Plasma Low Temperature Sterilization. With vaporized hydrogen peroxide. PlazMax Line

Similar documents
THE STERRAD NX SYSTEM with ALLClear Technology JUST LOAD AND GO MM/DD/YY. System Ready Back 09:00:00 AM. Select Cycle To Begin: Start ADVANCED Cycle

JUST LOAD AND GO. THE STERRAD 100NX SYSTEM with ALLClear Technology. Productive Reduces workflow interruptions

JUST LOAD AND GO. THE STERRAD 100NX SYSTEM with ALLClear Technology. Productive Reduces workflow interruptions

Trans Smart series Steam sterilizers

WITH SAFETY FROM A SINGLE SOURCE.

Sterilisation trays and baskets

18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION

ulrich medical Tourniquets

A smart system with an easy touch APC SmartTouch. Airborne Particle Counter

Site Planning and Installation Guide

KARL STORZ AIDA. Advanced Image and Data Acquisition. Exceptional documentation. Record. Edit. Checklist. Complete. Patient.

CONTINUING A TRADITION OF PROVEN TECHNOLOGY

Model KB 400 Cooling incubators with compressor technology

Med-Info. Council Directive 93/42/EEC on medical devices. TÜV SÜD Product Service GmbH

STERILE CONTAINER SYSTEMS ACCESSORIES

ulrich medical Tourniquets

REFERENCE GENERATOR FOR CALIBRATION OF HUMIDITY AND TEMPERATURE INSTRUMENTS

C2 NerveMonitor Intraoperative Neuromonitoring

ulrich medical Tourniquets

Model KB 400 Cooling incubators with compressor technology

Model VDL 115 Vacuum drying chambers for flammable solvents

Model KB 400 Cooling incubators with compressor technology

Model KB 240 Cooling incubators with compressor technology

Model KT 53 Cooling incubators with thermoelectric cooling

STERILE CONTAINER SYSTEMS ACCESSORIES

Med-Info. Council Directive 93/42/EEC on Medical Devices. TÜV SÜD Product Service GmbH

See more with the NEW testo 880 thermal imager

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

Med-Info. Council Directive 93/42/EEC on medical devices. TÜV SÜD Product Service GmbH

Enhanced insulation thickness. Environment friendly polyurethane foam, water based foaming.

Brillant 285 WET ABRASIVE CUT-OFF MACHINES

WM-60 MOBILE WORKSTATION

Minicen Microcen 24 Biocen 22 Biocen 22 R. About centrifugation

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KT 53 Cooling incubators with thermoelectric cooling

ValiPak / ValiPak TOUCH. The validatable ValiPak and ValiPakTOUCH bar sealers for The packaging of pouches and reels.

Rotator PTR-60. Operating instructions. For version V.2GY

EXCLUSIVE. Validated for chemical/ biological hazards* egross pro-x. Simply the most innovative, safe grossing workstation MILESTONE

Micro calibration bath Models CTB , CTB

Microplate shaker PMS-1000i

Product Guide. Repeatable RH and temperature measurement for precise humidity control and validation

Rocker PMR-30. Operating instructions. For version V.2GW

INSTRUCTIONS FOR USE. RECHARGEABLE System for Hearing Aids

EKOHEAT Induction Heating Systems

Operating Instructions for Digital Thermometers. Model: DTM

Symbols Glossary Rev. 1 1 / 16

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Drying and heating chambers. Series ED FD FED FP M

BENCHMIKE PRO NEW. The Industry s leading off-line ID/OD/Wall measurement system

Datasheet Thermal imager

The Economical Choice of Balance for Routine Weighing Applications

testo 875 and testo 881 for professional building thermography

Consolidated Sterilizer Systems Designed to Transform Your Laboratory

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

Model VD 23 Vacuum drying chambers for non-flammable solvents

lectronic FasTest s ETS ool ystem Eliminate the mess Ultimate seal control Serial, Ethernet or DeviceNet

