NETWORKS DATA CENTER SWITCHES USER MANUAL

Similar documents
NETWORKS S2800 & S3900 SERIES SWITCHES USER MANUAL

Installing the Cisco SFS 3504 Server Switch

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

Flex Pro Series Assembly Guide

Broadband Automatic Disconnect Switch. User Manual

hyperion ! This device requires a downloaded phone app in Instruction Manual Data Transfer Module

Installation and Maintenance

Aruba JL311A Cable Guard Installation Instructions

62533 Ethernet Adapter

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Installing and Managing the Switch

Rackmount Keyboard Installation Instructions. Revision A A-0000

Installation and Configuration Guide

S82S (3/7.5-W Models)

Installing the Cisco Unified Videoconferencing 3545 MCU

16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

Zonit μats TM Users Guide μats1-lv Version 1.2

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

L2/L4 Managed Gigabit Ethernet Switch GS-4210 Ultra PoE Series

Switched Rack Power Distribution Unit

Quick Start Guide. C-100 Series Switches

CR Getting Started Guide

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco AS5400XM Universal Gateway

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide

L2+ Managed Gigabit Switch WGSW series

TRC2002 2U RACKMOUNT COMPUTER

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

Quick Install Guide AMS-4424P AV Series 26-Port Gigabit Stackable PoE+ L2/L3 Managed Switch

L2+ Managed Metro Ethernet Switch MGSW / MGSD Series

Management Security Switch SGSD-1022 / SGSD-1022P SGSW-2840 / SGSW-2840P. Quick Installation Guide

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

iconverter 2-Module Power Chassis

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking

WARRANTY & LIMITATION OF LIABILITY

LED FOLDING WORKLIGHT TM

WARRANTY & LIMITATION OF LIABILITY

24-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch

Preparing to Install the VG248

CMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1

SwitchBlade Switch Controller Quick Install Guide

Cisco 200 Series Smart Switches. Quick Start Guide

PCMCIA Flash Card User Guide

Rapier Series Switch Quick Install Guide

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

Online Connection Kit. Installation Manual

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide

LifeSize ClearSea Installation Guide August 2012

1U Short-Depth Rackmount Console with 19 Display For KVM Switch or Server

Skywire Miner. Assembly Manual. Contact. . #1101 South Tower, No.1839 Qixin Road, Minhang, Shanghai, P.R.

Multi-port Coax + 2-port 10/100/1000T + 2-port. 100/1000X SFP Long Reach PoE over Coaxial. Managed Switch LRP-822CS / LRP-1622CS

Start Here. All-in-One Printer. Print Copy Scan

ES-600 Ozone Controller Operation Manual

ExtremeSwitching 210 and 220 Series Switches: Hardware Installation Guide

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

12-Bay Docking Station Standard Battery Version User Guide

L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series

PIX 520. PIX 520 Product Overview CHAPTER

Instructions. RM3000 Rackmount Kit for TDS3000 Series Oscilloscopes

TB-100 ControLynx Terminal Block

24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide

48-Port 10/100Mbps + 4 Gigabit TP / 2 SFP. Managed Switch WGSW Quick Installation Guide

TRC4011 4U RACKMOUNT COMPUTER TVC U Rackmount. Video Display Wall Controller

Quick Start Guide. AR530&AR550 Series Industrial Switching Routers. Issue: 07 ( ) Part number: HUAWEI TECHNOLOGIES CO.

Quick Start Guide S X. 1. Unpacking the Switch. 2. Identifying Your System. Front View

pakedgedevice&software inc.

LVN5200A-R2, rev. 1, Hardware Installation Guide

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide

Catalyst 2360 Switch Getting Started Guide

4x4 Seamless HDMI matrix & 2x2 Video Wall Controller

Operating Instructions

Quick Start Guide. NetDirector Console KVM Switch (8- or 16-Port) or Rackmount KVM Switch (8-Port)

H3C S12500 Routing Switch Series

Sign-Up Timeclock Set-up Departments & Employees Troubleshooting Device Installation Warranty

User Guide. Control Box. RoscoLED TM.

