Datasheet SRB301ST 24V (V.2)

Similar documents
Datasheet - SRB 301LC/B-24V

Datasheet - SRB 402EM-24V

Datasheet - SLB 200-C04-1R

Datasheet - AZM300Z-ST-1P2P-A

Datasheet - MZM 100 B ST-1P2PW2REM-A

Datasheet - AZM 200SK-T-1P2PW

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Datasheet AZM 161 Z ST1 AS RA

Datasheet - RSS 36-D-R-ST

Datasheet - CSS 11-30S-D-M-ST

Datasheet - BNS ZG

Datasheet - BNS ZG-ST

Datasheet - AZM 200 BZ ST-T-AS P

Datasheet - AZ 16-02ZVRK-ST

Datasheet - AZ 15 ZVRK

Datasheet - AZ 16-03ZVRK

Datasheet - ZR Z

Datasheet - ZS Z

Datasheet - ZR Z

Datasheet - AZ 15 ZVRK

Datasheet - AZ 15 ZVK

Datasheet - AZ 15 ZVRK

Datasheet - AZ 16-02ZVK

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

Datasheet - AZ 16ZVRK

Datasheet - AZ 15 ZVRK

Safety controlling systems PROTECT series / Version 02

Operating instructions Safety-monitoring module SRB301STV.2 /CCV.2 /PCV.2 SRB301STV.3 /CCV.3 /PCV About this document.

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301ST V.2. 1 About this document

Operating instructions Safety-monitoring module SRB 301LC/B SRB 301LC/B-R. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301LC / LCI / LCI/7. 1. About this document. Content

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Operating instructions Safety-monitoring module SSW 301HV. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 324ST V About this document. Content

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

E-STOP relays, safety gate monitors

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Operating instructions Safety-monitoring module SRB 301ST-230V. 1 About this document

Operating instructions Fail-safe standstill monitor FWS About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Operating instructions Safety-monitoring modules SRB201ZH -24VDC. 1. About this document. Content

Operating instructions Safety-monitoring module SRB-E-204ST / SRB-E-204PE. Content. 1. About this document

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Operating instructions Safety-monitoring module SRB 301HC/R-24V / -230V. 1 About this document

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Operating instructions Safety-monitoring module SRB 324ST V.3. 1 About this document

SAFETY PRESSURE MATS GENERAL PRODUCT FEATURES

Operating instructions Safety-monitoring module SRB 207AN. 1. About this document. Content

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Safe timer relay/contact expansion modules

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

PNOZ s1. Safety relays. Operating Manual EN-07

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Contact expander modules

Two-hand control unit

ITEM ESM-BA301

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Two-hand control unit

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Safety relays PNOZsigma

E-STOP relays, safety gate monitors

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

MSR178DP. Description. Features. Specifications

E-STOP relays, safety gate monitors

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

E-STOP relays, safety gate monitors

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

PNOZ s9. Safety relays. Operating Manual EN-08

Transcription:

26.10.2016 05:03:31h Datasheet SRB301ST 24V (V.2) Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB301ST Suitable for signal processing of potential free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains Fit for signal evaluation of outputs of safety magnetic switches 3 safety contacts, STOP 0 1 Signalling output (Minor differences between the printed image and the original product may exist!) Ordering details Product type description SRB301ST 24V (V.2) Article number 103006151 EAN code 4030661476179 ecl@ss 27 37 19 01 Approval Approval BG USA/CAN Classification Standards EN ISO 13849 1, IEC 61508, EN 60947 5 1 PL up e (STOP 0) Control category up 4 (STOP 0) DC 99% (STOP 0) CCF > 65 points PFH value 2,0 x 10 8/h (STOP 0) SIL up 3 ( STOP 0) Mission time 20 Years notice The PFH value is applicable for the combinations listed in the table for contact load (K) (current through enabling paths) and switching cycle number (n op/y). In case of 365 operating days per year and a 24 hour operation, this results in the specified switching cycle times (t cycle) for the http://www.schmersal.net/datenblatt?lang=en&produkt=6i37333318zh9d7zeeq69285di5pxl 1/7

