Manual Motor Protectors

Similar documents
29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Mini Contactors & Overloads

WEG Contactors - CWM and CWME Series

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

1492-SP Supplementary Protectors

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

CS8 Industrial Control Relays

TeSys IEC Contactors and Overload Relays

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Circuit Breakers Type CTI 25M, CTI 45MB

Micro Contactor MA Series

Protection Equipment

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Motor protection circuit breakers

Motor protection relays

3 Pole Contactors with AC operating coils

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

MOTOR & CIRCUIT PROTECTION

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Disconnect Switches. Safe Switching and Disconnecting

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

UL 489 DIN Rail Miniature Circuit Breakers

Allen-Bradley 700-K40E-DJ

TeSys contactors From 115 to 2750 A

UL 489 DIN Rail Miniature Circuit Breakers

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Section 4 Ground-Fault Protection Devices

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Electronic timer CT-ERS.21

CS7 Industrial Control Relays

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

Electronic timer CT-ARS.11

Allen-Bradley 1492-RCDA4A40

MOTOR PROTECTION CIRCUIT BREAKERS

60103 Circuit Breaker

Miniature Circuit Breakers and Supplementary Protectors. Contents

RM35TF V AC

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Selection Guide. Control Circuit and Load Protection

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Bulletin 817 Thermistor Protection Relay

Control Circuit and Load Protection Products

Supplementary Circuit Protectors Type GSB63

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Allen-Bradley Bulletin 100 Contactors

Electronic timer CT-ERD.12

Selection Guide. Control Circuit and Load Protection

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

K-Line Mini - Contactors, Overload Relays and Accessories

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Complete UL/CSA Disconnect Switch Kits

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Electronic timer CT-AHD.22

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Contact protection relay

Jtec 10kA Miniature Circuit Breaker

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Miniature Circuit Breakers for Railway Applications

Overloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D

Load Feeders and Motor Starters for Use in the Control Cabinet

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

78 Series Electromechanical Relay Selection Guide

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

IEC Power Control Overload Relays

Motor protection circuit breakers

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

CS7 Industrial Control Relays

E-STOP relays, safety gate monitors

Transcription:

94 www.factorymation.com/motorcontrols MOTOR CONTROLS Manual Motor Protectors 30 IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100kA (with optional current limiter) Din rail mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal overload protection Trip test feature Phase loss protection Complies with IEC 60947-1 and IEC 60947-4-1, UL508 Listed (Manual motor controller) UL508 Listed (Combination motor controller starter) CSA C.22.2/14 1 year warranty 35 1 YR 1 UP TO 10HP YR 1 UP TO 2 YR WARRANTY WARRANTY WARRANTY 114 UP TO 60HP E468295 UL HP Ratings Thermal Short Circuit Current Part Number Price Single Phase Three Phase Adjustable Rating (SCCR) 115V 230V 200V 230V 460V 575V Range (A) 480V 600V 16 Amp Frame, Pushbutton Operator IMM16-P16A 30 - - - - - - 0.10 to 0.16 50kA 10kA IMM16-P25A 30 - - - - - - 0.16 to 0.25 50kA 10kA IMM16-P40A 30 - - - - - - 0.25 to 0.40 50kA 10kA IMM16-P63A 30 - - - - - - 0.40 to 0.63 50kA 10kA IMM16-1P0A 30 - - - - - 1/2 0.63 to 1.0 50kA 10kA IMM16-1P6A 30-1/10 - - 3/4 3/4 1.0 to 1.6 50kA 10kA IMM16-2P5A 30-1/6 1/2 1/2 1 1-1/2 1.6 to 2.5 50kA 10kA IMM16-4P0A 30 1/8 1/3 3/4 3/4 2 3 2.5 to 4.0 50kA 10kA IMM16-6P3A 30 1/4 1/2 1 1-1/2 3 5 4.0 to 6.3 50kA 10kA IMM16-010A 32 1/2 1-1/2 2 3 5 7-1/2 6.3 to 10 50kA 5kA IMM16-016A 32 1 2 3 5 10 10 10 to 16 30kA 5kA 32 Amp Frame, Rotary Operator IMM32-P16A 35 - - - - - - 0.10 to 0.16 50kA 25kA IMM32-P25A 37 - - - - - - 0.16 to 0.25 50kA 25kA IMM32-P40A 37 - - - - - - 0.25 to 0.40 50kA 25kA IMM32-P63A 37 - - - - - 1/4 0.40 to 0.63 50kA 25kA IMM32-1P0A 37 - - - - 1/2 1/2 0.63 to 1.0 50kA 25kA IMM32-1P6A 38-1/10 1/4 1/3 3/4 1 1.0 to 1.6 50kA 25kA IMM32-2P5A 38-1/6 1/2 1/2 1-1/2 1-1/2 1.6 to 2.5 50kA 25kA IMM32-4P0A 40 1/8 1/3 3/4 1 2 3 2.5 to 4.0 50kA 25kA IMM32-6P3A 40 1/4 3/4 1-1/2 1-1/2 5 5 4.0 to 6.3 50kA 25kA IMM32-010A 40 1/2 1-1/2 3 3 7-1/2 10 6.3 to 10 50kA 25kA IMM32-016A 40 1 3 5 5 10 15 10 to 16 50kA 25kA IMM32-020A 45 1-1/2 3 5 7-1/2 15 20 16 to 20 50kA 25kA IMM32-025A 48 2 3 7-1/2 7-1/2 15 20 20 to 25 50kA 25kA IMM32-032A 48-5 10 10 20 25 25 to 32 42kA 25kA 65 Amp Frame, Rotary Operator IMM65-040A 114 3 7 1/2-15 25 40 32 to 40 35kA 10kA IMM65-050A 114-10 15 15 30 40 40 to 50 35kA 10kA IMM65-065A 114 5 10 20 20 50 60 50 to 65 35kA 10kA To Order Call 1.800.972.0436 or Visit factorymation.com

Manual Motor Protectors (cont d) 95 IMA-TDH Through-the-door Handle UL Type 1/IP55 & UL Type 4X/IP65 Padlockable & Defeatable Rotary Handle Adjustable shafts Shows IMM position I (ON) or O (OFF) Available in Gray/Black or Red/Yellow Shown attached to Manual Motor Starter (sold separately) TYPE 1 / IP55 & TYPE 4X / IP65 PROTECTION IMA-TDH E468295 Part Number Price Handle Color IMA-TDH32-130-B1 18 Gray/Black IMA-TDH32-130-Y1 18 Red/Yellow IMA-TDH32-130-B4X 24 Gray/Black IMA-TDH32-130-Y4X 24 Red/Yellow IMA-TDH32-330-B1 19 Gray/Black IMA-TDH32-330-Y1 19 Red/Yellow IMA-TDH32-330-B4X 26 Gray/Black IMA-TDH32-330-Y4X 26 Red/Yellow IMA-TDH65-130-B4X 24 Gray/Black IMA-TDH65-130-Y4X 24 Red/Yellow IMA-TDH65-330-B4X 26 Gray/Black IMA-TDH65-330-Y4X 26 Red/Yellow Environmental Rating TYPE 1 / IP55 TYPE 4X / IP65 TYPE 1 / IP55 TYPE 4X / IP65 TYPE 4X / IP65 TYPE 4X / IP65 Shaft Length 5.12-6.10" (130-155mm) 12.99-13.98" (330-355mm) 5.12-6.10" (130-155mm) 12.99-13.98" (330-355mm) Applicable MMP IMM32 IMM32 IMM65 MOTOR CONTROLS IMM Bus Bars For parallel connection with IMM to contactor power terminals Simplifies wiring and reduces wiring space Multiple bus bars can be combined providing total current rating Total maximum current rating 63A @ 690VAC Link Adapters For electrical and mechanical direct connection between IMM and contactor Simplifies wiring and reduces wiring space Part Number Price Description IMA-LNKADP-16F-16MC 7 For IMM16 + IMCxxx-07S to IMCxxx-16S IMA-LNKADP-16F-25MC 7 For IMM16 + IMCxxx-25S IMA-LNKADP-32F-16MC 7 For IMM32 + IMCxxx-07S to IMCxxx-16S IMA-LNKADP-32F-25C 7 For IMM32 + ICxxx-09S to ICxxx-25S (IC contactor AC Coils Only) IMA-LNKADP-32F-40C 7 For IMM32 + ICxxx-32S to ICxxx-40S (IC contactor AC Coils Only) IMA-ENCL-16FY IMA-LNKADP-32F IMA-ENCL-32xx IMA-BBS32F-54-4 IMA-BBLST IMA-BBSHROUD Enclosed Disconnect Stations Conveniently house manual motor protector in sealed enclosure Two cable entry knockouts top and bottom Includes neutral and ground terminals Wide model available to accommodate side mounting accessories Part Number Price Description IMA-ENCL-16FY 16 Standard Disconnect Station with translucent membrane for IMM16, Red/Yellow, IP66 IMA-ENCL-32FB 18 Standard Disconnect Station for IMM32, Black, IP55 IMA-ENCL-32FY 18 Standard Disconnect Station for IMM32, Red/Yellow, IP55 IMA-ENCL-32FWB 20 Wide Disconnect Station for IMM32, Black, IP55 IMA-ENCL-32FWY 20 Wide Disconnect Station for IMM32, Red/Yellow, IP55 IMA-BBS32F Part Number Price Description IMA-BBS32F-45-2 8 45mm for 2 IMM16 or IMM32., 63A max. total IMA-BBS32F-45-3 9 45mm for 3 IMM16 or IMM32., 63A max. total IMA-BBS32F-45-4 10 45mm for 4 IMM16 or IMM32., 63A max. total IMA-BBS32F-45-5 12 45mm for 5 IMM16 or IMM32., 63A max. total IMA-BBS32F-54-2 8 54mm for 2 IMM16 or IMM32 w/ side mount aux., 63A max. total IMA-BBS32F-54-3 10 54mm for 3 IMM16 or IMM32 w/ side mount aux., 63A max. total IMA-BBS32F-54-4 11 54mm for 4 IMM16 or IMM32 w/ side mount aux., 63A max. total IMA-BBS32F-54-5 16 54mm for 5 IMM16 or IMM32 w/ side mount aux., 63A max. total IMA-BBS32F-63-2 8 54mm for 2 IMM16 or IMM32 with 2 side mounting aux contacts IMA-BBS32F-63-3 10 54mm for 3 IMM16 or IMM32 with 2 side mounting aux contacts IMA-BBS32F-63-4 11 54mm for 4 IMM16 or IMM32 with 2 side mounting aux contacts IMA-BBS32F-63-5 12 54mm for 5 IMM16 or IMM32 with 2 side mounting aux contacts IMA-BBSHROUD 3 Busbar Shroud for unused IMA-BBS32F & IMA-BBS54F terminals IMA-BBLST 9 Accessories Part Number Price Description Auxiliary Contacts IMA-AUX-F11 8 Front mount, 1 N.O./1 N.C., 250V max IMA-AUX-S02 10 Left side mount, 2 N.C., 600V max IMA-AUX-S11 10 Left side mount, 1 N.O./1 N.C., 600V max IMA-AUX-S20 10 Left side mount, 2 N.O., 600V max Alarm & Trip Signaling Switch IMA-ALARM-S02 12 Left side mount, 1 N.O./1 N.C. for short-circuit signaling and 1 N.O./1 N.C. for overload signaling Shunt Release IMA-SHR-AC24 17 Right side mount, 20-24V, 50/60Hz IMA-SHR-AC127 17 Right side mount, 110V-127V, 50/60Hz IMA-SHR-AC240 17 Right side mount, 200-240V, 50/60Hz Undervoltage Release IMA-UVR-AC24 17 Right side mount, 24V, 50Hz/60Hz IMA-UVR-AC120 17 Right side mount, 110V-120V, 50/60Hz IMA-UVR-AC127 17 Right side mount, 110-115/127V, 50/60Hz IMA-UVR-AC208 17 Right side mount, 208V, 60Hz IMA-UVR-AC240 17 Right side mount, 240V, 60Hz IMA-UVR-AC480 17 Right side mount, 2 N.O. Contacts, 400-415/480V, 50/60Hz Current Limiter IMA-CURLIM-32F 31 Provides enhanced short-circuit interrupt rating: 100kA@480V for Mounting Adapters IMA-MBDOL-32F 13 For DOL Starters, 45mm, use w/ IMM32 + IMCxxx-07S to IMCxxx- 25S or ICxxx-09S to ICxxx-25S IMA-MBREV-32F 17 For Reversing Starters, 90mm, use w/ IMM32 + (2) IMCxxx-07S to -25S or (2) ICxxx-09S to -25S IMA-MBYDEL-32F 26 For Star-Delta Motor Starters, 90mm, use w/ IMM32 + (2) IMCxxx- 07S to -25S or (2) ICxxx-09S to -25S IMA-MNTTAB 1 Mounting tabs for (1) IMM16, IMM32 & IMM65 direct mount to any surface using screws, 2pc/pkg Scale Protection Cover IMA-SDPC 3 For IMM16, IMM32 & IMM65 adjustment dial Incoming Power Terminals IMA-TYPEE-32F 13 For IMM32 IMA-TYPEE-65F 25 For IMM65 Incoming Power Terminal for Bus Bar System, 3-pole, IMM16 & IMM32 IMA-AUX-F11 IMA-ALARM-S02 IMA-CURLIM-32F www.factorymation.com/motorcontrols ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

96 Manual Motor Protectors (cont d) www.factorymation.com/motorcontrols MOTOR CONTROLS General Specifications General Specifications IMM16 IMM32 IMM65 Standards IMM Terminal Specifications 16 Amp Frame 32 Amp Frame 65 Amp Frame IEC 60947-1/60947-4-1, EN 60947-1 / EN 60947-4-1, UL508, CSA C.22.2/14 Rated Insulation (Ui) & Operating (Ue) Voltage [V] UL/CSA: 600V, IEC 60947-1: 690V Rated Impulse Voltage Acc. IEC60947-1 [kv] 6 Rated Operating Frequency [Hz] 50/60 Overvoltage Category Phase Failure Sensitivity Protection Overload Protection Characteristics (x lu) [A] 0.61 to 1 Magnetic Release (x lu) [A] 13 Overload Trip Class 10 Total Power Loss Pv At Rated Load Operating Temp [W] 6 6 (1.6A to 16A) / 8 (20A to 32A) 25 Utilization Category Lifespan Degree of Protection Resistance IEC 60947-2 (Motor Protector) IEC 60947-4-1 (Motor Starter) III Yes A AC-3 Mechanical: 100,000 ops., Electrical (le max.): 100,000 ops., Switching Rate (motor start) AC-3: 15 ops/hr IP20 Shock resistance: 15g/11ms, Vibration resistance: 10g/5-150Hz Screw Driver Philips #2 Philips #2 Allen #4 Terminal Capacity Environmental Conditions Solid - Stranded 1 or 2 conductors (18 to 12 AWG) (see IMM Terminal Specs) (see IMM Terminal Specs) Tightening Torque [lb-in] 11 to 16 lb-in (1.2 to 1.7 Nm) 18 to 22 lb-in (2.0 to 2.5 Nm) 55 lb-in (6.2 Nm) Ambient Temperature Storage: -58 to 176 F (-50 to 80 C), Operating: -4 to 140 F (-20 to 60 C) Climatic Proofing IEC 60068-2-3 / IEC 60068-2-30 Altitude (Up to 6,600ft) Altitude (Up to 6,600ft): Nominal values, Pollution degree: 3, Mounting position: Any Weight [lb] 0.7 0.7 1.42 Warranty Drawing (mm 2 ) (AWG) 10 Terminal Capacity IMM16/IMM32 1 or 2 x (1 to 2.5) 1 or 2 x (2.5 to 6) - - 1 or 2 x (14 to 10) 1 x (8) 1 or 2 x (1 to 2.5) 1 or 2 x (2.5 to 6) 1 or 2 x (14 to 10) 1 x (10) Terminal Capacity IMM65 Solid Ferrule Stranded Tightening Torque 1 Conductor on Lower Part Only 12 to 2 AWG 12 to 2 AWG A A 2 Conductors, 1 on Upper Part (A) and 1 on Lower Part (B) 16 to 2 AWG 16 to 2 AWG 12 to 2 AWG 16 to 2 AWG 16 to 2 AWG 12 to 2 AWG 8 to 2 AWG 14 to 2 AWG 14 to 2 AWG 8 to 2 AWG 55 lb-in (6.2 Nm) B B 1 year Trip Characteristics Extended Rotary Handle Dimensions in(mm) Manual Motor Protector Dimensions in(mm) B A A C D Average Curves Curve 1: 3 pole Curve 2: Bipolar with phase loss sensitivity Tripping time as function of the current at cold condition. For warm condition (after submitted to the rated operational current - Ie ), the tripping times reduce to approximately 25%. E-Handle Type A Min Max Inches (mm) MMS Type IMA-THD32 (TYPE 1) 5.9 8.3 (148.6 210.6) IMM32 IMA-TDH32 (TYPE 4X) 5.9 16.2 (148.6 410.6) IMM32 IMA-TDH65 (TYPE 4X) 7.6 10.1 (193.6 255.6) IMM65 in (mm) Dimensions A B C D IMM16 2.99 (76) 1.77 (45) 3.94 (100) 1.77 (45) IMM32 3.86 (98) 1.77 (45) 3.82 (97) 1.77 (45 IMM65 6.18 (157) 2.13 (54) 4.92 (125) 4.50 (114) The characteristics of the magnetic trip are based on the upper value of the setting range for IMM16, IMM32 & IMM65. To Order Call 1.800.972.0436 or Visit factorymation.com