HDTVMT User Manual

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

DCM Digital Control Modules

Vocia ELD-1. Operation Manual

L2+ Managed LCD Switch GS T2XV(R) / GS T4XV(R) Quick Installation Guide

DV-HDA-14AUD 1x4 HDMI Distribution Amplifier Manual

Aruba 3000 Multi-Service Mobility Controller Series. Installation Guide

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

LAUNCH TECH CO., LTD.

Chroma-Q Magic Box EthernetSwitch 7

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

SAVE THESE INSTRUCTIONS

Operation Manual. Equipment. Operation Manual. Loctite RB30 Robot Camera. Part Number:

INSTRUCTION MANUAL 4 UNIT AES SWITCH MODEL R198 S/N

Dell Networking S4100-ON Series. Set-Up Guide

MEC-COM-M114. User s Manual

Rack Power Distribution Unit AP7530, AP7540

1. Introduction: 2. Parts List:

8x8 HDMI2.0 Matrix Support YUV4:4:4, 18Gbps, HDR. Operating Instruction

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Transcription:

NETWORKS DATA CENTER SWITCHES USER MANUAL

Contents Chapter 1 Introduction... 1 Chapter 2 Mounting the Switch... 2 2.1 Environmental Requirements... 2.2 Rack-Mount Installation... 2.3 Install the Switch on a Workbench... 3 2 2 Chapter 3 Configuring the Switch... 4 3.1 Building Configuration Platform and Connecting Cable... 4 3.2 Setting Terminal Parameter (Windows super terminal)... 4 3.3 Setting Terminal Parameter (SecureCRT from VanDyke Software) 5 Chapter 4 Maintenance and Troubleshooting... 6 4.1 Loading Failure Processing... 6 4.2 User Password Lost... 6 4.3 Power System Troubleshooting... 6 4.4 Configuration System Troubleshooting... 7 4.5 No Information on the Terminal...7 Product Warranty Card

Chapter 1 Introduction Thank you for purchasing the.com Data Center Switch. The S5800, S5850, S8050-series switches come with complete system software with comprehensive protocols and applications to facilitate rapid service deployment and management for both traditional L2/L3 networks and Data Center networks. S5800, S5850, S8050-Series Switches Figure 1-1 Before you begin installing the switch, make sure you have all of the package contents available. Package Contents.COM S5800, S5850, S8050 Series Ethernet Switch Rackmount Kit Console Cable Power Cord Grounding Cable User Manual CAUTION: Multiple power sources may be provided. To de-energize, all power connections need to be removed, including RPS cable if provided. CAUTION: No user serviceable parts inside. Must be serviced by technically qualified personnel. This User Manual will familiarize you with the layout of the N-series Cumulus Linux switches and describe how to deploy the device in your network. For additional information, see www.fs.com. Data Center, Enterprise & ISP Network Solutions 01

Chapter 2 Mounting the Switch 2.1 Environmental Requirements There are two ways to mount the switch: Set the switch on a flat surface. Mount the switch in a standard rack (1 rack unit high). Before you begin installing your switch, prepare the installation site. Make sure your operating environment meets the operating environment requirements of the equipment. Ambient Temperature: Ambient temperature between 0 C and 45 C. No nearby heat sources such as direct sunlight, warm air exhausts, or heaters. Air Flow: Both side panels must be unobstructed to prevent overheating, adequate airflow in room or wiring closet. Mechanical Loading: The device must be level, stable, and secure to prevent it from sliding or shifting out-of-position. Circuit Loading: Adding the device to the power outlet must not overload that circuit. Grounding: Rack-mounted equipment should be properly grounded to guarantee lightening protection and anti-jamming. 2.2 Rack-Mount Installation Step 1: Wear ESD-preventive wrist strap, and check the grounding and stability of rack. Step 2: Fix the tray to a proper position of rack horizontally. Step 3: Take out screw (complete package with front hangers), and install one end of the Front Mounting Brackets on switch. Figure 2-1 Data Center, Enterprise & ISP Network Solutions 02

