Switches Unlimited Contact: Phone: * Fax:

Similar documents
METERING INSTRUMENTS AND CURRENT TRANSFORMERS 23

Page Page 23-17

Metering instruments and current transformers

DIGITAL LCD MULTIMETERS AND POWER ANALYZERS Graphic LCD or touch screen Remote display Expandable versions.

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

DIGITAL METERING INSTRUMENTS DMG SERIES

Digital metering instruments and current transformers

with Backlight Graphic LCD Screen

Digital multimeters DMG

Expansion modules and accessories

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

E N E R G Y M E T E R S

Page measurement up to 15th order Front optical USB and Wi-Fi communication port for PC, smartphone and tablet connection

Page Page Page ACCESSORIES Communication devices Remote display unit Protective covers Converters Gateway Connecting cables.

Page Backlight graphic display, 128x80 pixels. Optic interface port for programming, data download and diagnostics

Switches Unlimited Contact: Phone: * Fax:

Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9

AUTOMATIC POWER FACTOR CONTROLLERS AND THYRISTOR MODULES 23

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

AND COMMUNICATION MODULES

ENGINE, GENERATOR AND ATS CONTROLLERS. Engine Protection Controllers p18-1

ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL

100% electricity. Automatic transfer switch controllers ATL series

ATS Automatic transfer switches Advanced version

Hot pluggable communication modules

Page CONFIGURATION AND REMOTE CONTROL SOFTWARE Parameter setting Point-by-point monitoring Memory module management.

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

NEW AUTOMATIC P.F. CORRECTION BANKS. MULTImatic. Powerful, versatile and smarter thanks to the new RPC 8BGA Controller QUALITY MADE IN ITALY

ENGINE AND GENERATOR CONTROLLERS

PM800 series. Applications

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

ENERGY AND AUTOMATION

Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9

ENERGY AND AUTOMATION

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

MIC-2 MKII, Multi-instrument DATA SHEET

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

PQM4000 and PQM4000 PQM4000RGW. Class A DIN 192x144 power quality analyzer for CTs. Class A certified in compliance with IEC/EN :2015 Ed.

SOFT STARTERS PLANET -LOGIC

Automatic Power Factor Controllers Thyristor Modules p17-7

Page ATL 610 Management of two power sources. AC and DC power supply. 6 programmable digital inputs. 7 programmable relay outputs

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

AND COMMUNICATION MODULES

MIC-2 Multi-instrument DATA SHEET

METERING INSTRUMENTS DIGITAL MULTIMETERS AND ENERGY METERS NETWORK ANALYZERS DATA CONCENTRATOR COMMUNICATION DEVICES

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

WM20. Power analyzer for three-phase systems. Benefits. Description

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PQM4000 and PQM4000RGW

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

A2000 Multifunctional Power Meter

MW/MVAR Transducer Specifications

100% electricity. Power factor correction components

Power Management System. Multifunction Measuring Instruments

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Electronic Submeter with Advanced WiFi Ethernet Capability

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)

THE NEXT TRANSDUCER GENERATION

EngyVolt RV12 and RV15

Electrical multifunction analysers

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

ABB NETWORK ANALYSER M2M. Quick set-up guide

Multifunction Transducer MT440

Power Meter PowerMonitor 500

For Info: Phone: Fax:

MMT330 Series Moisture and Temperature Transmitters for Oil

DIRIS A-30 Multifunction power metering & monitoring device - PMD

Energy Division. Crompton Instruments Integra 1630 Low Profile Digital Metering System

Energy Management Solutions

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter

Page 5-3. Page 5-2 Page 5-3

Comprehensive Modular Genset Controller

EC 600 Electronic Volume Corrector

DATA SHEET Selectable AC transducer, TAS-331DG

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

CALEC energy master The benchmark in energy measurement

100% electricity. Automatic transfer switch controllers ATL series

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Monitoring various parameters with one power meter!

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

Motor protection relays

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Power Management System. Measuring Devices for Power Distribution

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

The PowerLogic range. Gain energy insight and control

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

Transcription:

Page -10 EERGY S Single phase, three phase with neutral, three phase with or without neutral irect connection or by current transformers MI certified versions Expandable versions. Page -15 T CCETRTRS Energy consumption data storage for network usage Connection up to 14 energy meters equipped with static output Photovoltaic monitoring type Expandable versions. IGIT C MUTIS PWER YZERS Graphic or icon C Version with touch screen Modular and panel mount types Remote display Expandable versions. Page -16 Pages -16 and 17 PRTBE PWER YZERS IP65 casing With built-in USB interface GPRS/GSM communications vailable kits of current clamps and cables. Page -18 to 24 E MESURIG ISTRUMETS Voltmeters, ammeters, frequency meters, cosphi meters and wattmeters. IGIT E MUTIS Basic version, with energy meters, with 2 programmable outputs, for use with generating sets and with data-logger. CURRET TRSFRMERS Primary current: 50-4,000 Secondary current: 5 Solid and split-core types. Page -32

IG ISTRUMETS CURRET TRSFRMERS igital voltmeters, ammeters, wattmeters, frequency meters and cosphi meters igital multimeters and power analyzers, expandable, with graphic C Connection to single, two, three phase systems Ideal for distribution systems, co-generation energy systems, stand-by generating sets and on-board machinery installation High measurement accuracy Totally programmable digital outputs RS485, RS2, USB, Ethernet, Profibus P serial interface for remote control and data-logger. Energy meters SEC. - PGE Single phase... - 10 Single phase, MI certified... - 11 Three phase with or without neutral... - 12 Three phase with neutral, MI certified... - 13 Three phase with or without neutral, UTF certified... - 14 ata concentrator General use... - 15 For photovoltaic control and supervision... - 15 igital metering instruments Modular C multimeters... - 16 Flush mount C multimeters... - 18 Flush mount touch-screen C power analyzers... - 19 Flush mount E measuring instruments... - 20 Flush mount E multimeters... - 22 Modular E measuring instruments... - 26 Modular E multimeters... - 28 Communication devices, protection covers, accessories... - 30 RS2/RS485 converter drive, cables, software, kits of current clamps... - 31 Current transformers... - 32 imensions... - 34 Wiring diagrams... - 36... - 40 EERGY MGEMET

igital metering instruments Installation supervision MV/V transformer room MG 900 + EXP 1031 Energy Quality per E 50160 MG 800 + EXP 1004 Temperature control Primary distribution MG 800 ME 310 (MI) MG 800 MG 700 MG 700 (MCC) M M M M Secondary distribution MG 300 210 200 MG 800 + EXP Process and ambient control ME 310 T2 ME 300 T2 ME 100 T1 ME 110 T1 ME 120 T1 ME C -2

igital metering instruments etworks with software Web browsing of each instrument connected in Ethernet Wi-Fi Tablet, Smartphone SWITCH Ethernet Internet VP EXP 1013 MG 300 + EXM 1013 MG 800-900 + EXP 1013 EXP 1012 MG 800-900 ME C ata concentrator + EXM 1013 8+4 max with EXM 10 Energy meters ME... T1 with pulse outputs Ethernet Server FTP ntenna GSM CX03 SMS, e-mail MG 210 RS485 MK 8+6 max with EXM 10 MG 900 ETH-RS485 EXP 10 15 ETH-RS485 RS485 MG 210 MG 700 MK ME C ata concentrator RS485-3

igital metering instruments Grid quality verification Energy consumption control Quality analysis per E 50160 High versatility Easy and intuitive consulting and configuration. MG series multimeters and ME series energy meters larms Boolean logic ata acquisition of environmental conditions Micro PCs iagnostics and control Protection relays -4

igital metering instruments Photovoltaic installation management C C ➀ ➁ ption for distinct values of import and export energy ME energy meter: EERGY PRUCE ➁ EECTRIC IE ➁ ME energy meter: EERGY CSUME EECTRIC PUSES C/C IVERTER STTUS/RM ME C PV1 data concentrator views: Energy Produced Consumed Exchanged ➀ Self-consuming index C/C inverter alarms, any others. ption for 2 load disconnection by EXM10 01 Enabling / Commands ption for Ethernet connection by EXM10 03 ETHERET Wi-Fi CTRBE S Router Contactors PRIVIEGE S PP: PV VIEW Supervision option remoted by software (see Section 27) ➀ If the distinct values of import and export energy need to be known, a third energy meter should be installed on the in-coming line; the exchanged energy is the difference between import and export energy with the power supplier. ➁ The energy meters can be single or three phase based on the type of installation. -5

igital metering instruments remote control and supervision software Main plant synoptic view etailed pages of each user with status monitoring and command sending View trend lines Harmonic analysis in bar graph and table format larm and event list with upload to text or Excel file ata log consulting with periodical manual or automatic uploading See Section 27 for details. evice parameterising -6

MEU USB interface T igital metering instruments remote control and supervision software Multiclient-server structure and web-based application with multi-language support (including those of East Europe and Far East) nly one software for many VT Electric devices Field equipment Ethernet network WI-FI Multiclient structure with three access levels Visualizzazione trend grafici. Simultaneous management of several channels Interfaced equipment supervision See Section 27 for details. -7

Flush mount version EERGY S - MUTIMESUREMET EERGY S - MUTIMESUREMET Functions / Measurements ME M100 ME M100 T1 ME 100 T1 ME 110 T1 ME 115 T1 ME 120 T1 ME 121 ME 130 ISTTI Connection Single phase irect 32 32 40 40 40 63 63 63 Through CT MV usage Built-in digital outputs 1 1 1 1 1 Pulse Pulse Programmable Programmable Programmable Built-in digital inputs Built-in communication port RS485 Expandible MI certified version Version with UTF certificates Current/Votlage accuracy ±0.5% ctive energy accuracy Class 1 / (IEC/E 62053-21/E 50470-3) Class B egree of protection IP40 MESUREMETS ctive energy Total Partial Reactive energy Total Partial Separate energy count Import - Export Voltage Current Power ctive power ctive power max demand max demand Power factor only Frequency Cos TH (Total Harmonic istortion) etailed hamonic analysis (orders) Page -10/11-10/11-10 -10/11-10/11 EXPSI MUES igital inputs/outputs nalog inputs/outputs Communication ports USB RS2 RS485 Ethernet Ethernet Gateway function GPRS-GSM modem Type of memory -8

Modular version EERGY S - MUTIMESUREMET MUTIS - PWER YZERS ME 300 T2 ME 310 T2 ME 320 MG 200 MG 210 MG 300 MG 600 MG 610 MG 700 MG 800 MG 900 MG 900T Three phase Single / Three phase 63 5 5 5 5 5-1 5-1 5-1 5 5-1 5-1 5-1 2 2 Programmable Programmable 1 1 Programmable Programmable RS485 RS485 RS485 RS485 or RS2 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.2% ±0.5% ±0.5% ±0.5% ±0.2% ±0.2% ±0.2% Class 1 / Class 1 / Class 1 Class 1 Class 2 Class 0.5S Class 1 Class 1 Class 1 Class 0.5S Class 0.5S Class 0.5S Class B Class B IP40 IP40 IP54 IP65 2 to 31 2 to 31 2 to 63 2 to 63-12 to 14-12 -16-17 -18-18 -19 USB USB USB USB USB USB USB RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS485 RS485 RS485 RS485 RS485 RS485 RS485 Ethernet Ethernet Ethernet Ethernet Ethernet Ethernet Ethernet Profibus Profibus (SMS, email, Client FTP), GPRS data connection ata-logger ata-logger ata-logger ata-logger + Energy Quality E 50160-9

