Appendix 1 to the R&Mfreenet Warranty Program

Similar documents
Qualified Partner Programme QPP. Warranty Felice Guarna

Field-testing procedure. LANmark-6

DATWYLER SYSTEM WARRANTY

Psiber Data WireXpert P R O F E S S I O N A L N E T W O R K T E S T I N G & P R O T O C O L A N A L Y S I S

Certification for 10G copper cabling

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4

Design Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6A Shielded Connection Module

LANmark-6 10G LANmark-6 A

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

Tarleton State University. Specifications

The module for the highest standards, guarantees the best performance in the 10 Gigabit Ethernet cabling.

Passive Infrastructure Technical Specification. Version 1 / March 14

PANGEN SYSTEM WARRANTY. Warranty Guide

SECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION

"IL CABLAGGIO IN RAME DI CATEGORIA 6 E LA CERTIFICA SUL CAMPO DEI PARAMETRI TRASMISSIVI FINO A 250 MHZ"

CHAPTER 7 Copper Cable Testing

Chapter 4: Network Access. Introduction to Networks v5.1

Training Offer. Catalogue

The standard for generic cabling

COMMUNICATION & NETWORK DESIGN STANDARD CABLING STANDARDS. Version AUTHOR: Gary Hill, Anatoli Bogajewski

Optical Fiber Premises Standards News & Trends

The six major components of a structured wiring system are:

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

NZQA unit standard version 3 Page 1 of 5. Demonstrate knowledge for telecommunications premises network cablers

The advantages of the 6-connector channel

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

ISO/IEC 11801: (E)

CERTIFICATION PLUS SM

Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361

Application Note. Data Center Standards and Layouts

ANSI/TIA/EIA-568-B Cabling Standard

Telecommunications Structured Cabling Systems

ANSI/TIA/EIA-568-B Cabling Standard

SECTION COMMON WORK RESULTS FOR COMMUNICATIONS

White paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com

COMMON WORK RESULTS FOR COMMUNICATIONS

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

TECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

History of Standards

MT-RJ OPTICAL FIBER SYSTEMS TESTING. Field Testing Made Easy

Open System Architecture Selecting the Right Cable and Connectivity for Your Application

LanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance

DATWYLER SYSTEM WARRANTY

How new testing standards affect you Singapore, Nov 2009

EA15 CALIBRATION PROCEDURE

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m

Copper Riser And Intrabuilding Cabling

The High Cost of a Low-Cost Cable Certification Tester

E-DAT C6A. The compact connection system of course with Cat.6A

Common Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks

Qualified Partner Programme QPP. Fiber Optic Products - The VISIONsystem Felice Guarna

Product information Patch Cord Cat. 5e, U/UTP, 4P, PVC, gray, RJ45/u- RJ45/u, 0.5 m

How to Decide on Optical Fibre Termination Options. Thomas Ko, RCDD Product Manager Tyco Electronics / AMP NetConnect

Multimode Measurement Cords Recommendations for Multimode Link Field Certification

Anixter Standards Reference Guide

Light over PoE. Emanuele Colombo Country Manager R&M Italia October 2017

The Impact of Internet of Things on Cable Certification

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

DATA CABLING - CRAWLING OUT OF THE MELTING POT?

[0.057] 5.8 [0.23]

BACKBONE CABLING. Structured Cabling Systems. Entrance Closet. Telco Closet. Intermediate Cross Connect. Telco Closet. Main Cross Connect.

AMP ACT 1 INSTALLING PREMISES CABLING SYSTEM. Welcome!!! Instructor : Nicholas Yeo

NZQA registered unit standard version 2 Page 1 of 7. Demonstrate basic knowledge of electronic security data protocols and cabling

SCT-MMA / SCT-SMA Fiber Optic Adapters

9/27/04 cci Cablecom Inc. 1

TO THE BID PACKAGE FOR COUNTY OF INYO NETWORK PROJECT. This addendum is being issued to modify portions of the Bid Package for the Project entitled:

DTX-MFM/GFM/SFM. Fluke Networks DTX-GFM Specs. Users Manual. Provided by Fiber Modules

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

The Impact of Internet of Things (IoT) on Cable Certification

SPECIFICATION STANDARD COPPER RISER AND INTRABUILDING CABLING

Fiber Backbone Cabling in Buildings

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Qualified Partner Programme QPP. Voice Integration Felice Guarna

NGEAB-T Use Case ad hoc February 6, 2015

Meeting updated ISO/IEC Your professional partner of structured cabling system

[0.057] 5.8 [0.23]

Wirewerks Datacenters Becoming More Common in Our Workplace, Next Step Solution

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett

Fiber Optic and CAT 5-6 Installer Premise Cabling

The Quality Connection. LEONI QuickLine Class E Cabling Solution

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Cables and Connectors

Cabling Solutions Data Center & Local Area Networks

PIONEERS OF The Structured Cabling Systems

Why you need Fiber and Copper Certification. Presenter: Wayne Allen Role: Technical Manager Fluke Networks

White Paper: Installing Data Networks Using LinkWare Live SaaS

Largest Cat 6A Installation in Midwest Pushes Frontiers of Networking Technology

ANSI/TIA/EIA-568-B A P P E N D I X TECHNICAL INFORMATION. Contents ANSI/TIA/EIA-568-B. anixter.com

SMVector EtherNet/IP Communication Module Communications Interface Reference Guide

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.

