Digital Image Processing

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Ch. 4 Physical Principles of CT

A closer look at CT scanning

Computer-Tomography II: Image reconstruction and applications

Some reference material

Image Acquisition Systems

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Introduction to Biomedical Imaging

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

MEDICAL IMAGING 2nd Part Computed Tomography

AIDR 3D Iterative Reconstruction:

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Medical Image Processing: Image Reconstruction and 3D Renderings

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Philips SPECT/CT Systems

AAPM Standard of Practice: CT Protocol Review Physicist

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

Biomedical Imaging. Computed Tomography. Patrícia Figueiredo IST

Cardiac Dual Energy CT: Technique

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

Fundamentals of CT imaging

CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

Effect of Scattering on the Image. Reducing Compton Scatter with a Grid

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013

Optimisation of Toshiba Aquilion ONE Volume Imaging

Equipment Specification

Tomographic Reconstruction

CT vs. VolumeScope: image quality and dose comparison

ML reconstruction for CT

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

Solid Capabilities Are Built Into the Supria Plus. Putting You On The Path of High Quality, Cost-Effective CT Scanning

MEDICAL IMAGING 2nd Part Computed Tomography

INTERNATIONAL STANDARD

LAB DEMONSTRATION COMPUTED TOMOGRAPHY USING DESKCAT Lab Manual: 0

Fits you like no other

CT: Physics Principles & Equipment Design

The Near Future in Cardiac CT Image Reconstruction

ImPACT. CT dosimetry and a data base for CTDI values. EFOMP Workshop at ECR Imaging Performance Assessment of CT Scanners

Background. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE /

Fujifilm DR Solution. FDR AcSelerate. The new pinnacle in diagnostic imaging from Fujifilm ISS. CsI. Dynamic Visualization. Technology.

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

BME I5000: Biomedical Imaging

Brilliance CT Big Bore.

CT Basics: Image Processing and Reconstruction Module 4

[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Interaction map. X-Ray Computed Tomography Measures Tissue Properties from Macro to Micro. Outline

PRODUCT DATA. Advanced 128

icatvision Quick Reference

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

DUAL energy X-ray radiography [1] can be used to separate

Spectral analysis of non-stationary CT noise

FINDING THE TRUE EDGE IN CTA

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

Computed Tomography Imaging: CT Protocol Management. Caveat 8/3/2017

Fits you like no other

Financial disclosure. Onboard imaging modality for IGRT

Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

Carestream s 2 nd Generation Metal Artifact Reduction Software (CMAR 2)

Medical Imaging BMEN Spring 2016

Micro-CT Methodology Hasan Alsaid, PhD

X-ray Computed Tomography: Principle and Recent Advancements

Reduction of Metal Artifacts in Computed Tomographies for the Planning and Simulation of Radiation Therapy

Digital Scatter Removal in Mammography to enable Patient Dose Reduction

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Modifications for P551 Fall 2014

O-ARM IMAGING SYSTEM TECHNICAL SPECIFICATION GUIDE

First CT Scanner. How it Works. Contemporary CT. Before and After CT. Computer Tomography: How It Works. Medical Imaging and Pattern Recognition

Computed Tomography. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Sep 26th/Oct 3rd, 2016

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

GPU implementation for rapid iterative image reconstruction algorithm

DUE to beam polychromacity in CT and the energy dependence

Computer-Tomography I: Principles, History, Technology

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

Annexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

Assessment of 3D performance metrics. X-ray based Volumetric imaging systems: Fourier-based imaging metrics. The MTF in CT

Artifacts in Spiral X-ray CT Scanners: Problems and Solutions

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

1970 Projection Radiography 2D projection of 3D anatomy

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

Introduction to Positron Emission Tomography

4/19/2016. Deborah Thames R.T. (R)(M)(QM) Theory & Technology and advancement in 3D imaging DBT

Corso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET

Basics of treatment planning II

Lecture 6: Medical imaging and image-guided interventions

The effects of metal on size specific dose estimation (SSDE) in CT : a phantom study

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

SCENARIA 64-Slice CT Putting Advanced CT Within Reach.

