Lenovo RackSwitch G8272. Release Notes. For Networking OS 8.2

Similar documents
Lenovo Flex System SI Gb System Interconnect Module. Release Notes. for Networking OS 8.2

Lenovo RackSwitch G8272. Release Notes. For Cloud Network Operating System 10.3

Lenovo RackSwitch G8272. Release Notes. For Cloud Network Operating System 10.2

Lenovo RackSwitch G8052. Release Notes. For Enterprise Network Operating System 8.4

Lenovo ThinkSystem NE1032/NE1032T/NE1072T. Release Notes. For Lenovo Cloud Network Operating System 10.6

IBM System Networking RackSwitch G8332. Release Notes. For Networking OS 7.7

Lenovo RackSwitch G8272. Release Notes. For Lenovo Cloud Network Operating System 10.7

Lenovo ThinkSystem NE Release Notes. For Lenovo Cloud Network Operating System 10.7

Lenovo ThinkSystem NE1032/NE1032T/NE1072T RackSwitch. Release Notes. For Lenovo Cloud Network Operating System 10.8

Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch. Release Notes. for Networking OS 8.2

Lenovo ThinkSystem NE Release Notes. For Lenovo Cloud Network Operating System 10.6

Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch. Release Notes. for Lenovo Network OS 8.4

IBM System Networking RackSwitch G8124/G8124-E. Release Notes. For IBM Networking OS 7.11

IBM System Networking RackSwitch G8264. Release Notes. For IBM Networking OS 7.11

Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch. Release Notes. for Networking OS 8.3

EX2500 Ethernet Switch 3.1 Release Notes

S38 Basic Configuration

Assigning the Switch IP Address and Default Gateway

Upgrading the Software

CCNA 1 Chapter 2 v5.0 Exam Answers %

EX2500 Ethernet Switch 3.0 Release Notes

IBM Networking OS 7.5. Release Notes. for the EN2092 1Gb Ethernet Scalable Switch, Second Edition (replaces 88Y7950)

Management Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev.

Configure Dynamic Host Configuration Protocol (DHCP) Image Upgrade Settings on a Switch through the Command Line Interface (CLI)

CCNA 1 Chapter 2 v5.0 Exam Answers 2013

ROM Monitor. Using ROM Monitor APPENDIX

CHAPTER 2 ACTIVITY

Lenovo NE1032 and NE1032T Switch

Configurations for the Layer 3 Switch Router

D-Link (Europe) Ltd. 4 th Floor Merit House Edgware Road London HA7 1DP U.K. Tel: Fax:

EasyIO 30P Firmware Flashing and Upgrading. Firmware Flashing and Upgrading

Cisco 4000 Series Virtual Configuration Register

Cisco Branch Routers Series Network Analysis Module (NME-NAM-120S) Installation and Configuration Note, 4.2

RELEASE NOTES: Web OS Great America Parkway Santa Clara, CA Phone Nortel

Table of Contents. Cisco Password Recovery Procedure for the Cisco Aironet Equipment

Reimage Procedures. Firepower 2100 Series Software Reimage and Disaster Recovery

No Service Password-Recovery

Lab 6.2.7a Managing Switch Operating System Files

SSL VPN Reinstallation

Configuring Host Router and Cisco Analog Video Gateway Module Interfaces

16/24/48-Port 10/100/1000T + 2/4-Port 100/1000X SFP Managed Switch GS T2S/GS T2S/GS T4S. Quick Installation Guide

Lenovo Storage DX8200D System Installation Guide (Additional Appliances in Existing Server Group)

Maintaining the MGX RPM-PR

Configuring for the First Time

Using the Cisco NX-OS Setup Utility

Assigning the Switch IP Address and Default Gateway

L2+ Managed LCD Switch GS T2XV(R) / GS T4XV(R) Quick Installation Guide

UPGRADING THE ARCTIC FIRMWARE

Command-Line Interfaces

**Note that this must be run from a PC on the same network segment as the NetBotz device, and the NetBotz device MUST be connected to the network.