Miniature Contactors & Overloads 97 1 YR WARRANTY 16A Frame 1/ 1 E468299 E108780 1/ to 1 Surface or DIN rail mountable UL508 Listed 50/60Hz AC and DC coil versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (16A Frame) IEC 60947 1 year warranty Optional Accessories Include: Additional auxiliary contact blocks Reverse mounting kits and interlocks Surge suppressors Direct mount to Manual Motor Starter (with optional adapter) Miniature Thermal Overload Relays IMCA-LCHBLK-16F 3-pole Contactors 3-pole Overloads 2-pole Overloads Price Current Range Applicable Contactor IMOL-16S-P40 IMOLS-16S-P40 14 0.28-0.40A IMOL-16S-P63 IMOLS-16S-P63 14 0.40-0.63A IMCxxx-07S IMOL-16S-P80 IMOLS-16S-P80 14 0.56-0.80A IMCxxx-09S IMOL-16S-1P2 IMOLS-16S-1P2 14 0.80-1.2A IMCxxx-12S IMOL-16S-1P8 IMOLS-16S-1P8 14 1.2-1.8A IMCxxx-16S IMOL-16S-2P8 IMOLS-16S-2P8 14 1.8-2.8A IMOL-16S-4P0 IMOLS-16S-4P0 14 2.8-4.0A IMOL-16S-6P3 IMOLS-16S-6P3 14 4.0-6.3A IMOL-16S-8P0 IMOLS-16S-8P0 14 5.6-8.0A IMCxxx-07S IMCxxx-09S IMOL-16S-010 IMOLS-16S-010 14 7-10A IMCxxx-12S IMOL-16S-012 IMOLS-16S-012 14 8-12.5A IMCxxx-16S IMOL-16S-015 IMOLS-16S-015 14 10-15A IMOL-16S-017 IMOLS-16S-017 14 11-17A IMOL-25S-023 IMOLS-25S-023 15 15-23A IMOL-25S-032 IMOLS-25S-032 15 23-32A IMCxxx-25S IMHA-SMB-25F 4 FMX Separate Mounting Bracket for IMOL-16S to IMOL-25S, screw or DIN-rail mountable IMOL-16S 11 7 25A Part Number UL HP Ratings (AC3 Motor Load) Optional Price Coil Voltage Single Phase Three Phase Overload 1 N.O. Aux Contact 1 N.C. Aux Contact 115V 230V 230V 460V 575V Relay 16A Frame Size IMC330-07S-10-AC24 IMC330-07S-01-AC24 11 24VAC (60Hz) IMC330-07S-10-AC120 IMC330-07S-01-AC120 11 110/120VAC (50/60Hz) IMC330-07S-10-AC240 IMC330-07S-01-AC240 11 208-240VAC (60Hz) 1/ 3/4HP 1-1/2HP IMC330-07S-10-AC480 IMC330-07S-01-AC480 11 400-415/480VAC (7.2A) (9A) (7A) (7A) (9A) IMOL-16S IMC330-07S-10-DC12-14 12VDC IMC330-07S-10-DC24 IMC330-07S-01-DC24 14 24VDC IMC330-09S-10-AC24-12 24VAC (60Hz) IMC330-09S-10-AC120-12 110/120VAC (50/60Hz) IMC330-09S-10-AC240-12 208-240VAC (60Hz) IMC330-09S-10-AC480-12 400-415/480VAC (50/60Hz) IMC330-09S-10-DC12-15 12VDC IMC330-09S-10-DC24-15 24VDC IMC330-12S-10-AC24-13 24VAC (60Hz) IMC330-12S-10-AC120-13 110/120VAC (50/60Hz) IMC330-12S-10-AC240-13 208-240VAC (60Hz) IMC330-12S-10-AC480-13 400-415/480VAC (50/60Hz) IMC330-12S-10-DC12-16 12VDC IMC330-12S-10-DC24-16 24VDC IMC330-16S-10-AC24 IMC330-16S-01-AC24 15 24VAC (60Hz) IMC330-16S-10-AC120 IMC330-16S-01-AC120 15 110/120VAC (50/60Hz) IMC330-16S-10-AC240 IMC330-16S-01-AC240 15 208-240VAC (60Hz) IMC330-16S-10-AC480 IMC330-16S-01-AC480 15 400-415/480VAC (50/60Hz) IMC330-16S-10-DC12-19 12VDC IMC330-16S-10-DC24 IMC330-16S-01-DC24 19 24VDC IMC330-16S-10-DC110-19 110VDC 25A Frame Size (Aux contacts sold separately) IMC330-25S-00-AC24 16 24VAC (60Hz) IMC330-25S-00-AC120 16 110/120VAC (50/60Hz) IMC330-25S-00-AC240 16 208-240VAC (60Hz) IMC330-25S-00-AC480 16 400-415/480VAC (50/60Hz) IMCA-AUX-316-F11 IMCA-MECINT-16F Mini Series Accessories 1/3 HP (9.8A) 1/ (12.8A) 1HP (16A) 1-1/2HP (22A) 1HP (12A) 2HP (16A) 2HP (17A) (25A) Part Number Price Description Auxiliary Contacts IMCA-AUX-316-F02 4 Front mount, 2 N.C., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F04 7 Front mount, 4 N.C., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F11 4 Front mount, 1 N.O./1 N.C., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F20 4 Front mount, 2 N.O., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F22 7 Front mount, 2 N.O./ 2 N.C., IMCxxx-07S to -16S Contactors IMCA-AUX-316-F40 7 Front mount, 4 N.O., IMCxxx-07S to -16S Contactors IMCA-AUX-325-F02 4 Front mount, 2 N.C., IMCxxx-25S Contactors IMCA-AUX-325-F11 4 Front mount, 1 N.O./1 N.C., IMCxxx-25S Contactors IMCA-AUX-325-F20 4 Front mount, 2 N.O., IMCxxx-25S Contactors Latch Block IMCA-LCHBLK-16F 3 For IMCxxx-07S to -16S Contactors Mechanical Interlock Block for Reversing Configuration IMCA-MECINT-16F 3 For IMCxxx-07S to -16S, front mount Reverse Wire Kit for Reversing Starters IMCA-REVKIT-16F 9 For IMCxxx-07S-01 to -16S-01 (N.C. aux. contactors only). Assemble IMOL-16S to -25S and IMM16 to 32 Surge Suppressors IMCA-DIODE-16F-DC600 3 Diode, Front Mount, 12-600VDC IMCA-RCSURG-25F-AC127 3 RC, Front Mount, 50-127VAC, 50/60Hz IMCA-RCSURG-25F-AC24 3 RC, Front Mount, 12-24VAC, 50/60Hz IMCA-RCSURG-25F-AC250 3 RC, Front Mount, 130-250VAC, 50/60Hz IMCA-RCSURG-25F-AC510 3 RC, Front Mount, 400-510VAC, 50/60Hz IMCA-VARSURG-25F-AD127 3 Varistor, Front Mount, 50-127VAC / 60-180VDC IMCA-VARSURG-25F-AD275 3 Varistor, Front Mount, 130-275VAC / 180-300VDC IMCA-VARSURG-25F-AD380 3 Varistor, Front Mount, 277-380VAC / 300-510VDC IMCA-VARSURG-25F-AD48 3 Varistor, Front Mount, 12-48VAC / 12-60VDC IMCA-VARSURG-25F-AD510 3 Varistor, Front Mount, 400-510VAC 50-60Hz Link Adapters IMA-LNKADP-16F-16MC 7 For IMM16 + IMCxxx-07S to IMCxxx-16S IMA-LNKADP-16F-25MC 7 For IMM16 + IMCxxx-25S (9A) (12A) (16A) 7-1/2HP (22A) (9A) IMA-LNKADP-32F-16MC 7 For IMM32 + IMCxxx-07S to IMCxxx-16S 7-1/2HP (11A) IMOL-16S 7-1/2HP 7-1/2HP IMOL-16S (12A) (17A) 10HP (16A) 1 (22A) 10HP (17A) 1 (27A) IMOL-16S IMOL-25S MOTOR CONTROLS www.factorymation.com/motorcontrols IMCA-REVKIT-16F IMCA-RCSURG-25F-AC127 IMA-LNKADP-16F-16MC ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

2.77(70) 98 Miniature Contactors & Overloads (cont d) www.factorymation.com/motorcontrols MOTOR CONTROLS 1 YR WARRANTY 1/ 10HP E468299 E108780 1/ to 10HP Surface or DIN rail mountable UL508 Listed 50/60Hz AC and DC coil versions available IEC 60947 1 year warranty Optional Accessories Include: Additional auxiliary contact blocks Reverse mounting kits and interlocks Surge suppressors Dimensions in(mm) 16A Frame IMCxxx-07S to -16S 3.4(86) 2.0(51) 13 7 16A 4-pole Contactors 2 NO Power Poles 2 NC Power Poles Price 4 NO Power Poles Price Coil Voltage 16A Frame Size IMC422-07S-00-AC24 13 IMC440-07S-00-AC24 13 24VAC (60Hz) IMC422-07S-00-AC120 13 IMC440-07S-00-AC120 13 110/120VAC (50/60Hz) IMC422-07S-00-AC240 13 IMC440-07S-00-AC240 13 208-240VAC (60Hz) IMC422-07S-00-AC480 13 IMC440-07S-00-AC480 13 400-415/480VAC IMC422-07S-00-DC12 16 IMC440-07S-00-DC12 16 12VDC IMC422-07S-00-DC24 16 IMC440-07S-00-DC24 16 24VDC IMC422-07S-00-DC110 16 IMC440-07S-00-DC110 16 110VDC IMC422-09S-00-AC24 14 IMC440-09S-00-AC24 14 24VAC (60Hz) IMC422-09S-00-AC120 14 IMC440-09S-00-AC120 14 110/120VAC (50/60Hz) IMC422-09S-00-AC240 14 IMC440-09S-00-AC240 14 208-240VAC (60Hz) IMC422-09S-00-AC480 14 IMC440-09S-00-AC480 14 400-415/480VAC IMC422-09S-00-DC12 17 IMC440-09S-00-DC12 17 12VDC IMC422-09S-00-DC24 17 IMC440-09S-00-DC24 17 24VDC IMC422-09S-00-DC110 17 IMC440-09S-00-DC110 17 110VDC IMC422-12S-00-AC24 14 IMC440-12S-00-AC24 14 24VAC (60Hz) IMC422-12S-00-AC120 14 IMC440-12S-00-AC120 14 110/120VAC (50/60Hz) IMC422-12S-00-AC240 14 IMC440-12S-00-AC240 14 208-240VAC (60Hz) IMC422-12S-00-AC480 14 IMC440-12S-00-AC480 14 400-415/480VAC IMC422-12S-00-DC12 19 IMC440-12S-00-DC12 19 12VDC IMC422-12S-00-DC24 19 IMC440-12S-00-DC24 19 24VDC IMC422-12S-00-DC110 19 IMC440-12S-00-DC110 19 110VDC IMC422-16S-00-AC24 19 IMC440-16S-00-AC24 19 24VAC (60Hz) IMC422-16S-00-AC120 19 IMC440-16S-00-AC120 19 110/120VAC (50/60Hz) IMC422-16S-00-AC240 19 IMC440-16S-00-AC240 19 208-240VAC (60Hz) IMC422-16S-00-AC480 19 IMC440-16S-00-AC480 19 400-415/480VAC IMC422-16S-00-DC12 21 IMC440-16S-00-DC12 21 12VDC IMC422-16S-00-DC24 21 IMC440-16S-00-DC24 21 24VDC IMC422-16S-00-DC110 21 IMC440-16S-00-DC110 21 110VDC Screw Mount 1.5(38) 3.3(84) 2.2 (56) 1.8(46) UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 230V 460V 575V 1/ (7.2A) 1/3 HP (9.8A) 1/ (12.8A) 1HP (16A) 3/4HP (9A) 1HP (12A) 2HP (16A) 2HP (17A) 1-1/2HP (7A) (9A) (12A) (16A) (7A) (9A) (9A) 7-1/2HP (11A) 7-1/2HP 7-1/2HP (12A) (17A) 10HP (16A) 10HP (17A) 2.3(58) IMC IMCA-AUX IMCA-LCHBLK-16F or IMCA-MECINT-16F 2.0(51) 2.3(58) 4.5(114) IMC IMOL IMOL-16S / -25S 1.77(45) IMCxxx-25S 3.3(84) 2.2(56) 2.3(58) IMC IMCA-AUX 3.26(83) To Order Call 1.800.972.0436 or Visit factorymation.com

Miniature Contactors & Overloads (cont d) 99 Miniature Contactor Specifications General Specifications IMCxxx-07S IMCxxx-09S IMCxxx-12S IMCxxx-16S IMCxxx-25S General Purpose Rating (A) 18 20 22 22 32 Rated Operational Voltage (V) 12 to 690 Rated Insulation Voltage (V) UL/CSA: 600, IEC/VDE 0660: 690 Rated Impulse Voltage IEC60947-1 (V) 4000 Rated Operating Frequency (Hz) 25 to 400 Degree of Protection Vibration Resistance (5 to 200Hz) Contactor Open (g) 2 Contactor Closed at Coil (g) 4 Mechanical Endurance (Million ops) 10 (AC Coil) / 12 (DC Coil) 3 (AC Coil) Electrical Endurance (Million ops) 1.4 1.3 1.2 1 0.6 Shock Resistance (1/2 Sin Wave = 11ms) Contactor Open (g) 6 6 6 6 6 Contactor Closed at Coil (g) 10 10 10 10 10 Terminal Capacity Main Contacts (AWG) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 10) Screw Driver Phillips #2 Phillips #2 Phillips #2 Phillips #2 Phillips #2 Tightening Torque (lb-in) 10 10 10 10 13 Environmental Conditions Ambient Temperature IP20 Storage: -67 to 176 F (-55 to 80 C), Operating: -4 to 140 F (-20 to 60 C) Climatic Withstand According to IEC 60680-2 Pollution Degree 3 Mounting 35mm DIN-rail Acc. DIN EN 50 022 Weight (lb) 0.42 0.42 0.42 0.42 0.42 Control Circuit Ratings (AC/DC COIL) Standard Voltages Coil Operating Limits Coil Consumption (Single coils) Power Factor Operating Time Miniature Overload Specifications General Specifications 12 to 660 (60Hz) Monofrequency Coils (NO LOAD) (V) 0.85 to 1.1 Pick-up (V) 0.40 to 0.76 (AC-60Hz) / 0.40 to 0.70 (DC) Drop-out (V) 0.25 to 0.65 (AC-60Hz) / 0.15 to 0.40 (DC) Sealed (VA) 2.5 to 3.5 2.5 to 3.5 2.5 to 3.5 2.5 to 3.5 10.8 to 13.2 Inrush (VA) 35 35 35 35 72 Closed Cos Φ 0.28 0.28 0.28 0.28 0.32 Opened Cos Φ 0.85 0.85 0.85 0.85 0.93 Coil Energization - N.O. (ms) 8 to 20 (AC-60Hz) / 10 to 20 (DC) 13 to 16 (AC-60Hz) Coil De-energization - N.O. (ms) 5 to 15 (AC-60Hz) / 2 to 8 (DC) 13.5 to 17 (AC-60Hz) Standards IEC 60947-1 / 60947-4-1, UL 508; CSA C.22.2/14; VDE 0660/102 Number of Poles 3 Rated Operation & Insulation Voltage [V] UL/CSA: 600, IEC 60947-4-1: 690 Rated Impulse Voltage, Uimp [kv] 6 Tripping Class 10 Phase Failure Sensitivity Current Direct Alternating [Hz] Up to 400 Shock Resistance (IEC 60068-2-27; 1/2 sine wave) [g/ms] 10/11 Power Terminals IP Rating Main Terminals Capacity IMOL Yes Yes IP10 Cross/Slotted Combination Stranded / Solid (UL/CSA) [AWG] 14-6 Tightening Torque [lb-in] 20 Environmental Conditions Ambient Temperature Storage: -58 to 176 F (-50 to 80 C), Operating: -4 to 158 C (-20 to 70 C) Pollution Degree 3 Higher Value of Setting Range 3 Weight [lb] 0.33 Auxiliary Contacts Specifications Front Auxiliary Contact Rated Auxiliary Contacts AC-14/15 DC-13/14 UL/CSA 1 NO / 1 NC 24V:4A, 60V:3.5A, 125V:3A, 230V:2A, 400V:1.5A, V:0.5A, 690V:0.3A 24V:1A, 60V:0.5A, 110V:0.25A, 220V:0.1A Rated Thermal Current [A] 6 Short Circuit Protection (Time-delay Fuse ) [A] 6 C600 ; R300 Auxiliary Terminals Capacity [AWG] 16-12 Tightening Torque [lb-in] 13.3 MOTOR CONTROLS www.factorymation.com/motorcontrols ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

100 Standard Contactors & Overloads www.factorymation.com/motorcontrols MOTOR CONTROLS 1 YR WARRANTY 25A Frame Size 7.6 104A 18A Frame Size E468299 3/4HP to 7 DIN rail mountable up to 105A frame UL508 Listed UL and CE Certified IEC 60947 1 year warranty Optional Accessories Include: Additional auxiliary contact blocks Replacement coils Mechanical interlock blocks Link adapters for MMS Coil surge suppression Electronic modules 40A Frame Size 80A Frame Size 105A Frame Size 31 54 14 106 3/4HP 7 Contactors Part Number Price Coil Voltage Aux. Contacts 18A Frame Size IC330-09S-10-AC24 14 24VAC (60Hz) 1 N.O. IC330-09S-10-AC120 14 110/120VAC (50/60Hz) 1 N.O. IC330-09S-10-AC240 14 208-240VAC (60Hz) 1 N.O. IC330-09S-10-AC480 14 400-415/480VAC (50/60Hz) 1 N.O. IC330-09S-10-AC600 14 /600VAC (50/60Hz) 1 N.O. IC330-09S-10-DC24 16 24VDC 1 N.O. IC330-09S-01-DC24 16 24VDC 1 N.C. IC330-12S-10-AC24 16 24VAC (60Hz) 1 N.O. IC330-12S-10-AC120 16 110/120VAC (50/60Hz) 1 N.O. IC330-12S-10-AC240 16 208-240VAC (60Hz) 1 N.O. IC330-12S-10-AC480 16 400-415/480VAC (50/60Hz) 1 N.O. IC330-12S-10-AC600 16 /600VAC (50/60Hz) 1 N.O. IC330-12S-10-DC24 18 24VDC 1 N.O. IC330-12S-01-DC24 18 24VDC 1 N.C. IC330-18S-10-AC24 22 24VAC (60Hz) 1 N.O. IC330-18S-10-AC120 22 110/120VAC (50/60Hz) 1 N.O. IC330-18S-10-AC240 22 208-240VAC (60Hz) 1 N.O. IC330-18S-10-AC480 22 400-415/480VAC (50/60Hz) 1 N.O. IC330-18S-10-AC600 22 /600VAC (50/60Hz) 1 N.O. IC330-18S-10-DC24 25 24VDC 1 N.O. IC330-18S-01-DC24 25 24VDC 1 N.C. 25A Frame Size IC330-25S-00-AC24 24 24VAC (60Hz) - IC330-25S-00-AC120 24 110/120VAC (50/60Hz) - IC330-25S-00-AC240 24 208-240VAC (60Hz) - IC330-25S-00-AC480 24 400-415/480VAC (50/60Hz) - IC330-25S-00-DC24 28 24VDC - 40A Frame Size IC330-32S-00-AC24 31 24VAC (60Hz) - IC330-32S-00-AC120 31 110/120VAC (50/60Hz) - IC330-32S-00-AC240 31 208-240VAC (60Hz) - IC330-32S-00-AC480 31 400-415/480VAC (50/60Hz) - IC330-32S-00-DC28 36 24-28VDC - IC330-40S-00-AC24 39 24VAC (60Hz) - IC330-40S-00-AC120 39 110/120VAC (50/60Hz) - IC330-40S-00-AC240 39 208-240VAC (60Hz) - IC330-40S-00-AC480 39 400-415/480VAC (50/60Hz) - IC330-40S-00-DC28 45 24-28VDC - 80A Frame Size IC330-50S-00-AC24 54 24VAC (60Hz) - IC330-50S-00-AC120 54 110/120VAC (50/60Hz) - IC330-50S-00-AC240 54 208-240VAC (60Hz) - IC330-50S-00-AC480 54 400-415/480VAC (50/60Hz) - IC330-50S-00-DC28 57 24-28VDC - IC330-65S-00-AC24 62 24VAC (60Hz) - IC330-65S-00-AC120 62 110/120VAC (50/60Hz) - IC330-65S-00-AC240 62 208-240VAC (60Hz) - IC330-65S-00-AC480 62 400-415/480VAC (50/60Hz) - IC330-65S-00-DC28 62 24-28VDC - IC330-80S-00-AC24 64 24VAC (60Hz) - IC330-80S-00-AC120 64 110/120VAC (50/60Hz) - IC330-80S-00-AC240 64 208-240VAC (60Hz) - IC330-80S-00-AC480 64 400-415/480VAC (50/60Hz) - IC330-80S-00-DC28 70 24-28VDC - 105A Frame Size IC330-95S-00-AC24 106 24VAC (60Hz) - IC330-95S-00-AC120 106 110/120VAC (50/60Hz) - IC330-95S-00-AC240 106 208-240VAC (60Hz) - IC330-95S-00-AC480 106 400-415/480VAC (50/60Hz) - IC330-95S-00-DC28 111 24-28VDC - IC330-105S-00-AC24 116 24VAC (60Hz) - IC330-105S-00-AC12 0 116 110/120VAC (50/60Hz) - IC330-105S-00-AC240 116 208-240VAC (60Hz) - IC330-105S-00-AC480 116 400-415/480VAC (50/60Hz) - IC330-105S-00-DC28 131 24-28VDC - UL HP Ratings (AC3 Motor Load) Optional Single Phase Three Phase Overload 115V 230V 200V 230V 460V 575V Relay 0.7 1. (9.8A) (10A) 0.7 (13.8A) 1HP (16A) 2HP (24A) (34A) (34A) (56A) (56A) 7. (80A) 7. (80A) 2HP (12A) (17A) (28A) (28A) 7. (40A) 7. (40A) 10HP (50A) 1 (68A) 1 (68A) 10HP 20HP (100A) (88A) (11A) (11A) (9.6A) (9.6A) (17.5A) (15.2A) 7. (25A) 7. (22A) 10HP 10HP (32.2A) (28A) 10HP 1 (32.2A) (42A) 1 1 (48.3A) (42A) 20HP 20HP (62.1A) (54A) 20HP 2 (62.1A) (68A) 2 30HP (78.2A) (80A) 30HP (92A) (7.6A) 7. (11A) 10HP (14A) 1 (21A) 20HP (27A) 30HP (40A) 40HP (52A) 50HP (65A) 50HP (65A) 60HP (77A) 40HP 7 (104A) (96A) 7. (9A) 10HP (11A) 1 (17A) 1 (17A) 2 (27A) 2 (27A) 40HP (41A) 50HP (52A) 60HP (62A) 7 (77A) 7 (77A) IOL-25S IOL-25S IOL-25S IOL-25S IOL-25S IOL-40S IOL-25S IOL-40S IOL-80S IOL-80S IOL-80S IOL- 105S IOL- 105S To Order Call 1.800.972.0436 or Visit factorymation.com