Energy meters Single phase, non expandable ME M100 ME 110 T1... ME 115 ME 120 T1... - ME 121 Single phase, expandable rder code escription Qty Wt per Mechanical meter with mechanical display. ME M100 32 direct connection, 1U 1 0.084 ME M100 T1 32 direct connection, 1U 1 0.088 1 pulse output igital meter, with C screen. ME 100 T1 40 direct connection, 1U 1 0.086 1 pulse output, 220-240VC ME 100 T1 120 40 direct connection, 1U 1 0.086 1 pulse output, 110-120VC ME 110 T1 40 direct connection, 1U 1 0.090 1 programmable static output, multi-measurements ❶, 220-240VC ME 110 T1 120 40 direct connection, 1U 1 0.090 1 programmable static output, multi-measurements ❶, 110-120VC igital meter with backlight C screen. ME 115 T1 40 direct connection, 2U, 1 0.090 1 programmable static output, multi-measurements ❷, 220-240VC ME 120 T1 63 direct connection, 2U 1 0.148 1 programmable static output, multi-measurements ❶, 220-240VC ME 120 T1 120 63 direct connection, 2U 1 0.148 1 programmable static output, multi-measurements ❶, 110-120VC ME 121 63 direct connection, 2U, 1 0.148 RS485 interface multi-measurements ❶, 220-240VC rder code escription Qty Wt per igital meter with backlight C screen. ME 130 63 direct connection, 2U, 1 0.148 multi-measurements❶, expandable, 220-240VC General characteristics The energy meters are instruments for energy consumption measurement in single-phase installations with direct connection. perational characteristics ME M... (mechanical display) Rated supply voltage: 0VC -20...+15% irect connection 32 maximum current ctive energy measurements ctive energy accuracy: Class 1 (IEC/E 62053-21) Mechanical meter with 6+1 digit count Flashing E for consumption indication Static pulse output for ME M100 T1 only Modular I 43880 housing, 1 module Sealable terminal blocks, standard supplied IEC degree of protection: IP40 on front; IP20 at terminals. ME 110T1 ME 110 T1 ME 115 T1 ME 120 T1 ME 121 ME 130 ominal supply voltage: 220-240VC for ME T1 - ME 1120/130 110-120VC for ME T1 120 Voltage range: 187-265VC 50/60Hz for ME T1-ME 120/130 93-132VC 60 Hz for ME T1 120 irect connection Maximum current: 40 for ME 100/110 T1, ME 115 T1; 63 for ME 120 T1 and ME 121/130 ctive energy measurement and accuracy: Class 1 (IEC/E 62053-21) Reactive energy measurement and accuracy: Class 2 (IEC/E 62053-) except for ME 115 T1 C meter : With 5+1 digit count for ME 100/110 T1 ; backlight with 6+1 digit count for ME 115/120 T1 and ME 121/130 Metrological E with pulse emission for consumption indication Clearable partial energy measurement except for ME 100/110 T1 ne output: Pulse for ME 100 T1; programmable static for all other types Built-in RS485 port for ME 121 and optional for ME 130; both compatible with Modular housing, 1 module for ME 100/110 T1 ; 2 module for all other types Sealable terminal blocks, standard supplied IEC/U/CS protection degree: IP51 on front; IP20 at terminals. supervision and energy management software See Section 27. ME 130 EXM 10 10 rder code escription ME 130 EXPSI MUES. Inputs and outputs. EXM10 00 2 digital inputs and 2 static outputs, opto-isolated EXM10 01 2 opto-isolated digital inputs and 2 relay outputs 5 250VC EXM10 02 4 opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 pto-isolated USB interface EXM10 11 pto-isolated RS2 interface EXM10 12 pto-isolated RS485 interface EXM10 13 pto-isolated Ethernet interface EXM10 20 pto-isolated RS485 and 2 relay outputs rated 5 250VC Maximum combination EXM series expansion modules See Section 28, page 3. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (File E346886), as Electrical Process Control Equipment - Energy meters, for ME... types. Compliant with standards: IEC/E 61326-1 for ME M... type; E 50470-3, IEC/E 61010-1, U 61010-1, CS C22.2 n 61010-1 for ME... types. ❶ Multi-measurements: - Total and partial active energy - Total and partial reactive energy - Voltage - Current - ctive and reactive power - Power factor - Frequency - Total and partial hour counter - verage active power (calculation on every last 15 minutes) - Maximum demand. MX 1 ❷ Multi-measurements: - Total and partial active energy - ctive power - verage active power (calculation on every last 15 minutes) - Maximum demand. -10 Software and accessories page -30 and 31 Expansion modules page 28-3 imensions page -34 Wiring diagrams page -36 pages -40 amd 41

Energy meters MI Single phase, non expandable, MI certified MI ME 110 T1 MI ME 120 T1 MI rder code escription Qty Wt per igital meter with C display. ME 100 T1 MI 40 direct connection, 1U 1 0.086 1 pulse output, 0VC ME 110 T1 MI 40 direct connection, 1U 1 0.090 1 programmable static output, multi-measerements ❶, 0VC ME 120 T1 MI 63 direct connection, 2U 1 0.148 1 programmable static output, multi-measerements ❶, 0VC General characteristics The ME series energy meters, MI certified, are needed for billing purposes between electricity supplliers and consumers and for energy consumption measurement in directly connected single-phase installations. MI is the Measuring Instruments irective of the European Union; instruments must be certified must be certified accordingly whenever used for monetary transactions in this territory. perational characteristics ominal supply voltage: 0VC Voltage range: 187-264VC 50Hz irect connection Maximum current: 40 for ME 100/110 T1 MI; 63 for ME 120 T1 MI Measurement of 14 electrical parameters for ME 110/120 T1 MI ctive energy measurement and accuracy: Class B (E 50470-3) Reactive energy measurement and accuracy: Class 2 (IEC/E 62053-) C meter: With 5+1 digit count for ME 100/110 T1 MI Backlight with 6+1 digit count for ME 120 T1 MI Metrological E with pulse emission for consumption indication Clearable partial energy measurements in ME 120 T1 MI ne output: pulse for ME 100 T1 MI; programmable static for other types Modular housing, 1 module for ME 100/110 T1 MI; 2 module for ME 120 T1 MI Sealable terminal blocks, standard supplied E protection degree: IP51 on front; IP20 at terminals. Certifications and compliance Certifications obtained: MI Class B, certifications per module B (type tests) and per module (production conformity). Compliant with standards: E 50470-1, E 50470-3. ❶ Multi-measurements: - Total and partial active energy - Total and partial reactive energy - Voltage - Current - ctive and reactive power - Power factor - Frequency - Total and partial hour counter - verage active power (calculation on every last 15 minutes) - Maximum demand. imensions page -34 Wiring diagrams page -36 pages -40-11

Energy meters Three phase with or without neutral, non expandable ME 300 T2 ME 320 Three phase with or without neutral, expandable ME 310 T2 EXM 10 10 rder code escription Qty Wt per igital meter for three phase with neutral. ME 300 T2 63 direct connection, 1 0.360 4U, 2 programmable static outputs, multi-measurements ❶ igital meter for three phase with or without neutral. ME 320 Connection by CT /5 1 0.332 secondary, 4U, RS485 interface, multi-measurements❶ rder code escription Qty Wt per igital meter for three phase with or without neutral. ME 310 T2 Connection by CT /5 1 0.332 secondary, 2 programmable static outputs, 4U, multi-measurements ❶, expandable rder escription code ME 310 T2 EXPSI MUES. Inputs and outputs. EXM10 00 2 digital inputs and 2 static outputs, opto-isolated EXM10 01 2 opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 pto-isolated USB interface EXM10 11 pto-isolated RS2 interface EXM10 12 pto-isolated RS485 interface EXM10 13 Ethernet interface with Web server function EXM10 20 pto-isolated RS485 interface and 2 relay outputs rated 5 250VC EXM10 30 ata storage, clock-calendar (RTC) with backup reserve energy for data logging General characteristics The energy meters are digital meters/analyzers of electric energy for systems with direct three-phase connection or by CT. Expandable with up to 3 EXM series interfaced by infrared beam. perational characteristics ominal supply voltage: 220-240VC (-); 380-415VC (-) for ME 300/310 T2 100-240VC / 110-250VC for ME 320 Voltage range: 187-264VC (-); 3-456VC (-) 50/60Hz for ME 300/310 T2 85-264VC 50/60Hz; 93.5-300VC for ME 320 irect connection 63 for ME 300 T2 Connection by CT /5 for ME 320 T2 and ME 320 ctive energy measurement and accuracy: Class 1 (IEC/E 62053-21) Reactive energy measurement and accuracy: Class 2 (IEC/E 62053-) Voltage measurement range: 20-830VC -; 10-480VC (-) for ME 320 C multifunction meter Metrological E with pulse emission for consumption indication Clearable partial active energy measurements 1 programmable digital input except ME 320 2 programmable static outputs except ME 320 Built-in RS485 port for ME 320 and optional for ME 310 T2; compatible with software ptic interface for EXM series expansion modules with ME 310 T2 Modular housing, 4 module Sealable terminal blocks, standard supplied IEC/U/CS degree of protection: IP51 on front; IP20 at terminals. supervision and energy management software See Section 27. EXM series expansion modules See Section 28, page 3. Certifications and compliance Certifications obtained: EC for all; U isted for US and Canada (cuus File E93601), as uxiliary evices, Multimeters for ME 320. Compliant with standards: E 50740-3, IEC/E 61010-1, U508,CS C22.2 n 14. ❶ Multi-measurements: - Total and partial active energy - Total and partial reactive energy - Voltage - Current - ctive and reactive power - Power factor - Frequency - Total and partial hour counter - verage active power (calculation on every last 15 minutes) - Maximum demand. Maximum combination MX 3-12 Software and accessories page -30 and 31 Expansion modules page 28-3 imensions page -34 Wiring diagrams page -36 page -42

Energy meters MI Three phase with neutral, non expandable, MI certified MI ME 300 T2 MI Three phase with or without neutral, expandable, MI certified MI ME 310 T2 MI EXM 10 10 rder code escription Qty Wt per igital meter for three phase with neutral. ME 300 T2 MI 63 direct connection, 4U 1 0.360 2 programmable static outputs, non expandable, multi-measurements❶ rder code escription Qty Wt per igital meter for three phase with or without neutral. ME 310 T2 MI Connection by CT /5 1 0.332 secondary, 2 programmable static outputs, 4U, multi-measurements ❶, expandable rder escription code ME 310 T2 MI EXPSI MUES. Inputs and outputs. EXM10 00 2 digital inputs and 2 static outputs, opto-isolated EXM10 01 2 opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 pto-isolated USB interface EXM10 11 pto-isolated RS2 interface EXM10 12 pto-isolated RS485 interface EXM10 13 Ethernet interface with Web server function EXM10 20 pto-isolated RS485 interface and 2 relay outputs rated 5 250VC EXM10 30 ata storage, clock-calendar (RTC) with backup reserve energy for data logging Maximum combination General characteristics The ME series energy meters, MI certified, are needed for billing purposes between electricity suppliers and consumers and for energy consumption measurement in directly or CT connected three-phase installations. Expandable with up to 3 EXM series interfaced by infrared beam. perational characteristics ominal supply voltage: 0VC (-); 400VC (-) Voltage range: 187-264VC (-); 3-456VC (-) 50Hz irect connection 63 for ME 300 T2 Connection by CT /5 for ME 320 T2 ctive energy measurement and accuracy: Class B (E 50470-3) Reactive energy measurement and accuracy: Class 2 (IEC/E 62053-) C multifunction meter Metrological E with pulse emission for consumption indication Clearable partial energy measurements 1 programmable digital input 2 programmable static outputs ptic interface for EXM series expansion modules with ME 310 T2 MI compatible with software Modular housing 4 module Sealable terminal blocks, standard supplied E protection degree: IP51 on front; IP20 at terminals. supervision and energy management software See Section 27. EXM series expansion modules See Section 28, page 3. Certifications and compliance Certifications obtained: MI Class B, certifications per module B (type tests) and per module (production conformity). Compliant with standards: E 50470-1, E 50470-3. ❶ Multi-measurements: - Total and partial active energy - Total and partial reactive energy - Voltage - Current - ctive and reactive power - Power factor - Frequency - Total and partial hour counter - verage active power (calculation on every last 15 minutes) - Maximum demand. MX 3 Software and accessories page -30 and 31 Expansion modules page 28-3 imensions page -34 Wiring diagrams page -36 page -42-13

