Re-Flashing Your CDM-760 Advanced High-Speed Trunking Modem

Similar documents
I. Introduction: About Firmware Files, Naming, Versions, and Formats

I. Introduction: About Firmware Files, Naming, Versions, and Formats

Firmware Upgrade Wizard v A Technical Guide

1 Getting and Extracting the Upgrader

Enabling Your Personal Web Page on the SacLink

Release Notes. Dell SonicWALL Security firmware is supported on the following appliances: Dell SonicWALL Security 200

These tasks can now be performed by a special program called FTP clients.

Firmware Download Anybus X-gateway Modbus-TCP

1 Getting and Extracting the Upgrader

Telkom VPN-Lite router setup User Manual Billion 800VGT

1 Getting and Extracting the Upgrader

Installing the Citrix Citrix Receiver 3.3 from Citrix Web Interface for SSL VPN Users

Trimble Survey GNSS Firmware Version 4.81 (July 2013)

istartsmart 3.5 Upgrade - Installation Instructions

Xerox Security Bulletin XRX12-007

USER GUIDE. Thanks for purchasing the igate! You ll need to follow these five Configuration Steps to get your igate up and running:

Gemini Intercom Quick Start Guide

NiceLabel LMS. Installation Guide for Single Server Deployment. Rev-1702 NiceLabel

USER MANUAL. RoomWizard Administrative Console

Quick Installation Guide

File Share Navigator Online

APPLY PAGE: LOGON PAGE:

Upgrade Guide. Medtech Evolution General Practice. Version 1.9 Build (March 2018)

Release Notes Zebra TC20 and TC25 Android N LifeGuard Update 03 for NN-00-M1 (Non-GMS)

Telkom VPN-Lite router setup User Manual Billion 810VGTX

Transferring a BERNINA V8 software license

Dear Milestone Customer,

Getting Started with the SDAccel Environment on Nimbix Cloud

STIDistrict AL Rollover Procedures

Click Studios. Passwordstate. RSA SecurID Configuration

Quick Start Guide. Basic Concepts. DemoPad Designer - Quick Start Guide

Model 86A00-2 Home Theater Extender 2 (HTX2)

Upgrade Guide. Medtech Evolution Specialist. Version 1.11 Build (October 2018)

Log in with your WUSTL Key and password If you have forgotten your WUSTL Key or password, see

Release Notes. Dell SonicWALL Security BETA

Firmware Update. This utility installs an updated version of the Wireless Earbuds firmware and provides the following changes and benefits:

Imagine for MSDNAA Student SetUp Instructions

HW4 Software version 3. Device Manager and Data Logging LOG-RC Series Data Loggers

IT Essentials (ITE v6.0) Chapter 5 Exam Answers 100% 2016

DUO LINK 4 APP User Manual V- A PNY Technologies, Inc. 1. PNY Technologies, Inc. 34.

Paraben s Phone Recovery Stick

FollowMe. FollowMe. Q-Server Quick Integration Guide. Revision: 5.4 Date: 11 th June Page 1 of 26

Date: October User guide. Integration through ONVIF driver. Partner Self-test. Prepared By: Devices & Integrations Team, Milestone Systems

Interoperability between ProCurve WESM zl and HP ipaq Voice Messenger smartphone

SMART Room System for Microsoft Lync. Software configuration guide

Dolby Conference Phone Support Frequently Asked Questions

DIVAR IP 3000 Field Installation Guide

Element Creator for Enterprise Architect

Wave IP 4.5. CRMLink Desktop User Guide

XenDesktop GoToMyDesktop

SAS Hot Fix Analysis, Download and Deployment Tool

Model WM100. Product Manual

CounterSnipe Software Installation Guide Software Version 10.x.x. Initial Set-up- Note: An internet connection is required for installation.

Xilinx Answer Xilinx PCI Express DMA Drivers and Software Guide

Cntents 1 Intrductin Kit Cntents Requirements Installatin Gesture Sensr Kit Hardware and Jumper Settings De

Avigilon Control Center Server User Guide. Version 6.4

Reviewer Information Sheet for Committee Members

Medtech Evolution. Installation Guide

Online Banking for Business USER GUIDE

- International Offline. Installation Guide. For authorised Franklin Templeton use only

Max 8/16 and T1/E1 Gateway, Version FAQs

TSW-560/TSW-760/TSW ", 7", and 10.1" Touch Screens. Supplemental Guide Crestron Electronics, Inc.

