FLEX 2 NEW. Key points. 3D Confocal Raman, 2 lasers, fiber based, AFM combined

Similar documents
SPECTRUM. The world s first fully automated Raman AFM. AFM - confocal Raman - SNOM - TERS AFM KPFM. Raman. AFM-Raman characterization of PS-PVAC

Depth analysis for laminated film by confocal Raman mapping

MonoVista CRS+ Raman Microscopes

Confocal Raman Systems SPECTROSCOPY GROUP

Confocal Raman Imaging with WITec Sensitivity - Resolution - Speed. Always - Provable - Routinely

WITec Raman Spectroscopy Solutions

Modular Approach and Customized solutions (near field, UV-VIS, etc.)

Confocal Raman Microscope RAMOS

Attachable to other Advanced analytical tools (e.g AFM, XRD, SEM etc.) Detect and measure deposits in liquid as it is (Particle ID Detection)

Thermo Scientific DXR2 Raman Family

Operating Procedure for Horiba Raman Microscope

Introduction to. 3D Scanning Confocal Microscope with Spectrometer

Renishaw invia Raman Microscope (April 2006)

Versatile laser Raman Spectrometer. RMP-500 series

(Fiber-optic Reosc Echelle Spectrograph of Catania Observatory)

NIRvana: 640ST. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

LS-785 High Throughput Lens Spectrograph User Manual

Easy integration into complex experimental setup

Physics 625 Femtosecond laser Project

Modular Raman Spectrometers

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

Chemical Characterization of Diverse Pharmaceutical Samples by Confocal Raman Microscopy

Certus Light. NanoScanTechnology. Basic Datasheet. reasoned innovations. Entry Level Scanning Probe Microscope. Scanning Probe Microscope

NIRvana: 640. Applications: Nanotube fluorescence, emission, absorption, non-destructive testing and singlet oxygen detection

Back Illuminated Scientific CMOS

Acton Research SpectruMM TM Complete Spectroscopic- Acquisition Systems

The Anfatec Level AFM a short description. Atomic Force Microscopy - approved devices for affordable prices

DSU Start-Up instructions

TRiCAM APPLICATIONS KEY FEATURES. Time Resolved intensified CAMera. TRiCAM 13001A01 31/10/2013

ihr Series horiba.com/osd Research Grade Spectrometers Simply the best imaging spectrometers with no compromise

195 mm Focal Length, nm, Echelle Spectrograph. Specifications. Wavelength range (nm) Focal length (mm) 195.

Imaging Spectrometers

Mightex Simply Brighter. Polygon400 Multiwavelength Dynamic Spatial Illuminators (Part Numbers: DSI-x-xxxx-xxxx-xxx-xxx) PRODUCT DESCRIPTION FEATURES

MultiView 2000 TM. The First Tip and Sample Scanning Probe Microscope. The Next Evolution in SPM. The Next Evolution in SPM

Certus Optic. NanoScanTechnology. Basic Datasheet. reasoned innovations. Integrated Optical and Scanning Probe Microscope

Frequently Asked Questions: excelon Back Illuminated CCD/EMCCD Cameras

Spectrograph overview:

LASERS FOR ANALYTICAL INSTRUMENTATION

Minimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.

High Resolution Low Light Cameras

Video frame rates and higher to efficiently synchronize with high repetition rate lasers

Hyperspectral Microscope based on Imaging Fourier transform Spectrometry. Dr. Li Jianping, Claude. Copyright: Claude.

