Standard Bellows Metering Pumps

Similar documents
Compact Bellows Pumps

Mini Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

MAX FLUID TEMPERATURE

SERVICE PARTS MANUAL

Dishmachine Division Please call for pricing or

EPX2155. Piston Pump. Owner s Manual. Model Numbers: Stand Upright Cart Low Boy Cart

SECTION 8 - ULTRA & ULTRA-C PARTS CATALOGUE

EPX2555 Advantage Series Piston Pump

8 Submersible Motors Hi-Temp 75

8 Submersible Motors Standard

MK-101 TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER:

98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98

SERVICE PARTS MANUAL

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Parts / Spares Reference Sheet

HOW TO ORDER SWIVEL JOINTS

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

GOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S.

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

GPX 1250 Gas Piston Pump

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

Type 330SA High-Performance Electric Actuator

Timken Lubrication Delivery Systems. Friction management solutions SM to keep systems running smoothly

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

Bartels Micropumps. DE Seite 14

Ball Screw Actuator Models Advantages:

AIR CUSHION TECHNOLOGY

9. SPARE PARTS -43- STEAM SYSTEM (OPTION ONLY) Steam Switch Water Solenoid

RA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols

1220 Self-Contained Carpet Extractor

NDP-50 Series Specifications

13AN77KG011 Pony (2009) Page 1 of 21 Engine Accessories

Husqvarna X4000. Illustrated Parts List Jun 2009

3", 4"and 5" Adjustable Angle Industrial Thermometers Maximum utility for installation Head can be rotated 360 Stem positioning over 180

17AE2ACG011 MUSTANG COLT RZT 42 (2008) Page 1 of 22 Deck Lift & Controls

ENCORE S2426 and L2426

Oval Gear Meter OGM PLUS

LIST NO. F409 ROTARY HAMMER. Model DH 28PD (E1) DH28PD 22% TU Rev.1

Classic Collet Knobs. Standard Product Variety. Introduction. Possible Customization

Stainless Steel Submersible Pumps DATA BOOKLET. ISO 9001 Company. 60 Hz. Pumping Solution

Bartels Micropumps. ( ) rev mp6 double actuator micropump. Functional principle of mp6. mp5 smallest available plastic micropump

Loader Directional Control Valve

Data is only for informational purpose. All specifications are subject to change without notice.

21AE662M cc Elec Roto-Tiller (2008) Page 1 of 13 Drive System

F-1000 DIGITAL PADDLEWHEEL FLOWMETER

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Screw. Nut Guide. Features

FOR TUBE FITTINGS OR-910N OR-910NA 5/8" 7/8" ".097" 11/16".863".116" 318-A02-1C. STOCKED O-RINGS in SPECIAL COMPOUNDS

UNITED STATES MEXICO CANADA

CH-PVDF RED & NATURAL PVDF Kynar SCHEDULE 80 PIPE, VALVES & FITTINGS. Effective Nov. 16, 2015 Supersedes CH-PVDF-1113 dated Nov.

Pressure switch KP. Data sheet

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

MK-212 SERIES PARTS LIST MODELS: MK Part # MK SPCL Part # SPCL MK Part #

Flowtronic D 607 Series

NDP-20 Series Specifications

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

1/2

Timken Lubricant Delivery Systems. Friction management solutions to keep systems running smoothly

Optical Encoders. Sold & Serviced By: Toll Free Phone: Toll Free Fax:

"PVL" SERIES. Fixed Displacement - Single PVL1. Up to 5 MPa (730 PSI), 10.6 cm /rev (.647 CU.IN./rev)

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS

Pressure switch KP. Data sheet

JOHN GUEST SPEEDFIT FITTINGS

Plumbing Brass Specification Guide

CATALOG OF REPLACEMENT PARTS MODEL FP400 FOOD PROCESSOR. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

STEEL PIPE NIPPLES G1616 STANDARD BLACK STEEL NIPPLES ITEMS HIGHLIGHTED

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Stainless steel hygienic butterfly valves. F250 for imperial tubing. F251 for metric tubing.

SERVICE PARTS MANUAL

Pronto Air Personal Transporter

Prodigy Color-on-Demand System Generation III

ASTRO CIRCULATORS. IRON BODY CONSTRUCTION Model No. Part No. Connection List Price Wt.ea.lbs. ASTRO

Illustrated Parts List for VMAC System V Ford SuperDuty F250-F L Gas V8 Engine

E SERIES CIRCULATORS

FLEX-PRO. Peristaltic Metering Pump SERIES A3V. Operating Manual. ProSeries. by Blue-White Ind.

DM28 - Economical Digital Process and Strain Gauge Panel Meters

Model RFM. Model RFM. Materials and Specifications. Residential Fire Meter Sizes 3/4", 1", 1-1/2" and 2" Features 1" RFM 50 2" RFM 160

Rider AMP TM. Parts Manual. Model In. S.D. Deck /09 Printed in USA

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

61F-GP-N8D. Model Number Structure. Ordering Information. Conductive Level Controller. Model Number Legend. List of Models

shop online:

SOCKET FITTINGS. Nom. BLACK PP 6111 NATURAL PP Nom. BLACK PP 6117 NATURAL PP Nom. BLACK PP 6133 NATURAL PP 6233 CHEMTROL CUSTOMER SERVICE

T E M P O S O N I C S I I I INSTALLATION

Close-coupled centrifugal pumps

Assembly and Maintenance

MK-101 TILE SAW OWNER'S MANUAL, PARTS LIST & OPERATING INSTRUCTIONS

Model. MITSUBISHI Industrial Sewing Machine Parts Catalog ( ( ( ( ( 170 INDEX Page. From the library of: Superior Sewing Machine & Supply LLC

RD 100. Spare parts list. RD 100 s/n BES Construction Tools PC AB No

T E M P O S O N I C S I I I INSTALLATION CAUTION! B. CONNECTORS RG Connector. D6 Connector: INTEGRAL CABLE P Integral Cable

SERIES 1300 Quality Design Features Assure Long, Trouble-Free Service

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

Fits 1 3/4" Resilient Rings. Part # Shaft Height A" 92-A /4" 4.4" 92-A /4" 4.6" Fits 2 1/2" Resilient Rings. Part # Shaft Height A"

