MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

Similar documents
MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

MobilSwitch - Micro. 1. Operation: General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs

Mobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output

GSM HOME SECURITY SYSTEM

Comsec Protection Systems

UP200-GSM Intercom and access control unit operating on mobile GSM network

MSS-UP200-GSM Single Dwelling GSM Intercom Unit. Operation Manual. [Ver /5/2015]

SMS Transceiver V3 User manual

UP100-GSM. GSM based intercom and access control. Installation and user manual

SMS Commander Manual

Decode Data Communications GSM Key - User's Manual - Belgrade, November 2010.

ProCon GSM INSTALLATION AND APPLICATION MANUAL. ProCon GSM manual. .gsm-komunikatorji.com. for module version 1.4

DATA LOGGER (Version V1.3)

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software

: DOOR ENTRY UNIT. Programming Software USER MANUAL

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

User Manual Revision 1.02

JVA SMS Gateway User Manual

Model SFS01-V2 IMPORTANT! MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH

icex-cmtm General specs and Installation guide

A1000 GSM ALARM DEVICE

Installation and Configuration Quick Guide GoRugged M1000 MP

SOLO NX EXT COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS

ZD-VT1 User Guide. ZENDA GPS Tracker ZD-VT1 User Guide

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

GSM communicator GD-06 Allegro Complete manual

SOLO KP SOLO KP LCD COMPACT MULTI-APARTMENT GSM DOOR ENTRY UNIT USER MANUAL

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

GSM Controller BR160SM-2SMT-4A-A / BR161SM-2SMT-4A-A

ARDUINO BASED GSM/SMS Remote Control Unit USING. SIM800 GSM Module

Voice Fax. User Manual

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

GPRS Pager 3 INSTALATION AND USER MANUAL

GSM SECURITY AND CONTROL SYSTEM ESIM021

MANUAL 3G GATE OPENER

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Installation & User Manual For Cell Box Switch. GSM Cellular Gate opener and GSM alarm signalling device.

GD-02-DIN Universal GSM communicator and controller

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

Communi-Cell Communicator Nokia Version

Installation Manual & User Instructions. MultiCom 500

ecoline GSM Adapter INSTALLATION AND APPLICATION MANUAL for module version v2.0 and higher Document version:

AV-4000 GSM AV-4000 DVR

Industrial Tri-band 3G Modem GTM-201-3GWA Series. User Manual

DinBox M36 Hardware Description Guide

Cellular Alert PRO PRODUCT MANUAL

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher

PHOENIX CONTACT

WiLARM-ContactID GSM Module Installation Guide Version: 2.0

TELTONIKA ModemCOM/G10 (CM1100) User Manual V0.1

GTM-204M-4G Industrial 4G LTE Modem User s Manual V1.0 High Quality, Industrial Data Acquisition, and Control Products

Digital Keypad Introduction

-SMS Alert Gateway. EzSMS-Lite USER S MANUAL

GSM communicator G16 USER MANUAL

GSM CODELOCK ACCESS CONTROL UNIT

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

MODEM for REMOTE SWITCH CONTROL V1.20

STD Simple Telemetry Application. Owner s Manual

VMB1RY. Relay Module for VELBUS system. Velbus manual VMB1RY edition 1 rev.1.0

SafeLine GL5. Installation manual. A GSM alternative for all of our lift telephones with built-in power supply and battery backup.

EA-GSM-Interface-GB.odt

MEITRACK MVT340 User Guide

TELTONIKA ModemCOM (TMC-10x) User Manual V

Cinterion BGS2T (RS232) Terminal Starter Kit. Getting Started Guide

RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software. v

GSM module G10T (v.2.3x) Installation manual. TRIKDIS, JSC Draugystės st. 17, LT Kaunas Lithuania

The Packs Infotel. GSM Converter V2. Installation Manual V7

Gate controller GC1000

180 Series Keypad. Handbook. Revision 2.1

page A.0240 Full_Product_catalogue_ BM.indb 110

GCR-16 with internal modem GXR user manual appendix J

Installation Manual & User Instructions

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents

GC 055. GSM Remote Monitoring. Operating and installation instructions

- Electronic Limit Switches - Very Accurate - Easy to use - Robust - Dependable - High Resolution - Non Contact Measurement - Wide Temp.

: DOOR ENTRY UNIT USER MANUAL EIS-R. Programming Software. v

A TECHNICAL INFO A. External GSM AT420 DATE :

: DOOR ENTRY UNIT USER MANUAL. Programming Software. v

EasyCon GSM. Installation manual

Quick Start Guide REX 100 3G LTE. Version. 2 en. as of FW

GSM Controller BR160SM-Sd BR161SM-Sd V1.2

rev mobile device to remotly control your home 2010 Cybrotech Ltd

SOFTWARE VERSION 3.3. CD P/N Rev. C

USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

GC-10 Wireless Control Box. User Guide

GSM PAGER VT 21. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC,

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data

Cellcop Communicator CP72u-M

HI GSM Supervisor. Instruction Manual

4 Channel GSM Controller Installer Manual

NX21 USER MANUAL. Telemetry Unit. Version 1.5

U-FLASH Setup Guide U-FLASH.

GM-900 GSM/GPRS modem. Application manual

Transcription:

MobilGate - 128d Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers MobilGate-128d is an industrial GSM module developed for remotely controlling doors, garage doors and barriers with 2 voltage-less contact type inputs and 4 low voltage low current relay outputs. The 2 relay outputs allow the configuration of 128 phone numbers to control the gates remotely with a free call based on caller ID recognition. The 2 relay outputs can be triggered by SMS orders received from previously configured phone numbers. Relays operated with a free call can be triggered for pre-determined duration, and the relays operated with SMSs can be turned on and off permanently. The recognition of maximum 128 phone numbers allows to set up entitlements for 128 users. The general inputs can be used arbitrarily for transmitting gate error signals, burglary alarm center's signals or panic signals. Users are informed about input changes via SMS with pre-configured content. Certain electronic devices, such as heaters, air conditioners, light devices etc. can be turned on and off with relay outputs operated via SMSs, thus the function of gate opener can be broadened with many supplements. Its power voltage is 10-30Vdc, which can be supplied by a power adapter. Its setup can be configured with our free downloader software via USB port, or by sending several different configuration SMS remotely. Each input and output can be labeled with a max. 16-character long name. The configuration of the SMS relay output commands which trigger the relays to be on or off also can be set. The module has a 4-character passcode in order to prevent any unauthorized personnel to disable or reconfigure the module. The module has internal timers, thus the output relays are triggered for a configured time when calls occur, which can be maximum of 9999 seconds (about 3 hours). After the given time expires, the relays turn off automatically and return to their original state. 1. Operation of MobilGate-128d The GSM gate opener is equipped with a carrierindependent industrial GSM module; thus it is ready for an SMS communication with a prepaid or subscription SIM card without PIN code. The data which is necessary for operation, for instance SMS number of the service provider, users numbers, output and input names etc. can be configured by downloading them into the device or sending an SMS with a certain content. In the case there is any change of the inputs, the module name, module number, the appropriate input name and status are also sent via SMS. The detailed messages provide possibility to be able to easily identify the appropriate device in case of having more than one. Input and output status with every parameter can be queried by sending a corresponding SMS. Configuration SMSs are confirmed after reception, and and an correct configuration SMS will result in an error message. The module does not discard the previously set

configuration, including input names, output status, phone numbers, etc. after turning the it off. After power-up, although timer parameters are deleted, but the module continues itsoperation where it stopped. The module checks the GSM modem regularly and turns it off in case of network or signal problems, then turns it back, connects to the network again, restoring itself into operating state. The Mobilgate-128d GSM gate control module can be purchased in a package with downloader software and aerial. The panel version is called MobilGate-128, its enclosure version is called MobilGate-128d and the version that can be installed to a C-rail (DIN-rail) with opto-isolated inputs and with 4 pcs of high current relays is called MobilGate-128c. It can be equipped either with smaller, rectangular dual-band stick antenna or with magnetic, screwable external antenna equipped with RG174 SMA-connector. 2. LED diode signals LED diodes can be found on the side of the panel in order to indicate possible error messages in the following order: Red "On" LED Continuously: White "GSM" LED Blinking Green "Heartbit" LED Blinking Yellow "Busy" LED Continuously The interface is operational. It has to remain lit after turning it on. GSM module operational status. It has to light up after around 25 seconds then flash according to its functioning. Its flashing indicated that the device is connected to the network. It is the life signal of device. When the device is turned on, it does not blink until the device is connected to the network. It starts blinking after the device is connected to netork. The number of flashes (0 to 10) indicates the signal strength. 0 flash means the device is not connected to network, 2 or 3 flashes mean low-signal and it occurs when GSM connection is not secure. 4 or more flashes mean sufficient signal strength for operation. In the case the green LED doesn t light up after 1 min, the modem could not connect to the network at all. The aerial and SIM card have to be checked, e.g. the SIM card is protected with SIM PIN. It is on during device communication.

3. Connection and installation of the MobilGate-128d The connection points of the interface can be found in the figure below: Up: Antenna USB connector Down: Relay outputs Input connectors Power supply connector The power connection needs 10-30V DC supply voltage. The inputs of the MobilGate-128d GSM gate controller can be triggered by voltage-less contact on the simple inputs. The numbering of the module inputs is marked on the board of printed circuit. It has high current No-Com type relay outputs and their max load is 48V and 1A. The No and Com points of the relays are wired out. The GSM modem has a screwed SMA aerial connector and a small-sized straight pole aerial or an aerial with a coax cable or similar plug can also be installed to it. The power input of the GSM gate opener module is protected against reverse polarity and it is equipped with 500mA multifuse. The input voltage on the general purpose inputs ranges is from 5V... 30Vdc. 4. Configuring MobilGate-128d using a computer: MobilGate-128d can be configured with computer or notebook via USB-port by using our free software. A SIM card that is able to send SMS and it is not protected with PIN code has to be isrequired for Windows XP or any newer operation system. After driver installation, the next step is inserted into the module. When the device is connected to the USB-port, the module driver has to be

installed from the CD or it can be downloaded from www.seasoft.hu. Installing the gate controller module driver the serial port configuration. It starts by clicking the Set Port button. Windows registers the device and assigns it to a COM-xx port. The software indicates module version and enters configuration mode. The user can configure MobilGate-128 controller freely in configuration mode. If the software cannot find the port of the device indicated on the picture, it has to be identified manually in Windows by the followings: -> Control Panel -> System -> Hardware -> Devices -> Ports The GSM device has to be identified by which serial port from Com1...Com99 it is connected to. Manual configuration is necessary when previously a lot of USB devices had been connected on the computer. In this case the device might not be in the range of Com1..99 Start the software then set the Com value in Settings -> Port configuration menu. The download software of MobilGate-128d offers a fast and simple way to configure the device. Menus appearing on the screen allows the access to the most important functions. Not only downloading the configuration into the device is possible, but also the actual configuration can be readrom gate controller. If the data has been modified since the last download i.e. by SMSs, it can be read and checked. It is advised to always start configuration with a file named Default.mob. It is easier to edit uploaded data without making any mistake than creating new values. It is important to fill out the required fields and avoid the use of accented characters for names and commands because the module does not recognize accented characters. Fill the phone numbers in international format without the + sign! Loading data into the device can be started by clicking the green Dowload into Device button.

The successful download will be indicated in a pop-up window. The pop-up window contains a corresponding error message if the download was unsuccessful. Unsuccessful download can happen in case of connection failure between the computer and device. By clicking on the button named Read from Device the previously downloaded data can be read, and it results in overwriting data on the screen with the uploaded data. It is advised to check downloaded data with the yellow-colored Verify Download button. The Check Status function queries the device for network connection status, input and output status and possibly the name of the service provider. Relay functions can also be checked manually. Click on Menu -> Device -> Relay test, where relays can be triggered manually

which is shown by the output status on screen located below the inputs statuses. The software can handle every version of the MobilGate family. It automatically recognizes the 32 and 128 version of the device family and it allows to open the group of mobile numbers beyond 32 in case of the 128 version. After finishing the configuration, reset the module to verify the changes. It can be done by clicking on the Restore to normal operation mode button The GSM module quits configuration mode and resets to normal mode. After restore, it restarts automatically, switches back to normal operational mode, connects to the network and (after less then a minute) when the green LED starts to blinking, it becomes fully operational again. 5. Configuring MobilGate-128d by SMSs Considering that MobilGate-128d is a complicated device, it is advised to configure it with the download software. Simple changes (e.g. adding or removing a phone number) can be done remotely via SMS. It is necessary to know the memory map of the device for configuration: MobilGate-128d - functional memory map Memory Function / contents Remarks Default Progr. samples 00 Provider's SMS center number International format - - - 36309888000 01 Device PIN code 4 characters 1234 9876 02 Device identifier 4 scharacters 0001 0007 03 Name of device My house My castle 04 Restore report of inputs 0 = no, 1 = yes 1 1 05 Name of input 1 Gate Barrier 06 Name of input 2 Pushbutton Alarm system 07 Relay's switch-on time Between 0...9999 sec 0005 0012 08 Switch-on SMS command of relay 3 Light on alarm on 09 Switch-on SMS command of relay 4 Buzzer on syren on 10 Switch-off SMS command of relay 3 Light off alarm off 11 Switch-off SMS command of relay 4 Buzzer off syren off 12 Switch-on SMS from Input 1 motor error barrier trouble 13 Switch-on SMS from Input 2 pressed in alarm status 14 Switch-off SMS from Input 1 motor ok barrier ok 15 Switch-off SMS from Input 2 released end of alarm

