Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

Similar documents
Configuring the MSA1000 for Linux or NetWare Environments

Upgrading the MSA1000 for Enhanced Features

DtS Data Migration to the MSA1000

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide

HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes

QuickSpecs SmartStart TM Release 6.0

Marvell BIOS Utility User Guide

QuickSpecs. What's New. Models. ProLiant Essentials Server Migration Pack - Physical to ProLiant Edition. Overview

QLogic iscsi Boot for HP FlexFabric Adapters User Guide

HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory. July 2003 (Second Edition) Part Number

HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment

StorageWorks Dual Channel 4Gb, PCI-X-to-Fibre Channel Host Bus Adapter for Windows and Linux (Emulex LP11002)

ProLiant DL F100 Integrated Cluster Solutions and Non-Integrated Cluster Bundle Configurations. Configurations

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

QuickSpecs. Compaq Smart Array 431 Controller M ODELS

QuickSpecs. Models. Overview

HP MSA Family Installation and Startup Service

HP ProLiant Hardware Inventory Tool for Configuration Manager 2007 User Guide

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Computer Setup (F10) Utility Guide HP Elite 7000 MT Series PCs

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide

HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation

QuickSpecs. Models. Overview

HP StorageWorks MPxIO for Sun Solaris application notes

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

QuickSpecs. What's New Support for HP software and hardware server support. Models. HP Insight Server Migration software for ProLiant v.3.

HP BladeSystem Matrix Compatibility Chart

Configuring RAID with HP Z Turbo Drives

HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service

QuickSpecs. What's New HP 120GB 1.5Gb/s SATA 5400 rpm SFF HDD. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

QuickSpecs. Models. HP StorageWorks 8Gb PCIe FC HBAs Overview

HP Accelerated iscsi for Multifunction Network Adapters User Guide

HP ProLiant Storage Server iscsi Feature Pack

HP ALM Client MSI Generator

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes

System information update for system board replacement events

HP StorageWorks MPxIO for Sun Solaris application notes

HPE Knowledge Article

HP Server Novell NetWare Installation Guide

Intelligent Provisioning 3.00 Release Notes

QuickSpecs. What's New. Models. HP ProLiant Essentials Performance Management Pack version 4.5. Overview. Retired

QuickSpecs. HP SANworks Storage Resource Manager. Overview. Model HP SANworks Storage Resource Manager v4.0b Enterprise Edition.

QuickSpecs. What's New. Models. Overview

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment

QuickSpecs. HP StorageWorks ds2110. HP StorageWorks ds2110. Description HP StorageWorks Disk System 2110 (ds2110)

Fully integrated and tested with most ProLiant servers and management software. See list of servers with each adapter specifications.

HP StorageWorks Modular Smart Array 1500 cs application note

Intelligent Provisioning 2.70 Release Notes

HP Color LaserJet Managed E55040 Series Firmware Readme

Intelligent Provisioning 1.70 Release Notes

HPE RDX Utility Version 2.36 Release Notes

Implementing Microsoft Windows Small Business Server 7 (SBS 7) public preview build on HP ProLiant servers

External Devices. User Guide

HP D6000 Disk Enclosure Direct Connect Cabling Guide

HP 3PAR OS MU1 Patch 11

HP Online ROM Flash User Guide. July 2004 (Ninth Edition) Part Number

Computer Setup (F10) Utility Guide HP Business Desktops dx5150 model

Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620

QuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview.

Retired. Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

HPE OneView for Microsoft System Center Release Notes (v 8.2 and 8.2.1)

Retired. Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

QuickSpecs. Models ProLiant Cluster F200 for the Entry Level SAN. Overview

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

Intelligent Provisioning 3.10 Release Notes

HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system.

EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment

HP 3PAR Host Explorer MU1 Software User Guide

Disaster Recovery Guide for Windows 2008 and RHEL 5.x platforms with external disk support

QuickSpecs. Models HP SC11Xe Host Bus Adapter B21. HP SC11Xe Host Bus Adapter. Overview

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter

External Devices User Guide

QuickSpecs. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

Intelligent Provisioning 1.64(B) Release Notes

Smart Array Controller technology: drive array expansion and extension technology brief

QuickSpecs. Useful Web Sites For additional information, see the following web sites: Linux Operating System. Overview. Retired

Best Practices When Deploying Microsoft Windows Server 2008 R2 or Microsoft Windows Server 2008 SP2 on HP ProLiant DL980 G7 Servers

The use of the HP SAS Expander Card requires a minimum of 256MB cache on the SA-P410 or SA-P410i Controller.)

HP LaserJet MFP Analog Fax Accessory 300. Supplemental Information

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems

External Devices User Guide

HP StorageWorks Continuous Access EVA 2.1 release notes update

Microsoft Windows Server 2008 On Integrity Servers Overview

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter

Computer Setup (F10) Utility Guide HP Compaq d220 and d230 Microtower

Models Compaq NC3123 Fast Ethernet Adapter PCI, 10/100 WOL B21 Single B22 5-Pack

Quick Setup & Getting Started

QuickSpecs. Models. HP StorageWorks Modular Smart Array 30 Multi-Initiator (MSA30 MI) Enclosure. Overview

SUSE Linux Enterprise Server 11 Support Pack 2 Support Notes

HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

HP StorageWorks Data Protector Express ProLiant Edition 3.1 SP4. Overview

RAID-01 (ciss) B Mass Storage Driver Release Notes

External Media Cards User Guide

External Devices User Guide

Imaging the HP Z240 Workstation

HP MSA2000 Family VDS and VSS Hardware Providers installation guide

Transcription:

Technical Note Revised October 2006 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Configuring the StorageWorks MSA1000 and MSA1500cs for External Boot with NetWare Considerations...3 Initial Steps...4 Install Host Bus Adapter (HBA) in the Server...4 Setup for RBSU Servers...4 Setup for Servers without RBSU...4 Configuration of Volume(s) on MSA1000/MSA1500cs...5 Configuration of Boot BIOS with Qlogic BIOS Utility...15 Installation of Operating System...24 Completing the OS install to the Server...24 Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations Abstract: This technical note outlines step-by-step procedures for configuring the HP StorageWorks MSA1000/MSA1500cs, servers, and Fibre Channel Host Bus Adapters for external boot.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 2 Notice 2007 Hewlett Packard Company HP, Hewlett Packard, Compaq, StorageWorks, SmartArray, SupportPaq, and the Compaq logo are trademarks of Compaq Information Technologies Group L.P. Microsoft, Windows, and Windows NT are trademarks and/or registered trademarks of Microsoft Corporation. Other product names mentioned herein may be trademarks of their respective companies. Hewlett Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided as is without warranty of any kind and is subject to change without notice. The warranties for Hewlett Packard Company products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 3 Considerations Please read and understand the following: These steps and procedures are intended for an advanced user who has a solid foundation of knowledge in server hardware, storage hardware, and the NetWare operating system and installation. These procedures currently apply only to Novell NetWare versions 5.x and 6.x. All prerequisites and current scaling limitations for StorageWorks MSA1000 and MSA1500cs apply. You must download the Host bus adapter (HBA) driver files from the WEB to a floppy drive for a part of the OS installation. o For Novell NetWare HP supports QLogic based HBAs. Go to www.hp.com and select Software and Driver Downloads from the left menu. Find your HBA and desired driver, download, and if needed, unpack the drivers. Have them ready on a floppy drive for the OS installation. Do not use SmartStart to install OS on the server. Do not perform any configuration (using Array Configuration Utility) on internal drives until the installation of the operating system has been completed on the StorageWorks MSA1000 or MSA1500cs. These procedures assume a clean install on both the server and the StorageWorks MSA1000 or MSA1500cs in other words, both are new, out of the box and have not previously been configured. Selective Storage Presentation must be used if multiple servers are to access volumes on the same MSA1000/MSA1500cs. Although the MSA1500cs support both SCSI and SATA drives, it is not recommended to use SATA drives for your external boot device. SCSI drives are the most reliable and should be used if available.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 4 Initial Steps Install Host Bus Adapter (HBA) in the Server Install the HBA in an open slot in the server. Connect the appropriate fibre cables to the HBA and interconnect devices. Review the install documentation that came with the HBA or the Quick Install Guide (MSA 1000/MSA1500cs) for detailed instructions. Setup for RBSU Servers 1. Make sure you have the latest ROM BIOS installed on your server. If needed, there are several options available to upgrade the BIOS; you can download the Firmware Maintenance CD from www.hp.com, or you can download individual components for your specific server. 2. Set the boot order: a. While the system is booting, Press F9 to start the ROM Setup Utility. b. Choose Boot Controller Order. c. Select the primary HBA and move it to Controller Order 1. d. Exit the utility. Setup for Servers without RBSU If your server does not have RBSU, perform the following steps: 1. Download and install the latest system ROM from the website: http://www.hp.com. 2. Download SOFTPAQ SP18002 from ftp://ftp.compaq.com/pub/softpaq/sp18001-18500/. 3. Run the SOFTPAQ program to create an upgrade diskette. 4. Boot from the ProLiant Smart Start CD-ROM and run the program to clear the configuration. 5. Reboot from the new upgrade diskette. The ORD.EXE program should start automatically. 6. Set the Primary HBA to Position 1. 7. Reboot the server.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 5 Configuration of Volume(s) on MSA1000/MSA1500cs 1. Power on the server with HP StorageWorks Modular SAN Array 1000 and 1500cs Support Software CD in the CD-Rom. 2. Select the desired language and keyboard settings.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 6 3. Accept the License Agreement by clicking Agree. 4. Select the Array Configuration Utility.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 7 5. Select the appropriate Array controller from the list to the left. 6. The selected array controller and available drives will be displayed. Click on Create Array in the right pane