LCC Pump Series - Wear Resistant, High Performance Slurry Pumps

Technical Specification _5.0. Concertor N/EA/DP

imag 4700 Series FLANGED MAGMETER

060-Hardware. Clamps and Brackets Hose Clamps

ZT 1844XL & ZT 2148XL

14AZ809H063 GTX2446 (2003) Page 1 of 26 Deck Assembly H 46 Inch

Transcription:

Standard Bellows Metering Pumps Bellows Metering Pumps operate on a positive displacement principle. Pumps are designed to displace both corrosive and noncorrosive fluids. Accurate to ± 0.5% from stroke to stroke, when pump is set 50% to 100% of full stroke. Discharge pressure is maintained over the entire flow range of the pump. Poppet valves are used to prevent back flow; and springs are available to provide a positive shutoff, preventing siphoning through the pump in applications where a positive suction head exists. Typical applications include film and x-ray processors, silver recovery systems, wafer and silicon chip washers and processors, detergent dispensers, blood analyzing equipment, industrial floor scrubbers, thermo therapy equipment, waste removal systems, and wastewater and water treatment systems. Features: Repeatability from stroke-to-stroke to ± 0.5% Dry run capability Self-priming No dynamic seals Corrosion resistant Long, maintenance-free operation Contents Pages Overview... 2-4 Pump Selection... 5-16 Part Selection Guide...17 Options...18 Accessories...19 Replacement Kits... 20-23 GRI Standard Bellows Pumps Overview 0119 012219 Page 1

Standard Bellows Metering Pumps Overview Bellows metering pumps operate on a positive displacement principle. Pumps are designed to displace both corrosive and noncorrosive fluids. Accurate to ± 0.5% from stroke to stroke, when pump is set 50% to 100% of full stroke. Discharge pressure is maintained over the entire flow range of the pump. Poppet valves are used to prevent back flow; and springs are available to provide a positive shutoff, preventing siphoning through the pump in applications where a positive suction head exists. Features: Repeatability from stroke-to-stroke to ± 0.5% Dry run capability Self-priming No dynamic seals Corrosion resistant Long, maintenance-free operation Typical applications include film and x-ray processors, silver recovery systems, wafer and silicon chip washers and processors, detergent dispensers, blood analyzing equipment, industrial floor scrubbers, thermo therapy equipment, waste removal systems, and wastewater and water treatment systems. Bellows Metering Pump Operation: The Bellows Metering Pumps operate on a positive displacement principle. The rotation of the motor shaft is transmitted into an up and down motion through a lever pivot crank mechanism. This motion provides a continuous squeezing and relaxing force on a bellows module, forcing fluid in and out of the module. Discharge pressure is maintained over the entire flow range of the pump. Optimum Operating Conditions: Optimum operating conditions consists of a 6 minimum suction lift and a discharge head of not less than 6. Pumps must be mounted vertically with the valve body at the top to obtain maximum metering accuracy. GRI Standard Bellows Pumps Overview 0119 012219 Page 2

Flow Rate and Discharge Pressure The flow rate of each bellows module is regulated by three factors: 1. Diameter of the bellows, 2. Speed of the gear motor, 3. Adjustment of the module stroke length. Bellows are available in several different diameters. The full stroke displacement and discharge pressure of the pump is dependent on the size of the bellows as shown below: Size 1 /2 1 1 1 /2 Full Stroke Displacement in ml Maximum Discharge Pressure (psi) 2 1 /2 STD 2 1 /2 BOJ.5 5 10.5 55 27.5 50 40 20 5 5 Flow Adjustment: The flow rate of all bellows pumps can be adjusted by modifying the length of the discharge stroke. Adjustments can be made down to 10% of full stroke on all models except 1 2 models which are limited to 20% of full stroke. Two styles of adjustment mechanisms are available. Note: Best priming and metering accuracy occurs when the stroke length is 50% or greater. Standard Crank Adjustment cannot be made while pump is operating. An adjusting screw changes the stroke length of an eccentric crank. BEL O JUST Can be adjusted while the pump is operating. A knob regulates drive arm motion which modifies the stroke length of the bellows module. GRI Standard Bellows Pumps Overview 0119 012219 Page 3

Pump Specifications: Flow Rates Range from 3.9 ml/min to 3000 ml/min, depending on pump configuration, gearmotor speed and stroke length. Discharge Pressures Range from 5 to 50 psi depending on bellows size. Max Fluid Temperature 140 F (60 C) Note: Reduce pressure rating by 50% for fluid temperatures over 120 F (49 C). Viscosity/Slurries Maximum fluid viscosity is 5,000 centistokes. Poppet valves can handle fine slurries. Duckbill valves are recommended for heavy slurries or fibrous materials. Heavy slurries should be flushed from the pump before shutdown. MAXIMUM DRY AND WET PRIMING SPECIFICATIONS Feet (Meters) Bellows Sizes Dry Prime 50% of Full Stroke Dry Prime 100% of Full Stroke Wet Prime 50% of Full Stroke Wet Prime 100% of Full Stroke 1 / 2 2.5 (.76) 8.67 (2.64) 5.83 (1.78) 17.17 (5.23) 1 3.08 (.94) 8.33 (2.54) 6.25 (1.91) 14.25 (4.34) 1 1 / 2 4.33 (1.32) 11.00 (3.35) 9.58 (2.92) 20.58 (6.27) 2 1 / 2 9.17 (2.80) 18.50 (5.64) 15.25 (4.65) 27.58 (8.41) Gearmotors: Catalog gear motors are available in 115V, 50/60 Hz or 240V, 50/60 Hz. Standard motor speeds are 39, 60, 90 and 165 RPM at 60 Hz. Motors are UL recognized and continuous duty rated with a minimum life expectancy of 2000 hours. Perpetual running of motor is not recommended. If a non-stop application is required, the Gorman-Rupp Industries Heavy-Duty Bellows Metering Pump is recommended. Materials in Contact with Solution: Connectors Polypropylene O-Rings (Elastomers) EPT/EPDM or Viton /Fluoroelastomer Poppet/Duckbill Valves EPT/EPDM or Viton /Fluoroelastomer Bellows Standard Polypropylene Materials Additional materials available, refer to OEM Section. Pump Selection: From the following pages (5-16) select a bellows size that meets your pressure requirements. Select a model with the bellows size that provides your required flow while operating closest to full stroke capacity. Best metering accuracy occurs when bellows modules operate at 50% or more of maximum output. For 24 hour continuous duty service, use one of the heavy-duty models. Select a valve and O-ring combination and tubing connectors for each bellows from the Part Selection Guide, page 17. Specify duckbill valves if heavy slurries or fibrous materials are being pumped. Refer to the Chemical Resistance Section to help determine compatibility. GRI Standard Bellows Pumps Overview 0119 012219 Page 4

