Traction Power Systems / Program

Similar documents
DC Substations / Supply Program

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

////// SUBSTATIONS. Voltage Limiting Device. VGuard

////// SUBSTATIONS. Control command and local Scada

////// SUBSTATIONS SCMS. Stray Current Monitoring System

////// SUBSTATIONS SEPCOS. Control and protection relay

EFASOLAR PVStation Solutions

Benefits, offering and references

Specification Voltage Limiting Device

Grid Automation packaged solutions Optimal automation of medium voltage grids

POWER GRIDS. We are bridging the gap. Enabling Digital Substations.

IDS SAS. Station Automation System for Complex Applications

High-Speed DC Circuit-Breakers rolling stock Type UR26, UR36 & UR40

Est Constant Current Regulator MC4 3kW 30kW

Presented by: Oscar Araujo Photovoltaic Solutions Manager. 4 th Canadian German Solar PV Conference March 2 nd 2011

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

For Transmission, Distribution and Machinery protection.

UniGear type ZS1. SSC (Switchgear System Connectivity)

UniSec, MV AIS for Secondary Distribution Smart Grid applications

Air-insulated medium-voltage secondary distribution switchgear

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

Products Portfolio. Pole mounted Vacuum Recloser

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

iswitch imotor Compact QR

ISIO 200. Binary Input/Output (I/O) terminal with IEC interface

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

MESP MODULAR SUBSTATION USER REQUIREMENTS

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

VIP 40/45 VIP 400/410

PRODUCT FEATURES AND ADVANTAGES

Energy Storage Systems Utilizing the SunDial Plus 30PV+S Inverter

aentron Energy System 1 to 900 Vdc

Automation System Solutions

High Safety low voltage switchgears For maximum requirements far beyond all standards.

PROTECTION RELAYS: INNOVATIONS FOR THE BENEFIT OF THE USER

Package Substation. The efficient solution for your electrical distribution network

SCADA Training - T&D Automation

PREFABRICATED SUBSTATIONS AND E-HOUSES. tgood.com. Energy, Fast!

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)

MINER-S Station Controller

SICAM RTUs Ready for the Future

Feeder/ Motor Protection Relay VAMP 40

Substation SCADA Monitoring

This image cannot currently be displayed. Sarel Pelser. ABB Group May 27, 2014 Slide 1

Grid Automation Controller COM600 How it fits into the Smart Grid?

PRODUCTS AND SERVICES. At a glance

Make the sun your energy source. SOLAR

POWER GRID AUTOMATION. Pág.. n. RMU Automation

Scout-S Station Controller

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

Est Static Transfer Switches STSt A STSi A

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

PSSS/PSAC Engineering, Muhammad Adil, Substation Automation Systems. ABB Group October 29, 2014 Slide 1

Power supplies.

Est Constant Current Regulator MC2 3kW 30kW

Solution Railway. tgood.com

Quasar Series Technical Features

SM100. On-Line Switchgear Condition Monitoring

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Innovation on Medium Voltage Switchgear

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

What fulfills the highest demands on the current and voltage quality?

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Synchro-check relay. Application

MEGADRIVE-LCI. Medium voltage AC drive for control and soft starting of large synchronous motors

CONTENTS... 2 COMTROLL SAS. SURVEILLANCE AND AUTOMATION SYSTEM...

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

Company main topic [ Product ] TracFeed DCP2. English. Multifunctional Device for Control and Protection in DC switchgear.

Battery charger. Power plants. Substations. Rail and infrastructure. Industry. Thyristor controlled with controller GMU

MiCOM P122C Time-Overcurrent Protection

Equipment Strategy For High Voltage Circuit Breakers

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

Modular Smart Grid Power Systems Simulators (Utilities)

ROCON RPC 116. SUBSTATION AUTOMATION Central unit for substation automation

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Electrical Integration with Smart Communication

Sigbert Reimann, Remote Control Forum, Datum 9. October 2013 RTU - Review and News. ABB Network Management Forum December 10, 2013 Slide 1

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Protection relays.

