C5S120 Installation and Connection Guide

Similar documents
USER MANUAL C5S110&120&140. Version: 1.1 Date: Apr., 2018

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Two Door Controller GEN-045

iface Series Installation Guide

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Installation Guide. UHF RFID Integrated Machine: U1000E, U1000F, U2000E, U2000F. Version: 1.0 Date:

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Connecting a Cisco Output Module

Fingerprint Access Control F1. User Manual

F11 Installation Guide. Version: 1.0 Date: Jul. 2010

GENERAL QUICK START GUIDE

SCR100 User Manual. Version:1.1 Date:Dec 2009

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

Connecting a Cisco Reader Module

Quick Start Installation Guide

IPassan Installation guide

Connecting a Cisco Input Module

2M Outdoor Motorized Bullet Camera

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

Operation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

REX F-0-9 Standalone or Access Controller

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

Zodiac FR100 TM INSTALLATION MANUAL

Quick Start Guide. GV-CS1320 Camera Access Controller

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

Outdoor Motorized Dome. Quick Installation Guide 86085A

Access control panel U-Prox IC E (Elevator control)

IEI emerge MicroNode Install and Setup Guide. Contents

ImproX IXP20 Controller INSTALLATION MANUAL

Quick Start Guide. GV-Video Server

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

GV-AS200 Controller. Hardware Installation Guide

Cardax FT Controller 3000

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Falcon SM200 Series Camera

B-33. Hardware and Install Manual. (DC 12V / PoE)

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Digital Keypad Introduction

P6210 PN: 86085A A

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host.

Quick Start Guide. GV-Video Server

Agenda. August 23, 2017 Slide 2

GV-AS Controller. Installation Guide

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

smartentry Wireless Video Doorphone User Manual

2M IR Mini Dome Quick Installation Guide

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

CM-110SK Standalone Keypad Installation Instructions

5.5 AS Layout. GeoVision Technical Handbook 77

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Wiring Instructions v4

Hardware Installation

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Single Door Standalone Access Control User Manual

D4210 PN: 86085A

iclock serial Time & Attendance and Access Control Terminal Installation Instructions

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents

Installation Instructions (KF-2000)

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

WAC-IPMG200 IP Based Access Control System

Suprex RS-485 SPX-7500 Wired Reader-Extender

8~14-Port Managed Ethernet Switch

Outdoor Dome. Mounting on a Tilted Wall with Gang Box (Face Down / Face Forward) Installation Guide. For Models: B81, B84, B85, B /01/13

Installation guide for PR302 v2.0 Rev. E

4K/UHD 4/8-Output HDMI to HDBaseT Distribution Amplifiers

EAP110-Outdoor. Installation Guide. 300Mbps Wireless N Outdoor Access Point

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

Two-door Access Controller

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

How to Install a PowerNet IPBridge

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel

NS1 Connection Unit Guide

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.

S1 Access Control Gateway Datasheet

Amano Nexus Lite Controller INSTALLATION MANUAL

User Manual. Before using this device, read and follow all instructions for safety

PR402 v2.0 Installer Manual Rev.C

NetCommWireless. Quick Start Guide NTC-30 Series - Outdoor WiFi Router

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

Outdoor Hemispheric Mounting on the Ceiling with Gang Box (Face Down)

PR602LCD v1.0 Installer Manual Rev. A

Quick Installation Manual

Installation Guide & User Manual. FR1300 Version: Date: November, 2014

FSM-510G Series Ethernet Management Switch Quick Start Guide

Manual RouterNode

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

Wiring Guide EP.HIO. Version 1.03 Last Updated:

INSTALLATION GUIDE Xpass English Version 2.00 EN XPS V2.00A

Installation Guide. Avigilon ACM Embedded Controller

Transcription:

C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before installation is complete; never carry out installation activities when the system is energized. Check the correctness of cable connection before you energize the system. 2) All peripheral devices must be grounded. 3) The conduits of wires under relay must be matched with metaled conduits, other wires can use PVC conduits. 4) It is strongly recommended that the length of exposed part of any connection cable should not be longer than 4 mm. Professional clamping tools may be used to avoid unintentional contact of exposed wires to avoid short-circuit or communication failure. 5) It is recommended that the control panel be installed at height of 2m above ground, card readers and buttons be installed at height of 1.4m-1.5m above ground. 6) It is not recommended that the electrical lock and control panel use the same power supply. It is recommended that the control panel use the provided access control power supply or PoE, and the electrical lock use an external power supply separately. Description of normal working state: Connect the system to the power supply. If the system works properly, the POWER indicator (red) is lit constantly and the RUN indicator (green) flashes. If the system is communicating, the COMM indicator (yellow) flashes. 2. Components Heat Dissipation Hole State Indicator Box Lock Hole Thread Hole Control Panel Temper Switch Interface Antenna Connector Adapter Panel Box Appearance Panel Box Inside Get the Panel off the track (Remove the set screws) 3. Installation If the provided chassis is used, the control panel has been installed inside the chassis by default. Fix the chassis on the wall, remove the hole plug or get through the thread hole, connect the access control cable, and install other components. Remarks: The control panel has a guide rail on the back. If you need to install the control panel separately without the chassis, you can use the guide rail to fix the control panel. The following figures show how to fix the control panel using the guide rail. Control Panel Guide Rail Thread Hole 1) Remove the hole plug or get through the thread hole 2) Fix the guide rail on the wall 3) Install other components

4. LED Indicators and Wire Illustration 1) Meaning of LED indicators: POWER indicator (red): light always indicates control panel is power on. RUN indicator (green): flashing indicates the system works normally. COMM1 indicator (yellow): flashing indicates the system is communicating with upper-level devices (for example, the PC). COMM2 (yellow): flashing indicates the system is communicating with lower-level devices (for example, readers). WLAN indicator (green): flashing indicates the system is communicating in wireless (WIFI) mode. DOOR indicator (green): flashing indicates a door opening signal (a door is opened). 2) Recommended use of wires: Interface Wire Specification Network cable Maximum length (A) 18AWG*2PIN / 1.5M Wiegand (B) 24AWG*6PIN CAT-5 or above network cable, one way (6PIN, 8PIN, 10PIN for different readers) DC impedance less than 100Ω/KM 100M 18AWG*2PIN+24AWG*2PIN. Electric Lock (C) 18AWG*2PIN for lock connection, / 50M 24AWG*2PIN for door sensor connection. Button (D) 24AWG*2PIN / 100M EXT RS485 (E) 20AWG*2PIN+24AWG*2PIN, 20AWG*2PIN for reader power supply, 24AWG*2PIN for RS485 communication CAT-5 or above network cable, one way DC impedance less than 100Ω/KM. In wire connection, +12V and GND of power supply need to be parallel and use double wires. Share power with control panel: 100M Use independence power supply (connect RS485 signal interface only): 1000M 3) The auxiliary input may be connected to infrared body detectors, fire alarms, or smoke detectors. The auxiliary output may be connected to alarms, cameras or door bells, etc. 4) State Indicators are connected to the chassis, with is power indicator, run status indicator and communication status indicator. 5) PC RS485 indicates the RS485 cable is connected to the PC through this port. The EXT RS485 port can be connected externally to RS485 reader. 6) The USB slot is primarily used for control panel upgrade. For details, see the user manual. State Indicator #1 Door #2 Door Antenna Connector EXT RS485 Wiegand Reader 1 Wiegand Reader 3 Wiegand Reader 2 Wiegand Reader 4 Rotary DIP Switch Ethernet/PoE Interface USB Reset PC RS485 Auxiliary Output Auxiliary Disassembly/ Mains/Battery Abnormality Alarm

5. DIP Switch Settings The 0 F bits of the rotary DIP switch indicate device numbers 1 16 during RS485 communication. (Switch 0 indicates device number 16, switch 1 indicates device number 1, and so on. Switch F indicates device number 15). You can rotate the 0 F bits of the rotary DIP switch to corresponding positions to set device numbers, and then restart the control panel to make the setting take effect. Address numbers cannot be repetitive. 6. Connection Of Lock 1) Control panel provides lock control output interfaces. For NO lock, it is open when power is on, and closed when power is off, so COM and NO interfaces should be used. For NC lock, it is open when power is off, and closed when power is on, so COM and NC interfaces should be used. 2) The default connection mode of the door lock is dry mode. Specifically, the electrical lock uses an external power supply separately, rather than share the power supply for the control panel. 3) Our access controller is powered by standard PoE or access control power. You can choose either of the two power supplies as needed. The two power supplies provide 12V/3A power for only the power consumption of the control panel, Wiegand readers, and output power consumption of RS485 reader. 4) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107 diode (equipped in the package) to prevent the self-inductance EMF affecting the system, do not reverse the polarities. 5) The following figure shows the default lock connection mode. NC Lock Lock Diode Enlarged diagram of lock ports Lock Diode NO Lock Dry mode wiring diagram of lock connecting with external power supply(recommend) 7. RS485 Reader Connection The control panel supports RS485 reader and Wiegand reader (Note: The control panel does not support fingerprint verification of RS485 reader). RS485 reader connection: First of all, set the RS485 address (device number) of the reader by DIP switch or other ways. The RS485 address 1 is for Door 1 IN reader, RS485 address 2 is for Door 1 OUT reader, RS485 address 3 is for Door 2 IN reader, RS485 address 4 is for Door 2 OUT reader, as in the figure below. +12V GND 485B 485A PC 4# Reader 3# Reader 2# Reader 1# Reader TCP/IP Besides, a single EXT RS485 interface can supply maximum 750 ma (12V) current. So the entire current consumption should be less than this max value when the readers share power with the panel. In calculation, please use max current of the reader, and start current is usually more than twice of the normal work current, please consider of this situation.