Single Bellows Pumps Standard & BEL O JUST Models Order notes: When ordering a single bellows model, add one X code for valve and O-ring material selection and one T code for connector selection from the Bellows Part Selection Guide on page 16. Example: 13300-007 (1 bellows model) with EPT/EPDM poppet valves and O-rings and elbow connectors for 3 8 I.D. Tubing would be ordered as 13300-007 X-112 T-008. *Amp values for 240V will be approximately 50% of 120V values shown above. MODEL SPECIFICATIONS Standard Single BEL O JUST Discharge Maximum Flow Gallons (Liters) Bellows Strokes per minute ml per minute per hour Max. Electrical Approx. Model Number Model Number (Motor RPM) per module per module Pressure Amps* Wt. 120V/60 Hz 240V/60 Hz 120V/60 Hz 240V/60 Hz Diameter PSI 120V 110V/50 Hz 220V/50 Hz 110V/50 Hz 220V/50 Hz Inches 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz (kg/cm2) 60 Hz 6.2 7.4 13960-022 13960-024 14280-006 14280-007 1 2 32.5 39 16.3 19.5 for 24 hrs. for 24 hrs. 50 1.1 5.5 (23.4) (28.1) (3.7) 26.1 31.4 13960-027 13960-028 14280-009 14280-014 1 2 137 165 68.8 82.5 for 24 hrs. for 24 hrs. 50 1.1 5.5 (99.0) (118.8) (3.7) 13300-007 13300-008 14250-005 14250-006 1 32.5 39 162.5 195 13300-009 13300-010 14250-007 14250-008 1 50 60 250.0 300 13300-045 13300-046 14250-014 14250-015 1 75 90 375.0 450 13300-047 13300-048 14250-016 14250-017 1 137 165 687.5 825 13325-001 13325-002 14251-001 14251-002 1 1 2 32.5 39 341.3 409.5 13325-003 13325-004 14251-003 14251-004 1 1 2 50 60 525.0 630 13325-005 13325-006 14251-005 14251-006 1 1 2 75 90 787.0 945 13325-031 13325-032 14251-007 14251-008 1 1 2 137 165 1443.8 1732.5 12950-003 12950-004 N/A N/A 2 1 2 32.5 39 1787.5 2145 2.6 3.1 40 (9.8) (11.7) (2.9) 4.0 4.8 40 (15.0) (18.0) (2.9) 5.9 7.1 40 (22.5) (27.0) (2.9) 10.9 13.1 20 (41.2) (49.5) (1.5) lbs. 1.1 5.5 1.3 5.5 1.1 5.5 1.1 5.5 5.4 6.5 20 (20.5) (24.6) (1.5) 1.1 5.5 8.3 10.0 20 (31.5) (37.8) (1.5) 12.5 15.0 20 (47.2) (56.7) (1.5) 22.8 27.5 10 (86.6) (103.9) (.73) 28.3 34.0 5 (107.3) (128.7) (.37) 1.3 5.5 1.1 5.5 1.1 5.5 1.1 5.5 GRI Standard Bellows Pumps Overview 0119 012219 Page 5

Typical Dimensions Single Bellows Pumps Standard & BEL O JUST Models 2 " Model 1" Model 1.44 (11.18) BEL-O-JUST MODEL ONLY 7.41 (188.21).44 (11.18) BEL-O-JUST MODEL ONLY 3.27 (83.06).25 (6.35) 7.69 (195.33) 3.27 (83.06).25 (6.35) 7.34 (186.44) FLOW 6.99 (177.55) FLOW 7.56 (192.02) 5.16 (131.06).44 (11.17) 3.75 (95.25) BETWEEN #10-32 HOLES #10-32 THREAD 4-MOUNTING HOLES 5.16 (131.06) 1.56 (39.62) 1 1 2 " Model.44 (11.17) 3.75 (95.25) BETWEEN #10-32 HOLES #10-32 THREAD 4-MOUNTING HOLES 1.56 (39.62) 2 1 2 " Model.44 (11.18) BEL-O-JUST MODEL ONLY 7.69 (195.33) 7.25 (184.1) 3.27 (83.06).44 (11.18) BEL-O-JUST MODEL ONLY FLOW 3.27 (83.06).25 (6.35).25 (6.35) 7.34 (186.44) FLOW 8.00 (203.2) 7.56 (192.02) 5.16 (131.06).44 (11.17) 3.75 (95.25) BETWEEN #10-32 HOLES #10-32 THREAD 4-MOUNTING HOLES 6.34 (161.0) 1.56 (39.62).44 (11.17) 3.75 (95.25) BETWEEN #10-32 HOLES #10-32 THREAD 4-MOUNTING HOLES 1.56 (39.62) Dimensions in Inches (Dimensions in Millimeters) GRI Standard Bellows Pumps Overview 0119 012219 Page 6

Two Tandem Bellows Pumps Standard & BEL O JUST Models Two tandem bellows pumps feature modular design for proportioning separate liquids. The flow rate of each bellows module is independently adjustable. Bellows modules are assembled out-of-phase for most efficient power usage. Total output of pump is limited to 3,000 ml/min. BEL O JUST TWO TANDEM MODEL Order notes: When ordering a two tandem bellows model, add one X code for valve and O-ring material selection and one T code for connector selection from the Bellows Part Selection Guide on page 16. Example: 13726-014 (1½ x 1½ two tandem model) with EPT/EPDM poppet valves and O-rings and elbow connectors for 3 8 I.D. tubing would be ordered as 13726-014 X-115 T-008 X-112 T-008. *Amp values for 240V will be approximately 50% of 120V values shown above. MODEL SPECIFICATIONS Standard Single BEL O JUST Discharge Maximum Flow Gallons (Liters) Bellows Strokes per minute ml per minute per hour Max. Electrical Approx. Model Number Model Number (Motor RPM) per module per module Pressure Amps* Wt. 120V/60 Hz 240V/60 Hz 120V/60 Hz 240V/60 Hz Diameter PSI 120V 110V/50 Hz 220V/50 Hz 110V/50 Hz 220V/50 Hz Inches 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz (kg/cm 2 ) 60 Hz 13701-021 13701-022 14324-029 14324-030 1 x 1 50 60 13701-019 13701-020 14324-027 14324-028 1 x 1 75 90 13726-016 13726-017 15904-003 15904-004 1 1 2 x 1 1 2 50 60 13726-014 13726-015 15904-001 15904-002 1 1 2 x 1 1 2 75 90 250.0/ 300.0/ 3.96/3.96 4.75/4.75 20/20 250.0 300.0 (15.0/15.0) (18.0/18.0) (1.50/1.50) 375.0/ 450.0/ 5.94/5.94 7.13/7.13 20/20 375.0 450.0 (22.5/22.5) (27.0/27.0) (1.50/1.50) 525.0/ 630.0/ 8.32/8.32 9.98/9.98 10/10 525.0 630.0 (31.5/31.5) (37.8/37.8) (.73/.73) 787.5/ 945.0/ 12.47/12.47 14.97/14.97 10/10 787.5 945.0 (47.2/47.2) (56.7/56.7) (.73/.73) lbs. 1.1 7.5 1.1 7.5 1.1 7.5 1.1 7.5 GRI Standard Bellows Pumps Overview 0119 012219 Page 7