Standard Contactors & Overloads (cont d) 101 1 YR WARRANTY IC330-112L Up to 350HP UL508 Listed UL and CE Certified IEC 60947 1 year warranty Optional Accessories Include: Auxiliary contact blocks Replacement coils 187 99 336A UP TO 350HP 150 to 300A E468299 Part Number Price Coil Voltage Aux. Contacts 150A Frame Size IC330-112L-22-AD28 187 24-28VAC/DC 2 N.O./2 N.C. IC330-112L-22-AD130 187 110-130VAC/DC 2 N.O./2 N.C. IC330-112L-22-AD250 187 208-250VAC/DC 2 N.O./2 N.C. IC330-112L-22-AD 187 430 - VAC/DC 2 N.O./2 N.C. IC330-150L-22-AD28 218 24-28VAC/DC 2 N.O./2 N.C. IC330-150L-22-AD130 218 110-130VAC/DC 2 N.O./2 N.C. IC330-150L-22-AD250 218 208-250VAC/DC 2 N.O./2 N.C. IC330-150L-22-AD 218 430 - VAC/DC 2 N.O./2 N.C. 180A Frame Size IC330-180L-22-AD28 306 24-28VAC/DC 2 N.O./2 N.C. IC330-180L-22-AD130 306 110-130VAC/DC 2 N.O./2 N.C. IC330-180L-22-AD250 306 208-250VAC/DC 2 N.O./2 N.C. IC330-180L-22-AD 306 430 - VAC/DC 2 N.O./2 N.C. 300A Frame Size IC330-250L-22-AD28 434 24-28VAC/DC 2 N.O./2 N.C. IC330-250L-22-AD130 434 110-130VAC/DC 2 N.O./2 N.C. IC330-250L-22-AD250 434 208-250VAC/DC 2 N.O./2 N.C. IC330-250L-22-AD 434 430 - VAC/DC 2 N.O./2 N.C. IC330-300L-22-AD28 451 24-28VAC/DC 2 N.O./2 N.C. IC330-300L-22-AD130 451 110-130VAC/DC 2 N.O./2 N.C. IC330-300L-22-AD250 451 208-250VAC/DC 2 N.O./2 N.C. IC330-300L-22-AD 451 430 - VAC/DC 2 N.O./2 N.C. UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 200V 230V 460V 575V - - - - - - - - - - 40HP (120A) 50HP (150A) 60HP (177A) Optional Overload Relay 50HP 100HP 100HP IOL-150L (130A) (124A) (99A) 60HP 12 150HP IOL-150L (154A) (156A) (144A) 7 150HP 200HP IOL-180L (192A) (180A) (192A) 7 100HP 200HP 250HP IOL-300L (221A) (248A) (240A) (242A) 100HP 12 250HP 350HP IOL-300L (285A) (312A) (302A) (336A) MOTOR CONTROLS Contactor Accessories Part Number Price Description Auxiliary Contacts ICA-AUX-F10 3 Front Mount, 1NO, for ICxxx-09S to -105S contactors ICA-AUX-F01 3 Front Mount, 1NC, for ICxxx-09S to -105S contactors ICA-AUX-S11 6 Side Mount, 1NO/1NC for ICxxx-09S to ICxxx-300L contactors ICA-AUX-S20 6 Side Mount, 2NO, for ICxxx-09S to ICxxx-300L contactors ICA-AUX-S11X 6 Side Mount, 2nd Block, 1NO/1NC, for ICxxx-09S to ICxxx-300L contactors ICA-AUX-S20X 6 Side Mount, 2nd Block, 2NO, for ICxxx-09S to ICxxx-300L contactors Mechanical Interlock Blocks ICA-MECINT02-105F 11 Side mount between two ICxxx-09S to ICxxx-105S contactors Side mount between two ICxxx-112L to ICxxx-300L contactors w/ ICA-MECINT00-300F 22 the same frame size Link Adapters (Electrical and Mechanical Direct Connection) IMA-LNKADP-32F-25C 7 For IMM32 + ICxxx-09S to ICxxx-25S (IC contactor AC Coils Only) IMA-LNKADP-32F-40C 7 For IMM32 + ICxxx-32S to ICxxx-40S (IC contactor AC Coils Only) Lug Terminals ICA-LUGS-150F FMX Lugs for ICxxx-112L to ICxxx-150L, 300 MCM to 6 AWG wire 22 size, 3 pack ICA-LUGS-180F 26 FMX Lugs for ICxxx-180L, 300 MCM to 6 AWG wire size, 3 pack ICA-LUGS-300F FMX Lugs for ICxxx-250S to ICxxx-300L, 300 MCM to 6 AWG wire 46 size, 3 pack Surge Suppressors ICA-VARSURG-105F-AC510 6 Varistor, ICxxx-09S to ICxxx-105S, 400 to 510VAC ICA-RCSURG-40F-AC48 8 RC, ICxxx-09S to ICxxx-40S, 24 to 48VAC ICA-RCSURG-40F-AC127 8 RC, ICxxx-09S to ICxxx-40S, 50 to 127VAC ICA-RCSURG-40F-AC250 8 RC, ICxxx-09S to ICxxx-40S, 130 to 250VAC ICA-RCSURG-105F-AC48 8 RC, ICxxx-50S to ICxxx-105S, 24 to 48VAC ICA-RCSURG-105F-AC127 8 RC, ICxxx-50S to ICxxx-105S, 50 to 127VAC ICA-RCSURG-105F-AC250 8 RC, ICxxx-50S to ICxxx-105S, 130 to 250VAC ICA-RCSURG-250F-AC48 8 RC, ICxxx-112L to ICxxx-250L, 24 to 48VAC ICA-RCSURG-250F-AC250 8 RC, ICxxx-112L to ICxxx-250L, 50 to 250VAC ICA-DIODE-25F-DC600 8 Diode, ICxxx-09S to ICxxx-25S, 12 to 600VDC Part Number Price Description Replacement Contactor Coils ICR-COIL-25F-AC24 9 ICxxx-09 to ICxxx-25, 24VAC, 60Hz ICR-COIL-25F-AC120 9 ICxxx-09 to ICxxx-25, 110/120VAC, 50/60Hz ICR-COIL-25F-AC240 9 ICxxx-09 to ICxxx-25, 208-240VAC, 60Hz ICR-COIL-25F-AC480 9 ICxxx-09 to ICxxx-25, 400-415/480VAC, 50/60Hz ICR-COIL-25F-AC600 9 ICxxx-09 to ICxxx-25, /600VAC, 50/60Hz ICR-COIL-25F-DC24 14 ICxxx-09 to ICxxx-25, 24VDC ICR-COIL-40F-AC24 10 ICxxx-32 to ICxxx-40, 24VAC, 60Hz ICR-COIL-40F-AC120 10 ICxxx-32 to ICxxx-40, 110/120VAC, 50/60Hz ICR-COIL-40F-AC240 10 ICxxx-32 to ICxxx-40, 208-240VAC, 60Hz ICR-COIL-40F-AC480 10 ICxxx-32 to ICxxx-40, 400-415/480VAC, 50/60Hz ICR-COIL-40F-AC600 10 ICxxx-32 to ICxxx-40, /600VAC, 50/60Hz ICR-COIL-40F-DC24 16 ICxxx-32 to ICxxx-40, 24VDC ICR-COIL-40F-DF240 10 ICxxx-32 to ICxxx-40, 208/240VAC, 50/60Hz ICR-COIL-105F-AC120 14 ICxxx-50 to ICxxx-105, 110/120VAC, 50/60Hz ICR-COIL-105F-AC240 14 ICxxx-50 to ICxxx-105, 208-240VAC, 60Hz ICR-COIL-105F-AC480 14 ICxxx-50 to ICxxx-105, 400-415/480VAC, 50/60Hz ICR-COIL-105F-AC600 14 ICxxx-50 to ICxxx-105, /600VAC, 50/60Hz ICR-COIL-105F-DC24 21 ICxxx-50 to ICxxx-105, 24VDC Replacement Contactor Coils 150-300A Frame ICR-COIL-150F-AD28* 20 ICxxx-112 to ICxxx-150, 24-28VAC/DC*Use w/icr-emod-300f-ad28* ICR-COIL-150F-AD130* 20 ICxxx-112 to ICxxx-150,110-130VAC/DC*Use w/icr-emod-300f-ad130* ICR-COIL-150F-AD250* 20 ICxxx-112 to ICxxx-150, 208-250VAC/DC*Use w/icr-emod-300f-ad250* ICR-COIL-150F-AD* 20 ICxxx-112 to ICxxx-150, 430-VAC/DC*Use w/icr-emod-300f-ad* ICR-COIL-180F-AD28* 26 ICxxx-180L, 24-28VAC/DC*Use w/icr-emod-300f-ad28* ICR-COIL-180F-AD130* 26 ICxxx-180L,110-130VAC/DC*Use w/icr-emod-300f-ad130* ICR-COIL-180F-AD250* 26 ICxxx-180L, 208-250VAC/DC*Use w/icr-emod-300f-ad250* ICR-COIL-180F-AD* 26 ICxxx-180L, 430-VAC/DC*Use w/icr-emod-300f-ad* ICR-COIL-300F-AD28* 33 ICxxx-250 to ICxxx-300, 24-28VAC/DC*Use w/icr-emod-300f-ad28* ICR-COIL-300F-AD130* 33 ICxxx-250 to ICxxx-300,110-130VAC/DC*Use w/icr-emod-300f-ad130* ICR-COIL-300F-AD250* 33 ICxxx-250 to ICxxx-300, 208-250VAC/DC*Use w/icr-emod-300f-ad250* ICR-COIL-300F-AD* 33 ICxxx-250 to ICxxx-300, 430-VAC/DC*Use w/icr-emod-300f-ad* Replacement Electronic Modules ICR-EMOD-300F-AD28* 71 ICxxx-112 to ICxxx-300, 24-28VAC/DC*Use w/ ICR-COIL-xxxx-AD28* ICR-EMOD-300F-AD130* 71 ICxxx-112 to ICxxx-300,110-130VAC/DC*Use w/ ICR-COIL-xxxx-AD130* ICR-EMOD-300F-AD250* 71 ICxxx-112 to ICxxx-300, 208-250VAC/DC*Use w/ ICR-COIL-xxxx-AD250* ICR-EMOD-300F-AD* 71 ICxxx-112 to ICxxx-300, 430-VAC/DC*Use w/ ICR-COIL-xxxx-AD* *Replacement Coils 112A and above must be paired with an Electronic Module www.factorymation.com/motorcontrols ICA-AUX-F10 ICA-AUX-S11 IMA-LNKADP-32F Lug Terminals Surge Suppressor ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

102 Standard Contactors & Overloads (cont d) 18 Thermal Overload Relays 3-pole Overloads 2-pole Overloads Price Aux Contacts Current Range Applicable Contactor www.factorymation.com/motorcontrols MOTOR CONTROLS 1 YR WARRANTY IOL-25S Trip ranges from 0.28A to 420A Separate mount adapter available (through IOL-105S) Ambient compensated -4 to 140 F (-20 to 60 C) Selectable RESET button (auto or manual) Differential current / phase loss protection Isolated 1N.O. & 1 N.C. auxiliary contacts Trip class 10 UL and CE Certified UL508 / IEC 60947 1 year warranty IOL-80S IOL-105S IOL-40S 37 54 0.28 420A E468296 IOL-25S-P40 IOLS-25S-P40 18 1 N.O. / 1N.C. 0.28-.040A IOL-25S-P63 IOLS-25S-P63 18 1 N.O. / 1N.C 0.40-0.63A IOL-25S-P80 IOLS-25S-P80 18 1 N.O. / 1N.C. 0.56-0.8A IOL-25S-1P2 IOLS-25S-1P2 18 1 N.O. / 1N.C 0.8-1.2A IOL-25S-1P8 IOLS-25S-1P8 18 1 N.O. / 1N.C. 1.2-1.8A IOL-25S-2P8 IOLS-25S-2P8 18 1 N.O. / 1N.C 1.8-2.8A IOL-25S-4P0 IOLS-25S-4P0 18 1 N.O. / 1N.C. 2.8-4.0A IOL-25S-6P3 IOLS-25S-6P3 18 1 N.O. / 1N.C 4.0-6.3A IOL-25S-8P0 IOLS-25S-8P0 18 1 N.O. / 1N.C. 5.6-8.0A IOL-25S-010 IOLS-25S-010 18 1 N.O. / 1N.C 7-10A IOL-25S-012 IOLS-25S-012 18 1 N.O. / 1N.C. 8-12.5A IOL-25S-015 IOLS-25S-015 18 1 N.O. / 1N.C 10-15A IOL-25S-017 IOLS-25S-017 18 1 N.O. / 1N.C. 11-17A IOL-25S-023 IOLS-25S-023 18 1 N.O. / 1N.C. 15-23A IOL-25S-032 IOLS-25S-032 18 1 N.O. / 1N.C 22-32A ICxxx-09S ICxxx-12S ICxxx-18S ICxxx-25S ICxxx-09S ICxxx-12S ICxxx-18S ICxxx-25S ICxxx-32S ICxxx-40S IOL-40S-040 IOLS-40S-040 33 1 N.O. / 1N.C. 25-40A ICxxx-32S IOL-40S-050 IOLS-40S-050 33 1 N.O. / 1N.C 32-50A ICxxx-40S IOL-80S-040 IOLS-80S-040 37 1 N.O. / 1N.C 25-40A IOL-80S-050 IOLS-80S-050 37 1 N.O. / 1N.C. 32-50A IOL-80S-057 IOLS-80S-057 37 1 N.O. / 1N.C 40-57A IOL-80S-063 IOLS-80S-063 37 1 N.O. / 1N.C. 50-63A IOL-80S-070 IOLS-80S-070 40 1 N.O. / 1N.C. 57-70A IOL-80S-080 IOLS-80S-080 40 1 N.O. / 1N.C. 63-80A IOL-105S-080-54 1 N.O. / 1N.C 63-80A IOL-105S-097-54 1 N.O. / 1N.C. 75-97A IOL-105S-112-54 1 N.O. / 1N.C 90-112A IOL-150L-097-LK - 130 1 N.O. / 1N.C 75-97A IOL-150L-112-LK - 130 1 N.O. / 1N.C 90-112A IOL-150L-150-LK - 132 1 N.O. / 1N.C 100-150A IOL-150L-215-LK - 132 1 N.O. / 1N.C 140-215A IOL-180L-150-LK - 132 1 N.O. / 1N.C 100-150A IOL-180L-215-LK - 132 1 N.O. / 1N.C 140-215A IOL-300L-150-LK - 148 1 N.O. / 1N.C 100-150A IOL-300L-215-LK - 148 1 N.O. / 1N.C 140-215A IOL-300L-310-LK - 179 1 N.O. / 1N.C 200-310A IOL-300L-420-LK - 179 1 N.O. / 1N.C 275-420A Overload Accessories Part Number Price Description Separate Mount Block IHA-SMB-32F 6 For IOL-25S & IOLS-25S IHA-SMB-50F 8 For IOL-40S & IOLS-40S IHA-SMB-80F 8 For IOL-80S & IOLS-80S IHA-SMB-105F 10 For IOL-105L Lug Terminals IHA-LUGS-215 22 For IOL-300L-150 & IOL-300L-215, 3 pack IHA-LUGS-420 46 For IOL-300L-310 & IOL-300L-420, 3 pack IHA-LUGSPCR 4 Spacers for IHA-LUGS-215 & IHA-LUGS-420 (required for UL) ICxxx-50S ICxxx-65S ICxxx-80S ICxxx-95S ICxxx-105S ICxxx-112L ICxxx-150L ICxxx-180L ICxxx-250L ICxxx-300L 130 separate mount block Lug Terminals IOL-150L To Order Call 1.800.972.0436 or Visit factorymation.com

Standard Contactors & Overloads (cont d) 103 Contactor Dimension Legend in(mm) Overload Dimension Legend in(mm) W H D D H MOTOR CONTROLS Contactor Dimensions Contactor Frame Size Contactor Specifications Contactor ICxxx-09S ICxxx-12S ICxxx-18S ICxxx-25S ICxxx-32S ICxxx-40S ICxxx-50S ICxxx-65S ICxxx-80S ICxxx-95S ICxxx-105S Rated Insulation Voltage (V) UL/CSA: 600, IEC/VDE 0660: 1000 Rated Impulse Voltage IEC60947-1 (kv) 6 6 6 6 6 6 8 8 8 8 8 Rated Operating Frequency (Hz) 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 Degree of Protection Vibration Resistance (5 to 200Hz) Mechanical Endurance Electrical Endurance Shock Resistance: 1/2 Sin Wave = 11ms Main Terminals IP20 IP20 IP20 IP10 IP10 IP10 IP10 IP10 IP10 IP10 IP10 Coil Terminals IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 Auxiliary Terminals IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 Contactor Open (g) 3 3 3 4.5 7 7 4.5 4.5 4.5 5 5 Contactor Closed at (g) 6 6 6 5 9 9 9 9 9 7 7 AC Coil (Million ops) 10 10 10 10 10 10 10 10 10 10 10 AC-3 (Million ops) 1.8 1.6 1.2 1.3 1.2 1.2 1.1 1.3 1.1 1.1 1.0 Contactor Open 8 8 8 8 7 7 6 6 6 6 6 Contactor Closed at Coil 12 12 12 12 12 12 10 10 10 10 10 Stranded/Solid 1 or 2 1 or 2 1 or 2 1 or 2 Terminal Capacity (AWG) 14-8 14-8 14-1/0 14-1/0 14-1/0 14-1/0 14-1/0 (UL/CSA) (14-10) (14-10) (14-10) (14-8) Screw Driver Philips #2 Philips #2 Philips #2 Philips #2 Philips #2 Philips #2 5/32 5/32 5/32 5/32 5/32 Tightening Torque (lb-in) 15 15 15 16 22 22 40 40 40 60 60 Environmental Conditions Ambient Temperature Storage: -67 to 176 F (-55 to 80 C), Operating (IEC) -13 to 131 F (-25 to 55 C) Climatic Withstand According to IEC 60680-2 Pollution Degree 3 Mounting 35mm DIN-rail Acc. DIN EN 50 022 Weight (lbs) 0.65 0.65 0.65 0.65 1.15 1.19 2.44 2.47 2.49 3.20 3.24 Warranty Control Circuit Ratings (AC/DC COIL) Standard Voltages 24 to 600VAC / 24 to VDC 24 to 600 (AC) / 24 to 240 24 to 600 (AC) / 24 to 240 (DC) Coil Operating Limits Coil Consumption (Single Coils) Monofrequency Coils (V) 0.85 to 1.1 (AC) 0.85 to 1.1 (AC) 0.85 to 1.1 (AC) Pick-up (V) 0.4 to 0.76 (AC/DC) 0.5 to 0.8 (AC/DC) 0.5 to 0.8 (AC) / 0.7 to 0.8 (DC) Drop-out (V) 0.25 to 0.65 (AC) / 0.15 to 0.4 (DC) 0.2 to 0.6 (AC) / 0.4 to 0.6 0.2 to 0.6 (AC) / 0.4 to 0.6 (DC) Sealed (VA) 4.0 to 7.2 (AC) / 3.8 to 7.5 (DC) 9.2 to 12.5 (AC) / 6.0 (DC) 16.5 to 25 (AC) / 6.5 (DC) Inrush (VA) 70.0 (AC) / 3.8 to 7.5 (DC) 115 (AC) / 240 (DC) 295 (AC) / 340 (DC) Heat Loss (W) 2.6 4.3 8.0 Power Factor Operating Time H W D in mm in mm in mm 18A (AC) 3.189 81.0 1.772 45.0 3.362 85.4 18A (DC) 3.189 81.0 1.772 45.0 4.547 115.5 25A (AC) 3.189 81.0 1.772 45.0 3.425 87.0 25A (DC) 3.189 81.0 1.772 45.0 4.606 117.0 40A (AC) 3.524 89.5 2.165 55.5 3.852 97.9 40A (DC) 3.524 89.5 2.165 55.5 4.640 117.9 80A (AC/DC) 4.58 116.3 2.60 66.0 4.53 115.0 105A (AC/DC) 4.58 116.3 2.97 75.4 4.97 126.2 150A (AC/DC) 6.3 160.0 4.8 121.5 5.7 145.0 180A (AC/DC) 7.2 183.0 5.5 139.0 6.7 170.0 300A (AC/DC) 7.8 198.0 5.8 147.5 7.1 181.0 Overload Dimensions Overload H W D in mm in mm in mm IOL-25S 2.0 51.5 1.8 45 3.3 82.5 IOL-40S/-80S 3.0 76.0 2.0 50.0 4.2 106.0 IOL-105S 3.9 99.5 3.0 75.0 3.9 98.5 IOL-150L-097-LK IOL-150L-112-LK IOL-150L-150-LK IOL-150L-215-LK 4.6 116.4 3.0 75.0 4.2 106.2 6.8 172.72 4.75 120.65 7.3 185.42 IOL-180L 6.8 172.72 4.75 120.65 7.3 185.42 IOL-300L 6.8 172.72 4.75 120.65 7.3 185.42 Closed Cos Φ 0.28 0.34 0.32 Opened Cos Φ 0.85 0.69 0.54 Coil Energization-N.O. (ms) 35 to 45 (DC) 50 to 60 (DC) 50 to 60 (DC) Coil De-energization-N.O. (ms) 7 to 12 (DC) 55 to 60 (DC) 55 to 60 (DC) 1 year www.factorymation.com/motorcontrols ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