UPGRADING TO DISCOVERY 2005

IMPORTING INFOSPHERE DATA ARCHITECT MODELS INFORMATION SERVER V8.7

Avocent Power Management Distribution Unit (PM PDU) Release Notes Firmware Version April 18, 2011

ROCK-POND REPORTING 2.1

VMware AirWatch Certificate Authentication for Cisco IPSec VPN

CMC Blade BIOS Profile Cloning

The screenshots/advice are based on upgrading Controller 10.1 RTM to 10.1 IF6 on Win2003

Release Notes Zebra TC20 and TC25 Android N LifeGuard Update 02 for BSP NG-00-M1 (GMS)

STANLEY Healthcare University Training & Certification Portal. Quick Reference Guide

Manual for installation and usage of the module Secure-Connect

How to Guide. DocAve Extender for MOSS 2007 and SPS Installing DocAve Extender and Configuring a Basic SharePoint to Cloud Extension

Uploading Files with Multiple Loans

Establishing two-factor authentication with FortiGate and HOTPin authentication server from Celestix Networks

Guidance for Submitting an application or Nomination in AAS Ishango Online System

Enterprise Installation

IFSP PDF Upload/Download Guidance

Application Note. Digi Connect Wi-SP Troubleshooting Guide. Digi Technical Support 10 May 2016

Launching Xacta 360 Marketplace AMI Guide June 2017

Advanced Title Search

Guidance for Applicants: Submitting an application in AAS Ishango Grants Management

Arius 3.0. Release Notes and Installation Instructions. Milliman, Inc Peachtree Road, NE Suite 1900 Atlanta, GA USA

USO RESTRITO. SNMP Agent. Functional Description and Specifications Version: 1.1 March 20, 2015

HD-MD-300-C-E/HD-MD-400-C-E HD Scaling Auto-Switchers and Extenders. Supplemental Guide Crestron Electronics, Inc.

TECHNICAL REQUIREMENTS

OASIS SUBMISSIONS FOR FLORIDA: SYSTEM FUNCTIONS

WorldShip PRE-INSTALLATION INSTRUCTIONS: INSTALLATION INSTRUCTIONS: Window (if available) Install on a Single or Workgroup Workstation

EBSCOhost User Guide Print/ /Save. Print, , Save, Notetaking, Export, and Cite Your Search Results. support.ebsco.com

Campuses that access the SFS nvision Windows-based client need to allow outbound traffic to:

Upgrading Kaltura MediaSpace TM Enterprise 1.0 to Kaltura MediaSpace TM Enterprise 2.0

CSE 361S Intro to Systems Software Lab #2

Verifone MX850 All-In-One Device: Before connecting the MX850 to your PC, the MX850 Driver CD will need to be installed.

BANNER BASICS. What is Banner? Banner Environment. My Banner. Pages. What is it? What form do you use? Steps to create a personal menu

Oracle Universal Records Management Oracle Universal Records Manager Adapter for Documentum Installation Guide

Instructions for Accessing Online Testing Resources

PAY EQUITY HEARINGS TRIBUNAL. Filing Guide. A Guide to Preparing and Filing Forms and Submissions with the Pay Equity Hearings Tribunal

Towne Information Systems, Inc. Inter-Office Correspondence

REFWORKS: STEP-BY-STEP HURST LIBRARY NORTHWEST UNIVERSITY

TRAUMACAD 2.5 PREREQUISITES

Transcription:

Re-Flashing Yur CDM-760 Advanced High-Speed Trunking Mdem I. Intrductin: Firmware Files, Naming, Versins, and Frmats Make sure t perate the CDM-760 with its latest available firmware. Befre attempting any Ethernet FTP uplad, read the imprtant nte abut cnditinal firmware upgrade requirements. The CDM-760 Advanced High Speed Trunking Mdem is factry-shipped with its latest versin f perating firmware. If yu need t update the mdem firmware, yu may dwnlad the update frm the Cmtech EF Data Web site (www.cmtechefdata.cm). Yu may als receive the firmware update archive file via e-mail frm Cmtech EF Data Prduct Supprt. Abut Firmware Numbers, File Versins, and Frmats: The Cmtech EF Data Web site catalgues its firmware update files by prduct type (e.g., ruter, mdem, etc.), the specific mdel, and ptinal hardware cnfiguratins. The CDM-760 firmware dwnlad hyperlink appears as F0020627x_Vyyy, where x is the revisin letter, and yyy is the firmware versin (e.g., V121 = Versin 1.2.1). The naming and file frmat f the firmware files fr Firmware Versins 1.2.1 and later differ frm the naming and file frmat f the firmware files prvided fr Firmware Versin 1.1.1! See Appendix A. UPDATING VERSION 1.1.1 FIRMWARE in yur user manual fr the instructins fr perfrming a Versin 1.1.1 firmware update. Abut File Archive Frmats: Cmtech EF Data prvides its dwnladable files in tw cmpressed archive frmats: *.exe (self-extracting) and *.zip (cmpressed). Sme firewalls d nt allw the dwnlad f self-extracting *.exe files. Dwnlad the *.zip file instead, and extract the firmware files frm that archive file. Use a file archiving and cmpressin applicatin such as PKZIP fr Windws, WinZip, r ZipCentral fr this task. (PKZIP fr DOS is nt supprted due t file naming cnventins.) Cmtech EF Data des nt prvide this utility prgram. Fr detailed infrmatin n handling archived files, refer t yur utility prgram Help dcumentatin. FLG-CDM760 Revisin 0 1 Re-Flashing Yur CDM-760 Advanced High-Speed Trunking Mdem

II. Prerequisites fr Perfrming the FW Ver. 1.2.1 Ethernet FTP Uplad Prcedure Befre prceeding with the CDM-760 Ethernet FTP Uplad Prcedure, assumptins are made that: Yur CDM-760 is running Firmware Versin 1.2.1 r later. Yu have nted the CDM-760 Ethernet Management IP Address using either the CDM-760 Frnt Panel r the Serial Remte Cntrl Interface. Yu may als use the CDM-760 HTTP Interface Admin Access page t review and recnfigure this IP Address as needed. The mdem remte cntrl is set t Ethernet r Ser+Ethernet cnfirm by viewing the CDM-760 Frnt Panel SELECT: Cnfiguratin Remte screen: Remte Cntrl:Ser+Ethernet Inband:Disable ( ) Yu are using a Windws-based PC running the latest versin f Java, and: The PC Ethernet prt is cnnected t the CDM-760 rear panel J4 MGMT 10/100/1000 BaseT Ethernet prt with a user-supplied hub, switch, r direct Ethernet cable cnnectin. The PC is running a cmpatible Web brwser (fr using the CDM-760 HTTP Interface). The PC serial prt is cnnected t the CDM-760 rear panel J3 REMOTE prt with a standard user serial cable. The PC is running a terminal emulatin prgram (fr using the CDM-760 Serial Interface). Yu have dwnladed (r therwise received frm Cmtech EF Data) the latest available firmware update, and yu have extracted the firmware files int an accessible temprary flder (e.g., C:\CDM760) n the User PC. See Chapter 4. UPDATING FIRMWARE in yur user manual fr further infrmatin abut the required prerequisites and preparatins fr perfrming a Versin 1.2.1 firmware update. FLG-CDM760 Revisin 0 2 Re-Flashing Yur CDM-760 Advanced High-Speed Trunking Mdem

III. Perfrming the Versin 1.2.1 Ethernet FTP Uplad Prcedure Using Windws Cmmand-Line D these steps: The CDM-760 HTTP (Web Server) Interface Admin Upgrade page is under develpment at this time, and may nt be used t update the mdem firmware images. Use Windws Cmmand-line as instructed in this sectin. Typical fr all tasks that fllw type the cmmand withut qutes, and then press Enter t execute. 1. Make nte f the active firmware image that the CDM-760 is running at present: Frm the CDM-760 Frnt Panel, use the arrw keys t view the SELECT: Utility Firmware screen. The tp line f this screen displays the running active image as ActiveImage:1 r ActiveImage:2. The FTP uplad prcedure will verwrite the standby image. 2. Use Windws Cmmand-line t transfer (FTP) the files frm the User PC t the CDM-760. First, click [Start] n the Windws taskbar, and then click the Run... icn (r, depending n Windws OS versins prir t Windws 95, click the MS-DOS Prmpt icn frm the Main Menu). Then: Fr Windws 95 r Windws 98, type cmmand. Fr any Windws OS versins later than Windws 98, type cmd r cmmand. Alternately, frm [Start], select All Prgrams > Accessries > Cmmand Prmpt. 3. Make sure yu are active in a prper wrking flder (directry) created earlier fr this task if nt, type, fr example, cd CDM760. 4. Type "ftp xxx.xxx.xxx.xxx" (where xxx.xxx.xxx.xxx is the CDM-760 Ethernet Management IP Address). 5. If Cmmand-line prmpts yu fr a user name, ne is nt required. Press Enter t cntinue. 6. The Cmmand-line prmpt changes t ftp>. Type "put F0020627.tar F0020627.tar" at the prmpt (withut qutes) t begin the file transfer. The file transfer prcess takes abut 10 minutes d nt pwer ff the PC r mdem during this time. As the upgrade prcess cntinues, the mdem frnt panel displays: Prgramming MdemApp XXX% Cmplete Lading FPGA XX f XX XXX% Cmplete FLG-CDM760 Revisin 0 3 Re-Flashing Yur CDM-760 Advanced High-Speed Trunking Mdem

