Datasheet - SRB 301LC/B-24V

Similar documents
Datasheet SRB301ST 24V (V.2)

Datasheet - SRB 402EM-24V

Datasheet - SLB 200-C04-1R

Datasheet - MZM 100 B ST-1P2PW2REM-A

Datasheet - AZM300Z-ST-1P2P-A

Datasheet - AZM 200SK-T-1P2PW

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Datasheet - CSS 11-30S-D-M-ST

Datasheet - RSS 36-D-R-ST

Datasheet AZM 161 Z ST1 AS RA

Datasheet - BNS ZG-ST

Datasheet - BNS ZG

Datasheet - AZM 200 BZ ST-T-AS P

Datasheet - ZS Z

Datasheet - ZR Z

Datasheet - AZ 16-02ZVRK-ST

Datasheet - AZ 15 ZVRK

Datasheet - AZ 16-03ZVRK

Datasheet - ZR Z

Datasheet - AZ 15 ZVRK

Datasheet - AZ 16-02ZVK

Datasheet - AZ 15 ZVRK

Datasheet - AZ 15 ZVK

Datasheet - AZ 16ZVRK

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

Datasheet - AZ 15 ZVRK

Safety controlling systems PROTECT series / Version 02

Operating instructions Safety-monitoring module SRB301STV.2 /CCV.2 /PCV.2 SRB301STV.3 /CCV.3 /PCV About this document.

Operating instructions Safety-monitoring module SRB 301LC/B SRB 301LC/B-R. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301LC / LCI / LCI/7. 1. About this document. Content

Operating instructions Safety-monitoring module SSW 301HV. 1. About this document. Content

E-STOP relays, safety gate monitors

Operating instructions Safety-monitoring module SRB 301ST V.2. 1 About this document

Operating instructions Fail-safe standstill monitor FWS About this document. Content

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Operating instructions Safety-monitoring module SRB 324ST V About this document. Content

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Operating instructions Safety-monitoring module SRB 301ST-230V. 1 About this document

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

E-STOP relays, safety gate monitors

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

E-STOP relays, safety gate monitors

Operating instructions Safety-monitoring modules SRB201ZH -24VDC. 1. About this document. Content

Safe timer relay/contact expansion modules

Operating instructions Safety-monitoring module SRB 301HC/R-24V / -230V. 1 About this document

E-STOP relays, safety gate monitors

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

E-STOP relays, safety gate monitors

Operating instructions Safety-monitoring module SRB 207AN. 1. About this document. Content

Operating instructions Safety-monitoring module SRB-E-204ST / SRB-E-204PE. Content. 1. About this document

Two-hand control unit

E-STOP relays, safety gate monitors

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

E-STOP relay, safety gate monitor

Contact expander modules

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

E-STOP relay, safety gate monitor

Two-hand control unit

Operating instructions Safety-monitoring module SRB 324ST V.3. 1 About this document

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

SAFETY PRESSURE MATS GENERAL PRODUCT FEATURES

PNOZ s1. Safety relays. Operating Manual EN-07

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Two-hand control unit

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Safety relays PNOZsigma

E-STOP relays, safety gate monitors

ITEM ESM-BA301

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

MSR178DP. Description. Features. Specifications

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

E-STOP relays, safety gate monitors

Safe monitoring relays

Transcription:

27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters) Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains 3 safety contacts, STOP 0 1 Signalling output (Minor differences between the printed image and the original product may exist!) Ordering details Product type description SRB 301LC/B-24V Article number 101177962 EAN code 4030661315836 ecl@ss 27-37-19-01 Approval Approval USA/CAN Classification Standards EN ISO 13849-1, IEC 61508, EN 60947-5-1 PL up e (STOP 0) Control category up 4 (STOP 0) DC 99% (STOP 0) CCF > 65 points PFH value 2,0 x 10-8/h (STOP 0) SIL up 3 (STOP 0) Mission time 20 Years - notice The PFH value is applicable for the combinations listed in the table for