104 Standard Contactors & Overloads (cont d) www.factorymation.com/motorcontrols MOTOR CONTROLS Contactor Specifications (cont d) Contactor ICxxx-112L ICxxx-150L ICxxx-180L ICxxx-250L ICxxx-300L Rated Insulation Voltage (V) UL/CSA: 600, IEC/VDE 0660: 1000 Rated Impulse Voltage IEC60947-1 (kv) 8 8 8 8 8 Rated Operating Frequency (Hz) 25 to 400 25 to 400 25 to 400 25 to 400 25 to 400 Degree of Protection Vibration Resistance (5 to 200Hz) Overload IOL-25S IOL-40S/80S IOL-105S/150L IOL-300L Number of Poles 3 Rated Operation & Insulation Voltage IEC 60947-4-1 [V] 690 1000 UL; CSA [V] 600 Rated Impulse Voltage [kv] 6 8 Tripping Class 10 Phase Failure Sensitivity Current Ambient Temperature Main Terminals IP00 IP00 IP00 IP00 IP00 Coil Terminals IP20 IP20 IP20 IP20 IP20 Auxiliary Terminals IP20 IP20 IP20 IP20 IP20 Contactor Open (g) 4 4 4 4 4 Contactor Closed at Coil (g) 4 4 4 4 4 Mechanical Endurance AC Coil (Million ops) 10 10 10 10 10 Electrical Endurance AC-3 (Million ops) 1.1 1.0 1.0 1.0 1.0 Shock Resistance (1/2 Sin Wave = 11ms) Terminal Capacity Contactor Open 3 3 3 3 3 Contactor Closed at Coil 3 3 3 3 3 Wires w/end Sleeve (AWG) 1 x 300 or 2 x 107 1 x 300 or 2 x 107 1 x 300 or 2 x 107 1 x or 2 x 300 1 x or 2 x 300 Fine - Stranded w/sleeve (mm2) 2 x (25-70) 2 x (25-70) 2 x (50-120) 2 x (50-150) 2 x (50-150) Busbars (mm) 2 x (15x3) 2 x (15x3) 2 x (20x3) 2 x (30x5) 2 x (30x5) Screw Driver Philips #2 Philips #2 Philips #2 Philips #2 Philips #2 Tightening Torque (lb-in) 47.8-53.1 47.8-53.1 123.9-141.6 203.6-230.1 203.6-230.1 Environmental Conditions Ambient Temperature Direct YES NO Alternating [Hz] Up to 400 50/60 Storage Operating Storage: -67 to 176 F (-55 to 80 C), Operating (IEC) -13 to 131 F (-25 to 55 C) Climatic Withstand According to IEC 68-2 Pollution Degree 3 Mounting Screw to panel Weight (lbs) 0.65 0.65 0.65 0.65 1.15 Warranty Electronic Control Module Control Circuit Ratings (AC/DC COIL) Standard Voltages (V) UL/CSA: 600, IEC/VDE 0660: 1000 Coil Operating Limits Coil Consumption (Single Coils) YES -58 to 176 F (-50 to 80 C) -4 to 158 F (-20 to 70 C) Pollution Degree 3 Current Heat Loss [W] 3 5.5 5.5 15 Weight [lb] 0.32 0.68 1.00/1.45 3.95 Shock Resistance (IEC 60068-2-27; 1/2 Sine Wave) [g/ms] 10/11 Standards IEC 60947-1 / 60947-4-1, UL 508; CSA C.22.2/14; VDE 0660/102 Power Terminals IP Rating IP10 IP00 Main Terminals Capacity Cross/Slotted Combination Allen Head Slide Bar Stranded / Solid (UL/CSA) 75 C, Cu Only [AWG] 14-6 18-2 8-1/0 8-1/0 Tightening Torque [lb-in] 20 35 53 141 (100-215A) 230 (200-420A) 1 year Monofrequency Coils (V) 24 to Pick-up (V) 0.65 to 1.1 Drop-out (V) 0.70 to 0.85 Sealed (VA) 0.40 to 0.60 Inrush (VA) 40 to 85 Heat Loss (W) 50 to 75 Coil Consumption Sealed (VA/W) 14.8 (AC) / 2.4 (DC) 14.8 (AC) / 2.4 (DC) 14.1 (AC) / 2.4 (DC) 14.1 (AC) / 2.5 (DC) 14.1 (AC) / 2.5 (DC) Inrush (VA/W) 213 (AC) / 166 (DC) 213 (AC) / 166 (DC) 214 (AC) / 154 (DC) 229 (AC) / 171 (DC) 229 (AC) / 171 (DC) Heat Loss (W) 3.9 (AC) 2.4 (DC) 3.9 (AC) 2.4 (DC) 3.8 (AC) /2.4 (DC) 3.7 (AC) /2.5 (DC) 3.7 (AC) /2.5 (DC) Overload Specifications To Order Call 1.800.972.0436 or Visit factorymation.com

Manual Motor Starters 105 Formerly LG Industrial Systems E252942 C US 42 0.1 100A HIGH SCCR SERIES High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal overload protection Trip test feature Part Number Price Single Phase UL HP Ratings Three Phase Phase loss protection Complies with IEC 60947-2 and IEC 60947-4- 1 UL508 (Manual motor controller) UL508 (Combination motor controller starter) CSA C22.2 NO.14 GB14048 Thermal Adjustable Range (A) Short Circuit Current Rating (SCCR) 115V 230V 200V 230V 460V 575V 240V 480V 600V MOTOR CONTROLS MMS-32H Frame 32 Amp Frame MMS-32H-0.16A 42 0.1-0.16A 100kA 65kA 25kA MMS-32H-0.25A 42 0.16-0.25A 100kA 65kA 25kA MMS-32H-0.4A 42 0.25-0.4A 100kA 65kA 25kA MMS-32H-0.63A 42 0.4-0.63A 100kA 65kA 25kA MMS-32H-1A 42 1/2 0.63-1.0A 100kA 65kA 25kA MMS-32H-1.6A 47 1/10 3/4 3/4 1.0-1.6A 100kA 65kA 25kA MMS-32H-2.5A 47 1/6 1/2 1/2 1 1-1/2 1.6-2.5A 100kA 65kA 25kA MMS-32H-4A 50 1/8 1/3 3/4 3/4 2 3 2.5-4.0A 100kA 65kA 25kA 45mm MMS-63H Frame MMS-32H-6A 50 1/4 1/2 1 1-1/2 3 5 4-6A 100kA 65kA 25kA MMS-32H-8A 50 1/3 1 2 2 5 5 5-8A 100kA 65kA 25kA MMS-32H-10A 50 1/2 1-1/2 2 3 5 7-1/2 6-10A 100kA 65kA 25kA MMS-32H-13A 50 1/2 2 3 3 7-1/2 10 9-13A 100kA 65kA 25kA MMS-32H-17A 50 1 3 3 5 10 15 11-17A 100kA 30kA 10kA MMS-32H-22A 50 1-1/2 3 5 7-1/2 15 20 14-22A 100kA 30kA 10kA MMS-32H-26A 50 2 3 7-1/2 7-1/2 15 20 18-26A 100kA 30kA 10kA MMS-32H-32A 50 2 5 7-1/2 10 20 30 22-32A 100kA 30kA 10kA MMS-32H-40A 50 3 7-1/2 10 10 30 30 28-40A 100kA 30kA 10kA 63 Amp Frame MMS-63H-17A 123 1 3 3 5 10 15 11-17A 100kA 50kA 10kA www.factorymation.com/motorcontrols MMS-63H-22A 123 1-1/2 3 5 7-1/2 15 20 14-22A 100kA 50kA 10kA MMS-63H-26A 123 2 3 7-1/2 7-1/2 15 20 18-26A 100kA 50kA 10kA 55mm MMS-63H-32A 123 2 5 7-1/2 10 20 30 22-32A 100kA 50kA 10kA MMS-63H-40A 123 3 7-1/2 10 10 30 30 28-40A 100kA 50kA 10kA MMS-100H Frame MMS-63H-50A 119 3 10 15 15 30 40 34-50A 100kA 50kA 10kA MMS-63H-63A 119 5 10 20 20 40 60 45-63A 100kA 50kA 10kA 100 Amp Frame MMS-100H-75A 209 5 15 20 25 50 60 55-75A 100kA 50kA 10kA MMS-100H-90A 205 7-1/2 20 25 30 60 75 70-90A 100kA 50kA 10kA MMS-100H-100A 205 10 20 30 30 75 100 80-100A 100kA 50kA 10kA 70mm ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

106 Manual Motor Starter Accessories Extended Rotary Handle Formerly LG Industrial Systems www.factorymation.com/motorcontrols MOTOR CONTROLS Shown attached to Manual Motor Starter (sold separately) UL Type 12, IP65 rating Available with 4.53 (115mm) or 12.4 (315mm) shaft lengths MMS Bus Bars For parallel connection with MMS power terminals Simplifies wiring and reduces wiring space Multiple bus bars can be combined providing total current rating is not exceeded MMS Auxiliary Contact Blocks Front mount auxiliary blocks Side mount auxiliary, alarm, undervoltage, and shunt trip contact blocks Front Mount TYPE 12 / IP65 PROTECTION E252942 Part Number Price Description MMS-FX-11 9 Auxiliary Contacts, front mounting, 1 N.O., 1 N.C. MMS-FX-20 9 Auxiliary Contacts, front mounting, 2 N.O. MMS-FX-02 9 Auxiliary Contacts, front mounting, 2 N.C. MMS-LX-11 11 Auxiliary Contacts, side mounting, 1 N.O., 1N.C. MMS-LX-20 11 Auxiliary Contacts, side mounting, 2 N.O. MMS-LX-02 11 Auxiliary Contacts, side mounting, 2 N.C. MMS-LA 14 Trip Alarm Switch, signals all faults, side mounting, 1N.O., 1N.C. for MMS-32H MMS-LA-11-63 14 Trip Alarm Switch, side mounting, 1N.O., 1N.C. for use with MMS63H & MMS100H MMS-LAM 15 Magnetic Trip Alarm Switch, signals magnetic trip only, side mounting, 1N.O., 1N.C. contact MMS-RS-28 21 Shunt Release, side mounting, 24V/50Hz, 28V/60Hz MMS-RS-120 21 Shunt Release, side mounting, 110V/50Hz, 120V/60Hz MMS-RS-220 21 Shunt Release, side mounting, 200V/50Hz, 200-220V/60Hz MMS-RS-480 21 Shunt Release, side mounting, 415-440V/50Hz, 460-480V/60Hz MMS-RU-28 21 Undervoltage Release, side mounting, 24V/50Hz, 28V/60Hz MMS-RU-120 21 Undervoltage Release, side mounting, 110V/50Hz, 120V/60Hz MMS-RU-240 21 Undervoltage Release, side mounting, 200V/50Hz, 200-220V/60Hz MMS-RU-480 21 Undervoltage Release, side mounting, 415-440V/50Hz, 460-480V/60Hz MMS-RUX-28 26 Undervoltage Release with Switch, side mounting, 2 N.O. Contacts, 24V/50Hz, 28V/60Hz MMS-RUX-120 26 Undervoltage Release with Switch, side mounting, 2 N.O. Contacts, 110V/50Hz, 120V/60Hz MMS-RUX-480 26 Undervoltage Release with Switch, side mounting, 2 N.O. Contacts, 415-440V/50Hz, 460-480V/60Hz MMS-MEH32-115R 21 Extended Rotary Handle and shaft, for use with MMS-32H, UL Type 3R/IP65, 4.53" (115mm) shaft length MMS-MEH32-315R 23 Extended Rotary Handle and shaft, for use with MMS-32H, UL Type 3R/IP65, 12.4 (315mm) shaft length MMS-MEH63-115R 21 Extended Rotary Handle and shaft, for use with MMS-63H, UL Type 12/IP65, 4.53" (115mm) shaft length MMS-MEH63-315R 23 Extended Rotary Handle and shaft, for use with MMS-63H, UL Type 12/IP65, 12.4 (315mm) shaft length MMS-MEH100-115R 21 Extended Rotary Handle and shaft, for use with MMS-100H, UL Type 12/IP65, 4.53" (115mm) shaft length MMS-MEH100-315R 23 Extended Rotary Handle and shaft, for use with MMS-100H, UL Type12/IP65, 12.4 (315mm) shaft length MMS-PB-322 8 Phase Bus Bar for 32 Amp Frame, 63 amp maximum current, connects two MMS s MMS-PB-323 12 Phase Bus Bar for 32 Amp Frame, 63 amp maximum current, connects three MMS s MMS-PB-632 12 Phase Bus Bar for 63 Amp Frame, 108 amp maximum current, connects two MMS s MMS-PB-633 16 Phase Bus Bar for 63 Amp Frame, 108 amp maximum current, connects three MMS s MMS-EPH32-65S 21 Plastic Enclosure w/ rotary handle, compatible with MMS-32H, UL Type 1/IP65, UL and CE certified, suitable for surface mounting CG-M20-1014-5 4.50 M20x1.5, Cord Grip (IP68), 5-pack, cable size: 0.39-0.55" (10-14 mm) CG-M20-0612-5 4.50 M20x1.5, Cord Grip (IP68), 5-pack, cable size: 0.24-0.47" (6-12 mm) Plastic MMS Enclosure TYPE 1 / IP65 PROTECTION Dimensions in(mm) 6.38 (162) 5.91 (150) 4.21 (107) E232064 Left Side Position 2 Left Side Position 1 MMS-FX-xx Right Side MMS-EPH32-65S UL Type 1, IP65 rating Rotary handle with lockout provision UL and CE certified Available for 32 amp frame only M20/M25 knockouts 4.13 (105) 1.81 (46) MMS-LX-xx MMS-LX-xx or MMS-LA or MMS-LAM MMS-RS-xxx or MMS-RU-xxx or MMS-RUX-xxx To Order Call 1.800.972.0436 or Visit factorymation.com

107 Formerly LG Industrial Systems MMS Terminal Specifications General Specifications 32 Amp Frame 63 Amp Frame 100 Amp Frame Wire Type Conductors MMS-32H MMS-63H MMS-100H 1 18-8 AWG 18-2 AWG 12-2/0 AWG Solid 2 18-10 AWG 18-4 AWG 12-1/ 0 AWG 1 18-10 AWG 18-2 AWG 12-2/0 AWG Stranded 2 18-10 AWG 18-4 AWG 12-1/ 0 AWG 1 18-10 AWG 18-4 AWG 12-1/0 AWG Flexible 2 18-10 AWG 18-6 AWG 10-2 AWG Torque 7-22 lb-in 26-39 lb-in 35-53 lb-in Trip Characteristics MMS-32 MMS-63, 100 Standards Rated Operational Voltage (Ue) Rated Frequency Manual Motor Starter Dimensions in(mm) B A Underwriters Laboratories - UL 508, File # E252942; CSA C22.2, IEC 60947-2 & IEC 60947-4-1 Compliance Up to 690V 50/60Hz Rated Insulation Voltage (Ui) 32AF: 690V; 63AF - 100AF: 1,000V Rated Impulse Voltage (Uimp) Utilization Category 32AF: 6kV; 63AF - 100AF: 8kV IEC 60 947-2 (Breaker): Cat. A; IEC 60 947-4 (Motor starter) AC 3 Mechanical Endurance (Ops) 32AF: 100,000; 63AF - 100AF: 50,000 Electrical Endurance (Ops) 32AF: 100,000; 63AF - 100AF: 25,000 Max Operating Frequency Storage Temperature Operating Temperature Phase Loss Protection Degree of Protection Resistance to Shock Resistance to Vibration Terminal Capacity Tightening Torque Manual Motor Starter 25 operations/hour -58 to 176 F (-50 to 80 C) -4 to 140 F (-20 to 60 C) Yes IP20 25g 5-150Hz 32AF: 1 or 2 x (18-10 AWG); 63AF: 1 x (18-2 AWG) or 2 x (18-4 AWG); 100AF: 1 x (12-2/0 AWG) or 2 x (12-1/0 AWG) 32AF:.8-2.5 Nm (7-22lb-in); 63AF: 3-4.5 Nm (26-39lb-in); 100AF: 4-6 Nm (35-53lb-in) Inches (mm) A B C MMS-32H 1.8 (45) 3.7 (94) 3.9 (99.6) MMS-63H 2.2 (55) 5.5 (140) 5.7 (144.6) MMS-100H 2.8 (70) 6.5 (165) 6.7 (171) C MOTOR CONTROLS www.factorymation.com/motorcontrols Extended Rotary Handle Dimensions in(mm) A E-Handle Type A Min Max Inches (mm) MEH32-115R 5.9 8.3 (148.6 210.6) MEH32-315R 5.9 16.2 (148.6 410.6) MEH63-115 7.6 10.1 (193.6 255.6) MEH63-315 7.6 17.9 (193.6 455.6) MEH100-115 8.7 11.1 (220 282) MEH100-315 8.7 18.9 (220 482) MMS Type MMS-32H MMS-63H MMS-100H ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

108 Mini Contactors & Overloads www.factorymation.com/motorcontrols MOTOR CONTROLS GMC-12M Surface or DIN rail mountable UL508 compliant 1/2HP to 7-1/2HP 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.) UL and CE certified IEC 60947 Optional Accessories Include: Additional auxiliary contact blocks Reverse mounting kits and interlocks Time delay units Surge suppressors Direct mount to Manual Motor Starter (with optional adapter) Full Featured Contactor and Overload Top Mount Aux Contact Position Identification Labels Dial Trip Setting Finger Safe Terminals 13 3.9 16A E108780 0. 7. Aux Contacts (1 N.O.) Side Mount Aux Contact Position Reset Button Selector Trip Indicator Built-in Aux Contacts (1 N.O., 1 N.C.) MetaMec Mini Contactors (6-12A) Part Number Price Coil Voltage 6 Amp, Screw Terminals GMC-6M-10-24 13 24VAC (50/60Hz AC) GMC-6M-10-120 13 120VAC (50/60Hz AC) GMC-6M-10-208 13 200-208VAC (50/60Hz GMC-6M-10-230 13 230-240VAC (50/60Hz GMC-6M-10-480 13 480VAC (50/60Hz AC) GMD-6M-10-12 16 12VDC GMD-6M-10-24 16 24VDC 9 Amp, Screw Terminals GMC-9M-10-24 14 24VAC (50/60Hz AC) GMC-9M-10-120 14 120VAC (50/60Hz AC) GMC-9M-10-208 14 200-208VAC (50/60Hz GMC-9M-10-230 14 230-240VAC (50/60Hz GMC-9M-10-480 14 480VAC (50/60Hz AC) GMD-9M-10-12 17 12VDC GMD-9M-10-24 17 24VDC 12 Amp, Screw Terminals GMC-12M-10-24 15 24VAC (50/60Hz AC) GMC-12M-10-120 15 120VAC (50/60Hz AC) GMC-12M-10-208 15 200-208VAC (50/60Hz GMC-12M-10-230 15 230-240VAC (50/60Hz GMC-12M-10-480 15 480VAC (50/60Hz AC) GMD-12M-10-12 19 12VDC GMD-12M-10-24 19 24VDC GTK-12M 17 0.1 16A Aux. Contacts Direct Mounting to Meta-Mec Mini Contactors UL508 compliant Screw terminals Differential current UL and CE certified RoHS compliant Built-in auxiliary contacts (1 N.0., 1 N.C.) Resistive Load (AC1) 1 N.O. 20A 1 N.O. 20A 1 N.O. 20A 1 N.O. 20A 1 N.O. 20A 1 N.O. 20A Formerly LG Industrial Systems UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 230V 460V 575V 0. (9.8A) 0. (9.8A) 0. (9.8A) 0. (9.8A) 1HP (16A) 1HP (16A) 1HP (8A) 1HP (8A) 1. (10A) 1. (10A) 2HP (12A) 2HP (12A) 1. (6A) 1. (6A) (9.6A) (9.6A) (9.6A) (9.6A) (4.8A) (4.8A) (7.6A) (7.6A) 7. (11A) 7. (11A) Mini Thermal Overload Relays Part Number Price Current Range GTK-12M-0.16A 17 0.1-0.16A GTK-12M-0.25A 17 0.16-0.25A GTK-12M-0.4A 17 0.25-0.4A GTK-12M-0.63A 17 0.4-0.63A GTK-12M-1.0A 17 0.63-1A GTK-12M-1.6A 17 1-1.6A GTK-12M-2.5A 17 1.6-2.5A GTK-12M-4A 17 2.5-4A GTK-12M-6A 17 4-6A GTK-12M-8A 17 5-8A GTK-12M-9A 17 6-9A GTK-12M-10A 17 7-10A GTK-12M-13A 17 9-13A GTK-12M-16A 17 12-16A (3.9A) (3.9A) (6.1A) (6.1A) 7. (9A) 7. (9A) Optional Overload Relay GTK-12M GTK-12M GTK-12M GTK-12M GTK-12M GTK-12M Applicable Contactor GMC-6M GMC-9M GMC-12M GMD-6M GMD-9M GMD-12M To Order Call 1.800.972.0436 or Visit factorymation.com