Deployment of a new M-Lab site

File Transfers. Contents

Maintaining the System Software

MiPDF.COM. 3. Which procedure is used to access a Cisco 2960 switch when performing an initial configuration in a secure environment?

Nortel Secure Router 2330/4134 Commissioning. Release: 10.2 Document Revision: NN

L2+ Managed Gigabit Switch WGSW series

Assigning the Switch IP Address and Default Gateway

Upgrade 6081RC Firmware

Lab Add, Move, and Change MAC Addresses

Switched Rack Power Distribution Unit

Lenovo ThinkAgile XClarity Integrator for Nutanix Installation and User's Guide

Using the Cisco NX-OS Setup Utility

Initial Configuration for the Switch

Lab Password Recovery Procedure on a Catalyst 2900 Series Switches

48-Port 10/100/1000Base-T with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Dr. Tom Hicks. Computer Science Department Trinity University

Troubleshooting Initial Startup Problems

Chapter 4. Network Security. Part II

DGS-3630-Series Switches

16/24-Port 10/100/1000T 802.3at PoE + 2-Port 100/1000X SFP Managed Switch GS P2S GS P2S. Quick Installation Guide

Working with Configuration Files

Table of Contents. Cisco Password Recovery Procedure for the Cisco Aironet Equipment

Assigning the Switch IP Address and Default Gateway

Managing Services Modules

Bring-up the Router. Boot the Router

Lab Password Recovery Procedure on a Catalyst 2950 Series Switch 2900XL Series

Lab Using the Boot System Command. Objective. Background/Preparation

L2/L4 Managed Gigabit Ethernet Switch GS-4210 Ultra PoE Series

Password Recovery Procedure for the Password Recovery Procedure for Cisco Aironet Equipment

28-Port 10/100/1000Mbps with. 4 Shared SFP Managed Gigabit Switch WGSW / WGSW-28040P. Quick Installation Guide

Lab 7 Configuring Basic Router Settings with IOS CLI

Lab Configuring Static VLANs

Managing Software. Upgrading the Controller Software. Considerations for Upgrading Controller Software

Initial Configuration

Controlling Switch Access with Passwords and Privilege Levels

Management Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev.

Industrial 24-Port 10/100/1000Mbps Managed Gigabit. Switch (-40~75 degrees C) with 4 Shared SFP Ports IGSW-24040T. Quick Installation Guide

Configuration Guide. Upgrading AOS Firmware L1-29.1D July 2011

UPGRADING ARCTIC CONTROL S FIRMWARE

L2+ Managed Gigabit/10 Gigabit Ethernet Switch GS-5220 Series

When an event such as a power failure or a low battery condition occurs,.netpower will notify users via the following ways:

INSTRUCTIONS TO UPDATE FIRMWARE FOR

Network Drawing. Computer Specs, I ve used. Installing a Network-Based Intrusion Detection

First Steps. esom/sk4 esom/3517 Embedded Linux Starter Kit

ideacentre 610S Quick Start Guide

Barracuda NG Firewall F400 Revision B

Xinu on Intel Galileo User Manual

Troubleshooting. Diagnosing Problems CHAPTER

Controlling Switch Access with Passwords and Privilege Levels

2.1. Device Connection

Transcription:

Lenovo RackSwitch G8272 Release Notes For Networking OS 8.2

Note: Before using this information and the product it supports, read the general information in the Safety information and Environmental Notices and User Guide documents on the Lenovo Documentation CD and the Warranty Information document that comes with the product. First Edition (April 2015) Copyright Lenovo 2015 Portions Copyright IBM Corporation 2014. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant a General Services Administration GSA contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-35F-05925. Lenovo and the Lenovo logo are trademarks of Lenovo in the United States, other countries, or both.

