T89C51CC01 T89C51CC01UA T89C51CC01CA. Errata Sheet. CAN Microcontrollers

Similar documents
80C51 MCUs T89C51AC2. Errata Sheet

Application Note. Microcontrollers. Using Keil FlashMon Emulator with AT89C51CC01/03 AT89C51CC01/ Summary. 2. Background overview

CAN, 80C51, AVR, Microcontroller. Application Note

CAN Microcontrollers. Application Note. Migrating from T89C51CC01 to AT89C51CC03. Feature Comparison

Rad Hard FPGA. AT40KEL-DK Design Kit Content. Description. Kit Content. Reference Material. Support

8-bit Microcontroller. Application Note. AVR320: Software SPI Master

AT91 ARM Thumb Microcontrollers. Application Note. AT91 Host Flash Loader. 1. Package Contents. 2. Definition of Terms. 3.

AT89ISP Programmer Cable Introduction AT89ISP Programmer Cable Parallel Port Settings Application Note AT89ISP Software AT89ISP Cable polarized

AT17F Series. Application Note. Programming Circuits for AT17F Series Configurators with Xilinx FPGAs. 1. Introduction

Interfacing the internal serial EEPROM

Application Note Microcontrollers. C Flash Drivers for T89C51RC/RB/IC2 and AT89C51RC/RB/IC2 for Keil Compilers

AVR32 UC3 Software Framework... User Manual

TSC695. Application Note. Annulled Cycle Management on the TSC695. References

AT89C51CC03 UART Bootloader

8-bit RISC Microcontroller. Application Note. AVR 305: Half Duplex Compact Software UART

AT89C5131 Starter Kit... Software User Guide

T89C51AC2 UART Bootloader

T89C5115 UART Bootloader

AT17 Series FPGA. Configuration Memory. Application Note. In-System Programming Circuits for AT17 Series Configurators with Atmel and Xilinx FPGAs

AT89C51SND1 UART Bootloader

MARC4. Application Note. Hints and Tips for Hard- and Software Developments with MARC4 Microcontrollers

8051 Microcontrollers. Application Note. Migration from AT89C5131 & AT89C5131A-L to AT89C5131A-M

8-bit Microcontroller. Application Note. AVR031: Getting Started with ImageCraft C for AVR

FPGA Configuration EEPROM Memory. Application Note. Programming Atmel s EEPROMs: AT17LV020(A) vs. AT17LV002(A) Introduction.

Migration From AT89C51SND1C to AT83C51SDN1C. Application Note. MP3 Microcontrollers

Section 1 ATAVRAUTOEK1 Getting Started

Trusted Platform Module AT97SC3203S. SMBus Two-Wire Interface. Summary

8-bit RISC Microcontroller. Application Note. AVR151: Setup And Use of The SPI

T89C51CC01 CAN Bootloader

8-bit Microcontroller. Application Note. AVR030: Getting Started with C for AVR

AT17(A) Series FPGA Configuration Memory. Application Note

AT89C51CC03 UART Bootloader

SAM Boot Assistant (SAM-BA)... User Guide

MP3 Player Reference Design Based on AT89C51SND1 Microcontroller... User Guide

AT89STK-10 Starter Kit... Hardware User Guide

AT91 ARM Thumb Microcontrollers. Application Note. AT91M55800A Clock Switching Considerations using Advanced Power Management Controller.

T89C51CC02 CAN Bootloader

ATAVRAUTO User Guide

AT94K Series Field Programmable System Level Integrated Circuit. Application Note. FPSLIC Baud Rate Generator

FPGA Configurator Programming Kit (Enhanced) ATDH2200E. Features. Description

AVR501: Replacing ATtiny15 with ATtiny25. 8-bit Microcontrollers. Application Note PRELIMINARY. Features. 1 Introduction

AT89STK-09 Starter Kit for AT83C26... User Guide

ATAVRAUTO User Guide

a clock signal and a bi-directional data signal (SCL, SDA)

