VP1-250X USER S MANUAL

Similar documents
USER S MANUAL. XVPX-9756 Single-Slot 3U VPX bus Bootable SATA/SAS Drive Module

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz Ca Fax Est

Hardware Reference Guide For Thin Clients

3/4 U CPCI Serial Case System

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

3+1 U CPCI Serial System

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SAS e PCI Express to 12Gb/s SAS Host Bus Adapter

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

PMC494 10BaseT to 10Base2 PMC Media Converter

HP Eight-Port SAS/SATA RAID Host Bus Adapter

Hardware Reference Guide HP Compaq t5000 Thin Client

General Purpose Chassis for PXI and CompactPCI

SGI InfiniteStorage 120

Thin clients JC500X - 1 Reference guide

CPCI System Subrack 1 U

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

BPN-SAS3-743A Backplane USER'S GUIDE

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

PCI 2 Axis Servo Card

iconverter 2-Module Power Chassis

Installation Instructions

EOS-6000 Series Optical A/B Switch User Manual DC Version

HP ProLiant NC1020 Cu Gigabit Server Adapter 32 PCI Single Port User Guide. June 2007 (Second Edition) Part Number B

Metro-Optical Transport Access Nodes

CSE-M14T Mobile Rack USER'S GUIDE

Installation Instructions

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Agilent OBSAI Protocol Tester

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

PCI 2 Axis Servo Card

Agilent N1022A Active Probe Adapter User Guide

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

TRC-190 User s Manual

ewon Flexy PSTN Extension Card FLA 3501

BPN-SAS-F424-A6 Backplane USER'S GUIDE

Customer Replacement Procedure

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

HP BladeSystem c-class Enclosure Troubleshooting Guide

SECTION N -- ELECTROSTATIC DISCHARGE (ESD)

FLEX Ex Spring Clamp Terminal Base

VME64x System Subrack 1 U

IPC-611 Series 4U Rackmount Industrial Chassis User Manual

2.5 SATA III MLC SSD

MC 11 EB-2 Power supply cabinet with external bus, AC version

Model 2380 Rack-Mount Kit

TPX-4 PCI-Expansion Subsystem Installation Manual

User Manual PCM Port CAN-Bus Mini PCIe Module with Isolation Protection

PMX09 DATA SHEET FEATURES A PORTABLE 9-SLOT 3U PXI EXPRESS CHASSIS WITH INTEGRATED DISPLAY AND KEYBOARD

CPCI System Subrack 3 U

BPN-SAS3-F418-B6N4 Backplane USER'S GUIDE

Digital ac/dc (24V) Input Module

Customer Replacement Procedure

ewon Flexy PSTN Extension Card FLA P3501 Installation Guide

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz, Calif Fax Est.

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est

HP Ethernet 1Gb 2-port 332T Adapter User Guide

MIC-3002A Series. 3U 6-slot CompactPCI Enclosures with Rear I/O and 6" LCD. User Manual

HP Moonshot Switch User and Maintenance Guide

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

Perle MCR200 Installation Guide

ewon Flexy 2 Serial Ports Ext. Card FLA 3301

CPCI System Subrack 3 U

DYNAMIC ENGINEERING. 150 DuBois St. #3, Santa Cruz Ca Fax Est

A0750 AC-DC POWER MODULE

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

VPX Test Platform User Manual

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

SATA III MLC CFast Card

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection

I/O SIGNAL CONDITIONER

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Dell OptiPlex 7460 All-in-One. Intel Optane card installation guide

Customer Upgrade Procedure

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Installation Instructions

Resolver to Digital Expansion Board

VME64x System Subrack 8 U

SATA III MLC CFast Card

ArmorPoint I/O Field Potential Distributor, Series A

Customer Replacement Procedure

CP-RIO6-923 USER GUIDE. 6U CompactPCI Rear-Panel I/O Board. CP-RIO6-923 Manual ID 1.1 Revision Index 19 September, 2007 Date of Issue

Dell EMC Storage MD1280 Enclosure Owner's Manual

Enhanced Mini-Chansim Model VCS-232

OptiPlex XE3 Tower. Remote Power Switch Installation Guide. Regulatory Model: D18M Regulatory Type: D18M005

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

HP NetServer E 800 Installation Guide

MLC 2.5 SATA III SSD

Model 2380 Rack-Mount Kit

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

BPN-NVMe3-216N-S4 Backplane USER'S GUIDE 1.0

User Manual EBPC Embedded Industrial Computer Chassis for 3.5 Biscuit SBCs

Stand-Alone-Relay S-A-Relay

NI PXI-1042 Series Power Supply Shuttle

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature

OPERATIONS MANUAL PCM-DOC

Transcription:

