Similar documents
CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

BMKC Controller for Parabolic Trough, 8 DI 12 DO 4 AI

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI

OnCell G3100 Series Quick Installation Guide

Click-A-Tune. User Manual

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

PLCADD1616 User Guide 3/29/10. Overview

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

Datasheet: com.tom INDUSTRY

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Matrix-710. Linux-Ready Cortex-A5 Industry IoT Gateway. Hardware Guide. Version: Nov.

Installation Guide Serial Interface T942SI

ISOLATED RS-232 TO RS-422/485 CONVERTER

Version 1.0c May 6, 2010 ATK3

EZ864 UMTS Terminal Telit Cellular GSM Engine

ADDJOG User Guide 7/30/10. Overview

RTU560 Connections and Settings DIN Rail RTU 560CIG10

MP211 HARDWARE MANUAL

General Operating, Maintenance and Installation Manual

BMKC Controller for Power Tower, 8 DI 8 DO 2 HSC

RTU560 Remote Terminal Unit Connections and Settings

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

Vision OPLC. Technical Specifications. V T34 Technical Specifications

Ethernet to Digital I/O +RS232 +Switch

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

RTU32S RTU32S Series Small Compact Utility RTU

User Manual. cmt-svr Startup Guide

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

CS485. User s Manual. Version ZYPEX, Inc.

Turck Cloud Gateway UMTS Gateway TCG20-UMTS-1ETH-CRS-01

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

JetBox 9300/9310 User Manual. Hardware

USER MANUAL COMBOX.M - Modular energy management data concentrator

Product description Rev. 3 11/06/14

iologik 2500 Series Quick Installation Guide

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

MRS Electronic GmbH. Datasheet CAN I/O & CAN PLC CAN I/O & CAN PLC. CAN I/O & CAN PLC Site 1 of 5 Version 1.0

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Netbiter EC300 Series

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

EZmoto V4.1 Product description Rev. 2 30/07/2015

GSM-PRO2: the perfect communicator GSM-PRO2-GPS. Input and output. Expansion modules

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

OnRISC Alekto 2 Hardware Manual

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

xpico Wi-Fi Embedded Device Server Evaluation Kit User Guide

MOTION COORDINATOR MC405 Quick Connection Guide

Data Sheet Rev DALLIS Serial Data

User Manual. cmt-svr Startup Guide

USB-COM Plus ISO (USB-COMi SI-M)

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

DinBox M36 Hardware Description Guide

POWERWISE INDAC SETUP MANUAL

CF Plug-In. Evaluation Board User Guide. Bulletin Revision Date

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

UK +44 (0) // USA // JAPAN //

UNDK 09. Ultrasonic distance measuring sensors. Sd = 200 mm. short response time internal and external Teach-in detects the smallest objects.

SXPi Linux box version 1.0

ARDUINO YÚN Code: A000008

TRP-C08 User s Manual

General Specifications. P2-SCM Serial Communications

User manual Compact Web PLC WP240 series IEC-line. update:

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Product Specification for SAB-S-MODBUS

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

MED102A. Industrial Serial to Single-mode Fiber Converter

USB to RS-422/485 Serial Adapter

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

USER MANUAL FOR GS100/GS1003G

NetBiter I/O Extender User Manual

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

SST-2450 Wireless Modem User s Manual

V350-T38 V350J-T38.

NTX Series Product Comparison

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

The DVT Ethernet IO Module (CON-IOE)

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

Installation and Configuration Quick Guide. R3000 Quad. Industrial Cellular VPN Router with 4 Ethernet Ports (4 Eth + 1 RS-232/1 RS USB Host)

Samba OPLC SM35-J-T20

User Manual for VE GSM Modem

Matrix-700 Linux-Ready Cortex-A5 Industry IoT Gateway Hardware Guide

CBL Starter Cable Kit for DuraNAV System

R O U T E R М Т 0 1 V e r s i o n v А Т O M e v e r i t h i n g n e w e m e r g e s n o w

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

UK +44 (0) // USA // JAPAN //

Transcription:

icex-cmtm General specs and Installation guide 1. General view 2. Specifications 2.1. Common specs: Ethernet 1 x 10/100Base/T, RJ45 connector with traffic and link LED Serial Interface 1 x RS232/485 USB Micro USB port (currently not in use) SD card Micro SD card (currently not in use) Operating system IPC@CHIP RTOS Operating temperature 0-55 ºC Size (W x L x H) 46 x 105 x 70 mm 1.8 X 4.2 X 2.8 Inch Mounting 35 mm DIN rail Additional function c/c++ 1

2.2. Specific ICX-CMTM-B2.0 properties: Modem Status LEDs 5 (power, Status A, Status B, Status C, Status D) CAN Interface Power supply Active current Analog I/O Digital I/O 10 30 V DC Max 100 ma @ 24VDC ICX-CMTM-B2.0 Typical installation icex B2 Ethernet External Modem 2.3. Specific ICX-CMTM-R3.0U properties: Modem Second Serial port CAN Interface Power supply Active current Analog I/O Digital I/O 1 x Quad band UMTS (3G) 850/900/1800/1900 MHz SIM card interface in the back None 1 x CAN 10 30 V DC Max 120 ma @ 24VDC ICX-CMTM-R3.0U Typical installation 2