Step 4: Place switch on the tray horizontally, push it slightly into the rack along the tray, and fix the other end of Front Mounting Brackets upon the front hold strip of rack using screw and its matching floating nut. Figure 2-2 Installation Recommendations: When installing a variety of equipment on the same cabinet, it is recommended to install the heavy equipment at the bottom or near the bottom of the cabinet to reduce the center of gravity of the cabinet. 2.3 Install the Switch on a Workbench In many cases, users do not have a standard 19" rack, so people often place switches on a cleaning working platform. Such operation is relatively simple, and the only following aspects should be concerned during operation: Ensure the working platform is stable and well earthed. A 10 cm space around switch is left for heat dissipation. Do not place heavy objects on switches. Data Center, Enterprise & ISP Network Solutions 03

There are 4 foot pads that come with the device. Paste them onto the bottom near the corners of the switch, as shown below: Figure 2-3 Chapter 3 Configuring the Switch 3.1 Building Configuration Platform and Connecting Cable Connect DB-9 hole-type plug of configuration cable to the serial port for configuring switch. Connect RJ-45 end of configuration cable to the console port of switch. Note: Please use the DB-9 to RJ-45 Console cable which we provide together with this device. Use the DB-9 to RJ-45 Console cable from other vendors maybe can t access this device. 3.2 Setting Terminal Parameter (Windows super terminal): Turn on PC and run emulator program (eg. Windows system has its own super terminal) on PC. Set terminal parameters (take the super terminal setting of Windows XP as an example). Step 1: Click Start Program Attachment Communication Super Terminal to enter the Super Terminal window and establish a new connection, then a connection description interface will pop up. Step 2: Type the name of the new connection in the Name text box (For example: Network) and click OK. The following dialog box appears. Select the serial port to be used from the connect using drop-down lists. Data Center, Enterprise & ISP Network Solutions 04

Step 3: When the Network Properties dialog box is displayed as shown in following figure. Set Bits per second to 115200, Data bits to 8, Parity to None, Stop bits to 1, and Flow control to None. (In other Windows operating systems, bits per second may be described as baud rate and data stream control may be described as traffic control.) Step 4: Click OK after setting the serial port parameters and input the user name/password: admin/admin, then enter the HyperTerminal window. Step 5: Click Properties in the HyperTerminal window to enter the Network Properties dialog box. Click the Settings tab, set the emulation to VT100, and then click OK. Note: Please use the DB-9 to RJ-45 Console cable which we provide together with this device. Use the DB-9 to RJ-45 Console cable from other vendors maybe can t access this device. 3.3 Setting Terminal Parameter (SecureCRT from VanDyke Software): Install the SecureCRT software on PC. Set SecureCRT Serial terminal parameters. Step 1: Click Quick Connect button to enter the SecureCRT quick connect window. Step 2: Choose the Serial as the Protocol. Step 3: In the Port item, please choose specified COM port that the PC is using. (Here we take COM4 as an example.) Step 4: Set Baud rate to 115200, Data bits to 8, Parity to None, Stop bits to 1, and Flow control to XON/XOFF. Then click Connect button to enter the Serial display interface. Step 5: If the network advice is connected with PC via Serial cable, you could see the command line interface (CLI) when you push down the Enter button of the PC. Note: Please use the DB-9 to RJ-45 Console cable which we provide together with this device. Use the DB-9 to RJ-45 Console cable from other vendors maybe can t access this device. Data Center, Enterprise & ISP Network Solutions 05