System Designer. Programmable SLI AT94K/AT94S Series. Features. Description

256K (32K x 8) 5-volt Only Flash Memory AT29C256

AT89C5122. Application Note. Preventing Windows XP from Displaying Unknown device Message at Startup

System Designer. Programmable SLI AT94K/AT94S Series. Features. Description

ARM7TDMI - based Microcontroller AT91RM3400. Errata Sheet

Two-wire Serial EEPROM Smart Card Modules 128K (16,384 x 8) 256 (32,768 x 8) AT24C128SC AT24C256SC. Features. Description VCC NC

T89C51CC02 CAN Bootloader

AT697E. Application Note. Checking AT697E Code for Occurrence of LDF/FPOPd Instructions Sequence with a dependency on an Odd-Numbered Register

32-bit Secure. AT91SC CT-USB Summary. Microcontrollers. Features

AVR1315: Accessing the XMEGA EEPROM. 8-bit Microcontrollers. Application Note. Features. 1 Introduction

8-bit Microcontroller. Application Note. AVR201: Using the AVR Hardware Multiplier

256K (32K x 8) 5-volt Only Flash Memory AT29C256

8-bit Microcontroller. Application Note. AVR033: Getting Started with the CodeVisionAVR C Compiler

AVR1303: Use and configuration of IR communication module. 8-bit Microcontrollers. Application Note. Features. 1 Introduction

1-megabit (128K x 8) 5-volt Only Flash Memory AT29C010A

AVR32752: Using the AVR32 UC3 Static Memory Controller. 32-bit Microcontrollers. Application Note. Features. 1 Introduction

AVR based 125kHz RFID Evaluation Kit (Re)Programming Guide ATA2270-EK1. Overview. Fuse Settings: ISP Programming

Flash Microcontrollers. Application Note. Migrating from AT89C2051/C4051 to AT89LP2052/LP4052

2-megabit (256K x 8) 5-volt Only Flash Memory AT29C020

Two-Wire Serial EEPROM AT24C164 (1)

Programmable SLI AT40K AT40KAL AT94K. Application Note. Implementing a Single-coefficient Multiplier

4-megabit (512K x 8) 3-volt Only 256-byte Sector Flash Memory AT29LV040A

256 (32K x 8) High-speed Parallel EEPROM AT28HC256N. Features. Description. Pin Configurations

64K (8K x 8) High Speed Parallel EEPROM with Page Write and Software Data Protection AT28HC64BF

hex file. The example described in this application note is written for the AT94K using the FPSLIC Starter Kit. Creating a New Project

Two-wire Serial EEPROM Smart Card Modules 1K (128 x 8) 2K (256 x 8) 4K (512 x 8) 8K (1024 x 8) 16K (2048 x 8)

AT85DVK-07 Demonstration Firmware... User s Manual

AT91 ARM Thumb Microcontrollers. Application Note. Using the ECC Controller on AT91SAM9260/9263 and AT91SAM7SE Microcontrollers. 1.

T89C51CC01 CAN Bootloader

2-Wire Serial EEPROM AT24C01. Features. Description. Pin Configurations. 1K (128 x 8)

AVR32401: AVR32 AP7 Linux Interfacing DataFlash. 8-bit Microcontrollers. Application Note. Features. 1 Introduction

GemCore Serial Lite PRO AT83C21GC. Summary

512K (64K x 8) 5-volt Only Flash Memory AT49F512

4-megabit (512K x 8) Single 2.7-volt Battery-Voltage Flash Memory AT49BV040A

2-wire Serial EEPROM AT24C21. 2-Wire, 1K Serial EEPROM. Features. Description. Not Recommended for New Designs. Pin Configurations.