MDCT and 3D Workstations

Computational Medical Imaging Analysis

As fl exible as your care requires

Transcription:

Day 2 part 2 RADIOLOGY AND DIAGNOSTIC IMAGING Dr hab. Zbigniew Serafin, MD, PhD serafin@cm.umk.pl

2

3

4

5 CT technique

CT technique 6 CT system Kanal K: RSNA/AAPM web module: CT Systems & CT Image Quality and Protocols

CT technique 7 CT system stationary x-ray tube, rotating multi-row panel of detectors Kanal K: RSNA/AAPM web module: CT Systems & CT Image Quality and Protocols

CT technique 8 CT system stationary x-ray tube, rotating multi-row panel of detectors advanced x-ray tube technology: instant current up to 500 ma over 5-40 s large heat capacity and fast cooling rates mechanical stress due to rotation up to 13 G

CT technique 9 CT system each detector, along with the focal spot of x-ray tube, defines a ray the intensity of the beam within each ray depends on the total attenuation of the tissue through which it passes. the data acquired during a CT scan consist of a series of views for each view, all detectors make intensity measurements simultaneously over a short period of time. The set of simultaneous measurements constitutes a profile/projection

CT technique 10 CT system c.f. Kalender WA, Computed Tomography, Second Edition, pg. 26, 2005

CT technique 11 CT system a CT reconstruction algorithm is used to produce the CT image filtered back projection is most widely used in clinical CT scanners 11

CT technique 12 CT scanning two basic modes of acquisition

CT technique 13 CT scanning acquisition parameters determine production of scan data sets reconstruction parameters determine presentation of the data single slice scanners multislice scanners, multi-detector row scanners (MDCT)

CT technique 14 CT scanning acquisition parameters tube potential (80-140 kvp) voltage between cathode and anode; higher potential accelerates electrons more, giving x-rays more energy tube current (20-500 ma) current following through cathode; larger current produces more electrons and greated x-ray beam intensity scan time (0.3-4 s) time of x-ray production during one rotation; longer scan time incresases x-ray count slice width (0.5-10 mm) slice thickness in z-axis beam filtration beam shaping filter optimized for body parts helical pitch (0.5-2)

CT technique 15 CT scanning acquisition parameters pitch = table movement per rotation (mm) / beam width (mm)

CT technique 16 CT scanning reconstruction parameters helical interoplation reduces artifacts due to changing structure in z-axis interpolation averages dataon either side of the reconstruction position to estimate projection at that point

CT technique 17 EXERCISE give the effects in patient dose, scan time, and image quality when using a pitch <1 a pitch > 1

CT technique 18 image processing pixel (picture element) is the basic 2D element of the digital image each pixel displays brightness information concerning the patient s anatomy that is located in the corresponding voxel (volume element) the pixel width and height are equal to the voxel width and height the voxel has a third dimension that represents the slice thickness of the CT scan

CT technique 19 CT scanning reconstruction parameters reconstruction field of view (FOV, 10-50 cm) total image size in x and y directions reconstruction matrix (usually 512x512) image resolution convolution kernel / reconstruction filter variety of reconstruction settings emphasize different characteristics in the CT image, offering tradeoffs between spatial resolution and noise bone algorithm - fine detail but with increased noise soft tissue filters - smoothing, which decreases image noise but also decreases spatial resolution

CT technique 20 CT scanning convolution kernels

CT technique 21 CT scanning convolution kernels

CT technique 22 CT scanning convolution kernels

CT technique 23 CT scanning reconstruction parameters isotropic resolution = all sides of the voxel have equal dimensions, which results in better reconstructions and lower artifacts in 3D flexible image reconstruction data from more than one detector row can be summed to reconstruct wider slices: native acquisition 256 slices / 0,625 mm standard head 32 slices / 5 mm thin slice head 160 slices / 1 mm

CT technique 24 image processing CT reconstruction process results in a 2D matrix of floating point numbers in the computer which range from near 0.0 to 1.0 these numbers correspond to the average linear attenuation coefficient of the tissue contained in each voxel The CT images are normalized and truncated to integer values that encompass 4096 values, between -1000 and 3095 (typically) CT numbers are rescaled linear attenuation coefficients

CT technique 25 CT numbers = Hounsfield Units Kalender WA, Computed Tomography, Second Edition, pg. 31, 2005

CT technique 26 image processing CT numbers and hence CT images derive their contrast mainly from the physical properties of tissue that influence Compton scatter the linear attenuation coefficient tracks linearly with density of tissue and plays the dominant role in forming contrast in medical CT CT numbers are quantitative, pulmonary nodules that are calcified are typically benign, and amount of calcification can be determined from the mean CT number of the nodule CT is also quantitative in terms of linear dimensions and can be used to accurately access tumor volume or lesion diameter

CT technique 27 EXERCISE Why do CT images offer higher contrast than plain films?