Typical Dimensions Two Tandem Bellows Pumps Standard & BEL O JUST Models 1" Model.63 (16.0) BEL-O-JUST MODEL ONL Y 10.45 (265.43) 3.12 (79.24).25 (6.35) FLOW 7.67 (194.82) 5.28 (134.11) 5.12 (130.05) 1.00 5.00 (127.0) (25.4).06 (1.52) 8.19 (208.02) Dimensions in Inches (Dimensions in Millimeters).203 DIA. 4-MTG. HOLES 3.75 (95.25) 3.25 (82.55) 1.63 (41.40) GRI Standard Bellows Pumps Overview 0119 012219 Page 8

Three Tandem Bellows Pumps Standard & BEL O JUST Models Three tandem bellows pumps feature modular design for proportioning separate liquids. The flow rate of each bellows module is independently adjustable. Bellows modules are assembled out-of-phase for most efficient power usage. Total output of pump is limited to 3,000 ml/min. BEL O JUST THREE TANDEM MODEL Order notes: When ordering a three tandem bellows model, add one X code for valve and O-ring material selection and one T code for connector selection from the Bellows Part Selection Guide on page 16. Example: 13700-011 (1 x 1 x 1 three tandem model) with EPT/EPDM poppet valves and O-rings and elbow connectors for 3 8 I.D. tubing would be ordered as 13700-011 X-112 T-008 X-112 T-008 X-112 T-008. *Amp values for 240V will be approximately 50% of 120V values shown above. MODEL SPECIFICATIONS Standard Single BEL O JUST Discharge Maximum Flow Gallons (Liters) Bellows Strokes per minute ml per minute per hour Max. Electrical Approx. Model Number Model Number (Motor RPM) per module per module Pressure Amps* Wt. 120V/60 Hz 240V/60 Hz 120V/60 Hz 240V/60 Hz Diameter PSI 120V 110V/50 Hz 220V/50 Hz 110V/50 Hz 220V/50 Hz Inches 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz (kg/cm 2 ) 60 Hz 250.0/ 300.0/ 4.0/4.0/4.0 4.8/4.8/4.8 20/20/20 13700-011 13700-012 14252-007 14252-008 1 x 1 x 1 50 60 250.0/ 300.0/ (15.0/15.0/ (18.0/18.0/ (1.50/1.50/ 1.1 9 250.0 300.0 15.0) 18.0) 1.50) 375.0/ 450.0/ 5.9/5.9/5.9 7.1/7.1/7.1 20/20/20 13700-009 13700-010 14252-005 14252-006 1 x 1 x 1 75 90 375.0/ 450.0/ (22.5/22.5/ (27.0/27.0/ (1.50/1.50/ 1.1 9 375.0 450.0 22.5) 27.0) 1.50) 525.0/ 630.0/ 8.3/8.3/8.3 13716-012 13716-013 15905-003 15905-004 1 1 2 x 1 1 2 50 60 525.0/ 630.0/ (31.5/31.5/ x 1 1 2 525.0 630.0 31.5) 787.5/ 945.0/ 13716-009 13716-010 15905-001 15905-002 1 1 2 x 1 1 2 75 90 787.5/ 945.0/ x 1 1 2 787.5 945.0 10.0/10.0 10.0 (37.8/37.8/ 37.8) 12.5/12.5 15.0/15.0 12.5 15.0 (47.2/47.2/ (56.7/56.7/ 47.2) 56.7) lbs. 10/10/10 (.73/.73/ 1.1 9.73) 10/10/10 (.73/.73/ 1.1 9.73) GRI Standard Bellows Pumps Overview 0119 012219 Page 9

Typical Dimensions Three Tandem Bellows Pumps Standard & BEL O JUST Models 1 1 2" Model.63 (16.0) BEL-O-JUST MODEL ONL Y 13.2 (335.28) 3.12 (79.24).25 (6.35) FLOW 7.67 (194.82) 5.28 (134.11) 5.12 (130.05) 1.00 5.00 (127.0) (25.4).06 (1.52) 10.94 (277.87) 3.00 (76.2).203 DIA. 6-MTG. HOLES 3.75 (95.25) 3.25 (82.55) 1.63 (41.40) Dimensions in Inches (Dimensions in Millimeters) GRI Standard Bellows Pumps Overview 0119 012219 Page 10

Single Stroke Dispensing Bellows Pumps Actuation of the single stroke dispensing pump is triggered by a switch. The crank makes one revolution before a microswitch interrupts the power circuit. Flow rates can be adjusted. Gearmotors on dispensing pump are rated for intermittent duty cycles. 2 1 / 2 SINGLE STROKE MODEL Order notes: When ordering a single stroke model, add one X code for valve and O-ring material selection and one T code for connector selection from the Bellows Part Selection Guide on page 16. Example: 12800-007 (2½ bellows model) with EPT/EPDM poppet valves and O-rings and elbow connectors for 1 2 I.D. tubing would be ordered as 12800-007 X-122 T-009. *Amp values for 240V will be approximately 50% of 120V values shown above. MODEL SPECIFICATIONS Dispensing Pump Discharge Strokes per min. Max. Electrical Approx. Model Number Bellows Motor RPM Max. Flow Pressure Amps* Wt. ml per 120V 240V Diameter stroke PSI 120V 50/60 Hz 50/60 Hz Inches 50 Hz 60 Hz (kg/cm lbs. 2 ) 60 Hz 15090-001 15090-002 1 8.3 10 5.0 40 (2.9).3 5 15090-003 15090-004 1 1 2 8.3 10 10.5 20 (1.5).3 5 12800-007 12800-026 2 1 2 8.3 10 55.0 5 (.37).3 5 GRI Standard Bellows Pumps Overview 0119 012219 Page 11

