Efficient. Innovative. Sustainable.

Similar documents
FCU-MULTI Modbus Fan Coil Unit Controller

AIAS. Technical description

The Simply Smart Way to Optimize Building Control and Performance

SUPERVISION AND CONTROL FOR HYDRONIC TERMINAL UNITS

INTELLIGENT SOLUTION MANAGING AUTOMATION

Climatix Sales Presentation. Kurt Steiner / xxx-x-xxx

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

Web server. Simplified.

FCU-4 FAN COIL CONTROLLER

MOD-RI Room Interface Modules with Modbus

A NEW DATA LOGGER Stand alone. Secure. Fast.

FCU-4 FAN COIL CONTROLLER

LDALI ME204-U, LDALI ME201 U

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

COMTRAXX COM460IP. BMS-Ethernet-Gateway

1.5 PCD1 modular, expandable, compact CPU

Web server. Simplified.

Supervisory Controllers

Controllers / Automation Stations U-DDC

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

Smart Building Automation System Solutions

EXOcompact. Freely programmable controller

Energy & Power Quality Powermeter

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

Satchwell MicroNet. Building Management System MicroNet 50 Series

Communicative controller for VAV systems

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

Free Programmable Control Units

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

EXOcompact. Third generation freely programmable controllers

Efficient and Reliable

BACnet Product Overview

TECHNICAL DATASHEET GENERAL OVERVIEW HARDWARE SPECIFICATIONS KNX SERVER - PAGE 1 RELEASE DATE: 06, REV. NR. 005

BACnet Controller for General-purpose Building Applications

Micro-Modular Programmable Controller

BMS-Ethernet-Gateway COM460IP

Andover ContinuumTM. b3850 Series Terminal Controllers

USER S MANUAL. DAS-G01 The Power of Tomorrow

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

FX Input/Output (I/O) Modules XM07 and XM14

Hotel Room Controller

BMS Steam Station Solutions

Field selectable application type and room module series, via dip-switches on controller

AUTARKIC PROCESS MANAGEMENT

WISE-52xx Intelligent IIoT Concentrator

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

LDALI ME204-U, LDALI ME201 U

Industrial Control SE-607

Web-enabled DAQ System

Priva Blue ID system overview

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

Control systems. Efficient room control

MIO12 Intelligent Modbus Input/Output Modules

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

EC-BOS-8 Multi-protocol Web Building Controller

SAUTER EY-modulo. Compatibility for a secure investment.

CCM-204 MULTI-PURPOSE TEMPERATURE CONTROLLER

supernode Electronic controller for humidification Technical Leaflet Integrated Control Solutions & Energy Savings

RGX COMMUNICATIONS GATEWAY

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

BACnet. b3810 Series Local Controllers

BAS Web Server Datasheet

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

LLR-MOD Modbus Light Level and Occupancy Sensor

our experience...your solution Controlling and Monitoring Gateway

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

EC-BOS-8 Multi-protocol Web Building Controller

MX 62. Monitoring system for gas and flame detection. Certifications. Back up processor to ensure continual measurement (SIL 3 from EN 50402)

LIOB 550/551/552/553/554 V2

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

Measure & Control Temperature & CO2 levels with analog & digital I/O

for M-Bus, Modbus and 1-Wire devices

FX06 Field Controller

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

Intranet Internet VPN. FUSE 6A EXT FUSE 6A status LOYTEC status LIOB-100 L-IOB. 6A status LIOB-100 Automation Server. status LOYTEC L-INX

Andover ContinuumTM Infinet II

Pre-programmed room controller with display and communication

Priva Blue ID C-Line system overview

Communicative heating controller, Ethernet

All it takes to measure, collect and analyze energy consumption in heating and cooling applications

Saia PCD1.Room is for applications in the field of room automation and HeaVAC. PCD1.M2110R1 with Ethernet TCP/IP for room automation applications

Tablet Recorder. Web-enabled DAQ System. Bring your own tablet. Tablet Recorder. Taking signals from PLC and other devices

STRA-17 Room controller. Installation and maintenance manual. Content

Dupline Fieldbus Components

MODULAR CIRCUIT MONITORING SYSTEM

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

PR Series Paperless Recorders

ProfiMessage. NEW Modular. Secure. Adaptable.

