Network Control Engine Catalog Page

Similar documents
Network Control Engine

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface

Network Integration Engine (NIEx9) for Third-Party Integrations Catalog Page

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Application and Data Server (ADS) Lite-A System Catalog Page

NIE59 Network Integration Engine Figure 1: NIE59 Network Integration Engine

NAE. Metasys. BAS network automation Supervisory controllers. Network Automation Engine

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE Software Release 8.1 Issued February 2017

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued June 2018

Input/Output Module (IOM) Series Catalog Page

LN Series Remote Input/Output (I/O) Modules

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, MS-NAE551S-2, NAE Software Release 9.0 Issued August 2017

Advanced Application Field Equipment Controller (FAC) Catalog Page

Field Equipment Controller (FEC) Series Catalog Page Code No. LIT Issued June 2018

Network Integration Engine Product Bulletin

Network Automation Engine

Network Integration Engine

Network Integration Engine (NIEx9) for Third-Party Integrations Product Bulletin

FEC - FAC. Metasys controllers. Complex BAS Programmable controllers. Catalog Page. Field Equipment Controllers

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued December 2017

FX-PCA Advanced Application Programmable Controller Catalog Page

NCE25 Installation Instructions MS-NCE25xx-x

NIE39/NIE49 Installation Instructions MS-NIE39xx-2, MS-NIE49xx-2

Smart Equipment Controls (SEC)

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3, MS-NAE5510-2U

FX40 Supervisory Controller

NAE55/NIE55 Installation Instructions MS-NAE55xx-3, MS-NIE55xx-3

FX Input/Output (I/O) Modules XM07 and XM14

FX14 Field Controller

PEAK TM. SMART Equipment Controllers. Product bulletin

Metasys N1 Network Integration

LCS85 Product Bulletin

Application. NAE55 Installation Instructions * S* Installation. Parts included. Materials and special tools needed

LX Series Remote Input/Output (I/O) Controller

FX-BTCVT Bluetooth Commissioning Converter Installation Instructions

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

VMA Programmable VAV Box Controllers Catalog Page Code No. LIT Issued February 2018

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

FXVMA Variable Air Volume (VAV) Box Controller

Medium User Interface (MUI) Version 3

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

TC-9102 Terminal Controller

VMA Programmable VAV Box Controllers Catalog Page

FEC26 Field Equipment Controller

FX06 Field Controller

Verasys System Product Bulletin

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

TEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications

TALON Network Manager- 2 & 6 Express

DX-9100 Digital Controller, Version 2

QUICK START GUIDE M2000 SERIES rue Charles, Suite 100, Mirabel, QC, J7J 1X9

FEC26 Extended Temperature Field Equipment Controller

LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules

System 450 Series Expansion Modules with Relay Outputs Installation Instructions

FEC25 Field Equipment Controller Installation Instructions Part No , Rev. A Issued April 2016

IOM47 Input/Output Module Installation Instructions Part No , Rev. L Issued November 2017

IOM47 Input/Output Module Installation Instructions Part No , Rev. K Issued April 2016

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Extended Digital Controller

FX-PC Series Programmable Controllers and Related Products Product Bulletin

IOM2721 Input/Output Module Installation Instructions MS-IOM2721

HARDWARE GUIDE. Boiler Controller M2000 Series. Specifications and Operational Guide

FEC26 Field Equipment Controllers Installation Instructions MS-FEC2611-x, MS-FEC2621-x, MS-FEC2611-xET

N2 Dialer Module. Features and Benefits

FEC1611 and FEC1621 Field Equipment Controller Installation Instructions

Field selectable application type and room module series, via dip-switches on controller

FAC Advanced Application Field Equipment Controller Installation Instructions

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

FX-PCA3611 Advanced Application Programmable Controller Installation Instructions

TC Compact Series for BACnet Networks

DS December Omni BEMS Controller

FX-DIS Local Controller Display Technical Bulletin

VMA1610 and VMA1620 Variable Air Volume Controllers Installation Instructions

Metasys System Field Equipment Controllers and Related Products Product Bulletin

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

LCS85 Turnkey User's Guide Part No , Rev. F Software Release 6.1 Issued June 17, 2013 Supersedes January 30, 2011

Web server. Simplified.

FX80 Supervisory Controller Catalog Page Code No. LIT Issued July 2018

XT-9100 Technical Bulletin

Priva Blue ID Digital input module DI4/DI8/DI16

LN Series Communicating Sensors

Commercial Comfort System (CCS)

FX Supervisory Controller Wireless TEC Option Card Installation Instructions

TC Modular Series for BACnet Networks

TC Compact Series for BACnet Networks

DS October MAXIM 1010 Controller

Metasys System Configuration Tool (SCT)

TC Compact Series Unitary Equipment Controller

rcc.1081 Installation Instructions

Modular Room Control (MRC) Series Expansion Board

clarity 3 Programmable Controller

Web server. Simplified.

