Brochure AP MCC C 07A Ceiling Concealed Split System C Series
features: Microprocessor Controlled ith the microprocessor controlling the operation, the MCC model can offer comfortable room conditions according to the needs of the user. In addition, its control algorithms provide protection to components of the air conditioning unit against any faults. Auto Random Restart During occasion of power failure, the unit will automatically restart according to the last setting condition when power resumed. Option is provided to cancel this feature. Flexibility In System Design The unit offers fan motor that can operate up to 4 speeds(models M5CC028C & above only), thus provide choices of external static pressure for designing ducting system. In addition, a range of MCCC model with optional specification of low external static pressure is also provided to cater for short duct application. Please refer to the technical specification of MCC model. Self Diagnosis Features' The microprocessor provides the possibility to detect and to diagnose any faults that occur in the system. Faults are displayed as error code in the wired controller. This will ease the troubleshooting process Double Protection Drainage System Primary Drain Pan Polysterene (Ps) ith Height Impact Polystyrene (Hips) Cover Secondary Drain Pan ith Insulation The primary drain pan is designed with high thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan built in to the standard unit offers extra protection against possible water leaking problems. Duct Accessories (Optional) A set duct accessories specifically designed to fit and to suit the MCCC model is being created. Thus offers a one stop solution to installing the unit. * Available for MCC 010025 C/CR only Flexible Round Duct (field supply) Discharge Adaptor Square Grille Assembly c/w Adaptor Secondary Drain Pan with Insulation Ceiling Concealed Unit Square Return Grille Assembly c/w Adaptor & Filter Primary Drain Pan MCC Return Assembly Bracket c/w Adaptor Flexible Round Duct (field supply)
NIM Able The MCC range of product is able to communicate with the versatile NIM networking control module and offers the opportunity of one centralized control for a system of multiple indoor units in a building. Choices Of ired And ireless Controller SLM 3 AC5300 ireless Controller (Optional) Netare III Controller (Optional) Standard units come with a simple and user friendly SLM 3. An optional specification of MCCC series is also available that comes with Netware III, which offers wide range of control features that includes 7 days and 24 hours timer settings, self diagnosis error code display and more. In addition, an innovative and compact wireless controller (credit card size), AC5300 provides wireless command to the SLM 3 & NETARE III. R410A Refrigerant 50%R32 50%R125 Ozone Depletion Potential = 0 Higher volumetric capacity and increased COP compared to R22 * Available for M5CC 010/015/020/025/028 C(CR) only Better Air Distribution The conditioned air can be effectively distributed to every corner of the room through the ducting and this ensures a more pleasant environment for comfortable living. Multiple rooms can be cooled together at the same time by using just one unit of fan coil.