contact load (K) (current through enabling paths) and switching cycle number (n-op/y). In case of 365 operating days per year and a 24-hour operation, this results in the specified switching cycle times (t-cycle) for the relay contacts. Diverging applications on request. Global Properties Product name SRB 301LC/B Standards IEC/EN 60204-1, EN 60947-5-1, EN ISO 13849-1, IEC 61508 Compliance with the Directives (Y/N) Climatic stress EN 60068-2-78 Mounting snaps onto standard DIN rail to EN 60715 Terminal designations IEC/EN 60947-1 Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic, ventilated - Material of the contacts, self-cleaning, positive action Weight 230 g Start conditions Automatic or Start button Start input (Y/N) Feedback circuit (Y/N) Start-up test (Y/N) Automatic reset function (Y/N) Reset with edge detection (Y/N) Pull-in delay - ON delay with automatic start 300 ms - ON delay with reset button 20 ms Drop-out delay - Drop-out delay in case of emergency stop 25 ms Mechanical data Connection type Screw connection Cable section - Min. Cable section 0,25 mm² - Max. Cable section 2.5 mm² Pre-wired cable rigid or flexible Tightening torque for the terminals 0,6 Nm Detachable terminals (Y/N) Mechanical life 10.000.000 operations Electrical lifetime Derating curve available on request restistance to shock 30 g / 11 ms Resistance to vibration To EN 60068-2-6 10...55 Hz, Amplitude 0,35 mm, ± 15 % Ambient conditions Ambient temperature - Min. environmental temperature 25 C - Max. environmental temperature +45 C Storage and transport temperature - Min. Storage and transport temperature 40 C

- Max. Storage and transport temperature +85 C Protection class - Protection class-enclosure IP40 - Protection class-terminals IP20 - Protection class-clearance IP54 Air clearances and creepage distances To IEC/EN 60664-1 - Rated impulse withstand voltage Uimp 4 kv - Overvoltage category II To VDE 0110 - Degree of pollution 2 To VDE 0110 Electromagnetic compatibility (EMC) EMC rating conforming to EMC Directive Electrical data Rated DC voltage for controls - Min. rated DC voltage for controls 20.4 V - Max. rated DC voltage for controls 28.8 V Rated AC voltage for controls, 50 Hz - Min. rated AC voltage for controls, 50 Hz 20.4 V - Max. rated AC voltage for controls, 50 Hz 26.4 V Rated AC voltage for controls, 60 Hz - Min. rated AC voltage for controls, 60 Hz 20.4 V - Max. rated AC voltage for controls, 60 Hz 26.4 V Contact resistance Power consumption Type of actuation Switch frequency max. 100 mω max. 1.7 W; 1.9 VA AC/DC max. 5 Hz Rated operating voltage Ue 24 VDC 15% / +20%, residual ripple max. 10% 24 VAC 15% / +10% Operating current Ie Frequency range Electronic protection (Y/N) Fuse rating for the operating voltage 0,08 A 50 / 60 Hz 0,5 A gg D-fuse Inputs Monitored inputs - Short-circuit recognition (Y/N) - Wire breakage detection (Y/N) - Earth connection detection (Y/N) Number of shutters Number of openers Cable length Conduction resistance 2 piece 1500 m with 1.5 mm²; 2500 m with 2.5 mm² max. 40 Ω Outputs Stop category 0 Number of safety contacts 3 piece Number of auxiliary contacts 1 piece Number of signalling outputs

Switching capacity - Switching capacity of the safety contacts max. 250 VAC, 6 A ohmic (inductive in case of appropriate protective wiring) min. 10 V, 10 ma - Switching capacity of the auxiliary contacts 24 VDC, 2 A Fuse rating - Protection of the safety contacts 6 A slow blow - Fuse rating for the auxiliary contacts 2 A slow blow Utilisation category To EN 60947-5-1 Number of undelayed semi-conductor outputs with signaling function Number of undelayed outputs with signaling function (with contact) Number of delayed semi-conductor outputs with signaling function. Number of delayed outputs with signalling function (with contact). Number of secure undelayed semi-conductor outputs with signaling function Number of secure, undelayed outputs with signaling function, with contact. Number of secure, delayed semi-conductor outputs with signaling function AC-15: 230 V / 6 A DC-13: 24 V / 6 A 1 piece 3 piece Number of secure, delayed outputs with signaling function (with contact). LED switching conditions display LED switching conditions display (Y/N) Number of LED s LED switching conditions display - The integrated LEDs indicate the following operating states. - Position relay K1 - Position relay K2 - Supply voltage 4 piece - Internal operating voltage Ui Miscellaneous data Applications Emergency-Stop button Guard system Pull-wire emergency stop switches Safety light curtain Safety sensor Dimensions Dimensions - Width 22.5 mm - Height 100 mm - Depth 121 mm notice Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