relay contacts. Diverging applications on request. Global Properties Product name Standards SRB301ST IEC/EN 60204 1, EN 60947 5 1, EN ISO 13849 1, IEC 61508, EN 81 1/ 2 Compliance with the Directives (Y/N) Climatic stress EN 60068 2 78 Mounting snaps onto standard DIN rail to EN 60715 Terminal designations IEC/EN 60947 1 Materials Material of the housings Plastic, glass fibre reinforced thermoplastic, ventilated Material of the contacts, self cleaning, positive action Weight 240 g Start conditions Automatic or Start button ( Optional monitored) Start input (Y/N) Feedback circuit (Y/N) Start up test (Y/N) No Automatic reset function (Y/N) Reset with edge detection (Y/N) Pull in delay ON delay with automatic start 100 ms ON delay with reset button 15 ms Drop out delay Drop out delay in case of power failure 100 ms Drop out delay in case of emergency stop 25 ms / 32 ms Mechanical data Connection type Screw connection, plug in Cable section Min. Cable section 0,25 mm² Max. Cable section 2.5 mm² Pre wired cable rigid or flexible Tightening torque for the terminals 0,6 Nm Detachable terminals (Y/N) Mechanical life 10.000.000 operations Electrical lifetime Derating curve available on request restistance to shock 30 g / 11 ms Resistance to vibration To EN 60068 2 6 10...55 Hz, Amplitude 0,35 mm Ambient conditions Ambient temperature Min. environmental temperature 25 C Max. environmental temperature +60 C Storage and transport temperature Min. Storage and transport temperature 40 C Max. Storage and transport temperature +85 C Protection class Protection class Enclosure IP40 Protection class Terminals IP20 Protection class Clearance IP54 Air clearances and creepage distances To IEC/EN 60664 1 Rated impulse withstand voltage Uimp 4 kv http://www.schmersal.net/datenblatt?lang=en&produkt=6i37333318zh9d7zeeq69285di5pxl 2/7

Overvoltage category II To VDE 0110 Degree of pollution 2 To VDE 0110 Electromagnetic compatibility (EMC) EMC rating conforming to EMC Directive Electrical data Rated DC voltage for controls Min. rated DC voltage for controls 20.4 V Max. rated DC voltage for controls 28.8 V Rated AC voltage for controls, 50 Hz Min. rated AC voltage for controls, 50 Hz 20.4 V Max. rated AC voltage for controls, 50 Hz 26.4 V Rated AC voltage for controls, 60 Hz Min. rated AC voltage for controls, 60 Hz 20.4 V Max. rated AC voltage for controls, 60 Hz 26.4 V Contact resistance Power consumption Type of actuation Switch frequency max. 100 mω 2 W; 4.9 VA AC/DC max. 5 Hz Rated operating voltage Ue 24 VDC 15% / +20%, residual ripple max. 10% 24 VAC 15% / +10% Operating current Ie Frequency range Electronic protection (Y/N) Fuse rating for the operating voltage Bridging in case of voltage drops 0,09 A 50 / 60 Hz Internal electronic trip, tripping current F1: > 0,5 A; tripping current (S11, S21): > 50 ma Reset after disconnection of supply voltage 80 ms Inputs Monitored inputs Short circuit recognition (Y/N) Wire breakage detection (Y/N) Earth connection detection (Y/N) Number of shutters Number of openers Cable length Conduction resistance 2 piece 1500 m with 1.5 mm²; 2500 m with 2.5 mm² max. 40 Ω Outputs Stop category 0 Number of safety contacts Number of auxiliary contacts Number of signalling outputs Switching capacity http://www.schmersal.net/datenblatt?lang=en&produkt=6i37333318zh9d7zeeq69285di5pxl 3/7 3 piece 1 piece Switching capacity of the safety contacts max. 250 VAC, 8 A ohmic (inductive in case of appropriate protective wiring) min. 10 V, 10 ma Switching capacity of the auxiliary contacts 24 VDC, 2 A Fuse rating Protection of the safety contacts 8 A slow blow Fuse rating for the auxiliary contacts 2 A slow blow Utilisation category To EN 60947 5 1 AC 15: 230 V / 6 A DC 13: 24 V / 6 A Note on the utilisation category Residual current at ambient temperature up to: 45 C = 24 A; 55 C = 18 A; 60 C = 12 A