CEILING CONCEALED MCCC SERIES R22 HEAT PUMP MODEL NOMINAL CAPACITY NOMINAL CAPACITY EER NOMINAL CAPACITY EER POER SOURCE COP ( STATIC) EXTERNAL STATIC PRESSURE ( STATIC, H/M/L) UNIT EXTERNAL STATIC PRESSURE (H/M/L) / / / MCC 010CR MLC 010CR 900 790 3.17 3.62 MCC 010C MLC 010C 900 3.17 142 / 300 123 / 260 104 / 220 127 / 270 118 / 250 99 / 210 49 / 39 / 29 (0.20 / 0.16 / 0.12) 540 / 21.3 700 / 27.6 250 / 9.8 32 / 70.5 MCC 015CR MLC 015CR 12300 3600 12000 3515 1222 1062 3.04 3.44 MCC 015C MLC 015C 12300 3600 1267 2.93 241 / 510 208 / 440 170 / 360 255 / 540 222 / 470 165 / 350 49 / 39 / 20 (0.20 / 0.16 / 0.08) 20 / 9.8 / 4.9 (0.08 / 0.04 / 0.02) 33 / 30 / 26 765 / 30.12 17 / 37.5 46 37 / 34 / 29 905 / 35.63 21 / 46.3 49 MLC 018CR 18000 5280 18500 5420 1910 1750 2.87 3.23 MLC 018C 18000 5280 1910 2.87 330 / 700 321 / 680 293 / 620 307 / 650 303 / 640 269 / 570 MCC 020CR MCC 020C MLC 020CR 19000 5570 19800 00 1895 1845 3.06 3.27 MLC 020C 19000 5570 1895 3.06 330 / 700 321 / 680 293 / 620 307 / 650 303 / 640 269 / 570 69 / 65 / 42 (0.28 / 0.26 / 0.17) 29 / 20 / 9.8 (0.12 / 0.08 / 0.04) 38 / 36 / 34 1065 / 41.93 22 / 48.5 38 / 36 / 34 1065 / 41.93 22 / 48.5 51 51 648 / 25.5 57 / 125.7 59 / 130.1 MCC 025CR MLC 025CR 23500 6890 24000 7030 2616 2536 2.63 2.77 MCC 025C MLC 025C 23500 6890 2616 2.63 345 / 730 340 / 720 274 / 0 363 / 770 340 / 720 274 / 0 41 / 31 / 18 (0.16 / 0.12 / 0.07) 25 / 15 / 5 (0.10 / 0.06 / 0.02) 40 / 39 / 36 1200 / 47.24 25 / 55.1 52 62 / 136.7 HEAT PUMP MODEL NOMINAL CAPACITY NOMINAL CAPACITY EER COP 60HZ EER COP NOMINAL CAPACITY EER 60HZ EER POER SOURCE SUPER SUPER ( STATIC) EXTERNAL STATIC PRESSURE (SH/H/M/L) EXTERNAL STATIC PRESSURE ( STATIC, SH/H/M/L) UNIT / / / / / / MLC 028CR 27000 7913 8206 3091 2638 2.64 3.23 MLC 028C 27000 7913 3091 2.64 MCC 028CR MLC 030CR 3090 <3070> 3060 <3040> 2.94 <2.86> 2.87 <2.99> 20 3082 3.41 2.85 MCC 028C MLC 030C 8206 2821 <2981> 3.01 <2.85> 3292 2.49 401 / 850 382 / 810 363 / 770 335 / 710 98 / 78 / 68 / 59 (0.39 / 0.31 / 0.28 / 0.24) 44 / 41 / 38 / 34 285 / 11.22 1007 / 39.65 600 / 23.62 38 / 83.8 54 68 / 149.9 95 / 209.4 MLC 028CR 8602 29000 8499 3153 2729 2.79 3.38 MCC 030CR MLC 030CR 3145 <3125> 3115 <3095> 3.00 <3.02> 3.03 <3.27> 2620 3490 3.36 2.52 MLC 035CR 35000 10257 36000 10550 3303 3303 3.38 3.48 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL AND CAPACITY ARE BASED ON THE CONDITIONS BE : a) 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BE THE CENTER OF THE UNIT. TESTED ITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET. 5) EER/ COP CALCULATION IS BASED ON THE EFFECTIVE POER INPUT AS PER ISO5151 MCC 038CR MLC 040CR 38000 