Release Notes This release supplement provides the latest information regarding Lenovo Networking OS 8.2 for the Lenovo RackSwitch G8272 (referred to as G8272 throughout this document). This supplement modifies and extends the following Lenovo N/OS documentation for use with N/OS 8.2: Lenovo Networking OS 8.2 Application Guide Lenovo Networking OS 8.2 ISCLI Reference Lenovo RackSwitch G8272 Installation Guide The publications listed above are available from the following website: http://publib.boulder.ibm.com/infocenter/systemx/documentation/index.jsp Please keep these release notes with your product manuals. Copyright Lenovo 2015 Release Notes 3

Hardware Support N/OS 8.2 software is supported on the G8272, a high performance Layer 2-3 network switch. The G8272 is a 1U rack-mountable aggregation switch with unmatched line-rate Layer 2 performance. The G8272 uses a wire-speed, non-blocking switching fabric that provides simultaneous wire-speed transport of multiple packets at low latency on all ports. The switch unit contains the following switching ports: Forty-eight 10 Gigabit Ethernet (GbE) Small Form Pluggable Plus (SFP+) ports which also support legacy 1 GbE connections Six 40 GbE Quad Small Form Pluggable Plus (QSFP+) ports, each of which can optionally be used as four 10 GbE SFP+ ports Figure 1. RackSwitch G8272 front panel 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 Management Panel SFP+ Ports QSFP+ Ports 4 Lenovo G8272: Release Notes

Updating the Switch Software Image The switch software image is the executable code running on the G8272. A version of the image comes pre-installed on the device. As new versions of the image are released, you can upgrade the software running on your switch. To get the latest version of software supported for your G8272, go to the following website: http://www.ibm.com/support To determine the software version currently used on the switch, use the following switch command: The typical upgrade process for the software image consists of the following steps: Load a new software image and boot image onto an SFTP, FTP, or TFTP server on your network. Transfer the new images to your switch. Specify the new software image as the one which will be loaded into switch memory the next time a switch reset occurs. Reset the switch. For instructions on the typical upgrade process, see Loading New Software to Your Switch on page 5. Loading New Software to Your Switch The G8272 can store up to two different switch software images (called image1 and image2) as well as special boot software (called boot). When you load new software, you must specify where it should be placed: either into image1, image2, or boot. For example, if your active image is currently loaded into image1, you would probably load the new image software into image2. This lets you test the new software and reload the original active image (stored in image1), if needed. Attention: When you upgrade the switch software image, always load the new boot image and the new software image before you reset the switch. If you do not load a new boot image, your switch might not boot properly (To recover, see Recovering from a Failed Software Upgrade on page 7). To load a new software image to your switch, you will need the following: The image and boot software loaded on an SFTPFTP or TFTP server on your network. Note: Be sure to download both the new boot file and the new image file. The hostname or IP address of the SFTP, FTP, or TFTP server Note: The DNS parameters must be configured if specifying hostnames. The name of the new software image or boot file When the software requirements are met, use the following procedures to download the new software to your switch. Copyright Lenovo 2015 Release Notes 5

1. In Privileged EXEC mode, enter the following command: RS 8272(config)# copy {sftp tftp ftp} {image1 image2 boot image} 2. Enter the hostname or IP address of the SFTP, FTP, or TFTP server. Address or name of remote host: <name or IP address> 3. Enter the name of the new software file on the server. Source file name: <filename> The exact form of the name will vary by server. However, the file location is normally relative to the SFTP, FTP, or TFTP directory (for example, tftpboot). 4. If required by the SFTP, FTP, or TFTP server, enter the appropriate username and password. 5. The switch will prompt you to confirm your request. Once confirmed, the software will begin loading into the switch. 6. When loading is complete, use the following commands to enter Global Configuration mode to select which software image (image1 or image2) you want to run in switch memory for the next reboot: RS 8272# configure terminal RS 8272(config)# boot image {image1 image2} The system will then verify which image is set to be loaded at the next reset: Next boot will use switch software image1 instead of image2. 7. Reboot the switch to run the new software: RS 8272(config)# reload The system prompts you to confirm your request. Once confirmed, the switch will reboot to use the new software. Note: If you select No when asked to confirm the reload, any changes made to the configuration since the last reboot will be lost. 6 Lenovo G8272: Release Notes