For example, use the KR502M-RS card reader, the standby current is less than 80mA, the max current is less than 90mA, When the device is start, Instantaneous current can reach 180 ma. As RS485 reader, consider the starting current is bigger, through the EXT RS485 interface can only connect four readers for power supply. So the power of control panel connect only nearest 4 readers. If RS485 reader is connected externally and shares the power supply for the device, it is recommended that the connection between the EXT RS485 port and the reader be no longer than 100m. Otherwise, it is recommended that the reader use a separate power supply. For some of the devices with much greater consumption, we suggest to using the separately power supplies, to make sure the steady operation. 8. Equipment Communication The background PC software is able to communicate with the system according to three protocols (TCP/IP, RS485 and WIFI (optional)) for data exchange and remote management. The communication cable should be as far away from high-voltage lines as possible. Do not keep the communication cable in parallel with power cords or bind them together. 8.1 TCP/IP Communication PC Printer Card Issuer Switch TCP/IP 1# Control Panel 2# Control Panel N# Control Panel For ZKAccess3.5 software: Click [Device] > [Device] > [Add], also you can click [Device] > [Search Device] to search devices which in the network, and directly add from the searching result. 8.2 RS485 Communication Serial Line 1# Control Panel 2# Control Panel 16# Control Panel PC 1) Internationally accepted RVVSP (shielded twisted-pair) wires should be used for communication to effectively avoid interference. 2) RS485 communication wires should be connected by means of bus cascade connection. 3) Considering stability of communication, it is recommended the length of RS485 bus is less than 600m. 4) Up to 16 device numbers can be set because the rotary DIP switch on the control panel has 16 bits. Therefore, a single RS485 bus can be connected to 16 access control panels at most. 5) To enhance the stability of communication when the bus is longer than 300m, connect the provided 120-ohm terminal resistor between the 485A and 485B wires of the first and last control panels respectively.

8.3 Wireless Communication 1) Create a valid connection string using TCP/IP, and make sure that there is available WiFi network. 2) the IP address of the controller (factory default is 192.168.1.201) in the address bar; enter the user name and password (both are admin), and click [Sign In] to access the ZKPanelWeb. Note: 1. Must configure IP address of the controller and Server (PC) in the same network segment 2. When the controller s IP address is unknown, you can obtain the IP through searching device in the software. 3) Click [TCP/IP Settings] to modify the IP address and gateway address; Extended Network Card Setting is set when the controller is connected to TCP/IP reader. For detailed setting methods, please refer to the instructions of TCP/IP reader. 4) Click [WIFI Settings] > [Search] to search the available WiFi. 5) Select available WiFi in the wireless network list and click [Action] (Figure 1), enter the key, and configure DHCP (the IP address and gateway must be in the same network segment as the wireless network IP address), and then click [Confirm]. After the connection is successful, the wireless connection status shows connected (as shown in Figure 2), and the device's WLAN indicator turns green.

figure 1 figure 2 Note: The PC (server) must be on the same network segment as the router (wireless network). 6) Switch network connection in the software. For ZKAccess3.5 software: Select the added C5S control panel on the Device page and click [More ] > [Set up WiFi], as figure 3, set the WIFI parameters of the control panel based on the router parameters. Restart the control panel to make the WIFI settings take effect. figure 3 Note: You must add the C5S control panel to the software through TCP/IP before setting WIFI parameters. Connection through RS485 is not allowed. Of the devices added to the software, only the C5S control panel supports WIFI setting. For details about how to add devices and set WIFI, see the software instructions.