Typical Dimensions Single Stroke Dispensing Bellows Pumps 1 1 2" Model DIMENSIONS Pump Model A B 1" - 1 1 2" 8.3 (210.8) 3.45 (87.6) 2 1 2" 7.67 (194.8) FLOW A.187 DIA. 5-MTG. HOLES 5.95 (151.13) 1.19 (30.22) 2.38 (60.45) Dimensions in Inches (Dimensions in Millimeters) 4.97 (126.24) 1.44 (36.57).34 2.19 (55.62) (8.63).37 (9.39) 2.94 (74.67) B GRI Standard Bellows Pumps Overview 0119 012219 Page 12

Heavy Duty Bellows Pumps The heavy-duty models are specially designed for use in dusty environments or for those applications requiring extremely long life. The pump is supplied with a totally enclosed gearmotor with an expected life of over 10,000 hours. The standard crank mechanism is used on heavy-duty pumps. The heavy-duty pump is recommended for 24 hour/ day continuous duty applications. 2 1 / 2 HEAVY DUTY MODEL Order notes: When ordering a heavy-duty model, add one X code for valve and O-ring material selection and one T code for connector selection from the Bellows Part Selection Guide on page 16. Example: 15955-001 (1½ bellows model) with EPT/EPDM poppet valves and O-rings and elbow connectors for 1 2 I.D. tubing would be ordered as 15955-001 X-112 T-009. Single Model Number 115V/60 Hz Bellows Discharge Strokes per minute (Motor RPM) MODEL SPECIFICATIONS Maximum Flow Gallons (Liters) Max. Electrical Approx. ml per minute per hour Pressure Amps* Wt. 240V/60 Hz Diameter PSI 115V 220V/50 Hz Inches 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz (kg/cm 2 ) 60 Hz 15955-001 15955-002 1 1 2 83 100 872 1,050 15956-001 15956-002 2 1 2 42 50 2,310 2,750 13.8 16.6 20 (52.3) (63) (1.5) 36.6 43.6 5 (138.6) (165) (.37) Ibs..6 6.6 6 GRI Standard Bellows Pumps Overview 0119 012219 Page 13

Typical Dimensions Heavy Duty Bellows Pumps 1 1 2" Model 8.61 (218.7) 3.50 (88.9).93 (23.6) FLOW 7.65 (194.3) 5.92 (150.4).250 DIA. 6-MTG. HOLES.94 (23.9) 2.50 (63.5) 1.67 (42.4) 3.06 (77.7) 1.88 (47.8) 3.75 (95.3) 4.32 (109.7) 2 1 2" Model 8.60 (218.4) FLOW 3.50 (88.9).93 (23.6) 8.11 (206.0) 5.92 (150.4) 6.45 (163.8) Dimensions in Inches (Dimensions in Millimeters).94 (23.9) 2.50 (63.5) 2.08 (52.8) 3.06 (77.7) 1.88 (47.8) 3.75 (95.3) 4.32 (109.7) GRI Standard Bellows Pumps Overview 0119 012219 Page 14

Dial-A-Flow Bellows Pumps The Dial-A-Flow pump is supplied with an adjustable speed motor. Infinite speed adjustments can be made from 3 to 60 RPM. Speed control and adjustment of stroke length can be utilized to obtain desired flow rate. The Dial-A-Flow pump uses a standard crank mechanism. 1 1 / 2 DIAL-A-FLOW MODEL Order notes: When ordering a Dial-A-Flow model, add one X code for valve and O-ring material selection and one T code for connector selection from the Bellows Part Selection Guide on page 16. Example: 15950-001 (1½ bellows model) with EPT/EPDM poppet valves and O-rings and elbow connectors for ½ I.D. tubing would be ordered as 15950-001 X-112 T-009. Single Model Number 115V/60 Hz 220V/50 Hz Bellows Discharge Strokes per minute (Motor RPM) MODEL SPECIFICATIONS Maximum Flow Gallons (Liters) Max. Electrical Approx. ml per minute per hour Pressure Amps* Wt. Diameter PSI 115V Inches 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz (kg/cm 2 ) 60 Hz 15950-001 N/A 1 1 2 50 60 525 630 8.3 10 20 (31.5) (37.8) (1.5) Ibs..85 6 GRI Standard Bellows Pumps Overview 0119 012219 Page 15

Typical Dimensions Dial-A-Flow Bellows Pumps 1 1 2" Model 9.59 (243.6) 3.50 (88.9) 1.07 (27.2) FLOW 7.65 (194.3) 5.66 (143.8) 5.26 (133.4).250 DIA. 6-MTG. HOLES.94 (23.9) 2.50 (63.5) 2.51 (63.8) 3.06 (77.7) 4.32 (109.7) 1.88 (47.8) 3.75 (95.3) Dimensions in Inches (Dimensions in Millimeters) GRI Standard Bellows Pumps Overview 0119 012219 Page 16