Priva Blue ID Communication module RS485 SC44

FX-PCA Advanced Application Programmable Controller Installation Instructions

BACnet. b3810 Series Local Controllers

BACnet. b3867 Terminal Controllers

Transcription:

MS-NCE25xx-x Johnson Controls www.johnsoncontrols.com LIT-1900455 2018-12-17 Release 9.0.7

Introduction The Metasys Network Control Engine (NCE) Series controllers provide a cost-effective solution designed for integrating central plants and large built-up air handlers into your existing Metasys networks. These network control engines combine the network supervisor capabilities and IP network connectivity of a Network Automation Engine (NAE) with the I/O point connectivity and direct digital control capabilities of a Field Equipment Controller (FEC), making them the ideal choice for expanding and improving your Metasys installation for greater data visibility and control over your energy usage. NCEs provide supervisory control of a specified field bus trunk with up to 32 field controllers. NCE25 Series controllers provide integration to many network protocols, including BACnet /IP, BACnet MS/TP, N2 Bus, Modbus RTU, Modbus TCP, M-Bus (EN 13757-3), KNX IP, and other third-party protocols. The MS-NCE2500-0 and MS-NCE2506-0 models, which are available in Europe only, do not provide a physical field controller trunk connection. All NCE models feature 33 integral I/O points and a Sensor/Actuator (SA) Bus, which allow you to increase the NCE's I/O field point capacity and integrate NS Series Network Sensors, and VFDs into your NCE application. Some NCE models feature an integral field controller display screen with a navigation keypad, allowing for easy modifications in the field. Application documentation Refer to the Network Engines Product Bulletin (LIT-12012138) for important product application information. Repair information If the network engine fails to operate within its specifications, replace the unit. For a replacement network engine, contact the nearest Johnson Controls representative. Features and benefits Use of commonly accepted IT standards at the automation and enterprise level Allows you to install the network engine on the existing IT infrastructure within a building or enterprise and use standard IT communication services over the company intranet, WAN, or public Internet with firewall protection. Communication between the network engine and clients is encrypted with Hypertext Transfer Protocol Secure (https). Web-based user interface Allows you to access, monitor, and control the network engine from a supported web browser connected to the network. Secure Linux operating system Provides a high level of protection from threats with the adoption of the Linux operating system, a full replacement of the recently expired Windows CE operating system. Supervision of controller networks including Johnson Controls and third-party protocol devices Supports connectivity to open network standards for complete flexibility in the selection of field devices. Supported protocols are model and software release dependent. They include BACnet MS/TP, BACnet/IP, N2 Bus, Modbus RTU, Modbus TCP, M-Bus (EN 13757-3), KNX IP, and other third-party protocols. Prior to Metasys system Release 9.0.7, only the Network 3

Integration Engines (NIE29s) provided the Modbus, M-Bus, and KNX integrations. At Release 9.0.7, these third-party integrations are included with all NCEs. Multiple connection options for data access Allow connection of a web browser through the IP network using the Ethernet port. At Release 9.0 or earlier, you can use the optional internal or external modem for a dial-up connection. Modem functions are not available for an NCE25 at Release 9.0.7. Integral field controller with 33 I/O points Provides field-level control of central plant and large air-handler applications combined with enterprise level IP network connectivity. Expandable I/O point capacity, NS sensor connectivity, and VFD control on field controller SA Bus Allow you to connect multiple IOMs, NS Series Network Sensors, and VFDs to the field controller SA Bus, which greatly expands the network engine's field level control capabilities. No hardware to replace Upgrade from Windows CE to Linux OS using a simple network download. Point type counts Table 1: Point type counts Point type Signals accepted Count Universal input Binary input Configurable output Analog output Analog Input, Voltage Mode, 0 10 VDC Analog Input, Current Mode, 4 20 ma Analog Input, Resistive Mode, 0 2k ohm, RTD (1k [Johnson Controls], 1k PT, A99B SI), NTC (10k Type L, 2.252k Type 2) Binary Input, Dry Contact Maintained Mode Dry Contact Maintained Mode Pulse Counter/ Accumulator Mode (High Speed), 100Hz Analog Output, Voltage Mode, 0 10 VDC Binary Output Mode, 24 VAC Triac Analog Output, Voltage Mode, 0 10 VDC Analog Output, Current Mode 4 20 ma Binary output 24 VAC Triac 7 Ordering information Contact the nearest Johnson Controls representative to order an NCE25 or accessories. Specify the desired product code number using the following NCE ordering information tables. 10 8 4 4 4