11137 38500 11280 3766 <3736> 3476 <3436> 3.19 <3.21> 3.51 <3.56> 3130 3787 3.56 2.98 MCC 030C MCC 038C MLC 028C MLC 030C MLC 035C MLC 040C 29000 35000 35000 8206 8493 10257 10257 3153 2690 <2760> 3443 3473 <3443> 2.79 3.43<3.34> 3.23 3.20<3.23> 3720 4087 2.28 2.51 <380 415 / 3 / 50> 425 / 900 727 / 1540 392 / 830 694 / 1470 359 / 760 670 / 1420 335 / 710 637 / 1350 444 / 940 415 / 880 373 / 790 349 / 740 206 / 167 / 127 / 88 (0.83 / 0.67 / 0.51 / 0.35) 137 / 118 / 108 / 88 (0.55 / 0.47 / 0.43 / 0.35) 49 / 39 / 29 / 20 (0.20 / 0.16 / 0.12 / 0.08) 49 / 46 / 42 / 38 55 / 51 / 48 / 45 305 / 12.01 929 / 36.57 1302 / 51.26 638 / 25.12 39 / 86.0 41 / 90.4 54 68 / 149.9 95 / 209.4 95 / 209.4 100 / 220.5
CEILING CONCEALED MCCC SERIES R22 HEAT PUMP MODEL NOMINAL CAPACITY NOMINAL CAPACITY 50Hz 60Hz NOMINAL CAPACITY 60HZ EER COP EER COP EER EER POER SOURCE ( STATIC) MLC 035CR MLC 040CR 33500 40000 9818 11723 35000 40000 10257 11723 3265 3728 <3698> 3265 3238 <3208> / 3.30 3.41 <3.44> / 3.45 3.98 <4.02> 3100 3800 / 3.78 / 3.09 MCC 040C MLC 035C MLC 040C 33500 38500 9811 11276 3290 3420 <3390> / 3.27 3.61 <3.64> 4110 / 2.74 EXTERNAL STATIC PRESSURE (SH/H/M/L) EXTERNAL STATIC PRESSURE ( STATIC, SH/H/M/L) UNIT SUPER SUPER 95 / 209.4 100 / 220.5 MCC 040CR 519 / 1100 500 / 1060 467 / 990 425 / 900 562 / 1190 500 / 1060 472 / 1000 4 / 970 206 / 176 / 127 / 93 (0.83 / 0.71 / 0.51 / 0.37) MCC 050CR MLC 050CR 50000 14654 53000 15533 <5047> <4447> <3.11> <3.78> 4160 4623 3.52 3.36 MCC 050C MLC 050C 47000 13765 <4810> <3.08> 5233 2.63 <380 415 / 3 / 50> 750 / 1590 651 / 1380 604 / 1280 571 / 1210 713 / 1510 628 / 1330 618 / 1310 599 / 1270 176 / 157 / 137 / 108 (0.71 / 0.63 / 0.55 / 0.43) 49 / 39 / 29 / 20 (0.20 / 0.16 / 0.12 / 0.08) 78 / 59 / 39 / 20 (0.31 / 0.24 / 0.16 / 0.08) 51 / 49 / 45 / 41 1045 / 41.14 42 / 92.6 53 / 52 / 50 / 47 1299 / 51.14 54 / 119.1 105 / 231.49 MCC 060CR MLC 061CR 56000 16410 56000 16410 <6010> <4980> <2.91> <3.57> 5550 5937 2.96 2.76 MCC 060C MLC 061C 56000 16410 <6000> <2.92> 6837 2.40 779 / 1650 722 / 1530 675 / 1430 609 / 1290 802 / 1700 765 / 1620 717 / 1520 693 / 1470 176 / 157 / 137 / 98 (0.71 / 0.63 / 0.55 / 0.39) 69 / 49 / 29 / 20 (0.28 / 0.20 / 0.12 / 0.08) 55 / 53 / 50 / 47 1499 / 59.02 62 / 136.7 61 460 / 18.10 108 / 238.10 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL AND CAPACITY ARE BASED ON THE CONDITIONS BE : a) 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BE THE CENTER OF THE UNIT. TESTED ITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET. 5) EER/ COP CALCULATION IS BASED ON THE EFFECTIVE POER INPUT AS PER ISO5151