SIGMA. Advanced Generator Protection and Control. Short Form Catalogue

Solution Renewables. tgood.com

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Air Cooled Medium Voltage AC Drives ALSPA VDM6000

Feeder protection relay SPAA 121 C. Product Guide

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

CABLETROLL 3 CABLETROLL CABLETROLL CABLETROLL CABLETROLL LED-2 5 CABLETROLL CABLETROLL REMOTE INDICATION 7

L S T LLOYD SYSTEMTECHNIK IREG. The Latest Generation of Digital Voltage Regulators. Concept. Firmware

Siprotec 7ST61 / 7ST63

AUTOMATIC NETWORK RECONFIGURATION IN SPLIT AIRPORT pilot project of complete MV grid automation

INTER PLANT STANDARD STEEL INDUSTRY

INTRODUCING THE S V ADJUSTABLE SPEED DRIVE

Transcription:

Traction Power Systems / Supply Program

Sécheron offers an extensive range of products for DC electrification of public transport This document is intended to give a brief idea of our services, cubicles and systems in the field of DC traction substations. Detailed brochures are available for all products. ENGINEERING SERVICES /// COMPUTER AIDED SIMULATIONS AND CALCULATIONS Dynamic simulation of power consumption and complete network analysis, taking into consideration all characteristics of the vehicles and the network. Substation positioning and total energy consumption including energy storage and/or inverter solutions. Conformity study with applicable standards. /// DESIGN AND CONSULTANCY SERVICES Harmonic filter design for DC networks. Concepts of protection (overhead lines, earthing, bounding, selectivity, etc.). Consultancy service to define technical specifications including transformers and medium voltage switchgear design. /// PROJECT MANAGEMENT IPMA (1) Certified project managers /// RAMS (2) STUDIES /// OTHER SERVICES Supervision of installation. Commissioning. After-sales service. Maintenance. (1) IPMA = International Project Management Association (2) RAMS = Reliability, Availability, Maintainability and Safety 2

EFFICIENT POWER CONVERSION TRANSFORMERS Based on a strong experience, Sécheron provides an engineering and consulting support service for the transformers, including specification, monitoring during the manufacturing process and assistance. Sécheron is also able to calculate the main characteristics of traction transformers. They are adapted to the client network configuration, being 1 or 2 secondary windings, cast-resin or oil-immersed transformers, self cooled or forced air, with a 6, 12 or 24 pulses system. The transformer core and windings are manufactured in accordance with the best modern practice to withstand the stresses of heavy traction cyclic loading and track faults. To ensure a good harmonization, Sécheron is able to provide the complete transformer-rectifier group. RECTIFIERS REC Type / Design Diode rectifiers REC-D Power Rated voltage Fixed mounting 900 to 6000 kw 500 to 3000 VDC Withdrawable 900 to 5000 kw 500 to 3000 VDC Special design Up to 10 MW More than 3000 VDC Up to 6 MW 750 to 3000 VDC Controlled rectifiers REC-C Variety of connections (3 phase bridge, 2 x 3 phase bridge, 6 / 12 / 24 pulses output). Protection (RC over voltage protection, Snubbers, Diode fuses, Over current protection). Cooling: Natural air. Mounting: Fixed or withdrawable. Possibility to integrate Inter-Phase coils. INVERTERS INV Type Rated power Rated voltage IGBT inverters INV-I 500 to 3000 kw 750 to 2000 VDC Thyristor inverters INV-T 500 to 4000 kw 750 to 3900 VDC Cost savings through recovery of the excess braking electrical energy. Reduction of heat in tunnels and substations g Reduction of cooling requirements g Further cost savings. Compatible with existing systems. Minimisation of CO2 footprint. Harmonization and integration with SEPCOS and Sécheron DC switchgear for protection, diagnostics and control. REVERSIBLE CONTROLLED CONVERTERS REV Based on the combination of our rectifier technology and our inverter technology, we are able to provide reversible controlled converters. 3