SYNCERITY TM 1024 x 256

Frequently Asked Questions: Princeton Instruments excelon TM CCD and EMCCD Cameras

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

sensicam qe cooled digital 12bit CCD camera system

Apex High Performance Spectrometer

TuCam. Features and Benefits. Andor TuCam - High Performance, Two Camera Imaging Adapter. Specifications Summary. Applications Guide

TissueFAXS SL Confocal high throughput configuration (actual appearance of the product may differ)

High Resolution BSI Scientific CMOS

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

Overview. Etalon-Based FSRS Setup APPLICATION NOTE

ProEM -HS:1024BX3 FEATURES BENEFITS

AP* Optics Free Response Questions

Raman Lab - Laser 1 operation

LIFA. SPECIFICATIONs. Fluorescence Lifetime Attachment LIFA14001A02 25/02/2014

Optics Vac Work MT 2008

PGx01 series. High Peak Power. Available models

Chemistry Instrumental Analysis Lecture 6. Chem 4631

Spectral imagers for nanosatellites

LASERS FOR ANALYTICAL INSTRUMENTATION

Raman Spectrometer Installation Manual

Introduction to Raman spectroscopy measurement data processing using Igor Pro

4.2 Megapixel Scientific CMOS Camera

Spectrographs. C. A. Griffith, Class Notes, PTYS 521, 2016 Not for distribution.

Optical Sectioning. Bo Huang. Pharmaceutical Chemistry

Optical Ptychography Imaging

PHYSICS 213 PRACTICE EXAM 3*

20 MHz/16-bit readout 61 fps rate at full-frame resolution. Use ROI/binning for hundreds of frames per second.

UHD 185 FAQs. Optical System

COBRA Slim Linescan Illuminator

P recise Eye. High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection.

Development of Ultrafast CXRS system in Heliotron J. Graduate School of Energy Science Kyoto University LU XIANGXUN 03/15/2016

LIFA KEY FEATURES APPLICATIONS. Fluorescence Lifetime Attachment LIFA 15001A02 16/03/2015

Newton EMCCD. Specifications Summary 1. Output node well depth (typical) High Sensitivity mode Electron Multiplying mode

FEATURES BENEFITS 1024 x 1024 Imaging Array High resolution imaging and spectroscopy

Navigator. The Navigator

COBRA Slim Linescan Illuminator

PIXIS: 512 IMAGING GROUP

PI-MAX 4: 1024 EMB. Applications:

Leica TCS SPE. Spectacular Imaging! Technical Documentation

WITec Suite FIVE. Project FIVE Control FIVE Project FIVE+

Tutorial Solutions. 10 Holographic Applications Holographic Zone-Plate

idus 401 Series Specifications Summary Active pixels 1024 x 127 Register well depth (typical) 1,000,000 e - Maximum spectra per sec 88

PI-MAX 4: 1024 x 256

Precise Eye High Mag Fixed Lenses

Series Spectrometers PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Leica TCS STED. The Fast Track to Superresolution Technical Documentation

X-Ray fluorescence and Raman spectroscopy

SeBa Digital Imaging Systems

ZOOM STEREOMICROSCOPE SZ61/SZ51. For Biological Use. The Comfort Zone

DV887 (back illuminated)

Certus Standard. NanoScanTechnology. Basic Datasheet. reasoned innovations. Basic Configuration of Scanning Probe Microscope

Astronomical spectrographs. ASTR320 Wednesday February 20, 2019

LIGHT SHEET MICROSCOPE. Alphα NEW GENERATION. Ground Breaking Technology For Selective Plane Illumination Microscopy

Fluorescence Microscope with Spinning Disk Confocal and Total Internal Reflection Fluorescence Modules

ProEM -HS:1KBX3-10µm

Throughput of an Optical Instrument II: Physical measurements, Source, Optics. Q4- Number of 500 nm photons per second generated at source

ProEM -HS:1024BX3 FEATURES BENEFITS

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Transcription:

FLEX 2 3D Confocal Raman, 2 lasers, fiber based, AFM combined NEW Key points Compact size 2 lasers, easily switchable 2 confocal operation modes, easily switchable : High Spatial Resolution 35 nm High Spectral Resolution.75 cm -1 High Throughput 4%

Smart design for easy use All Fibers always connected No fiber exchange or realignment needed 2 detection fibers combined to bundle for spectrometer input FLEX 2 15 core High Throughput 5 core High Resolution 15 core 5 core Spectrometer 2 laser input fibers 1 Sample 2 Motorized or Manual external shutter and power control spectrometer fiber All switching by sliders Confocal mode switch Detection polarization Raman Unit Filter set switch polarization Microscope mode switch switch shutter Microscope Unit Convenient magnetic hatches for easy access (e.g. changing laser line/raman intensity ratio, polarization orientation in detection channel,etc.) TVCCD, Digital camera, scientific CMOS camera, trinocular with eyepieces 1