Number of undelayed semi conductor outputs with signaling function Number of undelayed outputs with signaling function (with contact) Number of delayed semi conductor outputs with signaling function. 1 piece Number of delayed outputs with signalling function (with contact). Number of secure undelayed semi conductor outputs with signaling function Number of secure, undelayed outputs with signaling function, with contact. Number of secure, delayed semi conductor outputs with signaling function Number of secure, delayed outputs with signaling function (with contact). 3 piece LED switching conditions display LED switching conditions display (Y/N) Number of LED s 5 piece LED switching conditions display The integrated LEDs indicate the following operating states. Position relay K1 Position relay K2 Supply voltage Internal operating voltage Ui QS: cross wire short detection status (LED on when cross wire short detection active) Miscellaneous data Applications Emergency Stop button Guard system Pull wire emergency stop switches Safety sensor Safety light curtain Dimensions Dimensions Width 22.5 mm Height 120 mm Depth 121 mm notice Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. notice Wiring example Input level: The example shows a 2 channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R) and feedback circuit (H2). The control recognises cross short, cable break and earth leakages in the monitoring circuit. F1 = hybrid fuse Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive guided contacts. Switch setting: The cross wire short detection function (factory default) is programmed by means of the switch located underneath the front cover of the module: Pposition nqs (top): http://www.schmersal.net/datenblatt?lang=en&produkt=6i37333318zh9d7zeeq69285di5pxl 4/7

no cross wire short protection, suitable for 1 channel applications and applications with outputs with potential in the control circuits. Position QS (bottom): cross wire short protection, suitable for 2 channel applications without outputs with potential in the control circuits. For 1 channel control, connect NC contact to S11/S12 and bridge S12/S22 (QS switch = nqs) Connect potential p type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential. (QSswitch = nqs) Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals S12/X3. If the feedback circuit is not required, establish a bridge The wiring diagram is shown with guard doors closed and in de energised condition. Documents Operating instructions and Declaration of conformity (it) 389 kb, 28.07.2015 Code: mrl_srb_301st_v2v3_it Operating instructions and Declaration of conformity (es) 386 kb, 31.07.2015 Code: mrl_srb_301st_v2v3_es Operating instructions and Declaration of conformity (en) 456 kb, 27.09.2016 Code: mrl_srb_301st_v2v3_en Operating instructions and Declaration of conformity (cs) 407 kb, 06.11.2015 Code: mrl_srb_301st_v2v3_cs Operating instructions and Declaration of conformity (pl) 409 kb, 28.07.2015 Code: mrl_srb_301st_v2v3_pl Operating instructions and Declaration of conformity (pt) 392 kb, 11.09.2015 Code: mrl_srb_301st_v2v3_pt Operating instructions and Declaration of conformity (jp) 490 kb, 05.12.2014 Code: mrl_srb_301st_v2v3_jp Operating instructions and Declaration of conformity (fr) 384 kb, 09.04.2013 Code: mrl_srb_301st_v2v3_fr Operating instructions and Declaration of conformity (cn) 488 kb, 27.05.2015 Code: mrl_srb_301st_v2v3_cn Operating instructions and Declaration of conformity (de) 448 kb, 27.09.2016 Code: mrl_srb_301st_v2v3_de Operating instructions and Declaration of conformity (nl) 384 kb, 20.06.2013 Code: mrl_srb_301st_v2v3_nl Operating instructions and Declaration of conformity (sv) 376 kb, 07.08.2015 Code: mrl_srb_301st_v2v3_sv Wiring example (99) 129 kb, 15.10.2013 Code: ksrb3l315 Wiring example (99) 128 kb, 15.10.2013 Code: ksrb3l314 BG test certificate (de, en) 464 kb, 27.09.2016 Code: z_301p02 TÜV certification (de, en) 617 kb, 07.03.2013 Code: z_srbp03 http://www.schmersal.net/datenblatt?lang=en&produkt=6i37333318zh9d7zeeq69285di5pxl 5/7

TÜV certification (de) 1 MB, 07.03.2013 Code: z_s30p01 CCC certification (en) 104 kb, 20.11.2015 Code: q_srbp03 CCC certification (cn) 95 kb, 20.11.2015 Code: q_srbp04 EAC certification (ru) 833 kb, 05.10.2015 Code: q_6042p17_ru Images Wiring example Wiring example http://www.schmersal.net/datenblatt?lang=en&produkt=6i37333318zh9d7zeeq69285di5pxl 6/7

Internal wiring diagram K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D 42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 26.10.2016 05:03:31h Kasbase 3.2.5.F.64I http://www.schmersal.net/datenblatt?lang=en&produkt=6i37333318zh9d7zeeq69285di5pxl 7/7