T-Code For Elastomeric Tubing Size T-CODES Connector Type Bellows Module Size T-001 1 8" I.D. x 1 4" O.D. Barbed Compression 1 2" T-002 1 4" I.D. x 3 8" O.D. Barbed Compression 1 2" T-003 3 8" I.D. Barbed 1", 1 1 2" & 2 1 2" T-004 1 2" I.D. Barbed 1", 1 1 2" & 2 1 2" T-005 1 8" pipe thread Female NPT 1", 1 1 2" & 2 1 2" T-006** 1 8" I.D. x 1 4" O.D. Barbed Compression 1", 1 1 2" & 2 1 2" T-007** 1 4" I.D. X 3 8" O.D. Barbed Compression 1", 1 1 2" & 2 1 2" T-008 3 8" I.D. Elbow Swivel, Barbed 1", 1 1 2" & 2 1 2" T-009 1 2" I.D. Elbow Swivel, Barbed 1", 1 1 2" & 2 1 2" T-011 1 4" I.D. Elbow Swivel, Barbed 1", 1 1 2" & 2 1 2" T-012* 4mm ( 5 32") I.D. Elbow Swivel, Barbed 1", 1 1 2" & 2 1 2" T-013* 4mm ( 5 32") I.D. Elbow Swivel, Barbed 1 2" Part Selection Guide - Bellows Metering Order notes: One T and one X code for each bellows module is required. (When ordering tandem pumps, the largest bellows module is nearest the gearmotor.) Example: 13726-014 (1½ x 1½ two tandem standard model) with EPT/EPDM poppet valves and O-rings and 3 8 elbow connectors would be ordered as a 13726-014 X-112 T-008 X-112 T-008. For flows of 1800 ml/min and above, ½ I.D. tubing connectors recommended. *Use of 4mm connector is limited by flow rate; please contact factory with specifications. **Cost added for connector. T-014 1 4" I.D. Barbed 1", 1 1 2" & 2 1 2" T-001 T-002 T-003 T-004 T-005 T-006 T-007 T-008 T-009 Poppet Valves and O-Rings (X-codes) Materials X-CODES 1 2" 1" & 1 1 2" 2 1 2" Bellows Bellows Bellows Butyl X-111 X-121 *EPT/EPDM X-002 X-112 X-122 Hydrin X-003 X-113 X-123 *Viton / Fluoroelastomer X-006 X-116 X-126 Silicone X-008 X-118 X-128 Nitrile X-119 X-129 *Indicates stocked elastomer. **Cost added for material. Duckbill Valves and O-Rings (X-codes) Materials X-CODES 1 2" 1" & 1 1 2" 2 1 2" Bellows Bellows Bellows Butyl X-091 X-031 X-041 *EPT/EPDM X-092 X-032 X-042 Hydrin X-093 X-033 X-043 044 **Viton / Fluoroelastomer X-096 X-036 X-046 Silicone X-098 X-038 X-048 Nitrile X-099 X-039 X-049 *Indicates stocked elastomer. **Cost added for material. 1 2" Poppet Kit 1 2" Bellows Kit T-011 T-012 T-013 T-014 1", 1 1 2" and 2 1 2" Poppet Kit 1", 1 1 2" and 2 1 2" Bellows Kit (Valve extension required only on suction port.) GRI Standard Bellows Pumps Overview 0119 012219 Page 17

Options Bellows Metering GRI specializes in the adaptation of standard models to meet the ever-changing needs of the Original Equipment Market. Contact us if one of our standard models does not meet your specific requirements. Motors Speeds Standard motor speeds are 39, 60, 90 and 165 RPM at 60 Hz. Gearmotors can be supplied in virtually any speed up to 165 RPM. Voltages Standard voltages are 115V, 50/60 Hz or 230V, 50/60 Hz. However, the following special voltages are also available: 12 and 24 VDC. Designs The standard motor is an open, shaded pole gearmotor. Motors are also available with brakes. Options Units without motors (pedestal models) are available on some models. PEDESTAL MODEL Valve Bodies Standard valve body on the bellows pump is a 90 valve body. Vertical and T-head valve bodies can be substituted on all bellows sizes except the 1 2" bellows. Poppet Valve Standard poppet valve materials are available. Polypropylene material can be substituted. Pump Cover Bellows pumps are available with or without a stainless steel cover, front shield, on/off switch, and cord and plug. Mounting brackets are also available with epoxy-coated rolled steel. However, a minimum quantity purchase is required. GRI Standard Bellows Pumps Overview 0119 012219 Page 18

Accessories Bellows Metering Check and Foot Valves Check and foot valves are used to maintain a pump s prime or to prevent backflow through a pump in applications with long suction lengths. Check valves can be positioned in-line on the suction or discharge side of the pump; foot valves on the suction side only. To order, refer to the chart on this page. Elastomer Single Check Valves Dual Check Valves Foot Valves 3 8" I.D. 1 2" I.D. 3 8" I.D. 3 8" I.D. 1 2" I.D. Tubing Tubing Tubing Tubing Tubing EPT/EPDM 15099-002 15099-018 12171-004 15101-002 15101-018 Viton / Fluoro- 15099-006 15099-022 15101-006 15101-022 elastomer Single Check Valve Opening Pressure: 1 psi (spring loaded) Materials in Contact with Solution: Body, valve seat, connectors, screen (149 Micron) - Polypropylene O-rings - EPT/EPDM, Viton /Fluoroelastomer Spring - Hastelloy C Options: 1 2 or 3 8 I.D. tubing connectors Dual Check Valve Opening Pressure:.2 psi (two poppets located in series) Materials in Contact with Solution: Body, connectors - Polypropylene Poppet valves & O-rings EPT/EPDM Foot Valve Opening Pressure: 1 psi (spring loaded) Materials in Contact with Solution: Body, valve seat, connectors, screen (149 Micron) - Polypropylene O-rings - EPT/EPDM, Viton /Fluoroelastomer Spring - Hastelloy C Options: 1 2 or 3 8 I.D. tubing connectors Anti-Siphon Spring Kits Anti-siphon springs are available to springload poppet valves. Use of these springs produces more positive shutoff of poppet valves and permits use of the pump where there is a positive pressure on the suction side. Available for the 1", 1½" and 2½" models. To order, select the proper spring material and O-ring by referring to the Chemical Resistance Section. The appropriate kit can then be chosen based on the blow-off pressure (PSI) required. (Valve extension required only on suction port.) O-Ring (Elastomer) Material Spring EPT/EPDM Viton /Fluoroelastomer.5 PSI 5 PSI.5 PSI 5 PSI Monel 02501-112 02501-113 02501-124 02501-525 316 S.S. 02501-114 02501-115 02501-126 02501-127 Hastelloy C 02501-116 02501-117 02501-128 02501-129 Kits include valve extension for suction port. Kits do not include poppet valve. GRI Standard Bellows Pumps Overview 0119 012219 Page 19

Replacement Kits Bellows Metering Bellows Module Kits Bellows module kits include connecting rod assembly, bellows module, displacement cup, screws and O-rings. 2 1 /2" Standard Kit 2 1 /2" BEL O JUST Kit 1 1 /2" Standard Kit 1 /2" BEL O JUST Kit Crank Kits Standard crank kit includes lock nut, flat washer and crank assembly. BEL O JUST crank kit includes rod bushing, bearing, bearing bushing, drive arm, set screw, bushing, crank, control arm and retaining ring. Standard Crank Kit BEL O JUST Crank Kit Motor Kit Motor kit includes motor, fan, mounting screws, felt pad and ground screw. Motor Kit Ordering Kits To order, refer to Replacement Kit charts on following pages. GRI Standard Bellows Pumps Overview 0119 012219 Page 20