Energy meters MI With UTF certificates Three phase with or without neutral, MI certified ME 300 F Starter kits ME 310 F... EXM 10 10 rder code escription Qty Wt per igital meter for three phase with neutral, complete with UTF certificates for installations in Italy. ME 300 F MI certified type, 63 1 0.360 direct connection, 4U, 2 programmable static outputs, non expandable, multi-measurements, complete with UTF certificate Starter kits with digital MI certified meter 4U, expandable for three phase with or without neutral and 3 current transformers, 0.5S class, all with UTF certificates for installations in Italy. ME 310 F060 Composed of one 1 2.100 ME310T2MI and n 3 transformers M5T0060 ME 310 F080 Composed of one 1 2.200 ME310T2MI and n 3 transformers M5T0080 ME 310 F100 Composed of one 1 1.900 ME310T2MI and n 3 transformers M5T0100 ME 310 F150 Composed of one 1 1.900 ME310T2MI and n 3 transformers M5T0150 ME 310 F200 Composed of one 1 1.900 ME310T2MI and n 3 transformers M5T0200 ME 310 F250 Composed of one 1 1.900 ME310T2MI and n 3 transformers M5T0250 ME 310 F300 Composed of one 1 1.900 ME310T2MI and n 3 transformers M5T0300 TE: ther starter kits are available with 3 CTs up to 1600. Consult Customer Service for information; see contact details on inside front cover. rder code escription ME 310 F EXPSI MUES. Inputs and outputs. EXM10 00 2 digital inputs and 2 static outputs, opto-isolated EXM10 01 2 opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 pto-isolated USB interface EXM10 11 pto-isolated RS2 interface EXM10 12 pto-isolated RS485 interface EXM10 13 pto-isolated Ethernet interface EXM10 20 pto-isolated RS485 and 2 relay outputs rated 5 250VC Maximum combination General characteristics The ME series energy meters, MI certified, are needed for billing purposes between electricity suppliers and consumers and for energy consumption measurement in directly or CT connected three-phase installations. Expandable with up to 3 EXM series expansion modules interfaced by infrared beam. MI is the Measuring Instruments irective of the European Union; instruments must be certified accordingly whenever used for monetary transactions in this territory. The UTF certificate is required for revenue tax purposes by Italian authorities when equipment is part of generating electricity installations (e.g. solar, wind) and there is electricity exchange with the power grid. perational characteristics ME 300 F and ME 310 T2 MI of starter kits ominal supply voltage: 0VC (-); 400VC (-) Voltage range: 187-264VC (-); 3-456VC (-) 50Hz irect connection 63 for ME 300 F Connection by CT /5, standard supplied, for ME 320 T2 MI ctive energy measurement and accuracy: Class B (E 50470-3) Reactive energy measurement and accuracy: Class 2 (IEC/E 62053-) C multifunction meter Metrological E with pulse emission for consumption indication Clearable partial energy measurements 1 programmable digital input 2 programmable static outputs ptic interface for EXM series expansion modules with ME 310 T2 MI compatible with software Modular housing 4 module Sealable terminal blocks, standard supplied E protection degree: IP51 on front; IP20 at terminals. Multi-measurements Total and partial active energy Total and partial reactive energy Voltage Current ctive and reactive power Power Factor Frequency Total and partial hour counter verage active power (calculation on every last 15 minutes) Maximum demand. M5T CURRET TRSFRMERS of starter kits perating frequency: 50-60Hz Secondary output current: 5 Class 0.5S burden verload withstand: 120% Ipn Rated insulation voltage Ui: 720V Rated short time thermal current Ith: 40-60Ipn for 1 second Rated dynamic current Idyn: 2.5Ith for 1 second Insulation (dry type): class E For Ø28mm/1.1 cable For 21.5x21.5mm/0.85x0.85, 26x26mm/1.02x1.02, 31.5x31.5mm/1.24x1.24 busbars Screw fixing terminals Standard supplied sealable terminal covers and fixing elements E degree of protection: IP30. supervision and energy management software See Section 27. EXM series expansion modules See Section 28, page 3. MX 3 Certifications and compliance Certifications obtained: MI Class B, certifications per module B (type tests) and per module (production conformity) for ME 300 F and ME 310F energy meters. UTF certificates for the ME 300F and for each component of the starter kits are standard supplied. Compliant with standards: E 50470-1, E 50470-3 for ME 300F and ME 310 T2 MI; IEC/E 60044-1 for M5T -14 Software and accessories page -30 and 31 Expansion modules page 28-3 imensions page -34 and 35 Wiring diagrams page -36 page -42

ata concentrators Expandable rder code escription Qty Wt per ata concentrator for general use. ME C With 8 programmable 1 0.337 digital inputs, 4U, expandable, RS485 port, for data collection+pulse count from MEM100T1 and ME ❶, expandable ata concentrator for photovoltaic applications. ME C PV1 Programmed for 1 0.340 ME C - ME C PV1 installation control and data collection+pulse count from two ME❶ minimum, 4U, RS485 port, expandable ME KIT C PV1100 Starter kit composed 1 0.515 of one data concentrator MECPV1 and two energy meters ME110T1 ❶ Use with ME110T1, ME115T1, ME120T1, ME300T2 and ME310T2. General characteristics MEC is equipped with 8 inputs, which can be increased up to a maximum of 14 and allows to indirectly interface devices without communication as long as they have at least one pulse output. It is capable of pulse counting that come in from the outputs of meters for energy, water, gas and other types of consumption: ll data is viewed on its display or can also be available for PCs through its built-in RS485 interface using Synergy (STIIZZT) software. It can be expanded with up to 3 EXM series modules by optic interface. With the programmable functions, average values can be determined for instantaneous quantities, such as power, speed, production rate, gas and water consumption, etc. MECPV1 is specific for the monitoring of solar installations and needs to be connected to at least two ME meters (single or three phase). The user can avail of data, such as energy produced by the generating installation, energy consumed by loads as well as exchanged energy (difference between import and export energy) with the power supplier. It is already programmed to automatically calculate the selfconsuming index, mean power values, production (total and partial values) and the operating status of the C/C inverter, if it is equipped with digital outputs. In addition, it can be customised by the user for load supervision, using the EXM series expansion modules, according to the defined logics and on the basis of the energy available. ME KIT C PV1100 EXM 10 10 rder code escription ME C ME C PV1 EXPSI MUES. Inputs and outputs. EXM10 00 2 digital inputs and 2 static outputs, opto-isolated EXM10 01 2 opto-isolated digital inputs and 2 relay outputs rated 5 250VC EXM10 02 4 opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 pto-isolated USB interface EXM10 11 pto-isolated RS2 interface EXM10 12 pto-isolated RS485 interface EXM10 13 Ethernet interface with Web server function EXM10 20 EXM10 30 pto-isolated RS485 interface and 2 relay outputs, rated 5 250VC ata storage, clock-calendar (RTC) with backup reserve energy for data logging perational characteristics ominal supply voltage: 110-240VC / 110-250VC Voltage range: 85-264VC / 93.5-300VC Backlight graphic C 8 inputs, expandable with EXM modules up to 14 Built-in RS485 communication port Modbus-RTU, SCII and TCP communication protocol Multifunction display Clearable total and partial counters for each channel Programmable general counters Calculation of derivative average values Mathematical operations among counters Modular housing, 4 module IEC degree of protection: IP40 on front; IP20 at terminals. supervision and energy management software See Section 27. EXM series expansion modules See Section 28, page 3. Certifications and compliance Certifications obtained: EC for all; U listed for US and Canada (cuus File E346886), as Electrical Process Control Equipment ata concentrator for MEC; pending for MECPV1 and MEKITCPV1100. Maximum combination MX 3 Software and accessories page -30 and 31 Expansion modules page 28-3 imensions page -34 Wiring diagrams page -36 page -43-15

igital measuring instruments. Starter kits Modular C multimeters non expandable MG 200 - MG 210 rder escription Qty Wt code per MG 200 Graphic 128x80 pixel C, 1 0.294 auxiliary supply 100-240VC/110-250VC. Multilanguage: Italian, English, French, Spanish and Portuguese MG 200 01 Graphic 128x80 pixel C, 1 0.294 auxiliary supply 100-240VC/110-250VC. Multilanguage: English, Czech, Polish, German and Russian MG 210 Graphic 128x80 pixel C, 1 0.300 RS485 port, auxiliary supply 100-240VC/110-250VC. Multilanguage: Italian, English, French, Spanish and Portuguese MG 210 01 Graphic 128x80 pixel C, 1 0.300 RS485 port, auxiliary supply 100-240VC/110-250VC. Multilanguage: English, Czech, Polish, German and Russian Starter kits rder code escription Qty Wt per MG KIT 200 150 MG KIT 200 060 Composed of one MG200 1 1.035 multimeter and n 3 CTs 60/5 for Ø22mm/0.87 cable MG KIT 200 080 Composed of one MG200 1 1.035 multimeter and n 3 CTs 80/5 for Ø22mm/0.87 cable MG KIT 200 100 Composed of one MG200 1 1.035 multimeter and n 3 CTs 100/5 for Ø22mm/0.87 cable MG KIT 200 150 Composed of one MG200 1 0.856 multimeter and n 3 CTs 150/5 for Ømm/0.91 cable MG KIT 200 200 Composed of one MG200 1 0.856 multimeter and n 3 CTs 200/5 for Ømm/0.91 cable MG KIT 200 250 Composed of one MG200 1 0.856 multimeter and n 3 CTs 250/5 for Ømm/0.91 cable General characteristics MG 200... and MG 210 digital multimeters are available with a modular housing, 4 module size, and are equipped with a graphic backlight C capable of providing extremely clear, intuitive and flexible viewing of all electrical parameters of an installation. Very accurate measurements combined with their extreme compactness provide an ideal solution for every type of application. The MG 210 version is supplied with RS485 opto-isolated built-in interface. Main measurements and functions include: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values P.F.: Power Factor per phase and total Frequency of measured voltage value HIGH-W-VERGE value functions of all measurements Maximum demand of power and current values Total harmonic distortion (TH) of voltage and current values Energy meters for active, reactive and apparent values Hour counter for programmable total and partial hours. perational characteristics MG200 - MG210 uxiliary supply voltage range: 85-264VC / 93.5-300VC Voltage measurement range: 20-830VC phase-to-phase 10-480VC phase-neutral Usage in medium and high-voltage systems with voltage transformers Rated input current: With external CT /5 Current measurement range with CT up to 10,000 Frequency measurement range: 45-66Hz True RMS measurements for voltage and current values ccuracy: Voltage: ±0.5% (50-830VC) Current: ±0.5% (0.1-1.1 In) Power: ±1% f.s. Frequency: 0.05% ctive energy: Class 1 (IEC/E 62053-21) Reactive energy: Class 2 (IEC/E 62053-) on-volatile memory for data storage Communication protocol Modbus-RTU and SCII for MG 210 only Programming and remote control by software for MG 210 only; compatible with software Modular housing, 4 module IEC protection degree: IP40 on front; IP20 at terminals. CURRET TRSFRMERS (CTs) of starter kits perating frequency: 50-60Hz Secondary output current: 5 Class 1 burden verload withstand: 120% Ipn Rated insulation voltage Ui: 720V Rated short time thermal current Ith: 40-60Ipn for 1 second Rated dynamic current Idyn: 2.5Ith for 1 second Insulation (dry type): class E Faston terminals Standard supplied fixing elements IEC degree of protection: IP30. supervision and energy management software See Section 27. Certifications and compliance Certifications obtained: EC for all; U isted for US and Canada (cuus - File E93601) as uxiliary evices - Multimeter for MG200/210 types. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-4, U508, CS C22.2 n 14 for MG200/210 ; IEC/E 60044-1 for transformers of starter kits. -16 Software and accessories pages -30 and 31 imensions page -34 Wiring diagrams page -37 page -44