Supplemental Information The Boot Management Menu This section provides additional information about configuring and operating the G8272 and N/OS. The Boot Management menu allows you to switch the software image, reset the switch to factory defaults, or to recover from a failed software download. You can interrupt the boot process and enter the Boot Management menu from the serial console port. When the system displays Memory Test, press <Shift B>. The Boot Management menu appears. Resetting at 10:55:49 Sun Apr 19, 2015 Memory Test... Boot Management Menu I Change booting image C Change configuration block R Boot in recovery mode (tftp and xmodem download of images to recover switch) Q Reboot E Exit Please choose your menu option: I Current boot image is 1. Enter image to boot: 1 or 2: 2 Booting from image 2 The Boot Management menu allows you to perform the following actions: To change the booting image, press I and follow the screen prompts. To change the configuration block, press C, and follow the screen prompts. To perform a TFTP/Xmodem download, press R and follow the screen prompts. To reboot the switch, press Q. The booting process restarts To exit the Boot Management menu, press E. The booting process continues. Recovering from a Failed Software Upgrade Use the following procedure to recover from a failed software upgrade. 1. Connect a PC to the serial port of the switch. 2. Open a terminal emulator program that supports XModem Download (for example, HyperTerminal, SecureCRT, PuTTY) and select the following serial port characteristics: Speed: Data Bits: 8 Stop Bits: 1 9600 bps Parity: Flow Control: None None Copyright Lenovo 2015 Release Notes 7

3. To access the Boot Management menu, you must interrupt the boot process from the Console port. Boot the G8272, and when the system begins displaying Memory Test progress (a series of dots), press <Shift B>. The Boot Management menu will display: Resetting at 10:55:49 Sun Apr 19, 2015 Memory Test... Boot Management Menu I Change booting image C Change configuration block R Boot in recovery mode (tftp and xmodem download of images to recover switch) Q Reboot E Exit Please choose your menu option: 4. Select R for Boot in recovery mode. You will see the following display: Entering Rescue Mode. Please select one of the following options: T) Configure networking and tftp download an image X) Use xmodem 1K to serial download an image P) Physical presence (low security mode) F) Filesystem check R) Reboot E) Exit Option?: If you choose option X (Xmodem serial download), go to step 5. If you choose option T (TFTP download), go to step 6. 8 Lenovo G8272: Release Notes

5. Xmodem download: When you see the following message, change the Serial Port characteristics to 115200 bps: Change the baud rate to 115200 bps and hit the <ENTER> key before initiating the download. a. Press <Enter> to set the system into download accept mode. When the readiness meter displays (a series of C characters), start XModem on your terminal emulator. b. When you see the following message, change the Serial Port characteristics to 9600 bps: Change the baud rate back to 9600 bps, hit the <ESC> key. c. When you see the following prompt, enter the image number where you want to install the new software and press <Enter>. Install image as image 1 or 2 (hit return to just boot image): 1 d. The following message is displayed when the image download is complete. Continue to step 7. Entering Rescue Mode. Please select one of the following options: T) Configure networking and tftp download an image X) Use xmodem 1K to serial download an image P) Physical presence (low security mode) F) Filesystem check R) Reboot E) Exit Option?: Copyright Lenovo 2015 Release Notes 9