CT technique 28 EXERCISE Why do CT images offer higher contrast than plain films? CT images offer high contrast due to the imaging principle where the contrast depends on local differences in attenuation unlike conventional radiography where signal is a sum of all signal contributions along a ray from x-ray source Kalender WA, Computed Tomography, Second Edition, pg. 31, 2005

CT technique 29 image processing computer monitors and laser imagers for printing have about 8 bits of display fidelity (2 8 =256) the 12-bit CT images must be reduced to 8 bits to accommodate most image display hardware the window width (W) determines the contrast of the image, with narrower windows resulting in greater contrast the level (L) is the CT number at the center of the window

CT technique 30 image processing window settings c.f. Kalender WA, Computed Tomography, Second Edition, pg. 32, 2005

CT technique 31 image processing window settings

CT technique 32 image processing window settings

CT technique 33 image processing window settings

CT technique 34 image processing multiplanar reformatting (MPR) is a method for generating coronal, sagittal, or oblique images from the original axial image data the in-plane pixel dimensions approximate the x-y axis resolution, but the slice thickness limits the z-axis resolution

CT technique 35 image processing multiplanar reformatting (MPR)

CT technique 36 image processing oblique reformatting is quite similar to sagittal or coronal reformatting, except that the CT voxels in the stack are sampled along an axis that is tilted from either the x or y planes.

CT technique 37 image processing oblique reformatting

CT technique 38 image processing curved reformatting

CT technique 39 image processing curved reformatting

CT technique 40 image processing reformatting maximum-intensity projection (MIP) minimum-intensity projection (miniip)

CT technique 41 image processing

CT technique 42 image processing adjustable slab thickness

CT technique 43 image processing adjustable slab thickness

CT technique 44 image processing volume rendering

CT technique 45 image processing surface rendering, virtual endoscopy

46 CT basic applications

CT basic applications 47 brain imaging stroke

CT basic applications 48 brain imaging injury, tumor, infection

CT basic applications 49 spine injury, degenarive disease

CT basic applications 50 chest injury, cancer,

CT basic applications 51 abdomen injury, cancer

CT basic applications 52 vascular imaging aorta, carotids

CT basic applications 53 vascular imaging renal graft

CT basic applications 54 bone injury

CT contraindications 55 contraindications to x-ray imaging to iodinated contrast media inability to hold on the exam (dyspnea, tremor, children) lacking indications

CT complications 56 complications x-rays contrast media

57 CT advanced applications

CT advanced applications 58 perfusion CT perfusion imaging rbf rbv TTP MTT PS

59 CT technique

CT advanced applications 60 cardiac CT

61 CT advanced applications

62 CT advanced applications

CT advanced applications 63 0% 10% 20% 30% 40% 50% 60% 70% 80% 90%

64 CT advanced applications

65 CT advanced applications

CT advanced applications 66 wall motion wall thickenning ED wall thickness

CT advanced applications 67 advances in CT technology wide detector panels z-flying focal spot dual-source CT dual-energy CT PET-CT

CT advanced applications 68 advances in CT technology wide detector panels z-flying focal spot dual-source CT dual-energy CT PET-CT

CT advanced applications 69 advances in CT technology wide detector panels z-flying focal spot dual-source CT dual-energy CT PET-CT

CT advanced applications 70 advances in CT technology wide detector panels z-flying focal spot dual-source CT dual-energy CT PET-CT

CT advanced applications 71 advances in CT technology wide detector panels z-flying focal spot dual-source CT dual-energy CT PET-CT

CT advanced applications 72 advances in CT technology wide detector panels z-flying focal spot dual-source CT dual-energy CT PET-CT Kalender WA, Computed Tomography, Second Edition, pg. 74, 2005 72

CT advanced applications 73 CT fluoroscopy the scanner provides pseudo-real time tomographic images that are most commonly used for guidance during biopsies the CT image is constantly updated to include the latest projection data images are displayed on a monitor in the cine mode low tube currents (20 to 50 ma) used to minimize dose

74 CT artifacts

CT artifacts 75 CT artifacts physics-based artifacts result from the physical processes involved in the acquisition of CT data patient-based artifacts caused by such factors as patient movement or the presence of metallic materials in or on the patient scanner-based artifacts result from imperfections in scanner function Barrett JF, et al: Artifacts in CT: Recognition and Avoidance. RadioGraphics 2004.

CT artifacts 76 physics-based artifacts beam hardening x-ray beam is composed of individual photons with a range of energies. As the beam passes through an object, it becomes harder, that is to say its mean energy increases, because the lower-energy photons are absorbed more rapidly than the higherenergy photons

CT artifacts 77 physics-based artifacts partial volume artifacts caused by a mixture of tissues with very different attenuation coefficients within any given voxel, resulting in tissue shading

CT artifacts 78 physics-based artifacts photon starvation can occur in highly attenuating areas such as the shoulders. When the x-ray beam is traveling horizontally, the attenuation is greatest and insufficient photons reach the detectors. The result is that very noisy projections are produced at these tube angulations. The reconstruction process has the effect of greatly magnifying the noise, resulting in horizontal streaks in the image.