Standard Operating Procedure for the Kaye Validator AVS System

Temperature Data Logger EBI 100

Designed to make your job easier MSA 2.0 and MSA 2.1 Electrofusion Units

Immunity: EN capacity 75 µl Capillaries. 1,5 x 75 mm. Rotor and Lid as evaluation disc incl. Cat.-No. capillaries per rotor

A 2 O Advanced Automated Osmometer

5 AXIS CNC WELD PREPARATION MACHINE HIGH-PERFORMANCE CNC PLASMA CUTTING

Brighten The World With

DEPENDABLE BY DESIGN EASE OF USE PERFORMANCE SERVICEABILITY DURABILITY

Temperature/Humidity, Vibration Chambers

Spraybase Technical Specifications Sheet

Mobile Video Cystoscopy from KARL STORZ

DEN-1 Densitometer Suspension turbidity detector

MEASURING AND TESTING INSTRUMENTS

The Autopol VI Automatic Polarimeter

BENCHMIKE PRO NEW. The Industry s leading off-line diameter & ovality measurement system

Quality Electrochemical Analysis Professional Meters Basic Meters Sensors

-bio. Rocker PMR-30. Operating instructions

Temperature dry-well calibrator Models CTD , CTD

1. Safety Precautions

Tiny sample. Huge insights. Eurolyser Point-of-Care Systems

Sprint Cleanroom Door

OPERATING INSTRUCTIONS

Aged Care Security Solutions. security.gallagher.com

TSI AEROTRAK REMOTE WITH PUMP PARTICLE COUNTERS INSTALLATION CONSIDERATIONS

SAFE, FLEXIBLE, EASY CURRENT TRANSFORMER CURRENT TRANSFORMERS FOR THE SAFE MEASUREMENT OF HIGH CURRENTS

Sorvall BP 8 and 16 Blood Banking Centrifuges

Infrared temperature measuring instrument

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

Modular CLEANROOM Solutions

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

Disposable Glassware CO R N I N G A N D P Y R E X D I S P O S A B L E G L A S SWA R E D I G I TA L ST I R R I N G H OT P L AT E S...

PR3400 Series 1.4Mp USB Cameras Hardware Guide

PalmScan PRO 5 in 1 Biometer Your Complete Biometry System - Fully Configurable

ALL-IN-ONE TMJ Arthroscope

C2 NerveMonitor Intraoperative Neuromonitoring

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

MEDICAL CONNECTIVITY SOLUTIONS THE THE RELIABLE EXPERT

4K Displays New and Updated Products

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Cisa Serie 640 SO. Sterilization Units

Outstanding range of leads The machine for demanding wires Excellent stripping quality High productivity

Wolf Laboratories Limited

V

Instrument Head for HEINE UniSpec Tubes. HEINE UniSpec Disposable Tubes

Transcription:

Plasma Low Temperature Sterilization With vaporized hydrogen peroxide

Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax provides an efficient sterilization solution for heat & moisture sensitive equipment in CSSDs and Gastroenterology & Respiratory Endoscopy Clinics. With PlazMax you get increased productivity, reduced risk of work stoppage, and efficient supply of sterilized equipment where it s needed. In operating rooms PlazMax benefits you with almost immediate access to sterilized equipment. Simple to install and control, only requiring 1-phase electricity and Hydrogen Peroxide (H 2 O 2 ) packs to operate. No need to send equipment to a CSSD, eliminating the risk of damage and contamination in transit. 2

Advanced and Flexible Control System Take Advantage of Tuttnauer s state-of-the-art control system with multicolor touch screen display. Includes equipment tracking and maintenance notification features. Stainless Steel Machine Housing Built with robust stainless steel panels that will not discolor or break like plastic alternatives. Wide Range of Chambers Don t over pay for two small sterilizers when you can buy one large sterilizer. Choose from 4 models with chamber sizes from 47 to 162 liters. Keep Running Costs Low Keep you consumable costs low With PlazMax you have the freedom to use commonly available market accessories such as indicators, pouches & rolls, etc. that are suitable for sterilization with vaporized hydrogen peroxide. Tuttnauer also sells sterilant, and biological indicators & chemical indicators. Clean Technology Non-toxic sterilizing agent Minimal utility requirements low electricity consumption, no water consumption The sterilization process results in water and oxygen by-products Vertical Sliding Door Automatic Vertical Sliding Door with built-in foot operated device for hands-free door operation. Tough Challenges PCD By challenging the PlazMax sterilizer with our Process Challenge Device (optional) you will be confident that it does its job at the highest sterilization levels. 3