ESTRA DC SWITCHGEAR & DISTRIBUTION BOARD /// DESIGN The cubicles can be combined in various ways to complete substations, offering the systems engineer the greatest possible implementation flexibility. According to their design, they can be used as feeders, bus tie cubicles and for other applications. /// HSCB CUBICLE RANGE Full conformity and type tested according to EN 50123, IEC 61992 and IEEE Std C37.14 and C37.20.1. Integration of protection and control relays made by Sécheron (SEPCOS). Various configurations available: Rectifier Breaker, Feeder Breaker, By-Pass, Breaker... Possibility to integrate disconnecting or change-over switches. HIGH-SPEED CIRCUIT BREAKER PANELS MBS-HD Rated operational voltage Rated output current Rated current busbar 900 / 1800 V Up to 6000 A Up to 11000 A 900 V 8000 A Up to 11000 A 3600 V 4000 A Up to 11000 A /// DESIGN Compartmented metal enclosed cubicles with high speed circuit breaker mounted on a withdrawable trolley. Suitable for feeding applications for heavy DC railways networks. CIRCUIT BREAKER PANELS MBS-SECUB Rated operational voltage Rated output current Rated current busbar With UR15 900 V 1500 A 4000 A With UR26 900 V 2500 A 4000 A /// DESIGN Compartmented metal enclosed cubicles with high-speed circuit-breaker mounted on a withdrawable drawer. Delivered with trolley for maintenance purposes. Especially suited to all feeding applications for LRT, LRV and trolleybuses. DISCONNECT SWITCH PANELS PADS Rated operational voltage Rated output current Rated current busbar 900 / 1800 V 2000 to 8000 A Up to 11000 A 3600 V 2000 to 6000 A Up to 11000 A /// DESIGN Compartmented metal enclosed cubicles with one or more disconnecting switches. Suitable for all feeding applications for DC railway networks. Possibility to integrate a variety of protection: Frame leakage protection (64), Negative-earth protection (59), Return current detection (32). 4

ESTRA DC SWITCHGEAR & DISTRIBUTION BOARD VOLTAGE LIMITING DEVICES VGUARD During normal operation of railway system, dangerous voltage can occur across accessible points of the return circuit and earth due to the voltage drops along the return circuit caused by the current train traffic or insulation fault. In order to limit these voltages below the admissible values defined in EN 50122 1 standard, a voltage limiting device must be used as a short circuiter between negative and earth. Sécheron s voltage limiting devices (VGUARD) are recoverable devices which are compliant with the railway standards: EN 50526 2 (for voltage limiting device) and EN 50122 1 (for protective provision about electrical safety). Combined protection of personnel, passengers and installation. Prevention and elimination of dangerous voltage. Bidirectional operation and protection. Continuous monitoring of the potential of the return circuit. /// TWO MAIN VARIANTS VGUARD-B: Basic VGUARD with contactor. VGUARD-H: Hybrid VGUARD with contactor and thyristors. WAYSIDE PANELS Sécheron has designed its own range of outdoor wayside panels. These cubicles are designed to integrate one or several devices such as disconnect switches, load break switches, contactors or DC high speed circuit breakers. Depending on the customer specification, Sécheron can propose either steel or polyester wayside panels with a protection degree up to IP65. Two basic cooling methods can be applied: natural convection or forced convection. ISOLATED AMPLIFIERS & RELAYS MIU, VM & VP The MIU10 isolated amplifier is suitable for measuring high DC currents in power distribution systems for public transport networks. The VM10 and VM12 isolated amplifiers are suitable for measuring DC voltages in power distribution systems for public transport networks. /// MIU & VM10/12 MAIN FEATURES High voltage isolation, wide supply voltage range, low non-linearity error, very high immunity, high galvanic isolation, compact solutions, fuseless solution. The VP10 isolated relay is suitable for the detection of DC voltages in power distribution systems for public transport networks. /// VP10 MAIN FEATURES High voltage isolation, adjustable threshold, high galvanic isolation, intrinsic safety functioning, fuseless solution, diagnostic signal. 5