7. Once the file transfers, Cmmand-line displays the uplad result, similar t: 200 Prt cmmand kay 150 Opening data cnnectin fr STOR (192.168.1.1,-9944) 226 File received OK XXXXXXX bytes in XX.XXX sec 001 Flash prgramming Successful!! ftp: XXXXXXX bytes sent in XX.XXSecnds XXX.XXXKbytes/sec. 8. Type "bye" t terminate the FTP sessin, and then clse the Cmmand-line windw. IV. Selecting the Firmware Update fr Operatin and Rebting the Mdem D these steps: 1. Make nte f the current Active Image n the SELECT: Utility Firmware screen: Firmware Images: ActiveImage: 2 Inf Select ( ) Then, n the bttm line, use the arrw keys t select Select. Press ENTER t cntinue: Current Active Image is #2 Next rebt, will use Image: #1 ( ) In rder fr the Image that was just updated t be active the next time yu rebt the mdem, yu must select that firmware image t be the Current Active Image. Use the arrw keys t select 1 r 2. (In this example, Image #1 was updated and is therefre the required chice.) Alternately, n the CDM-760 HTTP Interface Cnfiguratin Utilities page, use the Next Rebt Image drp-dwn list in the Firmware Image Cnfig sectin t select Image1 r Image2, and then click [Submit]: Once yu press ENTER n the frnt panel r click [Submit] frm the CDM-760 HTTP Interface, the mdem verifies the checksums f all the files that are being updated: Calculating checksums n selected Image. Please wait This prcess takes several minutes. D nt turn ff the mdem during this time. When the prcess is cmplete, this message displays: Selected Image has been written. Rebt Mdem r <ENTER> t Cntinue. 2. Rebt the CDM-760 using ne f these methds: Fr a hard rebt Use the rear panel ON/OFF switch (r therwise discnnect the mdem pwer surce), and then recnnent the mdem pwer. FLG-CDM760 Revisin 0 4 Re-Flashing Yur CDM-760 Advanced High-Speed Trunking Mdem

Fr a sft rebt Frm the Firmware Image Cnfig sectin f the CDM-760 HTTP Interface Cnfiguratin Utilities page, click [Rebt Mdem]: Nte that, if bting int a new image and the Tp Card Applicatin has been changed, an additinal step ccurs as the CDM-760 dwnlads t a different flash memry. This additinal uplad takes apprximately tw minutes. 3. Lg back in t the CDM-760 HTTP Interface. Once the mdem rebts, the Web brwser prmpts yu t re-enter the User Name and Passwrd in rder t resume use f the CDM-760 HTTP Interface. V. Verify that the PC-t-Mdem FTP file transfer was successful Using the CDM-760 Frnt Panel After rebt, cnfirm that the Mdem Firmware Versin that displays n the CDM-760 Frnt Panel VFD tp-level screen matches the firmware versin just laded. Yu may als review the SELECT: Utility Firmware Inf Image#1 and Image#2 screens fr detailed firmware infrmatin. Using the CDM-760 HTTP Interface Review the firmware versin n the Hme page, r the Image 1 and Image 2 flder cntents n the Status Firmware page. Using the CDM-760 Serial Interface Execute ne f these remte queries: Abbreviated <0/SWR? (displays firmware versins) Detailed <0/FRW?1 (fr Image 1) r <0/FRW?2 (fr Image 2) (displays cmplete firmware lad infrmatin) The CDM-760 is nw perating with its latest firmware. The firmware update prcess is nw cmplete. FLG-CDM760 Revisin 0 5 Re-Flashing Yur CDM-760 Advanced High-Speed Trunking Mdem

Ntes: FLG-CDM760 Revisin 0 6 Re-Flashing Yur CDM-760 Advanced High-Speed Trunking Mdem