifies the number of stop bits for the serial communication between the PC and the measurement gauge (1 or 2). OK Cancel Click OK to accept changes. Click Cancel to discard changes. BadgerWare, LLC Page 7 of 9

Section 5 Security The VersaPrint software has three levels of security. The security level is specified on the System Setup window. Security status is saved to disk and retrieved each time VersaPrint is run. Enabling Security When Security is disabled, click Security on the Menu to display the Lock prompt. To enable Security, enter a password (up to 8 alphanumeric characters), verify the password, and click OK. To exit from the Lock prompt without enabling Security, click Cancel. Disabling Security When Security is enabled, click Security on the Menu to display the Unlock prompt. To disable Security, enter the same password used to enable Security and click OK. To exit from the Lock prompt without disabling Security, click Cancel. BadgerWare, LLC Page 8 of 9

Section 6 Batch Reports When Output Type is set to Printed Reports or Both, printed batch reports will be generated automatically if the timeout period expires or manually upon clicking Print. Batch reports will be of the following format: When Output Type is set to Report File or Both, a text file containing the batch report data will be saved to the specified folder in addition to a hardcopy report being printed. The text files will be named per the date and time (e.g. 14Nov11 15_22_33.txt) and will be of the following format: Nov 13, 2011 19:18:58 Sample 1: 0.0979 Sample 2: 0.1016 Sample 3: 0.0985 Sample 4: 0.0990 Sample 5: 0.1008 Sample 6: 0.1000 Sample 7: 0.1008 Sample 8: 0.1012 Batch Report Average: 0.1000 Std Dev: 0.0014 Maximum: 0.1016 Minimum: 0.0979 Difference: 0.0037 BadgerWare, LLC Page 9 of 9