igital measuring instruments Modular C multimeters expandable MG 300 EXM 10 10 rder escription Qty Wt code per MG 300 Graphic 128x80 pixel C, 1 0.320 harmonic analysis, auxiliary supply 100-240VC/110-250VC. Multilanguage: Italian, English, French, Spanish and Portuguese MG 300 01 Graphic 128x80 pixel C, 1 0.320 harmonic analysis, auxiliary supply 100-240VC/110-250VC. Multilanguage: English, Czech, Polish, German and Russian rder escription code MG 300 EXPSI MUES. Inputs and outputs. EXM10 00 2 digital inputs and 2 static outputs, opto-isolated EXM10 01 2 opto-isolated digital inputs and 2 relay outputs rated 5 250VC EXM10 02 4 opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXM10 10 pto-isolated USB interface EXM10 11 pto-isolated RS2 interface EXM10 12 pto-isolated RS485 interface EXM10 13 Ethernet interface with Web server function EXM10 20 pto-isolated RS485 interface and 2 relay outputs rated 5 250VC EXM10 30 ata storage, clock-calendar (RTC) with backup battery for data logging Maximum combination MX 3 General characteristics MG300 digital multimeters are available with a modular housing, 4 module size, and are equipped with a graphic backlight C capable of providing extremely clear, intuitive and flexible viewing of all electrical parameters of a system. The very accurate measurements combined with their extreme compactness provide an ideal solution for every type of application. Expandable with up to 3 EXM series modules interfaced by infrared beam. Main measurements and functions include: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values P.F.: Power Factor per phase and total Frequency of measured voltage value HIGH-W-VERGE value functions for all measuements Maximum demand of power and current values Voltage and current asymmetry Total harmonic distortion (TH) of voltage and current values Harmonic analysis of voltage and current up to 31 order Energy meters for active, reactive, apparent partial and total values, programmable tariff functions Hour counter for programmable total and partial hours Pulse counter for general use: consumption pulse counting for water, gas, etc. with expansion module only. perational characteristics uxiliary supply voltage range: 85-264VC / 93.5-300VC Voltage measurement range: 20-830VC phase-to-phase 10-480VC phase-neutral Usage in medium and high-voltage systems with voltage transformers Rated input current: With external CT, 5 or 1 Current measurement range with CT up to 10,000 Frequency measurement range: 45-66Hz True RMS measurements for voltage and current values ccuracy: Voltage: ±0.2% (50-830VC) Current: ±0.2% (0.1-1.1 In) Power: ±0.5% f.s. Power factor: ±0.5% Frequency: 0.05% ctive energy: Class 0.5S (IEC/E 62053-22) Reactive energy: Class 2 (IEC/E 62053-) on-volatile memory for data storage Communication protocol Modbus - RTU, SCII and TCP (only with communication expansion modules) Programming and remote control by software (only with communication expansion modules); compatible with software Modular housing, 4 module IEC protection degree: IP40 on front; IP20 at terminals. supervision and energy management software See Section 27. EXM series expansion modules See Section 28, page 3. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices - Multimeters. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-4, U508, CS C22.2 n 14. Software and accessories pages -30 and 31 Expansion modules page 28-3 imensions page -34 Wiring diagrams page -37 page -44-17

igital measuring instruments Flush mount C multimeters, expandable MG 600 - MG 610 MG 700 - MG 800... MG M3 800 01 EXP 10... rder escription Qty Wt code per MG 600 Backlight icon C, 1 0.300 72x46mmm/2.8x1.8, auxiliary supply 100-400VC / 120-250VC, front optical port MG 610 Backlight icon C, 1 0.350 72x46mmm/2.8x1.8, auxiliary supply 100-400VC / 120-250VC, front optical port and RS485 port MG 700 Graphic 128x80 pixel C, 1 0.510 auxiliary supply 100-440VC/110-250VC. Multilanguage: Italian, English, French, Spanish and Portuguese MG 700 01 Graphic 128x80 pixel C, 1 0.510 auxiliary supply 100-440VC/110-250VC. Multilanguage: English, Czech, Polish, German and Russian MG 800 Graphic 128x80 pixel C, 1 0.510 harmonic analysis, auxiliary supply 100-440VC/110-250VC. Multilanguage: Italian, English, French, Spanish and Portuguese MG 800 01 Graphic 128x80 pixel C, 1 0.510 harmonic analysis, auxiliary supply 100-440VC/110-250VC. Multilanguage: English, Czech, Polish, German and Russian MG 800 048 Graphic 128x80 pixel C, 1 0.520 with harmonic analysis, auxiliary supply 12-24-48VC MG M3 800 01 MG 800 portable unit in 1 3.300 M3 case, prewired, for mobile applications, with USB port, without external cable (see page -31) rder escription code MG 600/610, MG 700 MG 800 EXPSI MUES Inputs and outputs. EXP10 00 4 opto-isolated digital inputs EXP10 01 4 opto-isolated static outputs EXP10 02 2 digital inputs and 2 static outputs, opto-isolated EXP10 03 2 relay outputs rated 5 250VC EXP10 04 2 opto-isolated analog inputs 0/4-20m or PT100 or 0-10V or 0...±5V for MG 800 EXP10 05 2 opto-isolated analog outputs 0/4-20m or 0-10V or 0...±5V for MG 800 EXP10 08 2 opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXP10 10 pto-isolated USB interface EXP10 11 pto-isolated RS2 interface EXP10 12 pto-isolated RS485 interface EXP10 13 pto-isolated Ethernet interface with web server function for MG 800 EXP10 14 pto-isolated Profibus-P interface for MG 800 EXP10 30 ata storage, clock-calendar (RTC) with backup reserve energy for data logging for MG 800 General characteristics MG 600, MG 610, MG 700 and MG 800 digital multimeters are capable of viewing the measurements with high accuracy on the wide graphic C, which allow to control energy distribution networks. They are available with a flush-mount housing, 96x96mm/3.78x3.78 size, and expansion slots to fit plug-in expansion modules (1 for MG 600/610 and 4 for MG 700/800) suitable for numerous applications. The main features include an extended power supply voltage range, high measurement accuracy, expandability and graphic interactive interface for simple use. Main measurements and functions include: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values P.F.: Power Factor per phase and total Frequency of measured voltage value HIGH-W-VERGE value functions for all measurements Maximum demand of power and current values Voltage and current asymmetry Total harmonic distortion (TH): voltage and current Harmonic analysis of voltage and current up to the 31 order with MG 800 only Energy meters for active, reactive, apparent partial and total values with programmable tariff functions Hour counter for programmable total and partial hours Pulse counter for general use: consumption pulse counting for water, gas, etc., with expansion module only. perational characteristics uxiliary supply voltage range: 100-400VC / 120-250VC for MG 600/610 90-484VC / 93.5-300VC for MG 700/800 9-70VC for MG 800 048 Voltage measurement range: 50-720VC for MG600/610 20-830VC - / 10-480VC - for MG 700/800 Usage in medium and high voltage systems with voltage transformers Rated input current: By external CT 5 for MG 700; 1 or 5 for MG 600/610 and MG 800 Frequency measurement range: 45-66Hz True RMS measurements: for voltage and current Measurement accuracy for MG 600/610-MG 700: Voltage: ±0.5% (50-720VC MG 600/610; 50-830VC MG 700) Current: ±0.5% (0.1-1.1In) Power: ±1% f.s. Frequency: ±0.05% ctive energy: Classe 1 (IEC/E 62053-22) Reactive energy: Class 2 (IEC/E 62053-) Measurement accuracy for MG 800 : Voltage: ±0.2% (50-830VC) Current: ±0.2% (0.1-1.1In) Power: ±0.5% f.s. Power factor: ±0.5% Frequency: ±0.05% ctive energy: Classe 0.5S (IEC/E 62053-22) Reactive energy: Class 2 (IEC/E 62053-) on-volatile memory for data storage Communication protocol Modbus-RTU, SCII and TCP Compatible with software Flush-mount housing 96x96mm/3.78x3.78 IEC degree of protection: n front IP54 MG600/610; IP65 all others. ll IP20 at terminals verall M3 case dimensions: See page 4-17. supervision and energy management software See Section 27. EXP series expansion modules See Section 28, page 2. Certifications and compliance Certifications obtained: EC for all except MGM380001; U listed for US and Canada (cuus File E93601), as uxiliary evices Multimeters for MG types pending for MG600/610 and excluding MGM380001. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U508, CS C22-2 n 14. -18 Software and accessories pages -30 and 31 Expansion modules page 28-2 imensions page -34 Wiring diagrams page -37 page -45

igital measuring instruments Flush mount C touchscreen power analyzers, expandable MG 900... MG M3 900 01 MG 900T... MG 900R EXP 10... rder escription Qty Wt code per MG 900 Graphic 128x112 pixel 1 0.566 touch-screen C, harmonic analysis, 4 current channels, (neutral meas.) auxiliary supply 100-440VC/ 110-250VC. Multilanguage: Italian, English, French, Spanish and Portuguese MG 900 01 Graphic 128x112 pixel 1 0.566 touch-screen C, harmonic analysis, 4 current channels, (neutral meas.) auxiliary supply 100-440VC/ 110-250VC. Multilanguage: English, Czech, Polish, German and Russian MG M3 900 01 MG 900 portable unit in 1 3.400 M3 case, prewired for mobile applications, with USB port, without external cables (see page -31) MG 900 048 Graphic 128x112 pixel 1 0.580 touch-screen C, harmonic analysis, auxiliary supply 12-24-48VC MG 900T Measurement transducer, 1 0.570 harmonic analysis, 4 channels, auxiliary supply 100-440VC/110-250VC, RS2/RS485 ports ❶ MG 900T 048 Measurement transducer, 1 0.590 harmonic analysis, 4 channels, auxiliary supply 12-24-48VC, RS2/RS485 ports ❶ Remote display for MG 900T... MG 900R Graphic 128x112 pixel touch 1 0.396 screen C, with 3m/9.8ft long connecting cable ❷ ❶ o simultaneous operations of serial ports; only one port can be used at a time. Consult instructions manual for details. ❷ irect link to MG 900T dedicated port: powered directly by MG 900T. rder escription code MG 900 and MG 900 T EXPSI MUES. Inputs and outputs. EXP10 00 4 opto-isolated digital inputs EXP10 01 4 opto-isolated static outputs EXP10 02 2 digital inputs and 2 static outputs, opto-isolated EXP10 03 2 relay outputs rated 5 250VC EXP10 04 2 opto-isolated analog inputs 0/4-20m or PT100 or 0-10V or 0...±5V EXP10 05 2 opto-isolated analog outputs 0/4-20m or 0-10V or 0...±5V EXP10 08 2 opto-isolated digital inputs and 2 relay outputs rated 5 250VC Communication ports. EXP10 10 pto-isolated USB interface EXP10 11 pto-isolated RS2 interface EXP10 12 pto-isolated RS485 interface EXP10 13 pto-isolated Ethernet interface with Web server function EXP10 14 pto-isolated Profibus-P interface EXP10 15 EXP10 30 GPRS/GSM modem ata storage, clock-calendar (RTC) with backup reserve energy for data logging EXP10 31 ata storage, with Energy Quality (E 50160), clock-calendar (RTC) with backup reserve energy for data logging General characteristics MG 900... expandable digital power analyzers are available with a flush-mount housing, 96x96mm/3.78x3.78 size. The wide graphic touch screen display provides extremely simple interacting between the device and the user. The high performance of the power analyzers gives very accurate measurements and can control energy distribution networks, to detect and prevent energy problems which could compromise quality and supply. The main features include an extensive power supply voltage range, high measurement accuracy, expandability up to 4 plug in expansion modules. There also is available the MG 900T measurement transducer which can be used with the MG 900R remote display. The MG 900T, without display, is arranged for mounting inside the panel board, on 35mm I rail, and is an ideal solution for installations where the measurements of various multimeters must be remotely viewed. The MG 900R remote display connected to the MG 900T transducer can display the measurements on the panel front while power connections remain inside the panel. Main measurements and functions include: Voltage: phase, phase-neutral and ground neutral-earth Supply voltage value for the C supply types only Current: phase values eutral current calculated and true values Power: apparent, active and reactive phase and total values P.F.: Power Factor per phase and total Cos per phase and total Frequency of measured voltage value Voltage and current asymmetry Total harmonic distortion (TH) of voltage and current Harmonic analysis of voltage and current up to the 63 order HIGH-W-VERGE value functions for all measurements Maximum demand of power and current values Energy meters for active, reactive, apparent partial and total values with programmable tariff functions Hour counter for programmable total and partial hours Pulse counter for general use: consumption pulse counting for water, gas, etc., with expansion module only Energy quality analysis to E 50160 with expansion module only. perational characteristics uxiliary supply voltage range: 90-484VC / 93.5-300VC for MG 900 and MG 900T; 9-70VC for MG 900 048 and MG 900T 048 Voltage measurement range: 20-830VC phase-to-phase 10-480VC phase-neutral Usage in medium and high-voltage systems with voltage transformers Rated input current: 5 or 1 by CT up to 10,000 Current measurement range: 0.01-10 or 0.002-1.2 Frequency measurement range: 45-66Hz / 360-440Hz True RMS measurements for voltage and current values ccuracy: Voltage: ±0.2% (50-830VC) Current: ±0.2% (0.1-1.1In) Power: ±0.5% f.s. Power factor: ±0.5% Frequency: ±0.05% ctive energy: Class 0.5S (IEC/E 62053-22) Reactive energy: Class 2 (IEC/E 62053-) on-volatile memory for data and event (last 100) storage Communication protocol Modbus-RTU, SCII and TCP with communication expansion modules only Programming and remote control by software with communication expansion modules only; compatible Housing: Flush mount 96x96mm/3.78x3.78 for MG900... and MG 900R; 35mm I rail (IEC/E 60715) fixing for MG 900T IEC protection degree: IP65 on front for MG 900... and MG 900R; IP20 at terminals for MG 900... - MG 900T. supervision and energy management software See Section 27. EXP series expansion modules See Section 28, page 2. Certifications and compliance Certifications obtained: EC for all except MG M3...; U isted, for US and Canada (cuus - File E93601), as uxiliary evices-multimeters for all except MG M3... Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U 508, CS C22.2 n 14. Software and accessories pages -30 and 31 Expansion modules page 28-2 imensions page -34 Wiring diagrams page -37 page -45-19