CEILING CONCEALED M5CCC SERIES R410A HEATPUMP MODEL POER SOURCE NOMINAL CAPACITY NOMINAL CAPACITY 50 Hz EER COP NOMINAL CAPACITY 50 Hz EER EXTERNAL STATIC PRESSURE (H/M/L) UNIT / / / M5CC 010CR M5LC 010CR 961 813 2.96 3.52 M5CC 010C M5LC 010C 961 2.96 142 / 300 123 / 260 104 / 220 49 / 39 / 29 (0.20 / 0.16 / 0.12) 33 / 30 / 26 765 / 30.12 17 / 37.5 46 540 / 21.3 700 / 27.6 250 / 9.8 32 / 70.5 M5CC 015CR M5LC 015CR 12500 3660 12000 3520 1297 1147 2.91 3.18 M5CC 015C M5LC 015C 12500 3660 1297 2.91 241 / 510 208 / 440 170 / 360 49 / 39 / 20 (0.20 / 0.16 / 0.08) 37 / 34 / 29 905 / 35.63 21 / 46.3 49 M5CC 020CR M5LC 020CR 18000 <18000> 5280 <5280> 18500 <18500> 5420 <5420> 1757 <1791> 1597 <1561> 3.13 <3.07> 3.55 <3.64> M5CC 020C M5LC 020C 18000 <18000> 5280 <5280> 1757 <1791> 3.13 <3.07> M5CC 025CR M5LC 025CR 21000 <22860> 6155 <6700> 22000 <23200> 6450 <6800> 2003 <2274> 1953 <2167> 3.15 <3.02> 3.39 <3.22> M5CC 025C M5LC 025C 21000 <22860> 6155 <6700> 2003 <2274> 3.15 <3.02> 220240/1/50 <380415/3/50> 316 / 670 302 / 640 278 / 590 69 / 65 / 42 (0.28 / 0.26 / 0.17) 38 / 36 / 34 1065 / 41.93 22 / 48.5 52 648 / 25.5 59 / 130.1 382 / 810 359 / 760 288 / 610 41 / 31 / 18 (0.16 / 0.12 / 0.07) 40 / 39 / 36 1200 / 47.24 25 / 55.1 52 62 / 136.7 HEATPUMP MODEL 50 Hz EER COP NOMINAL CAPACITY NOMINAL CAPACITY NOMINAL CAPACITY 50 Hz EER POER SOURCE SUPER EXTERNAL STATIC PRESSURE (SH/H/M/L) (SH/H/M/L) UNIT / / / M5CC 028CR M5LC 028CR 26000 <27000> 7620 <7910> 26000 <> 7620 <8210> 2892 <2876> 2429 <2528> 2.73 <2.85> 3.27 <3.38> M5CC 028C M5LC 028C 26000 <27000> 7620 <7910> 2892 <2876> 2.73 <2.85> 401 / 850 382 / 810 363 / 770 335 / 710 98 / 78 / 68 / 59 (0.39 / 0.31 / 0.28 / 0.24) 44 / 41 / 38 / 34 285 / 11.22 1007 / 39.65 600 / 23.62 38 / 84 54 68 / 149.9 M5CC 038CR M5LC 035CR M5LC 040CR <32000> <39000> <9380> <11430> <36000> <42000> <10550> <12310> <3337> <4173> <3137> <4203> <3.03> <2.88> <3.64> <3.08> M5CC 038C M5LC 035C <32000> <9380> <3337> <3.03> M5LC 040C <39000> <11430> <4173> <2.88> 220240/1/50 <380415/3/50> 604 / 1280 547 / 1160 496 / 1050 434 / 920 118 / 96 / 78 / 61 (0.47 / 0.39 / 0.31 / 0.24) 52 / 49 / 48 / 45 305 / 12.0 1302 / 51.3 638 / 25.1 41 / 90 95 / 209.4 100 / 220.5 M5CC 050CR M5LC 050CR <48000> <14070> <49000> <14360> <5115> <4535> <2.94> <3.42> M5CC 050C M5LC 050C <48000> <14070> <5115> <2.94> 675 / 1430 623 / 1320 0 / 1230 533 / 1130 147 / 126 / 109 / 92 (0.59 / 0.50 / 0.44 / 0.37) 54 / 53 / 52 / 51 378 / 14.9 1299 / 51.1 541 / 21.3 54 / 119 68 105 / 231.5 M5CC 060CR M5LC 061CR <54500> <15970> <57000> <16710> <5765> <5685> <2.98> <3.16> M5CC 060C M5LC 061C <54500> <15970> <5765> <2.98> 812 / 1720 732 / 1550 632 / 1340 552 / 1170 147 / 120 / 90 / 69 (0.59 / 0.48 / 0.36 / 0.28) 54 / 52 / 50 / 46 378 / 14.9 1499 / 59.0 541 / 21.3 62 / 137 65 460 / 18.1 108 / 238.1 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL AND CAPACITY ARE BASED ON THE CONDITIONS BE : a) 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BE THE CENTER OF THE UNIT. TESTED ITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET. 5) EER/COP CALCULATION IS BASED ON EFFECTIVE POER INPUT AS PER ISO 5151. 2007 McQuay International +1 (800) 4321342 www.mcquay.com A Global Leader in System Solutions for Air Conditioning, Heating, Ventilating and Refrigeration.