8-megabyte, 4-megabyte, and 2-megabyte 2.7-volt Only DataFlash Cards AT45DCB008D AT45DCB004D AT45DCB002D. Not Recommended for New Design

Interrupt Controlled UART

1-megabit (64K x 16) 3-volt Only Flash Memory AT49BV1024A AT49LV1024A

CryptoRF EEPROM Memory 8 Kbits

3-Wire Serial EEPROM AT93C46C

4-megabit (512K x 8) Flash Memory AT49BV040B

AVR1503: Xplain training - XMEGA Programmable Multi Interrupt Controller 8-bit Microcontrollers Application Note Prerequisites

2-wire Serial EEPROM Smart Card Modules AT24C32SC AT24C64SC

DatasheetDirect.com. Visit to get your free datasheets. This datasheet has been downloaded by

UART. Embedded RISC Microcontroller Core Peripheral

64K (8K x 8) Parallel EEPROM with Page Write and Software Data Protection AT28C64B. Features. Description. Pin Configurations

AVR097: Migration between ATmega128 and ATmega1281/ATmega bit Microcontrollers. Application Note. Features. 1 Introduction

8051 Microcontrollers. Application Note. Migration from T89C51RD2 to AT89C51RD2/ED2. Feature Comparison

8-bit Microcontroller with 2K/4K/8K Bytes In-System Programmable Flash. Appendix A. Preliminary. ATtiny261 ATtiny461 ATtiny861 Automotive

AVR1922: Xplain Board Controller Firmware 8-bit Microcontrollers Application Note Features 1 Introduction

8-bit Microcontroller. Application Note. AVR033: Getting Started with the CodeVisionAVR C Compiler

1-megabit (64K x 16) 3-volt Only Flash Memory AT49LV1024 AT49LV1025

DIP Top View VCC A12 A14 A13 A6 A5 A4 A3 A2 A1 A0 A8 A9 A11 A10 I/O7 I/O6 I/O0 I/O1 I/O2 I/O5 I/O4 I/O3 GND. TSOP Top View Type 1 A11 A9 A8 A13 A14

512K (64K x 8) 5-volt Only Flash Memory AT29C512

AT91SAM-ICE... User Guide

1-megabit (64K x 16) 5-volt Only Flash Memory AT49F1024 AT49F1025

Transcription:

Active Errata List Timer 2 Baud Rate Generator No IT When TF2 is Set by Software Timer 2 Baud Rate Generator Long Start Time UART RB8 Lost with JBC on SCON Register ADC Interrupt During Idle Conversion CAN CANCONCH Harmless Corruption CAN Sporadic Errors C51 Core Bad Exit of Power-down in X2 Mode Timer0/1 Extra Interrupt Timer1 - Mode 1 Does Not Generate Baud Rate Generator for UART EEPROM - Lock-up During ISP write Transmission after a 3 bit Intermessage Errata History Lot Number Errata List A00151 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 13, 14, 15, 16, 17,18 A00369 1, 3, 4, 5, 6, 7, 8, 9, 10, 12, 13, 14, 15, 16, 17,18 A00367, A00368, A00396 to A00529 1, 3, 5, 6, 7, 8, 9, 10, 12, 13, 14, 15, 16, 17,18 CAN Microcontrollers T89C51CC01 T89C51CC01UA T89C51CC01CA A00510, all lots from A00588 (included) to A03874 (excluded) Lots A03874, A03875, A03876 and all lots from A04440 (excluded) 1, 7, 8, 9,10, 11, 12, 13, 14, 15, 16, 17,18 7, 8, 9,10, 11, 13, 14, 15, 16, 17,18 Errata Sheet Note: For lots between A03876 (excluded) and A04440 (included) it is not determined wether they will have the latest revision errata (7, 8, 9, 10, 11, 13, 14, 15, 16) or the previous revision. Errata Description 1. Flash/EEPROM First Read after Write Disturbed After a write of more than 32 bytes in the EEPROM and 16 bytes in the user Flash memory, the read of the first byte may be disturbed if it occurs just after the write. Do not load/write more than 32 bytes at a time for EEPROM memory. Do not load/write more than 16 bytes at a time for user Flash memory. Or wait 10 ms before reading the first byte. 2. Buffer Noise Large bounces and high noise are generated when buffers are switching (both rising and falling edges). None. 3. Double IT on External Falling Edge on INT1 or INT0 in X2 Mode When the CPU is in X2 mode and Timer 1 or Timer 0 in X1 mode (CKCON = 0x7F), IEx flag is not cleared by hardware after servicing interrupt. In this case, the CPU executes the ISR a second time.