CT artifacts 79 patient-based artifacts metallic artifacts severe streaking artifacts that occur because the density of the metal is beyond the normal range that can be handled by the computer, resulting in incomplete attenuation profiles

CT artifacts 80 patient-based artifacts motion artifacts patient motion can cause misregistration artifacts, which usually appear as shading or streaking in the reconstructed image

CT artifacts 81 scanner-based artifacts ring artifacts the detector gives a consistently erroneous reading at each angular position when one of the detectors is out of calibration

82 CT radiation dose

CT radiation dose 83 rationale 1 person / 1000 would develop cancer from 10 msv (abdomen CT) Committee to assess health risks from exposure to low levels of ionizing radiation. Washington DC

CT radiation dose 84 basics beam energy 120-140 kvp vs. low-dose imaging photon fluence radiation dose is directly proportional to the milliampere-seconds value Mc Nitt-Gray MF: AAPM/RSNA Physics Tutorial for Residents: Topics in CT Radiation Dose in CT. RadioGraphics 2002.

CT radiation dose 85 basics pitch value (table distance traveled in one 360 rotation/total collimated width of the x-ray beam) has a direct influence on patient radiation dose. As pitch increases, the time that any one point in space spends in the x-ray beam is decreased. beam collimation Mc Nitt-Gray MF: AAPM/RSNA Physics Tutorial for Residents: Topics in CT Radiation Dose in CT. RadioGraphics 2002.

CT radiation dose 86 basics patient size when the same technical parameters are used, the appropriate index shows that the smaller object always absorbs the higher dose and that the difference is at least a factor of two z-axis coverage scanner dose-reducing systems (tube current modulation, automatic mas settings, iteative reconstructions) Lee CH, et al.: Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to Practice. RadioGraphics 2008.

CT radiation dose 87 measures weighted CTDI x-ray beam often passes directly into the entire surface of the patient s body primary x-ray beam contains the most photons and is most attenuated by the patient tissue energy delivered to the patient is higher at the skin surface than in the center of the body, even though the x-ray beams from all the way around the gantry pass through the center of the body.

CT radiation dose 88 measures volume CTDI CTDI adjusted for pitch (the gap or overlap of the helical pattern of radiation) = CTDI w divided by the pitch scan with a pitch less than 1 would therefore have a CTDI vol value larger than the CTDI w value scans with a pitch greater than 1 would have a CTDI vol value smaller than the CTDI w value

CT radiation dose 89 measures dose-length product DLP is calculated to account for the differences in the scan extent for a CT examination the risk of radiation-induced damage to patient tissues increases with the volume of body scanned DLP is calculated by multiplying CTDI vol in Gy by the scan extent in cm

CT radiation dose 90 measures kvp not only controls the image contrast but also controls the amount of penetration that the x-ray beam will have as it traverses the patient 80 kvp 120 kvp 140 kvp image contrast best intermediate poor noise most average least penetration least average most patient dose lowest intermediate highest

CT radiation dose 91 measures kvp not only controls the image contrast but also controls the amount of penetration that the x-ray beam will have as it traverses the patient 120 kvp 140 kvp

CT radiation dose 92 measures kvp not only controls the image contrast but also controls the amount of penetration that the x-ray beam will have as it traverses the patient mas CTDI w head CTDI w body 100 13 mgy 6 mgy 200 26 mgy 12 mgy 300 40 mgy 18 mgy 400 53 mgy 23 mgy

CT radiation dose 93 doses Lee CH, et al.: Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to Practice. RadioGraphics 2008.

CT radiation dose 94 recommendations Patient size relative dose more for smaller patients (Am Coll Radiol) pediatric abdomen CT (5 yr old) < 25 mgy adult abdomen CT < 30 mgy FDA notice: for pediatric and small patients reduce tube ma (current) increase pitch develop ma settings based on patient weight or diameter and body region reduce number of multiple scans without contrast eliminate inappropriate referrals for CT

CT radiation dose 95 trade-offs decrease ma or current increase noise increase pitch increase volume averaging increase axial increment introduce gaps eff. dose (msv) no. of chest x-rays period of background radiation chest x-ray 0.1 1 12 d mmg 0.4 4 1.6 mo abdomen x-ray 0.7 7 3 mo chest CT 5-7 50-70 1.6-2.3 y abdomen CT 8-11 80-110 2.6-3.6 y

CT radiation dose 96 EXERCISE How to reduce the patient dose without decreasing image quality?