Transcription:

Appendix 1 to the R&Mfreenet Warranty Program 1 R&M Certification Process The R&Mfreenet certification process is three pillars: a) Adherence to applicable standards, both for products and installations; b) - Installation performed according to the R&M instruction manual; - and R&M Installation and Test Specifications for Generic Cabling ; c) Visual inspection and test results showing no failures. Point a) Point b) Point c) See standards - See R&M Installation and Test Specifications for Generic Cabling - See R&M instruction manual Visual inspection on 10% of installed links (5% on patch panel and 5% on outlet) for: Termination according to instruction manual Bending radius according to R&M Installation and Test Specifications for Generic Cabling Cable jacket stripping and untwisting of cable pairs according to EN 50174 and R&M Installation and Test Specifications for Generic Cabling Labeling of components according to EN 50174 Cable laying, management, grounding connection according to EN 50174 and R&M Installation and Test Specifications for Generic Cabling 100% of links fulfill the applicable/guaranteed limits according to 2 standards. The fiber optic measurement must be made with a Power Meter / Light Source according to ISO/IEC 11801 and R&M Test Procedures. Back-scattering measurements (OTDR) are used to check components and to locate errors. In special cases OTDR measurements can be recognized as performance measurements. 1.1 Administrative process for warranty A complete R&M certification process package is required, consisting of: Cabling plans in AutoCad, PDF, RTF format; Worksheet describing material used, where it was used and labeling etc. in DOC, PDF format; Power budget at 850 ηm/1300 ηm or 1310 ηm/1550 ηm including fiber length, number of connectors and number of splices. Complete test report showing all autotest electrical parameters and/or optical parameters (original test equipment measurement data only), and bi-directional measurements. Appendix Warranty_e_1_8.doc Page 1 / 5

2 Standards 2.1 ISO/IEC and EN ISO/IEC 11801 2nd Edition : Sept. 2002 (Class D2002 / E) EN 50173-1 : Nov. 2002 (Class D2002 / E) EN 50174 : 2000 2.2 TIA/EIA-568-B TIA/EIA-568-B.2 : April 2001 (Cat.5e = Class D2002) TIA/EIA-568-B.2-1 : June 2001 (Cat.6 = Class E) TIA/EIA-568-B.3 : April 2000 2.3 IEEE 802.3an 10GBASE-T R&M guarantees, that the transmission characteristics of the channel will comply with the IEEE 802.3an 10GBASE-T : Channels composed of R&M Cat. 6 UTP components and installed and tested according to R&M guidelines will reach 55m according to the current standards. Channels composed of R&M Real10 Cat. 6 components and installed and tested according to R&M guidelines will reach 100m according to the current standards. R&M reserves the right to revise this statement in case of adjustments to the standard. 3 Approved Test Equipment 3.1 Copper (Level III & IV Measurement Accuracy) A certified party must calibrate any test equipment at least once a year. Class D 2002 / E Fluke DSP 4000 Series Fluke DTX Series Microtest Omni II Wire Scope 350 LANTEK 6 und 7 Wavetek LT 8600 3.2 Fiber Optic (FO) All commercially available test equipment complying with the measurement procedure IEC 60874 or similar are admissible. A certified party must calibrate any test equipment at least once a year. Appendix Warranty_e_1_8.doc Page 2 / 5

4 Guaranteed topologies Permanent link or channel without CP, two-connector model (Model no. 1); Permanent link or channel with cross connect, three-connector model (Model no. 2); Fixed horizontal cable or permanent link or channel with CP, three-connector model (Model no. 3); Fixed horizontal cable or permanent link or channel with cross connect and CP, fourconnector model (Model no. 4); Direct combined channel (Model no. 5); Spliced combined channel (Model no. 6); Patched combined channel (Model no. 7); R&M CLASSICsystem Class D 2002 R&M STARsystem* Class E Model 1 Model 2 Model 3 Model 4 Model 5 Model 6 Model 7 R&M VISIONsystem** Fiber Optic * We only give a Class E warranty, if all components in the link are Category 6 or better (R&M STARsystem components). ** In fiber optic systems the following must be considered: An increased number of splices and/or connections in a channel can result in length restrictions for the compensation of the additional attenuation. 4.1 Copper topologies Model 1 Appendix Warranty_e_1_8.doc Page 3 / 5

Model 2 Model 3 Model 4 Appendix Warranty_e_1_8.doc Page 4 / 5

4.2 Fiber Optic Topologies Model 5 Model 6 Model 7 EQP = Equipment BD = Building Distributor FD = Floor Distributor CP = Consolidation Point TO= Telecommunication Outlet TE = Terminal Equipment Appendix Warranty_e_1_8.doc Page 5 / 5