Mini Contactors & Overloads (cont d) 109 Formerly LG Industrial Systems Mini Series Accessories Part Number Price Description Auxiliary Contacts AU-1M-10 4 Side-mount, 1 N.O., GMC-6 to GMC-12 AU-1M-01 4 Side-mount, 1N.C., GMC-6 to GMC-12 AU-2M-02 6 Top-mount, 2 N.C., GMC-6 to GMC-12 AU-2M-11 6 Top-mount, 1 N.O. / 1 N.C., GMC-6 to GMC-12 AU-2M-20 6 Top-mount, 2 N.O., GMC-6 to GMC-12 AU-4M-40 7 Top-mount, 4 N.O., GMC-6 to GMC-12 AU-4M-22 7 Top-mount, 2 N.O. / 2 N.C., GMC-6 to GMC-12 AU-4M-04 7 Top-mount, 4 N.C., GMC-6 to GMC-12 Direct Adapters for Manual Motor Starter + Contactor DA-16HA 5 MMS-32H + GMC-xM (AC coil version) DA-16HD 5 MMS-32H + GMD-xM (DC coil version) Mechanical Interlocks and Reversing Kits for GMC-6 to GMC-12 AR-12M 4 Mechanical Interlock for Reversing Configuration AR-12MW 5 Mechanical Interlock and Reversing Wire Kit Contactor Plug-in Coil Surge Suppressors AS-12M-1 4 GMC-6 to GMC-12, 24-48VAC, Varistor AS-12M-2 4 GMC-6 to GMC-12, 60-127VAC, Varistor AS-12M-3 4 GMC-6 to GMC-12, 200-240VAC, Varistor AS-12M-4 4 GMD-6 to GMD-12, 12-24VDC, Varistor ON Delay and OFF Delay Timer Units AT-12M-1N 52 Timer Unit, ON Delay, 0.1-30s, 24 to 48V AC/DC AT-12M-1F 52 Timer Unit, OFF Delay, 0.1-30s, 24 to 48V AC/DC AT-12M-2N 52 Timer Unit, ON Delay, 0.1-30s, 100 to 220V AC/DC AT-12M-2F 52 Timer Unit, OFF Delay, 0.1-30s, 100 to 220V AC/DC Overload Separate Mount Units AZ-12MH 5 Separate Mount Unit for GTK12M Overloads Auxiliary Contacts AU-2M Mini Contactor and Overload Specifications Contactor Number of Poles Rated insulation voltage, Ui Short Circuit Max Current Mini Contactor Dimensions GMC-6M GMD-6M GMC-9M GMD-9M 3 pole 690V 5kA GMC-12M GMD-12M Breaking Capacity 60A 90A 120A Maximum Operations Per Hour (AC3) 1800 Mechanical Durability Electrical Durability Auxiliary Contacts (Standard) Thermal Magnetic Overload Rated Insulation Voltage, Ui 12 million operations 1 million operations 1 N.O. GTK-12M 690V Trip Class Class 10 Protection Type Auxiliary Contacts (Standard) Standards GMC, GMD, & GTK Standards Coil Current Consumption for Mini Contactors Part Number AC Coil Differential, Phase Loss, Over Current 1 N.O. / 1 N.C. UL508 File # 108780, cul, CE DC Coil GMC-6M GMC-9M GMC-12M GMD-6M GMD-9M GMD-12M Standard Voltages 50/60Hz/ 24-480V 12-24V Operating Voltage Limits Coil Consumption Pick-up 80-110% 80-110% Drop-out 30-40% 10-30% Inrush 32VA 32VA 32VA 3W 3W 3W Sealed 6VA 6VA 6VA 3W 3W 3W Thermal Dissipation Watts 2 2 2 3 3 3 Contactor A B C D E F G GMC-xM 1.77 (45mm) Dimensions in(mm) 2.51 (63.7mm) A 2.28 (58mm) 4.57 (116.1mm) B 1.77 (45mm) 6.52 (165.7mm) 3.92 (99.6mm) MOTOR CONTROLS www.factorymation.com/motorcontrols AU-1M C Reversing Kit Time Delay Unit D Contactor & Overload AR-12MW AT-12M E G Separate Mount Unit Direct Mount Adapter F AZ-12MH (Shown attached to GTK12M overload) DA-16HA (Direct Adapter connects Mini Contactor and Manual Motor Starter, MMS-32H) Contactor & Manual Motor Starter ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

110 Contactors & Overloads Formerly LG Industrial Systems www.factorymation.com/motorcontrols MOTOR CONTROLS E108780 DIN rail mountable (through 150A) UL508 Compliant 0. to 600HP Direct-Mounting Overload Relays RoHS Compliant Auxiliary Contacts Standard UL and CE Certified IEC 60947 Optional Accessories Include: Additional Auxiliary Contact Blocks Replacement Coils Reverse Wiring Kits and Interlocks Direct Wiring Adapters for MMS Coil Surge Suppression Remote Reset REMOVEABLE AUX CONTACTS 7.5 590A 40A Frame Size 0. 600HP Metasol Contactors (9-800A) 16 Part Number Price Coil Voltage 22 Amp Frame, Screw Clamp Terminals MC-9B-11-AC24 16 24VAC (50/60Hz) MC-9B-11-AC120 16 120VAC (50/60Hz) MC-9B-11-AC208 16 208VAC (60Hz) MC-9B-11-AC230 16 230VAC (50/60Hz) MC-9B-11-AC480 16 480VAC (60Hz) MC-9B-11-DC24 21 24VDC MC-12B-11-AC24 19 24VAC (50/60Hz) MC-12B-11-AC120 19 120VAC (50/60Hz) MC-12B-11-AC208 19 208VAC (60Hz) MC-12B-11-AC230 19 230VAC (50/60Hz) MC-12B-11-AC480 19 480VAC (60Hz) MC-12B-11-DC24 25 24VDC MC-18B-11-AC24 26 24VAC (50/60Hz) MC-18B-11-AC120 26 120VAC (50/60Hz) MC-18B-11-AC208 26 208VAC (60Hz) MC-18B-11-AC230 26 230VAC (50/60Hz) MC-18B-11-AC480 26 480VAC (60Hz) MC-18B-11-DC24 37 24VDC MC-22B-11-AC24 32 24VAC (50/60Hz) MC-22B-11-AC120 32 120VAC (50/60Hz) MC-22B-11-AC208 32 208VAC (60Hz) MC-22B-11-AC230 32 230VAC (50/60Hz) MC-22B-11-AC480 32 480VAC (60Hz) MC-22B-11-DC24 41 24VDC 40 Amp Frame, Screw Clamp Terminals MC-32A-22-AC24 38 24VAC (50/60Hz) MC-32A-22-AC120 38 120VAC (50/60Hz) MC-32A-22-AC208 38 208VAC (60Hz) MC-32A-22-AC230 38 230VAC (50/60Hz) MC-32A-22-AC480 38 480VAC (60Hz) MC-32A-22-DC24 50 24VDC MC-40A-22-AC24 48 24VAC (50/60Hz) MC-40A-22-AC120 48 120VAC (50/60Hz) MC-40A-22-AC208 48 208VAC (60Hz) MC-40A-22-AC230 48 230VAC (50/60Hz) MC-40A-22-AC480 48 480VAC (60Hz) MC-40A-22-DC24 59 24VDC 65 Amp Frame, Box Lug Terminals MC-50A-22-AC24 66 24VAC (50/60Hz) MC-50A-22-AC120 66 120VAC (50/60Hz) MC-50A-22-AC208 66 208VAC (60Hz) MC-50A-22-AC230 66 230VAC (50/60Hz) MC-50A-22-AC480 66 480VAC (60Hz) MC-50A-22-DC24 76 24VDC MC-65A-22-AC24 71 24VAC (50/60Hz) MC-65A-22-AC120 71 120VAC (50/60Hz) MC-65A-22-AC208 71 208VAC (60Hz) MC-65A-22-AC230 71 230VAC (50/60Hz) MC-65A-22-AC480 71 480VAC (60Hz) MC-65A-22-DC24 95 24VDC Resistive Aux. Load Contacts (AC1) 1 N.O. 1 N.C. 1 N.O. 1 N.C. 1 N.O. 1 N.C. 1 N.O. 1 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 25 25 40 40 50 60 70 100 UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 200V 230V 460V 575V 0. (9.8A) 0.7 (13.8A) 1HP (16A) 2HP (24A) 2HP (24A) (34A) (34A) (65A) 1. (10A) 2HP (12A) (17A) (17A) (28A) 7. (40A) 10HP (50A) 1 (85A) 2HP (7.5A) (10.6A) (16.7A) 7. (24.2A) 7. (24.2A) 1 (46.2A) 20HP (59.4A) 2 (74.8A) (9.6A) (15.2A) 7. (22A) 10HP (28A) 10HP (28A) 1 (54A) 2 (68A) 30HP (65A) (7.6A) 7. (11A) 10HP (14A) 1 (21A) 20HP (27A) 30HP (40A) 40HP (52A) 50HP (65A) 7. (9A) 10HP (11A) 1 (17A) 20HP (22A) 2 (27A) 30HP (41A) 50HP (52A) 60HP (65A) Optional Overload Relay MT-32 MT-32 MT-32 MT-32 MT-32 MT-32 MT-63 MT-63 REMOVEABLE AUX CONTACTS 65A Frame Size To Order Call 1.800.972.0436 or Visit factorymation.com

Contactors & Overloads (cont d) 111 REMOVEABLE AUX CONTACTS REMOVEABLE AUX CONTACTS 225A Frame Size 800A Frame Size 100A Frame Size 150A Frame Size Metasol Contactors (9-800A) Part Number Price Coil Voltage 100 Amp Frame, Box Lug Terminals MC-75A-22-AC24 81 24VAC (50/60Hz) MC-75A-22-AC120 81 120VAC (50/60Hz) MC-75A-22-AC208 81 208VAC (60Hz) MC-75A-22-AC230 81 230VAC (50/60Hz) MC-75A-22-AC480 81 480VAC (60Hz) MC-75A-22-DC24 113 24VDC MC-85A-22-AC24 88 24VAC (50/60Hz) MC-85A-22-AC120 88 120VAC (50/60Hz) MC-85A-22-AC208 88 208VAC (60Hz) MC-85A-22-AC230 88 230VAC (50/60Hz) MC-85A-22-AC480 88 480VAC (60Hz) MC-85A-22-DC24 134 24VDC MC-100A-22-AC24 140 24VAC (50/60Hz) MC-100A-22-AC120 140 120VAC (50/60Hz) MC-100A-22-AC208 140 208VAC (60Hz) MC-100A-22-AC230 140 230VAC (50/60Hz) MC-100A-22-AC480 140 480VAC (60Hz) MC-100A-22-DC24 165 24VDC 150 Amp Frame, Box Lug Terminals MC-130A-22-AC24 201 24VAC (50/60Hz) MC-130A-22-AC120 201 120VAC (50/60Hz) MC-130A-22-AC230 201 230VAC (50/60Hz) MC-130A-22-AC480 201 VAC (50/60Hz) MC-130A-22-DC24 235 24VDC MC-150A-22-AC24 240 24VAC (50/60Hz) MC-150A-22-AC120 240 120VAC (50/60Hz) MC-150A-22-AC230 240 230VAC (50/60Hz) MC-150A-22-AC480 240 VAC (50/60Hz) MC-150A-22-DC24 290 24VDC 225 Amp Frame, Screw Terminals MC-185A-22-AC/DC24 324 24VAC/24VDC MC-185A-22-AC/DC100-200 324 100-240VAC/100-220VDC MC-185A-22-AC 324 440-575VAC MC-225A-22-AC/DC24 392 24VAC/24VDC MC-225A-22-AC/DC100-200 392 100-240VAC/100-220VDC MC-225A-22-AC 392 440-575VAC 400 Amp Frame, Screw Terminals Resistive Aux. Load Contacts (AC1) 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. MC-265A-22-AC/DC100-200 527 100-240VAC/100-220VDC 2 N.O. MC-265A-22-AC 527 440-575VAC 2 N.C. MC-330A-22-AC/DC100-200 535 100-240VAC/100-220VDC 2 N.O. MC-330A-22-AC 535 440-575VAC 2 N.C. MC-400A-22-AC/DC100-200 604 100-240VAC/100-220VDC 2 N.O. MC-400A-22-AC 604 440-575VAC 2 N.C. 800 Amp Frame, Screw Terminals MC-A-22-AC/DC100 1,232 100-127VAC/100-110VDC MC-A-22-AC/DC200 1,232 200-240VAC/200-220VDC MC-A-22-AC 1,232 440-575VAC MC-630A-22-AC/DC100 1,301 100-127VAC/100-110VDC MC-630A-22-AC/DC200 1,301 200-240VAC/200-220VDC MC-630A-22-AC 1,301 440-575VAC MC-800A-22-AC/DC100 1,442 100-127VAC/100-110VDC MC-800A-22-AC/DC200 1,442 200-240VAC/200-220VDC MC-800A-22-AC 1,442 440-575VAC 2 N.O. 2 N.C. 2 N.O. 2 N.C. 2 N.O. 2 N.C. 110 135 160 160 210 230 275 UL HP Ratings (AC3 Motor Load) Single Phase Three Phase 115V 230V 200V 230V 460V 575V (56A) 7. (80A) 10HP (100A) 10HP (100A) 1 (135A) 1 (135A) 1 (135A) 1 (68A) 1 (68A) 20HP (56A) 20HP (88A) 2 (110A) 30HP (136A) 40HP (176A) 300 N/A N/A 350 N/A N/A 450 N/A N/A 580 N/A N/A 660 N/A N/A 900 N/A N/A Formerly LG Industrial Systems 2 (78A) 30HP (88A) 30HP (88A) 40HP (120A) 40HP (120A) 60HP (177A) 60HP (177A) 7 (221A) 100HP (285A) 12 (359A) 150HP (414A) 200HP (552A) 200HP (552A) 30HP (80A) 40HP (104A) 40HP (104A) 40HP (104A) 50HP (130A) 60HP (154A) 7 (192A) 100HP (248A) 12 (312A) 150HP (360A) 200HP (480A) 250HP (602A) 50HP (65A) 60HP (77A) 7 (96A) 7 (96A) 100HP (124A) 12 (156A) 150HP (180A) 200HP (240A) 250HP (302A) 300HP (361A) 400HP (477A) HP (590A) 60HP (62A) 7 (77A) 7 (77A) 7 (77A) 7 (77A) 12 (125A) 150HP (144A) 200HP (192A) 250HP (242A) 300HP (289A) 400HP (382A) HP (472A) Optional Overload Relay MT-95 MT-95 MT-95 MT-150 MT-150 MT-225 MT-225 MT-400 MT-400 MT-400 MT-800 MT-800 300HP 600HP 600HP MT-800 MOTOR CONTROLS www.factorymation.com/motorcontrols ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

112 Thermal Overload Relays Formerly LG Industrial Systems www.factorymation.com/motorcontrols MOTOR CONTROLS MT-32 Thermal Overload Relay Features Dial Trip Setting Dial Cover Finger Safe Terminals 27 0.1 800A E108780 Trip ranges from 0.1A to 800A Direct mounting to Metasol contactors Separate mount adapter available (through MT-150) Optional lug terminals for screw terminal versions, ordered separately Ambient Compensated 23 to 104 F (-5 to 40 C) Manual / Automatic Reset Differential Current / Phase Loss Protection Auxiliary contacts Included Trip Class 10 UL and CE Certified IEC 60947 Identification Label Stop/Test Button Trip Indicator Reset Button Selector Aux Contacts Part Number Price Aux Contacts Current Range MT-32S-0.16A 27 1 N.O. / 1N.C. 0.1-0.16A MT-32S-0.25A 27 1 N.O. / 1N.C 0.16-0.25A MT-32S-0.4A 27 1 N.O. / 1N.C. 0.25-0.4A MT-32S-0.63A 27 1 N.O. / 1N.C 0.4-0.63A MT-32S-1A 27 1 N.O. / 1N.C. 0.63-1A MT-32S-1.6A 27 1 N.O. / 1N.C 1-1.6A MT-32S-2.5A 27 1 N.O. / 1N.C. 1.6-2.5A MT-32S-4A 27 1 N.O. / 1N.C 2.5-4A MT-32S-6A 27 1 N.O. / 1N.C. 4-6A MT-32S-8A 27 1 N.O. / 1N.C 5-8A MT-32S-9A 27 1 N.O. / 1N.C. 6-9A MT-32S-10A 27 1 N.O. / 1N.C 7-10A MT-32S-13A 27 1 N.O. / 1N.C. 9-13A MT-32S-18A 27 1 N.O. / 1N.C. 12-18A MT-32S-22A 27 1 N.O. / 1N.C 16-22A MT-32S-25A 27 1 N.O. / 1N.C. 18-25A MT-32S-32A 35 1 N.O. / 1N.C 22-32A MT-32S-40A 35 1 N.O. / 1N.C 28-40A MT-63L-36A 48 1 N.O. / 1N.C. 24-36A MT-63L-40A 48 1 N.O. / 1N.C 28-40A MT-63L-50A 48 1 N.O. / 1N.C. 34-50A MT-63L-65A 48 1 N.O. / 1N.C. 45-65A MT-95L-65A 62 1 N.O. / 1N.C. 45-65A MT-95L-75A 62 1 N.O. / 1N.C 54-75A MT-95L-85A 62 1 N.O. / 1N.C. 63-85A MT-95L-95A 62 1 N.O. / 1N.C 70-95A MT-95L-100A 75 1 N.O. / 1N.C 80-100A MT-150-105A 135 1 N.O. / 1N.C 80-105A MT-150-130A 135 1 N.O. / 1N.C 95-130A MT-150-150A 135 1 N.O. / 1N.C. 110-150A MT-225-160A 165 1 N.O. / 1N.C 100-160A MT-225-185A 165 1 N.O. / 1N.C. 120-185A MT-225-240A 165 1 N.O. / 1N.C 160-240A MT-400-240A 240 1 N.O. / 1N.C. 160-240A MT-400-330A 240 1 N.O. / 1N.C. 200-330A MT-400-400A 240 1 N.O. / 1N.C 260-400A MT-800-400A 528 1 N.O. / 1N.C 260-400A MT-800-600A 528 1 N.O. / 1N.C 400-630A MT-800-800A 528 1 N.O. / 1N.C. 520-800A Applicable Contactor MC-9B MC-12B MC-18B MC-22B MC-32A MC-40A MC-50A MC-65A MC-75A MC-85A MC-100A MC-130A MC-150A MC-185A MC-225A MC-265A MC-330A MC-400A MC-A MC-630A MC-800A Direct Mounting MT-63 MT-225 MT-95 MT-400 MT-800 MC-40 & MT-32 MC-400 & MT-400 MT-150 To Order Call 1.800.972.0436 or Visit factorymation.com