SINGLE BELLOWS METERING PUMPS REPLACEMENT KITS Bellows Module Replacement Kits Crank Assembly Motor Model Replacement Kits Replacement Number Butyl EPT/EPDM Hydrin Hypalon Kel-F Viton /Fluoro- Silicone Nitrile Inner Outer Kits elastomer Module Module 12800-007 02500-984 02500-649 02500-985 02500-460 02500-651 02500-652 02500-653 02500-986 02501-092 02501-091 12800-026 02500-984 02500-649 02500-985 02500-460 02500-651 02500-652 02500-653 02500-986 02501-092 02501-090 12950-003 02500-376 02500-284 02500-375 02500-237 02500-374 02500-373 02500-372 02500-371 02500-853 02500-996 12950-004 02500-376 02500-284 02500-375 02500-237 02500-374 02500-373 02500-372 02500-371 02500-853 02501-003 13300-007 02500-388 02500-274 02500-387 02500-262 02500-386 02500-385 02500-384 02500-383 02500-852 02500-996 13300-008 02500-388 02500-274 02500-387 02500-262 02500-386 02500-385 02500-384 02500-383 02500-852 02501-003 13300-009 02500-388 02500-274 02500-387 02500-262 02500-386 02500-385 02500-384 02500-383 02500-852 02500-995 13300-010 02500-388 02500-274 02500-387 02500-262 02500-386 02500-385 02500-384 02500-383 02500-852 02501-004 13300-045 02500-388 02500-274 02500-387 02500-262 02500-386 02500-385 02500-384 02500-383 02500-852 02500-999 13300-046 02500-388 02500-274 02500-387 02500-262 02500-386 02500-385 02500-384 02500-383 02500-852 02501-005 13300-047 02500-388 02500-274 02500-387 02500-262 02500-386 02500-385 02500-384 02500-383 02500-852 02501-000 13300-048 02500-388 02500-274 02500-387 02500-262 02500-386 02500-385 02500-384 02500-383 02500-852 02501-006 13325-001 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02500-996 13325-002 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02501-003 13325-003 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02500-995 13325-004 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02501-004 13325-005 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02500-999 13325-006 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02501-005 13325-031 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02501-000 13325-032 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02501-006 13960-022 02500-393 02500-315 02500-392 02500-313 02500-391 02500-314 02500-390 02500-389 02500-851 02500-996 13960-024 02500-393 02500-315 02500-392 02500-313 02500-391 02500-314 02500-390 02500-389 02500-851 02501-003 13960-027 02500-393 02500-315 02500-392 02500-313 02500-391 02500-314 02500-390 02500-389 02500-851 02501-000 13960-028 02500-393 02500-315 02500-392 02500-313 02500-391 02500-314 02500-390 02500-389 02500-851 02501-006 14250-005 02500-428 02500-429 02500-430 02500-427 02500-431 02500-432 02500-433 02500-434 02501-033 02500-996 14250-006 02500-428 02500-429 02500-430 02500-427 02500-431 02500-432 02500-433 02500-434 02501-033 02501-003 14250-007 02500-428 02500-429 02500-430 02500-427 02500-431 02500-432 02500-433 02500-434 02501-033 02500-995 14250-008 02500-428 02500-429 02500-430 02500-427 02500-431 02500-432 02500-433 02500-434 02501-033 02501-004 14250-014 02500-428 02500-429 02500-430 02500-427 02500-431 02500-432 02500-433 02500-434 02501-033 02500-999 14250-015 02500-428 02500-429 02500-430 02500-427 02500-431 02500-432 02500-433 02500-434 02501-033 02501-005 14250-016 02500-428 02500-429 02500-430 02500-427 02500-431 02500-432 02500-433 02500-434 02501-033 02501-000 14250-017 02500-428 02500-429 02500-430 02500-427 02500-431 02500-432 02500-433 02500-434 02501-033 02501-006 14251-001 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-033 02500-996 14251-002 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-033 02501-003 14251-003 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-033 02500-995 14251-004 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-033 02501-004 14251-005 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-033 02500-999 14251-006 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-033 02501-005 14251-007 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-033 02501-000 14251-008 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-033 02501-006 14280-006 02500-420 02500-421 02500-422 02500-445 02500-423 02500-424 02500-425 02500-426 02501-035 02500-996 14280-007 02500-420 02500-421 02500-422 02500-445 02500-423 02500-424 02500-425 02500-426 02501-035 02501-003 14280-009 02500-420 02500-421 02500-422 02500-445 02500-423 02500-424 02500-425 02500-426 02501-035 02501-000 14280-014 02500-420 02500-421 02500-422 02500-445 02500-423 02500-424 02500-425 02500-426 02501-035 02501-006 14282-001 02500-428 02500-429 02500-430 02500-427 02500-431 02500-432 02500-433 02500-434 02501-033 14291-001 02500-388 02500-274 02500-387 02500-262 02500-386 02500-385 02500-384 02500-383 02500-852 15076-003 02500-627 02500-628 02500-629 02500-631 02500-630 02500-632 02500-633 02500-634 02501-033 02500-999 15076-004 02500-627 02500-628 02500-629 02500-631 02500-630 02500-632 02500-633 02500-634 02501-033 02501-005 15090-001 02500-969 02501-647 02500-971 02500-968 02500-972 02500-973 02500-974 02500-967 02501-093 02501-091 15090-002 02500-969 02501-647 02500-971 02500-968 02500-972 02500-973 02500-974 02500-967 02501-093 02501-090 15090-003 02500-960 02501-646 02500-962 02500-886 02500-966 02500-965 02500-963 02500-964 02501-093 02501-091 15090-004 02500-960 02501-646 02500-962 02500-886 02500-966 02500-965 02500-963 02500-964 02501-093 02501-090 GRI Standard Bellows Pumps Overview 0119 012219 Page 21