High quality optical Microscope White LED illumination Wide observation modes choice: Bright Field, Fluorescence (optional), Polarization (optional), etc. Sample observation/raman measurement mode switch Compatible with standard Upright microscope frame and Free Space granite microscope frame foradvanced operation modes. Piezo-stage AFM Standard Upright Microscope For handle or Step-Motor positioner,piezo-stage scanner. Free Space Granite Frame Microscope Long travelling (1515 mm) Step-Motor positioner, Upright, Transmission and Inverted microscope configurations.large working space, AFM combined. Free arrangement on optical table due to fiber design. http://www.tokyoinst.co.jp/ 2

Granite Frame Microscope Large working space Flexible custom equipment and configuration Long stroke (25 mm) with accurate knob control Broad working space 39(W)36(D)25 or 36(H) mm Granite frame for thermal and temporal stability Fine microscope focusing knob (3 mm) AFM choices Best performance for AFM-Raman, TERS ( Tip Enhanced Raman Spectroscopy), SNOM (Scanning Near Field Optical Microscope) "SMART" AFM for Upright microscope configuration. "CombiScope" AFM for Upright, Inverted and Transmission microscope configurations. 3

AFM-Raman Structures AFM-Raman reflection structure. Microscope objective lens and AFM cantilever are at the top of the sample. Microscope objective lens 1 Objective lens Sample AFM tip AFM cantilever AFM-Raman transmission structure. AFM cantilever is on the top,microscope objective lens is on the bottom of the sample. Sample AFM tip AFM cantilever Objective lens Microscope objective lens 1 Transmission SNOM structure. Objective lenses are on the top and bottom of the sample. SNOM probe is in between. Top Microscope objective lens Top objective lens Sample SNOM probe Hollow pyramid SNOM probe Bottom objective lens Bottom Microscope objective lens http://www.tokyoinst.co.jp/ 4

Spectrometer choices Throughput, Spectral resolution, Calibration convenience 35 mm imaging Focal length,mm 35 415 52 F# 3.8 4.3 5.4 Dispersion 1 a),nm/mm 2.37 1.82 1.55 Dispersion 2 b),cm -1 /pix 2.4 1.59 1.33 415 mm SHR Imaging Mirror coating AI,Silver, Gold,BB c) AI AI,Silver, Gold,BB c) Number of gratings 4 3 4 SHR d) (Echelle grating) 52 mm imaging,shr Automatic calibration (optional) Size (W D H),mm 51 395 2 535 4 26 635 339 27 a) - for grating 12 G/mm at 546 nm; b) - per one CCD pixel of 26 m size; c) - Dielectric Broadband coating; d) - Super-High Resolution with echelle grating option (FWHM <.5 cm -1 ) CCD detector -1 1 BVF BEX2-DD BU BR-DD TE cooled spectroscopy CCD: Minimum Temperature : -1 water, -8(air) 2626 m pixel size QE (%) 5 OE FI Active (pixels) BU BVF OE FI BR-DD BEX2-DD DU42A 124 255 2 7 12 Wavelength (nm) DU41A 124 127 Other CCD (including EM-CCD), APD detectors are available on request. 5