PlazMax P50 180mm 624mm 420mm 47Liter Chamber Door options Single Double Manual Vertical Automatic with Hands-Free door operation Technical Specifications Model Chamber Volume External Dimensions (WxHxD/D 2-doors) mm No. of Baskets (WxD cm) Power (W) Current (A) Voltage (V) 1-Phase 50-60 Hz P50 47 702 x 1528 x 729 / 736 1 (40X60 cm) 3100 W 13.5 A 230 V P110 110 702 x 1768 x 729 / 736 2 (40x60 cm) 4300 W 18.7 A 230 V P160 162 702 x 1768 x 1029 / 1036 2 (40x90 cm) 4300 W 18.7 A 230 V 4

PlazMax P110 420mm 624mm 110Liter Chamber 420mm PlazMax P160 420mm 162Liter Chamber 420mm 924mm Door options for P100 and P160 Single Double Manual Vertical Automatic with Hands-Free door operation * Internal Chamber dimensions for each model are specified next to the image for each chamber 5

Advanced Control System for Your CSSD Take advantage of Tuttnauer s sophisticated user-friendly control system for repeatable high performance. Standard Features 7 Multi-color touch screen panel (also on second door of two door configurations) Stores the last 200 cycles in built-in memory Multiple access levels and user passwords to control access/ operation of the Plazmax Diagnostic In/Out test (enables technician to check each system component separately) Sterilization Temperature range 50 C to 55 C Thermal Printer USB and Ethernet connection port Sophisticated Touch Screen HMI The HMI (Human Machine Interface) has been designed with the following considerations: Multi-color display for easier reading from a distance Multilingual (26 languages) Dynamic graph displaying the chamber pressure and the cycle process Displays process info pressure, temperature, vaporizer temp. Equipment Tracking & Maintenance Notification Equipment tracking software provides a detailed sterilization history of each endoscope tracked. The software will notify when equipment needs to be returned back to the original equipment manufacturer for maintenance. Handle Endoscopes ID Name Max Current Total Last Init 1 BF 1 T 160 70 10 100 2/SEP/2013 2 BF 160 70 15 150 2/SEP/2013 3 CF Q 160 AL 100 12 224 2/SEP/2013 4 CF 2 T 160 L 70 18 321 2/SEP/2013 5 PCF 160 AL 100 10 154 2/SEP/2013 6 GIF Q 160 70 15 117 2/SEP/2013 7 GIF XP 160 100 10 258 2/SEP/2013 8 GIF PQ 20 70 13 132 2/SEP/2013 SELECT INIT REMOVE NEW... Not Ready 09:31:32 6 th October, 2013 6

R.PC.R Software Automatic Recording of Cycle Information to Your PC Reporting You Can Rely On Automatic recording of cycle information to any PC on your network Convenient access to graphs and tables that are easy to understand Easily generate PDF reports No need to file printouts, saving you time Be in Control with Real-Time Remote Monitoring See the real-time autoclave display on your PC Monitor all activity for up to 8 sterilizers With R.PC.R you can see: Graphs of the cycle data, Numeric cycle data, cycle print-outs, measured values table, parameter table. Software and Hardware Standard Direct network access for technical Support (requires R.PC.R) Touch screen Thermal Printer Optional Remote network access for technical Support (requires R.PC.R) (requires local SIM card for Internet connection) R.PC.R software for access from PC or network USB Digital Cycle Data Connect a USB memory device to the PlazMax and you can download a soft copy of cycle printouts and all cycle data history stored in the sterilizer s memory. 7