The workaround is to clear IEx bit in Interrupt subroutine. INT1_ISR : CLR IE1... ; Interrupt sub routine 4. Movc Instruction on Boot Memory from Boot Memory Does Not Work No movc instruction is performed when a program running on the boot memory tries to read its own code using a movc instruction. None. 5. Power OFF Flag Power OFF Flag does not work. None. 6. CAN Lost CAN Error Interrupt When a stuff error occurs during a CAN frame transmission on DPRAM write access, the controller does not generate the error interrupt and any received frame can generate a Receive interrupt. None. 7. Timer 2 Baud Rate Generator No IT When TF2 is Set by Software When Timer 2 is used in baud rate generator mode, setting TF2 by software does not generate an interrupt. Use Timer 1 instead of Timer 2 to generate baud rate and interrupt. 8. Timer 2 Baud Rate Generator Long Start Time When Timer 2 is used as a baud rate generator, TH2 is not loaded with RCAP2H at the beginning, then UART is not operational before 10000 machine cycles. Add the initialization of TH2 and TL2 in the initialization of Timer 2. 9. UART RB8 Lost with JBC on SCON Register May lose RB8 value, if RB8 changes from 1 to 0 during JBC instruction on SCON register. Clear RB8 at the beginning of the code and after each time it goes to 1. 10. ADC Interrupt Controller/ADC Idle Mode/Loops In High Priority Interrupt The problem occurs during an A/D conversion in idle mode,if a hardware interrupt occurs followed by a second interrupt with higher priority before the end of the A/D conversion. If the above configuration occurs, the highest priority interrupt is served immediately after the A/D conversion. At the end of the highest priority interrupt service, the processor will not serve the hardware reset interrupt pending. It will also not serve any new interrupt requests with a priority lower than the high level priority last served. 2

Disable all interrupts (Interrupt Global Enablet Bit) before starting an A/D conversion in idle mode, then re-enable all interrupts immediately after. 11. CAN CANCONCH Harmless Corruption When the stuff error occurs (same condition than the errata 6), the CONCH1, CONCH0 bits in CANCONCH are corrupted. This corruption has no effect on the behavior of the Transmit channel. No workaround is required, re-writing CANCONCH to start a new message resolves this corruption. 12. Flash/EEPROM First Read after Load Disturbed In the In-Application Programming mode from the Flash, if the User software application loads the Column Latch Area prior to calling the programming sequence in the CAN Bootloader. The Read after load issue leads to a wrong Opcode Fetch during the column latch load sequence. Update of the Flash API Library. A NOP instruction has to be inserted after the load instruction. MOVX @DPTR,A ;Load Column latches NOP ; ADDED INSTRUCTION 13. CAN Sporadic Errors When BRP = 0 or when BRP > 0 and SMP = 0, the CAN controller may desynchronize and send one error frame to ask for the retransmission of the incoming frame, even though it had no error. This is likely to occur with BRP = 0 or after long inter frame periods without synchronization (low bus load). The CAN macro can still properly synchronize on frames following the error. Setting BRP greater than 0 in CANBT1 and SMP equals 1 in CANBT3 allows re-synchronization with the majority vote, and thus fixes the issue. The sampling point might have to be slightly advanced for the majority vote to take place within the bit. Therefore, at maximum speed of 1Mbit/s, the sampling point should be at less than 80% (e.g. 75%) for XTAL = 16 MHz or less than 85% (e.g. 80%) for XTAL = 20 MHz. 14. C51 Core Bad Exit of Power-down in X2 Mode When exiting power-down mode by interrupt while CPU is in X2 mode, it leads to bad execution of the first instruction run when CPU restarts. Set the CPU in X1 mode diretly before entering power-down mode. 15. Timer0/1 Extra interrupt. When the Timer0 is in X1 mode and Timer1 in X2 mode and vice versa, extra interrupt may randomly occured for Timer0 or Timer1. Use the same mode for the two timers.. 3