VP1-250X Single-Slot 3U Open-VPX Rugged SATA/SAS Disk Module USER S MANUAL Copyright 2016 Phoenix International Systems, Inc. All Rights Reserved

Table of Contents Introduction Features Part Number Key Module and Backplane Profiles Handling Installation Functional Block Diagram Module Layout Option Configuration Connector Pin Definitions Specifications 3 3 3 3 4 4 5 6 6 7 9 Warranty and Support 10 Disclaimer The information contained within this document has been carefully checked and is believed to be entirely reliable and consistent with the product that it describes. However, no responsibility is assumed for inaccuracies. Nor does Phoenix International assume any liability arising out of the application or use of any product or circuit described herein. Phoenix International reserves the right to make changes to any product and product documentation in an effort to improve performance, reliability or design. Furthermore, the information contained herein is of a proprietary nature and is not to be reproduced without prior written consent of Phoenix International. VP1-250X User s Manual - 2 - Revision E, September 2016

Introduction Phoenix International s VP1-250X Serial Attached SCSI (SAS)/Serial ATA (SATA) based VPX blade delivers high capacity, high performance data storage for military, aerospace and industrial applications requiring rugged, secure and durable mass data storage. The VP1-250X is a 3U VPX storage module that can support either a rotating or solid-state hard drive. When used with supporting media, the VP1-250X supports the purge input signal to destroy the media or the Zeroize that performs a DOD approved erasure of the media. The VP1-250Xs outstanding performance and versatility is enabled by Phoenix Internationals state-of-the-art technology which provides very high transfer and I/O rates, enhanced endurance and maximum data integrity. Features Supports SAS or SATA Solid State Disk or Hard Disk Devices Conduction, REDI Conduction and Air Cooled Configurations Front Panel Drive Activity Indicator Remote Drive Activity Indicator Up to 80,000 Feet Operational Altitude Operational Temperature from -40 to 85 C Meets Military and IRIG 106-07 Declassification Standards Optional AES 256 Encryption Support for Purge, Zeroize, Triggered Write Protect, and Other Optional Features Part Number Key Module and Backplane Profile The VP1-250X is compatible with the following VITA profile: MOD3-STO-1U-16.5.1-2 VP1-250X User s Manual - 3 - Revision E, September 2016

Handling To prevent damaging the module, be aware of the precautions you need to follow when handling or installing the module. A discharge of static electricity from a finger or other conductor may damage static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: - Avoid hand contact by transporting and storing products in static-safe containers. - Keep electrostatic-sensitive parts in their containers until they arrive at static-protected workstations. - Place parts in a static-protected area before removing them from their containers. - Avoid touching pins, leads, or circuitry. - Always be properly grounded when touching a static-sensitive component or assembly. Grounding methods to prevent electrostatic discharge Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: - Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 Megaohm (± 10 percent) resistance in the ground cords. To provide proper ground, wear the strap snug against the skin. - Use heel straps, toe straps or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. - Use conductive field service tools. - Use a portable field service kit with a folding static-dissipating work mat. Installation Ensure that all power is removed from the VPX backplane before inserting the module. Prior to inserting the VP1-250X into the card cage, it is necessary to verify the slot the module will be inserted into is compatible with the module. VPX modules are typically keyed to prevent the insertion of a module into the wrong card cage slot. The VP1-250X utilizes two guide modules with keying. In the standard configuration both guide modules are not keyed. Caution must be used to ensure the module is not inserted into a slot that will cause damage to either the module, the backplane, or any other device attached to the system. Guide module keying is available with no key, 0, 45, 90, 270, and 315. Considerations for airflow provided to the module are important. Ensure that proper airflow is provided to air-cooled modules. Conduction cooled modules should only be used in a properly configured conduction cooled card cage. Operation of a conduction cooled VPX module in an air cooled environment can result in overheating of the storage device. VP1-250X User s Manual - 4 - Revision E, September 2016

Functional Block Diagram VP1-250X User s Manual - 5 - Revision E, September 2016

Module Layout Option Configuration Purge/Zeroize, PCB location P3: The Purge and Zeroize connections are provide to allow for triggering optional features of an attached drive (dependent on drive capabilities). These connections, which are routed to the VPX P1 connector, are not limited to these functions. They can be utilized to take advantage of other drive dependent options such as write protect, or used for custom sensor or warning circuits. Safety Ground, Jumpers JP1 & JP2: By installing jumpers at locations JP1 and JP2 the ground plane of the VPX module will be connected to the VPX key guides. This allows for the option of connecting the VPX module ground plane directly to the VPX chassis ground plane. VP1-250X User s Manual - 6 - Revision E, September 2016