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

The new Expert Logger 400: Industry 4.0 ready!

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Innovative hardware...

YZP : SAUTER Vision Center

Transcription:

Efficient. Innovative. Sustainable. Controlesta RCO System Description On-line, at each time, at each place 1

CONTROLESTA RCO System Description 1. System architecture 2.1 Master Controller 2.2 Network Controller 2.3 Compact-Controller 2.4 Expander I/O Module 2.5 I/O-Modules 2.6 Power modules 2.7 Mounting variants 2.8 Operator panel RCO 640D-S 2.9 Operator panel RCO621D-S 2.10 Operator panel RCO 630D-S 2.11 Integrated graphical Display RCO 72.D-... 2.12 Embedded Web server 2.13 Trend-log functionality 2.14 Single Room Controller 3. Building Management Software RCO-view 3.1 Animated visualisations for graphical operations 3.2 Alarm Management 3.3 Access management for user and user groups 3.4 Time Schedule management 3.5 Event monitoring with Log-Files 3.6 Integration of IP cameras 3.7 Historical data, Online Trending 3.8 Intuitive engineering 4. Efficient Engineering RCO-tool 4.1 Configuration 4.2 Programming 4.3 Commissioning 4.4 Documentation 2

1. System architecture Controlesta RCO Ethernet / BACnet RCO 700... I/O Modules Text display Single room controller Master Controller with integrated Display Modbus RS485 1... 32 RCO 72... RCO 5 I/O Modules Modbus RS485 1... 32 RCO 514D-E Network Controller with Text display Network Controller with LCD graphical display Wireless Interfaces Ethernet RS232 RS485 L-Bus Protocols BACnet- /Ethernet BACnet/-P BACnet-MS/TP BACnet-PTP Modbus RTU Master Modbus RTU Slave M-Bus Wilo Grundfos ASCII RCO C TCP/IP Router Wi-Fi System Operation Room automation Integration 3

2.1 Master Controller RCO 700D-M RCO 700D-W Coloured graphical Display 320x240 - - Program and data memory SD-Card 2GB SD-Card 2GB Ports 2x RS232 2x RS232 2x RS485 2x Ethernet 2x RS485 2x Ethernet L-Bus-1 (Connection) RCO C-Modules RCO C-Modules L-Bus-2 (Connection) RCO D-Modules RCO D-Modules Protocols RCO-C bus RCO-C bus BACnet-Ethernet, -IP, -MS/TP, -PTP MODBUS Master/Slave M-Bus Wilo / Grundfos TCP/IP for RCO-view/-tool BACnet-Ethernet, -IP, -MS/TP, -PTP MODBUS Master/Slave M-Bus Wilo / Grundfos TCP/IP for RCO-view/-tool Trend-log Display/Browser RCO 621D-S/- X/X E-mailing X X Web server - X Mounting DIN-rail DIN-rail 4

2.1 Master Controller RCO 720D-M RCO 720D-W Coloured graphical Display 320x240 X X Program and data memory SD-Card 2GB SD-Card 2GB Ports 2x RS232 2x RS232 2x RS485 2x Ethernet 2x RS485 2x Ethernet L-Bus-1 (Connection) RCO C-Modules RCO C-Modules L-Bus-2 (Connection) RCO D-Modules RCO D-Modules Protocols RCO-C bus RCO-C bus BACnet-Ethernet, -IP, -MS/TP, -PTP MODBUS Master/Slave M-Bus Wilo / Grundfos TCP/IP for RCO-view/-tool BACnet-Ethernet, -IP, -MS/TP, -PTP MODBUS Master/Slave M-Bus Wilo / Grundfos TCP/IP for RCO-view/-tool Trend-log Display/Browser X/X X/X E-mailing X X Web server - X Mounting Front Front 5

