SilverStorm Table of Contents

Similar documents
QLogic Family of QDR InfiniBand Switches. Table of Contents

QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4. Table of Contents

QLogic QDR InfiniBand Switch. Table of Contents

QLogic InfiniBand Cluster Planning Guide

[ Quick Start Guide ]

HP BLc QLogic 4X QDR InfiniBand Switch Release Notes. Firmware Version

Intel True Scale Fabric Switches Series

HP BLc Intel 4X QDR InfiniBand Switch Release Notes. Firmware Version

[ Quick Start Guide ]

True Scale Fabric Switches Series

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents

About Chassis Manager

SANsurfer Converged Network Adapter Networking CLI. Table of Contents

SANsurfer Fibre Channel (FC) HBA Manager. Table of Contents

D Rev. B. SilverStorm 9000 CLI Reference Guide

Multi-boot Image for Qxx8xxx Converged Network Adapters. Table of Contents

InfiniPath Drivers and Software for QLogic QHT7xxx and QLE7xxx HCAs. Table of Contents

D QLogic InfiniBand Adapter Hardware Install Guide

QLogic BS21, , and InfiniBand Switches IBM Power at-a-glance guide

Appendix A Fast!UTIL

Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents

[ Quick Start Guide ]

FC HBA Driver for NetWare. Table of Contents

Maintenance Tasks CHAPTER

Maintenance Tasks CHAPTER

[ Quick Start Guide ]

Fibre Channel Adapter STOR Miniport Driver for Windows. Table of Contents

Maintenance Tasks. About A/B Partition CHAPTER

Intel Entry Storage System SS4000-E

10GbE Converged Network Adapter NDIS Miniport Driver for Windows. Table of Contents

Release Notes: J-Web Application Package Release 15.1A1 for Juniper Networks EX Series Ethernet Switches

BIOS for QLA4010 iscsi HBAs. Table of Contents

SANsurfer iscsi Host Bus Adapter CLI. Table of Contents

Intel Omni-Path Fabric Switches

Intel Entry Storage System SS4000-E

[ Quick Start Guide ]

Fibre Channel Switch Interoperability Guide

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents

Release Notes: J-Web Application Package Release 15.1A4 for Juniper Networks EX Series Ethernet Switches

FC HBA STOR Miniport Driver for Windows. Table of Contents

Switch Interoperability Guide

RELEASE NOTES: Web OS Great America Parkway Santa Clara, CA Phone Nortel

SANsurfer Fibre Channel Command Line Interface (CLI) Table of Contents

Release Notes. Network Resource Manager 1.0 NRM 1.0

[ Quick Start Guide ]

Element Manager User Guide Release 2.3.0

V10.18 Unified Firmware Update. Release Notes & Installation Instructions

SANsurfer Pro Application Notes. Table of Contents

Secure Fabric OS. QuickStart Guide. Supporting Fabric OS v3.2.0, v Supporting SilkWorm 3016, 3200, 3250, 3800, 3850, 3900, 4100, 12000, 24000

V10.16 Unified Firmware Update. Release Notes & Installation Instructions

C H A P T E R Commands Cisco SFS Product Family Command Reference OL

Linksys Stackable Switches

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00109, SEPTEMBER 8, Release Notes Section Outline

Cisco ACI Cluster Management

Restoring an SP Boot Image

SANsurfer iscsi HBA Application User s Guide

SANsurfer iscsi HBA CLI. Table of Contents

LSISAS6160 SAS Switch r Firmware

C H A P T E R InfiniBand Commands Cisco SFS 7000 Series Product Family Command Reference Guide OL

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

Release Notes for Cisco UCS Platform Emulator, Release 3.1(1ePE1)

About Element Manager

Fibre Channel QLA Driver for Solaris SPARC and x86 Platforms. Table of Contents

Configuring the MSA1000 for Linux or NetWare Environments

SANsurfer FC HBA Manager. Table of Contents

Express5800/320La System Release Notes

Release Notes: J-Web Application Package Release 17.4A1 for EX4300 and EX4600 Switches

Windows SuperInstaller Readme. QLogic Corporation All rights reserved. Table of Contents