16. EEPROM Lock-up during ISP write Program lock-up can be experienced when using Atmel FLIP software or a custom In system Pogramming tools to write in the internal EEPROM. This problem occurs with clock frequency > 12MHz in X2 mode or 24MHz in X1 mode. Neither the code Flash nor the EEPROM are corrupted by the lock-up. Although the EEPROM cannot be written by the bootloader. This problem does not affect the capability to erase, read and write into the code Flash and the additional bytes with In- System Programming as Atmel FLIP. This problem is bootloader related and doesn t affect the capability for the user to read and write into the EEPROM. This problem is technology dependant. The likelyhood of experiencing the problem is low at Clock frequency > 24 MHz in X1 mode and non-existent below. A reset can be applied to recover from the lock-up. The following process can be done to work around the problem. Start the bootloader - With hardware condition Download a Init EEPROM program in flash memory Start this init EEPROM program - With "start application" command Re-Start the bootloader - With hardware condition Download a Final program in flash memory - With "start application" command C Init EEPROM program example: #define SIZE_EEPROM 12 unsigned char code tab_eep[size_eeprom]={0x11,0x22,0x33,0x44,0x55,0x66,0x77,0x88,0x99,0xaa}; void main (void) { unsigned char xdata * address; unsigned char cpt; address =0x00; for (cpt=0; cpt<size_eeprom; cpt++) 4

{ EECON = 0x02; // enable eeprom access *(address + cpt) = tab_eep[cpt]; EECON = 0x50; EECON = 0xA0; while (EECON&0x01); } } Assembler Init EEPROM program example: SIZE_EEPROM EQU 00Ah CSEG AT 0000H Mov R1, #SIZE_EEPROM Mov DPTR, #0h Load_eeprom: MovEECON, #02h ; set bit EEE for access to the column latches MovA, #Tab_eep Movc A, @A + DPTR Movx @DPTR, A Mov EECON, #050h Mov EECON, #0A0h WAIT_FBUSY: Mov A, EECON AnlA, #001h Xrl A, #001h JzWAIT_FBUSY Inc DPTR Djnz R1, Load_eeprom End_loop: jmp End_loop Tab_eep: DB 012h, 023h, 045h, 067h, 089h, 0ABh, 0CDh, 0EFh 17. Transmission after a 3 bit Intermessage If a Transmit Message Object (MOB) is enabled while the CAN bus is busy with an on going message, the transmitter will wait for the 3-bit Intermission before starting its transmission. This is in full agreement with the CAN recommendation. If the transmitter lost arbitration against another node, two conditions can occur : 5

1. At least one Receive MOB of the chip are programmed to accept the incoming message. In this case, the transmitter will wait for the next 3-bit Intermission to retry its transmission. 2. No Receive MOB of the chip are programmed to accept the incoming message. In this case the transmitter will wait for a 4-bit Intermission to retry its transmission. In this case, any other CAN nodes ready to transmit after a 3-bit Intermission will start transmit before the chip transmitter, even if their messages have lower priority IDs. Always have a Receive MOB enabled ready to accept any incoming messages. Thanks to the implementation of the CAN interface, a Receive MOB must be enable at latest, before the 1 st bit of the DLC field. The Receive MOB status register is written (RXOK if message OK) immediately after the 6th bit of the End of Frame field. This will leave in CAN2.0A mode a minimum 19-bit time delay to respond to the end of message interrupt (RXOK) and re-enable the Receive MOB before the start of the DLC field of the next incoming message. This minimum delay will be 39-bit time in CAN2.0B. See CAN2.0A CAN2.0B frame timings below. CAN2.0A T1 19 bit time minimum T2 CAN2.0B T1 39 bit time minimum T2 implementation The workaround is to have the last MOb (MOb14) as "spy" enabled all the time; it is the MOb of lowest priority : If a Mob other than MOb14 is programmed in receive mode and its acceptance filter matches with the incoming message ID, this Mob will take the message. MOb14 will only take messages than no other MObs will have accepted. MOb14 will need to be re-enabled fast enough to manage back to back frames. The deadline to do this is the beginning of DLC slot of incoming frames as explained above. 6