2.1 Master Controller RCO 721D-M RCO 721D-W Coloured graphical Display 320x240 X X Program and data memory SD-Card 2GB SD-Card 2GB Ports 2x RS232 2x RS232 1x Ethernet 1x Ethernet L-Bus-2 (Connection) RCO D-Modules RCO D-Modules Protocols BACnet-Ethernet, -IP, -PTP M-Bus TCP/IP for RCO-view/-tool BACnet-Ethernet, -IP, -PTP M-Bus TCP/IP for RCO-view/-tool Trend-log Display/Browser X/- X/X E-mailing X X Web server - X Mounting Front Front 6

2.2 Network Controller Inputs RCO 500D-M 8 *UI (0... 10 VDC, 0... 20 ma, Ni1000, NTC10K, NTC30K, Pt1000, self defined function, digital) 6*DI (Potential free- or marked contacts (24 VAC/DC), Counting input 24 VAC/DC up to 20 Hz, pulse length >1ms) RCO 500D-W 8 *UI (0... 10 VDC, 0... 20 ma, Ni1000, NTC10K, NTC30K, Pt1000, self defined function, digital) 6*DI (Potential free- or marked contacts (24 VAC/DC), Counting input 24 VAC/DC up to 20 Hz, pulse length >1ms) Outputs 4 *AO (0 10 VDC, 0 20 ma) 4 *AO (0 10 VDC, 0 20 ma) 4 *DO (230V/4A) 4 *DO (230V/4A) Program and data memory SD-Card 2GB SD-Card 2GB Ports 1x RS232 1x RS232 2xRS485 (1 for display) 1x Ethernet 2xRS485 (1 for display) 1x Ethernet Protocols BACnet-Ethernet, -IP, -MS/TP, -PTP BACnet-Ethernet, -IP, -MS/TP, -PTP RCO-C bus MODBUS Master/Slave/M-Bus Wilo / Grundfos (RS232/485) TCP/IP for RCO-view/-tool RCO-C bus MODBUS Master/Slave/M-Bus Wilo / Grundfos (RS232/485) TCP/IP for RCO-view/-tool Trend-log Display/Browser RCO 621D-S/- RCO 631D-S/X E-mailing X X Web server - X Mounting DIN-rail DIN-rail 7

2.2 Network Controller Inputs RCO 530D-M 8 *UI (0... 10 VDC, 0... 20 ma, Ni1000, NTC10K, NTC30K, Pt1000, self defined function, digital) 6*DI (Potential free- or marked contacts (24 VAC/DC), Counting input 24 VAC/DC up to 20 Hz, pulse length >1ms) RCO 530D-W 8 *UI (0... 10 VDC, 0... 20 ma, Ni1000, NTC10K, NTC30K, Pt1000, self defined function, digital) 6*DI (Potential f ree- or marked contacts (24 VAC/DC), Counting input 24 VAC/DC up to 20 Hz, pulse length >1ms) Outputs 4 *AO (0 10 VDC, 0 20 ma) 4 *AO (0 10 VDC, 0 20 ma) 4 *DO (230V/4A) 4 *DO (230V/4A) Program and data memory SD-Card 2GB SD-Card 2GB Ports 1x RS232 1x RS232 1xRS485 (1 for display) 1x Ethernet 1xRS485 (1 for display) 1x Ethernet Protocols RCO-C bus RCO-C bus Trend-log Display/Browser RCO 621D-S/- RCO 621D-S/X E-mailing X X Web server X Mounting DIN-rail DIN-rail 8

2.3 Compact-Controller RCO 550D-M Inputs 8 *UI (0... 10 VDC, 0... 20 ma, Ni1000, NTC10K, NTC30K, Pt1000, self defined function, digital) 6*DI (Potential free- or marked contacts (24 VAC/DC), Counting input 24 VAC/DC up to 20 Hz, pulse length >1ms) Outputs 4 *AO (0 10 VDC, 0 20 ma) 4 *DO (230V/4A) Program and data memory Ports SD-Card 2GB 1x RS232 1xRS485 (1 for display) Mounting DIN-rail 9

2.4 Expander I/O-Module RCO 514D-E Inputs Outputs Ports Mounting 8*DI (Potential free- or marked contacts (24 VAC/DC), Counting input 24 VAC/DC up to 20 Hz, pulse length >1ms) 6 *DO (230V/4A) I/O bus DIN-rail 10