Thermal Overload Relays (cont d) 113 Formerly LG Industrial Systems Contactor & Overload Accessories Auxiliary Contact UA-1-11 MMS Direct Adapter DA-95A MMS + Contactor Mounting Unit MU-45 Mechanical Interlock with Aux Contact UR-02 Part Number Price Description Auxiliary Contacts UA-1-11 8 Side-mount, 1 N.O. / 1N.C., MC-9 to MC-150 UA-2-11 6 Top-mount, 1 N.O. / 1 N.C., MC-9 to MC-150 UA-4-22 9 Top-mount, 2 N.O. / 2 N.C., MC-9 to MC-150 UA-4-40 9 Top-mount, 4 N.O., MC-9 to MC-150 UA-4-04 9 Top-mount, 4 N.C., MC-9 to MC-150 AU-100-11 8 Side-mount, 1 N.O. / 1 N.C., MC-185 to MC-800 AU-100E-11 9 Side-mount, 1 N.O. / 1 N.C., MC-185 to MC-800 MMS + Contactor Direct Adapters DA-22HA 8 MMS-32H + MC-9B-22B AC DA-22HD 8 MMS-32H + MC-9B-22B DC DA-32HA 9 MMS-32H + MC-32A-40A AC DA-32HD 9 MMS-32H + MC-32A-40A DC DA-63A 9 MMS-63H + MC-50A to MC-65A AC DA-63D 9 MMS-63H + MC-50A to MC-65A DC DA-95A 10 MMS-100H + MC-75A to MC-100A AC DA-95D 10 MMS-100H + MC-75A to MC-100A DC MMS + Contactor Mounting Unit / Base Plate MU-45 8 MMS-32H + MC-9 to MC-40 (45mm) MU-55 14 MMS-63H + MC-50 to MC-65 (55mm) MU-70 16 MMS100H + MC-75 to MC-100 (70mm) Contactor Coil Surge Suppressors US-1 9 MC-9 to MC-150, AC24-48V, Varistor + RC US-2 9 MC-9 to MC-150, AC100-125V, Varistor + RC US-3 9 MC-9 to MC-150, AC200-240V, Varistor + RC US-4 9 MC-9 to MC-150, DC24-48V, Varistor + RC US-5 9 MC-9 to MC-150, DC100-125V, Varistor + RC US-6 9 MC-9 to MC-150, DC200-220V, Varistor + RC US-11 7 MC-9 to MC-150, ACDC24-48V, Varistor US-12 7 MC-9 to MC-150, ACDC100-125V, Varistor US-13 7 MC-9 to MC-150, ACDC200-240V, Varistor US-14 7 MC-9 to MC-150, ACDC380-440V, Varistor US-22 7 MC-9 to MC-150, AC100-125V, RC Overload Remote Reset Kits UM-4R 44 400mm cable, MT-12 to MT-95 UM-5R 48 mm cable, MT-12 to MT-95 UM-6R 52 600mm cable, MT-12 to MT-95 Overload Separate Mount Units UZ-32S 6 for MT-32S Overload UZ-63L 8 for MT-63L Overload UZ-95L 10 for MT-95L Overload Part Number Price Description Terminal Covers AP-220 6 Terminal cover (2 pcs), MC-185A to MC-225A (input and output) AP-400 8 Terminal cover (2 pcs), MC-265A to MC-400A (input and output) AP-800 13 Terminal cover (2 pcs), MC-A to MC-800A (input and output) APT-220 6 Terminal cover assembly, MT-225 APT-400 6 Terminal cover assembly, MT-400 APT-600 8 Terminal cover assembly, MT-800 Reversing Kits UW-22 13 Reversing Wire Kit for MC-9 to MC-22 UW-32 13 Reversing Wire Kit for MC-32 to MC-40 UW-63 19 Reversing Wire Kit for MC-50 to MC-65 UW-95 34 Reversing Wire Kit for MC-75 to MC-100 Mechanical Interlocks UR-02 12 Mechanical Interlock, 2 N.C., MC-9 to MC-150 AR-180 28 Mechanical Interlock, MC-180A to MC-400A AR-600 333 Mechanical Interlock, MC-A to MC-800A Reversing Base Plates RBP-180/220 42 Reversing Base Plate Interlock, MC-185A to MC-225A RBP-300/400 56 Reversing Base Plate Interlock, MC-265A to MC-400A Insulation Barriers AI-180 1 Insulation Barrier (4pcs.), MC-185A to MC-400A AI-600 2 Insulation Barrier (4pcs.), MC-A to MC-800A Lug Terminals AJ-220 13 Lug Terminals for MC-185A to MC-225A (3 pcs) AJ-400 25 Lug Terminals for MC-265A to MC-400A (3 pcs) AJ-800 45 Lug Terminals for MC-A to MC-800A (3 pcs) Terminal Cover AP-220 Installing Auxiliary Contacts UA-1 UA-2,4 Lug Terminals AJ-220 MOTOR CONTROLS www.factorymation.com/motorcontrols UZ-150S 13 for MT-150 Overload Surge Suppressor US-2 Remote Reset Cable UM-4R O/L Separate Mount UZ-32S (Shown with O/L) To install side-mounting aux contacts remove the indicated part in the circle first. Then fit each part as shown. To separate push forward and pull. To install top-mounting aux contacts position on top of contactor and push down. To separate, pull the lever of the contact block and push upward. ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

114 Formerly LG Industrial Systems www.factorymation.com/motorcontrols MOTOR CONTROLS Metasol Contactor and Overload Specifications Contactor MC-9B MC-75A MC-A MC-32A MC-50A MC-130A MC-185A MC-265A MC-12B MC-22B MC-85L MC-40A MC-65A MC-150A MC-225A MC-330A MC-400A MC-630A MC-18B MC-100L MC-800A Number of Poles 3 3 pole Rated Operational Voltage, Ue 690V Rated Insulation Voltage, Ui 690V 1000V 1000V 1000V Rated Frequency 60Hz Rated Impulse Withstand Voltage, Uimp 6kV 8kV 8kV 8kV Maximum Operations Per Hour (AC3) 1800 1800 1800 1800 1200 Mechanical Durability (Million Operations) 15 12 12 12 5 5 5 2.5 2.5 Electrical Durability (Million Operations) 2.5 2 2 2 1 1 1 0.5 0.5 Auxiliary Contacts (Standard) 1 N.O. / 1 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. 2 N.O. / 2 N.C. Thermal Magnetic Overload MT-12 MT-32 MT-32 MT-63 MT-95 MT-150 MT-225 MT-400 MT-800 Rated Operational Voltage, Ue 690V Rated Insulation Voltage, Ui 690V Rated Impulse Withstand Voltage, Uimp 6kV Trip Class 10 Setting Range 0.1-18A 0.1-40A 0.1-40A 4-65A 7-100A 34-150A 65-240A 85-400A 200-800A Standards UL File # E108780 / E206826 Coil Current Consumption Part Number AC Coil Control Voltage Voltage Limit Coil Consumption @ 20 C (220V, 60Hz) DC Coil MC-9B to MC-22B MC-32A MC-40A MC-50A MC-65A MC-75A MC-85A MC-100A MC-130A MC-150A 50Hz 24, 120, 230 24, 120, 230, 60Hz 24, 120, 208, 230, 480 MC-185A MC-225A 24, 100-240, 440-575 MC-265A MC-400A 100-240, 380-450, 440-575 MC-A MC-800A In240, 440-575 Operational 85-110% 85-110% 85-110% 85-110% 85-110% 85-110% 85-110% 85-110% Drop-out 30-60% 30-60% 30-60% 30-60% 30-60% 30-60% 30-60% 30-60% Inrush (VA) 56 50 104 216 104 380 571 1,000 Sealed (VA) 6 9 10 16 21 11.6 14 29 Control Voltage DC 12, 24 12, 24 12, 24 12, 24 N/A N/A N/A N/A Voltage Limit Current Consumption Dimensions in(mm) D A1 A2 * Mounting plate dimension Operational 70-110% 70-110% 70-110% 70-110% N/A N/A N/A N/A Drop-out 10-30% 10-30% 10-30% 10-30% N/A N/A N/A N/A Inrush (W) 9 7 9 18 N/A N/A N/A N/A Sealed (W) 9 7 9 18 N/A N/A N/A N/A B C Metasol Contactor and Overload Dimensions Contactor A1 A2 B C D AC Contactors MC-9 AC MC-18 AC - 1.77 (45mm) 3.44 (87.4mm) 2.89 (73.5mm) 5.11 (129.9mm) MC-22 AC - 1.77 (45mm) 3.39 (86mm) 2.89 (73.5mm) 5.11 (129.9mm) MC-32 AC MC-40 AC 2.72 (69mm) 1.77 (45mm) 3.54 (90mm) 3.27 (83mm) 5.49 (139.4mm) MC-50 AC MC-65 AC 3.11 (79mm) 2.17 (55mm) 4.69 (119mm) 4.17 (106mm) 6.45 (163.8mm) MC-75 AC MC-100 AC 3.70 (94mm) 2.76 (70mm) 5.35 (135.8mm) 5.51 (140mm) 8.32 (211.4mm) MC-130 AC MC-150 AC 4.69"(119mm) 3.74 (95mm*) 5.13 (130.3mm) 6.22 (158mm) 9.30 (236.2mm) MC-185 AC/DC MC-225 AC/DC 6.38 (162mm*) 5.43 (138mm) 7.29"(185.1mm) 7.99 (203mm) 12.07 (306.5mm*) MC-265 AC/DC MC-400 AC/DC 7.36 (187mm*) 6.42 (163mm) 8.05 (204.4mm) 9.57 (243mm) 14.96 (380mm*) MC- AC/DC MC-800 AC/DC 14.17 (360mm*) 11.22(285mm) 9.66 (245.3mm) 12.28 (312mm) 20.87 (530mm*) DC Contactors MC-9 DC MC-18 DC - 1.77 (45mm) 4.63 (117.7mm) 2.89 (73.5mm) 5.11 (129.9mm) MC-22 DC - 1.77 (45mm) 4.63 (117.7mm) 2.89 (73.5mm) 5.11 (129.9mm) MC-32 DC MC-40 DC 2.72 (69mm) 1.77 (45mm) 4.73 (120.1mm) 3.27 (83mm) 5.49 (139.4mm) MC-50 DC MC-65 DC 3.11 (79mm) 2.17 (55mm) 5.87 (149.2mm) 4.17 (106mm) 6.45 (163.8mm) MC-75 DC MC-100 DC 3.70 (94mm) 2.76 (70mm) 6.84 (173.8mm) 5.51 (140mm) 8.32 (211.4mm) MC-130 DC MC-150 DC - 3.74 (95mm*) 5.13 (130.3mm) 6.22 (158mm) 9.30 (236.2mm) Optional Auxiliary Contact Specifications Part Number UA-1-11 UA-2-11 UA-2-20 UA-4-22 UA-4-40 AU-100 AU-100E Rated Thermal Current (Ith) AC: 10A AC: 16A AC: 1A AC-15, A600 DC-13, P300 Mechanical Endurance Conductor Size 120V: 6A, 240V: 3A, 380V: 1.9A 480V: 1.5A, V: 1.4A, 600V: 1.2A 125V: 1.1A, 250V:.055A, 400V: 0.31A, V: 0.27A, 600V: 0.2A,000 operations 18AWG - 10AWG AC 24V 0.1A AC 50V 0.01A DC 24V 0.1A DC 50V 0.01A To Order Call 1.800.972.0436 or Visit factorymation.com

INDUSTRIAL MOTOR CONTROL PANELS 115 CERTIFIED PANEL BUILDER FactoryMation Panel Shop Advantages The FactoryMation Panel Shop can design and fabricate an extensive variety of control panels ranging from small motor starter panels to advanced motor control centers. Our engineers can assist in the development of designs based on customer requirements and/or customer supplied drawings. In-stock components mean even custom panels are completed with industry leading build times. Expert design and component selection Thousands of projects completed per year In-stock components Detailed schematic drawings and component/wire labeling for ease of maintenance and troubleshooting CNC precision cut-outs completed in-house for fast assembly and quick turn-around Quality inspection of each control panel prior to shipment Prompt delivery most standard control panels are assembled and shipped within 3 business days Free technical support and one year parts warranty MOTOR CONTROLS SELECTING A MOTOR STARTER Follow this step-by-step guide to select your custom motor starter: (1) Non-reversing or Reversing Non-reversing motor starters have a single contactor and are designed to run the motor in one direction only. Reversing motor starters use two mechanically interlocked contactors. The use of two contactors makes it possible to run the motor in two directions, forward or reverse, and the interlock prevents energizing both contactors at the same time. (2) Horsepower and FLA Ratings Check your motor nameplate to identify your motor s horsepower and full-load amp (FLA) ratings. Be sure the FLA rating of the motor does not exceed the FLA rating of the motor starter. The thermal overload device should be set to match the motor nameplate amps, not to exceed the FLA rating of the motor starter. If you have questions regarding selection of the motor starter that best fits your application, contact FactoryMation Technical Support. (3) Circuit Protection All of our combination motor starters have a through-the-door disconnect handle with safety lock-out provisions. (4) Input Voltage Select the input voltage of the motor starter. The input voltage should match the voltage used to power the motor. (5) Enclosure Rating Several enclosure options are available to closely match the requirements of your application. The following UL Type environmental ratings are available: ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 UL Type 1 - Indoor use primarily to provide a degree of protection against limited amounts of falling dirt. UL Type 12 - Indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping non-corrosive liquids. UL Type 3R - Outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation. UL Type 4 - Indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water and damage from external ice formation. UL Type 4X - Indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose-directed water, and damage from external ice formation. (6) Motor Starter Options Control Transformer Select a control transformer when it is desirable to reduce your control voltage for operator devices, pilot lights, and remote control components. Transformer primaries are wired for the same voltage as the motor starter input power. Transformers are available with a 120VAC secondary. Operators Optional operator devices can be selected to offer control from the front panel of the LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS motor starter. Operator device control voltage will be equivalent to the input voltage of the starter or the secondary voltage of the optional control transformer. If operators are excluded, the contactor coil can be specified to allow for remote operation of the motor starter. Operator options include: Non-Reversing - Start/Stop Pushbuttons - Hand-Off-Auto Selector Switch Reversing - Forward-Stop-Reverse Pushbuttons - Forward-Off-Reverse Selector Switch No Operators, remote control desired - No operators, 24VAC/60Hz contactor coil - No operators, 120VAC/60Hz contactor coil - No operators, 208VAC/60Hz contactor coil - No operators, 230VAC/60Hz contactor coil - No operators, 480VAC/60Hz contactor coil Pilot Lights Non-Reversing - Pilot Light, ON indication, RED color Reversing - Pilot Lights, 1-FWD and 1-REV indicator, RED color www.factorymation.com/motorcontrols

116 PREDESIGNED MOTOR CONTROL PANELS www.factorymation.com/motorcontrols MOTOR CONTROLS Standard motor control panels have predesigned layouts and prebuilt chassis systems. All components used to complete the panel assemblies are stocked in-house. Final assembly is completed in days, not weeks! Pushbutton Stations Combination Motor Starters (1/2-200 hp) Enclosed DOL Motor Starters (1/6-75 hp) MODIFIED/CUSTOM MOTOR CONTROL PANELS FactoryMation is capable of providing modifications to standard control panel designs as well as complete custom design/build control panels. A vast selection of industrial enclosures and controls are in-stock allowing for industry-leading build and delivery times even on custom control panels! Variable Speed AC Drive Panels Pump Controllers Reduced Voltage Starters Bypass Panels Operator Consoles and Panels Enclosed Contactors Fused and Non-Fused Disconnect Switches Circuit Breaker Disconnect Switches Junction/Terminal Boxes SHIPS IN 3 DAYS!* Combination Soft Starter Panels (5-1200 hp) *Most standard models can ship within three business days. VIEW IN THE FOLLOWING SECTION! GET A QUOTE RIGHT NOW! PHONE 1-800-972-0436 EMAIL SUPPORT@FACTORYMATION.COM To Order Call 1.800.972.0436 or Visit factorymation.com

Economy Enclosed DOL Motor Starters Full Voltage Magnetic Motor Starter 117 Dimensional information is available on the last page of this section. Note: Most standard configurations are in stock for same day shipping. 79 TYPE 4X PROTECTION UL Type 4X polymeric enclosure with standard size knockouts START/STOP models pre-wired for 3-wire control with through the cover overload RESET Class 10 overload relays - Class 10 direct heated bimetallic elements Adjustable trip current Ambient temperature compensation Phase-loss protection Selectable manual or automatic reset Electrically isolated N.O./N.C. auxiliary contacts UL508 Listed Assembly Build Your Part Number: Single-Phase Three-Phase Economy Direct-On-Line Motor Starter Non-Reversing Horsepower Motor Voltage EDOLPS - xxxhp - xxxv - N4P - xxxx - xxxx EDOLP - xxxhp - xxxv - N4P - xxxx - xxxx UL Type 4X, Plastic Control Voltage Operator Devices Single-phase Max. UL Ratings Part Number -RSET Operator Devices Reset Only Start/Stop Starter FLA 1 Current Trip Range 2 DIM EDOLPS- HP -RSET -STSR 120V 1/4 6.3 4.0 6.3A 0P2HP-120V-N4P EP1 79 86 1/3 8.0 5.6 8.0A 0P-120V-N4P EP1 79 86 1/2 10 7.0 10A 0P-120V-N4P EP1 81 89 1/2 12.5 8 12.5A OP5HH-120V-N4P EP1 81 89 3/4 15 10 15A 0P7HP-120V-N4P EP1 88 96 1 17 11 17 001HP-120V-N4P EP1 90 98 1-1/2 23 15 23A 1P-120V-N4P EP1 90 98 2 24 22 32A* O02HP-120V-N4P EP1 90 98 5 40 25 40A 00-120V-N4P EP3 188 205 230V 1/6 2.8 1.8 2.8A 0P1HP-230V-N4P EP1 79 86 1/3 4.0 2.8 4.0A 0P-230V-N4P EP1 79 86 1/2 6.3 4.0 6.3A 0P-230V-N4P EP1 79 86 1 8.0 5.6 8.0A 001HP-230V-N4P EP1 79 86 1-1/2 10 7 10A 1P-230V-N4P EP1 79 86 2 12.5 8.0 12.5A O02HP-230V-N4P EP1 88 96 2 15 10 15 002HH-230V-N4P EP1 88 96 3 17 11 17A O0-230V-N4P EP1 88 96 3 23 15 23 003HH-230V-N4P EP1 90 98 5 28 22 32A* 00-230V-N4P EP1 90 98 7-1/2 40 25 40A 007HP-230V-N4P EP2 135 147 -STSR MOTOR CONTROLS www.factorymation.com/motorcontrols Control Voltage Options Control/Coil Voltage -LINE 0 Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage -X240 0 Externally supplied 208-240VAC Control/Coil Voltage -X460 0 Externally supplied 460VAC Control/Coil Voltage Note 1: The actual FLA motor amps may vary from the HP values listed. Motor FLA found on the nameplate must be less than or equal to Starter FLA for proper motor protection. Motor FLA Starter FLA Note 2: Adjustable Overload range exceeds Starter FLA rating. Do not adjust overload setting to exceed starter FLA rating. ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