Table 2: NCE25 Ordering Information (Releases 9.0 and 9.0.7 Only) Product code number MS-NCE25xx-x (Base Features on Each NCE25) MS-NCE2500-0 (Europe only) MS-NCE2506-0 (Europe only) Release N/A Description Each NCE25 Series model requires a 24 VAC power supply and includes one RS-232-C serial port, one RS-485 optically isolated SA Bus port, one USB serial port, one Ethernet port, and an MS- BAT1020-0 Data Protection Battery. Each NCE25 Series model has 33 integral I/O points and supports up to 128 additional I/O points on the SA Bus. Supports BACnet IP network. 9.0.7 Base features with no physical field controller trunk connection. 9.0.7 Base features with no physical field controller trunk connection. Includes integral display screen. MS-NCE2510-0 9.0.7 Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and one N2 Bus. The number of supported devices on the third-party trunk depends on the protocol. For the N2 Bus, up to 32 devices are supported. MS-NCE2511-0 9.0.7 Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and one N2 Bus. The number of supported devices on the third-party trunk depends on the protocol. For the N2 Bus, up to 32 devices are supported. Includes internal modem. Note: Modem functions are no longer available after this engine is updated with Metasys Release 9.0.7 or later. MS-NCE2516-0 9.0.7 Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and one N2 Bus. The number of supported devices on the third-party trunk depends on the protocol. For the N2 Bus, up to 32 devices are supported. Includes integral display screen. MS-NCE2517-0 9.0.7 Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and one N2 Bus. The number of supported devices on the third-party trunk depends on the protocol. For the N2 Bus, up to 32 devices are supported. Includes integral display screen and internal modem. Note: Modem functions are no longer available after this engine is updated with Metasys Release 9.0.7 or later. MS-NCE2520-0 9.0 Supports one LonWorks trunk with up to 32 LonWorks devices. MS-NCE2521-0 9.0 Supports one LonWorks trunk with up to 32 LonWorks devices. Includes internal modem. MS-NCE2526-0 9.0 Supports one LonWorks trunk with up to 32 LonWorks devices. Includes integral display screen. MS-NCE2527-0 9.0 Supports one LonWorks trunk with up to 32 LonWorks devices. Includes integral display screen and internal modem. MS-NCE2560-0 9.0.7 Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and one MS/TP Bus. The number of supported devices on the third-party trunk depends on the protocol. For the MS/TP bus, up to 32 devices are supported. 5

Table 2: NCE25 Ordering Information (Releases 9.0 and 9.0.7 Only) Product code number Release Description MS-NCE2561-0 9.0.7 Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and one MS/TP Bus. The number of supported devices on the third-party trunk depends on the protocol. For the MS/TP bus, up to 32 devices are supported. Includes internal modem. Note: Modem functions are no longer available after this engine is updated with Metasys Release 9.0.7 or later. MS-NCE2566-0 9.0.7 Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and one MS/TP Bus. The number of supported devices on the third-party trunk depends on the protocol. For the MS/TP bus, up to 32 devices are supported. Includes integral display screen. MS-NCE2567-0 9.0.7 Supports two third-party trunks (Modbus RTU or TCP, M-Bus, or KNX) and one MS/TP Bus. The number of supported devices on the third-party trunk depends on the protocol. For the MS/TP bus, up to 32 devices are supported. Includes integral display screen and internal modem. Note: Modem functions are no longer available after this engine is updated with Metasys Release 9.0.7 or later. Table 3: NCE25 accessories ordering information Product Code Number MS-BAT1020-0 TL-MAP1810-xx MS-DIS1710-0 AS-XFR100-1 AS-XFR010-1 MS-EXPORT-0 Description Replacement data protection battery for the NCE25. Rechargeable NiMH battery: 3.6 V 500 mah, with a typical life of 5 to 7 years at 21 C (70 F) Pocket-sized web server that provides a wireless mobile user interface to Metasys field controllers, thermostats, and smart rooftop units. Refer to the Mobile Access Portal Gateway Catalog Page (LIT-1900869) to identify the appropriate product for your region. Local Controller Display connects to NCE on SA Bus and provides menu display and navigation keypad for monitoring status and controlling parameters on the NCE s integral field controller. Note: A DIS1710 display does not operate on NCE models that have an integral controller display. Power transformer (Class 2, 24 VAC, 92 VA maximum output), with enclosure Power transformer (Class 2, 24 VAC, 92 VA maximum output), no enclosure Metasys Export Utility, which extracts historical trend, alarm, and audit data from the system and presents the historical data in a variety of formats. Note: This option is not necessary for sites that have an ADS/ ADX as the Site Director because it is provided with the ADS/ADX solution. 6