Minimum code to insert in CAN interrupt routine: interrupt void can_int_handler(void) { if ((CANSIT1 & 0x40) == 0x40 ) /* MOb14 interrupt (SIT14=1) */ { CANPAGE = (0x0E << 4); /* select MOb14 */ CANSTCH = 0x00; /* reset MOb14 status */ CANCONCH = 0x88; /* reception enable */ }...... 18. Timer1 in Mode 1 does not generate Baud rate to UART. } The timer1, when used as a baud rate generator in mode 1 (16 bits counter) for low baud rates, does not generate baud rate to UART. No. 7

Active UART Bootloader Errata List Timer 2 and UART Are Not Stopped Watchdog and Flash API Starting the Bootloader Execution Autobaud False Start Bit Detection Boot Process Compatibility Flash API api_wr_code_page with 0 Data in Length Parameter Field UART Bootloader Errata History Version Number Errata List 1.2 (1.1.2 displayed by FLIP) 1, 2, 3 1.4 (Current) 1, 2, 3, 4,5 UART Bootloader Errata Description 1. Timer 2 and UART Are Not Stopped When the bootloader receives the command Start Application (LJMP 0), the Timer 2 and the UART are not stopped. The application must have in its setup function a reset of Timer 2 and UART. mov SCON, #00h mov T2CON, #00h mov RCAP2L, #00h mov RCAP2H, #00h mov TL2, #00h mov TH2, #00h 2. Watchdog and Flash API Starting the Bootloader Execution When an application call api_start_bootloader or api_start_isp routines while the watchdog is enabled, when the watchdog overflows it will restart the application instead of the bootloader. Set BLJB(=1) before calling the api_start_bootloader or api_start_isp if the watchdog is used. 3. Autobaud False Start Bit Detection UART autobaud sequence does not work in some special UARTs. Some laptops have the UART TX line set to 0 when unused (COM port closed), this results in a false baud rate calculation in the U character. The autobaud sequence checkes for a 0 state (not a falling edge) on the Rx line of the UART microcontroller to detect the start bit of the U synchro character. As this line is 0 by default when COM port is closed, the autobaud routine starts its baudrate calculation at the opening sequence of the UART. A Special Sync can be used with FLIP software. In this case, the open port event and the U sent are dissociated. The user must first open the COM port with the connect button, then reset the hardware and finally push the sync button. 4. Boot Process Compatibility There are some differences between Boot process of bootloader 1.2 and newer versions (see below). 8

Version 1.2: RESET BLJB = 1 BLJB = 0 BLJB Hardware Process No FCON = F0h Software Process Yes Yes BSB = 00h No No SBV = FCh Yes Application Executed User Bootloader Executed Atmel bootloader Executed Version 1.4: RESET BLJB = 1 BLJB = 0 BLJB Hardware Process Software Process FCON = F0h Yes No Yes SBV < FCh No Application Executed User Bootloader Executed Atmel bootloader Executed Use the fuse bit BLJB to start the application in both versions. 5. Flash API api_wr_code_page with 0 Data in Length Parameter Field When the Flash API api_wr_code_page is called with the field nb_data equal 0 then 255 data are written in Flash. Include a test on nb_data before executing api_wr_code_page routine. 9