igital measuring instruments Flush-mount E instruments single phase non expandable MK 0... rder isplayed Relay Qty Wt code measurements output per n n Voltmeter. MK 00 1 voltage value 1 0.290 MK 00 R1❷ 1 max voltage value 1 min voltage value 1 1 0.3 mmeter. MK 01 1 current value 1 0.290 MK 01 R1❷ 1 max current value 1 min current value 1 1 0.3 Voltmeter or ammeter. MK 02❶ 1 voltage or 1 0.290 current value 1 maximum voltage or current value 1 minimum voltage or current value Frequency meter. MK 03 1 frequency value 1 0.290 MK 03 R1❷ 1 max frequency value 1 1 min frequency value 1 0.3 Cosphi meter. MK 04 1 cosphi value 1 0.290 MK 04 R1❷ 1 power factor value 1 1 0.3 ❶ The MK02 can operate as a voltmeter or ammeter. It is duly equipped with two front plates (V and ) which must be fitted by the user depending on which instrument is required and on the wiring scheme used. ❷ Relay output for control and protection functions. General characteristics The MK 0... instruments are available with flush-mount housing, 96x48mm/3.78x1.9 size. Measurements are True RMS values and provide for reliable operation even in presence of harmonics. perational characteristics uxiliary supply voltage: 220-240VC standard; 24VC, 110-127VC or 380-415C type on request perating frequency: 50-60Hz True RMS measurements HIGH and W measurement storage 1 relay output with 1 changeover contact (SPT) for MK...R1 only Housing: Flush mount 96x48mm/3.78x1.9 Terminals: 4mm 2 IEC protection degree: IP54 on front; IP20 at terminals. MK 00 - MK 00 R1 Voltage measurement range: 15-660VC perating frequency range: 45-65Hz Programmable VT ratio: 1.00-500.00 ccuracy: ±0.25% f.s. ±1 digit MK 01 - MK 01 R1 Current measurement range: 0.05-5.75 perating frequency range: 45-65Hz Programmable CT ratio: 5-10,000 ccuracy: ±0.5% f.s. ±1 digit MK 02 Voltage measurement range: 15-660VC Current measurement range: 0.05-5.75 perating frequency range: 45-65Hz Programmable VT ratio: 1.00-500.00 Programmable CT ratio: FF/5-10,000 ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit MK 03 - MK 03 R1 Measurement input: 15-660VC Frequency measurement range: 15-65Hz ccuracy: ±1 digit MK 04 - MK 04 R1 Cosphi measurement error: ±0.5 ±1 digit Cosphi measurement in 4 quadrants ccuracy: ±1 ±1 digit Control and protection functions MK 00 R1 Voltage loss or failure: FF/5-85% Maximum voltage: FF/102-120% Minimum voltage: FF/70-98% Time delay for max-min voltage or voltage loss, phase loss ❸: 0.0-900.0 seconds. MK 01 R1 Current loss: FF/2-100% Maximum current: FF/102-200% Maximum current instantaneous tripping: FF/110-600% Minimum current: FF/5-98% Time delay for max-min current or current loss ❸: 0.0-900.0 seconds. MK 03 R1 Maximum frequency: FF/101-110% Minimum frequency: FF/90-99% Time delay for min-max frequency ❸: 0.5-900.0 seconds. MK 04 R1 Minimum-maximum cos thresholds in 4 quadrants Minimum-maximum PF thresholds in 4 quadrants elay time for max or min threshold ❸: 1-9,000 seconds. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U 508, CS C22.2 n 14. ❸ Independent adjustable delays. -20 ccessories page -30 imensions page -34 Wiring diagrams page -38 page -46

igital measuring instruments Flush-mount E instruments three phase non expandable MK 1... rder isplayd Relay Qty Wt code measurements output per n n Voltmeter. MK 10 3 phase voltage values 1 0.297 MK 10 R1❷ 3 phase to phase voltage values 1 1 0.330 3 maximum phase voltage values 3 maximum phase to phase voltage values 3 minimum phase voltage values 3 minimum phase to phase voltage values mmeter. MK 11 3 phase current values 1 0.292 MK 11 R1❷ 3 maximum phase current values 1 1 0.336 3 minimum phase current values Combined voltmeter, ammeter and wattmeter. MK 15 3 phase voltage values 1 0.332 MK 15 R1❶❷ 3 phase to phase voltage values 1 1 0.350 3 phase current values 4 active power values, phase and total 3 maximum phase voltage values 3 maximum phase to phase voltage values 3 maximum phase current values 4 maximum active power values, phase and total 3 minimum phase voltage values 3 minimum phase to phase voltage values 3 minimum phase current values 4 minimum active power values, phase and total ❶ Connection also to single phase. ❷ Relay output for control and protection functions. General characteristics The MK 1... instruments are available with flush-mount housing, 96x48mm/3.78x1.9 size. Measurements are TRMS values and provide for reliable operation even in presence of harmonics. perational characteristics uxiliary supply voltage: 220-240VC standard; 24VC, 110-127VC or 380-415VC type on request perating frequency: 50-60Hz TRMS measurements HIGH and W measurement storage 1 relay output with 1 changeover contact (SPT) for MK...R1 only Housing: Flush mount 96x48mm/3.78x1.9 Terminals: 4mm 2 IEC protection degree: IP54 on front; IP20 at terminals. MK 10 - MK 10 R1 Voltage measurement range: 15-660VC perating frequency range: 45-65Hz Programmable VT ratio: 1.00-500.00 ccuracy: ±0.25% f.s. ±1 digit. MK 11 - MK 11 R1 Current measurement range: 0.05-5.75 perating frequency range: 45-65Hz Programmable CT ratio: 5-10,000 ccuracy: ±0.5% f.s. ±1 digit. MK 15 - MK 15 R1 Voltage measurement range: 35-660VC Current measurement range: 0.05-5.75 Frequency measure range: 45-65Hz Programmable VT ratio: 1.00-500.00 Programmable CT ratio: 5-10,000 ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit Power ±1% f.s. ±1 digit. Control and protection functions MK 10 R1 Phase loss or failure: FF/5-85% Maximum voltage: FF/102-120% Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Frequency Maximum frequency: FF/101-110% Minimum frequency: FF/90-99% Time delay for max-min voltage, phase loss, asymmetry and min-max frequency ❸: 0.5-900.0 seconds. MK 11 R1 Current loss: FF/2-100% Maximum current: FF/102-200% Maximum current instantaneous tripping: FF/110-600% Minimum current: FF/5-98% symmetry: FF/2-20% Time delay for max-min current or current loss and asymmetry ❸: 0.5-900.0 seconds. MK 15 R1 Voltage Phase loss or failure: FF/5-85% Maximum voltage: FF/102-120% Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Current Current loss: FF/5-85% Maximum current: FF/102-200% Maximum current instantaneous tripping: FF/110-600% Minimum current: FF/5-98% symmetry: FF/2-20% Power Rated power: 1-10,000 Maximum power: FF/101-200% Max. power instantaneous tripping: FF/110-600% Minimum power: FF/10-99% Freuency Maximum frequency: FF/101-110% Minimum frequency FF/90-99% Time delay for max-min voltage, max-min current or current loss, phase loss, asymmetry and min-max power ❸: 0.0-900.0 seconds. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U 508, CS C22.2 n 14. ❸ Independent adjustable delays. ccessories page -30 imensions page -34 Wiring diagrams page -38 page -47-21

igital measuring instruments Flush-mount E multimeter three phase non expandable MK 16 rder isplayed Qty Wt code measurements per MK 16 3 phase voltage values 1 0.350 3 phase to phase voltage values 3 phase current values 4 active power values, phase and total 4 reactive power values, phase and total 4 apparent power values, phase and total 3 phase power factor values 1 frequency value 1 active energy value in kwh 1 reactive energy value in kvarh 1 hour counter 3 maximum phase voltage values 3 maximum phase to phase voltage values 3 maximum phase current values 4 maximum active power values, phase and total 4 maximum reactive power values, phase and total 4 maximum apparent power values, phase and total 3 minimum phase voltage values 3 minimum phase to phase voltage values 3 minimum phase current values 4 minimum active power values, phase and total 4 minimum reactive power values, phase and total 4 minimum apparent power values, phase and total General characteristics The MK 16 multimeter is available with flush-mount housing, 96x48mm/3.78x1.9 size. Measurements are True RMS values and provide for reliable operation even in presence of harmonics. perational characteristics uxiliary supply voltage: 220-240VC standard; 24VC, 110-127VC or 380-415VC type on request perating frequency: 50-60Hz True RMS measurements ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit ctive energy accuracy: Class 2 (IEC/E 62053-21 and IEC/E 62053-) HIGH and W measurement storage Voltage measurement range: 35-660VC Current measurement range: 0.05-5.75 perating frequency range: 45-65Hz Programmable VT ratio: 1.00-500.0 Programmable CT ratio: 5-10,000 Housing: Flush mount 96x48mm/3.78x1.9 Terminals: 4mm 2 IEC protection degree: IP54 on front; IP20 at terminals. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U508, CS C22.2 n 14. -22 ccessories page -30 imensions page -34 Wiring diagrams page -38 page -47