Technical specifications Table 4: NCE25 Power Requirement Power Consumption Power Source Ambient Operating Conditions Ambient Storage Conditions Data Protection Battery Processors Memory Dedicated nominal 24 VAC, Class 2 power supply (North America), SELV power supply (Europe), at 50/60 Hz (20 VAC minimum to 30 VAC maximum) 25 VA maximum for NCE25 only Note: The 25 VA rating does not include any power supplied by the NCE to devices connected at the NCE BOs. BO devices connected to and powered by an NCE can require an additional 125 VA (maximum). +15 VDC power source terminals provide 100 ma total current; quantity of inputs: five, located in Universal IN terminals; for active (3-wire) input devices 0 C to 50 C (32 F to 122 F), 10 to 90% RH, 30 C (86 F) maximum dew point -40 C to 70 C (-40 F to 158 F), 5% to 95% RH, 30 C (86 F) maximum dew point Supports data protection on power failure. Rechargeable NiMH battery: 3.6 VDC 500 mah, with a typical life of 5 to 7 years at 21 C (70 F); Product Code Number: MS-BAT1020-0 Supervisory Controller: 192 MHz Renesas SH4 7760 RISC processor Field Controller: 20 MHz Renesas H8S2398 processor Supervisory Controller: 128 MB flash nonvolatile memory for operating system, configuration data, and operations data storage and backup and 128 MB SDRAM for operations data dynamic memory Field Controller: 1 MB flash memory and 1 MB RAM Operating System Microsoft Windows Embedded CE 6.0 (Release 9.0) Buildroot 2017.08.2 with Linux kernel 14.4 (Release 9.0.7) 7

Table 4: NCE25 Network and Serial Interfaces (Depending on the NCE model.) Analog Input/Analog Output Point Resolution Input/Output Capabilities Dimensions (Height x Width x Depth) Housing One Ethernet port; 10/100 Mbps; 8-pin RJ-45 connector One optically isolated RS-485 SA Bus port; with a pluggable and keyed 4-position terminal block (on all NCE25 models) One optically isolated RS-485 port; with a pluggable and keyed 4- position terminal block (only on NCE25 models that support an N2 Bus or MS/TP bus trunk) One LonWorks port; FTT10 78 Kbps; pluggable, keyed 3-position terminal block (only on NCE25 models that support a LonWorks Network trunk). The LonWorks models are supported to run the Metasys Release 9.0 software, but not the Release 9.0.7 update. One RS-232-C serial port with a standard 9-pin sub-d connector that supports standard baud rates One USB serial port with a standard USB connector that supports an optional, user-supplied external modem. Modem functions are available with Metasys Release 9.0, but are not available after the NCE is updated with Release 9.0.7. Option: One telephone port for the internal modem; up to 56 Kbps; 6-pin modular connector (NCE models with an optional internal modem have one RS-232-C serial port only; not supported for an engine with Release 9.0.7). Analog Input Points: 16-bit resolution Analog Output Points: 16-bit resolution and ±200 mv accuracy on 0-10 VDC applications 10-Universal Inputs: Defined as 0 10 VDC, 4 20 ma, 0 600k ohm, or Binary Dry Contact 8-Binary Inputs: Defined as Dry Contact Maintained or Pulse/ Accumulator Mode 4-Analog Outputs: Defined as 0 10 VDC or 4 20 ma 7-Binary Outputs: Defined as 24 VAC Triac (selectable internal or external source power) 4-Configurable Outputs: Defined as 0 10 VDC or 24 VAC Triac BO 155 mm x 270 mm x 64 mm (6.1 in. x 10.6 in. x 2.5 in.), minimum mounting space required: 250 mm x 370 mm x 110 mm (9.8 in. x 14.6 in. x 4.3 in.) Plastic housing Plastic material: ABS and polycarbonate Protection: IP20 (IEC60529) Mounting On a flat surface with screws, on three mounting clips, or a single 35 mm DIN rail Shipping Weight Compliance 1.2 kg (2.7 lb) United States: UL Listed, File E107041, CCN PAZX, UL 916, Energy Management Equipment; FCC Compliant to CFR47, Part 15, Subpart B, Class A Canada: UL Listed, File E107041, CCN PAZX7, CAN/CSA C22.2 No. 205, Signal Equipment Industry Canada Compliant, ICES-003 8

Table 4: NCE25 Europe: CE Mark - Johnson Controls declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive. Australia and New Zealand: RCM Mark, Australia/NZ Emissions Compliant BACnet International: BTL 135-2010 Listed B-BC at Metasys system Release 8.1 The performance specifications are nominal and conform to acceptable industry standard. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. North American emissions compliance Canada This Class (A) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la Classe (A) respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. United States This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference, in which case the users will be required to correct the interference at their own expense. Points of single contact APAC Europe NA/SA JOHNSON CONTROLS C/O CONTROLS PRODUCT MANAGEMENT NO. 32 CHANGJIJANG RD NEW DISTRICT WUXI JIANGSU PROVINCE 214028 CHINA JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA 9

2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice.