CC240RF COMPUTE-A-CHARGE

Similar documents
Economy Charging Scale

Model SRV945-BT 24 X 36 Platform Scale App-Enabled Operating and Service Manual Part No.: MAN945-BT_ Page 1 of 16.

NIDEC-SHIMPO INSTRUMENTS

Series FGE-XY Force Gauges Operation Manual

NIDEC-SHIMPO INSTRUMENTS

User s Manual. Digital Baby Scales. Hopkins Featherweight Baby Scale # Hopkins Featherweight XL Baby Scale # # #688340

PLATINUM PRO1001V DIGITAL COUNTERTOP / PORTABLE BALANCE

Platinum RTD Thermometer MODEL NO

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

DIGITAL SOUND LEVEL METER. Instruction Manual

IVC-222HPII Precision Voltage/Current Calibrator

MODEL PS-11 DIGITAL PORTION SCALE

Platinum RTD Thermometer MODEL NO

HI HI N HI HI

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

IDS-801 Series Compact Bench Counting Scale. User Manual

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

MODEL TI-700. Digital Weight Indicator (with wireless weighing capability) User Manual

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Division Services. Model: DPAS-300. Division Portable Bulk Load Accumulator Scale INDUSTRIAL PH (901) FAX (901)

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

1.0 Description. 2.0 Unpacking. 3.0 Installation

Simple Weighing Scale. SW-1S / 1C Series OWNER S MANUAL 9002-SW

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY

PLATINUM PRO1000V DIGITAL COUNTERTOP / PORTABLE BALANCE

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

TL-Series. User Manual. American Weigh Scales. TL-330 (330lb x 0.2lb) TL-440 (440lb x 0.5lb)

User's Manual Sound Level Alert Model SL130

Crane Scale. Revision 1.4 February 18, Transcell Technology, Inc. Contents subject to change without notice.

Torque Meter. Instruction Manual

FG-7000 Digital Force Gauge Operation Manual

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

Digital Kitchen Scale

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

PLATINUM PRO6000 PROFESSIONAL SERIES DIGITAL COUNTERTOP / PORTABLE BALANCE

Digital Bench Scale. Revision 8.93 August 12, 1993

PLATINUM PRO1001DXP DIGITAL COUNTERTOP / PORTABLE BALANCE

Bluetooth Headset user manual

L610 L620 L630 SIMPLE LOGGER THERMOCOUPLE MODULE E N G L I S H. User Manual

Automatic Phone-Out Home Monitoring System

Torque Meter. Instruction Manual

H-1671 REFERENCE. The scale is powered through the included power adapter. The scale can be powered by six AAA batteries (not included).

4-20/10-50 ma/v Loop Calibrator

805HP. Handheld Digital Weight Indicator User s Manual (v1703) Anyload Transducer Co. Ltd Website:

LG Electronics BLUETOOTH Mono Headset HBM-760 / HBM-761 User manual

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

Operation Manual for OLS-1315 Optical Light Source

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

QC-3265 Checkweigher User s Manual

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

HI HI HI HI Portable Microprocessor Thermistor Thermometers

CONTENTS. PRECAUTIONS Introduction Installation... 7

OPERATING INSTRUCTIONS

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

MWP SERIES. High Precision

User's Guide. Vibration Meter and Laser Combination Tachometer Model

EDGE. Digital Kitchen Scale. 11lb x 0.1oz 5000g x 1g

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

HI HI N HI HI

MODEL PS 150 PS 400 DIGITAL RECEIVING SCALE Operation Manual

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

600 g x 0.02 g DIGITAL BALANCE

CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...

S-2000 OWNER S MANUAL

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

General Warranty. For more details, please refer to the user manual, it can be downloaded at

User s Guide. 600A AC Clamp Meter. Model 38387

Barnant Company. Humidity Data Logger MODEL NO YR MIN HOLD MO MAX DAY STORE LOG RECALL PRINT C/ F PRINT SETUP.

4-Channel Thermometer

FUNTRONIX SCORE-N-TIME TM. T-240/T-260 Universal Up/Down Clock/Timer OPERATING MANUAL. Revision July 5, 2015

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

BATTERY MAINTENACE ERROR MESSAGE SPECIFICATIONS... 22

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

CR87B TEMPERATURE RECORDER

Digital Measurement Metrology, Inc PRECISION IS OUR VISION

Ohm Metrics Surface Resistance Testing Kit Model SRM500K

KERN FOB. non-approval. KERN & Sohn GmbH. Service Manual Electronic Precision Balances Page 2. Version 1.0. Tel: 0049-[0]

Price Computing Scale ER Series

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

LG Electronics BLUETOOTH Mono Headset HBM-210 User manual

Adam Equipment. CPWplus RANGE OF SCALES (P.N. 9009, Rev. B, May 2008)

Compact Balances. EK-610j EK-6100j. in an Authorized A&D Dealer

KUHLMAN INSTRUMENT COMPANY 5000K WARRANTY

Service Manual. Operators Manual. Ultegra Health Scale by Fairbanks Scales, Inc All rights reserved Revision 7 04/17

WM-25 USER S MANUAL. Manufacturer s Declaration of Conformity

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

GARNET. SEELEVEL II TM Tank Monitor INSTRUMENTS LTD. Model 709 Owner s Manual IMPORTANT OPERATOR INFORMATION DATE INSTALLED: SERIAL NUMBER:

Digital Weight Indicator Setup / Operation Manual

CA846 THERMO-HYGROMETER ENGLISH. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Operation Instructions

General Warranty. For more details, please refer to the user manual, it can be downloaded at

PRO 360. Owner's Manual

-Direct.com FG-3000 Digital Force Gauge Operation Manual

Transcription:

CC240RF COMPUTE-A-CHARGE WIRELESS CHARGING SCALE MANUAL

GENERAL INFORMATION Table of Contents General Information 2 Operation 3-9 Key Funtions 3 Display Screens 3-5 Weigh Mode 5 Charge Mode 6 Recovery Mode 6-7 Additional Features 7 Troubleshooting 8-9 Warranty 10 The CC240RF is an advanced, battery operated, WIRELESS weighing and charging scale. It has been designed to be accurate, rugged and reliable over a large weighing span (240 lbs / 110 kg). It incorporates a wireless display and control unit with 3 keys and an extra large LCD display for easy viewing. The scale platform incorporates a corner adjusted, heavy-duty load cell. 2.4 GHz wireless technology interconnects the display and control unit and the scale platform. This wireless scale system has a range of 30 feet (9m) CC240RF Specifications Working Load Capacity Overload Warning Operating Temperature Operating and Storage Humidity 110 kg / 240 lbs 110 kg / 240 lbs 14 F to 122 F or -10 C to 50 C 0 to 95% non-condensing Resolution.25 oz (10 g) Accuracy Display & Control Unit Batteries Scale Platform Batteries Battery Life Battery Indicator Weight RF Frequency Range RF Transmission Range Warranty +/- 0.05% of reading or +/- 0.25 (10 g) whichever is greater One 9V alkaline (ANSI 1604AC-IEC 6LR61) Four AA alkaline (ANSI 15A-IEC LR6) 32 hrs. of continuous use Battery symbol with 3 segment Power Level Bar Graph 8 lbs 15 oz. (4.00 kg) with batteries 2.4 GHz, ISM band 30 feet (9m) 1 year Calibrated to NIST traceable standards 2

Key Functions NOTE: Every key press received by the scale platform is acknowledged with a beep. If you have lost connectivity, there will be no beep from the scale platform and the display may freeze. It will be necessary to re-enter the key stroke when you are within range and connectivity is restored. POWER [ ]: Turns the display and control unit as well as the weighing platform ON or OFF. Press once to turn power ON, if the display and control unit is OFF. To turn OFF press and hold until a beep is heard and CPS OFF appears on the screen (See Fig. 11). This turns off both the scale platform and the display and control unit and also clears all memory and settings. Your body is an effective absorber of 2.4 GHz energy. DO NOT STAND WITH YOUR BACK TO THE SCALE PLATFORM! Do not turn the display and control unit OFF if connection to the scale platform has been lost. LB / KG (UNITS): Momentarily press to toggle units between Imperial and metric units. TARE: Momentarily press to tare the weight on the platform. The weight display returns to zero. Display Screens The CC240RF can be used for weighing, charging and recovering refrigerants. The following are instructions on how to use the CC240RF for common refrigeration service functions. You must be within 5 feet to initially connect to the scale. Range extends to 30 feet when connected. Turning the system ON and linking with the weighing platform: Press the POWER [ ] key in the display and control unit. The following series of screens will appear as the display and control unit establishes communication with the weighing platform. A lot of useful information is displayed in the screens in the following figures. 3

Figure - 1: Displays the software version of the unit. Figure - 2: Automatic Power Off enabled. Press [TARE] key to change. (See page 8 for details) Figure - 3: Shows the display and control unit battery voltage. Figure - 4: Count down to connect with the scale platform on channel 0. Figure - 5: Connection established. Displays software version of scale platform. Figure - 6: Scale platform Automatic Power Off status. 4

Figure - 7: Scale platform battery voltage. Figure - 8: Notifies the user that a zero calibration is being performed. Figure - 9: Notifies the user that a full scale calibration is being performed. Figure - 10: Instrument is ready to be used. 1. Place the weighing platform on a level, rigid surface. 2. Press POWER [ ] key to turn the unit ON, any weight on platform will be set to zero. (See figures 1-10 for the screen squence while CC240RF turns on). 3. Select the desired unit by pressing the [LB / KG] key. 4. Place the object that is to be weighed on the platform. Weigh Mode 6. Gross weight will display. 7. When weighing has been completed, press and hold the POWER key for 4 seconds to turn the unit OFF. 5 Figure - 11: Press and hold the POWER [ until this message is displayed on the screen. ] key

Charge Mode 1. Place the weighing platform on a level, rigid surface. 2. Press POWER [ ] key to turn the unit ON any weight on platform will be set to zero. (See figures 1-10 for the screen squence while CC240RF turns on). Figure - A 3. Select the desired units by pressing [LB / KG] key. 4. Place cylinder on scale and connect scale as shown in Figure-A. The display will show the weight of the Freon plus the weight of the cylinder. Press [TARE] to zero the scale platform. 5. Open the cylinder valve and all other valves that are in the charging pathway. 6. The display will show the amount of refrigerant leaving the tank. 7. When the desired amount is reached, close the cylinder valve and the valves in the manifold. 8. Press and hold the POWER [ ] key for 4 seconds to turn the unit off. 1. Place the weighing platform on a level, rigid surface. 2. Press POWER [ ] key to turn the unit ON any weight on platform will be set to zero. (See figures 1-10 for the screen squence while CC240RF turns on). 3. Select the desired units by pressing [LB / KG] key. Recovery Mode 4. Place cylinder on scale and connect scale as shown in Figure-B. Note the weight of the empty tank. Do not press [TARE] to zero the scale platform. When recovering refrigerant do not exceed the maximum tank fill weight. This weight equals the empty tank weight plus 80% of the water capacity weight. The water capacity weight is usually stamped on the tank. Figure - B 5. Open the cylinder valve and all other valves that are in the recovery pathway. This allows the flow of refrigerant to the refrigerant recovery unit. 6

Danger - the recovery cylinder used contains liquid refrigerant. Overfilling of the recovery tank may cause a violent explosion resulting in severe injury or even death. 6. Turn on the refrigerant recovery unit. Follow the recovery unit s instructions. 7. If the recovery process finishes before the weight reaches the maximum tank fill weight, close the cylinder valve and all other valves that are in the recovery pathway. (Go to step #10) 8. If the maximum tank fill weight is reached before the recovery process is finished, stop the recovery unit; close the cylinder valve and all other valves that are in the recovery pathway to the cylinder. 9. Exchange the cylinder with an empty one and proceed back to STEP 4. 10. When the recovery operation is completed, stop the recovery machine, close all the valves in the recovery pathway and press and hold the POWER [ ] key for 4 seconds to turn the unit OFF. Battery Life Indications [ ] : Additional Features The battery life remaining in the scale is shown on the LCD as a battery shape with 3 segment bar graph. 3 segments of Bar Graph Battery at 100% to 80% 2 segments of Bar Graph Battery at 80% to 60% 1 segment of Bar Graph Battery at 60% to 20% 0 segments of Bar Graph Battery at 20% to 5%, recommend replace LO CELL displayed on LCD Battery below 5% Auto Tare and Overload Indicator Feature: The unit will tare off any weight less than (240 lbs / 110 kg) while powering up. If the weight is more than its capacity, the unit will display OL to indicate overload. The OL will also display when the gross weight is more than its capacity. For example: The unit starts with 230 pounds on its platform-display reads 0; placing 25 pounds makes the unit display OL. Auto Shut Off Feature: Auto Shut Off (APO) - The unit will automatically shut off after 10 minutes if the weight on its platform does not change by more than 1oz (40g) in that period of time. Pressing [TARE] key when the unit displays the message in Figure-2 toggles between APO ON and APO OFF. If the display and control unit is out of range of the scale platform and it turns off because of the APO, the scale platform will remain ON and subsequent connection will not be possible unless the batteries in the platform are removed and re-installed after a 60 second delay. 7

Troubleshooting The CC240RF has been designed with the rough conditions of service work in mind. However, it is a precision instrument and, as such, certain precautions need to be observed to enjoy the benefits of its performance for a long time. 1. Control and display unit does not turn on: a. Check for dead batteries. b. Check for reversed polarity. c. Remove 9 volt alkaline battery for one minute; replace battery, listening for the battery installed tones. The control and display unit will produce 2 beeps then 5 faster beeps. 2. Control and display unit fails to connect to scale platform: a. Make sure you are within 5 feet (1.5 m.) of the scale platform. b. Check for dead batteries in the scale platform. c. Check the polarity of the batteries in the scale platform. d. Use 4 fresh AA alkaline batteries. 3. Items 1 and 2 are satisfied but the control and Figure - 12 display unit still fails to connect: a. Place the control and display unit close to but not on top of the scale platform then press POWER [ ] key on the control and display unit. b. When the display gets to rf29 / CH x (See Fig. 4), press [TARE] the display will change to rf29/ OPEn (See Fig. 12). c. When the control and display unit connects to the scale platform and the display enters the weighing mode, press and hold the POWER [ ] key and then press the [LB / KG] key and release both. d. In addition to displaying the current channel, the display will compare 4 ID s between the control and display unit and the scale platform. e. The display will show the word Good in each case. If the ID s do not match then a new application ID needs to be programmed. Please, contact the factory for instructions on how to do this. Application ID: The control and display unit and the scale platform are paired together at the factory. This feature allows the scale platform to communicate only with it s paired control and display unit. Occasionally, is may be required to link the scale platform with a different control and display unit. Please, contact the factory for assistance with this function. Install Batteries: When the control and display unit is turned on, it will display the voltage of its battery (See Fig. 3). CPS recommends replacing the battery in the control and display unit with a fresh 9 V alkaline battery when the 8

reading is 7.00 VDC, although useful operation can be obtained with battery voltages all the way to 6.00 VDC. During operation, the amount of battery life remaining will be displayed in the battery symbol on the display. When the battery is correctly installed, you will hear 2 tones followed by 5 faster tones. After the control and display unit connects with the scale platform, the voltage of the battery pack in the platform will be shown on the display (See Fig. 7). CPS recommends changing the scale platform batteries when the reading is 4.5 volts, although useful battery operation will result all the way down to 4.2 VDC; always use a set of 4 AA alkaline cells. When batteries are correctly installed, the scale platform will product a 7 tone musical tune. Note : For optimum performance, always replace both the HHLD and the Scale Platform batteries at the same time. Ensure that you hear the appropriate tone, if not, remove, wait 1 minute and reinstall battery. Note : It is recommended that the HHLD and the Scale Platform be turned off prior to removing any batteries.removing a battery when the Scale Platform is connected to the Hand Held, may cause the system to hang-up.remove batteries from both devices if you feel you must remove a battery during operation. Low Battery Indication: If the system detects a low battery condition, the system will turn itself off in a safe condition. The display will show the word CELL and either rxxx or Lxxx. The r indicates the voltage of the scale platform batteries and L the voltage of the control and display unit battery voltage (See Fig. 3 & 7). The display then changes to CPS Abrt after a brief delay and then the system shuts off. External Interference: In the unlikely event that the CC240RF has difficulty maintaining connectivity or has numerous instances of the display freezing, no response to key entries, etc. the most probable cause is interference from other ISM band devices in the same channel. In that case, press and hold the POWER [ ] key and press the [TARE] key. To check that the channel has changed, press and hold the POWER [ ] key and then press the [LB / KG] key. The display will show all [4 id / Good] settings and then will show the new channel number and return to the normal weigh mode. This instrument contains one or more RF devices with FCC ID: X8BMT240, IC: 8826-MT240. This product conforms to the applicable parts of FCC Rule 15. 9

WARRANTY CPS Products, Inc. guarantees that all products are free of manufacturing and material defects to the original owner for one year from the date of purchase. If the equipment should fail during the guarantee period it will be repaired or replaced (at our option) at no charge. This guarantee does not apply to equipment that has been altered, misused or solely in need of field service maintenance. All repaired equipment will carry an independent 90-day warranty. This repair policy does not include equipment that is determined to be beyond economical repair. 10