The module confirms every SMS command with a response SMS. Do not send any further SMS commands until the confirmation SMS is received, because it might be lost and will not be executed! The confirmation SMS shows the changed parameter and the actual status of inputs and outputs. If the given command is wrong, the module cannot recognize it, thus an SMS with the content of Error! will be sent back. Please configure the SMS center number first during configuration otherwise the device will not respond for certain configuration commands and will not operate correctly. Add the SMS center number first, because confirmation SMS will get back about its sending as well: i.e.!1234,w00,36309888000 where 1234 device PIN W00 memory place means SMS center number 36309888000 SMS center number in international format (here hungarian T-Mobile) i.e.!1234,w01,5678 where 5678 device PIN W01 memory place is PIN code giving command 5678 new PIN code i.e.!1234,w02,5566 where 5566 new device ID W02 device ID memory place i.e.!1234,w11,syren where syren off message to be sent by the device in case of output 4 switch-off W11 memory place is content of the SMS in case of output 4 switch-off MobilGate-128d - functional memory map (continued) Memory Function / contents Remarks Default Progr. samples Inputs 1 st character (starts SMS) Outputs 2 nd character (switched by call) Telefon number 3 rd - 13 th character 0 = none 1 = only 1st 2 = only 2nd 3 = both (1 st and 2 nd ) 28 2 1 1 st telefon number --- 2,1,36209876543 29 3 2 2 nd telefon number --- 3,2,36301234567 30 3 rd telefon number --- 31 4 th telefon number --- 32 5 th telefon number ---...... ---...... --- 154 127 th telefon number --- 155 128 th telefon number ---

i.e.!1234,w29,3,2,36301234567 where 3 (the first 3 characters).means that this phone number will be informed about both input changes 2 (second character) means that only relay 2 will switch on for the given time when called. 36 30 1234 567 (last 11 characters) means the phone number on memory place 29. Using the two tables above with the same logic with using the correct syntax for the given memory space, every memory space can be loaded via an SMS. Default settings remain in the unchanged memory spaces. Loading memory spaces by SMSs can take some time, therefore it is advised to use only for remote configuration. 6. Query SMS commands: i.e.!1234,r00 where R00 the 00 th memory place of the device (see table) carrier SMS number can be queried. i.e.!1234,r28 where R28 the 28 th memory place of the device (see table) first user phone number can be queried. i.e.!1234,r where R if there is no number after it, it shows device status. Response SMS in case of Default settings: 1234 My house Gate: motor ok Pushbutton: released Light off Buzzer off This SMS informs about: the valid device PIN code - 1234 the actual nema of device - My house the name of 1 st input - Gate the status of 1 st input - motor ok the name of 2 nd input - Pushbutton the status of 2 nd input - released the status of sms switchable relay no.3 - Light off the status of sms switchable relay no.4 - Buzzer off 7. Output configuration commands i.e. Light on where Light on command is on M09 memory place command which (see table) is the retraction command of relay 3. Relay 3 will turn on. Attention! The device will execute the given command if it is identical to the command given in the memory. If the sent SMS does not match with any SMS command, the module will send back an Error! message.

8. Further notes Regarding to the device functionality, GSM networks and the specialty of GSM voice calls and SMS-s, the module requires further remarks: a) The device can be operated with any microsim card b) The received unknown SMS-s, including the ones sent from the carrier (including the balance check SMS) are forwarded to the first telephone number, if the first telephone number is specified in the configuration. c) If a pre-paid SIM card is used and the balance reaches zero, the device can remain operational however it cannot send further SMS-s or initiate calls. In this case it is advised to regularly check the balance of the card. d) After downloading a configuration from PC via USB, the device will restart which takes 30-40 seconds, and it will be operational after registering to a GSM network. e) All members of the MobilGate family can operate only with SIM cards that are not protected with PIN codes. Please note that the SIM PIN is not equal to the module PIN number. f) Before device use, the PIN code has to be removed from the SIM card. g) By using pre-paid SIM card, showing the caller ID must be enabled. This can be performed by contacting the carrier s customer service. h) Call-forwarding and SMS reminders about missed calls sent by the carrier must be disabled on the SIM card. 9. Connecting the MobilGate-128d Specifications: Power supply: 10 30 Vdc Max. Current: 290 ma Stdby (relays on): 27 ma Stdby (relays off): 135 ma Operat. temp: -30..+70 C GSM: Dual band Freq: 900/1800MHz Comm: SMS, voice Aerial conn.: SMA Enclosure: alu enclosure Dim: 83x71x24 mm SeaSoft Ltd. - 2013 -

Appendix: modificatons of of setting of USB serial Com port in Windows-7 (step-by-step)