2.5 I/O-Modules Universal-In Digital-In Analogue-Out Analogue-Out Digital-Out Digital-Out Tri-state-Out Tri-state-Out RCO 110D-S RCO 120D-S RCO 210D-S RCO 211D-S RCO 220D-S RCO 221D-S RCO 230D-S RCO 231D-S Inputs 8x UI 8x DI Outputs - - Application I-Slave I-Slave Functions 0-10V, Ni1000, NTC10K, NTC30K, PT1000, self defined functions Potentialfree- or marked contacts (24 VAC/DC), Counting input 24 VAC/DC up to 20 Hz, pulse length >1ms - - - - - - 4x AO 4x AO 4x DO 4x DO 2x Tri-state 2x Tri-state O-Slave O-Slave O-Slave O-Slave O-Slave O-Slave - - - 0... 10 VDC 0... 10 VDC 230 V, 4 A 230 V, 4 A 230 V, 4 A 230 V, 4 A Manual override No No No Auto, 0-100% No Auto, 0,1 No Auto, close, 0, open Feedback signal - - L-Bus-1 - - L-Bus-2 Yes Yes Power supply 24 VDC 24 VDC Mounting Front / DIN-rail Front / DIN-rail - Function, value - Function, value - Function, value - - - - - - - - - Yes Yes Yes Yes Yes Yes 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC Front / DIN-rail Front / DIN-rail Front / DIN-rail Front / DIN-rail Front / DIN-rail Front / DIN-rail 11

2.6 Power modules Power-Modul Power-Bridge- Modul Up to max 8 I/O-Modules RCO 721D-M L-Bus 2 1... 8 In case the load becomes higher than 12W a power modules must be used. RCO 300D-P RCO 302D-P Inputs - - Outputs - - More than 8 I/O-Modules RCO 700/720D-M RCO 300D-P L-Bus 2 Application Supply Supply Functions Power supply of the I/O-Modules + galvanical isolation L-Bus A to L-Bus B Manual override No No Feedback signal - - L-Bus 1 - - L-Bus 2 Yes Yes Power supply 24 VDC 24 VDC Mounting Front / DIN-rail Front / DIN-rail 12

2.7 Mounting variants Panel door mounting DIN rail mounting Connection of the modules T-Bus-Connector Functions: Power supply Bus connection Advantages: No wiring No wrong connections Slaves modules can be easily changed through the used Plug in Philosophy Exchange of the modules during operation 13

2.8 Operator panel RCO 640 D-S for RCO 7... Text menu Menu structure is freely configurable Indication of data points, and time schedules Alarm indication / acknowledgement Access to all Master Controller within the network Password protected 2.9 Operator panel RCO 621D-S for RCO 500, 530, 7... Text and graphical menu Like 2.8 Additional: Free configurable coloured graphical display with animation of objects Indication of graphical trend-logs RCO D Network RCO-view Master Controller I/O module 2.10 Operator panel RCO 630D-S for RCO 5... Text menu Menu structure is freely configurable Indication of data points and time schedules Alarm indication / acknowledgement Access to all Master Controller within the network Password protected 2.11 Integrated graphical display RCO 72.D-... Text and graphical menu Like 2.8 Additional: Free configurable coloured graphical display with animation of objects Indication of graphical trend-logs Messenger GSM-Modem Network Controller Modbus RS485 1... 32 14

2.12 Embedded Web server The Web-Server provides the visualisation and operation of plant data and alarms with a standard Web-Browser. With the help of the Web-Browser every PC becomes an operator terminal. The installation can be accessed at any time directly at the control panel or via Intranet or per remote control via the Internet. Simple WEB-Engineering The web pages are generated time efficient through the simple conversion of the graphical operator menu of a web enabled Controller. In a network with several Controllers only one web enabled Controller is necessary to ensure the remote control of all Controllers via the Web-Browser. 2.13 Trend-log Functionality Controller with an embedded Web-Server supports the indication of online- and historical data as graphical Trend-logs via a standard Web- Browser. Master controller with integrated display and the graphical display RCO621D-S also support the trend-log indication. 15