igital measuring instruments Flush-mount E multimeter three phase non expandable MK 16 R1 rder code isplayed Relay Qty Wt measurements output per n n MK 16 R1❶ 3 phase voltage 1 1 0.353 values 3 phase to phase voltage values 3 phase current values 4 active power values, phase and total 4 reactive power values, phase and total 4 apparent power values, phase and total 3 phase power factor values 1 frequency value 1 active energy value in kwh 1 reactive energy value in kvarh 1 hour counter 3 maximum phase voltage values 3 maximum phase to phase voltage values 3 maximum phase current values 4 minimum and maximum active power values, phase and total 4 minimum and maximum reactive power values, phase and total 4 minimum and maximum apparent power values, phase and total 2 minimum and maximum power factor values ❶ Connection also to single phase. General characteristics The MK 16 R1 multimeter is available with flush-mount housing, 96x48mm/3.78x1.9 size. Measurements are True RMS values and provide for reliable operation even in presence of harmonics. perational characteristics uxiliary supply voltage: 220-240VC standard; 24VC, 110-127VC or 380-415VC type on request perating frequency: 50-60Hz True RMS measurements ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit ctive energy accuracy: Class 2 (IEC/E 62053-21 and IEC/E 62053-) HIGH and W measurement storage Voltage measurement range: 35-660VC Current measurement range: 0.05-5.75 Frequency measurement range: 45-65Hz Programmable VT ratio: 1.00-500.0 Programmable CT ratio: 5-10,000 1 relay output with 1 changeover (SPT) contact Housing: Flush mount 96x48mm/3.78x1.9 Terminals: 4mm 2 IEC protection degree: IP54 on front; IP20 at terminals. PRGRMMBE REY UTPUT Voltage Phase loss or failure: FF/5-85% Maximum voltage: FF/102-120% Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Current Protection inhibition max current: FF/2-100% Maximum current: FF/102-200% Maximum current instantaneous tripping: FF/110-600% Minimum current: FF/5-98% symmetry: FF/2-20% Power factor Maximum power factor: 0.10-1.00 Minimum power factor: 0.10-1.00 Time delay for max-min voltage, max-min current or current loss, phase loss, asymmetry and min-max power factor ❷: 0.0-900.0 seconds. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U 508, CS C22.2 n 14. ❷ Independent adjustable delays. ccessories page -30 imensions page -34 Wiring diagrams page -38 page -47 -

igital measuring instruments Flush mount E multimeters non expandable 47 electrical parameters MK 2... rder code escription Qty Wt per MK 20 Basic version, auxiliary 1 0.434 supply 208-240VC MK 21 Version with energy 1 0.477 meters included, auxiliary supply 208-240VC MK 22 Version with energy 1 0.477 meters and RS485 port included, auxiliary supply 208-240VC MK 25 Version for generating 1 0.350 set duty, auxiliary supply 12-24VC General characteristics MK 2... digital multimeters are available with fush-mount housing, 96x96mm/3.78x3.78 size. They monitor and view reliable readings of electrical parameters, even in presence of critical operating conditions, such as voltages and currents with high harmonic content and variable frequency. The total and partial hour counter feature provides an interesting feature for electric panels of emergency generating sets. The diversified and accurate measurements give the multimeters valuable technical and cost effective advantages respect to traditional analog instrumentation. MK2... digital multimeters view 47 electrical parameters: Voltage: phase, line and system values Battery voltage: 9-32VC for MK 25 only Current: phase values Power: apparent phase, active and reactive values P.F.: power factor per phase Frequency (measured voltage frequency) HIGH/W: instantaneous minimum and maximum values of each phase voltage and current, total active power ( W), total reactive power ( var) and total apparent power ( V) values Total hours: non-volatile clearable log for MK 20 and MK 25 only Partial hours: non-volatile configurable log for MK 20 and MK 25 only ctive and reactive energy meters for MK21 and MK22 only. perational characteristics uxiliary supply voltage range: 154-288VC for MK 20 177-264VC for MK 21-MK 22 9-32VC for MK 25 Voltage measurement range: 60-830VC phase-phase 30-480VC phase-neutral Current measurement range: 0.05-6 Frequency measurement range: 45-65Hz Programmable CT ratio: 1.0-2,000 Voltage accuracy: Class 0.5 ±0.35% f.s. (830V) Current accuracy: Class 0.5 ±0.5% f.s. (6) ctive energy accuracy: Class 2 on-volatile total and partial hour counter with separate clearing; used as maintenance interval with alarm display in MK 20 - MK 25 only HIGH and W value functions to read and log instantaneous voltage, current and power values elayed automatic resetting of default measurements veraging function to slow down repetitive fluctuations to obtain more stable readouts Current connection in R configuration by 2 current transformers (CTs) only Single, two, three phase, with or without neutral, and balanced three-phase connection RS485 serial port, compatible with software TRMS measurements up to 22 harmonic order Housing: Flush mount 96x96mm/3.78x3.78 IEC protection degree: IP54 on front; IP 20 at rear. supervision and energy management software See Section 28. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices- Multimeters. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U508, CS C22.2 n 14. -24 ccessories page -30 and 31 imensions page -34 Wiring diagrams page -39 page -48

igital measuring instruments Flush mount E multimeters non expandable 251 electric parameters MK 3... MK 40 rder code escription Qty Wt per MK 30 Basic version, auxiliary supply 1 0.410 100-240VC / 110-250VC MK 31 Version with 1 relay and 1 0.480 1 static programmable outputs, auxiliary supply 100-240VC / 110-250VC MK 32 Version with 1 relay and 1 0.490 1 static programmable outputs and RS485 opto-isolated port, auxiliary supply 100-240VC / 110-250VC MK 32 048 Version with 1 relay and 1 0.485 1 static programmable outputs and RS485 opto-isolated port, auxiliary supply 24-48VC MK 40 Version with data-logger, 1 0.470 RS2 and RS485 opto-isolated ports, auxiliary supply 100-240VC / 110-250VC General characteristics MK3... and MK40 digital multimeters are available with flush-mount housing, 96x96mm/3.78x3.78 size. They comprise excellent features so distorted waveform conditions, such as very disturbed supply lines having voltage and currents with high harmonic content and variable freqeuncy, do not influence the high accuracy of MK multimeter readouts, because of the rigorous deisgn in addition to the use of the latest generation of microprocessor technology. Measurement of the phase angle (cos ) in addition to power factor, harmonic analysis and HIGH-W- MX EM functions are just a few of those which are difficult to find on higher category equipment. The MK 40 version includes a reliable data-logger system, extremely easy to use. MK 3... and MK 40 multimeters can display 251 electric parameters; a few of these are listed below: Voltage: phase, line and system values Current: phase and system values Power: active, reactive, apparent phase and total values Energy: import, export, active and reactive values P.F.: power factor per phase cos : angle displacement, i.e. power factor related to the harmonic fundamental only Frequency of measured voltage value Harmonics (HRM.): residual and total harmonic content for each harmonic order up to the 22 per phase, both for voltage and current values HIGH / W: maximum / minimum values of phase voltage and current and W, var and V power Maximum demand (MX): maximum current and total active power values, both calculated on programmable integration time. The technical features of the MK 40 data-logger are: 2Mbyte (MB) non-volatile memory for data logging Real Time Clock (RTC) with replaceable backup lithium battery Sampling time, 1s to 24h configurable umber of sampling measurements, 1 to 32 configurable at a time Communication protocols: Modbus-RTU and Modbus-SCII ata logging of one electrical parameter in continuous format or with begin-end by programmable thresholds Compatible with software Suspension of data acquisition at full memory or refreshing oldest data. perational characteristics perating auxiliary voltage range: 85-265VC / 93.5-300VC; 18-70VC for MK32 048 Voltage measurement range: 20-830VC phase-phase; 10-480VC phase-neutral VT ratio programming: 1.0-5,000 Current measurement range: 0.02-6 Frequency measurement range: 45-65Hz CT ratio programming: 1.0-2,000 Voltage accuracy: ±0.25% f.s. (830V) Current accuracy: ±0.35% f.s. (6) Frequency and harmonic distortion accuracy: ±1 digit ctive energy accuracy: Class 1 HIGH and W value functions to detect and log instantaneous voltage, current and power values veraging function to slow down repetitive fluctuations to obtain more stable readouts Current connection in R configuration by 2 current transformers only Single, two, three phase, with or without neutral, and balanced three-phase connection by 1 CT only Usage with voltage transformers for voltages >830VC perating frequency range: 45-65Hz True RMS measurements up to 22 harmonic order Power factor and cos measurements Voltage and current harmonic analysis per phase up to 22 harmonic order ctive energy meters (import-export) Reactive energy meters (import-export) Housing: Flush mount 96x96mm/3.78x3.78 IEC protection degree: IP54 on front; IP 20 at rear. supervision and energy management software See Section 28. Certifications and compliance Certifications obtained: EC; U isted, for US and Canada (cuus - File E93601), as uxiliary evices - Multimeters. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, CISPR11/E 55011, U508, CS C22.2 n 14. ccessories page -30 and 31 imensions page -34 Wiring diagrams page -39 page -48-25

igital measuring instruments Modular E instruments single phase non expandable MK 80 MK 81 MK 80 R1 MK 81 R1 MK 82 MK 82 rder isplayed Relay Qty Wt code measurements output per n n Voltmeter. MK 80 1 voltage value 1 0.7 MK 80 R1❷ 1 max voltage value 1 min voltage value 1 1 0.268 mmeter. MK 81 1 current value 1 0.7 MK 81 R1❷ 1 max current value 1 min current value 1 1 0.268 Voltmeter or ammeter. MK 82❶ 1 voltage or current 1 0.241 value 1 maximum voltage or current value 1 minimum voltage or current value Frequency meter. MK 83 1 frequency value 1 0.7 MK 83 R1❷ 1 max frequency value 1 1 min frequency value 1 0.268 Cosphi meter. MK 84 1 cosphi value 1 0.241 MK 84 R1❷ 1 power factor value 1 1 0.272 ❶ The MK82 can operate as a voltmeter or ammeter. It is duly equipped with two front plates (V and ) which must be fitted by the user depending on which instrument is required and on the wiring scheme used. ❷ Relay output with control and protection functions. General characteristics The MK 8... instruments are available with modular housing, 3 module size. Measurements are True RMS values and provide for reliable operation even in presence of harmonics. perational characteristics uxiliary supply voltage: 220-240VC standard; 24VC, 110-127VC or 380-415VC type on request perating frequency: 50-60Hz True RMS measurements HIGH and W measurement storage 1 relay output with 1 changeover contact (SPT) for MK...R1 version only Terminals: 4mm 2 Modular I 43880 housing, 3 modules IEC degree of protection: IP40 on front; IP20 on terminals. MK 80 - MK 80 R1 Voltage measurement range: 15-660VC perating frequency range: 45-65Hz Programmable VT ratio: 1.00-500.00 ccuracy: ±0.25% f.s. ±1 digit MK 81 - MK 81 R1 Current measurement range: 0.05-5.75 perating frequency range: 45-65Hz Programmable CT ratio: 5-10,000 ccuracy: ±0.5% f.s. ±1 digit MK 82 Voltage measurement range: 15-660VC Current measurement range: 0.05-5.75 perating frequency range: 45-65Hz Programmable VT ratio: 1.00-500.00 Programmable CT ratio: FF/5-10,000 ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit MK 83 - MK 83 R1 Measurement input: 15-660VC Frequency measurement range: 50-60Hz ±10% Measurement accuracy: ±1 digit ccuracy: ±1 digit MK 84 - MK 84 R1 Cosphi measurement error: ±0.5 ±1 digit Cosphi measurement in 4 quadrants ccuracy: ±1 ±1 digit MK 83 MK 83 R1 Control and protection functions MK 80 R1 Voltage loss or failure: FF/5-85% Maximum voltage: FF/102-120% Minimum voltage: FF/70-98% Time delay for max-min voltage or voltage loss, phase loss ❸: 0.0-900.0 seconds. MK 81 R1 Current loss: FF/2-100% Maximum current: FF/102-200% Maximum current instantaneous tripping: FF/110-600% Minimum current: FF/5-98% Time delay for max-min current or current loss ❸: 0.0-900.0 seconds. MK 84 MK 84 R1 MK 83 R1 Maximum frequency: FF/101-110% Minimum frequency: FF/90-99% Time delay for min-max frequency ❸: 0.5-900.0 seconds. MK 84 R1 Minimum-maximum cos thresholds in 4 quadrants Minimum-maximum PF thresholds in 4 quadrants elay time for max or min threshold ❸: 1-9,000 seconds. Certifications and compliance Certifications obtained: EC. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3. ❸ Independent adjustable delays. -26 imensions page -35 Wiring diagrams page -38 page -46