Active CAN Bootloader Errata List Watchdog and Flash API Starting the Bootloader Execution Start application with Software Security Set CAN Bootloader Errata History Version Number Errata List 1.0.4 1, 2, 3, 4, 5, 6 1.2.0 (Current) 2, 7 CAN Bootloader Errata Description 1. The CAN is Not Stopped When the bootloader receives the command Start Application (LJMP 0), the CAN is not stopped. The application must have in its setup function a reset of CAN macro. mov CANGCON, #00h 2. Watchdog and Flash API Starting the Bootloader Execution When an application call api_start_bootloader or api_start_isp routines while the watchdog is enabled, when the watchdog overflow it will restart the application instead of the bootloader Set BLJB(=0) before calling the api_start_bootloader or api_start_isp if the watchdog is used. 3. Flash API api_wr_code_page with 0 Data in Length Parameter Field When the Flash API api_wr_code_page is called with the field nb_data equals 0 then 255 data are written in Flash. Include a test on nb_data before executing api_wr_code_page routine. 4. Problem to program a hex file less than 16 bytes When we try to program a hex file with a size size less than 16 bytes, some troubles appear depending of the start address. Program with a range address higher than 16 bytes. 5. Unexpected echo after start application command When the command start application (with reset) is received by the CAN bootloader; the bootloader answers with a ramdom CAN frame before starting the application. The FLIP software is not impacted by this CAN frame. 10

6. CRIS Modification not applicable for In-application Usage When the CAN Relocatable Identifier Segment (CRIS) is modified, this modification is not taken into account in the bootloader, when it is started by the application for In-application Programming usage. Use only CRIS=00h or reprogram with a parallel programmer the new CAN bootloader rev 1.2.0 available at http://www.atmel.com. This new bootloader will correct also errata #1, 3, 4, 5, 6. 7. Start application with software security set The start application with or without reset doesn t work if the software security are set. Use the SSB API to secure the device in the application. 11

Atmel Corporation 2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 487-2600 Regional Headquarters Europe Atmel Sarl Route des Arsenaux 41 Case Postale 80 CH-1705 Fribourg Switzerland Tel: (41) 26-426-5555 Fax: (41) 26-426-5500 Asia Room 1219 Chinachem Golden Plaza 77 Mody Road Tsimshatsui East Kowloon Hong Kong Tel: (852) 2721-9778 Fax: (852) 2722-1369 Japan 9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 Japan Tel: (81) 3-3523-3551 Fax: (81) 3-3523-7581 Atmel Operations Memory 2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314 Microcontrollers 2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314 La Chantrerie BP 70602 44306 Nantes Cedex 3, France Tel: (33) 2-40-18-18-18 Fax: (33) 2-40-18-19-60 ASIC/ASSP/Smart Cards Zone Industrielle 13106 Rousset Cedex, France Tel: (33) 4-42-53-60-00 Fax: (33) 4-42-53-60-01 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759 Scottish Enterprise Technology Park Maxwell Building East Kilbride G75 0QR, Scotland Tel: (44) 1355-803-000 Fax: (44) 1355-242-743 RF/Automotive Theresienstrasse 2 Postfach 3535 74025 Heilbronn, Germany Tel: (49) 71-31-67-0 Fax: (49) 71-31-67-2340 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759 Biometrics/Imaging/Hi-Rel MPU/ High Speed Converters/RF Datacom Avenue de Rochepleine BP 123 38521 Saint-Egreve Cedex, France Tel: (33) 4-76-58-30-00 Fax: (33) 4-76-58-34-80 Literature Requests www.atmel.com/literature Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL S TERMS AND CONDI- TIONS OF SALE LOCATED ON ATMEL S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDEN- TAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. Atmel does not make any commitment to update the information contained herein. Unless specifically providedotherwise, Atmel products are not suitable for, and shall not be used in, automotive applications. Atmel s products are not intended, authorized, or warranted for use as components in applications intended to support or sustain life. Atmel Corporation 2006. All rights reserved. Atmel, logo and combinations thereof, and Everywhere You Are are the trademarks or registered trademarks, of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others. Printed on recycled paper.