SINGLE BELLOWS METERING PUMPS REPLACEMENT KITS (continued) Crank Assembly Bellows Module Replacement Kits Motor Model Replacement Kits Replacement Number Butyl EPT/EPDM Hydrin Hypalon Kel-F /Fluoro- Inner Outer Kits Viton elastomer Silicone Nitrile Module Module 15950-001 02501-255 02501-256 02501-257 02500-852 15955-001 02501-255 02501-256 02501-257 02500-852 15955-002 02501-255 02501-256 02501-257 02500-852 15956-001 02501-323 02501-229 02501-324 02500-879 15956-002 02501-323 02501-229 02501-324 02500-879 SIDE-BY-SIDE BELLOWS PUMPS REPLACEMENT KITS 13191-043 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02501-027 13191-044 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-852 02501-031 13193-001 02500-376 02500-284 02500-375 02500-237 02500-374 02500-373 02500-372 02500-371 02500-853 02501-027 13193-002 02500-376 02500-284 02500-375 02500-237 02500-374 02500-373 02500-372 02500-371 02500-853 02501-031 TWO TANDEM BELLOWS PUMPS REPLACEMENT KITS 13701-019 02500-274 02500-262 02500-385 02500-855 02500-852 02500-999 13701-020 02500-274 02500-262 02500-385 02500-855 02500-852 02501-005 13701-021 02500-274 02500-262 02500-385 02500-855 02500-852 02500-995 13701-022 02500-274 02500-262 02500-385 02500-855 02500-852 02501-004 13726-014 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-855 02500-852 02500-999 13726-015 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-855 02500-852 02501-005 13726-016 02500-279 02500-263 02500-379 02500-855 02500-852 02500-995 13726-017 02500-279 02500-263 02500-379 02500-855 02500-852 02501-004 14324-027 02500-429 02500-427 02500-432 02501-034 02501-033 02500-999 14324-028 02500-429 02500-427 02500-432 02501-034 02501-033 02501-005 14324-029 02500-429 02500-427 02500-432 02501-034 02501-033 02500-995 14324-030 02500-429 02500-427 02500-432 02501-034 02501-033 02501-004 15904-001 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-034 02501-033 02500-999 15904-002 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-034 02501-033 02501-005 15904-003 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-034 02501-033 02500-995 15904-004 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-034 02501-033 02501-004 THREE TANDEM BELLOWS PUMPS REPLACEMENT KITS 13700-009 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-855 02500-852 02500-999 13700-010 02500-279 02500-263 02500-379 02500-855 02500-852 02501-005 13700-011 02500-279 02500-263 02500-379 02500-855 02500-852 02500-995 13700-012 02500-279 02500-263 02500-379 02500-855 02500-852 02501-004 13716-009 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-855 02500-852 02500-999 13716-010 02500-382 02500-279 02500-381 02500-263 02500-380 02500-379 02500-378 02500-377 02500-855 02500-852 02501-005 13716-012 02500-279 02500-263 02500-379 02500-855 02500-852 02500-995 13716-013 02500-279 02500-263 02500-379 02500-855 02500-852 02501-004 14252-005 02500-429 02500-427 02500-432 02501-034 02501-033 02500-999 14252-006 02500-429 02500-427 02500-432 02501-034 02501-033 02501-005 14252-007 02500-429 02500-427 02500-432 02501-034 02501-033 02500-995 14252-008 02500-429 02500-427 02500-432 02501-034 02501-033 02501-004 15905-001 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-034 02501-033 02500-999 15905-002 02500-436 02500-437 02500-438 02500-435 02500-439 02500-440 02500-441 02500-442 02501-034 02501-033 02501-005 15905-003 02500-437 02500-427 02500-440 02501-034 02501-033 02500-995 15905-004 02500-437 02500-427 02500-440 02501-034 02501-033 02501-004 GRI Standard Bellows Pumps Overview 0119 012219 Page 22

Replacement Kits Bellows Metering Poppet Valve Kit Poppet valve kit includes two poppet valves and two O-rings. Bellows Size 1 2" 1" 1 1 2" 2 1 2" POPPET VALVE AND O-RING KITS Materials Butyl EPT/EPDM Hydrin Hypalon Kel-F Viton /Fluoroelastomer Silicone 02500-318 02500-348 02500-316 02500-349 02500-317 02500-350 (X-002) (X-003) (X-005) (X-004) (X-006) (X-008) Nitrile 02500-604 02500-605 02500-606 02500-608 02500-607 02500-609 02500-610 02500-611 (X-111) (X-112) (X-113) (X-115) (X-114) (X-116) (X-118) (X-119) 02500-604 02500-605 02500-606 02500-608 02500-607 02500-609 02500-610 02500-611 (X-111) (X-112) (X-113) (X-115) (X-114) (X-116) (X-118) (X-119) 02500-604 02500-605 02500-606 02500-608 02500-607 02500-609 02501-486 02500-611 (X-121) (X-122) (X-123) (X-125) (X-124) (X-126) (X-128) (X-129) Duckbill Valve Kit Duckbill valve kit includes two duckbill valves, two seal washers, one valve extension and one O-ring. DUCKBILL VALVE AND O-RING KITS Bellows Size 1 2" 1" 1 1 2" 2 1 2" Materials Butyl EPT/EPDM Hydrin Hypalon Kel-F Viton /Fluoroelastomer Silicone Nitrile 02500-596 (X-091) 02500-597 (X-092) 02500-600 (X-095) 02500-599 (X-094) 02500-601 (X-096) 02500-327 (X-031) 02500-322 (X-032) 02501-528 (X-033) 02500-325 (X-035) 02500-355 (X-034) 02500-319 (X-036) 02500-324 (X-038) 02500-320 (X-039) 02500-327 (X-031) 02500-322 (X-032) 02501-528 (X-033) 02500-325 (X-035) 02500-355 (X-034) 02500-319 (X-036) 02500-324 (X-038) 02500-320 (X-039) 02500-327 (X-041) 02500-322 (X-042) 02501-528 (X-043) 02500-325 (X-045) 02500-355 (X-044) 02500-319 (X-046) 02500-324 (X-048) 02500-320 (X-049) TUBING CONNECTOR KITS T-Code Kit Part Number T-001 02500-312 T-002 02500-635 T-003 02500-352 T-004 02500-353 T-005 02500-258 T-006 02500-259 T-007 02500-260 T-008 02500-261 T-009 02500-354 T-011 02501-337 T-012 02501-246 T-013 02501-541 T-014 02501-673 Tubing Connector Kit Tubing connector kit includes two connectors and two connector nuts. GRI Standard Bellows Pumps Overview 0119 012219 Page 23