STELLA PROTECTION & SUPERVISION CONTROL & PROTECTION RELAYS SEPCOS SEPCOS is a micro-processor based equipment which satisfies the most demanding safety requirements applicable to DC traction distribution networks. Used as a control and protection unit, SEPCOS integrates the necessary functions for the protection, the control and the measurement of DC traction equipment related to transportation systems (streetcars, underground railways, commuter trains or trolley buses). Moreover, SEPCOS is stand alone, modular, extending, easily adaptable by software and widely open to modern communication equipment (IEC 61850, IEC 62439-3 (PRP/HSR), IEC 60870-5-104 (-5-101), DNP 3.0, Modbus-TCP, Profinet, Modbus-RTU, Profibus-DP). SEPCOS range includes different versions in order to offer the most appropriate functionality: SEPCOS Basic, SEPCOS PLC, SEPCOS Gateway, SEPCOS RTU, SEPCOS Compact and SEPCOS PRISM. /// DISPLAY The Display allows a complete visualization, control and parameterization of the equipment and collects the information available from the SEPCOS. Control and configuration actions are protected by password levels. /// S-WEB S-Web is an integrated web server within each SEPCOS. This interface is used to configure, visualize and analyze the data. This tool only requires a web browser and does not require any software installation on a computer. CONTROL COMMAND & LOCAL SCADA KEOPS The solution provided by Sécheron for local control and monitoring of traction substations is a significant step in supporting operations and maintenance of the power supply network. In order to meet high demands in reaction time and cost efficiency, the powerful control and supervision system is based on modern communication protocols and combined with user-friendly interface. In addition, all information, events, detection curves, substation history, diagnostic and documents are available to be transmitted to the centralized SCADA system of the network. The control command and local SCADA developed by Sécheron is a modular system designed for communication and/or control of each part of traction power substations. It allows required interactions between different panels of a substation using specific power network protocols and/or standard industrial network protocols. Supervision of the complete substation: Graphical display of measurement values, positions of breakers, alarm management, trending management, disturbance. Command: Command of all motorized devices including MV breakers and DC breakers. Parameterization: Parameter setting of all protection relays. Control: Possibility to define special control sequences. Wide range of communication protocols. 6

STELLA PROTECTION & SUPERVISION STRAY CURRENT MONITORING SYSTEMS SCMS The operation of DC traction systems requires suitable measures to prevent corrosion caused by stray currents on railway and non-railway installations. In this scope, the European standard EN 50122-2:2011 (Annex B) recommends a continuous supervision of the rail insulation. Sécheron s Stray Current Monitoring System (SCMS) is a straightforward and efficient method of stray current monitoring avoiding manual repetitive measurement and any interference with the stray current collecting system. The system measures continuously the rail-to-earth potential under operational conditions, complete with central analysis, visualization, signalling and archiving capacities. Data collection from VGUARD (real-time measurements). Alarm and localization of the detected insulation fault. Data acquisition and transmission through the communication network. Permanent automatic analysis of recorded values and manual analysis possible. Set up of network lines and stations, up to 100 control points. Determination on data reference. Integration of specific algorithm depending on the type of network. Export and backup of measured and recorded values. Communication with SCADA system. E-HOUSE ELECTRICAL HOUSES Sécheron is able to provide customized and complete DC traction substations in containers ready for use (transportable cabins or prefabricated buildings) that are built to withstand severe weather conditions and to shelter the equipment from any environmental influence. Providing the highest security conditions to the operating personnel, Sécheron uses perfectly the internal space of the container substations by incorporating equipment such as AC/MV equipment and traction transformers, DC equipment, rectifiers, DC switchgear, control command and other additional equipment. These containers require minimum installation and commissioning time. Depending on the customer specification, Sécheron can propose different versions of the container construction: either metallic or concrete prefabricated solutions. Our expertise and equipment also meet the needs of other industrial DC distribution applications, such as data centers or smart grids. 7

SG814318BEN_D03-09.18 Sécheron SA Rue du Pré-Bouvier 25 1242 Satigny - Geneva CH-Switzerland www.secheron.com Tel: +41 (0)22 739 41 11 Fax: +41 (0)22 739 48 11 substations@secheron.com This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser s responsibility to inform himself, no matter what the circumstances, of the product s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our General Delivery Conditions. Copyright 2018 Sécheron SA