An Enhanced Redundancy Configuration for the Avaya S8700 Media Server Issue 1.2

VTRAK E-Class/J-Class Quick Start Guide

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter

Release Notes Maintenance

[ Quick Start Guide ]

Flash Image for 3200 and 8200 Series Adapters. Table of Contents

Dell EMC ME4 Series Storage Systems. Release Notes

Installing the Cisco Unified Videoconferencing 3545 MCU

Emulex OneCommand Manager Application for LightPulse Adapters for Windows Release Notes

StorageWorks Dual Channel 4Gb, PCI-X-to-Fibre Channel Host Bus Adapter for Windows and Linux (Emulex LP11002)

About Element Manager

OPTICAL TRANSPORT SYSTEM SOFTWARE RELEASE NOTES

Software Images. About Software Images. Dependent Factors. Send documentation comments to CHAPTER

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

QConvergeConsole. Table of Contents

StorNext M440 Metadata Appliance Release Notes

Upgrading the MSA1000 for Enhanced Features

VessRAID 1000s/1000i Series Service Release Notes

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

TFC-1600MM Media Conversion System. Management Configuring Guide

Thunderbolt(TM) Software Release Notes This document is the release notes for the Thunderbolt software version

[ Quick Start Guide ]

OpenFabrics Alliance Interoperability Working Group (OFA-IWG)

SmartZone G5 Firmware Release Notes 2.2.2

TESLA C2050 COMPUTING SYSTEM

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents

HPE FlexFabric 12900E & 12900

SANbox 5000 Series Stackable Switches

Intel Omni-Path Fabric Switches GUI

AM-101 AM-101AirMedia Presentation Gateway. Supplemental Guide Crestron Electronics, Inc.

IBM Storage Host Attachment Kit for AIX Version Release Notes IBM

Installing and Managing the Switch

Transcription:

SilverStorm 9000 This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. Version 2. Changes 3. Bug Fixes 4. Known Issues 5. Additional Information 6. Trademarks 7. Notices 8. Contacting Support 1. Version These release notes describe the changes, fixes, known issues, and release details that apply to the SilverStorm 9000 switches, version 4.2.2.0.2. 2. Changes The following changes and fixes have been made between versions 4.2.1.1.1 and 4.2.2.0.2. Hardware Support None OS Support None SilverStorm 9000 4.2.2.0.2 Release Notes 1 of 6

Software Components For added security, the CLI command "uiconfig" can disable non-secure methods of connecting to the switch, such as telnet, HTTP, FTP and SNMP. New CLI command "logsyslogtest" sends a test message of specified severity (error, warning, or notice) to the syslog server. The number of virtual lanes can now be specified with a new option for the CLI command "ismchassissetmtu". To better identify link problems, DDR-capable links that negotiate to a slower speed are highlighted in red on the GUI's IB Port Statistics screen. The "swapbsdel" setting is now saved per user, and will persist across multiple CLI sessions. New CLI command "setibnodedescformat" can configure the verbosity of the IB SMA node descriptions. Industry Standards Compliance N/A Miscellaneous (9000 Common) This release now includes Mellanox Anafa II firmware level 1.0.4 rc 14. (9000 MPFD only) Because the 'reboot now all' command does not work properly in 4.0.3.0.8, and the FVIC card is not rebooted after this command is issued, when upgrading a chassis and an FVIC from 4.0.3.0.8 to 4.2.2.0.2, the user will need to reboot the chassis a second time after it comes up with 4.2.2.0.2. 3. Bug Fixes The following fixes have been made between versions 4.2.1.1.1 and 4.2.2.0.2: 9000 Series Common: CLI command "loginmode" now has a good return code. The deprecated "No Operator Access" login mode has been removed from the GUI menu. If database synchronization fails, it will correctly attempt to re-sync after the retry period. 1x link mode on a standby SM can no longer affect the fabric. SDR link width value for spines is now correctly displayed in the GUI. File size limit has been removed from SRP configurations. Subnet manager log messages for node appearance and disappearance now contain a "LINKEDTO" field. 9024 Specific: Switch resets no longer cause symbol errors on ports 13 or 23 of the 9024. SilverStorm 9000 4.2.2.0.2 Release Notes 2 of 6