Connector Pin Definitions VPX Connector P0: P0 A B C D E F G 1 NC NC NC NC +12V +12V +12V 2 NC NC NC NC +12V +12V +12V 3 +5V +5V +5V NC +5V +5V +5V 4 NC NC NC NC NC 5 NC NC NC NC NC 6 NC NC NC NC NC 7 NC NC NC NC NC 8 NC NC NC NC VPX Connector P1: P1 A B C D E F G 1 NC NC NC NC NC 2 NC NC NC 3 NC NC NC NC NC 4 NC NC NC 5 NC NC NC NC NC 6 NC NC NC 7 NC NC NC NC NC 8 NC NC NC 9 RXP0_P RXP0_N TXP0_P TXP0_N DRIVE_LED 10 NC NC NC 11 NC NC NC NC PURGE 12 NC NC NC 13 RXS0_P RXS0_N TXS0_P TXS0_N ZEROIZE 14 NC NC NC 15 NC NC NC NC NC 16 NC NC NC Connector P3: Pin Description 1 Purge 2 Zeroize 3 Ground VP1-250X User s Manual - 7 - Revision E, September 2016

SAS/SATA Connector J1: SAS/SATA Signal SAS/SATA Power Pin A Pin A S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 RP+ RP- TP- TP+ RS+ RS- TS- TS+ P1 NC P2 NC P3 NC P4 P5 P6 P7 +5V P8 +5V P9 +5V P10 P11 DRV_LED P12 P13 +12V P14 +12V P15 +12V VP1-250X User s Manual - 8 - Revision E, September 2016

Specifications Physical: Form Factor: 3U VPX bus 6.30" (160mm), 3.94" (100.0mm) Module Interface: SATA or SAS Flammability: UL94V-0 PCB made in the USA by a UL recognized manufacturer Environmental: Air Cooled Temperature: 0 to 55 C (Air flow requirement as measured to be greater than 200 LFM) Conduction Cooled Temperature: -40 to 85 C (Module MUST operate in a fully installed Conduction Cooled rack) Conduction-cooled with REDI (Vita 48) covers Temperature: -40 to 85 C (Module MUST operate in a fully installed Conduction Cooled, REDI cover rack) Vibration: 1g2/Hz, 15Hz-2KHz random; 10g Peak, 15Hz-2KHz sine Shock: 20Gs each axis, 40g Peak, Sawtooth @ 11mSec Storage Temperature: -55 to 105 C Relative Humidity: 5 to 95 percent, noncondensing MTBF: 24,800,000 Hours @ 25 C (without drive). * Must use a Solid State drive capable of temperature range and shock and vibration. Compliance Specifications: The VP1-250X SATA/SAS Drive Module is designed to meet CE Emissions specification EN 55022, CE Immunity specification EN 50082-2 and FCC 47 CFR, Part 15, Class A when tested in a shielded enclosure. Meets VITA 46.0, 48.2 and 65: VPX System Specifications and Practices. VP1-250X User s Manual - 9 - Revision E, September 2016

Warranty and Support Warranty Statement Phoenix International VPX products come with a return-to-factory warranty which covers defects in materials and workmanship for a period of three years from the date of product shipment to the customer, provided the product is unmodified and has been subject to normal and proper use. Warranty on non-phoenix International manufactured devices incorporated into Phoenix VPX products is restricted to that provided by their manufacturer only. If You Have a Problem If you are having a problem with a Phoenix International product, you should call our main number, (714) 283-4800, and ask for Customer Service. Please be prepared to supply as much detail as you can concerning the nature of the problem and the conditions in which the problem appeared. Obtaining an RMA In order to return the product for repair, the following steps are necessary: 1. Obtain a Return Materials Authorization number (RMA#) from Phoenix International Customer Service. 2. Ship the product prepaid to the designated repair point. 3. Provide with the product a written description of the claimed defect. Shipping the Product Any product returned to Phoenix International should be in its original shipping carton if possible. Otherwise the product should be carefully packaged in a conductive packing material and placed in a cushioned corrugated carton suitable for shipping. Please mark the shipping label with the RMA number and return it to: Phoenix International 812 W. Southern Avenue Orange, CA., 92865 Attn: Customer Service Department RMA #: VP1-250X User s Manual - 10 - Revision E, September 2016