6. TFTP download: The switch prompts you to enter the following information: Performing TFTP rescue. Please answer the following questions (enter 'q' to quit): IP addr : Server addr: Netmask : Gateway : Image Filename: a. Enter the required information and press <Enter>. b. You will see a display similar to the following: Host IP : 10.10.98.110 Server IP : 10.10.98.100 Netmask : 255.255.255.0 Broadcast : 10.10.98.255 Gateway : 10.10.98.254 Installing image G8272 8.2.1.0_OS.img from TFTP server 10.10.98.100 c. When you see the following prompt, enter the image number where you want to install the new software and press <Enter>. Install image as image 1 or 2 (hit return to just boot image): 1 d. The following message is displayed when the image download is complete. Continue to step 7. Entering Rescue Mode. Please select one of the following options: T) Configure networking and tftp download an image X) Use xmodem 1K to serial download an image P) Physical presence (low security mode) F) Filesystem check R) Reboot E) Exit Option?: 7. Image recovery is complete. Perform one of the following steps: Press r to reboot the switch. Press e to exit the Boot Management menu Press the Escape key (<Esc>) to re-display the Boot Management menu. 10 Lenovo G8272: Release Notes

Recovering from a Failed Boot Image Upgrade Use the following procedure to recover from a failed boot image upgrade. 1. Connect a PC to the serial port of the switch. 2. Open a terminal emulator program that supports Xmodem download (such as HyperTerminal, CRT, or PuTTY) and select the following serial port characteristics: Speed: 9600 bps Data Bits: 8 Stop Bits: 1 Parity: None Flow Control: None 3. Boot the switch and access the Boot Management menu by pressing <Shift B> while the Memory Test is in progress and the dots are being displayed. 4. Select R to boot in recovery mode. Then choose option X (Xmodem serial download). You will see the following display: Perform xmodem download To download an image use 1K Xmodem at 115200 bps. 5. When you see the following message, change the Serial Port characteristics to 115200 bps: Change the baud rate to 115200 bps and hit the <ENTER> key before initiating the download. a. Press <Enter> to set the system into download accept mode. When the readiness meter displays (a series of C characters), start Xmodem on your terminal emulator.you will see a display similar to the following: Extracting images... Do *NOT* power cycle the switch. **** RAMDISK **** Un Protected 38 sectors Erasing Flash...... done Erased 38 sectors Writing to Flash...9...8...7...6...5...4...3...2...1...done Protected 38 sectors **** KERNEL **** Un Protected 24 sectors Erasing Flash...... done Erased 24 sectors Writing to Flash...9...8...7...6...5...4...3...2...1... b. When you see the following message, change the Serial Port characteristics to 9600 bps: Change the baud rate back to 9600 bps, hit the <ESC> key. Copyright Lenovo 2015 Release Notes 11

12 Lenovo G8272: Release Notes Boot image recovery is complete.

Known Issues This section describes known issues for N/OS 8.2 on the RackSwitch G8272. Note: Please review the Change History documentation posted with the Switch Firmware to check if any of these issues have been fixed in the latest release. FCoE: Configuration Download FCF Error When you download a configuration file with more than 12 Fibre Channel Forwarder VLANs that differ from those in the running configuration, a configdownload:fcf error occurs. (ID: LV304109) FCoE: Only 2048 Maximum Logins Allowed When Area Size is Set to 4096 When the area size is set to 4096, maximum number of logins allowed per switch across all VLANs remains at 2048, and the maximum number of logins allowed in a VLAN remains at 2048. (ID: LV300846) Python Throws Error When Checking Help Modules A python exception is thrown when checking help ( modules ) in the switch python shell. The supported modules are those from the python 2.6.8 distribution except for bsddb, curses, idlelib, lib-tk, and xml. (ID: LV299048, LV299106). QBG: Changed STG for a Dynamically-Created VLAN Appears shutdown If a VLAN is created statically and set to disabled using the VLAN configuration command: RS 8272(config-vlan)# shutdown this will not influence QBG behavior on that VLAN. The user configuration is kept in the running configuration. (ID: XB295275) VLAG: Disconnecting ISL Ports Causes Loss in Traffic Traffic is lost when you disconnect and reconnect the ISL ports in a VLAG setup with Routing Information Protocol (RIP). Upon reconnection, the Content Addressable Memory (CAM) table does not synchronize. (ID: LV302019) Copyright Lenovo 2015 Release Notes 13

14 Lenovo G8272: Release Notes