2.4. Specific ICX-CMTM-R10.U properties: Modem 1 x Quad band UMTS (3G) 850/900/1800/1900 MHz (SIM card interface in the back) Second Serial port None CAN Interface 1 x CAN Power supply 24V DC ±15% Active current Max 280mA @ 24VDC Analog I/O 8 x 4-20 ma or 0-10 VDC (Each one set separately) Digital I/O 8 x Inputs (max 5mA)/ Outputs (max 500mA) @ 24VDC Additional functions 8 x Total / Resettable counters 8 x Real Time Flow Rate ICX-CMTM-R10.U Typical installation 3. Power connector assignment VCC 24VDC (+) GND 24VDC (-) Include circuitry to protect against reverse-polarity connections. 4. LEDs 4.1. Power LED Power LED indicates icex power supply status. 4.2. "Status A" LED "Status A" LED indicates the status of the connection to the monitor/control systems (drivers): Off-The initial LED status after power up. If it remains off it indicates that the icex has no requests for communication with the monitor/control systems. On-Communication OK to all monitor/control systems (drivers). Blinking-iCEX has a communication problem with at least one of the monitor/control systems. The LED starts blinking after three (3) unsuccessful retries. 3

4.3. "Status B" LED "Status B" LED indicates the status of the communication to the RealiteQ-COMP (Central Online Management Portal). Off The initial LED status (after power up) is off. On-iCEX is connected to the COMP and functioning normally. Blinking-iCEX has a communication problem with the server. 4.4. GSM LED "GSM" LED indicates the status of the cellular modem connection to the cellular operator Off The initial LED status (after power up) is off. On The modem is power-on and connected to the Cellular network. Blinking - connection to the Cellular network (GSM) in progress. 4.5. Connect LED "Connect" LED indicates the status of the cellular modem connection to the Internet. Off The initial LED status (after power up) is off. On The modem is connected to the Internet and functioning normally. Blinking The modem is in sign-in and connection procedures. "GSM" LED indicates the status of the cellular modem connection to the cellular operator Off The initial LED status (after power up) is off. On The modem is power-on and connected to the Cellular network. 5. SD card Currently not used. 6. Communication Ports 6.1. 10/100BaseT connection Standard 10/100BaseT RJ45 connector with 2 status LEDs: Yellow LED -Activity status: On-activity, Off-no activity. On in normal operation. Green LED -Link status: On link on, Off-no link. Blinking in normal operation. 6.2. RS232/485 combined interface Combined RS232/RS485 interface. The COM interface can be used alternatively as RS232 or RS485. A suitable cable should be used for the selected interface. The RS485/RS232 interface is not galvanic isolated. The Baud rate for both functions (RS 232and RS 485) is up to 250 Kbit/s and cannot be modified. The RS485 interface is setup for half duplex operation. Pull-up, pull-down and termination resistors for the RS485 interface are recommended in the connection cable. 4

6.1.2. Communication pin assignment: Connector COM Pin Out Function RS232 Pin 1 Pin 2 Pin 4 Pin 6 Pin 8 GND Tx RTS Rx Table 3.1: Pin Configuration RS232 Connector COM Pin Out Pin 3 Pin 5 Pin 7 Function RS485 B (+/Z) A (-/Y) Termination B Table 3.2: Pin Configuration RS485 Note: ICX-CMTM units have built in 120 Ohm Termination resistor. Termination must be activated if the unit is at the end of network (end of RS485 cable). To activate Termination, bridge between Pin 5 A (-/Y) and Pin 7 (Termination). 6.1.3. Example of RS232 connection: 6 7 8 9 1 2 3 4 5 Rx Tx GND Rx Tx Shield 5

120 Ω Example of RS485 connection: Termination jumper A (-/Y) B (+/Z) A (-/Y) B (+/Z) GND GND 6.3. CAN port Currently not used. 6.4. Micro USB port Currently not used. 7. Button Internal button to restoring factory settings. Externally accessible with a pointed object such as a straightened-out paper clip. 8. RTC Real-time clock. It is powered with high capacity capacitor. The clock can continue to run up 3 weeks without external power. icex synchronizes the RTC time with the server on power up and every 24 hours. 9. I/O icex model R10.U with I/O has 8 analogs input current / voltage and 8 discrete 24 volt DC input / output. 9.1. I/O pin assignment: 6

9.2. Analog inputs in detail: GND for Analog In is galvanic isolated from GND for Digital I/O. The Analog I/O signals are not galvanic isolated among themselves. Technical data: Analog Inputs: voltage input 0-10.1V or current input 0-25mA. Any analog input can be used as a voltage input or current input. Analog input A/D is 11 bits. The whole range is 0 2047. 9.3. Digital I/O in detail: Digital I/O x can be used as an input or output. By using as an output, the signal status can be read back via the input function. In both applications, the signals refer to "GND for digital I/O" which is galvanic isolated from "GND for analog in". The digital I/O x signals are not galvanic isolated among themselves. Technical data: Digital Inputs: Sink, 24 V DC type 5 ma; The nominal value for TRUE: 15 V DC min The nominal value for FALSE: 5 V DC max Digital Outputs: Transistor, 24 V DC, max 500 ma Short-circuit and overload resistant. 7

9.4. ICX-CMTM-R10.0U I/O wiring diagram 8