notice - Wiring example Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R); cross-wire monitoring and feedback circuit (H2) The control system recognises wire-breakage and earth faults in the monitoring circuit. Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. For 1-channel control, connect NC contact to S11/S12 and bridge S12/S22 Connect potential p-type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential. Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X2. If the feedback circuit is not required, establish a bridge The wiring diagram is shown with guard doors closed and in de-energised condition. Documents Operating instructions and Declaration of conformity (es) 236 kb, 03.01.2014 Code: mrl_srb_301lc_b_es Operating instructions and Declaration of conformity (es) 236 kb, 03.01.2014 Code: mrl_srb_301lc_b_es Operating instructions and Declaration of conformity (nl) 236 kb, 03.01.2014 Code: mrl_srb_301lc_b_nl Operating instructions and Declaration of conformity (nl) 236 kb, 03.01.2014 Code: mrl_srb_301lc_b_nl Operating instructions and Declaration of conformity (pt) 240 kb, 27.11.2013 Code: mrl_srb_301lc_b_pt Operating instructions and Declaration of conformity (pt) 240 kb, 27.11.2013 Code: mrl_srb_301lc_b_pt Operating instructions and Declaration of conformity (fr) 250 kb, 28.01.2014 Code: mrl_srb_301lc_b_fr Operating instructions and Declaration of conformity (fr) 250 kb, 28.01.2014 Code: mrl_srb_301lc_b_fr Operating instructions and Declaration of conformity (de) 242 kb, 30.09.2013 Code: mrl_srb_301lc_b_de Operating instructions and Declaration of conformity (de) 242 kb, 30.09.2013 Code: mrl_srb_301lc_b_de Operating instructions and Declaration of conformity (da) 319 kb, 29.08.2013 Code: mrl_srb_301lc_b_da Operating instructions and Declaration of conformity (da) 319 kb, 29.08.2013 Code: mrl_srb_301lc_b_da Operating instructions and Declaration of conformity (pl) 268 kb, 20.03.2014 Code: mrl_srb_301lc_b_pl Operating instructions and Declaration of conformity (pl) 268 kb, 20.03.2014 Code: mrl_srb_301lc_b_pl

Operating instructions and Declaration of conformity (it) 233 kb, 03.01.2014 Code: mrl_srb_301lc_b_it Operating instructions and Declaration of conformity (it) 233 kb, 03.01.2014 Code: mrl_srb_301lc_b_it Operating instructions and Declaration of conformity (en) 233 kb, 30.09.2013 Code: mrl_srb_301lc_b_en Operating instructions and Declaration of conformity (en) 233 kb, 30.09.2013 Code: mrl_srb_301lc_b_en Operating instructions and Declaration of conformity (jp) 337 kb, 03.01.2014 Code: mrl_srb_301lc_b_jp Operating instructions and Declaration of conformity (jp) 337 kb, 03.01.2014 Code: mrl_srb_301lc_b_jp Wiring example (99) 15 kb, 06.08.2009 Code: ksrb3l23 Wiring example (99) 20 kb, 22.08.2008 Code: ksrb3l11 CCC certification (cn) 96 kb, 24.09.2015 Code: q_srbp02 CCC certification (en) 122 kb, 24.09.2015 Code: q_srbp01 EAC certification (ru) 833 kb, 05.10.2015 Code: q_6042p17_ru Images Wiring example

Wiring example Internal wiring diagram K.A. Schmersal GmbH & Co. KG, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 27.01.2016-00:27:18h Kasbase 3.2.1.F.64I