118 Economy Enclosed DOL Motor Starters (cont d) Full Voltage Magnetic Motor Starter www.factorymation.com/motorcontrols MOTOR CONTROLS Dimensional information is available on the last page of this section. Build Your Part Number: Single-Phase Three-Phase Economy Direct-On-Line Motor Starter Non-Reversing Horsepower Motor Voltage EDOLPS - xxxhp - xxxv - N4P - xxxx - xxxx EDOLP - xxxhp - xxxv - N4P - xxxx - xxxx UL Type 4X, Plastic Control Voltage Operator Devices Control Voltage Options Control/Coil Voltage -LINE 0 Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage -X240 0 Externally supplied 208-240VAC Control/Coil Voltage -X460 0 Externally supplied 460VAC Control/Coil Voltage 79 TYPE 4X PROTECTION UL Type 4X polymeric enclosure with standard size knockouts START/STOP models pre-wired for 3-wire control with through the cover overload RESET Class 10 overload relays - Class 10 direct heated bimetallic elements Adjustable trip current Ambient temperature compensation Phase-loss protection Selectable manual or automatic reset Electrically isolated N.O./N.C. auxiliary contacts UL508 Listed Assembly Note: Most standard configurations are in stock for same day shipping. Note 1: The actual FLA motor amps may vary from the HP values listed. Motor FLA found on the nameplate must be less than or equal to Starter FLA for proper motor protection. Motor FLA Starter FLA Note 2: Adjustable Overload range exceeds Starter FLA rating. Do not adjust overload setting to exceed starter FLA rating. Three-phase Max. UL Ratings Part Number -RSET -STSR Operator Devices Reset Only Start/Stop Starter Current FLA 1 Trip Range 2 DIM EDOLP- HP -RSET -STSR 208V 1/2 2.8 1.8 2.8A 0P-208V-N4P EP1 79 86 3/4 4.0 2.8 4.0A 0P7HP-208V-N4P EP1 79 86 1 6.3 4.0 6.3A 001HP-208V-N4P EP1 79 86 2 8.0 5.6 8.0A 002HP-208V-N4P EP1 79 86 2 10 7 10A 002HH-208V-N4P EP1 79 86 3 12.5 8.0 12.5A O0-208V-N4P EP1 88 96 3 15 10 15A 003HH-208V-N4P EP1 88 96 5 17 11 17A O0-208V-N4P EP1 88 96 5 23 15 23A 005HH-208V-N4P EP1 90 98 7-1/2 25 22 32A* O07HP-208V-N4P EP1 90 98 10 40 25 40A 010HP-208V-N4P EP3 188 205 15 50 32 50A 01-208V-N4P EP3 197 215 15 57 40 57A 015HH-208V-N4P EP3 197 215 20 62.1 50 63A* 020HP-208V-N4P EP3 197 215 25 80 63 80A 02-208V-N4P EP4 330 361 30 92 75 97A* 030HP-208V-N4P EP4 330 361 230V 1/2 2.8 1.8 2.8A 0P-230V-N4P EP1 79 86 3/4 4.0 2.8 4.0A 0P7HP-230V-N4P EP1 79 86 1 6.3 4.0 6.3A 001HP-230V-N4P EP1 79 86 2 8.0 5.6 8.0A 002HP-230V-N4P EP1 79 86 3 10 7 10A O0-230V-N4P EP1 88 96 3 12.5 8.0 12.5A 003HH-230V-N4P EP1 88 96 5 15 10 15A O0-230V-N4P EP1 88 96 5 17 11 17A 005HH-230V-N4P EP1 90 98 7-1/2 22 15 23A* O07HP-230V-N4P EP1 90 98 10 40 25 40A 010HP-230V-N4P EP2 135 147 15 50 32 50A 01-230V-N4P EP3 197 215 20 57 40 57A 020HP-230V-N4P EP3 199 217 20 63 50 63A 020HH-230V-N4P EP3 199 217 25 68 57 70A* 02-230V-N4P EP3 202 221 30 80 63 80A 030HP-230V-N4P EP4 319 349 30 97 75 97A 030HH-230V-N4P EP4 330 361 40 104 90 112A* 040HP-230V-N4P EP4 330 361 460V 1/2 1.2 0.8 1.2A 0P-460V-N4P EP1 79 86 3/4 1.8 1.2 1.8A 0P7HP-460V-N4P EP1 79 86 1 2.8 1.8 2.8A 001HP-460V-N4P EP1 79 86 2 4.0 2.8 4.0A 002HP-460V-N4P EP1 79 86 3 6.3 4.0 6.3A O0-460V-N4P EP1 79 86 5 8.0 5.6 8.0A O0-460V-N4P EP1 81 89 5 10 7 10A 005HH-460V-N4P EP1 81 89 7-1/2 12.5 8.0 12.5A O07HP-460V-N4P EP1 88 96 10 15 10 15A 010HP-460V-N4P EP1 90 98 10 17 11 17A 010HH-460V-N4P EP1 90 98 15 21 15 23A* 01-460V-N4P EP1 90 98 20 40 25 40A 020HP-460V-N4P EP2 135 147 30 50 32 50A 030HP-460V-N4P EP3 188 205 40 57 40 57A 040HP-460V-N4P EP3 197 215 40 63 50 63A 040HH-460V-N4P EP3 197 215 50 65 57 70A* 050HP-460V-N4P EP3 200 218 60 80 63 80A* 060HP-460V-N4P EP4 319 349 75 96 75 97A* 07-460V-N4P EP4 330 361 To Order Call 1.800.972.0436 or Visit factorymation.com

Economy Enclosed DOL Motor Starters (cont d) UL Type 1, Non-reversing Product shown in picture includes optional items. Dimensional information is available on the last page of this section. DOL Motor Starters include contactor and thermal overload Single-phase 120V and 230V input voltage models available, 1/ to 10HP Three-phase 208V, 230V, and 460V input voltage models available, 1/2HP to 50HP UL Type 1 listed enclosure Mechanical reset standard All components UL/CUL certified *Most standard models can ship within three business days. Build Your Part Number: Single-Phase Three-Phase Economy Direct-On-Line Motor Starter Non-Reversing Horsepower UL Type Rating Control Voltage Operator Devices Motor Voltage EDOLNRS - xxxhp - xxxv - N01 - xxxx - xxxx EDOLNR - xxxhp - xxxv - N01 - xxxx - xxxx Options (select one of each) Control/Coil Voltage -LINE 0 Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage -X208 0 Externally supplied 208VAC Control/Coil Voltage -X230 0 Externally supplied 230VAC Control/Coil Voltage -X460 0 Externally supplied 460VAC Control/Coil Voltage Operator Devices -RSET 0 Reset Pushbutton Only -SSTR 25 Start/Stop and Reset Pushbuttons -HOAP 25 -STHR 50 110 UP TO 50HP SHIPS IN 3 DAYS!* Hand-Off-Auto Selector Switch and Reset Pushbutton Start/Stop, Hand-Off-Auto Selector Switch, and Reset Pushbutton Single-phase 120V 1/3 7.2 5.6 8.0A 0P-120V ED1 110 1/2 9.8 7.0 10A 0P-120V ED1 110 3/4 13.8 10 15A 0P7HP-120V ED1 112 1 16 11 17A O01HP-120V ED1 117 1-1/2 20 15 23A 1P-120V ED1 119 2 24 22 32A O02HP-120V ED1 137 3 34 25 40A O0-120V ED2 137 230V 1/2 4.9 4.0 6.3A 0P-230V ED1 110 3/4 6.9 5.6 8.0A 0P7HP-230V ED1 110 1 8 5.6 8.0A O01HP-230V ED1 110 1-1/2 10 8.0 12.5A 1P-230V ED1 112 2 12 10 15A O02HP-230V ED1 112 3 17 11 17A O0-230V ED1 117 5 28 22 32A O0-230V ED1 137 7-1/2 40 32 50A O07HP-230V ED2 324 10 50 32 50A 010HP-230V ED2 334 Three-phase Part Number UL Type 1 Max. UL Ratings Current -N01 Trip Range EDOLNRS- HP FLA DIM Price Part Number UL Type 1 Max. UL Ratings Current -N01 Trip Range EDOLNR- HP FLA DIM Price 208V 1/2 2.4 1.8 2.8A 0P-208V ED1 110 1 4.6 4.0 6.3A 001HP-208V ED1 110 1-1/2 6.6 5.6 8.0A 1P-208V ED1 110 2 7.5 5.6 8.0A 002HP-208V ED1 110 3 10.6 8.0 12.5A O0-208V ED1 110 5 16.7 11 17A O0-208V ED1 117 7-1/2 24.2 22 32A O07HP-208V ED1 119 10 30.8 25 40A 010HP-208V ED1 175 15 46.2 32 50A 01-208V ED2 299 20 59.4 50 63A 020HP-208V ED2 309 25 74.8 63 80A 02-208V ED3 422 30 88 75 97A 030HP-208V ED3 422 230V 3/4 3.2 2.8 4.0A 0P7HP-230V ED1 110 1 4.2 4.0 6.3A 001HP-230V ED1 110 1-1/2 6.0 4.0 6.3A 1P-230V ED1 110 2 6.8 5.6 8.0A 002HP-230V ED1 110 3 9.6 7.0 10A O0-230V ED1 110 5 15.2 11 17A O0-230V ED1 117 7-1/2 22 15 23A O07HP-230V ED1 119 10 28 22 32A 010HP-230V ED1 167 15 42 32 50A 01-230V ED2 299 20 54 40 57A 020HP-230V ED2 309 25 68 57 70A 02-230V ED2 312 30 80 75 97A 030HP-230V ED3 422 40 104 90 112A 040HP-230V ED3 422 460V 1/2 1.1 0.8 1.2A 0P-460V ED1 110 1 2.1 1.8 2.8A 001HP-460V ED1 110 1-1/2 3.0 2.8 4.0A 1P-460V ED1 110 2 3.4 2.8 4.0A 002HP-460V ED1 110 3 4.8 4.0 6.3A O0-460V ED1 110 5 7.6 5.6 8.0A O0-460V ED1 110 7-1/2 11 8.0 12.5A O07HP-460V ED1 112 10 14 11 17A 010HP-460V ED1 117 15 21 15 23A 01-460V ED1 119 20 27 22 32A 020HP-460V ED1 167 30 40 32 50A 030HP-460V ED2 299 40 52 40 57A 040HP-460V ED2 309 50 65 57 70A 050HP-460V ED2 312 60 77 63 80A 060HP-460V ED3 422 75 96 75 97A 07-460V ED3 422 119 MOTOR CONTROLS www.factorymation.com/motorcontrols -SSTR -HOAP -STHR ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

120 Enclosed DOL Motor Starters www.factorymation.com/motorcontrols MOTOR CONTROLS Direct-On-Line, Non-reversing Product shown in picture includes optional items. Dimensional information is available on the last page of this section. DOL Motor Starters include contactor and thermal overload Single-phase 120V and 230V input voltage models available, 1/6HP to 10HP Hinged, UL Type rated enclosure Mechanical reset standard All components UL/CUL certified *Most standard models can ship within three business days. Build Your Part Number: Direct-On-Line Motor Starter Non-Reversing Horsepower DOLNRS - xxxhp - xxxv - Nxx - xxxx - xxxx UL Type Rating Control Voltage Operator Devices Options (select one of each) -LINE 0 Motor Voltage Control/Coil Voltage Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage Operator Devices -RSET 0 Reset Pushbutton Only -STSR 50 Start-Stop/Reset Pushbuttons -HOAS 50 Hand-Off-Auto Selector Switch and Reset Pushbutton 207 UP TO 10HP SHIPS IN 3 DAYS!* 120V, Single-phase Max. UL Ratings Current Trip Range 230V, Single-phase Part Number UL Type 4/12 UL Type 4X UL Type 4XSS 1/6 4.4 4.0 6.3A 0P1HP-120V EN1 207 PC1 218 SS1 363 1/4 5.8 4.0 6.3A 0P2HP-120V EN1 207 PC1 218 SS1 363 1/3 7.2 5.6 8.0A 0P-120V EN1 207 PC1 218 SS1 363 1/2 9.8 7.0 10A 0P-120V EN1 207 PC1 218 SS1 363 3/4 13.8 10 15A 0P7HP-120V EN1 228 PC1 239 SS1 384 1 16 11 17A 001HP-120V EN1 228 PC1 239 SS1 384 1-1/2 20 15 23A 1P-120V EN1 228 PC1 239 SS1 384 2 24 23 32A 002HP-120V EN2 311 PC1 322 SS2 499 3 34 25 40A 00-120V EN2 311 PC1 322 SS2 499 5 56 40 57A 00-120V EN2 311 PC1 322 SS2 499 208V, Single-phase -N04 -N4P -NSS DOLNRS- HP FLA DIM Price DIM Price DIM Price Max. UL Current Part Number UL Type 4/12 UL Type 4X UL Type 4XSS Ratings Trip -N04 -N4P -NSS Range DOLNRS- HP FLA DIM Price DIM Price DIM Price 1/6 2.2 1.8 2.8A 0P1HP-208V EN1 207 PC1 218 SS1 363 1/4 2.9 2.8 4.0A 0P2HP-208V EN1 207 PC1 218 SS1 363 1/3 3.6 2.8 4.0A 0P-208V EN1 207 PC1 218 SS1 363 1/2 4.9 4.0 6.3A 0P-208V EN1 207 PC1 218 SS1 363 3/4 6.9 5.6 8.0A 0P7HP-208V EN1 207 PC1 218 SS1 363 1 8.0 5.6 8.0A 001HP-208V EN1 228 PC1 239 SS1 384 1-1/2 10 7.0 10A 1P-208V EN1 228 PC1 239 SS1 384 2 12 8.0 12.5A 002HP-208V EN1 311 PC1 322 SS1 499 3 17 11 17A 00-208V EN1 311 PC1 322 SS1 499 5 28 23 32A 00-208V EN2 311 PC1 322 SS2 499 7-1/2 40 25 40A 007HP-208V EN2 311 PC1 322 SS2 499 10 50 32 50A 010HP-208V EN2 415 PC1 436 SS2 603 Max. UL Ratings Current Trip Range Part Number UL Type 4/12 UL Type 4X UL Type 4XSS -N04 -N4P -NSS DOLNRS- HP FLA DIM Price DIM Price DIM Price 1/6 2.2 1.8 2.8A 0P1HP-230V EN1 207 PC1 218 SS1 363 1/4 2.9 2.8 4.0A 0P2HP-230V EN1 207 PC1 218 SS1 363 1/3 3.6 2.8 4.0A 0P-230V EN1 207 PC1 218 SS1 363 1/2 4.9 4.0 6.3A 0P-230V EN1 207 PC1 218 SS1 363 3/4 6.9 5.6 8.0A 0P7HP-230V EN1 207 PC1 218 SS1 363 1 8.0 5.6 8.0A 001HP-230V EN1 228 PC1 239 SS1 384 1-1/2 10 7.0 10A 1P-230V EN1 228 PC1 239 SS1 384 2 12 8.0 12.5A 002HP-230V EN1 311 PC1 322 SS1 499 3 17 11 17A 00-230V EN1 311 PC1 322 SS1 499 5 28 23 32A 00-230V EN2 311 PC1 322 SS2 499 7-1/2 40 25 40A 007HP-230V EN2 311 PC1 322 SS2 499 10 50 32 50A 010HP-230V EN2 415 PC1 436 SS2 603 Selection QueStionS? Our motor starters are custom-built to customer specifications. If you need assistance selecting a motor starter, contact FactoryMation Technical Support @ 1.800.972.0436 To Order Call 1.800.972.0436 or Visit factorymation.com

Enclosed DOL Motor Starters (cont d) Direct-On-Line, Non-reversing Product shown in picture includes optional items. Dimensional information is available on the last page of this section. DOL Motor Starters include contactor and thermal overload Three-phase 208V, 230V, and 460V input voltage models available, 1/2HP to 7 Hinged, UL Type-rated enclosure Mechanical reset standard All components UL/CUL certified *Most standard models can ship within three business days. Build Your Part Number: Direct-On-Line Motor Starter Non-Reversing Horsepower Motor Voltage DOLNR - xxxhp - xxxv - Nxx - xxxx - xxxx UL Type Rating Control Voltage Operator Devices Options (select one of each) Control/Coil Voltage -LINE 0 Motor Voltage and Control/Coil Voltages are internally connected -X024 0 Externally supplied 24VAC Control/Coil Voltage -X120 0 Externally supplied 120VAC Control/Coil Voltage -X208 0 Externally supplied 208VAC Control/Coil Voltage -X230 0 Externally supplied 230VAC Control/Coil Voltage Operator Devices -RSET 0 Reset Pushbutton Only -STSR 50 Start-Stop/Reset Pushbuttons -HOAS 50 Hand-Off-Auto Selector Switch and Reset Pushbutton 207 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase 230V, Three-phase 460V, Three-phase Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 4XSS Ratings Current -N04 -N4P -NSS Trip Range DOLNR- HP FLA DIM Price DIM Price DIM Price 1/2 2.4 1.8 2.8A 0P-208V EN1 207 PC1 218 SS1 363 3/4 3.5 2.8 4.0A 0P7HP-208V EN1 207 PC1 218 SS1 363 1 4.6 4.0 6.3A 001HP-208V EN1 207 PC1 218 SS1 363 1-1/2 6.6 5.6 8.0A 1P-208V EN1 207 PC1 218 SS1 363 2 7.5 5.6 8.0A 002HP-208V EN1 207 PC1 218 SS1 363 3 10.6 8.0 12.5A 00-208V EN1 207 PC1 218 SS1 363 5 16.7 11 17A 00-208V EN1 228 PC1 239 SS1 384 7-1/2 24.2 23 32A 007HP-208V EN1 228 PC1 239 SS1 384 10 30.8 25 40A 010HP-208V EN2 311 PC1 322 SS2 499 15 46.2 32 50A 01-208V EN2 311 PC1 322 SS2 499 20 59.4 50 63A 020HP-208V EN2 311 PC1 322 SS2 499 25 74.8 63 80A 02-208V EN3 415 PC1 322 SS2 499 30 88 75 97A 030HP-208V EN3 415 PC2 436 SS3 603 Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 4XSS Ratings Current -N04 -N4P -NSS Trip Range DOLNR- HP FLA DIM Price DIM Price DIM Price 1/2 2.2 1.8 2.8A 0P-230V EN1 207 PC1 218 SS1 363 3/4 3.2 2.8 4.0A 0P7HP-230V EN1 207 PC1 218 SS1 363 1 4.2 4.0 6.3A 001HP-230V EN1 207 PC1 218 SS1 363 1-1/2 6 4.0 6.3A 1P-230V EN1 207 PC1 218 SS1 363 2 6.8 5.6 8.0A 002HP-230V EN1 207 PC1 218 SS1 363 3 9.6 7.0 10A 00-230V EN1 207 PC1 218 SS1 363 5 15.2 11 17A 00-230V EN1 228 PC1 239 SS1 384 7-1/2 22 15 23A 007HP-230V EN1 228 PC1 239 SS1 384 10 28 25 40A 010HP-230V EN2 311 PC1 322 SS2 499 15 42 32 50A 01-230V EN2 311 PC1 322 SS2 499 20 54 40 57A 020HP-230V EN2 311 PC1 322 SS2 499 25 68 57 70A 02-230V EN3 415 PC1 322 SS2 499 30 80 63 80A 030HP-230V EN3 415 PC2 436 SS3 603 Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 4XSS Ratings Current -N04 -N4P -NSS Trip Range DOLNR- HP FLA DIM Price DIM Price DIM Price 1/2 1.1 0.8 1.2A 0P-460V EN1 207 PC1 218 SS1 363 3/4 1.6 1.2 1.8A 0P7HP-460V EN1 207 PC1 218 SS1 363 1 2.1 1.8 2.8A 001HP-460V EN1 207 PC1 218 SS1 363 1-1/2 3 2.8 4.0A 1P-460V EN1 207 PC1 218 SS1 363 2 3.4 2.8 4.0A 002HP-460V EN1 207 PC1 218 SS1 363 3 4.8 4.0 6.3A 00-460V EN1 207 PC1 218 SS1 363 5 7.6 5.6 8.0A 00-460V EN1 207 PC1 218 SS1 363 7-1/2 11 8.0 12.5A 007HP-460V EN1 207 PC1 218 SS1 363 10 14 10 15A 010HP-460V EN1 228 PC1 239 SS1 384 15 21 15 23A 01-460V EN1 228 PC1 239 SS1 384 20 27 25 40A 020HP-460V EN1 228 PC1 239 SS1 384 25 34 25 40A 02-460V EN2 311 PC1 322 SS2 499 30 40 25 40A 030HP-460V EN2 311 PC1 322 SS2 499 40 52 40 57A 040HP-460V EN2 311 PC1 322 SS2 499 50 65 57 70A 050HP-460V EN2 311 PC1 322 SS2 499 60 77 63 80A 060HP-460V EN3 415 PC2 436 SS3 603 75 96 75 97A 07-460V EN3 415 PC2 436 SS3 603 121 MOTOR CONTROLS www.factorymation.com/motorcontrols ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