Sterilization Cycle Process Sterilization Cycle and Test Programs Model Normal Cycle (Non-hollow loads) Advanced Cycle (Hollow loads) Endoscope * Cycle Time (min.) Cycle Time (min.) Cycle Time (min.) P50 35 40 28 P110 45 50 30 P160 50 55 45 * Endoscope cycle temperature: short heating time and reduced H 2 O 2 exposure time. Note: Cycle times are based on a hot cycle and may vary according to load volume. Test Cycles Test I Test II Description Penetration Test Leakage Test 8

How can you be sure your hollow instruments have been 100% penetrated? Use Tuttnauer s Process Challenge Device (PCD) Tuttnauer s PCD kit includes lumens that are more difficult to penetrate than your loads. With the PCD you can be certain your lumen loads, like endoscopes, are fully exposed to the vaporized hydrogen peroxide sterilizing agent. The PCD kit includes long lumen configurations that cannot be successfully sterilized in many competing devices. The PCD Kit includes 1mm diameter lumens with lengths of 4m (both sides open) and 1.4m lumens (one side open). 1.4m one side open 4m both sides open Chemical indicators are used every cycle and in each packed item to validate penetration and to ensure vaporized peroxide has made contact with the load. Biological indicators are used according to a schedule required by a hospital s policy and require an incubator (optional) to facilitate the detection of micro-organisms. Biological indicators validate sterilization by helping determine that the sterilizer effectively kills the micro-organisms. Safety Features Tuttnauer strives to provide sterilizers that ensure safety for patients, staff, and the environment. Safety features include: No hazardous or odorous emissions Low temperature and low pressure during sterilization Door is locked during cycle operation 9

Non-Hollow Loads Non-hollow loads are sterilized with the Normal Cycle. Electrocautery Instruments Dopplers Laser probe Thermometer Ophthalmic lenses Harmonic cable Defibrillator paddles Hollow Loads Hollow loads are sterilized with the Advanced Cycle. Laryngscope blade Shaver hand pieces Surgical power drill Laryngscope & blades Fiber optic light cable The instruments and equipment presented are only a partial list of the wide range that can be safely sterilized in PlazMax Only use PlazMax with equipment authorized by original manufacturer to be sterilized with plasma sterilizers. 10

Endoscopes Endoscopes and similar equipment are sterilized with the Endoscope Cycle. Rigid scope for optics Rigid scope Flexible endoscope Flexible endoscope 11

Standards and Directives PlazMax has been developed according to the following international standards and directives (partial list): ISO 9001:2008 ISO 13485:2003 ISO 14937 EN 61010-2-040:2005 EN 60601-1:2006/AC:2010 Medical Device Directive 93/42/EC CE Medical Device Mark 0344 Your Sterilization & Infection Control Partners Company Profile For over 90 years, Tuttnauer s sterilization and infection control products have been trusted by hospitals, universities, research institutes, clinics and laboratories throughout the world. Supplying a range of top-quality products to over 100 countries, Tuttnauer has earned global recognition as a leader in sterilization and infection control. Global Partnership At Tuttnauer we feel that business means people dealing with people. We pride ourselves on our reputation for having long-lasting relationships with our customers based on commitment and trust, spanning over decades and distances. Our Flexibility is Your Advantage Beyond our wide range of products and ability to customize products to customer requirements, we also manage complete turnkey solutions, including planning, design and installation of equipment, as well as consultation and feasibility studies, for projects of all sizes. YEARS 1925-2015 International Sales and Marketing E-mail: info@tuttnauer-hq.com www.tuttnauer.com Tuttnauer Europe b.v. Hoeksteen 11, 4815 PR P.O.B. 7191, 4800 GD Breda The Netherlands Tel: +31 (0) 765 423 510, Fax: +31 (0) 765 423 540 E-mail: info@tuttnauer.nl Tuttnauer USA Co. 25 Power Drive, Hauppauge, NY 11788 Tel: +800 624 5836, +631 737 4850 Fax: +631 737 0720 E-mail: info@tuttnauer.com Distributed by: LTR330-0061/PLASMAX/V-7/06.18