2.14 Single Room Controller Parametrisable Single Room Controller Operating mode: Day Night Frost Heating Cooling Heating-Cooling RCO ER440A02 4-pipe-System RCO 030A00 Coupling relay for 3-stages fan RCO ER450A02 2-pipe-System Integration in the RCO-Network Modbus RS485 1... 32 Modbus RS485 1... 32 Connections / Out-/Inputs: 24 VAC Modbus Heating (0... 10 VDC or ON/OFF) Cooling (0... 10 VDC or ON/OFF) Fan (0... 10 VDC) (Stages with Modules RCO 030A00) Window contact Presence button Connections / Out-/Inputs: 24 VAC Modbus Heating (0... 10 VDC / ON/OFF or tri-state) Cooling (0... 10 VDC / ON/OFF or tri-state) Fan (0... 10 VDC) (Stages with Modules RCO 030A00) Window contact Presence button 16

3. Building Management Software RCO-view Web-based Building Management Software Technology Apache Server SQL Data base Standard browser (Firefox from 3.6, IE 8.0) MS.Net Framework Technology Features Animated visualisations for graphical operations Alarm and messenger management Access management for user and user groups Time Schedule management Event logs Archiving and analysis of historical data Online Trending Multi-Site-Handling 17

3. Building Management Software RCO-view 3.1 Animated visualisations for graphical operations Features Monitoring of values Change of values, e.g. Setpoints, time schedules Animated graphics 2D/3D 18

3. Building Management Software RCO-view 3.2 Alarm Management Features Priority and event controlled alarm and messenger management Time and priority dependent dispatch of / to emails sms (via Provider) printer client (Alarm Window) Alarm Log-Files 19

3. Building Management Software RCO-view 3.3 Access management for user and user groups Features Access control through username and password Definition of user groups and user Assignment of different rights for each user and user group for projects, pages down to each widget. 20

3. Building Management Software RCO-view 3.4 Time Schedule management Features Weekly time schedules Numbers of time schedules not limited 20 on/off time pairs per day Values can be assigned to the time pairs Yearly time schedules Numbers of time schedules not limited Yearly time schedule can be connected to the weekly schedule 21

3. Building Management Software RCO-view 3.5 Event monitoring with Log-Files Features Event logs for: Value changes Client changes Alarms Commands Filter function like time, user Download for CSV or XML Access control for event logs 22

3. Building Management Software RCO-view 3.6 Integration of IP cameras Features Integration of IP cameras Event driven fade in of live streams 23

3. Building Management Software RCO-view 3.7 Historical data, Online Trending Features Archiving of historical Data 48 hour trend for all server data points Storage in SQL data base Free definable archiving on BMS level Storage in SQL data base Free definable archiving on Controller level. Automatic transfer of the csv-files into the SQL data base Frei definable Live-Logs Visualisation, analysis Graphical visualisation of up to fife data points within a web browser as line a bar graph Export of the data as csv-file Export of the picture as jpg Free selection of data points and colour assignment via selection window Adjustable time slot for indication Tracking function (indication of values) 24

3. Building Management Software RCO-view 3.8 Intuitive engineering Features Time-saving engineering through Online or offline data point assignment Drag and drop for the positioning of the animations Widget library for 2D and 3D animations Export function for pages, projects Pages free configurable 25

4. Efficient Engineering RCO-tool The Controlesta RCO-tool serves the efficient and economic programming of Controlesta RCO-D installations. It s supports the engineering process starting from the configuration via the programming until the commissioning and documentation. 4.1 Configuration Hardware configuration Alarms Time schedules Histories Interactive menus Embedded Web-Server BACnet 4.2 Programming Graphical and text programming can be done in parallel Program and macro module library Generation of individual program and macro modules Online programming Simple protocol implementation Hardware configuration 26

4. RCO-tool (Engineering) 4.2 Commissioning Online Scanning of macro-modules Scanning of the I/O-Modules Alarm Info Automatic generation of EDE-files 4.3 Documentation Storage of the project file Export into ASCII-Format Preparation in Excel or Word / Export to Printer - Plant configuration - Project tree - Menu - etc. 27