igital measuring instruments Modular E instruments three phase non expandable MK 70 MK 71 MK 75 MK 70 R1 MK 71 R1 MK 75 R1 rder isplayed Relay Qty Wt code measurements output per n n Voltmeter. MK 70 3 phase voltage values 1 0.3 MK 70 R1❷ 3 phase to phase voltage values 1 1 0.264 3 max phase voltage values 3 max phase to phase voltage values 3 min phase voltage values 3 min phase to phase voltage values mmeter. MK 71 3 phase current values 1 0.241 MK 71 R1❷ 3 max phase current values 1 1 0.272 3 min phase current values Combined voltmeter, ammeter and wattmeter. MK 75 3 phase voltage values 1 0.271 MK 75 R1❶❷ 3 phase to phase voltage values 1 1 0.280 3 phase current values 4 active power values, phase and total 3 maximum phase voltage values 3 maximum phase to phase voltage values 3 maximum phase current values 4 max active power, phase and total 3 minimum phase voltage values 3 minimum phase to phase voltage values 3 minimum phase current values 4 min active power, phase and total ❶ Connection also to single phase. ❷ Relay output with control and protection functions. General characteristics The MK 7... instruments are available with modular housing, 3 module size. Measurements are True RMS values and provide for reliable operation even in presence of harmonics. perational characteristics uxiliary supply voltage: 220-240VC standard; 24VC, 110-127VC or 380-415VC type on request perating frequency: 50-60Hz True RMS measurements HIGH and W measurement storage 1 relay output with 1 changeover contact (SPT) for MK...R1 version only Terminals: 4mm 2 Modular I 43880 housing, 3 module IEC degree of protection: IP40 on front; IP20 on terminals. MK 70 - MK 70 R1 Voltage measurement range: 15-660VC perating frequency range: 45-65Hz Programmable VT ratio: 1.00-500.00 ccuracy: ±0.25% f.s. ±1 digit MK 71 - MK 71 R1 Current measurement range: 0.05-5.75 perating frequency range: 45-65Hz Programmable CT ratio: 5-10,000 ccuracy: ±0.5% f.s. ±1 digit MK 75 - MK 75 R1 Voltage measurement range: 35-660VC Current measurement range: 0.05-5.75 Frequency measure range: 45-65Hz Programmable VT ratio: 1.00-500.00 Programmable CT ratio: 5-10,000 ccuracy: Voltage ±0.25% f.s. ±1 digit Current ±0.5% f.s. ±1 digit Control and protection functions MK 70 R1 Phase loss or failure: FF/5-85% Maximum voltage: FF/102-120% Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Maximum frequency: FF/101-110% Minimum frequency: FF/90-99% Time delay for max-min voltage, phase loss, asymmetry and min-max frequency ❸: 0.0-900.0 seconds. MK 71 R1 Current loss: FF/2-100% Maximum current: FF/102-200% Maximum current instantaneous tripping: FF/110-600% Minimum current: FF/5-98% symmetry: FF/2-20% Time delay for max-min current or current loss and asymmetry ❸: 0.0-900.0 seconds. MK 75 R1 Voltage Phase loss or failure: FF/5-85% Maximum voltage: FF/102-120% Minimum voltage: FF/70-98% symmetry: FF/2-20% Phase sequence: FF/1-2-3/3-2-1 Current Current loss: FF/2-100% Maximum current: FF/102-200% Maximum current instantaneous tripping: FF/110-600% Minimum current: FF/5-98% symmetry: FF/2-20% Power Rated power: 1-10,000 Maximum power: FF/101-200% Maximum power instantaneous tripping: FF/110-600% Minimum power: FF/10-99% Frequency Maximum frequency: FF/101-110% Minimum frequency: FF/90-99% Time delay for max-min voltage, max-min current or current loss, phase loss, asymmetry and min-max power ❸: 0.0-900.0 seconds. Certifications and compliance Certifications obtained: EC. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3. ❸ Independent adjustable delays. imensions page -35 Wiring diagrams page -38 page -47-27

igital measuring instruments. Starter kits Modular E multimeters non expandable 47 electric parameters MK 5... MKKIT 51 060 MKKIT 51 080 MKKIT 51 100 MKKIT 51 150 MKKIT 51 200 MKKIT 51 250 rder escription Qty Wt code per MK 50 Basic version, 1 0.398 auxiliary supply 208-240VC MK 51 Version with energy 1 0.420 meters included, auxiliary supply 208-240VC MK 52 Version with energy meters 1 0.420 and RS485 port, auxiliary supply 208-240VC Starter kits rder escription Qty Wt code per MKKIT 51 060 Kit composed of one 1 1.020 MK 51 multimeter and three 60/5 CTs for Ø22mm/0.87 cable MKKIT 51 080 Kit composed of one 1 1.020 MK 51 multimeter and three 80/5 CTs for Ø22mm/0.87 cable MKKIT 51 100 Kit composed of one 1 1.020 MK 51 multimeter and three 100/5 CTs for Ø22mm/0.87 cable MKKIT 51 150 Kit composed of one 1 0.810 MK 51 multimeter and three 150/5 CTs for Ømm/0.91 cable MKKIT 51 200 Kit composed of one 1 0.810 MK 51 multimeter and three 200/5 CTs for Ømm/0.91 cable MKKIT 51 250 Kit composed of one 1 8.210 MK 51 multimeter and three 250/5 CTs for Ømm/0.91 cable General characteristics MK 5... digital multimeters are available with modular housing, 6 module size. They monitor and view reliable readings of electric parameters, even in presence of critical operating conditions, such as voltages and currents with high harmonic content and variable frequency. The total and partial hour counter feature provides an interesting feature for electric panels of emergency generating sets. The diversified and accurate measurements give the multimeters valuable technical and cost effective advantages respect to traditional analog instrumentation. The digital multimeters MK 5... view 47 electric parameters: Voltage: phase, line and system values Current: phase values Power: apparent phase, active and reactive values P.F.: power factor per phase Frequency of measured voltage value HIGH/W: instantaneous minimum and maximum values of each phase voltage and current, total active power ( W), total reactive power ( var) and total apparent power ( V) values Total hours: non-volatile clearable log for MK 50 only Partial hours: non-volatile configurable log for MK 50 only ctive and reactive energy meters for MK 51 and MK 52 only. perational characteristics MK 50 - MK 51 - MK 52 uxiliary supply voltage range: 154-288VC for MK 50 177-264VC for MK 51-MK 52 Voltage measurement range: 60-830VC phase-phase; 30-480VC phase-neutral Current measurement range: 0.05-6 Frequency measurement range: 45-65Hz Programmable CT ratio: 1.0-2,000 ccuracy: Voltage-class 0.5 ±0.35% f.s. (830V) Current-class 0.5% ±0.5% f.s. (6) ctive energy accuracy: Class 2 on-volatile total and partial hour counter with separate clearing; used as maintenance interval with alarm display in MK 50 only HIGH and W value functions to read and log instantaneous voltage, current and power values elayed automatic resetting of default measurements veraging function to slow down repetitive fluctuations to obtain more stable readouts Current connection in R configuration by 2 current transformers (CTs) only Single, two, three phase with or without neutral True RMS measurements up to 22 harmonic order RS485 serial port, software compatible for MK 52 Modular I 43880 housing, 6 module IEC degree of protection: IP41 on front; IP 20 on terminals. CURRET TRSFRMERS (CTs) of starter kits perating frequency: 50-60Hz Secondary output current: 5 Class 1 burden verload withstand: 120% Ipn Rated insulation voltage Ui: 720V Rated short time thermal current Ith: 40-60Ipn for 1 second Rated dynamic current Idyn: 2.5Ith for 1 second Insulation (dry type): class E Faston terminals Standard supplied fixing elements IEC degree of protection: IP30. supervision and energy management software See Section 27. Certifications and compliance Certifications obtained: EC for MK 5...; U isted, for US and Canada (cuus - File E93601), as uxiliary evices - Multimeters for MK5... types, in the starter kits as well. Compliant with standards, IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U508, CS C22.2 n 14 for MK5 ; IEC/E 60044-1 for transformers of starter kits. -28 Software and accessories page -30 imensions page -35 Wiring diagrams page -39 page -49

igital measuring instruments Modular E multimeters non expandable 251 electric parameters MK 6... rder escription Qty Wt code per MK 60 Basic version, 1 0.290 auxiliary supply 100-240VC/110-250VC MK 61 Version with 1 relay and 1 0.300 1 static programmable outputs, auxiliary supply 100-240VC / 110-250VC MK 62 Version with 1 relay and 1 0.320 1 static programmable outputs, and RS485 port, auxiliary supply 100-240VC / 110-250VC General characteristics MK6... digital multimeters are avaibalble with modular housing, 6 module size. They comprise excellent features, superior to devices of the same category currently on the marketplace. istorted waveform conditions, such as very disturbed electric lines having voltage and currents with high harmonic content and variable frequency, do not influence the high accuracy MK multimeter readouts because of rigorous design in addition to the use of the latest generation of microprocessor technology. Measurement of the phase angle (cos ) in addition to power factor, harmonics analysis and HIGH-W-MX functions are just a few of those which are difficult to find on higher category equipment. MK 6... digital multimeter can display 251 electric parameters; a few of these are listed below. Voltage: phase, line and system values Current: phase and system values Power: active, reactive, apparent phase and total values Energy: active, reactive import and export values P.F.: power factor per phase cos : angle displacement, i.e. power factor related to the harmonic fundamental only Frequency of measured voltage value Harmonics (HRM.): residual and total harmonic content for each harmonic order up to the 22 per phase, both for voltage and current values HIGH / W: maximum / minimum values of phase voltage and current and W, var and V power Maximum (MX): maximum current and total active power values, both calculated on programmable integration time. perational characteristics uxiliary supply voltage range: 85-265VC/93.5-300VC Voltage measurement range: 20-830VC phase-phase 10-480VC phase-neutral VT ratio programming: 1.0-5,000 Current measurement range: 0.02-6 Frequency measurement range: 45-65Hz CT ratio programming: 1.0-2000 ccuracy: Voltage ±0.25% f.s. (830V) Current ±0.35% f.s. (6) Frequency and harmonic distortion ±1 digit ctive energy accuracy: Class 1 HIGH and W value functions to detect and log instantaneous voltage, current and power values veraging function to slow down repetitive fluctuations to obtain more stable readouts Current connection in R configuration via 2 current transformers only Single, two, three phase with or without neutral and balanced three-phase connection via 1 current transformer only Usage with voltage transformers for voltages >830VC True RMS measurements up to 22 harmonic order, class 1 accuracy Power factor and cos measurement Voltage and current harmonic analysis per phase up to 22 harmonic order ctive energy meters (import-export) Reactive energy meters (import-export) RS485 serial port, compatible with software for MK 62 Modular I 43880 housing, 6 module IEC degree of protection: IP41 on front; IP 20 on terminals. supervision and energy management software See Section 27. Certifications and compliance Certifications obtained: EC; U isted for US and Canada (cuus - File E93601) as uxiliary evices - Multimeters. Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, CISPR11/E55011, U508, CS C22.2 n 14. Software and accessories page -30 imensions page -35 Wiring diagrams page -39 page -49-29

Communication devices, coves and accessories for measuring instruments Communication devices rder code escription Qty Wt per CX 01 CX 02 CX 03 CX 01 USB/optical dongle with 1 0.090 PC VT Electric product connecting cable, for programming, data download, diagnostics and firmware upgrade CX 02 Wi-Fi dongle for PC VT 1 0.090 Electric product programming, data download, diagnostics and cloning CX 03 GSM/GPRS quad-band antenna 1 0.090 (800/900/1800/199Mhz) for EXP1015 expansion module General characteristics Communication devices for connection of VT Electric products to personal computers, smartphones and tablets. CX 01 The USB/optical dongle, complete with cable, allows the connection of products compatible with PCs without having to disconnect the power supply from the electric panel. The PC identifies the connection as a standard USB. CX 02 By Wi-Fi connection, compatible VT Electric products can be viewed on PCs, smartphones and tablets with no need for cabling. CX 03 ntenna compatible with the major part of worldwide mobile networks thanks to the available frequencies at 800/900/1800/1900MHz. IEC degree of protection: IP67. Fixing by Ø12mm/0.04 drilling. For dimensions, wiring schemes and technical characteristics, refer to technical instructions in ownloads of local or global websites or consult Customer Service. See contact details on the inside front cover. Protection covers rder code escription Qty Wt per P 96X48 Front protection cover, IEC IP65 1 0.048 for MK 0 and MK 1 31 P 96X96 Front protection cover, IEC IP54 1 0.077 for MK 2, MK 3 and MK 40 General characteristics When a higher front IP protection degree is needed, the covers can be installed on the corresponding devices and also provide a sealing feature. ccessories rder code escription Qty Wt per EXP80 00 Plastic insert for customising 10 0.005 label fixing for MG 600/610 EXP80 00 EXM80 04 Set of sealable terminal covers 1 0.020 for MG 200/210/300-30