9020 Specific: The IPoIB commands for the 9020 no longer appear in the 9020 CLI, since the 9020 shuttle does not support IPoIB. 9040 Specific: 9080 Specific: 9120 Specific: 9240 Specific: VIO (EVIC and FVIC) Common: FVIC Specific: Manual FVIC configuration backup and restore now operates reliably. Certain hexadecimal values in SRP maps no longer cause parse errors when restoring the configuration. Automatic configuration restoration on a newly inserted FVIC now works correctly. EVIC Specific: Configuring manual link aggregation will no longer cause occasional errors. Miscellaneous: SilverStorm 9000 4.2.2.0.2 Release Notes 3 of 6

4. Known Issues Known Issue (9000 Common) If thresholds for symbol errors have been set (ismsetpstatthresh) and a host directly-attached to the switch is rebooted, the user will see a message similar to the following in the switch log: MasterSpine1-> W 2006/07/11 13:47:29.640D: Thread "ibstatthr" (0x868a3d80) TMS: Infiniband Error Statistic Overlimit: icsibstatmib: portsymbolerr Port name: L04P03 Id : 0 Rate: 65535 Threshold: 1 W 2006/07/11 13:47:30.640D: Thread "ibstatthr" (0x868a3d80) (9040 through 9240 only): Power cycling the chassis by disconnecting the power cords causes leaf or IB ports to hang. (9024): If the SilverStorm 9024 is shipped with only one (1) power supply, it will be installed in the right power supply slot. The left slot will be populated with a power supply blank (no LED) to maintain the thermal integrity of the chassis. With only one power supply, the chassis status LED will never be green. It will always be amber. (9000 Common): TimezoneDaylight Saving Time (DST) setting does not allow DST-start month to be greater than DST-end month. (9000 Common): The following CLI commands are not supported in this release: IpoIbConfigEnable IpoIbConfigShow IpoIbAddressShow IpoIbAddressSet Workaround These errors can be safely ignored. After unplugging the power cord(s), wait approximately one (1) minute before reinserting. For locations in the southern hemisphere, set the DST time manually. SilverStorm 9000 4.2.2.0.2 Release Notes 4 of 6

5. Additional Information Included in this release: SilverStorm 9000 Firmware version 4.2.2.0.2 for the following switches: SilverStorm 9024 SilverStorm 9020 SilverStorm 9040 SilverStorm 9080 SilverStorm 9120 SilverStorm 9240 NOTE: SilverStorm 9000 BootRom version 3.3.0.0.12 or greater is supported. Miscellaneous: Due to changes in the 4.2 switch chip firmware, when upgrading from a previous release it will take up to 8 minutes to update a fully-populated 9120 chassis (or 9240 hemisphere) when upgrading from a 4.1 or 4.0 level of firmware. If there are dual managed spines in a chassis, this release must be placed on both spines as the inactive image. Both spines must then be set to boot into this image. Once complete, reboot both spines. This will be a disruptive reboot. It is recommended to always have both spines running the same version of firmware. 6. Trademarks QLogic, the QLogic logo, QLA, SANbox, SANsurfer, and SANblade are registered trademarks of QLogic Corporation. SANtrack and SAN Express are trademarks of QLogic Corporation. Windows is a registered trademark of Microsoft Corporation. SANavigator is a registered trademark of McData Corporation. Silkworm is a registered trademark of Brocade Communications Systems Inc. All other brand and product names are trademarks or registered trademarks of their respective owners. SilverStorm 9000 4.2.2.0.2 Release Notes 5 of 6

7. Notices Information furnished in this document is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are only for illustrative purposes. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document. 8. Contacting Support Please feel free to contact your QLogic approved reseller or QLogic Technical Support at any phase of integration for assistance. QLogic Technical Support can be reached by the following methods: Web: http://support.qlogic.com North America Contact Information Email: support@qlogic.com Phone: (952) 932-4040 Support contact information for other regions of the world is available at the QLogic website: http://support.qlogic.com Go to Top Copyright 2008. All rights reserved worldwide. QLogic, the QLogic logo, and the Powered by QLogic logo are registered trademarks of QLogic Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners. SilverStorm 9000 4.2.2.0.2 Release Notes 6 of 6