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 8 7. Select the drives to be included in the array and choose OK 8. Select the Create Logical Drive command

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 9 9. Configure the volume with the Fault Tolerance and parameters desired and choose OK 10. Click Save to commit the changes.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 10 11. Click OK on the popup window. 12. Saving Configuration will be displayed for a few seconds

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 11 13. When the configuration is saved, you are back to the main menu: 14. To restrict access to the newly created LUN, you have to enable Selective Storage Presentation. Click on the Selective Storage Presentation link in the right pane. 15. This opens a new window in the right pane; select Enable and click OK.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 12 16. This will display a list of all known WWN to the MSA controller. 17. Pick the one for your server, give it a logical name, set the correct Host mode for your OS and give the server access to the LUN. If you have multipathing, you have to select both HBA s in the server, give them unique names, and give both access to the LUN.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 13 18. Click OK, and accept the warning by clicking OK. 19. Click Save.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 14 20. This brings you back to the main menu. Click on Exit in the lower left corner, and then click Exit in the upper right corner. Click OK on the popup window. 21. Configuration of the MSA1000/MSA1500cs is complete. 22. Remove the HP StorageWorks Modular SAN Array 1000 Support Software CD from the CD-Rom and prepare to configure the boot BIOS in the next section.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 15 Configuration of Boot BIOS with Qlogic BIOS Utility As the Server typically will boot to an internal drive, the server has to be configured to boot via the Fibre Channel Host Bus Adapter. The following steps illustrate this. 1. Power on the server. As the server boots, the menu prompt for the HBA will display. Press <CTRL Q> to start the QLogic (Fast!UTIL ) BIOS Utility.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 16 2. At the QLogic main menu, select Configuration Settings and press Enter 3. Select the first option Adapter Settings and press Enter.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 17 4. By default, the Host Adapter BIOS is disabled. Arrow down to Disabled, and press Enter to Enable. 5. Once the Bios is Enabled, the options will look like this:

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 18 6. Press the Escape key to back up one menu, and arrow down to Selectable Boot Settings, and press Enter to select it. 7. By default, the Selectable Boot option is disabled. Press Enter to Enable it.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 19 8. After enabling, it will look like this. Arrow down to (Primary) Boot Port Name, Lun:, and press Enter.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 20 9. Next, you are presented with a list of devices found on the SAN. Note: If you do not see any devices listed, there is a fibre cabling problem that will need to be root caused. Arrow down to the MSA1000/1500cs that you want to boot from (In this example, we are showing two MSA1500cs s in the SAN). Once the correct MSA is highlighted, press Enter. 10. The next screen shot shows the available LUNs on the selected MSA controller. Arrow down to the LUN that you want to boot from, and press Enter to select.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 21 11. Once the Boot LUN is selected, the screen will appear as follows: 12. Press the Escape Key, and press Enter to Save Changes.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 22 13. Press the Escape Key again, and select Exit Fast!UTIL 14. Select the Reboot System option. The server will now attempt to boot from the volume controlled by the MSA1000.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 23 15. As the Server is going through POST (Power On Self Test), you will see a screen like the one below, showing that the QLogic BIOS is active, and has a LUN to attempt to Boot from. 16. It is important to note that the Server will fail in attempting to Boot from this LUN, as no Operating System has yet to be installed on this boot Volume. See the following section, Installation of Operating System for the final steps.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 24 Installation of Operating System Completing the OS install to the Server 1. Install DOS on the boot disk. See your DOS Operating System Vendor s documentation for creating a bootable DOS partition. 2. Follow the standard NetWare instructions to begin the installation. Typically this is accomplished by loading the DOS CD ROM device drives, and at the CD Drive prompt, running the NetWare install (INSTALL.BAT). 3. At the Welcome to the NetWare server installation screen, select a Custom and New Server install. This is necessary to allow the QLogic drivers to be loaded at the proper time.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 25 4. After several other install / interview questions, the install will begin, with a progression bar showing install status 5. At some point during the install, you will be notified of the detected drivers. When prompted, you will want to load additional drivers to support the QLogic HBA and the MSA1000/MSA1500cs. Arrow down to Modify, and press Enter. Arrow down to Storage adapters: and press Enter. The screen will look like this:

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 26 6. Press the Ins key to Add an additional driver. After pressing Ins, the screen will look like this: 7. Press the Ins key again to Add an unlisted driver. After pressing the Ins key, the screen will look like this:

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 27 8. Use the floppy disk you have prepared as noted under the Consideration chapter of this document. Place the floppy diskette in the floppy drive, and press Enter. You will be presented with a list of possible drivers to load, select QL2300.HAM QLogic QLA2300 PCI Fibre Channel Host Bus Adapter, and press Enter. 9. The install program will load the driver, and the screen will look like this:

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 28 10. You will need to modify the QLogic driver parameters, arrow down to the QL2300.HAM under Driver name, and press Enter. To modify the driver parameters. Press Enter on Select/Modify driver parameters. 11. Add slot number that corresponds to the slot number of the server where the HBA was installed.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 29 12. That will add this device driver to the list to load. Select Return to driver summary and press Enter 13. Select Continue, and press Enter

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 30 14. Once Continue has been press, you will see a screen like the one below, where the Operating System is loading the drivers. 15. The installation will now continue normally. Depending on the hardware installed, you may or may not need to load additional drivers for Network adapters, etc. For this demonstration, it is assumed that no other drivers need to be loaded.

Configuring the MSA1000/MSA1500cs for External Boot - NetWare 31 16. Finally, you will be asked to create the first NetWare volume SYS. Chose the size of this volume, and follow the standard NetWare installation procedure to complete the installation. Note that the Device it is being created on is the MSA1000. NetWare has now been successfully installed to a Boot LUN on the MSA1000/MSA1500cs.