Converter drive, cables, clamp kits and software for measuring instruments RS2-RS485 converter drive 4 PX1 51 C4 rder code escription Qty Wt per 4 PX1 RS22/RS485 converter 1 0.600 drive, opto-isolated, 220-240VC ❶ ❶ RS2/RS485 opto-isolated converter drive, 38,400 Baud rate maximum, automatic or manual TRSMIT line supervision, 220-240VC ±10% (110-120VC supply on request). Connecting cables rder code escription Qty Wt per MG M3 KIT... Connecting cables. 51 C2 For PC multimeter RS2 1 0.090 port, 1.8m/2yd long 51 C4 For PC 4 PX1 converter drive, 1 0.147 1.8m/2yd long 51 C5 For analog modem multimeter 1 0.111 RS2 port, 1.8m/2yd long 51 C9 For 4PX 1 converter 1 0.137 drive analog modem, 1.8m/2yd long Current clamp kits for MG M3. portable devices. MG M3 KIT01 Composed by 3 current 1 6.900 clamps 1000/1 and 4 alligator clip cables for voltage measurements MG M3 KIT02 Composed by 1 current 1 0.860 clamps 1000/1 and 1 alligator clip cable for voltage measurements. For MGM3900, if measuring inputs for neutral-earth/ground and neutral current are used too Software rder code escription Qty Wt per Software. MK SW Remote control software for 1 0.246 PC-MK 22/32/40/52/62 and PC-MG 210/200/600/800/900 having Modbus-RTU and SCII protocols, complete with 51 C4 connecting cable MK SW10 MK SW 10 ata-logger software complete 1 0.400 with 31 C2 connecting cable. Remote control and supervision Software for PC-MK / MG (as above) having Modbus-RTU and SCII protocols, complete with 51 C4 connecting cable General characteristics RS2-RS485 CVERTER RIVE It can interface slave devices connected in an RS485 bus with a master equipped with RS2 interface port. When configured appropriately, it can also be used as RS485 repeater whenever the devices connected to the bus are many or the maximum distance among the bus devices is longer than the allowed. CECTIG CBES 51 C To connect energy meters and/or multimeters with: Personal computers Modems Bus converters. Electrical safety for MG M3 (IEC/E 61010-1 and IEC/E 61010-2-032) CURRET CMPS 600V category III (industrial and services) with antislip protection and conductor anti-pinching system 300V category IV. VTGE MESURIG CBES 1000V category III (industrial and services). MK SW SFTWRE Remote control software for MK 22, MK 32, MK 40, MK 52, MK 62, MG 210, MG 300, MG 700, MG 800, MG 900 and MG 900T. This software is capable of controlling a maximum of 250 digital multimeters remotely connected to one RS485 bus. The MK SW is subdivided into modules which warrant simple and easy use: Main synoptic page which includes the most important in-coming data of the various MK/MG connected etailed page with data related to the selected MK/MG unit ata log which consents to store sampled measurements on disk (max 128 measurements) Events / alarms log with alarm data acquisition of the various MKs/MGs as well as the elaborated analysis Trend graphs to control electric parameters status Harmonic content analysis bar graph Energy count to periodically view energy counters of the various instruments and monitor energy consumption. MK SW10 SFTWRE ata-logger and remote control for MK 40 and MG... with memory modules. The MK SW10 includes the data-logger software and the remote control MK SW software, two applications with separate installation. The data-logger software permits: To configure multimeter parameters for data logging and installation parameters (VT and CT ratio, etc.) To view and print acquired data from the multimeter storage memory in table or trend graph format. o data-logger configuration or stored data viewing is obtainable on the unit front To download data in CCESS, EXCE or TEXT file To view all actual electric parameter measurements on a virtual multimeter display (MK only) To program the multimeter clock-calendar (RTC - Real Time Clock) to automatically manage daylight saving time To connect directly or via modem with the multimeters. supervision and energy management software See Section 27. Reference standards Compliant with standards: IEC/E 61010-1, IEC/E 61000-6-2, IEC/E 61000-6-3, U508, CS C22.2 n 14. For dimensions, wiring schemes and technical characteristics, refer to technical instructions in ownloads of local or global websites or consult Customer Service. See contact details on the inside front cover. -31

Current transformers Solid-core M0T... M2T... M3T... M4T... rder code Primary Burden Qty Weight current Class Class per Ipn 0.5 1 /5 [] [V] [V] For Ø22mm/0.9 cable. M0T 0050 50 1.25 1 0.200 M0T 0060 60 1.5 1 0.200 M0T 0080 80 1.5 1 0.200 M0T 0100 100 1.5 1 0.200 M0T 0150 150 1 0.200 For Ømm/0.9 cable. For 30x10mm/1.2x0.4, 25x12.5mm/1x0.5, 20x15mm/0.8x0.4 busbars. M2T 0100 100 1.5 1 0.130 M2T 0150 150 1.5 1 0.130 M2T 0200 200 2.5 1 0.130 M2T 0250 250 2.5 1 0.130 M2T 0300 300 1.5 3 1 0.130 M2T 0400 400 2 3 1 0.130 For Ø30mm/1.2 cable. For 40x10mm/1.6x0.4, 30x20mm/1.2x0.8, 25x25mm/1x1 busbars. M3T 0200 200 5 1 0.260 M3T 0250 250 5 1 0.260 M3T 0300 300 2.5 5 1 0.260 M3T 0400 400 2.5 5 1 0.260 M3T 0500 500 2.5 5 1 0.260 M3T 0600 600 5 10 1 0.260 M3T 0800 800 5 10 1 0.260 M3T 1000 1000 5 10 1 0.260 For Ø86mm/3.4 cable. For 100x30mm/3.9x1.2, 80x50mm/3.1x2, 70x60mm/2.8x2.4 busbars. M4T 1000 1000 10 20 1 0,700 M4T 1200 1200 15 30 1 0.700 M4T 1250 1250 15 30 1 0.760 M4T 1500 1500 30 30 1 0.760 M4T 1600 1600 30 30 1 0.800 M4T 2000 2000 45 45 1 0.840 M4T 2500 2500 45 45 1 0.900 M4T 3000 3000 45 45 1 0.900 M4T 3500 3500 50 50 1 0.900 M4T 4000 4000 50 50 1 0.900 General characteristics The M... series current transformers (CTs) are installed in electric installations to reduce the line current to a secondary value of 5, which is compatible with current inputs of digital multimeters or protection relays. These are without primary winding and are used for high primary current values from 50 upward. The number of loops of the primary cable does not modify the accuracy but converts the primary current value proportional to secondary current. 300/5 300/5 300/5 S1 K S1 K S1 K J-29 P1-K J-29 P1-K J-29 P1-K S2 300:n/5 300:1/5=300/5 S2 300:n/5 300:2/5=150/5 S2 300:n/5 300:3/5=100/5 n =1 300 / 5 1 loop = 300 / 5 n =2 300 / 5 2 loops = 150 / 5 n =3 300 / 5 3 loops = 100 / 5 M5T... Versions with Italian UTF certificates on request. rder code Primary Burden Qty Weight current Class Class per Ipn 0.5S 0.5 /5 [] [V] [V] For Ø28mm/1.1 cable. For 20x10mm/0.8x0.4 and 30x10mm/1.2x0.4 busbars. M5T 0060❶ 60 1.5 1.5 1 0.560 M5T 0080❶ 80 2.5 2.5 1 0.580 M5T 0100❶ 100 2.5 3.75 1 0.480 M5T 0150❶ 150 2.5 3.75 1 0.480 M5T 0200❶ 200 2.5 3.75 1 0.460 M5T 0250❶ 250 2.5 5 1 0.480 M5T 0300❶ 300 2.5 5 1 0.480 ❶ Consult Customer Service to query about versions with Italian UTF certificates; see contact details on inside front cover. perational characteristics perating frequency: 50-60Hz Secondary output current: 5 verload withstand: 120% Ipn IEC rated insulation voltage Ui: 720V IEC rated short-time thermal current Ith: 40-60 Ipn for 1 second IEC rated dynamic current Idyn: 2.5 Ith for 1 second Insulation (dry type): Class E Terminals: Faston for M2T and M3T types Screw for M0T, M4T and M5T types Sealable terminal covers for M0T, M4T and M5T types Fixing on 35mm I rail (IEC/E 60715) or by screws (fixing elements standard supplied with the product) IEC degree of protection: IP30 mbient conditions perating temperature: -25... +50 C Storage temperature: -40... +80 C. Relative humidity, non condensing: 90%. Reference standards Compliant with standards: IEC/E 60044-1. The UTF certificate is required for revenue tax purposes by Italian authorities when equipment is part of generating electricity installations (e.g. solar, wind) and there is electricity exchange with the power grid. -32 imensions page -35

Current transformers Split-core M1T... M2T... M3T... rder code Primary Burden Qty Weight current Class Class per Ipn 0.5 1 /5 [] [V] [V] For 50x60mm/2x2.4 busbar. M1T 0250 250 1 2 1 0.900 M1T 0300 300 1.5 3 1 0.900 M1T 0400 400 1.5 3 1 0.900 M1T 0500 500 2.5 5 1 0.900 M1T 0600 600 2.5 5 1 0.900 M1T 0750 750 3 6 1 0.900 M1T 0800 800 3 7.5 1 0.900 M1T 1000 1000 5 10 1 0.900 For 80x80mm/3.1x3.1 busbar. M2T 0250 250 1 2 1 1.050 M2T 0300 300 1.5 3 1 1.050 M2T 0400 400 1.5 3 1 1.050 M2T 0500 500 2.5 5 1 1.050 M2T 0600 600 2.5 5 1 1.050 M2T 0750 750 3 6 1 1.050 M2T 0800 800 3 7.5 1 1.050 M2T 1000 1000 5 10 1 1.050 For 80x120mm/3.1x4.7 busbar. M3T 0500 500 4 1 1.250 M3T 0600 600 5 1 1.250 M3T 0750 750 2.5 6 1 1.250 M3T 0800 800 3 7.5 1 1.250 M3T 1000 1000 5 10 1 1.250 M3T 1200 1200 6 12.5 1 1.250 M3T 1250 1250 7.5 15 1 1.250 M3T 1500 1500 8 17 1 1.250 For 80x160mm/3.1x6.3 busbar. M4T 2000 2000 15 20 1 3.160 M4T 2500 2500 15 20 1 3.340 M4T 3000 3000 20 25 1 3.500 M4T 4000 4000 20 25 1 3.760 General characteristics The M... series current transformers (CTs) are installed in electric installations to reduce the line current to a secondary value of 5, which is compatible with current inputs of digital multimeters or protection relays. These are without primary winding and are used for high primary current values from 250 upward. perational characteristics perating frequency: 50-60Hz Secondary output current: 5 verload withstand: 120% Ipn IEC rated insulation voltage Ui: 720V IEC rated short-time thermal current Ith: 40-60 Ipn for 1 second IEC rated dynamic current Idyn: 2.5 Ith for 1 second Insulation (dry type): Class E Screw terminals Sealable terminal covers Screw fixing (fixing elements standard supplied with the product) IEC degree of protection: IP30 mbient conditions perating temperature: -25... +50 C Storage temperature: -40... +80 C. Relative humidity, non condensing: 90%. Reference standards Compliant with standards: IEC/E 60044-1. M4T... imensions page -35-33