Chapter 4 Maintenance and Troubleshooting 4.1 Loading Failure Processing: After loading fails, the system will keep running in the original version. At this time, users should re-check if physical port connections are good firstly. If some ports are not connected, then re-connect them to ensure that physical connections are correct, and begin re-loading. If physical connections are correct, then check the loading process information displayed on the super terminal to verify if there are input errors. If there are input errors, correct them and re-load. For example, when using TFTP protocol, we enter incorrect IP addresses of Server and Switch, name of loading software, do not specify the correct working path of correct TFTP server and so on; if physical connections are good, and there are no input errors in the loading process but the loading fails finally, please contact agents for help. 4.2 User Password Lost: If system password is lost or forgotten, the following method can be used to reset password: 1. Enter uboot operation mode. (See the further information. Refer to the Chapter 7 of Switch Installation Guide on website for how to enter.) 2. Input boot_flash_nopass command to start system in uboot mode. Note: Please use the DB-9 to RJ-45 Console cable which we provide together with this device. Use the DB-9 to RJ-45 Console cable from other vendors maybe can t access this device. 4.3 Power System Troubleshooting: Switch can judge if its power system is faulty according to the PWR indicator on the front panel: when power system works normally, the PWR indicator shall always keep lighting; when the PWR indicator is off, please check if: 1. The power line of switch is connected correctly. 2. EPS of switch matches the power required by switch. Not all models will have all of the features described. Data Center, Enterprise & ISP Network Solutions 06

4.4 Configuration System Troubleshooting: After the switch is powered on, if system is normal, the startup information will be displayed on the configuration terminal; If the configuration system is faulty, the configuration terminal may display no information or hashes. 4.5 No Information on the Terminal: After power-on, if no display information on configuration terminal appears, please check if: The power is normal. The cable of configuration port (Console) is properly connected. If no problems have been found after the above checks, it is possible that configuration cable is faulty or the parameter setting of terminal (such as super terminal) are incorrect, please check accordingly. Troubleshooting for the terminal displaying hashes: If the configuration terminal displays hashes, it is probable that the parameter setting of terminal (such as super terminal) are incorrect Please confirm the parameter setting of terminal (such as super terminal): baud rate: 115200, data bit: 8, parity: no, stop bit: 1, flow control: NA, selecting terminal emulation: VT100. Data Center, Enterprise & ISP Network Solutions 07

Hardware Warranty Card ensures our customers that any damage or faulty items due to our workmanship, we will offer a free return within 30-Days from when you receive your goods. This excludes any custom made items or tailored solutions. What this warranty covers? This warranty is only available for the original buyer and is not transferable to a third-party. What is NOT covered? This warranty is non-transferable and does not cover if the product: Within the first 30 Days of purchase, if for any reason you are not satisfied with your purchase (except custom made items or tailored solutions), simply return it for a refund or replacement. Within the first 1 Year of purchase, free repair or maintenance due to manufacturer s defects (including shipping, handling and parts costs). Within 20 Years of purchase except for the first 1 year, repairs and maintenance will be charged. Has been modified and/or altered, or an addition made thereto, except by authorized representatives, or as approved by in writing. Has been painted or physically modified in any way. Has been subjected to misuse, abuse, negligence, abnormal or physical stress, including accident. Has been damaged or impaired as a result of using third party firmware. Has no original label, or miss any other original labels. sole and exclusive obligation and liability under the foregoing warranty shall be for, at its discretion, to repair or replace any product that fails to conform to the above warranty during the warranty period. The expense of removal and reinstallation of any product is not included in this warranty. The warranty period of any repaired or replaced products shall not extend beyond its original warranty expiry. Return Conditions If you return for refund or replacement within 30 Days, please make sure that the product must be in new or like-new condition with its original trademark and SN number (the SN number is the unique identification number of every product), manual and accessories that were included when delivered to you. Return for replacement or repair is due to an error on our part (you received an incorrect or defective item, etc. ), we will cover the shipping and repair cost and customs duty (for international purchase). Otherwise, you are responsible for these charges of returning or repairing items on your own.

offers two channels to process your return request, if you purchase from website, you may visit the website and log in to your account center to start a quick return. If you purchased by emails, you may contact your sales representative or visit our website fs.com to talk with customer service team and obtain an approved Return Materials Authorization (RMA) Number. Products returned without a RMA Number will not be processed and will be returned freight collect or subject to disposal. Information on how to start return can be found at https://www.fs.com/day_return_policy.html