Data examples Si device 4 counts 5 4 3 2 1 Si wafer Raman spectrum. Exposure.5 sec 532nm laser power 12 mw 2 4 6 8 Raman shift,1/cm 1 High system sensitivity permits fast 3D Raman imaging at 52 cm -1. Mapping faster than 3 ms/point with full spectrum saving in every mapping point is possible (with optional 3 MHz ADC CCD) Multilayer graphene 8 6 4 2 2 4 6 8 G-band intensity at around 1582 cm -1.4.3.2.1 1 3 counts 1.6 8 1.59 6 1.58 4 1.57 2 1.56 1.55 2 4 6 8 G-band peak position Sample courtesy of Prof. Dong Wang,Institute of Chemistry Chinese Academy of Sciences 1 3 counts 8 6 4 2 2 4 6 8 G-band FWHM 15 14 1/cm 8 6 4 2 2 4 6 8 2D-band intensity at around 2685 cm -1 8 4 1 1 3 counts 8 2.695 6 4 2.685 2 2.675 2 4 6 8 2D-band peak position 1 3 counts 8 6 4 2 2 4 6 8 2D-band FWHM 65 6 55 5 45 1/cm 2D Raman images 532 nm laser. FitPeak software option applied. Single Lorentzian curve fitting. Pharmaceutical tablet counts Tablet surface 1.51 5 2.1 6 785 nm laser 1.51 1.1 6 5 532 nm laser 1.1 6.51 5 counts Tablet inside 532 nm laser 785 nm laser Raman spectra from pharmaceutical tablet. Strong fluorescence background with 532 nm laser Spectra are throughput corrected.51 6 8 6 4 2 1 2 3 Raman shift,1/cm 4 2 1 3 counts 8 6 4 2 1 2 3 Raman shift,1/cm 4 3 2 1 1 3 counts 2D Raman images of the tablet at 47 cm -1 (left) at 16 cm -1 (right). 785 nm laser 2 4 6 8 2 4 6 8 http://www.tokyoinst.co.jp/ 6

Main Specifications Number of lasers: 2 (standard set 532 nm, 785 nm). Optional laser wavelength: 355, 473, 488, 632.8, 83, 976 nm. Detection fiber bundle: 2 fiber cores -5 m core for High Resolution (HR) mode; -15 m core for High Throughput (HT) mode. Optional fibers available. Standard scanner - piezo-stage X-Y-Z: -1 m travel range; -5 nm position repeatability. Optional: other travel ranges, step-motor scanner, AFM scanner. Wavenumber range (cm -1 ) Dispersion a) (cm -1 /pix) Spectral Resolution a), b) FWHM, typ (max) (cm -1 ) Spatial resolution b), c) X-Y (nm) 532 nm 54 1.3 (at 546 nm) 2 (2.6) (at 546 nm) 35 785 nm 43.49 (at 812 nm).75 (1) (at 812 nm) 5 Spatial resolution b), c) Z (nm) 9 a) with spectrometer f=35 mm, grating 18G/mm, entrance slit 3 m, CCD pixel 26 m. b) fiber 5 m core ("High Resolution" confocal mode) c) with objective lens 1X NA=.95 9 Size:Microscope with "Flex2" Raman unit footprint Olympus microscope frame:2738 mm Free Space Granite frame:3958 mm Standard 35 mm spectrometer footprint: 51395 mm Power consumption: 1 V15 A or 22 V7.5 A Advanced Software Full system control and 1-2-3D data analysis and visualization; Full Raman spectrum saving in every mapping point; Simultaneous multidetectors readout; Possibility to select mapping area on TV-CCD microscopic sample image; Fast scanning algorithm; Spectra stitching; Throughput correction; Macro-spot mapping; Image accumulation; Spectrum fitting with up to 5 Lorentzian or Gaussian curves; Deconvolution processing for 1D or 2D data Simultaneous AFM topography and Raman spectroscopy,same area and TERS functions. Throughput correction lamp option Head Office:6-18-14 Nishikasai Edogawa-ku, Tokyo 134-88 Phone +81-3-3686-4711 Fax +81-3-3686-831 Osaka Office:4-1-46 Miyahara Yodogawa-ku, Osaka 532-3 Phone +81-6-6393-7411 Fax +81-6-6393-755 WEB Site : http://www.tokyoinst.co.jp/ Due to constant improvement and development we reserve the right to change specifications without prior notice. It is forbidden to reprint the contents of this brochure in part or in full without permission. Manufacturer names and product names listed in this catalog are trademarks or registered trademarks of their respective owners.