122 www.factorymation.com/motorcontrols MOTOR CONTROLS Economy Combination Motor Starters Non-reversing Dimensional information is available on the last page of this section. Manual Motor Starter with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 7 Enclosure choices that meet your application requirements *Most standard models can ship within three business days. Build Your Part Number: Economy Combination Motor Starter Non-Reversing Horsepower Disconnect Type ECMSNR - xxxhp - MP - xxxv - N4P - 00000 - xxxx - 00 UL Type Rating Control Transformer Operator Devices Pilot Light Options (select one of each) -00000 0 None Control Transformer Operator Devices -STSP 50 Start-Stop Pushbuttons -HOAS 50 Hand-Off-Auto Selector Switch Motor Voltage -N024 0 No operators, 24VAC/60Hz Coil for remote op -N120 0 No operators, 120VAC/60Hz Coil for remote op -N208 0 No operators, 208VAC/60Hz Coil for remote op -N230 0 No operators, 230VAC/60Hz Coil for remote op -N460 0 No operators, 480VAC/60Hz Coil for remote op -00 0 None Pilot Lights 311 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase 230V, Three-phase 460V, Three-phase Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSNR- HP FLA DIM Price 1/2 2.4 1.6 2.5A 0P-MP-208V PC1 311 3/4 3.5 2.5 4.0A 0P7HP-MP-208V PC1 311 1 4.6 4.0 6.0A 001HP-MP-208V PC1 311 1-1/2 6.6 6.3 10A 1P-MP-208V PC1 311 2 7.5 5.0 8.0A 002HP-MP-208V PC1 311 3 10.6 9.0 13A 00-MP-208V PC1 311 5 16.7 14 22A 00-MP-208V PC1 311 7-1/2 24.2 18 26A 007HP-MP-208V PC1 311 10 30.8 28 40A 010HP-MP-208V PC1 467 15 46.2 34 50A 01-MP-208V PC3 467 20 59.4 45 63A 020HP-MP-208V PC3 467 25 74.8 70 90A 02-MP-208V PC3 675 30 88 80 100A 030HP-MP-208V PC3 675 Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSNR- HP FLA DIM Price 1/2 2.2 1.6 2.5A 0P-MP-230V PC1 311 3/4 3.2 2.5 4.0A 0P7HP-MP-230V PC1 311 1 4.2 4.0 6.3A 001HP-MP-230V PC1 311 1-1/2 6.0 4.0 6.0A 1P-MP-230V PC1 311 2 6.8 5.0 8.0A 002HP-MP-230V PC1 311 3 9.6 6.0 10A 00-MP-230V PC1 311 5 15.2 11 17A 00-MP-230V PC1 311 7-1/2 22 14 22A 007HP-MP-230V PC1 311 10 28 22 32A 010HP-MP-230V PC1 311 15 42 34 50A 01-MP-230V PC3 467 20 54 45 63A 020HP-MP-230V PC3 467 25 68 55 75A 02-MP-230V PC3 675 30 80 70 90A 030HP-MP-230V PC3 675 Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSNR- HP FLA DIM Price 1/2 1.1 1.0 1.6A 0P-MP-460V PC1 311 1 2.1 1.6 2.5A 001HP-MP-460V PC1 311 1-1/2 3 2.5 4.0A 1P-MP-460V PC1 311 2 3.4 2.5 4.0A 002HP-MP-460V PC1 311 3 4.8 4.0 6.0A 00-MP-460V PC1 311 5 7.6 5.0 8.0A 00-MP-460V PC1 311 7-1/2 11 9.0 13A 007HP-MP-460V PC1 311 10 14 11 17A 010HP-MP-460V PC1 311 15 21 14 22A 01-MP-460V PC1 311 20 27 22 32A 020HP-MP-460V PC1 311 25 34 28 40A 02-MP-460V PC1 467 30 40 34 50A 030HP-MP-460V PC3 467 40 52 45 63A 040HP-MP-460V PC3 467 50 65 55 75A 050HP-MP-460V PC3 675 60 77 70 90A 060HP-MP-460V PC3 675 75 96 80 100A 07-MP-460V PC3 675 To Order Call 1.800.972.0436 or Visit factorymation.com

Economy Combination Motor Starters (cont d) Reversing Dimensional information is available on the last page of this section. Manual Motor Starter with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 7 Enclosure choices that meet your application requirements *Most standard models can ship within three business days. Build Your Part Number: Economy Combination Motor Starter Reversing Options (select one of each) -00000 0 None Control Transformer Operator Devices Pilot Lights -FSRV 75 Forward-Stop-Reverse Pushbuttons -FORV 75 Forward-Off-Reverse Selector Switch -N024 0 No operators, 24VAC/60Hz Coil for remote op -N120 0 No operators, 120VAC/60Hz Coil for remote op -N208 0 No operators, 208VAC/60Hz Coil for remote op -N230 0 No operators, 230VAC/60Hz Coil for remote op -N460 0 No operators, 480VAC/60Hz Coil for remote op -00 0 None Pilot Lights 415 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase 1/2 2.4 1.6 2.5A 0P-MP-208V PC2 415 3/4 3.5 2.5 4.0A 0P7HP-MP-208V PC2 415 1 4.6 4.0 6.0A 001HP-MP-208V PC2 415 1-1/2 6.6 6.3 10A 1P-MP-208V PC2 415 2 7.5 5.0 8.0A 002HP-MP-208V PC2 415 3 10.6 9.0 13A 00-MP-208V PC2 415 5 16.7 14 22A 00-MP-208V PC2 415 7-1/2 24.2 18 26A 007HP-MP-208V PC2 415 10 30.8 28 40A 010HP-MP-208V PC3 623 15 46.2 34 50A 01-MP-208V PC3 623 20 59.4 45 63A 020HP-MP-208V PC3 623 25 74.8 70 90A 02-MP-208V PC3 831 30 88 80 100A 030HP-MP-208V PC3 831 230V, Three-phase 1/2 2.2 1.6 2.5A 0P-MP-230V PC2 415 3/4 3.2 2.5 4.0A 0P7HP-MP-230V PC2 415 1 6.0 4.0 6.3A 001HP-MP-230V PC2 415 1-1/2 6.0 4.0 6.0A 1P-MP-230V PC2 415 2 6.8 5.0 8.0A 002HP-MP-230V PC2 415 3 9.6 6.0 10A 00-MP-230V PC2 415 5 15.2 11 17A 00-MP-230V PC2 415 7-1/2 22 14 22A 007HP-MP-230V PC2 415 10 28 22 32A 010HP-MP-230V PC2 415 15 42 34 50A 01-MP-230V PC3 623 20 54 45 63A 020HP-MP-230V PC3 623 25 68 55 75A 02-MP-230V PC3 831 30 80 70 90A 030HP-MP-230V PC3 831 460V, Three-phase Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSRV- HP FLA DIM Price Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSRV- HP FLA DIM Price Part Number UL Type 4X Max. UL Ratings Current -N4P Trip Range ECMSRV- HP FLA DIM Price 1/2 1.1 1.0 1.6A 0P-MP-460V PC2 415 1 2.1 1.6 2.5A 001HP-MP-460V PC2 415 1-1/2 3.0 2.5 4.0A 1P-MP-460V PC2 415 2 3.4 2.5 4.0A 002HP-MP-460V PC2 415 3 4.8 4.0 6.0A 00-MP-460V PC2 415 5 7.6 5.0 8.0A 00-MP-460V PC2 415 7-1/2 11 9.0 13A 007HP-MP-460V PC2 415 10 14 11 17A 010HP-MP-460V PC2 415 15 21 14 22A 01-MP-460V PC2 415 20 27 22 32A 020HP-MP-460V PC2 415 25 34 28 40A 02-MP-460V PC3 623 30 40 34 50A 030HP-MP-460V PC3 623 40 52 45 63A 040HP-MP-460V PC3 623 50 65 55 75A 050HP-MP-460V PC3 831 60 77 70 90A 060HP-MP-460V PC3 831 75 96 80 100A 07-MP-460V PC3 831 123 MOTOR CONTROLS www.factorymation.com/motorcontrols ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

124 www.factorymation.com/motorcontrols MOTOR CONTROLS Combination Motor Starters Non-reversing Dimensional information is available on the last page of this section. Manual Motor Starter with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 7 Enclosure choices that meet your application requirements *Most standard models can ship within three business days. Build Your Part Number: Combination Motor Starter Non-Reversing Horsepower Disconnect Type CMSNR - xxxhp - MP - xxxv- Nxx - 120XF - xxxx - PL UL Type Rating Control Transformer Operator Devices Pilot Light Options (select one of each) Control Transformer Motor Voltage -120XF 0 Primary same as input voltage, 120V Secondary Operator Devices -STSP 0 Start-Stop Pushbuttons -HOAS 0 Hand-Off-Auto Selector Switch Pilot Lights -PL 0 Pilot light, RED, indicates when starter is ON 519 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSNR- HP FLA DIM Price DIM Price DIM Price DIM Price Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSNR- HP FLA DIM Price DIM Price DIM Price DIM Price 1/2 2.4 1.6 2.5A 0P-MP-208V EL1 519 U1 571 R1 519 S1 831 3/4 3.5 2.5 4.0A 0P7HP-MP-208V EL1 519 U1 571 R1 519 S1 831 1 4.6 4.0 6.0A 001HP-MP-208V EL1 519 U1 571 R1 519 S1 831 1-1/2 6.6 6.3 10A 1P-MP-208V EL1 519 U1 571 R1 519 S1 831 2 7.5 5.0 8.0A 002HP-MP-208V EL1 519 U1 571 R1 519 S1 831 3 10.6 9.0 13A 00-MP-208V EL1 519 U1 571 R1 519 S1 831 5 16.7 14 22A 00-MP-208V EL1 519 U1 571 R1 519 S1 831 7-1/2 24.2 18 26A 007HP-MP-208V EL1 519 U1 571 R1 519 S1 831 10 30.2 28 40A 010HP-MP-208V EL1 675 U1 779 R1 675 S1 1,143 15 46.2 34 50A 01-MP-208V EL2 675 U2 779 R2 675 S2 1,143 20 59.4 45 63A 020HP-MP-208V EL2 675 U2 779 R2 675 S2 1,143 25 74.8 70 90A 02-MP-208V EL3 883 U3 1,091 R3 883 S3 1,351 30 88 80 100A 030HP-MP-208V EL3 883 U3 1,091 R3 883 S3 1,351 230V, Three-phase 1/2 2.2 1.6 2.5A 0P-MP-230V EL1 519 U1 571 R1 519 S1 831 3/4 3.2 2.5 4.0A 0P7HP-MP-230V EL1 519 U1 571 R1 519 S1 831 1 4.2 4.0 6.3A 001HP-MP-230V EL1 519 U1 571 R1 519 S1 831 1-1/2 6.0 4.0 6.0A 1P-MP-230V EL1 519 U1 571 R1 519 S1 831 2 6.8 5.0 8.0A 002HP-MP-230V EL1 519 U1 571 R1 519 S1 831 3 9.6 6.0 10A 00-MP-230V EL1 519 U1 571 R1 519 S1 831 5 15.2 11 17A 00-MP-230V EL1 519 U1 571 R1 519 S1 831 7-1/2 22 14 22A 007HP-MP-230V EL1 519 U1 571 R1 519 S1 831 10 28 22 32A 010HP-MP-230V EL1 519 U1 571 R1 519 S1 831 15 42 34 50A 01-MP-230V EL2 675 U2 779 R2 675 S2 1,143 20 54 45 63A 020HP-MP-230V EL2 675 U2 779 R2 675 S2 1,143 25 68 55 75A 02-MP-230V EL3 883 U3 1,091 R3 883 S3 1,351 30 80 70 90A 030HP-MP-230V EL3 883 U3 1,091 R3 883 S3 1,351 460V, Three-phase Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSNR- HP FLA DIM Price DIM Price DIM Price DIM Price 1/2 1.1 1.0 1.6A 0P-MP-460V EL1 519 U1 571 R1 519 S1 831 1 2.1 1.6 2.5A 001HP-MP-460V EL1 519 U1 571 R1 519 S1 831 1-1/2 3 2.5 4.0A 1P-MP-460V EL1 519 U1 571 R1 519 S1 831 2 3.4 2.5 4.0A 002HP-MP-460V EL1 519 U1 571 R1 519 S1 831 3 4.8 4.0 6.0A 00-MP-460V EL1 519 U1 571 R1 519 S1 831 5 7.6 5.0 8.0A 00-MP-460V EL1 519 U1 571 R1 519 S1 831 7-1/2 11 9.0 13A 007HP-MP-460V EL1 519 U1 571 R1 519 S1 831 10 14 11 17A 010HP-MP-460V EL1 519 U1 571 R1 519 S1 831 15 21 14 22A 01-MP-460V EL1 519 U1 571 R1 519 S1 831 20 27 22 32A 020HP-MP-460V EL1 519 U1 571 R1 519 S1 831 25 34 28 40A 02-MP-460V EL2 675 U2 779 R2 675 S2 1,143 30 40 34 50A 030HP-MP-460V EL2 675 U2 779 R2 675 S2 1,143 40 52 45 63A 040HP-MP-460V EL2 675 U2 779 R2 675 S2 1,143 50 65 55 75A 050HP-MP-460V EL3 883 U3 1,091 R3 883 S3 1,351 60 77 70 90A 060HP-MP-460V EL3 883 U3 1,091 R3 883 S3 1,351 75 96 80 100A 07-MP-460V EL3 883 U3 1,091 R3 883 S3 1,351 To Order Call 1.800.972.0436 or Visit factorymation.com

Combination Motor Starters (cont d) Reversing Dimensional information is available on the last page of this section. Manual Motor Starter with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 7 Enclosure choices that meet your application requirements *Most standard models can ship within three business days. Build Your Part Number: Combination Motor Starter Reversing Horsepower Disconnect Type CMSRV - xxxhp - MP - xxxv- Nxx - 120XF- xxxx - PL2 UL Type Rating Control Transformer Operator Devices Pilot Lights Options (select one of each) Control Transformer Motor Voltage -120XF 0 Primary same as input voltage, 120V Secondary Operator Devices -FSRV 0 Forward-Stop-Reverse Pushbuttons -FORV 0 Forward-Off-Reverse Selector Switch Pilot Lights -PL2 0 Pilot lights, 1-FWD, 1-REV 623 UP TO 7 SHIPS IN 3 DAYS!* 208V, Three-phase 1/2 2.4 1.6 2.5A 0P-MP-208V EL1 623 U1 675 R1 623 S1 935 3/4 3.5 2.5 4.0A 0P7HP-MP-208V EL1 623 U1 675 R1 623 S1 935 1 4.6 4.0 6.0A 001HP-MP-208V EL1 623 U1 675 R1 623 S1 935 1-1/2 6.6 5.6 8.0A 1P-MP-208V EL1 623 U1 675 R1 623 S1 935 2 7.5 5.0 8.0A 002HP-MP-208V EL1 623 U1 675 R1 623 S1 935 3 10.6 9.0 13A 00-MP-208V EL1 623 U1 675 R1 623 S1 935 5 16.7 14 22A 00-MP-208V EL1 623 U1 675 R1 623 S1 935 7-1/2 24.2 18 26A 007HP-MP-208V EL1 623 U1 675 R1 623 S1 935 10 30.2 28 40A 010HP-MP-208V EL1 831 U1 935 R1 831 S1 1,299 15 46.2 34 50A 01-MP-208V EL2 831 U2 935 R2 831 S2 1,299 20 59.4 45 63A 020HP-MP-208V EL2 831 U2 935 R2 831 S2 1,299 25 74.8 70 90A 02-MP-208V EL3 1,039 U4 1,247 R3 1,039 S3 1,507 30 88 80 100A 030HP-MP-208V EL3 1,039 U4 1,247 R3 1,039 S3 1,507 230V, Three-phase 1/2 2.2 1.6 2.5A 0P-MP-230V EL1 623 U1 675 R1 623 S1 935 3/4 3.2 2.5 4.0A 0P7HP-MP-230V EL1 623 U1 675 R1 623 S1 935 1 4.2 4.0 6.3A 001HP-MP-230V EL1 623 U1 675 R1 623 S1 935 1-1/2 6.0 4.0 6.0A 1P-MP-230V EL1 623 U1 675 R1 623 S1 935 2 6.8 5.0 8.0A 002HP-MP-230V EL1 623 U1 675 R1 623 S1 935 3 9.6 6.0 10A 00-MP-230V EL1 623 U1 675 R1 623 S1 935 5 15.2 11 17A 00-MP-230V EL1 623 U1 675 R1 623 S1 935 7-1/2 22 14 22A 007HP-MP-230V EL1 623 U1 675 R1 623 S1 935 10 28 22 32A 010HP-MP-230V EL1 623 U1 675 R1 623 S1 935 15 42 34 50A 01-MP-230V EL2 831 U2 935 R2 831 S2 1,299 20 54 45 63A 020HP-MP-230V EL2 831 U2 935 R2 831 S2 1,299 25 68 55 75A 02-MP-230V EL3 1,039 U4 1,247 R3 1,039 S3 1,507 30 80 70 90A 030HP-MP-230V EL3 1,039 U4 1,247 R3 1,039 S3 1,507 460V, Three-phase Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSRV- HP FLA DIM Price DIM Price DIM Price DIM Price Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSRV- HP FLA DIM Price DIM Price DIM Price DIM Price Max. UL Part Number UL Type 4/12 UL Type 4X UL Type 3R UL Type 4XSS Ratings Current -N04 -N4X -N3R -NSS Trip Range CMSRV- HP FLA DIM Price DIM Price DIM Price DIM Price 1/2 1.1 1.0 1.6A 0P-MP-460V EL1 623 U1 675 R1 623 S1 935 1 2.1 1.6 2.5A 001HP-MP-460V EL1 623 U1 675 R1 623 S1 935 1-1/2 3 2.5 4.0A 1P-MP-460V EL1 623 U1 675 R1 623 S1 935 2 3.4 2.5 4.0A 002HP-MP-460V EL1 623 U1 675 R1 623 S1 935 3 4.8 4.0 6.0A 00-MP-460V EL1 623 U1 675 R1 623 S1 935 5 7.6 5.0 8.0A 00-MP-460V EL1 623 U1 675 R1 623 S1 935 7-1/2 11 9.0 13A 007HP-MP-460V EL1 623 U1 675 R1 623 S1 935 10 14 11 17A 010HP-MP-460V EL1 623 U1 675 R1 623 S1 935 15 21 14 22A 01-MP-460V EL1 623 U1 675 R1 623 S1 935 20 27 22 32A 020HP-MP-460V EL1 623 U1 675 R1 623 S1 935 25 34 28 40A 02-MP-460V EL1 831 U1 935 R1 831 S1 1,299 30 40 34 50A 030HP-MP-460V EL2 831 U2 935 R2 831 S2 1,299 40 52 45 63A 040HP-MP-460V EL2 831 U2 935 R2 831 S2 1,299 50 65 55 75A 050HP-MP-460V EL3 1,039 U4 1,247 R3 1,039 S3 1,507 60 77 70 90A 060HP-MP-460V EL3 1,039 U4 1,247 R3 1,039 S3 1,507 75 96 80 100A 07-MP-460V EL3 1,039 U4 1,247 R3 1,039 S3 1,507 125 MOTOR CONTROLS www.factorymation.com/motorcontrols ONLINE ORDERS FREESHIPPING SMALL PACKAGES MIN. 29 LTL FREIGHT MIN. SEE INSIDE BACK COVER FOR MORE DETAILS

126 Combination Motor Starters (cont d) QUICKLY LINK TO OUR PRODUCTS ONLINE www.factorymation.com/ www.factorymation.com/motorcontrols MOTOR CONTROLS Combination Starter with Thermal Magnetic Circuit Breaker cmsnr-cb Combination Starter with Fusible Disconnect 671 UP TO 200HP SHIPS IN 3 DAYS!* MCCB with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 200HP Enclosure choices that meet your application requirements *Built to order. Most standard models can ship within three business days. 578 UP TO 200HP SHIPS IN 3 DAYS!* Fusible disconnect: power disconnect + circuit protection Disconnects accept J-type fuses (power fuses not provided) 208V, 230V, and 460V input voltage models up to 200HP Enclosure choices that meet your application requirements *Built to order. Most standard models can ship within three business days. Dimensional information is available on the last page of this section. Reversing Combination Starter with Thermal Magnetic Circuit Breaker cmsrv-cb 848 UP TO 200HP Reversing Combination Starter with Fusible Disconnect 723 UP TO 200HP SHIPS IN 3 DAYS!* MCCB with disconnect handle: power disconnect + circuit protection 208V, 230V, and 460V input voltage models up to 200HP Enclosure choices that meet your application requirements *Built to order. Most standard models can ship within three business days. SHIPS IN 3 DAYS!* Fusible disconnect: power disconnect + circuit protection Disconnects accept J-type fuses (power fuses not provided) 208V, 230V, and 460V input voltage models up to 200HP Enclosure choices that meet your application requirements *Built to order. Most standard models can ship within three business days. cmsnr-fd cmsrv-fd Combination Soft Starter Modified/Custom Motor Control Panels 1,534 UP TO 1200HP 5 to 1200 HP 230 or 460VAC UL Type 1/12, 3R, 4 (optional rain shield) Multiple configuration options available Features Variable Speed AC Drive Panels Pump Controllers Reduced Voltage Starters And More! cssw custom-control-panels To Order Call 1.800.972.0436 or Visit factorymation.com